ErP 2016/18 Euroclima informs... about ErP directive When What The European regulation EU No. 1253/2014 is implementing the Ecodesign requirements from the European directive 2009/125/EG for non-residential ventilation units. Non residential units are divided n BVU and UVU. Step 2 Step 1 01.01.2018 Abb: UVU Unidirectional Ventilation Unit 01.01.2016 Abb: BVU Bidirectional Ventilation Unit Where European Union Member States Exemptions • Unit for delivery out of European Union • Unit exclusively operating for emergency use • Unit without fan (valid if supply-/ exhaust fan or both) • Unit exclusively working with recirculating air • Unit for ships/cruise vessels (non building application) • Unit exclusively working in/with a potentially explosive atmosphere as defined in Directive 94/9/EC (valid if supply-/exhaust air or both) • Unit exclusively working in/with toxic or highly corrosive or flammable or abrasive air • Unit exclusively working with air temperature >100°C • Unit includes a heat exchanger and a heat pump for heat recovery acc. EU No. 1253/2014 article 1.1 (g) • …others (less important) y Components HRS system with thermal bypass facility BVU minimum thermal efficiency of HRS BVU HRS efficiency bonus E [W/(m³/s)] BVU all other HRS run-around coil HRS 01.01.2016 01.01.2018 mandatory mandatory 67 % 73 % 63 % 68 % all other HRS (ƞt-0,67)*3000 (ƞt-0,73)*3000 run-around coil HRS (ƞt-0,63)*3000 (ƞt-0,68)*3000 HRS system Reasonable thermal bypass method Crossflow plate heat exchanger mechanical bypass needed Double plate heat exchanger mechanical bypass needed Heat wheel control wheel rpm or stop wheel Counterflow plate heat exchanger mechanical bypass needed Accumulator stop switching between acumulator masses Heatpipe variable inclination High performance run around coil control medium flow or stop pump Run around coil control medium flow or stop pump Non residential ventilation units requirements acc. EU 1253/2014 01.01.2016 01.01.2018 Final filter pressure alarm or visual signaling all - mandatory Variable fan speed drive or multispeed drive all mandatory mandatory for reference configuration Filter correction value F [W/(m³/s)] Minimum fan efficiency ƞvu (P...electrical absorbed power including controls) Maximum internal specific fan power of ventilation components SFPint_limit [W/(m³/s)] all UVU 0 160 150 if fine (F7) filter is missing 200 190 if both filters are missing 360 340 Pabs<=30 kW 6,2[%]*In(P)+35 6,2[%]*In(P)+42 Pabs>30 kW 56,1 % 63,1 % UVU BVU HRS system with thermal bypass facility BVU minimum thermal efficiency of HRS BVU HRS efficiency bonus E [W/(m³/s)] 0 if medium (M5) filter is missing BVU run-around coil HRS all other HRS q<2m³/s 250 230 1700+E-300*qnom/2-F 1600+E-300*qnom/2-F q>=2m³/s 1400+E-F 1300+E-F q<2m³/s 1200+E-300*qnom/2-F 1100+E-300*qnom/2-F q>=2m³/s 900+E-F 800+E-F mandatory mandatory 67 % 73 % all other HRS 63 % 68 % all other HRS run around coil HRS (ƞt-0,67)*3000 (ƞt-0,73)*3000 run-around coil HRS (ƞt-0,63)*3000 (ƞt-0,68)*3000 Euroclima group factories Euroclima AG | SpA St. Lorenzner Str. | Via S. Lorenzo 36 39031 Bruneck | Brunico (BZ) ITALY Tel. +39 0474 570 900 Fax +39 0474 555 300 offi[email protected] www.euroclima.com Euroclima Apparatebau Ges.m.b.H. Arnbach 88 9920 Sillian AUSTRIA Tel. +43 (0) 48 42 66 61 -0 Fax +43 (0) 48 42 66 61 -24 [email protected] www.euroclima.com Bini Clima S.r.l. Via Giovanni a Prato, 4 38068 Rovereto ITALY Tel. +39 0464 437 232 Fax +39 0464 437 298 [email protected] www.biniclima.eu Euroclima India Pvt Ltd. Oberoi Garden Estate, B-Wing, 2nd floor 2059, Chandivali, Andheri (East) 400072 Mumbai INDIA Tel. +91 22 4015 8934 / 4022 6263 [email protected] www.euroclima.com Euroclima product catalogues ZHK 2000 CUSTOMIZED AIR HANDLING UNITS HIGHEST EFFICIENCY AIR HANDLING UNIT HIGH EFFICIENCY AIR HANDLING UNITS ETA PAC CLEANLINE EnvironmEnt friEndly and clEan concEpt solutions for comfort, hospital and industrial applications packaged energy recovery solutions for green buildings integrated accumulator, controls and dX cooling system packaged energy recovery solutions for green buildings integrated adiabatic cooling, controls and dx cooling system COMpaCt & hygieniC sOlutiOns fOr Operating theaters integrated COntrOls and dx COOling systeM ETA POOL df> > 90 % Efficiency T1/TB1 optional ASEPSIS ETA ACCU ZHK FI KITCHEN DEHUMIDIFICATION AIR HANDLING UNITS HYGIENIC AIR HANDLING UNITS HYGIENIC AIR HANDLING UNIT EXHAUST FILTRATION UNIT solutions for swimming pools fully washable & free cold bridge design for food and low temperature applications FULLY WASHABLE UNITS FOR FOOD AND BEVERAGE INDUSTRY SAINLESS STEEL; FULLY WELDED AND ROUNDED CORNERS TUNNEL solutions for KitCHEn EXHAust Air ETA MATIC DX CIRCUIT ZHK MARINE solutions for MArinE AnD offsHorE CONTROL SYSTEM FOR AIR HANDLING UNITS intelligent unit mounted controls for comfort, hospitals and industrial applications REFRIGERANT COOLING SYSTEM FOR AIR HANDLING UNITS Euroclima October 2015 Due to it’s commitment of continuous product development and improvement, Euroclima reserves the right to change specifications without notice. © Copyright by euroclima.com / fotolia.com Filter Safe® CUSTOMIZED AIR HANDLING UNITS leak-proof hepa filter frames for hospitals and clean room applications MEDICAL AIR HANDLING UNIT AIRWALL SHUT-OFF, MIXING AND BALANCING DAMPERS FOR AIR CONDITIONING APPLICATIONS
© Copyright 2026