Table 1: OSTEOTOMY and CORRESPONDING DRILLS

B T L O C K m i n i IM P L A N T
3,7 mm
2,5 mm
1 mm
11,5 mm
13,0 mm
16,0 mm
B T L O C K m i n i IM P L A N T
B T L O C K m i n i catalo g
BTLock Mini Implant line is the solution for immediate and long-term stabilization of a
removable prosthesis. The system is characterized by a wide range of options:
• Diameter
• Length
• Prosthetic parts
BTLock Mini Implants are available in 3 diameters (2 – 2,5 – 3 mm) and 3 lengths (11,5 - 13 - 16
mm). The implant length includes the machine-cut collar (1,5 mm) and BT-Tite threaded part
(mix of sandblasting and acid-etching). O-ball width 2,2 mm.
Table 1: OSTEOTOMY and CORRESPONDING DRILLS
DEPTH OF THE OSTEOTOMY
Implant 2 mm
Implant 2,5 mm
Implant 3 mm
DEPTH
DRILL 1,3
DRILL 1,8
DRILL 2,2
D1 (hard)
implant length
Ø 1,3
Ø 1,8
Ø 2,2
D2 (medium hard)
2/3 implant length
Ø 1,3
Ø 1,8
Ø 2,2
D3 (medium soft)
1/3 implant length
Ø 1,3
Ø 1,8
Ø 2,2
D4 (soft)
2-3 mm
Ø 1,3
Ø 1,8
Ø 2,2
The Mini Single is a self-threading implant made of the same titanium alloy as
the abutment. It is characterized by a BT-Tite Surface (mix of sandblasting and
acid-etching).
After the surgical stage, BTLock suggests different prosthetic options
according to the thickness of the prosthetic components and vertical
chewing dimension.
PLASTIC AND METAL CAPs with o-ring
Ø 1,3 mm for 2, 2.5, 3 mm implants
BTLOCK mini single
B T L O C K m i n i catalo g
Nylon caps and housings
BONE TYPE
One transgingival height (1 mm) and 5 prosthetic solutions are available:
• Straight and angled abutments
• Plastic housing with o-ring
• Metal housing with o-ring
• Nylon caps and metal housing
• Retaining cap
P r o s t h e t i c P r otocol
The options are the followings:
- Straight and Angled abutments;
- Nylon caps and housings (ideal for multiple levels of retention and angle
correction) available on request;
- Plastic cap with O-ring (BTICO1), specified for cases requiring minor
adjustments;
- Metal cap with O-ring (BTICO and BTIGO), specified for all remaining cases;
- Retaining cap (BTICAP).
Ø 1,8 mm for 2.5, 3 mm implants
9 mm
This implant produces a high primary stability with immediate functionality. It
should be used in anterior sites to replace laterals, cuspids and bicuspids. This
device requires a simple surgical procedure. It is possible to create the site with
or without creating a flap.
1,5 mm
2,5 mm
10 mm
11,5 mm
Each implant is packed together with the implant carrier which enables manual
positioning without contamination risks.
It is available in 4 diameters (2,5 - 3 - 3,5 - 4,2 mm) and 4 lengths (10 - 11,5 - 13
- 16 mm).
13,0 mm
16,0 mm
For attaching a straight or angled titanium abutment to the MINI Implant you must use resin cement.
Ø 2,2 mm only on hard bone and for 3 mm implants
1.
2.
SUGGESTED PROCEDURE
The BTLock Mini kit has been designed to maintain the same simplicity and user-friendliness
and contains the following instruments:
1 pilot-lancer drill (to give direction and depth) / BTISPMB;
2 twist drills to enlarge the osteotomy (in patients with dense bone) / 180B BTITW, 220 BTITW;
1 surgical ratchet wrench / BTICR;
2 ratchet extenders / BTIEC4 (short), BTIEC3 (long);
1 contra angle driver for micro motor / BTICQM *;
1 contra angle driver for micro motor (without implant carrier) / BTICQM1;
1 straight placement key / BTICCD.
BTLock MINI Implants are individually packed and gamma-ray sterilized.
Every package includes an implant carrier that allows the manual insertion without external
contamination. Static tests performed on BTLock MINI implants resulted in a breaking point
equal to 190 Ncm (2 mm diameter). Torsion testing resulted in a breaking point equal to 95
Ncm.
Note: If the torque exceeds 30 Ncm while screwing in the 2 mm MINI implant, or it exceeds
40 Ncm while screwing in the 2,5 or 3 mm MINI implants, it is advisable to unscrew the MINI
implants and widen the site with the proper drills supplied in the kit.
BTLock implants and prosthetic components have received the FDA long-term approval
(K083869 and K073458).
We advise you to insert at least four MINI
implants in order to attach an immediate
loaded removable prosthesis. If crestal
thickness is enough, we advise you to choose
the largest diameter MINI Implant (3 mm).
Before creating the osteotomy, it is advisable
to create a flap. Spin the bur at no more than
1200 Rpm’s with copious external irrigation.
To create the site for 2 mm diameter fixture,
first use 1,3 mm pilot drill. In order to insert a
2,5 mm diameter fixture use the 1,3 mm pilot
drill and then the 1,8 mm twist drill. To insert
a 3 mm diameter fixture use the 1,3 mm pilot
drill and then a 1,8 mm followed by the 2,2 mm
twist drill. In order to create the implant site
follow the instructions shown in table I.
To complete the
insertion of the
MINI
implants
located in either
the upper or
lower anterior
regions use the
long
handled
Straight
Key
(BTICCD).
To complete the insertion
of the MINI implant,
located in either the
maxilla or the mandible
use the Ratchet Wrench
(BTICR) with either the
Short Ratchet Extender
(BTIEC4) for the posterior
or the Long Ratchet
Extender (BTIEC3) for
access between adjacent
teeth.
When the osteotomy is ready, open the fixture
holder and keep the chart label for product
tracking. In the MINI implant package there
is a carrier which enables the doctor to screw
in the implant manually (no-touch delivery
carrier).
If during insertion the torque value is too
high, unscrew the implant. Then deepen
and enlarge the site using the related drill
according to table 1.
In case it is not possible to fully insert the
fixture by hand, remove the plastic cap and
screw in the implant using one of the following
devices listed below.
If placing the implant with a
micro motor and handpiece,
use the Contra Angle DriverLatch Type (BTICQM1) or the
Short Contra Angle Driver
(BTICQM). A maximum of 1520 Rmp’s is suggested. Set
the Torque control limiter
on the motor to 35 Ncm’s in
order to confirm resistance
in bone prior to immediate
load procedures.
SURGICAL PROTOCOL FOR MINI SINGLE
For chair side pickup of the caps and housings the doctor must
first mark the fixtures for the corresponding spots to be hollowed
out inside the partial/denture. Highlighting the O-ball with a
colored pen or silicone marking material is recommended.
Insert a plastic shim on the top of each fixture leaving the O-ball
of the MINI Implant exposed. This procedure keeps the cold cure
resin from infiltrating into any undercuts and also keeps the cap
in the right direction on angled implants. Next insert the caps on
the MINI Implants in the mouth.
3.
4.
Now it is necessary to use a resin bur to create holes in the
partial/denture, in order to secure the caps and housings. These
cavities must be enlarged to avoid any possible point of contact
with the metal housings while inserting the prosthesis into the
mouth. Then inject a cold cure hardening resin into the holes, seat
the prosthesis into the mouth and have the patient close with light
occlusion during the curing phase.
After polymerization gently remove the prosthesis and check that
the O-rings or caps are secured within the metal housings. Trim
away any flash, fill any voids and check the patient for proper
occlusion.
Equilibrate as needed.
Placing the Mini Single
is a minimally invasive
procedure.
Prior to creating the
osteotomy the surgeon
can choose whether or
not to open a flap. Use
the 1,3 mm pilot-lancer
drill (BTISPMB) to pierce
through the tissue and
create the initial osteotomy.
To complete the insertion of the Mini Single use the straight key
(BTICCD), the ratchet wrench (BTICR) in conjuction with the ratchet
extender (BTIEC2), or in the last case use the contra angle driver
for micro motor (BTICQM) with the ratchet extender (BTIEC2).
Then use the 1,8 mm (180B BTITW) and 2,2 mm
(220 BTITW) twist drills to create the osteotomy
following the instructions on table 1.
Now the site is ready for the implant. The Mini
Single includes an implant carrier which avoids
any manual contamination risk.
If during the insertion the torque value is too
high, remove the carrier and screw in utilizing
one of the following devices listed below.
This picture shows a 3 mm diameter Mini Single inserted.
For best results the abutment margin should be positioned
as close to the gingiva as possible. Minor marginal
adjustment may be completed utilizing a prepping bur.
MINI single
B T L ock m i n i IM P L A N T acc e s s o r i e s
RATCHET EXTENDER
Diameter
Length
Code
25010 BTICV1
2,50 mm
10 mm
BTIEC2
250115 BTICV1
2,50 mm
11,50 mm
25013 BTICV1
2,50 mm
13 mm
25016 BTICV1
2,50 mm
16 mm
30010 BTICV1
3,00 mm
10 mm
300115 BTICV1
3,00 mm
11,50 mm
30013 BTICV1
3,00 mm
13 mm
30016 BTICV1
3,00 mm
16 mm
35010 BTICV1
3,50 mm
10 mm
Code
350115 BTICV1
3,50 mm
11,50 mm
35013 BTICV1
3,50 mm
13 mm
35016 BTICV1
3,50 mm
16 mm
42010 BTICV1
4,20 mm
10 mm
420115 BTICV1
4,20 mm
11,50 mm
42013 BTICV1
4,20 mm
13 mm
42016 BTICV1
4,20 mm
16 mm
YOUR
SMILE IS
OUR MISSION
The BTLock Mini Single kit contains the following
instruments:
1 pilot-lancer drill (to give direction and depth) /
BTISPMB;
2 twist drills to enlarge the osteotomy (patients with
dense bone) / 180B BTITW, 220 BTITW;
1 surgical ratchet wrench / BTICR;
1 ratchet extender (only for Mini Single) / BTIEC2;
1 contra angle driver for micro motor / BTICQM;
1 straight placement key / BTICCD.
Please note: measures from 3,5mmx10mm to 4,2mmx16mm
are not available for the US.
BTLock MINI Implants have been designed
to satisfy dentist and patient’s needs with a
single and unique solution.
BTLock system aims to solve any kind of
single or multiple tooth loss problem, granting
great user-friendliness and optimal functional
and aesthetic efficacy.
Patients are able to chew again, but more
importantly, they can feel comfortable with
their own teeth.
BTLock has improved the relation
among researchers, implantologists,
and patients.
Thanks to the constant information
exchange, the research activity,
and the willingness to offer really
valuable products, dentists’
experiences have been
converted into innovative and
user-friendly solutions.
BTLock International s.r.l. reserves the right to eliminate, change, and replace any product at any moment in this catalogue. Rev.2, 2013- Valid from September 1st, 2010 until new publishing
B T L O C K m i n i s i n g l e acc e s s o r i e s
B T L O C K m i n i catalo g
STRAIGHT ABUTMENTS (Titanium and Castable)
MINI
Code
Diameter
Length
200115A BTICV1
2,00 mm
11,50 mm
20013A BTICV1
2,00 mm
13,00 mm
20016A BTICV1
2,00 mm
16,00 mm
250115A BTICV1
2,50 mm
11,50 mm
2030 BTIPML
25013A BTICV1
2,50 mm
13,00 mm
25016A BTICV1
2,50 mm
16,00 mm
ANGLED ABUTMENTS (10° and 18°)
300115A BTICV1
3,00 mm
11,50 mm
30013A BTICV1
3,00 mm
13,00 mm
30016A BTICV1
3,00 mm
16,00 mm
O-RING AND HOUSINGS
BTICO1
Straight placement key
Surgical ratchet wrench
Box only: BTIMIBOX
Kit: BTIKMS
BTICCD
BTICR
Short contra angle driver
BTICQM
Ratchet extender
(only for Mini Single)
BTIEC2
1,3 mm Pilot-lancer drill
BTISPMB
1,8 mm Twist drill
180B BTITW
2,2 mm Twist drill
220 BTITW
2030A BTIPMLI
2030 BTIMCL
2030B BTIPMLI
NYLON CAPS AND HOUSINGS
BTICO
BTIGO
BTICO2OV
BTICO2OR
BTICO2
BTICO2K
BTICO2OA
ANALOGUE AND IMPRESSION COPING
TORQUE WRENCH
2030 BTIANL**
SURGICAL BOX for Mini Single
BTICAP
Please note: all abutments
are not available for the
US.
BTLock’s research
department,
implantologists,
and patients:
** Metal analogue
also available
(2030 BTIANL1)
2030 BTITLC
BTICRD
SURGICAL BOX for MINI Implants
Connections
that
change
life.
BTLock International Headquar ters
Via Madonnetta 97/c
36075 Montecchio Maggiore (VI) - ITALY
phone 0039 0444 492609
fax 0039 0444 497647
[email protected] - www.btlock.com
Box only: BTIMIBOX
MINI
IM
P
L
A
N
T
Kit: BTIKMO
* For u.s. market: on the MINI Implant kit the contra angle driver
(BTICQM) is available on request.
Straight placement key
BTICCD
Surgical ratchet wrench
BTICR
Contra angle driver
BTICQM1
Short contra angle driver
BTICQM *
Short ratchet extender
BTIEC4
Long ratchet extender
BTIEC3
1,3 mm Pilot-lancer drill
BTISPMB
1,8 mm Twist drill
180B BTITW
2,2 mm Twist drill
220 BTITW