1800 min-1|rpm US EPA 40CFR60, stationary only

TCG 2015
for stationary applications
164 - 240 kW|220 - 322 hp at 1500 - 1800 min-1|rpm
US EPA 40CFR60, stationary only
 Water-cooled V6 and V8 engines with-
 Easy installation: Turn-key solution with
turbocharging, charge air cooling andfour-valve technology.
single cooling circuit and low space
claim due to the very compact engine
design.
 Complete gas train and engine monitor-
 Gear driven fan-hub and flexible cooling
ing system for natural gas operation.
options lead to reduced maintenance
and installastion costs.
 Individual cylinder heads, wet cylinder
liners, long oil change intervals and
easy changing of the engine fluids reduce the running and service costs and
increase the availability of the machinery.
 Strong base engine well proved in
many applications under toughest conditions.
Technical data
Engine type
No. of cylinders
Bore/stroke
Displacement
Weight (without cooler and fan)
TCG 2015 V6
6
132/145 | 5.2/5.7
11.9 | 727
995 |2194
TCG 2015 V8
8
132/145 | 5.2/5.7
15.9 | 969
1290 |2844
kW | hp
kW | hp
TCG 2015 V6
164 |220
153 |206
TCG 2015 V8
220 |295
209 |281
kW | hp
kW | hp
TCG 2015 V6
180 |241
162 |217
TCG 2015 V8
240 |322
222 |298
mm | in
l | cu in
kg | lb
1500 rpm (50 Hz)
Power1)
Gross power (no fan)
Net flywheel
1800 rpm (60 Hz)
Power1)
Gross power (no fan)
Net flywheel
1) Power (kW) according to ISO 14396.
The data on this data sheet are for information purposes only and are not binding values. The data in the quotation is definitive.
1500 rpm (50 Hz)
Fuel comsuption1)
Fuel comsuption 50% load
Fuel comsuption 75% load
Fuel comsuption 100% load
Heat balance & cooling system
Heat dissipation (engine radiator)2)
Heat dissipation (convection)
Fan power consumption
Inlet & exhaust data
max. intake depression
Combustion air volume
max. exhaust gas temperature
Exhaust gas flow
g/kWh | lb/hph
g/kWh | lb/hph
g/kWh | lb/hph
TCG 2015 V6
235 |0.39
220 |0.36
214 |0.35
TCG 2015 V8
240 |0.39
229 |0.38
222 |0.36
kW | hp
kW | hp
kW | hp
TCG 2015 V6
168 |225
9 |12
11 |14
TCG 2015 V8
225 |302
12 |16
11 |14
mbar | psi
m3/h | cfm
°C | °F
m3/h | cfm
TCG 2015 V6
50 |0.73
762 |448
450 |842
1817 |1069
TCG 2015 V8
55 |0.8
1125 |662
450 |842
2690 |1583
g/kWh | lb/hph
g/kWh | lb/hph
g/kWh | lb/hph
TCG 2015 V6
258 |0.42
233 |0.38
223 |0.35
TCG 2015 V8
262 |0.43
236 |0.39
230 |0.38
kW | hp
kW | hp
kW | hp
TCG 2015 V6
185 |248
10 |13
18 |24
TCG 2015 V8
247 |331
13 |18
18 |24
mbar | psi
m3/h | cfm
°C | °F
m3/h | cfm
TCG 2015 V6
50 |0.73
859 |506
450 |842
2050 |1207
TCG 2015 V8
55 |0.8
1323 |779
450 |842
3162 |1861
1800 rpm (60 Hz)
Fuel comsuption1)
Fuel comsuption 50% load
Fuel comsuption 75% load
Fuel comsuption 100% load
Heat balance & cooling system
Heat dissipation (engine radiator)2)
Heat dissipation (convection)
Fan power consumption
Inlet & exhaust data
max. intake depression
Combustion air volume
max. exhaust gas temperature
Exhaust gas flow
Order No. 0031 2511 / 03 / 2014 / MC-M
1) Refers to dry natural gas, methane number >70, lower calorific value 9,832 kWh/m³.
2) The heat quantities are valid for the dimensioning of the cooling system.
Dimensions
C
B
TCG 2015 V6
TCG 2015 V8
A
mm | in
mm | in
A
1410 |55.5
1575 |62.0
B
1110 |43.7
1110 |43.7
C
1745 |68.7
1745 |68.7
Note: The engine dimensions and weights vary depending on the scope of delivery.
For more information please contact the DEUTZ AG Köln or the responsible sales partner.
DEUTZ AG