FD25 PDF - FRP Architectural Doors

Product Specifications: FRP Architectural Doors Inc. FD25 Standard Wall Door Series
Part 1
General – Division 8 - Section 08255 Flush FRP Entrance Doors
1.1 Section Includes
A. Fiberglass Faced (FRP) flush doors.
B. Aluminum Frames
1.2 Related Sections
A. Section 08710
B. Section 08800
1.3 Reference Listings
A. AAMA A440
B. AAMA 920
C. AAMA 925
D. AAMA 1503
E. ASTM B 209
F. ASTM B 221
G. ASTM D 256
H. ASTM D 543
I. ASTM D 683
J. ASTM D 790
K. ASTM D 1308
L. ASTM D 1621
M. ASTM D 1623
N. ASTM D 2126
O. ASTM D 2583
P. ASTM D 5420
Q. ASTM E 84
R. ASTM E 283
S. ASTM E 330
T.
ASTM E 331
Door Hardware
Glass and Glazing
Air, Water, Structural.
Operating Cycle Performance.
Determining the Vertical Loading Resistance.
Thermal Transmittance and CRF.
Aluminum Alloy and Aluminum Sheet and Plate.
Aluminum Alloy Extruded Bars, Rods, Profiles and Tubes.
Determining the Pendulum Impact Resistance of Notched Specimens of Plastics.
Evaluating the Resistance of Plastics to Chemical Reagents.
Tensile Properties of Plastics.
Flexural Properties of Unreinforced and Reinforced Plastic Materials.
Effects of Household Chemicals on Clear and Pigmented Organic Finishes.
Compressive Properties of Rigid Cellular Plastics.
Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics.
Response of Rigid Cellular Plastics to Thermal and Humid Aging.
Indentation Hardness of Rigid Plastics by means of Barcol Impresser.
Impact Resistance of Flat Rigid Plastic by Means of Falling Weight.
Surface Burning Characteristics of Building Materials.
Determining the rate of air leakage through exterior windows and doors.
Structural Performance of Exterior Windows and Doors by Uniform Static Air
Pressure Difference.
Water Penetration of Exterior Windows and Doors by Uniform Static Air Pressure
Difference.
1.4 Performance Requirements
A. Provide door assemblies that have been designed and fabricated to comply with specified
performance requirements as demonstrated by testing manufacture’s corresponding standard
systems.
B. Air Infiltration- Single door and frame test specimen 3’0” x 7’0” shall be tested using
AAMA A440-08-11 specifications in accordance with ASTM E 283 pressure differential.
C. Structural Performance- Single door and frame test specimen 3’0” x 7’0” shall be tested using
AAMA A440-08-11 specifications in accordance with ASTM E 330 uniform static air pressure.
D. Water Resistance- Single door and frame test specimen 3’0” x 7’0” shall be tested using
AAMA A440-08-11 specifications in accordance with ASTM E 331 pressure differential.
Phone: 215-604-1545
FRP ARCHITECTURAL DOORS INC.
501 Cambria Ave-Suite 102 Bensalem, Pa. 19020
www.FRPARCH.com
E.
Thermal Transmission and CRF, Exterior Doors. Doors shall have a U-Value and a CRF Value per
specification AAMA 1503.
F. Surface Burning Characteristics; ASTM E 84; FRP fiberglass for Doors and Panels shall be:
1. Flame Spread:
Maximum of 200, Class C.
2. Smoke Developed: Maximum of 450, Class C.
G. Izod Impact Strength; FRP Fiberglass for Doors and Panels shall have an ASTM D256 nominal value of
14.0 ft-lb/in notched.
H. Tensile Strength; FRP Fiberglass for Doors and Panels shall have an ASTM D638 value of 13 x 103 psi.
I. Tensile Modulus; FRP Fiberglass for Doors and Panels shall have an ASTM D638 value of 1.2 x 106 psi.
J. Flexural Strength; FRP Fiberglass for Doors and Panels shall have an ASTM D790 value of 21 x 103 psi.
K. Tensile Modulus; FRP Fiberglass for Doors and Panels shall have an ASTM D790 value of 0.7 x 106 psi.
L. Water Absorption; FRP Fiberglass for doors and Panels shall have an ASTM D570 value of
0.20%/24hrs@770F.
M. Gardner Impact Strength; FRP Fiberglass for Doors and Panels shall have an ASTM D3029 value of
120 in-lb.
N. Taber Abrasion Resistance; FRP Fiberglass for Doors and Panels shall have a C-17 wheel, 1000g.
Taber Test; 0.01% Maximum Weight Loss after 25 cycles.
O. Stain Resistance; FRP Fiberglass for Doors and Panels shall be tested in accordance to ASTM D1308
standards and remain unaffected after exposure to food products and stains are to be easily removed
with mild abrasive or FRP cleaner.
P. Chemical Resistance; FRP Fiberglass for Doors and Panels shall have an Excellent Rating when tested in
accordance to ASTM D543 standards.
Q. Polystyrene Insulation option for Doors and Panels shall have be a nominal density of 2Lb. pcf
(25lb psi) and have a thermal resistance nominal R-Value of 6.3.
R. Urethane Insulation option for Doors and Panels shall have a nominal in place density of 5lb. pcf and
have an aged thermal resistance nominal R-Value of 9.
S. Thermal Barrier, IBC, Bocca code core liner sheet option for doors will be a single .032 sheet
aluminum liner placed between the layer of core insulation and the inside door face sheet.
T. Compressive Strength of Urethane foam core, Nominal Value, ASTM D 1621: 80 psi
U. Compressive Modulus of Urethane foam core, Nominal Value, ASTM D 1621: 140 psi
V. Tensile Adhesion of Urethane foam core, Nominal Value, ASTM D 1623: 60 psi
W. Thermal and Humid Aging of Urethane foam core, Nominal Value, ASTM D 2126: Less than 2% Volume
Change.
Part 2 Products
2.1 Provide door assemblies that have been designed and fabricated to comply with specified
performance requirements as demonstrated by testing manufacture’s corresponding standard
systems.
2.2 Manufacturer
A. FRP Architectural Doors Inc. - 215-604-1545 - www.FRPARCH.com
B. Approved Equal – Subject to compliance with product requirements and the owner’s decision of a
requested substitution.
2.3 FRP Flush Entrance Doors
A. Standard Wall Door Series FD25; 1-3/4” thick flush door with fiberglass reinforced polyester (FRP)
face sheets.
B. Door trim, vision lights and internal sub-frame stiles and rails are constructed of extruded tubular
aluminum shapes using billet aluminum, grade 6063 and a T6 tempered alloy.
C. Door perimeter edge trim, top and bottom are applied to the doors sub-frame.
D. Construction Components:
1. Sub-Frame stiles and rails.
FRP ARCHITECTURAL DOORS INC.
Phone: 215-604-1545
501 Cambria Ave-Suite 102 Bensalem, Pa. 19020
www.FRPARCH.com
a.
2.
3.
4.
5.
6.
Top and bottom horizontal rails; full 6” rectangular tube full 6”with 1/8” wall thickness
with tie-rod spline.
b. Lock and hinge vertical stiles; full 2 ½” extrusion with integral edge trim.
c. Flange channel hardware reinforcing; full 2 ½” with 1/8” wall thickness.
d. Lock and hinge stiles have integral locking edges that secure the face edge at the seams.
e. Corner joint assembled using monumental type mortise and tenon joinery with 3/8” tie-rods
thru splines.
Perimeter trims are aluminum shapes and are finished to anodize or paint as selected.
a. Top and Bottom trims have tee-slot to accept for weather-seal. Bottom trim supplied with
pile weather-seal.
b. Lock and hinge edge stiles are beveled with tee-slot pile weather-seal.
Core Insulation will be expanded urethane foam injected in place to fill voids between stiles and
rails. Core to be 5lb. in place density and have an R-value of 9.
Face Sheet to be fiberglass reinforced polyester (FRP) with an abuse resistant surface and U.V.
additives to aide in the protection against normal weathering and normal usage.
a. Face Sheet to be .120 Thickness
b. Standard Face sheet to be color throughout. Custom color optional face sheets to be
specially designed to accept specially formulated paint products, color to match
selected color.
c. Face sheet to have patterned pebble embossed texture.
Vision Light (cut-outs) to be specifically made to accept options for ¼” or 1” Glass. Glass types are
determined under the related glass and glazing sections.
Factory Hardware preparation options are required for reinforcing and preparations of mortised
and concealed hardware. Surface hardware may be applied in the field as required per related
hardware sections.
Phone: 215-604-1545
FRP ARCHITECTURAL DOORS INC.
501 Cambria Ave-Suite 102 Bensalem, Pa. 19020
www.FRPARCH.com