CTS Copper System www.anvilintl.com MARCH 2014 For the most current product/pricing information on Anvil products, please visit our website at www.anvilintl.com B u i l d i n g C o n n e c t i o n s T h at L a s t For over 160 years, Anvil has worked diligently to build a strong, vibrant tradition of making connections — pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior customer service at all levels. We provide expertise and product solutions for a wide range of applications, from plumbing and mechanical, HVAC, industrial and fire protection to mining, and oil and gas. Our comprehensive line of products includes: grooved pipe couplings, grooved and plain-end fittings, valves, cast and malleable iron fittings, forged steel fittings, steel pipe nipples and couplings, pipe hangers and supports, channel and strut fittings, mining and oil field fittings, along with much more. As an additional benefit to our customers, Anvil offers a complete and comprehensive Design Services Analysis for mechanical equipment rooms, to help you determine the most effective and cost-efficient piping solutions for your pipe system. At Anvil, we believe that responsive and accessible customer support is what makes the difference between simply delivering products — and delivering solutions. Gruvlok® CTS Copper System The Gruvlok® CTS Copper System offers an installer of large diameter copper tubing an alternative to the conventional soldering and brazing. Table of Contents CTS Copper Fittings Figure 6050 – 90˚ Elbow.................. 4 Figure 6051 – 45˚ Elbow.................. 4 The introduction of the SlideLOK CTS has increased the installation speed of the groove copper system while made it easier to install compared to conventional methods. With grooved copper, temperature and weather conditions are no longer a factor when planning installations. There is no Figure 6060 – Tee........................... 4 Figure 6074 – Cap.......................... 4 Figure 6072 – G x G Reducer............ 5 sweating or brazing as this system requires only a wrench for assembly on Figure 6075 – G x Cup Reducer......... 5 grooved end pipe. Figure 6061 – G x G Reducing Tee..... 6 The copper system is “flame-free”. Essentially you save time and enjoy a very reliable system that is both versatile and economical. Safety is a factor as there is no fire hazard, especially in a retrofit installation. The ease of assembly is a great benefit in new construction and ease of disassembly is ideal for renovation, retrofit or expansion. Figure 6064 – G x Cup Reducing Tee.. 6 CTS Copper Adapter, Coupling & Valve Figure 6084 – Flange Adapter........... 7 Figure 6402 CTS SlideLOK Coupling... 8 Figure 6400 Rigid Coupling............... 9 Series 6700 Butterfly Valve........ 10 - 11 Benefits • Fast and easy to assemble. • Easily roll grooved • No flame, no sweat • Proven joint reliability Figure 6402 CTS SlideLOK Coupling.. 12 - 13 • Each joint has a union. • Accepted and approved. Figure 6400 Rigid Coupling..............14 • Provides rigidity • Economical and reliable Installation Instructions Technical Information CTS Copper Roll Groove Specifications.. 15 CTS - 3.14 GRUVLOK C ANVIL PRODUCT LINE Gruvlok® CTS Copper System CTS Copper Fittings CTS Copper Fittings are produced with groove and cup ends in a variety of fitting configurations. The fittings are constructed to ASTM B75 UNS C12200 with minimum copper content of 99.9%. Fitting pressure ratings match the ratings of the Figure 6400 Coupling. C to E C to E C to E E to E Fig. 6050 Fig. 6051 Fig. 6060 Fig. 6074 Dimensions/Weights — Elbows, Tees & Caps Fig. 6051 45˚ Elbow Fig. 6060 Tee Fig. 6074 Cap Copper Tube Diameter C to E Wt. Ea. C to E Wt. Ea. C to E Wt. Ea. E to E Wt. Ea. In. In./mm In./mm Lbs./kg In./mm Lbs./kg In./mm Lbs./kg In./mm Lbs./kg 2.125 2.91 0.75 2.19 0.61 2.69 1.45 2.00 0.36 54.0 74 0.34 56 0.28 68 0.66 51 0.16 2.625 3.31 1.15 2.31 0.89 3.20 2.37 2.00 0.50 66.7 84 0.52 59 0.40 81 1.07 51 0.23 3.125 3.81 1.88 2.59 1.38 3.52 3.38 2.00 0.69 79.4 97 0.85 66 0.63 89 1.53 51 0.31 4.125 4.75 4.07 3.19 2.99 4.25 5.77 2.00 1.15 104.8 121 1.85 81 1.36 108 2.62 51 0.52 5.125 5.94 6.94 3.25 4.00 5.94 12.84 2.75 1.81 130.2 151 3.15 83 1.81 151 5.82 70 0.82 6.125 6.94 11.12 3.63 6.16 6.94 21.00 3.13 2.68 155.6 176 5.04 92 2.79 176 9.52 80 1.22 8.125 7.75 21.81 4.25 13.66 7.75 21.81 – – 206.4 197 9.89 108 6.20 197 9.89 – – 2 21/2 3 4 5 6 8 4 Fig. 6050 90˚ Elbow Nominal Size | anvil INTERNATIONAL CTS - 3.10 TS COPPER ANVIL PRODUCT LINE Gruvlok CTS Copper System ® Concentric Reducers Dimensions/Weights --- Reducers E to E Nominal Size In. 2x1 Fig. 6072 2 x 1 /4 1 2 x 11/2 2 /2 x 1 1 2 /2 x 1 /4 1 1 21/2 x 11/2 E to E Cup 2 /2 x 2 1 3 x 11/2 3x2 3 x 2 /2 1 Fig. 6075 4x2 4 x 2 /2 1 4x3 5x3 5x4 6x3 6x4 6x5 8x6 CTS - 3.10 Fig. 6072 Groove x Groove Fig. 6075 Groove x Cup E to E Wt. Ea E to E Cup Length Wt Ea. In./mm Lbs./kg In./mm In./mm Lbs./kg – – 2.70 0.91 0.32 – – 68.6 23.1 0.15 – – 3.00 0.97 0.36 – – 76.2 24.6 0.16 – – 2.94 1.09 0.38 – – 74.7 27.7 0.17 – – 3.25 0.91 0.53 – – 82.6 23.1 0.24 – – 3.52 0.97 0.59 – – 89.4 24.6 0.27 – – 3.45 1.09 0.59 – – 87.6 27.7 0.27 3.29 0.58 3.30 1.34 0.58 83.6 0.26 83.8 34.0 0.26 – – 3.68 1.09 0.84 – – 93.5 27.7 0.38 2.50 0.58 4.10 1.34 0.97 63.5 0.26 104.1 34.0 0.44 2.50 0.62 – – – 63.5 0.28 – – – 4.75 1.71 4.75 1.34 1.76 120.7 0.78 120.7 34.0 0.80 3.00 1.12 – – – 76.2 0.51 – – – 3.00 1.22 – – – 76.2 0.55 – – – 3.88 2.11 – – – 98.6 0.96 – – – 3.38 1.97 – – – 85.9 0.89 – – – 4.38 2.96 – – – 111.3 1.34 – – – 3.88 2.87 – – – 98.6 1.30 – – – 3.38 2.78 – – – 85.9 1.26 – – – 5.00 6.60 – – – 127.0 2.99 – – – www. a nv i lin t l .com | 5 GRUVLOK C ANVIL PRODUCT LINE Gruvlok® CTS Copper System Reducing Tees Dimensions/Weights --- Reducing Tees Fig. 6064 Fig. 6061 Nominal Size Groove x Groove x Groove In. 2 x 2 x /4 3 2x2x1 2 x 2 x 11/4 2 x 2 x 11/2 2 /2 x 2 /2 x /4 1 1 3 2 /2 x 2 /2 x 1 1 1 2 /2 x 2 /2 x 1 /4 1 1 1 2 /2 x 2 /2 x 1 /2 1 1 1 2 /2 x 2 /2 x 2 1 C to E 1 3 x 3 x /4 3 3x3x1 3 x 3 x 11/4 3 x 3 x 1 /2 1 C to ØE 3x3x2 3 x 3 x 2 /2 1 Fig. 6061 4 x 4 x /4 3 4x4x1 4 x 4 x 11/4 C to E 4 x 4 x 11/2 4x4x2 4 x 4 x 2 /2 1 C to ØE Cup Length 4x4x3 5x5x3 Fig. 6064 5x5x4 6 x 6 x 2 /2 1 6x6x3 6x6x4 6x6x5 6 | anvil INTERNATIONAL Groove x Groove x Cup C to E C to ØE Wt. Ea C to E C to ØE Cup Length Wt Ea. In./mm In./mm Lbs./kg In./mm In./mm In./mm Lbs./kg – – – 2.20 1.98 0.75 0.88 – – – 56 50 19 0.40 – – – 2.33 2.20 0.91 1.03 – – – 59 56 23 0.47 – – – 2.48 2.35 0.97 1.12 – – – 63 60 25 0.51 – – – 2.55 2.28 1.09 1.25 – – – 65 58 28 0.57 – – – 2.27 2.18 0.75 1.25 – – – 58 55 19 0.57 – – – 2.40 2.40 0.91 1.38 – – – 61 61 23 0.63 – – – 2.52 2.57 0.97 1.56 – – – 64 65 25 0.71 – – – 2.70 2.68 1.09 1.88 – – – 69 68 28 0.85 3.28 3.38 2.54 – – – – 83 86 1.15 – – – – – – – 2.45 2.60 0.75 1.88 – – – 62 66 19 0.85 – – – 2.54 2.79 0.91 2.04 – – – 65 71 23 0.93 – – – 2.63 2.89 0.97 2.13 – – – 67 73 25 0.97 – – – 2.85 3.00 1.09 2.25 – – – 72 76 28 1.02 3.00 3.38 2.90 – – – – 76 86 1.32 – – – – 3.25 3.50 3.16 – – – – 83 89 1.43 – – – – – – – 2.95 3.00 0.75 3.63 – – – 75 76 19 1.65 – – – 3.10 3.22 0.91 3.94 – – – 79 82 23 1.79 – – – 3.25 3.47 0.97 4.24 – – – 83 88 25 1.92 – – – 3.35 3.65 1.09 4.47 – – – 85 93 28 2.03 3.66 4.13 5.14 – – – – 93 105 2.33 – – – – 3.94 4.06 5.36 – – – – 100 103 2.43 – – – – 4.19 4.16 5.88 – – – – 106 106 2.67 – – – – 3.75 4.63 7.45 – – – – 95 118 3.38 – – – – 4.25 4.56 8.13 – – – – 108 116 3.69 – – – – 3.63 5.13 9.42 – – – – 92 130 4.27 – – – – 3.69 5.19 10.06 – – – – 94 132 4.56 – – – – 4.19 5.13 10.86 – – – – 106 130 4.93 – – – – 4.69 5.19 12.73 – – – – 119 132 5.77 – – – – CTS - 3.10 TS COPPER ANVIL PRODUCT LINE Gruvlok CTS Copper System ® Figure 6084 Flange Adapter The Gruvlok® Fig. 6084 Flange Adapter allows for direct connection of Class 125 or Class 150 flanged components to the CTS Copper System. The CTS Copper Flange Adapter (Sizes 2" thru 6") conform to ANSI class 125/150 bolt patterns and is rated at 300 PSIG (20.7 bar). The flange is powder coated with Nylon-11. E to E Figure 6084 Flange Adapter Nominal Size Copper Tube Diameter E to E Approx. Wt. Ea. In. In./mm In./mm Lbs./kg 2.125 3.0 0.85 54.0 76.2 0.39 2.625 3.5 1.34 66.7 88.9 0.61 3.125 3.5 1.73 79.4 88.9 0.78 4.125 3.5 2.43 104.8 88.9 1.10 5.125 3.5 3.27 130.2 88.9 1.48 6.125 4.0 4.78 155.6 101.6 2.17 2 2½ 3 4 5 6 CTS - 3.10 www. a nv i lin t l .com | 7 GRUVLOK C ANVIL PRODUCT LINE Gruvlok® CTS Copper System Figure 6402 CTS SlideLOK® Ready for Installation Coupling The CTS SlideLOK coupling is a ready for installation coupling designed to reduce installation time. The slide action allows for greater flexibility during installation. The patented gasket provides four separate sealing surfaces for added protection. The engineered metal-to-metal installation requirement is a quick and easy indication of proper assembly. The CTS SlideLOK is designed to be used with copper tube sizes 2" - 4" and produces a secure, rigid joint connection. The CTS SlideLOK coupling allows for a maximum working pressure of 300 psi for type K, L or M. Contact an Anvil representative for other copper tube pressure ratings. SlideLOK Pressure Responsive Gasket Patent D680629, D680630, D696751 Material Specifications Housing: Ductile iron conforming to ASTM A-536, Grade 65-54-12 Gaskets: Grade “EP” EPDM (Copper Color Code) Service Temperature Range: -40°F to +250°F(-40°C to +121°C) Recommended for water service, diluted acids, alkaline solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Coating: Rust inhibiting paint — Color: Copper (standard) ANSI Bolts and Heavy Hex Nuts: Heat treated oval neck bolts conforming to ASTM A 183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A 563 Grade A or Grade B, or J995 Grade 2. Bolts and nuts are provided zinc electroplated per ASTM B633 Class Fe/Zn 5. NSF 61 Certified for cold +86˚F (+30˚C) and hot +180˚F (+82˚C) potable water service. Lubrication: Standard Gruvlok Xtreme Gasket Type: SlideLOK (2" - 4") Z Y Z Y Xa Xb Figure 6402 CTS SlideLOK Coupling Nominal Size Range of Pipe End Separation Xa Xb Y Z Lbs./kN In./mm In./mm In./mm In./mm In./mm 1,064 0-0.08 31⁄2 31⁄8 79 51⁄2 140 115⁄16 2 66.7 300 20.7 1,624 0-0.08 0-2.0 43⁄8 111 4 102 6 152 115⁄16 2 3.125 79.4 300 20.7 2,301 0-0.08 0-2.0 47⁄8 124 49⁄16 116 63⁄4 171 115⁄16 2 4.125 300 4,009 0-0.08 61⁄4 53⁄4 8 2 2 O.D. Max. Working Pressure Max. End Load In./DN(mm) In./mm PSI/bar 2 2.125 54.0 300 20.7 21⁄2 2.625 3 4 50 65 80 100 8 | 104.8 20.7 anvil INTERNATIONAL 4.73 7.22 10.24 17.83 0-2.0 0-2.0 Coupling Dimensions 89 159 146 203 Coupling Bolts 49 49 49 51 Qty. Size In./mm ⁄2 x 23⁄4 Specified Torque § Min. Max. Ft.-Lbs/N-M Approx. Wt. Ea. Lbs./kg M12 X 70 80 110 100 2.5 ⁄2 x 23⁄4 M12 X 70 80 110 100 2.8 ⁄2 x 31⁄2 M12 X 85 80 110 100 3.2 ⁄2 x 31⁄2 80 100 4.5 1 1 1 1 M12 X 85 110 150 150 150 150 1.1 1.3 1.5 2.0 CTS - 3.14 TS COPPER ANVIL PRODUCT LINE Gruvlok CTS Copper System ® Figure 6400 Rigid Coupling The Figure 6400 Rigid Coupling is specially designed to provide a rigid pipe connection to meet the specific demands of copper tubing installation size 2"-8". Fast and easy swingover installation of the rugged lightweight housing produces a secure rigid pipe joint. Available with Grade “E” Copper EPDM flush gap style gasket. Gasket has service temperature range of -40˚F to +230˚F. NSF 61 Certified for cold +86˚F (+30˚C) and hot +180˚F (+82˚C) potable water service. Material Specifications Housing: Ductile iron conforming to ASTM A-536, Grade 65-54-12 Coatings: Rust inhibiting enamel paint — Color: Copper For other coating requirements contact your Anvil Representative. ANSI Bolts and Heavy Hex Nuts: Heat treated carbon steel oval neck bolts conforming to the physical properties of ASTM A 183 with a minimum tensile strength of 110,000 PSI. Bolts and nuts are provided zinc electroplated as standard. Gaskets: Grade “EP” EPDM Flush Gap Gasket (Copper Color Code) Service Temperature Range: -40°F to +250°F(-40°C to +121°C) Recommended for water service, diluted acids, alkaline solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. NSF 61 Certified for cold +86˚F (+30˚C) and hot +180˚F (+82˚C) potable water service. Z Y Figure 6400 Rigid Coupling Nominal Size In. 2 21⁄2 3 4 5 6 8 Copper Max Wk. Tube Pressure Diameter Max End Load Range of Pipe End Separation Coupling Dimensions In./mm X Y Z In./mm PSI/bar Lbs./kN In./mm 2.125 300 1063 0 - 0.08 3.00 5.00 1.68 54.0 20.7 4.73 0 - 2.0 76 127 43 2.625 300 1623 0 - 0.08 3.50 5.50 1.68 66.7 20.7 7.22 0 - 2.0 89 140 43 3.125 300 2300 0 - 0.08 4.18 6.28 1.68 79.4 20.7 10.23 0 - 2.0 106 159 43 4.125 300 4007 0 - 0.13 5.20 7.50 1.70 104.8 20.7 17.82 0 - 2.4 132 191 43 5.125 300 6186 0 - 0.13 6.20 9.10 1.80 130.2 20.7 27.51 0 - 2.4 157 231 46 6.125 300 8835 0 - 0.13 39.30 0 - 2.4 155.6 20.7 8.125 300 206.4 20.7 15547 0 - 0.13 69.15 0 - 2.4 7.20 10.20 1.80 183 259 315 Qty. Size 51 Approx. Wt. Ea. In./mm Lbs./Kg ⁄8 x 21⁄4 1.53 ⁄8 x 21⁄4 1.78 ⁄2 x 3 2.76 2 3 2 3 X 0.69 0.81 2 1 2 1 1.25 ⁄2 x 3 3.27 1.48 2 5 ⁄8 x 31⁄4 4.71 2 5 ⁄8 x 31⁄4 5.24 2 5 ⁄8 x 31⁄4 7.67 Y Z 2.14 46 9.32 12.40 2.00 237 Coupling Bolts 2.38 3.48 X Pressure ratings and end loads are based on use with ASTM B88 Type K or L tubing. For pressure ratings on Type M and DWV, contact your Anvil Representative. CTS - 7.11 www. a nv i lin t l .com | 9 GRUVLOK C ANVIL PRODUCT LINE Gruvlok® CTS Copper System Series 6700 CTS Copper Butterfly Valve The lever handle bronze body butterfly valve is designed for use with grooved copper tubing (CTS), fittings and couplings. This valve features a 10 position lever handle, bronze body and EPDM rubber encapsulated dual-seal disc. Both bronze valve body and the EPDM rubber disc obtained certification to ANSI/NSF 61 for use in potable water systems, and is rated to 300 PSI (20 bar). Material Specifications Valve Body: ASTM B584 C89836; Bronze, Low Lead NSF/ANSI 61 Disc: ASTM A536 Gr. 65-45-12; Ductile Iron Disc Encapsualtion: Grade “EP” EPDM: Service temperature range: -40˚F to +250˚F (-40˚C to +121˚C). Recommended for water service, diluted acids, alkaline solutions, and oil-free air. Not recommended for use in petroleum applications. Hot Water / Annex G Upper & Lower Shafts: Stainless Steel Type 17-4PH; ASTM A564 Certifications: ANSI/NSF61 for use in Cold +86F(+30C) and Hot +180F(+82C) potable water systems. Annex G. UPC. J F H D E øC B A G Series 6700 CTS Copper Butterfly Valve Nominal Size In. 21⁄2 3 4 5 6 10 | Copper Tube Diameter A B C D E Dimensions F G H J Weight In./mm In./mm In./mm In./mm In./mm In./mm In./mm In./mm In./mm In./mm 2.625 3.77 2.22 2.63 3.83 7.20 10.50 12.39 2.00 4.43 Lbs./kg 4 66.7 95.8 56.4 66.7 97.3 182.5 266.7 314.6 50.8 112.5 1.8 3.125 3.77 2.60 3.13 4.08 7.84 10.50 12.39 2.00 4.43 5 79.4 95.8 65.9 79.4 130.5 198.2 266.7 314.6 50.8 112.5 2.3 4.125 4.63 3.10 4.13 4.72 8.97 10.50 12.81 2.00 4.43 8 104.8 117.6 78.7 104.9 119.9 227.8 266.7 325.5 50.8 112.5 3.8 5.125 5.88 3.85 5.13 5.22 10.27 10.50 13.44 2.00 4.43 14 130.2 149.4 97.8 130.2 132.6 260.9 266.7 341.4 50.8 112.5 6.4 6.125 5.88 4.36 6.13 5.75 11.31 10.50 13.44 2.00 4.43 18 155.6 149.4 110.8 155.6 146.2 287.3 266.7 341.4 50.8 112.5 8.1 anvil INTERNATIONAL CTS - 7.11 TS COPPER ANVIL PRODUCT LINE Gruvlok CTS Copper System ® Flow Data 20000 6" Values for flow of water at +60˚F (+16˚C) Q Cv = DP 10000 9000 8000 7000 5" 6000 5000 4000 Where: Cv = Flow coefficient Q = Flow (GPM) DP = Pressure drop (psi) 4" 3000 3" 21/2" 1000 900 800 700 600 Valve Size Flow (Water) - gpm 2000 500 400 300 200 100 90 80 70 60 50 40 30 20 10 .1 .2 .3 .4 .5 .6 .7.8.9 1 2 3 4 5 6 7 89 10 20 Pressure Drop - psig Gruvlok CTS Copper Butterfly Valve Series 6700 (Ordering Information) Sample Part Number 4" 6711-1 ––> 4" 67 1 1- 1 Size Series Disc Coating Operator Shaft 2 /2" - 6" 6700 1 1 - EPDM (Grade EP) 0 - None 1 - 17-4 PH S/S 1 - 10 Pos. Handlever CTS - 7.11 www. a nv i lin t l .com | 11 GRUVLOK C ANVIL PRODUCT LINE Gruvlok® CTS Copper System Figure 6402 CTS SlideLOK™ Rigid Coupling INSTALLATION READY FOR INSTALLATION - RIGHT OUT OF THE BOX Do not disassemble the CTS SlideLOK™ Coupling. The Figure 6402 coupling is ready for installation. The bolt and gasket do not need to be removed. Step 3 – Assembly. The CTS SlideLOK Figure 6402 may be installed by one of two methods. The preferred method depends on the type of components being joined and their orientation. Please review both methods before installing. Step 2 – Gasket Preparation. Step 1 – Copper Tube Preparation. Copper tube ends are to be roll grooved copper tube according to Anvil specifications. The tube end must be smooth and free from metal burrs or projections. Ensure the gasket is suitable for the intended application by referring to the Anvil gasket compatibility chart. Apply a light coating of Gruvlok® Xtreme™ Lubricant to exposed gasket surfaces. Method #1 Method #2 Slide the CTS SlideLOK coupling completely over the grooved copper tube end. This will allow a clear and un-obstructed view of the tube for correct alignment. Slide the CTS SlideLOK™ coupling half way onto the copper tube end or fitting. This will better accommodate fitting, and valve accessories during installation. A. Slide the coupling on the copper tube past the groove. The bolts and nuts can be hand tightened to position the coupling in place. C. Slide the coupling back B. Align the mating copper D. Follow the instructions on tube end. Align the two adjoining tubes together. fastening the coupling as shown in Step 4. over the grooves so that the coupling keys are located over the respective grooves on both copper tube ends. or fitting towards the coupling and insert so that the groove and coupling keys are aligned. Step 5 – Final Inspection. The CTS SlideLOK coupling is designed to achieve pad to pad (metal-to-metal contact) using either an impact wrench* or wrench. The intended torque range for the coupling is located in Table 1. Securely tighten nuts alternately and equally until the housing halves are in metal-to-metal contact. Ensure the coupling is properly aligned in the grooves and the housing halves are in metal-tometal contact, depicted in the pictures to the right. 12 | anvil INTERNATIONAL correctly position the couplings keys over the respective grooved ends. B. Bring the copper tube end Step 4 – Final Assembly. *CAUTION: When using an impact wrench, verify that the output of the impact wrench is within the required torque range. It is recommended that a torque wrench be used for accurate assembly in order to obtain specified performance. C. Hand tighten the nuts to A. Slide the coupling on the fitting so that the groove and keys are aligned. D. Follow the instructions on fastening the coupling as shown in Step 4. Table 1 – Torque Ranges Sizes Torque In. 2-4 Ft.-Lbs 80 - 100 CTS - 3.14 TS COPPER ANVIL PRODUCT LINE Gruvlok CTS Copper System ® Figure 6402 CTS SlideLOK™ Rigid Coupling re-INSTALLATION Reinstallation of the Figure 6402 CTS SlideLOK™ Coupling The CTS SlideLOK coupling is designed to be installed in the ready for installation assembly position once. After the initial assemble the following steps are to be taken to re-install the Fig. 6402 CTS SlideLOK coupling. Step 1 – De-pressurize the System. De-pressurize the system before removing the CTS SlideLOK Coupling. Disassemble the couplings by removing the nuts, bolts and gasket from the housing halves. A wrench is required to overcome the epoxy used to secure the nuts on the bolts. Step 2 – Copper Tube Preparation. Copper tube ends are to be roll grooved copper tube according to Anvil specifications. The tube end must be smooth and free from metal burrs or projections. Step 3 – Gasket Preparation. Ensure the gasket is suitable for the intended application by referring to the Anvil gasket compatibility chart. A light coating of Gruvlok® XTreme™ lubricant must be applied to the gasket prior to installation. Step 4 – Copper Tube Alignment and Gasket Installation. Place each housing halves on the copper tube making sure the housing key fits into the groove. Be sure that the tongue and recess portions of the housing mate properly. Insert the bolts. Slide the gasket onto the copper tube then align the two tube ends together. Pull the gasket into position, centering it between the grooves on each copper tube. Gasket should not extend into the groove on either copper tube. Step 6 – Final Assembly. Step 7 – Final Inspection. The CTS SlideLOK coupling is designed to achieve pad to pad (metal-to-metal contact) using either an impact wrench* or wrench. The intended torque range for the coupling is located in Table 1. Securely tighten nuts alternately and equally until the housing halves are in metal-to-metal contact. Ensure the coupling is properly aligned in the grooves and the housing halves are in metal-tometal contact, depicted in the pictures to the right. *CAUTION: When using an impact wrench, verify that the output of the impact wrench is within the required torque range. It is recommended that a torque wrench be used for accurate assembly in order to obtain specified performance. Step 5 – Housing Assembly. Table 1 – Torque Ranges Sizes Torque In. 2-4 Ft.-Lbs 80 - 100 Incorrect Installation Examples Low Torque or Out of Groove CTS - 3.14 Excess Torque or Shallow Groove Dimension www. a nv i lin t l .com | 13 GRUVLOK C ANVIL PRODUCT LINE Gruvlok® CTS Copper System The 6400 Rigid Coupling is a snap. STEP 1 – Check and lubricate gasket STEP 2 – Gasket Installation STEP 4 – Assemble Housings Installation & Assembly The Fig. 6400 Coupling from Gruvlok is specially designed to provide a rigid pipe connection to meet the specific demands of copper tubing installation. Fast and easy swing-over installation of the rugged lightweight housing produces a secure, rigid pipe joint. Available with the EPDM flush gap style gasket as the standard gasket. Step1 – Lube Gasket. Check the gasket to be sure it is compatible for the intended service. Apply a thin coating of Gruvlok® Xtreme Lubricant to the entire surface, both internal and external, of the gasket. Be careful that foreign particles do not adhere to the lubricated surfaces. STEP 3 – Alignment Step 2 – Install Gasket. Slip the gasket over one tube, making sure the gasket lip does not overhang the tube end. Step 3 – Alignment. After aligning the two tube ends together, pull the gasket into position, centering it between the grooves on each tube. The gasket should not extend into the groove on either tube or between the tube ends. Step 4 – Assemble Housings. Remove one nut and bolt and loosen the other nut. Place one housing over the gasket, making sure the housing keys fit into the tube grooves. Swing the other housing over the gasket and into the grooves on both tubes, making sure the tongue and recess of each housing is properly mated. Re-insert the bolt and run-up both nuts finger tight. Step 5 – Tighten Nuts. Securely tighten nuts alternately and equally to the specified bolt torque, keeping the gaps at the bolt pads evenly spaced. Assembly is complete. Visually inspect the pipe joint to assure the coupling keys are fully engaged in the pipe grooves. The bolt pads are to have equal gaps on each side of the coupling. NOTE: Copper is a soft material, and in some cases, the bolt pads may come close to metal-to-metal contact. 14 | anvil INTERNATIONAL CAUTION: Uneven tightening may cause the gasket to pinch. The gasket should not be visible between segments after the bolts are tightened. Proper torquing of coupling bolts is required to obtain specified performance. Over torquing the bolts may result in damage to the bolt and/or casting which could result in pipe joint separation. Under torquing the bolts may result in lower pressure retention capabilities, lower bend load capabilities, joint leakage and pipe joint separation. STEP 5 – Tighten Nuts Specified Bolt Torque Bolt Size Wrench Size Specified Bolt Torque* In. In. Ft.-Lbs ⁄8 1 ⁄2 5 ⁄8 ⁄16 7 ⁄8 11⁄16 30-45 30-45 60-90 3 11 * Non-lubricated bolt torques. CTS - 3.10 TS COPPER ANVIL PRODUCT LINE Gruvlok CTS Copper System ® Roll Groove Specifcations B T OD Flare A C D Gruvlok CTS Copper System – Roll Groove Specifications -1- -2-3-4-5-6-7-8Nominal Min. Max. Tubing Outside Diameter Gasket Seat “A” Groove Width “B” Groove Diameter “C” Nominal +/– 0.03 in. +0.03/–0.00 in. Groove Depth Wall Flare Size Tolerance Actual Actual Tolerance +/– 0.76mm +0.76/–0.00mm “D” “T” Diam. +0.000 In. 2 2 /2 1 3 4 5 6 8 In./mm 2.125 + In./mm – In./mm 0.002 0.002 In./mm In./mm In./mm – In./mm In./mm In./mm In./mm 0.610 0.300 2.029 -0.020 0.048 0.058 2.220 54.0 0.05 0.05 15.5 7.6 51.54 -0.51 1.2 1.6 56.4 2.625 0.002 0.002 0.610 0.300 2.525 -0.020 0.050 0.065 2.720 1.7 66.7 0.05 0.05 15.5 7.6 64.14 -0.51 1.3 3.125 0.002 0.002 0.610 0.300 3.025 -0.020 0.050 79.4 0.05 0.05 15.5 7.6 76.84 -0.51 1.3 4.125 0.002 0.002 0.610 0.300 4.019 -0.020 0.053 104.8 0.05 0.05 15.5 7.6 102.08 -0.51 1.3 5.125 0.002 0.002 0.610 0.300 4.999 -0.020 0.053 130.2 0.05 0.05 15.5 7.6 126.97 -0.51 1.3 6.125 0.002 0.002 0.610 0.300 5.999 -0.020 0.063 155.6 0.05 0.05 15.5 7.6 152.37 -0.51 1.6 8.125 0.002 0.004 0.610 0.300 7.959 -0.020 0.083 206.4 0.05 0.10 15.5 7.6 202.16 -0.51 2.1 DWV DWV DWV DWV DWV 69.1 3.220 81.8 4.220 107.2 5.220 132.6 6.220 158.0 8.220 208.8 Column 1: Nominal tubing size ASTM B88 Column 2: Outsize diameter of copper tubing per ASTM B88. Allowable tolerance from square cut ends is 0.030”/0.76mm for sizes 2”-3”; 0.045”/1.14mm for sizes 4-8” Column 3: Gasket seat must be free from scores, roll marks, indentations, grease and dirt which may interfere with gasket sealing. Column 4: Groove width is to be free from chips, dirt, etc. which may interfere with proper coupling assembly. Column 5: Groove diameter must be of uniform depth for the entire circumference of the tubing. See column 6. Column 6: Groove depth is for reference only; the groove diameter must conform to column 5. Column 7: DWV (Drain, Waste and Vent Piping) per ASTM B306. Column 8: Maximum flare diameter is the OD at the most extreme tubing diameter. CTS - 3.10 www. a nv i lin t l .com | 15 Corporate Offices 2 Holland Way, Exeter, NH 03833 Tel: 603-418-2800 Fax: 603-418-2833 E-mail: [email protected] U.S. Regional Service Centers Northern Region Regional Distribution & Customer Service Center 7979 W. 183rd Street, Unit D, Tinley Park, IL 60477 Tel: 708-885-3000 Fax: 708-534-5441 Toll Free: 1-800-301-2701 Southern Region Regional Distribution & Customer Service Center 1401 Valley View Lane, Suite 150, Irving, TX 75061 Tel: 972-871-1206 Fax: 972-641-8946 Toll Free: 1-800-451-4414 Canada SErvice CEnter Anvil International Canada Customer Service Center 390 Second Avenue, P.O. Box 40, Simcoe, Ontario N3Y 4K9 Tel: 519-426-4551 Fax: 519-426-5509 international sales Europe and Middle East Region Rick van Meesen [email protected] Tel: +31-53-5725570 Fax: +31-53-5725579 Mexico, Puerto Rico and Latin America Region International Customer Service Tel: +1-708-885-3000 Fax: +1-708-534-5441 B U I L D I N G C O N N E C T I O N S T H A T L A S T #075/Printed in USA/© Copyright 2014 Revision Date: 3.18.14
© Copyright 2024