For Sales queries write to: [email protected] MODEL NO: -DLPL RFPM DEOS LABS HANDHELD RF POWER METER www.deoslabs.com www.deoslabs.com www.deoslabs.com www.deoslabs.com Key Features • • • • • • Broad 1GHz to 8 GHz frequency range enables use in variety of devices working in L, S, C and Extended C band. Large dynamic range of -40 dBm to 0 dBm measures various types of signals, either directly from the device under test or through layers of cabling and fixtures Integrated power sensor eliminates the need to carry a separate sensor and makes it the most compact and portable RF power meter instrument Internal power reference enables self-calibration and excludes the need to perform independent calibration before using the instrument Absolute accuracy up to +/- 1 dB enables more precise characterization of devices, tighter test limits and more accurate fixture calibration Accurate RMS power measurement of signals with high peak-to-average ratios DEOS DLPL RFPD handheld RF power meter is a compact, portable instrument that makes lab quality RF power measurements in both field and R&D laboratory environments. With an absolute accuracy of up to +/- 1 dB, a wide frequency range of 1 GHz to 8 GHz, and measurement range of -40 dBm to 0 dBm, the DLPL RFPD is suitable for a wide variety of RF measurement applications. It’s built in power sensors eliminates the need for users to carry both an instrument and a separate sensor module, and the same sensor is used when duplicating tests or measurements for better repeatability. Truly portable, the DLPL RFPD fits easily into your hand or a toolkit and optional loop holster carrying case with shoulder strap is also available to fit your need. To optimize flexibility, it is capable of drawing operating power from batteries or an ACDC converter module. With its features and very attractive price, the DLPL RFPD truly redefines superior value. High Accuracy in both the Lab and the Field Whether it’s used in the field or the factory floor, the DEOS DLPL RFPD makes lab quality RF measurements quickly and easily. Its absolute accuracy up to +/- 1 dB, enables more precise characterization of devices, tighter test limits, and more accurate fixture calibration. In the laboratory, it can be used as an RF power data- logger. Using its built-in serial port it easily transfer data to your personal computer through the cable provided, allowing for trend or drift analysis. Despite its small package the DEOS DLPL RFPD provides outstanding accuracy on the bench, replacing much larger and more expensive instrumentation. www.deoslabs.com www.deoslabs.com www.deoslabs.com www.deoslabs.com Serial Port Take a Closer Look RF Connector In the RF world, cables are often equipped with N-connectors and SMA connectors. Nconnectors are commonly used on test instrumentation, because they are rugged, can handle high powers, and perform well up to about 18 GHz. This section contains information about how to make RF signal connections to the type N male RF connector (50Ω characteristic impedance) of the DLPL RFPD for power measurement. Connection for a Power Measurement The power meter has a built-in serial port (DB9 connector) configured as null modem at 9600 Bits per second. The DLPL RFPD can be remotely accessed over this serial interface. External power connector The power connector provides a connection for the optional external power supply. If the external power supply is connected, the DLPL RFPD will be powered by the external supply, regardless of whether batteries are present or not. Caution: Only connect the optional external power supply (DLPL RFPD-PWR) to this connector. Instrument damage may result if improper power is applied. Battery Power Note: When connecting the type N connector of the DLPL RFPD to a type N female connector for power measurement, observe the following proper practice for tightening the connection. While holding the body of the power meter in one hand, turn the type N male connector nut to tighten the connection (do not turn the body of DLPL RFPD). Continue to do so until the connection is hand tight. It is important to turn the nut out of the connector rather then the body of the power meter when tightening the connection. The DLPL RFPD can also be powered by two AA batteries. If installed, the batteries will power the DLPL RFPD only if the external power supply is not connected. Graphic Display 128 X 64 Pixel Resolutions Graphic LCD with Blue Backlight. Keypad Capacitive Touch Keypad. No Mechanical Wear and Tear Shock Proof Robust and Durable Easy to handle and clean www.deoslabs.com Operating Temperature Range -40 to 850 C www.deoslabs.com www.deoslabs.com www.deoslabs.com A P • • • • RADARS VSAT New installations Troubleshooting • • R&D and design verifications Measurement of RF power at different points • • Production Testing Measurement of RF power at different stage of production • • • Mobile tower New Installations Troubleshooting P L I C A T I O N S www.deoslabs.com www.deoslabs.com www.deoslabs.com www.deoslabs.com
© Copyright 2024