Vascular and cardiothoracic Surgery Solutions Atrium Medical Corporation 5 Wentworth Drive Hudson, NH 03051 Phone: (+1)603-880-1433 Fax: (+1)603-880-6718 www.atriummed.com ATRIUM HAS JOINED MAQUET GETINGE GROUP Effective February 2012 | 3 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | TABLE OF ContentS HEPARIN VASCULAR PRODUCTS GRAFTS INTERGARD KNITTED HEPARIN | 6 INTERGARD KNITTED HEPARIN ULTRATHIN | 7 HEMAGARD KNITTED | 8 HEMAGARD KNITTED ULTRATHIN | 11 KNITTED VASCULAR PRODUCTS GRAFTS PATCHES HEMAGARD PATCH KNITTED | 13 HEMAGARD CAROTID PATCH KNITTED | 14 HEMAGARD CAROTID PATCH KNITTED ULTRATHIN | 15 WOVEN VASCULAR PRODUCTS GRAFTS HEMASHIELD PLATINUM WOVEN DOUBLE VELOUR | 16 HEMASHIELD PLATINUM WOVEN AORTIC BRANCH | 17 CARDIOROOT | 18 PATCHES HEMASHIELD DOUBLE VELOUR FABRIC | 23 OTHER PRODUCTS POLYESTER TAPE | 24 GRAFT SIZERS | 25 | The Gold Standard | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 5 | Over 50 Years OF technical and clinical experience of Vascular Graft Technology MAQUET – THE GOLD STANDARD MAQUET Cardiovascular provides full support to cardiac, Working together with customers, MAQUET combines graft cardiothoracic and vascular surgeons and their teams, manufacturing expertise with trends in cardiovascular surgery performing cardiothoracic and abdominal aneurysm and to develop new and innovative products. The MAQUET peripheral vascular repair. MAQUET maintains a singular Cardiovascular portfolio offers state-of-the art products and focus: to be the first choice in the operating room. service for the optimal treatment of the patients. MAQUET – The Gold Standard. | 6 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | HEPARIN VASCULAR PRODUCTS INTERGARD HEPARIN: A UNIQUE COMBINATION DRUG / DEVICE POLYESTER GRAFT Material: Healing: C ollagen-coated heparin-bonded polyester graft Excellent graft healing and tissue incorporation Available in Knitted and Ultrathin configuration E xternal-velour construction designed to promote optimal Water permeability : ≤ 5ml . cm . min healing -2 -1 INTERGARD Heparin properties: 2 Handling: Proprietary heparin-bonding process designed to allow the Superb handling and host vessel conformability antithrombotic and antiproliferative properties of biologically active heparin to be available locally at the graft surface Hemostasis: No suture hole bleeding Higher patency rates compared to PTFE 1 S ignificantly lower amputation rates than PTFE 1 1. Devine C, McCollum C; North West Femoro-Popliteal Trial Participants. Heparinbonded Dacron or polytetrafluorethylene for femoropopliteal bypass: Five-year results of a prospective randomized multicenter clinical trial. J Vasc Surg. 2004 Nov;40(5):924-31. 2. Becquemin JP, Riff Y, Kovarsky S, et al. Evaluation of a polyester collagen-coated heparin bonded vascular graft. J Cardiovasc Surg 1997 Feb;38(1):7-14. PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Construction Water permeabilit y Wall thickness** Burst strength** 45°suture retention** Knitted Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.49 mm 32.7 kg/cm 2 3.37 kg Ultrathin Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.35 mm 35.3 kg/cm 2 1.83 kg * Testing performed per ANSI/AAMI/ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 7 | HEPARIN VASCULAR PRODUCTS INTERGARD HEPARIN KNITTED STRAIGHT 70 cm length: Diameter 6 mm 7 mm 8 mm 10 mm Reference IGK0006-70H IGK0007-70H IGK0008-70H IGK0010-70H radially supported STRAIGHT Diameter 6 mm 8 mm 6 mm 8 mm Proximal / Distal Length 35/15 cm 35/15 cm 25/15 cm 25/15 cm Supported Length 20 cm 20 cm 30 cm 30 cm BIFURCATED Total Length 70 cm 70 cm 70 cm 70 cm Reference IGK0006RS20H IGK0008RS20H IGK0006RS30H IGK0008RS30H 50 cm length: Diameter 12x6 mm 14x7 mm 16x8 mm 18x9 mm 20x10 mm 22x11 mm Reference *IGK1206H *IGK1407H *IGK1608H *IGK1809H *IGK2010H *IGK2211H * Made on request only INTERGARD HEPARIN KNITTED ultrathin ultrathin straight 40 cm length: Diameter 6 mm 7 mm 8 mm Diameter Reference IGKUT0006-40H IGKUT0007-40H IGKUT0008-40H 70 cm length: Diameter 6 mm 7 mm 8 mm ULTRATHIN radially supported STRAIGHT Reference IGKUT0006-70H IGKUT0007-70H IGKUT0008-70H 6 mm 7 mm 8 mm 6 mm 7 mm 8 mm 6 mm 8 mm Proximal / Distal Length 35/15 cm 35/15 cm 35/15 cm 25/15 cm 25/15 cm 25/15 cm 20/20 cm 20/20 cm Supported Length 20 cm 20 cm 20 cm 30 cm 30 cm 30 cm 45 cm 45 cm Total Length 70 cm 70 cm 70 cm 70 cm 70 cm 70 cm 85 cm 85 cm Reference IGKUT0006RS20H IGKUT0007RS20H IGKUT0008RS20H IGKUT0006RS30H IGKUT0007RS30H IGKUT0008RS30H IGKUT0006RS45H IGKUT0008RS45H | 8 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | KNITTED VASCULAR PRODUCTS HEMAGARD KNITTED Material: Healing: C ollagen-coated polyester graft Excellent graft healing and tissue incorporation Reverse locknit knitting technique K nitted construction designed to promote optimal healing Water permeability : ≤ 5ml . cm -2 . min -1 and significantly reduce the potential for postoperative 1 dilatation HEMAGARD Knitted properties: S uperior proprietary textile design: reverse locknit knitting Handling: technique produces burst strength, radial tensile strength Reverse locknit construction with excellent handling and and suture pull-out strength characteristics which are suturing characteristics significantly greater than corresponding material, which utilize a tricot knit 1 HEMAGARD locknit construction demonstrated long term Hemostasis: No suture hole bleeding stability and resistance to post-operative dilatation PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Construction Water permeabilit y Wall thickness** Burst strength** 45°suture retention** Knitted Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.49 mm 32.7 kg/cm 2 3.37 kg * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. Reverse Locknit Tricot Knit (Collagen impregnated graft) | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 9 | KNITTED VASCULAR PRODUCTS HEMAGARD KNITTED A randomized clinical trial compared the dilatation charac- knit construction. A significantly lower degree of dilatation teristics of the INTERGARD* Knitted collagen coated graft, was found for the reverse locknit construction compared to which incorpates a reverse locknit construction, with both a the warp/tricot knitted grafts. 2 collagen impregnated and uncoated graft with a warp/tricot Mean Aortic Body Dilatation: Femoral Level Mean Dilatation: 6.8% – INTERGARD* REVERSE LOCKNIT POLYESTER 2.5% – INTERGARD* REVERSE LOCKNIT POLYESTER 31.0% – TRICOT KNITTED POLYESTER COLLAGEN IMPREGNATED 23.8% – TRICOT KNITTED POLYESTER COLLAGEN IMPREGNATED 37.8% – TRICOT KNITTED POLYESTER UNCOATED 0 10 20 30 40 50 60 70 80 90 100 31.7% – TRICOT KNITTED POLYESTER UNCOATED 0 10 20 30 % dilatation A clinical study to evaluate the performance of the patency rate for the INTERGARD* knitted graft.3 * F ormally known as the established brand “INTERGARD”, this knitted prosthesis is now rebranded as “HEMAGARD”. 1. Data on file, InterVascular 2. Swartbol P, Albrechtsson U, Parsson H, Norgren L. Dilatation of aortobifemoral grafts after a mean implantation of 5 years. International Angiology 1996 Vol. 15 No. 3 pp. 236-239. 3. INTERGARD Collagen Coated Knitted Vascular Grafts: Results of the U.S. Clinical Trial 60 70 80 90 100 summary of one-year results marketed collagen impregnated control graft was conducted demonstrated fewer complications and a higher primary 50 % dilatation INTERGARD* knitted vascular graft versus a currently at five investigational centers in the United States. The results 40 Acturial Survival Rate Safet y Mortality Explant Amputation Wound/Graft Infection Bleeding Thrombosis/Occlusion Embolism Ef fectiveness Primary Patency INTERGARD* N=311 89.5% (247) Control N=153 80.8% (73) 10.5% 2.3% 0.4% 3.4% 1.4% 8.4% 0.0% 19.2% 4.2% 1.4% 7.1% 3.2% 19.8% 2.1% 91.6% 80.0% | 10 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | KNITTED VASCULAR PRODUCTS HEMAGARD KNITTED Straight 20 cm length: Diameter 6 mm 7 mm 8 mm 10 mm 12 mm 14 mm 18 mm 20 mm 22 mm 24 mm 40 cm length: Reference HGK0006-20 HGK0007-20 HGK0008-20 HGK0010-20 HGK0012-20 HGK0014-20 HGK0018-20 HGK0020-20 HGK0022-20 HGK0024-20 Diameter 6 mm 7 mm 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm Reference HGK0006-40 HGK0007-40 HGK0008-40 HGK0010-40 HGK0012-40 HGK0014-40 HGK0016-40 HGK0018-40 HGK0020-40 HGK0022-40 HGK0024-40 60 cm length: Diameter 12 mm 8 mm 6 mm 8 mm 6 mm 8 mm 8 mm Proximal/ Distal Length 40/15 cm 35/15 cm 35/15 cm 25/15 cm 25/15 cm 20/20 cm Diameter 6 mm 7 mm 8 mm 10 mm 8x8 mm 10x10 mm 8x8 mm 8x8 mm 8x8 mm 10x8x8 mm 8x6x6 mm Distal Length body/branch 20/35 cm 20/25 cm 20/25 cm 25/35 cm 25/35 cm Diameter 6 mm 7 mm 8 mm 10 mm Reference HGK0006-70 HGK0007-70 HGK0008-70 HGK0010-70 Bifurcated Supported Length 15 cm 20 cm 20 cm 30 cm 30 cm 45 cm Total Length 70 cm 70 cm 70 cm 70 cm 70 cm 85 cm Reference HGK0008RS15 HGK0006RS20 HGK0008RS20 HGK0006RS30 HGK0008RS30 HGK0008RS45 AXILLO BIFEMORAL grafts Diameter Reference HGK0012-60 70 cm length: radially supported Diameter 100 cm length: Supported Length body/branch 45/20 cm 45/30 cm 60/30 cm 35/20 cm 35/20 cm Total Length body/branch 100/60 cm 100/60 cm 85/55 cm 85/55 cm 100/55 cm 85/55 cm 85/55 cm Reference HGK A X0808 HGK A X1010 HGK A X0808RS45/20 HGK A X0808RS45/30 HGK A X0808RS60/30 HGKAX100808RS35/20 HGKAX080606RS35/20 50 cm length: Diameter 12 mm x 6 mm 12 mm x 7 mm 14 mm x 7 mm 14 mm x 8 mm 16 mm x 8 mm 16 mm x 9 mm 18 mm x 9 mm 18 mm x 10 mm 20 mm x 10 mm 20 mm x 11 mm 22 mm x 11 mm 24 mm x 12 mm Reference HGK1206 HGK1207 HGK1407 HGK1408 HGK1608 HGK1609 HGK1809 HGK1810 HGK2010 HGK2011 HGK2211 HGK2412 Reference HGK0006-100 HGK0007-100 HGK0008-100 HGK0010-100 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 11 | KNITTED VASCULAR PRODUCTS HEMAGARD KNITTED ultrathin: the ultimate small caliBER graft Material: Healing: C ollagen-coated polyester graft K nitted construction designed to promote optimal healing T hinnest knitted polyester collagen-coated graft on the Provide alternative for peripheral bypass procedures when market vein is not available 1, with comparable patency rates to Reverse locknit knitting technique other prosthetic materials Water permeability : ≤ 5ml . cm -2 . min -1 E xcellent host vessel conformability 2 Wall thickness of 0.35mm Handling: HEMAGARD Knitted Ultrathin properties: Proprietary Ultrathin wall technology designed to over- Reverse locknit construction with excellent handling and suturing characteristics come complications such as hyperplasia, host vessels T hinner and highly compliant graft due to its radial and mismatch, and suture hole bleeding. longitudinal pulsatility Available in radially supported configuration for kink and compression resistance. Hemostasis: No suture hole bleeding PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Construction Water permeabilit y Wall thickness** Burst strength** 45°suture retention** Ultrathin Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.35 mm 35.3 kg/cm 2 1.83 kg * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. 1. INTERGARD*** Collagen Coated Knitted Vascular Grafts: Results of the U.S. Clinical Trial 2. Manougian S. Prosthetic below-knee femoropopliteal bypass grafting. Late results with the INTERGARD Ultrathin vascular prosthesis. Zentralbl Chir 2000; 125:280-285 *** F ormally known as the established brand “INTERGARD”, this knitted prosthesis is now rebranded as “HEMAGARD”. | 12 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | KNITTED VASCULAR PRODUCTS HEMAGARD KNITTED ultrathin graft ULTRATHIN radially supported STRAIGHT Diameter 6 mm 7 mm 8 mm 6 mm 7 mm 8 mm Proximal / Distal Length 35/15 cm 35/15 cm 35/15 cm 25/15 cm 25/15 cm 25/15 cm Supported Length 20 cm 20 cm 20 cm 30 cm 30 cm 30 cm Total Length 70 cm 70 cm 70 cm 70 cm 70 cm 70 cm Reference HGKUT0006RS20 HGKUT0007RS20 HGKUT0008RS20 HGKUT0006RS30 HGKUT0007RS30 HGKUT0008RS30 ULTRATHIN straight 40 cm length: Diameter 6 mm 7 mm 8 mm 70 cm length: Reference HGKUT0006-40 HGKUT0007-40 HGKUT0008-40 Diameter 6 mm 7 mm 8 mm Reference HGKUT0006-70 HGKUT0007-70 HGKUT0008-70 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 13 | KNITTED VASCULAR PRODUCTS HEMAGARD PATCH KNITTED Material: HEMAGARD PATCH properties: C ollagen-coated polyester patch S uperb handling and suturability Reverse locknit knitting technique Water permeability : ≤ 5ml . cm . min -2 No suture hole bleeding -1 PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Construction Water permeabilit y Wall thickness** HEMAGARD Patch Knitted Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.65 mm * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. W ide range of sizes KNITTED Dimensions 25 mm x 50 mm 25 mm x 75 mm 25 mm x 150 mm 25 mm x 100 mm 50 mm x 50 mm 50 mm x 75 mm 50 mm x 150 mm 75 mm x 75 mm 100 mm x 100 mm Reference HGK25/50P (1) HGK25/75P (1) HGK25/150P (1) HGK25/100P (1) HGK50/50P (1) HGK50/75P (1) HGK50/150P (1) HGK75/75P (1) HGK100/100P (1) | 14 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | KNITTED VASCULAR PRODUCTS HEMAGARD CAROTID PATCH KNITTED Material: C ollagen-coated polyester patch Reverse locknit knitting technique Water permeability : ≤ 5ml . cm -2 . min -1 HEMAGARD CAROTID patch properties: S uperb handling and suturability N o suture hole bleeding PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Construction Water permeabilit y Wall thickness** HEMAGARD CAROTID Patch Knitted Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.65 mm * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. KNITTED Dimensions 6 mm x 75 mm 8 mm x 75 mm 10 mm x 75 mm 12 mm x 75 mm 14 mm x 75 mm 6 mm x 75 mm 8 mm x 75 mm 10 mm x 75 mm 12 mm x 75 mm 14 mm x 75 mm Tapered Yes Yes No No No Yes Yes No No No Reference HGKTP06/75CP (1) HGKTP08/75CP (1) HGK10/75CP (1) HGK12/75CP (1) HGK14/75CP (1) HGKTP06/75CP (10) HGKTP08/75CP (10) HGK10/75CP (10) HGK12/75CP (10) HGK14/75CP (10) Units Per Box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 10 units per box 10 units per box 10 units per box 10 units per box 10 units per box | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 15 | KNITTED VASCULAR PRODUCTS HEMAGARD CAROTID PATCH KNITTED ULTRATHIN Material: C ollagen-coated polyester patch Reverse locknit knitting technique Water permeability : ≤ 5ml . cm -2 . min -1 Wall thickness of 0.41mm HEMAGARD CAROTID PATCH properties: Proprietary Ultrathin wall technology D esigned to enhance patch performance O ffers superb handling and conformability to host vessels E xcellent healing with no suture hole bleeding PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Construction Water permeabilit y Wall thickness** Burst strength** HEMAGARD CAROTID Patch Ultrathin Cross-linked Type I bovine collagen Knitted, reverse locknit ≤ 5ml • cm -2 • min -1@120 mmHg 0.41 mm 35.3 kg/cm 2 * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. KNITTED ULTRATHIN Dimensions 6 mm x 75 mm 8 mm x 75 mm 8 mm x 150 mm 10 mm x 75 mm 12 mm x 75 mm 14 mm x 75 mm 6 mm x 120 mm 8 mm x 120 mm 25 mm x 75 mm 25 mm x 150 mm 6 mm x 75 mm 8 mm x 75 mm 10 mm x 75 mm 12 mm x 75 mm 14 mm x 75 mm Tapered Yes Yes Yes No No No Yes Yes No No Yes Yes No No No Reference HGKTP06/75CPUT (1) HGKTP08/75CPUT (1) HGK TP08/150CPUT (1) HGK10/75CPUT (1) HGK12/75CPUT (1) HGK14/75CPUT (1) HGKTP06/120CPUT (1) HGKTP08/120CPUT (1) HGK25/75CPUT (1) HGK25/150CPUT (1) HGKTP06/75CPUT (10) HGKTP08/75CPUT (10) HGK10/75CPUT (10) HGK12/75CPUT (10) HGK14/75CPUT (10) Units Per Box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 1 unit per box 10 units per box 10 units per box 10 units per box 10 units per box 10 units per box | 16 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | WOVEN VASCULAR PRODUCTS Hemashield Platinum Woven DOUBLE VELOUR VASCULAR GRAFTS Material: Uncompromised handling: Soft, flexible material. Woven double velour impregnated polyester graft D esigned to conform to host vessel for easy anastomosis* Porosity < 5 ml/min/cm S mooth needle passage and excellent suture retention is 2 designed to reduce bleeding at the anastomosis Excellent healing: Excellent long term biocompatibility Highly compliant material promotes a snug fit at the and durability*. anastomosis Promotes formation of a smooth, thin pseudointima* Excellent hemostasis: Patented impregnation process. Improves graft patency* D esigned to provide controlled resorption for uniform Patented Hemashield PLATINUM collagen impregnation tissue ingrowth* process provides graft porosity of < 5 ml/min/cm 2 Straight tubes over 15 cm usable length: Diameter 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 38 mm Order Number M00202175112P0 M00202175114P0 M00202175116P0 M00202175118P0 M00202175120P0 M00202175122P0 M00202175124P0 M00202175126P0 M00202175128P0 M00202175130P0 M00202175132P0 M00202175134P0 M00202175138P0 Bifurcations over 30 cm usable length: Diameter 6 mm 7 mm 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 38 mm Order Number M00202175206P0 M00202175207P0 M00202175208P0 M00202175210P0 M00202175412P0 M00202175414P0 M00202175416P0 M00202175418P0 M00202175420P0 M00202175422P0 M00202175424P0 M00202175426P0 M00202175428P0 M00202175430P0 M00202175432P0 M00202175434P0 M00202175438P0 *Measurements and testing completed by MAQUET Cardiovascular LLC. Data on file. Bench test results may not necessarily be indicative of clinical performance. over 60 cm usable length: Diameter 6 mm 7 mm 8 mm 10 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 38 mm Order Number M00202175406P0 M00202175407P0 M00202175408P0 M00202175410P0 M00202175620P0 M00202175622P0 M00202175624P0 M00202175626P0 M00202175628P0 M00202175630P0 M00202175632P0 M00202175634P0 M00202175638P0 over 40 cm usable length: Diameter 12 mm x 6 mm 14 mm x 7 mm 14 mm x 8 mm 16 mm x 8 mm 16 mm x 9 mm 18 mm x 9 mm 18 mm x 10 mm 20 mm x 10 mm 20 mm x 11 mm 22 mm x 11 mm 24 mm x 12 mm Order Number M00202166126P0 M00202166147P0 M00202166148P0 M00202166168P0 M00202166169P0 M00202166189P0 M00202166180P0 M00202166201P0 M00202166211P0 M00202166221P0 M00202166241P0 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 17 | WOVEN VASCULAR PRODUCTS Hemashield Platinum WOven Aortic Branch GRAFTS Material: Woven double velour impregnated polyester graft Porosity < 5 ml/min/cm 2 AORTIC ARCH Single Branch AORTIC ARCH 4 Branch 50 cm usable length: 50 cm usable length: Thoracic Size 20 mm x 50 cm 22 mm x 50 cm 24 mm x 50 cm 26 mm x 50 cm 28 mm x 50 cm 30 mm x 50 cm 32 mm x 50 cm 34 mm x 50 cm Branch Size 10 mm 10 mm 10 mm 10 mm 10 mm 10 mm 10 mm 10 mm Order Number M00202175820P0 M00202175822P0 M00202175824P0 M00202175826P0 M00202175828P0 M00202175830P0 M00202175832P0 M00202175834P0 Thoracic Size 20 mm x 50 cm 22 mm x 50 cm 24 mm x 50 cm 26 mm x 50 cm 28 mm x 50 cm 30 mm x 50 cm 32 mm x 50 cm 34 mm x 50 cm Branch Size 10, 10, 8, 8 mm 10, 10, 8, 8 mm 10, 10, 8, 8 mm 10, 10, 8, 8 mm 10, 10, 8, 8 mm 10, 10, 8, 8 mm 12, 10, 10, 10 mm 12, 10, 10, 10 mm ANGLED FOUR BRANCH thoraco abdominal aortic graft 50 cm usable length: 47 cm usable length: Thoracic Size 24 mm x 50 cm 26 mm x 50 cm 28 mm x 50 cm 30 mm x 50 cm Branch Size 12, 10, 8, 8 mm 12, 10, 8, 8 mm 12, 10, 8, 8 mm 12, 10, 8, 8 mm Order Number M00202175724AP0 M00202175726AP0 M00202175728AP0 M00202175730AP0 Thoracic Size 26 mm x 47 cm 28 mm x 47 cm 30 mm x 47 cm 32 mm x 47 cm * Made on request only 3 BRANCH GRAFT 30 cm usable length, porosity < 10 ml/min/cm 2 : Thoracic Size 12 mm x 30 cm 14 mm x 30 cm Branch Size 8 mm 10 mm Order Number M002021759120 M002021759140 Branch Size 10, 10, 8, 8 mm 10, 10, 8, 8 mm 10, 10, 8, 8 mm 10, 10, 8, 8 mm Order Number M00202175920P0 M00202175922P0 M00202175924P0 M00202175926P0 M00202175928P0 M00202175930P0 M00202175732P0 M00202175734P0 Order Number *M00202175426T0 *M00202175428T0 *M00202175430T0 *M00202175432T0 | 18 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | WOVEN VASCULAR PRODUCTS CARDIOROOT: THE INNOVATIVE AORTIC ROOT GRAFT The innovative one piece-design collagen-coated CARDIOROOT graft delivers a new option for the repair or reconstruction of the ascending aorta. The unique design of CARDIOROOT mimics the anatomy and blood flow dynamics of the natural sinuses of Valsalva. xpect the same high quality offered by MAQUET E - Market leader in Thoracic grafts O utstanding handling and suturability A natomically correct shape valve remnants anastomosis 3 References lines acting as a guide for prosthetic valve or nique uncrimped section that does not stretch: U - Allows easy sewing of valve remnants, or prosthetic valve Bore within the tube, avoiding potential bleeding and shortening the procedure - Facilitates estimation of the length required for optimal placement of valve remnants or prosthetic valve to Body ensure optimal clinical outcomes - Can be precisely trimmed and shaped in case of remodeling technique proceduress Bulge Collar CARDIOROOT Body Diameter 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm Body Length 15 cm 15 cm 15 cm 15 cm 15 cm 15 cm Bulge Diameter 32 mm 34 mm 36 mm 38 mm 40 mm 42 mm Bulge Length 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm Collar Length 10 mm 10 mm 10 mm 10 mm 10 mm 10 mm Order Number HEWROOT0024 HEWROOT0026 HEWROOT0028 HEWROOT0030 HEWROOT0032 HEWROOT0034 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 19 | WOVEN VASCULAR PRODUCTS INTERGARD woven Material: % of those who described handling as “Excellent”: C ollagen-coated external-velour polyester graft Water permeability : ≤ 5ml . cm -2 . min -1 85.7% n=96 – INTERGARD WOVEN INTERGARD Woven properties: E xcellent strength and long-term durability 32.7%, n=33 – CONTROL GRAFTS (gelatin sealed and collagen impregnated grafts) Healing: E xternal velour only to provide a smooth foundation to promote secure pseudointima growth and minimize thrombus formation 0 10 20 30 40 50 60 70 80 90 100 handling criteria1 Handling: E xclusive weave design produces woven grafts that handle 1. Marc Schepens, MD, St. Antonius Hospital, Nieuwegein, Netherlands, Comparison of Woven Collagen Coated Vascular Grafts in the Thoracic Position. and suture like a knitted graft Excellent strength and suturing characteristics PHYSICAL AND MECHANICAL PROPERTIES* Hemostasis: No suture hole bleeding Coated polyester fabric Water permeabilit y Wall thickness** 45°suture retention** Woven Cross-linked Type I bovine collagen ≤ 5ml • cm -2 • min -1@120 mmHg 0.38 mm 2.53 kg * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. | 20 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | WOVEN VASCULAR PRODUCTS INTERGARD woven Straight tubes 15 cm length: Diameter 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm Reference IGW0012-15 IGW0014-15 IGW0016-15 IGW0018-15 IGW0020-15 IGW0022-15 *IGW0024-15 *IGW0026-15 *IGW0028-15 *IGW0030-15 *IGW0032-15 *IGW0034-15 IGW0036-15 * Made on request only BIFURCATED 50 cm length: Diameter 12 x 6 mm 14 x 7 mm 16 x 8 mm 18 x 9 mm 20 x 10 mm 22 x 11 mm 24 x 12 mm Reference IGW1206 IGW1407 IGW1608 IGW1809 IGW2010 IGW2211 IGW2412 30 cm length: Diameter 6 mm 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm 34 mm 36 mm 38 mm Reference IGW0006-30 IGW0008-30 IGW0010-30 IGW0012-30 IGW0014-30 IGW0016-30 IGW0018-30 IGW0020-30 IGW0022-30 IGW0024-30 IGW0026-30 IGW0028-30 IGW0030-30 IGW0032-30 IGW0034-30 IGW0036-30 IGW0038-30 60 cm length: Diameter 22 mm 24 mm 26 mm 28 mm 30 mm 32 mm Reference IGW0022-60 IGW0024-60 IGW0026-60 IGW0028-60 IGW0030-60 IGW0032-60 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 21 | WOVEN VASCULAR PRODUCTS INTERGARD woven AORTIC ARCH Material: C ollagen-coated external-velour polyester graft Water permeability : ≤ 5ml . cm -2 . min -1 INTERGARD Woven Aortic Arch properties: Pre-sewn branches designed for total replacement of all diseased segments, and to allow reduced cardiac ischemic time A natomically correct angle of branches is designed for easy suturing to the host vessels and to prevent graft kinking 3 0 cm length perfusion branch designed to be positioned outside of the operative field for improved control and visualization PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Water permeabilit y Wall thickness** 45°suture retention** Woven Cross-linked Type I bovine collagen ≤ 5ml • cm -2 • min -1@120 mmHg 0.38 mm 2.53 kg * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. AORTIC ARCH Diameter (mm) 20x10x8x8x10 22x10x8x8x10 24x10x8x8x10 26x10x8x8x10 28x10x8x8x10 30x10x8x8x10 32x10x8x8x10 34x10x8x8x10 Length (cm) 50x30x30x30x30 50x30x30x30x30 50x30x30x30x30 50x30x30x30x30 50x30x30x30x30 50x30x30x30x30 50x30x30x30x30 50x30x30x30x30 Reference HEWA A2010080810/1 HEWA A2210080810/1 HEWA A2410080810/1 HEWA A2610080810/1 HEWA A2810080810/1 HEWA A3010080810/1 HEWA A3210080810/1 HEWA A3410080810/1 | 22 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | WOVEN VASCULAR PRODUCTS INTERGARD woven HEMABRIDGE Material: C ollagen-coated external-velour polyester graft Water permeability : ≤ 5ml . cm -2 . min -1 INTERGARD HEMABRIDGE properties: D esigned to allow an easier, more reliable, and less time consuming technique Pre-sewn perfusion branch allow for antegrade arterial perfusion, and can be used to replace the brachiocephalic artery in a partial arch replacement PHYSICAL AND MECHANICAL PROPERTIES* Coated polyester fabric Water permeabilit y Wall thickness** 45°suture retention** Woven Cross-linked Type I bovine collagen ≤ 5ml • cm -2 • min -1@120 mmHg 0.38 mm 2.53 kg * Testing performed per ANSI/AAMI ISO 7198:1998/2001. ** Test results are for customer evaluation only and do not represent a product specification. HEMABRIDGE Diameter 20 mm x 10 mm 22 mm x 10 mm 24 mm x 10 mm 26 mm x 10 mm 28 mm x 10 mm 30 mm x 10 mm 32 mm x 10 mm 34 mm x 10 mm Length 35 cm x 40 cm 35 cm x 40 cm 35 cm x 40 cm 35 cm x 40 cm 35 cm x 40 cm 35 cm x 40 cm 35 cm x 40 cm 35 cm x 40 cm Reference HEW2010BRIDGE HEW2210BRIDGE HEW2410BRIDGE HEW2610BRIDGE HEW2810BRIDGE HEW3010BRIDGE HEW3210BRIDGE HEW3410BRIDGE | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 23 | WOVEN VASCULAR PRODUCTS Hemashield DOUBLE VELOUR Fabrics Material: Woven double velour impregnated polyester fabric Porosity: < 10ml/min/cm 2 Excellent handling and strength: Proprietary Hemashield collagen impregnation process provides an initial blood-tight seal, excellent tissue ingrowth and biocompatibility E xclusive double velour material offers very good handling and strength Woven fabric construction provides an excellent match to the clinical demands of abdominal, peripheral and thoracic applications Hemashield Woven Double Velour Fabric Width x Length (inch) 1.0 x 6.0 2.0 x 3.0 2.0 x 6.0 Width x Length (cm) 2.5 x 15.2 5.1 x 7.6 5.1 x 15.2 Order Number M002000196170 M002000196240 M002000196270 Specifications: Porosity: <10cc/min/cm2. Nominal Thickness: 0.46 mm. | 24 | Vascular and Cardiothoracic Surger y Solutions | Cardiovascular | OTHER PRODUCTS Polyester Tape Material: B raided polyester fabric Effective retraction: S trong, tight braided polyester fabric designed to reduce risk of tissue trauma while providing effective retraction Sterile Width x Length (inch) 1/8 x 18.0 1/8 x 24.0 1/8 x 30.0 3/16 x 18.0 3/16 x 24.0 3/16 x 30.0 1/4 x 18.0 1/4 x 24.0 1/4 x 30.0 Non-Sterile Width x Length (cm) 0.32 x 45.7 0.32 x 61.0 0.32 x 76.2 0.48 x 45.7 0.48 x 61.0 0.48 x 76.2 0.64 x 45.7 0.64 x 61.0 0.64 x 76.2 Order Number M002000194310 M002000194320 M002000194330 M002000194410 M002000194420 M002000194430 M002000194510 M002000194520 M002000194530 Specifications: Packaged 2 strips per package. Packaged 1 per box. Width x Length 1/8 x 100 (in x yd) 3/16 x 100 (in x yd) 1/4 x 100 (in x yd) Width x Length 3.2 x 91.4 (mm x m) 4.8 x 91.4 (mm x m) 6.4 x 91.4 (mm x m) Specifications: Packaged 1 spool per box. Order Number M002000194000 M002000194100 M002000194200 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 25 | OTHER PRODUCTS graft sizer Single use plastic sizers for graft measurement prior to implantation. Small graft sizer Diameter (mm) 5-24 Multipack 10 units per pack Order Number M002363200201 large graft sizer Diameter (mm) 24-38 Multipack 10 units per pack Order Number M002363200211 | Cardiovascular | Vascular and Cardiothoracic Surger y Solutions | 27 | KNOWING WHAT’S IMPORTANT THE SURGICAL ACADEMY As a communication center the MAQUET Surgical Academy offers a variety of specialist events on topics relating to medi- cine, health policy, and hospital management. An exhibition hall with the complete product range, two auditoria with multimedia equipment, four conference rooms as well as fully equipped and functional operating and intensive care rooms are among the infrastructure at this unique facility. In workshops, experts in small groups communicate valua ble findings for everyday clinical work. Practice-oriented teaching materials supplement the offering, for example a positioning primer which explains the rudiments of surgical positioning step-by-step. Inhouse product trainings for worldwide MAQUET business partners ensure a permanent high level of knowledge and the ability of excellent customer support. GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions. GETINGE provides solutions for infection control within healthcare and contamination prevention within life sciences. MAQUET specializes in solutions, therapies and products for surgical interventions, interventional cardiology and intensive care. 0558 Rev A MAQUET Cardiovascular LLC 45 Barbour Pond Drive Wayne, NJ 07470 www.maquet.com/vascular Additional Contact Address Label Here ® MAQUET Registered Trademark of MAQUET GmbH & Co. KG · Copyright MAQUET Cardiovascular LLC or its affiliates. All rights reserved. 004/12. Atrium Medical Corporation 5 Wentworth Drive Hudson, NH 03051 Phone: (+1) 603-880-1433 Fax: (+1) 603-880-6718 www.atriummed.com
© Copyright 2024