CIPET EXTENSION CENTRE - GUWAHATI CONSTRUCTION OF BUILDING FOR VTC UNDER THE SCHEME "ENRICHING TECHNICAL INFRASTRUCTURE FACILITIES & CAPABILITIES TO MEET INDUSTRY NEEDS" UNDER XII FIVE YEAR PLAN. INTERNAL ELECRTRICAL WORKS Sl. No. Description Unit (in Figures) Copper wiring in PVC Conduit : 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, Point suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group - C 2. Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. Metre mm FR PVC insulated copper conductor single core cable for loop earthing as required. 3. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre b) 2 X 10 sq. mm + 1 X 10 sq. mm earth wire Qty Metre 41 15.00 160.00 25.00 Rate in (Rs.) (in Words) Amount Sl. No. Description Unit Qty 4. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm Metre 20.00 b) 25 mm Metre 30.00 a) 100 mm x 100 mm x 60 mm deep Each 5 b) 180 mm x 100 mm x 60 mm deep Each 7 6. Installation, testing and commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq. mm FRLS PVC insulated, copper Each conductor, single core cable, earthing the regulator etc. as required. 11 7. Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 Each amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). 5 5. Supplying and fixing metal box of following sizes (normal) on surface or recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit 8. Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover Each for the socket out let and complete with connections, testing and commissioning etc. as required. 9. Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to Each terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) Qty 1 1 2 + 12 way, Double door 10. Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, with provision of 100 amps TP 16 KA MCCB as incomer, Each interconnection between incomer MCCB and bus bars (but without MCB's/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 Way TP 5 Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit Qty 11. Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Each a) Single pole 10 Each 20 b) Triple pole 12. Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 Each milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 1 40 amps 13. Supplying and Fixing Singe Pole Blanking Plate in the existing Each MCB DB complete etc. as required. 14. Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on Each ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 15. Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic Each laminated sheet cover on the fan box etc. as required. 20 25 11 Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit 16. Installation of exhaust fan / wall fan in the existing opening, including making good the damage, connection, testing, Each commissioning etc. as required. Qty 5 Upto 450 mm sweep EARTHING 17. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering SET pipe etc. with charcoal/ coke and salt as required. 18. Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and SET watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 19. Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. Meter as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 20. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer Meter etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 2 2 30.00 30.00 Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit Qty 21. Providing and fixing 25 mm X 5 mm G.I. strip on surface or Meter in recess for connections etc. as required. 70.00 22. Providing and fixing 25 mm X 5 mm copper strip on surface Meter or in recess for connections etc. as required. 20.00 23. Providing and fixing 4mm dia.copper wire on surface or in Meter recess for loop earthing as required. 35.00 24. Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long Each and fixing the same in ground as required. 25. Provideing and fixing M.V.danger notice plate of 200 mm x 150 mm,made of mild steel at least 2 mm thick and vitreous enamelled white on both side and with inscription in single Each red colour on front side as required. 6 6 Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit 26. MAIN LT FEEDER PANEL- TOOL ROOM EXTENSION BUILDING Supplying and installation of metal enclosed free standing floor readable mounted front operated cubical type switch gear panel suitable for OUTDOOR Type installation conforming to IS: 8623 (Part I & II). Panel should be made of sheet steel and thickness not less than 2mm and structural steel having light section with arrangement for sealingthe covers and lockable doors. The panel shall be completely Set dust tight and vermin proof and shall be painted with anti corrosive and anti condensation type two coats of primer and two coats of paint conforming to Degree of Protection for enclosure shall be IP-55. All wiring shall be PVC insulated and PVC sheathed of 1100 volt grade of required size. The panel should have provision of entry of cable at the bottom and also provision of out going feeders from the bottom of the panel. The panel shall be incorporated with single copper busbar system. The bus bar shall be of high quality copper of uniform cross section. The panel shall consist of the following items (viz. Voltmeter, Ammeter, CT, indicating lamps, selector switch etc.) connected as per drawing and shall be flush mounted on the front of the panel. Qty 1 Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit Qty Incommer: 250 A ,4P, MCCB, 36 KA - 1 No. Digital Ammeter - 1 No. Digital Voltmeter - 1 No. Electronic CT Operated Energy Meter [KWH] CT 250/5 -2 Sets. Switch Fuse Unit - 6 Nos Selector Switch - 2 Nos Indicating Lamp 1 Set Bus-Bars: 512 A TPN electrolytic Copper Bus Bar of uniform cross-section (32MM X10mm ) – 1 set Outgoing: 63 A 4P MCCB 25 KA – 5 Nos. 32 A 4P MCB – 2 Nos. 40A DP MCB - 3 Nos LIGHTING FITTING & FIXURES 27. Supplying of pre-wired fluorescent lighting fixure (BAJAJ / CROMPTON/PHILIPS make) complete with Fourescent Tubes/CFL lamps etc. as required complete Strip light fixture with VPIT open contruction copper ballast and ABS end plates Suitable for T8 FTL of make Havells Cat Each No. LHDF02104009 or equivalent with 1 no. 40W Fluorescent Tube Light [TL]. 10 Industrial luminaires with copper ballast, reflector & 2x36 watt. flourescent tube. (WIPRO make) Model-WCF 26236 Each SGW 2X36W FTL. [DTL(I)] 15 Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description Unit 28. Supplying of 1200 mm sweep ceiling fan of make HAVELLS Cat/Brand PACER of colour White, Brown or Bianco Each complete with down rod or equivalent etc. [F] 29. Supplying of 450 mm sweep 900RPM Single phase Heavy duty exhaust fan of make Bajaj Cat/Brand Supreme Each complete with all accessories complete or equivalent. Qty 11 5 CABLE 30. Supply and laying of following size of PVC/XLPE insulated and PVC sheathed 11 KV grade aluminium conductor LT armoured UG cable laid in ground/partially in air (10% of cable length) including excavation of cable trench upto depth of 75cm. Refilling, protective brick covering, sand cushioning etc. complete handling of surplus soil, debries etc. to proper place as speciefied and directed by the deptt. a) 25.00 mm² 3½ core U.G. Cable Mtr. 70.00 b) 300.00 sqmm 31/2 core UG cable Mtr. 45.00 a) 25.00 mm² 3½ core U.G. Cable in 40mm dia medium quality Mtr. G.!. Pipe 20.00 31. Supply and laying of following size of PVC/XLPE insulated and PVC sheathed 11 KV grade aluminium conductor LT armoured UG cable laid in pucca flooring road crossing, drain crossing and partially in air through GI pipe (Tata/Nezone make) with necy. bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the Deptt. Rate in (Rs.) (in Figures) (in Words) Amount Sl. No. Description b) 300.00 sqmm 31/2 core UG cable in 100mm dia medium quality. Unit Mtr. 32. Supplying and making outdoor end termination with resin cast type for PVC insulated and PVC sheathed aluminium Each conductor cable of 1.1 KV grade for the following size as required. size= 3½ & 4x300 MCB/MCCB 33. Supplying and fixing following rating, Double pole, 415 volts, MCB in the existing MCB DB complete with connections, Each testing and commissioning etc. as required. Qty 5.00 1 1 40 amps 34. Supplying and fixing following rating, four pole, 415 volts, 25KA MCCB in the existing MCB DB complete with Each connections, testing and commissioning etc. as required. 63 amps 5 Rate in (Rs.) (in Figures) (in Words) Amount Sl. Description Unit No. 35. Supply, Installation antistatic rubber mat suitable for 1.1 KV Sq.M Voltage grade 36. Supply, Fitting Fixing of Shock Treatment Chart Each Qty Rate in (Rs.) (in Figures) (in Words) 4.00 2 Total Signature of the Contractor: Date & Seal: Amount Rs.
© Copyright 2024