Submission of this form will be received by a Franklin Electric Irrigation & Industrial Surface Application Engineer. RMA Number SURFACE PUMP INSTALLATION DATA Form 2208 - Page 1 PUMP MODEL DESCRIPTION Catalog number: _____________________________________ Horsepower: ________________________________________ Model description: ___________________________________ Impeller diameter: ____________________________________ Pump serial number: _________________________________ Installation date: _____________________________________ PUMP DISTRIBUTOR INSTALLING CONTRACTOR END USER Name: ___________________________ Name: ___________________________ Name: ___________________________ Street: ___________________________ Street: ___________________________ Street: ___________________________ City: _____________________________ City: _____________________________ City: _____________________________ State: ___________ Zip: ____________ State: ___________ Zip: ____________ State: ___________ Zip: ____________ Contact: _________________________ Contact: _________________________ Contact: _________________________ Phone: ___________________________ Phone: ___________________________ Phone: ___________________________ email: ____________________________ email: ____________________________ email: ____________________________ DESCRIPTION OF PROBLEM Performance: ________________________________________ Mechanical: _________________________________________ Describe: ___________________________________________ Describe: ___________________________________________ SYSTEM INFORMATION Required head (at pump discharge):_____________________ ____________________ Flooded suction Suction lift Parallel operation Series operation Pump operating speed: __________________ Describe pump’s primary function: _____________________ Pumpage if other than water @ 60 °-70 °F: ______________ SYSTEM CHECKS CORRECT SUCTION PIPING PRACTICES FOLLOWED Close as possible to pump’s BEP (80-120%) Read pump installation & owner’s manual Proper horsepower Speed Voltage Phase Rotates freely No obstruction/blockage/damage with impeller Packing adjusted per instructions Adequate water supply Adequate NPSHA (must exceed NPSHR) Pump as near water source as possible Pump primed/do not allow pump to run dry Suction pipe at least one commercial pipe size larger than pump suction Velocity not to exceed 8 ft./sec. pipe diameter Avoid long suction pipe run Eccentric reducer used for pipe size transition with straight side up No air leaks in piping High spots avoided Foot valve or suction screen not obstructed/blocked or stuck from bottom Standard or long radius elbows used/not directly in front of pump inlet Suction gauge installed not less that 18" from pump inlet port Pipe supported as required CORRECT DISCHARGE PIPING PRACTICES FOLLOWED Correct pipe size used throughout system Concentric reducer used for pipe size transition Use of non-slam check valves Discharge pressure gauge installed not less than 18" from pump discharge port Isolation valves used/open during operation Pipe supported as required MOTOR/ELECTRICAL Supply voltage matches motor nameplate Measured amps @ motor under system conditions Voltage reading @ motor: Static voltage (pump not running): ___ Dynamic voltage (pump running): ____ Motor wired correctly ____ft of AWG wire size #____ between the service entrance and motor All state/local electrical codes followed Form No. 2208 v0 08/11 © 2011 Franklin Electric Co., Inc. This material may be reproduced in its entirety for personal and educational purposes, including reproduction in technical specifications and manuals, without prior permission, provided that the above copyright notice is included in all copies or substantial portions of the material. All other rights reserved. SURFACE PUMP INSTALLATION DATA RMA Number Form 2208 - Page 2 IRRIGATION SUCTION LIFT Discharge Friction Losses Pressure Discharge Head Total Discharge Head Vertical Elevation Total Dynamic Head Centrifugal Pump Static suction lift: ______________________________________ Suction system friction losses: ___________________________ Static Suction Lift Total suction lift: _ ______________________________________ Total Suction Lift Pressure discharge head (converted to feet): ______________ Vertical elevation: _ _____________________________________ Suction Friction Losses Discharge system friction losses: _________________________ Total discharge head: ___________________________________ Total dynamic head (TDH): _ _____________________________ OPEN TANK DISCHARGE Discharge Friction Losses Open Tank Total Discharge Head Static Discharge Head Total Dynamic Head Centrifugal Pump Static suction lift: ______________________________________ Static Suction Lift Suction system friction losses: ___________________________ Total suction lift: _ ______________________________________ Total Suction Lift Suction Friction Losses Static discharge head: __________________________________ Discharge system friction losses: _________________________ Total discharge head: ___________________________________ Total dynamic head (TDH): _ _____________________________ Form No. 2208 v0 08/11 © 2011 Franklin Electric Co., Inc. This material may be reproduced in its entirety for personal and educational purposes, including reproduction in technical specifications and manuals, without prior permission, provided that the above copyright notice is included in all copies or substantial portions of the material. All other rights reserved. SURFACE PUMP INSTALLATION DATA RMA Number Form 2208 - Page 3 CLOSED TANK DISCHARGE Discharge Friction Losses Total Discharge Head Pressure Dischagre Head Closed tank with 50 psi average pressure Total Dynamic Head Centrifugal Pump Static suction lift: ______________________________________ Static Suction Lift Suction system friction losses: ___________________________ Total Suction Lift Total suction lift: _ ______________________________________ Suction Friction Losses Pressure discharge head (converted to feet): ______________ Discharge system friction losses: _________________________ Total discharge head: ___________________________________ Total dynamic head (TDH): _ _____________________________ FLOODED SUCTION LIFT Discharge Friction Losses Suction Friction Losses Open Tank Total Dynamic Head Pressure Discharge Head Static Suction Head Total Negative Suction Lift Closed tank with 50 psi average pressure Static suction head (negative lift): _ _______________________ Less suction system friction losses: _ _____________________ Total (negative) suction lift: _ _____________________________ Centrifugal Pump Pressure discharge head (converted to feet): ______________ Discharge system friction losses: _________________________ Total discharge head: ___________________________________ Total dynamic head (TDH): _ _____________________________ Form No. 2208 v0 08/11 © 2011 Franklin Electric Co., Inc. This material may be reproduced in its entirety for personal and educational purposes, including reproduction in technical specifications and manuals, without prior permission, provided that the above copyright notice is included in all copies or substantial portions of the material. All other rights reserved.
© Copyright 2024