FLOWSIC 200 Measuring Flow speed Why choose the FLOWSIC 200?

P R O D U C T I N F O R M AT I O N
FLOWSIC 200
Measuring Flow speed
A real titan – outstanding amongst
longterm tunnel monitoring devices.
In over 200 tunnels worldwide.
Why choose the FLOWSIC 200?
Minimizing your operating expenses by service intervals of up to 5 years1
■ Capable of covering very long measured section of up to 40 meters
■ Made from extremely rugged hardware – titan, stainless steel and die cast
■
Transmitter
receiver unit
Terminal box
Advanced Ultrasonic
Technology
Evaluation unit
v1
FLOWSIC2
00
v3
v4
Terminal box
1
Bus compatible 2 wire
cabling (RS
485)
PROFIBUS
v2
Analog, digital
inputs/outputs
• High-accuracy measurement at
each point across the tunnel
• High precision of air flow even
at very low velocity rates
• Additional recording of wind
directions
• Stand-alone measuring system
without any moving parts
• Simple Installation and
easy to use controls
for FLSE 200-H only
Analyzers and Process Instrumentation
8 007 537/06-2005/BW • Printed in Germany (07-2005) • Subject to change without prior notice
Selection of transceiver units
Evaluation Unit
FLSE 200-M,
Aluminium Cast Housing
c
c
FLSE 200-H,
stainl. steel housing (titan transducer)
FLSE 200-M SS;
stainless steel housing
Ultrasonic Measurement Principle
Technical Data
FLOWSIC 200
Ultrasonic transducers which act
alternately as transmitter and
receiver are installed on either side
of the tunnel at an angle of 45° to
60° to the tunnel axis. The transit
time of each sonic pulse depends on
wind speed and direction, with the
transit time being shorter at forward
and longer at reverse direction. From
the difference in transit time air
velocity can be calculated irrespective of pressure and temperature
conditions. Measurement value
processing safeguards high accuracy
and noise resistance for the measured values of the FLOWSIC 200.
Type of models:
Transceiver unit
• FLSE 200-M, Aluminium cast housing (alumin. transducer)
• FLSE 200-M SS, Stainl. Steel housing (alumin. transducer)
• FLSE 200-H, Stainless Steel housing (titanium transducer)
Evaluation Unit
Measuring value processing/output, monitor function;
cable length to TR unit: 500 m max. (with optional data
repeater 1000 m max.); larger distances on request
Commisioning and Maintenance
Parameters are set with the help of
our easy to use MEPAFLOW 200, a
window compatible software program.
The evaluation unit and the computer
are connected via a RS 232 interface.
The setting of parameters, regarding
i.e. measuring distance, range and
response time are, thanks to MEPAFLOW 200 a simple task. A manual
zero-point adjustment is no longer
necessary as this is carried out automatically by the measurement device.
During every day running operation
MEPAFLOW offers an extensive diagnosis routine. Maintenance of the
FLOWSIC 200 consits of cleaning the
transceiver unit. The maintenance
intervals of ½ to 1 year up to 5 years
are based on individual installation
conditions and the device model used.
Measurement Data
Measur. component
Velocity of air flows
Measuring Principle
Measurement of difference in ultrasonic transit time
Measuring range
–20 m/s (65 ft/sec) ... + 20 m/s (65 ft/sec); cont. variable
Accuracy
± 0.1 m/s (0.3 ft/sec); depending on calibration, installation,
flow profile, temp. and measuring distance
Measuring distance
5 … 25 m (16 … 82 ft) with FLSE 200-M and -M SS
5 … 40 m (16 … 130 ft) with FLSE-H; larger on request
Response time
1 … 300 s (sec); freely selectable
Ambient Conditions
Ambient temperature
–20…+50 °C (–4 … 120 °F)
Device Data
Maintenance intervals
½… 1 year: FLSE 200-M
1 … 5 years: FLSE 200-H depend. on application cond.
Point of Installation
• Height above road
• Angle to tunnel axis
4.2 m (14 ft) typical
45° … 60°
Displays
• Measuring values
• Status
LC-Display with 2 rows
LEDs (operation, faults, maintenance, cycles)
Power supply
90 … 140/190 … 260 V AC; 50/60 Hz;
power consumption: approx. 20 W max.
Dimensions
(L x W x D)
FLSE 200-M:
80 x 80 x 120 mm3 (260 x 260 x 393 ft3)
FLSE 200-M SS/H: 80 x 150 x 150 mm3 (260 x 492 x 492 ft3)
FLA 200:
240 x 200 x 120 mm3 (787 x 565 x 394 ft3)
Weight
FLSE 200-M:
approx. 1 kg (2.2 lb)
FLSE 200-M SS/H:approx. 2 kg (4.4 lb)
FLA 200:
approx. 1.5 kg (3.3 lb)
Protection class
IP 65/NEMA 4X
Connection/Interface via evaluation unit (customer-provided)
Signals
1 analog output: 0…20 mA, 750 Ω max. load
optional: max. 2 additional analog modules (inputs/outputs)
4 relays: 48 V AC, 1 A; electrically isolated
Interface
RS 232 for service purposes;
optional: PROFIBUS, RS 422 for data transfer
SICK MAIHAK GmbH | Analyzers and Process Instrumentation
Nimburger Str. 11 | 79276 Reute | Germany | www.sick-maihak.com
Fon +49 7641 4 69-0 | Fax 0 76 41 4 69-11 49 | [email protected]