TCG 2015 for stationary applications 164 - 240 kW|220 - 322 hp at 1500 - 1800 min-1|rpm US EPA 40CFR60, stationary only Water-cooled V6 and V8 engines with- Easy installation: Turn-key solution with turbocharging, charge air cooling andfour-valve technology. single cooling circuit and low space claim due to the very compact engine design. Complete gas train and engine monitor- Gear driven fan-hub and flexible cooling ing system for natural gas operation. options lead to reduced maintenance and installastion costs. Individual cylinder heads, wet cylinder liners, long oil change intervals and easy changing of the engine fluids reduce the running and service costs and increase the availability of the machinery. Strong base engine well proved in many applications under toughest conditions. Technical data Engine type No. of cylinders Bore/stroke Displacement Weight (without cooler and fan) TCG 2015 V6 6 132/145 | 5.2/5.7 11.9 | 727 995 |2194 TCG 2015 V8 8 132/145 | 5.2/5.7 15.9 | 969 1290 |2844 kW | hp kW | hp TCG 2015 V6 164 |220 153 |206 TCG 2015 V8 220 |295 209 |281 kW | hp kW | hp TCG 2015 V6 180 |241 162 |217 TCG 2015 V8 240 |322 222 |298 mm | in l | cu in kg | lb 1500 rpm (50 Hz) Power1) Gross power (no fan) Net flywheel 1800 rpm (60 Hz) Power1) Gross power (no fan) Net flywheel 1) Power (kW) according to ISO 14396. The data on this data sheet are for information purposes only and are not binding values. The data in the quotation is definitive. 1500 rpm (50 Hz) Fuel comsuption1) Fuel comsuption 50% load Fuel comsuption 75% load Fuel comsuption 100% load Heat balance & cooling system Heat dissipation (engine radiator)2) Heat dissipation (convection) Fan power consumption Inlet & exhaust data max. intake depression Combustion air volume max. exhaust gas temperature Exhaust gas flow g/kWh | lb/hph g/kWh | lb/hph g/kWh | lb/hph TCG 2015 V6 235 |0.39 220 |0.36 214 |0.35 TCG 2015 V8 240 |0.39 229 |0.38 222 |0.36 kW | hp kW | hp kW | hp TCG 2015 V6 168 |225 9 |12 11 |14 TCG 2015 V8 225 |302 12 |16 11 |14 mbar | psi m3/h | cfm °C | °F m3/h | cfm TCG 2015 V6 50 |0.73 762 |448 450 |842 1817 |1069 TCG 2015 V8 55 |0.8 1125 |662 450 |842 2690 |1583 g/kWh | lb/hph g/kWh | lb/hph g/kWh | lb/hph TCG 2015 V6 258 |0.42 233 |0.38 223 |0.35 TCG 2015 V8 262 |0.43 236 |0.39 230 |0.38 kW | hp kW | hp kW | hp TCG 2015 V6 185 |248 10 |13 18 |24 TCG 2015 V8 247 |331 13 |18 18 |24 mbar | psi m3/h | cfm °C | °F m3/h | cfm TCG 2015 V6 50 |0.73 859 |506 450 |842 2050 |1207 TCG 2015 V8 55 |0.8 1323 |779 450 |842 3162 |1861 1800 rpm (60 Hz) Fuel comsuption1) Fuel comsuption 50% load Fuel comsuption 75% load Fuel comsuption 100% load Heat balance & cooling system Heat dissipation (engine radiator)2) Heat dissipation (convection) Fan power consumption Inlet & exhaust data max. intake depression Combustion air volume max. exhaust gas temperature Exhaust gas flow Order No. 0031 2511 / 03 / 2014 / MC-M 1) Refers to dry natural gas, methane number >70, lower calorific value 9,832 kWh/m³. 2) The heat quantities are valid for the dimensioning of the cooling system. Dimensions C B TCG 2015 V6 TCG 2015 V8 A mm | in mm | in A 1410 |55.5 1575 |62.0 B 1110 |43.7 1110 |43.7 C 1745 |68.7 1745 |68.7 Note: The engine dimensions and weights vary depending on the scope of delivery. For more information please contact the DEUTZ AG Köln or the responsible sales partner. DEUTZ AG ⋅ Ottostraße 1 ⋅ 51149 Köln ⋅ Deutschland ⋅ Telefon +49 (0) 221 822-0 ⋅ Telefax +49 (0) 221 822-3525 ⋅ www.deutz.com ⋅ E-Mail: [email protected]
© Copyright 2024