What we do... A market leading range of voltage optimization systems Sell solutions – not boxes Engineering led business Fully supportive, turnkey solution Our clients include… Powerstar provides the main power Palace of Westminster House of Keys-Isle of Man Welsh Assembly All Cabinet Office Buildings London City Hall Western Australia Parliament Why Voltage Optimization? Voltage optimization is needed to purely correct supply issues caused by the HV infrastructure. What does voltage optimization do? What does voltage optimization do? The Table above is been extracted from ANSI C84.1 (American National Standard for Electric Power and Equipment). It clearly shows that although the Nominal Voltage is 480V, motors are designed for 460V. With an average voltage of 493V, the specific savings in terms of energy and reduction in maintenance costs by providing a regulated 455-460V supply could be significant. How is the voltage in the USA? The equipment in the USA should operate from 418V to 509V (ideal voltage is 455V-460V) and the voltage at this installation is 485V to 497V. The Green line is the fully electronically regulated output of the Powerstar MAX system. Basically we take the voltage from the electricity authority, we chop the excess and we send back to them (the electricity authority) the amount we don’t need. This creates negative power which goes towards the supply and reduces the electrical consumption of the site. 70%-80% of the savings come from the negative voltage feedback and 20%-30% from equipment efficiency improvements. What do the Universities say? POWERSTAR VIRTUE Powerstar Virtue harnesses the induced negative power generated by the Powerstar technology to charge a storage medium Energy generated during periods of low demand can be stored locally and used when required Powerstar Virtue allows users to become a virtual power station, reliably forecasting how much will be available at all times and make informed decisions on how and when stored energy should be used HOW POWERSTAR VIRTUE WORKS POWERSTAR VIRTUE - PRODUCT BENEFITS Maximise savings by storing electricity locally Reduce costs by coming off grid at times of high tariff Eliminate risk of network interruption Guarantee stable and reliable power at all times Make your facility grid independent at any time Integrate with onsite renewables to maximise cost benefits Eliminate user of inverters on renewables Reduce costs of renewable installations Full site UPS support capability for up to 2 hours Become a virtual power station and participate in grid incentive schemes (Is worth to $200,000 per year per MW in the United Kingdom) Reduce maintenance costs of onsite electrical equipment 100% savings guarantee from the Powerstar system still applies EFFECTS ON LOAD PROFILE Electricity profile before Virtue Installation EFFECTS ON LOAD PROFILE Electricity profile after Virtue Installation EFFECTS ON LOAD PROFILE WITH SOLAR Electricity profile of a site with a solar installation before Virtue EFFECTS ON LOAD PROFILE WITH SOLAR Electricity profile of a site with a solar installation after Virtue. The Virtue system has been configured to completely remove the store from the grid at peak times only and remove the site from the grid for 4 hours a day EFFECTS ON LOAD PROFILE WITH SOLAR Electricity profile of a site with a solar installation after Virtue. Virtue has been programmed to completely remove the site from the grid at peak times and never allow the site to exceed 100 kWh of demand. Complete Powerstar Virtue + Renewabl e Solution, can be provided as a single package. Why is it important to optimize site voltage? In addition, VO helps with Targets, obligations, pressures… Reduce kWh Reduce CO2 Reduce maintenance costs CRC, CSR Save money Why is it important to optimize site voltage? Worsening Power quality issues, including: Transients Harmonics Phase imbalance Poor power factor A number of these issues (harmonics, transients) are significantly on the increase mainly due to energy efficiency and renewables. Optimizing voltage and affects on harmonics Improves Harmonics The graph below shows the Harmonic Levels before and after VO installation. Optimizing voltage also improves power factor Improves Power Factor The graph below shows the power factor before and after VO installation in a supermarket. How does Voltage Optimization help? Reduces kWh Consumption Motors Name-plate rating for 3-phase motors is commonly 480V. NEMA stipulate that a motor should operate normally for: - Voltage range +/- 10% of the nameplate voltage (see label above 440V to 480V) Effect of voltage variation on motors Voltage unbalance Winding insulation life is approximately halved for every 10 Degrees Celcius in winding temperature Motor losses increase 25% with a 4% unbalance voltage Savings of 3 Phase 30kW Motor with Powerstar for US & UK Supply 25 No Load 20 Energy Savings (%) - 50% 15 - 70% Lightly Loaded - 90-95% 10 Heavy Loaded 5 Tap 3 Tap 2 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 Voltage Reduction (%) US Supply UK Supply 7.0 8.0 Tap 4 9.0 10.0 11.0 Optimize at LV side High voltage side Low voltage side POWERSTAR OR POWERSTAR MAX Optimize at the HV side High voltage side POWERSTAR HV MAX Low voltage side Do you own your HV/LV Transformer? The choice should be clear. The reason you want to optimise is to remove the problems created by the HV infrastructure Unless your HV/LV distribution transformer is brand new, correct the issues at source. Optimise the voltage at the HV supply. Simply replacing the existing, inefficient HV/LV transformer with the super low loss Powerstar HV MAX. * Chart from the USA department of energy 1993 Real time monitoring The Powerstar HMI (Human Machine Interface) can be viewed online and/or through an internal network and is IP addressable. In addition the system stores the following information every ten minutes and has a huge storage capacity: Display of energy savings Current per phase kVA per phase Total kVA kWh per phase Total kWh Voltage per phase KVAr per phase Power Factor per phase Harmonics (both Voltage and Current) Installation (LV) ASDA Walmart Powerstar HV MAX Savings HV CONNECTED AND ACTIVATED 5.4% savings due to the replacement of the transformer with the super low loss amorphous core Powerstar HV MAX POWERSTAR AND ELECTRONICS (MAX) ACTIVATED Additional 13.8% savings when low voltage was activated Warranty & Guarantee Powerstar comes with up to 10 years warranty Our warranty includes parts and labor We guarantee the minimum savings as per our proposal If minimum savings are not achieved we will provide payment to compensate for the difference between your actual savings and the guaranteed savings You have nothing to lose as your payback is always guaranteed Case studies and testimonials An American healthcare company HV MAX installation into healthcare company with primary operational focus on products to treat haemophilia, kidney disease, immune disorders and other chronic and acute medical conditions Average consumption by half hour comparing pre and post Powerstar HV MAX install • Savings (kWh) • % Savings • Annual savings • Payback period Total daily emissions (CO2) pre and post Powerstar HV MAX installation 458,272 12% £51,213 3 years • Following the installation annual electricity consumption was reduced by 8.3% • 189.8 tonnes of carbon emissions were reduced per annum following installation London City Hall Home of the Greater London Authority accommodates the Mayor of London, the London Assembly and 600 or so permanent GLA employees.. % Savings: 13.6% London Stock Exchange After a comprehensive review of the existing voltage optimization systems sold in the UK, the London Stock Exchange chose Powerstar to power their critical services. % Savings: 13.6 Guoman Hotels Group Ltd – Thistle Hyde Park • Total before (kWh) (24 days) • Total after (kWh) (24 days) • Savings (kWh) • % Savings • Annual savings based on 8p/kWh 34355.3 25403.8 8951.5 26.1% $18,309 “So far the Powerstar installations in our hotels have achieved as much as an amazing 26.1% saving in total electricity consumption at our Thistle Hyde Park Hotel and elsewhere, never less than an 11.5% saving.” David Hannah, Head of Property, Guoman Hotels Group Ltd Department for Business Innovation & Skills Seven Powerstar units were installed into BIS, the results of five of these installations are shown below. Two of the units currently have no data for savings as BIS changed the meter and have not had data since. Annual energy consumption reduction and cost savings • Unit 1: • Unit 2: • Unit 3: • Unit 4: • Unit 5: 24.7% reduction / $13,562 saving 11.3% reduction / $5,700 saving 13.65% reduction / $7,627 saving 8.59% reduction / £11,092 saving 6.2% reduction / $13,792 saving NHS – Ashworth Hospital The hospital were looking for a reliable system to effectively reduce high energy costs and consumption caused by lighting, plant & IT equipment in the hospital. Following the installation of four Powerstar units the hospital is benefiting from the following savings: • Savings (kWh) • % Savings • Annual savings • Payback period 458,272 12% $86,099 3 years NHS - West Middlesex University Hospital West Middlesex University Hospital have reduced their energy consumption by 8.4% on the two transformers fitted with the Powerstar voltage optimisation system. The energy saving equates to 163.6 tonnes of saved carbon dioxide. University of Surrey The University of Surrey has held sustainability at the heart of its CSR agenda for over a decade. The campus is home to 17,900 students and 2,597 staff and views investing in sustainable technology as a critical component. • Savings (kWh) • % Savings • Annual savings • Payback period 189,474 8.1% $23,387 3 years Charles F Stead Charles F Stead is one of the most respected tanners of suede leather in the world today. Post install, electrical equipment at Charles F Stead is running more efficiently and impressive savings have been achieved. Year on year savings present a 20.74% kWh energy reduction. The Co-operative Group Powerstar voltage optimisation systems have been successfully installed into a number of Co-operative Food group stores, providing substantial savings. Plymouth is the first ‘All VO City’ with all Co-Operative food stores benefiting from Powerstar. A summary of the benefits can be seen on the table below: Whitbread Group Plc “As a responsible hotel and restaurant business, we need to ensure our customers enjoy a good nights sleep and great tasting menus served in a relaxed atmosphere. We found Powerstar to be both professional and proactive in their awareness of the installation requirements during business operational hours, which ensured minimum disturbance for our guests. We have now installed more than 400 Powerstar systems in our estates and the carbon savings are fantastic. It is the equivalent of removing the emissions of 24,000 UK households from the National Grid. A great result for our company, and the environment.” Chris George, Head of Energy and Environment at Whitbread hotels & restaurants “We have been very pleased with the quality and workmanship from the team at EMSc (UK) Ltd – the energy savings have been higher than forecast and we are expecting to run a phase 2. EMSc have been very flexible in scoping, design and working around our operational units to ensure full services were maintained. I have no hesitation in recommending Voltage Optimisation (Powerstar) from EMSc (UK) Ltd and we are pleased with the full service EMSc provided.” Stuart Harris, Head of Energy and Carbon Operations, BT Technology Service & Operations ASDA – Walmart Supermarkets “Powerstar voltage optimisation has been a major part of our comprehensive energy efficiency programme. It is perhaps the simplest and most effective way to instantly save energy and therefore we would highly recommend Powerstar systems.” Mark Orpin, Head of Energy Management, ASDA Supermarkets RWE npower “We arranged a test of the Powerstar unit, utilising a 3rd party company to measure the claims of EMSc (UK) Ltd against one of our buildings. The tests were carried out over a 6 week period and during that time EMS Powerstar’s estimated savings were not only met but surpassed. We also measured the harmonics and power factor and again they surpassed expectations. We now have Powerstar installed across the majority of our larger office portfolio and are showing savings every day. One other thing for me was the working relationship and technical advice that we received from EMS Powerstar. Both myself and the company I used to collect and analyse the test data thought EMS Powerstar an excellent company to work with, providing clear and prompt advice on savings, installations and recommendations. The icing on the cake was the fact the equipment was all UK manufactured and it was custom built for our older sites which had restricted space in our distribution rooms. We have also looked at EMS Powerstar’s domestic systems which potentially could help many of our customers reduce their energy bills. Dave Horton, RWE npower, Sustainability and Capital Investments Manager Powerstar are npower and EON selected partners. Can we help? YES, we can… If you are not sure what to do to reduce your energy consumption, contact us and we can organise a free no-obligation proposal. E-mail us at [email protected] Visit: www.powerstar.com
© Copyright 2024