A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. OPENING SINGLE TRACK LINTEL FIXING NOTE:- AN ADDITIONAL STUD IS REQUIRED POSITIONED WITHIN 150mm (min) AND 225mm (max) EITHER SIDE OF ALL STRUCTURAL OPENINGS FOR A MASONARY FACADE PROJECT FOR BRICK TIE CHANNEL FIXING JAMB STUD 100mm LONG SWAGED CRIPPLE TRACK FIXED TO JAMB STUD USING 3 No 5.5 x 25mm TEK SCREWS (EOS02) SIN GL E LINTEL/CILL TRACK FIXED INTO CRIPPLE TRACK USING 2 No 5.5 x 25 TEK SCREWS (WAFER HEADS) (EOS05) ONE FIXING CENTRALLY INTO EACH FLANGE. TR AC KL IN TE SIN GL E 100mm LONG SWAGED CRIPPLE TRACK FIXED TO JAMB STUD USING 3No 5.5 x 25 TEK SCREWS (EOS02) L TR AC KC ILL JAMB STUD OPENING SINGLE TRACK CILL FIXING BA Title: TYPICAL OPENING - SINGLE TRACK LINTEL & CILL CONNECTION DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Scale: n.t.s. Drawing No. Revision: 261 A Approved By: Date: SE T RA CK DRAWING INDICATIVE ONLY: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. NOTE:- AN ADDITIONAL STUD IS REQUIRED POSITIONED WITHIN 150mm (min) AND 225mm (max) EITHER SIDE OF ALL STRUCTURAL OPENINGS FOR A MASONARY FACADE PROJECT FOR BRICK TIE CHANNEL FIXING 100mm LONG CRIPPLE TRACK FIXED TO JAMB STUD USING 3 No 5.5 x 25mm TEK SCREWS (EOS02) LIN OPENING SINGLE JAMB AND DOUBLE STUD LINTEL FIXING TE L TR AC K JAMB STUD SWAGED DOUBLE STUD LINTEL / CILL FIXED INTO CRIPPLE TRACK USING 2 No 5.5 x 25mm TEK SCREWS (WAFER HEADS) (EOS05) ONE FIXING CENTRALLY INTO EACH FLANGE. DOUBLE STUD LINTEL / CILL FORMED FROM 2 No. STUDS CONNECTED BY NOGGINS @ 600mm c/c. WITH TRACK TOP OR BOTTOM DOUBLE STUD LINTEL / CILL FIXED TOGETHER USING 5.5 x 25mm TEK SCREWS (WAFER HEADS) (EOS05) 4 FIXINGS PER NOGGIN. DOUBLE STUD LINTEL / CILL FIXED TO LINTEL & CILL TRACK USING 5.5 x 25mm TEK SCREWS (EOS02) @ 600mm CENTRES. JAMB STUD 100mm LONG CRIPPLE TRACK FIXED TO JAMB STUD USING 3No 5.5 x 25mm TEK SCREWS (EOS02) CIL L DOUBLE STUD LINTELS / CILLS MANUFACTURED ONSITE BY INSTALLERS OR OFFSITE IN EOS FACTORY (PROJECT SPECIFIC) OPENING SINGLE JAMB AND DOUBLE STUD CILL FIXING Title: BA TYPICAL OPENING - SINGLE JAMB & DOUBLE STUD LINTEL & CILL CONNECTION DETAIL (S & T) SE T RA CK STAGE: Preliminary: Approval: Construction: Drawn By: Scale: n.t.s. Drawing No. Revision: 262 A Approved By: Date: TR AC K DRAWING INDICATIVE ONLY: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. NOTE:- DOUBLE STUDS ARE STANDARDLY MANUFACTURED AT 100mm WIDE HOWEVER THEY CAN BE MANUFACTURED WIDER TO ENCAPSULATE THE ADDITIONAL STUD AS REQUIRED TO BE POSITIONED WITHIN 150mm (min) AND 225mm (max) EITHER SIDE OF ALL STRUCTURAL OPENINGS FOR A MASONARY FACADE PROJECT FOR BRICK TIE CHANNEL FIXING LIN 100mm LONG CRIPPLE TRACK FIXED TO JAMB STUD USING 3No 5.5 x 25mm TEK SCREWS (EOS02) TE L TR AC K OPENING DOUBLE STUD JAMB AND DOUBLE STUD LINTEL FIXING DOUBLE JAMB STUD SWAGED DOUBLE STUD LINTEL / CILL FIXED INTO CRIPPLE TRACK USING 2 No 5.5 x 25mm TEK SCREWS (WAFER HEADS) (EOS05) ONE FIXING CENTRALLY INTO EACH FLANGE. DOUBLE STUD LINTEL / CILL FORMED FROM 2 No. STUDS CONNECTED BY NOGGINS @ 600mm c/c. WITH TRACK TOP OR BOTTOM DOUBLE STUD LINTEL / CILL FIXED TOGETHER USING 5.5 x 25mm TEK SCREWS (WAFER HEADS) (EOS05) 4 FIXINGS PER NOGGIN. DOUBLE STUD LINTEL / CILL FIXED TO LINTEL & CILL TRACK USING 5.5 x 25mm TEK SCREWS (EOS02) @ 600mm CENTRES. DOUBLE JAMB STUD 100mm LONG CRIPPLE TRACK FIXED TO JAMB STUD USING 3 No 5.5 x 25mm TEK SCREWS (EOS02) CIL L DOUBLE STUD & DOUBLE STUD LINTELS / CILLS MANUFACTURED ONSITE BY INSTALLERS OR OFFSITE IN EOS FACTORY (PROJECT SPECIFIC) OPENING DOUBLE STUD JAMB AND DOUBLE STUD CILL FIXING Title: BA TYPICAL OPENING - DOUBLE STUD JAMB & DOUBLE STUD LINTEL & CILL CONNECTION DETAIL (S & T) SE T RA CK STAGE: Preliminary: Approval: Construction: Drawn By: Scale: n.t.s. Drawing No. Revision: 263 A Approved By: Date: TR AC K DRAWING INDICATIVE ONLY: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. A HE D K AC TR AD HE K AC TR HEAD FIXING DEFLECTION HEAD FIXING DOUBLE STUD MANUFACTURED ONSITE BY INSTALLERS OR OFFSITE IN EOS FACTORY (PROJECT SPECIFIC) DOUBLE STUDS CONNECTED USING NOGGINS FIXED WITH 4 No. 5.5 x 25mm TEK SCREWS (EOS05) NOGGINS AT 600mm CENTRES. BASE FIXING NOTE:- DOUBLE STUDS ARE STANDARDLY MANUFACTURED AT 100mm WIDE HOWEVER THEY CAN BE MANUFACTURED WIDER TO ENCAPSULATE THE ADDITIONAL STUD AS REQUIRED TO BE POSITIONED WITHIN 150mm (min) AND 225mm (max) EITHER SIDE OF ALL STRUCTURAL OPENINGS FOR A MASONARY FACADE PROJECT FOR BRICK TIE CHANNEL FIXING CK RA T SE BA Title: TYPICAL DOUBLE STUD CONNECTION DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Scale: n.t.s. Drawing No. Revision: 265 A Approved By: Date: DRAWING INDICATIVE ONLY: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. DOUBLE JAMB STUD AND LATTICE LINTEL FABRICATED ONSITE BY INSTALLERS OR OFF SITE BY EOS (PROJECT SPECIFIC). LA TT IC LATTICE FIXED TO DOUBLE STUD USING 4 No 5.5 x 25mm TEK SCREWS (EOS02) EL IN TE L DOUBLE JAMB STUD WITH SHORTENED INNER STUD TO PROVIDE BEARING FOR LATTICE. LATTICE DEPTH TO SUIT HEIGHT BETWEEN WINDOW HEAD AND FLOOR / ROOF ABOVE. AD HE BEARING NOGGING FIXED TO DOUBLE STUD USING 4 No. 5.5 x 25mm TEK SCREWS (WAFER HEADS) (EOS05) LATTICE FIXED TO BEARING USING 2 No 5.5 x 25mm TEK SCREWS (EOS02) Title: TYPICAL LATTICE LINTEL DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Scale: n.t.s. Drawing No. Revision: 266 A Approved By: Date: OF G IN EN P O DRAWING INDICATIVE ONLY: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. NOTE : Orientation of studs 2 & 3 must be web to web facing 50mm x 1mm Flat strap to run across full bay. 2 No fixings into each stud. Strap to be fitted on Internal face of Studs at all times. Cloaking Track 1 2 3 Cripple track fixed onto the back web of the vertical stud. Track then cloaks the two cripple tracks and fixed as shown Plan on Typical Corner Step 1 Step 3 Step 2 2 No fixings EOS S & T site fix (EOS 05) Flat plate runs full length of bay. 50mm x1mm thk, 1 No fixing into flange of stud EOS S&T Site fixings (EOS 05) Track cloaks cripple tracks EOS S&T site fixing into both flanges (EOS 05) Cripple Track Strap to be fitted to track 2 No fixings (EOS 05) This detail is to be used in all situations where a mid-height restraint is required. Length of mid-height restraint to be specified by Engineer. Stud Size and Spacing to be Job Specific specified by EOS Title: TYPICAL STUD AND TRACK MID HEIGHT RESTRAINT DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Scale: n.t.s. Drawing No. Revision: 269 A Approved By: Date: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. NOTE:- SLAB NOT SHOWN FOR CLARITY. PLEASE USE DEFLECTION HEAD DETAIL 211 TO CONNECT STUD TO HEAD TRACK THIS DETAIL CAN BE ADOPTED FOR VENT OPENINGS UP TO THE MAXIMUM SIZE AVAILABLE BETWEEN THE STUDS AT THE REQUIRED CENTRES FOR OTHER SIZES PLEASE CONSULT EOS ENGINEERS TYPICAL VENT OPENING ELEVATION THE HEAD TRACK CAN BE CUT OUT LOCALLY IF IT CLASHES WITH THE VENT HOWEVER PLEASE ENSURE THAT A FIXING IS PLACED A MAXIMUM OF 50mm AWAY FROM EACH END OF TRACK OPENING TRACK FIXED INTO CRIPPLE TRACK USING 2 No 5.5 x 25mm TEK SCREWS (WAFER HEADS) (EOS05) ONE FIXING CENTRALLY INTO EACH FLANGE. TR AC KF OR MI NG OP EN IN G JAMB STUD 100mm LONG SWAGED CRIPPLE TRACK FIXED TO JAMB STUD USING 3 No 5.5 x 25mm TEK SCREWS (EOS02) Title: TYPICAL VENT OPENING CONNECTION DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Drawing No. Scale: n.t.s. 270 Revision: Approved By: Date: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. DEFLECTION BRACKETS ARE NOT REQUIRED ON THE STUDS ABOVE THE OPENING FOR A HARD FIXED LINTEL - DEFLECTION IS TO BE ALLOWED FOR ABOVE THE WINDOW WINDOW MANUFACTURER TO ALLOW ADDITIONAL TOLERANCE FOR MOVEMENT / DEFLECTION ABOVE THE HEAD OF THE WINDOW TYPICAL HARD FIXED LINTEL ELEVATION Head track (Fixing to suit structure) TYPICAL SECTION Alternative fixing position. mm minimum. NOTE:- PROJECT SPECIFIC HARD FIXED LINTEL DETAILS WILL BE PROVIDED DURING DESIGN REVIEW WITH AN EOS ENGINEERS AS ADDITIONAL BRACKETRY OR WINDPOSTS MAY BE REQUIRED FOR LARGER OPENINGS Vertical stud Lintel track WINDOW MANUFACTURER TO ALLOW ADDITIONAL TOLERANCE FOR MOVEMENT / DEFLECTION ABOVE THE HEAD OF THE WINDOW Title: TYPICAL HARD FIXED LINTEL CONNECTION DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Drawing No. Scale: n.t.s. 271 Revision: Approved By: Date: A4 TOLERANCES: Construction tolerances between frames is -0mm +2mm. Frames are manufactured and assembled to +0mm -2mm. HE AD TR AC K Head track fixed to Wind Post Double Stud each side using 4.8mm dia. Tek screws (wafer heads) (EOS05) Wind Post Double stud HEAD FIXING WIND POST DOUBLE STUD MANUFACTURED OFFSITE IN EOS FACTORY (100mm WIDE) Wind Post Double Stud fixed to Wind Post Base Plate using 4 No. 4.8mm dia. Tek screws (wafer heads) (EOS05) each side Wind Post Double stud EOS base track securely fixed to concrete floor using Tapcon fixings (EOS21) @ centres to suit wind loading. Note:- fixing to be 50mm maximum from end of track BASE FIXING SE BA TR A CK Windpost Baseplate - EOS Engineer to confirm project specific fixing requirements NOTES 1. Fixing provided as required for windloading restraint. 2. Installer to confirm line and level of track base prior to fixing and report deviations greater than +/- 15mm. 3. Each track length to have fixing 50mm from each end. Title: TYPICAL PARAPET WIND POST CONNECTION DETAIL (S & T) STAGE: Preliminary: Approval: Construction: Drawn By: Drawing No. Scale: n.t.s. 272 Revision: Approved By: Date:
© Copyright 2024