DEMOLITION GENERAL NOTES NOTE THAT, FOR CLARITY, SOME NEW CONTRUCTION (NON-DEMOLITION) WORK IS DESCRIBED IN THE FOLLOWING NOTES. 1. REFER TO THE GENERAL NOTES ON THE COVER SHEET OF THESE DRAWINGS FOR ADDITIONAL REQUIREMENTS. 2. COORDINATE ALL DEMOLITION WORK WITH THE OTHER WORK OF THE PROJECT AND WITH THE REQUIREMENTS OF ALL SUBCONTRACTORS FOR THE SUCCESSFUL COMPLETION OF THEIR WORK. 3. REFER TO THE ARCHITECTURAL, STRUCTURAL, SITE/CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS AS APPLICABLE FOR SPECIFIC INFORMATION, DIMENSIONS, LOCATIONS, ETC. REGARDING THE EXACT EXTENT OF DEMOLITION REQUIRED. 4. COORDINATE WITH THE MECHANICAL, PLUMBING, AND ELECTRICAL CONTRACTORS REGARDING THEIR SELECTIVE DEMOLITION OF EXISTING EQUIPMENT AND COMPONENTS. 5. ALL EXISTING EQUIPMENT, FIXTURES, AND COMPONENTS TO BE REMOVED (INCLUDING BUT NOT LIMITED TO: DOORS, DOOR FRAMES, DOOR HARDWARE, RADIATORS, BOILERS, LIGHT FIXTURES, PEWS, ETC.) AND IDENTIFIED BY THE OWNER TO BE SAVED SHALL BE CAREFULLY REMOVED SO AS NOT TO DAMAGE OR MAR THE ITEM, TRANSPORTED BY THE CONTRACTOR TO THE OWNER'S STORAGE AREA, UNLOADED, AND TURNED OVER TO THE OWNER. ALL OTHER REMOVED ITEMS AND DEBRIS ARE TO BE LEGALLY DISPOSED OF BY THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER REGARDING THE OWNER'S SELECTION OF EXISTING ITEMS TO BE SAVED (AS DESCRIBED ABOVE) AND REGARDING THE OWNER'S STORAGE AREA. P (317)951-9590 F (317)951-9690 6. WHERE EXISTING FASTENERS, ANCHORS, ETC. ARE LEFT EXPOSED BY THE REMOVAL OF ADJACENT CONSTRUCTION, FIXTURES, ETC., REMOVE OR CUT-OFF THESE EXISTING ELEMENTS TO A DEPTH SUFFICIENT TO ALLOW FOR CONCEALMENT BY NEW CONSTRUCTION AND/OR TO ALLOW FOR PROPER PATCHING OF THE EXISTING ADJACENT CONSTRUCTION, MATERIAL, AND/OR FINISH TO REMAIN. COORDINATE WITH THE APPROPRIATE TRADES. COORDINATE WITH RELATED WORK AS DESCRIBED IN THESE CONSTRUCTION DRAWINGS. 7. COORDINATE WORK DESCRIBED IN THESE DEMOLITION GENERAL NOTES, THE DEMOLITION PLAN KEY NOTES BELOW, THE GENERAL NOTES (FOUND ON THE COVER SHEET), AND THE BALANCE OF THESE CONSTRUCTION DRAWINGS. 8. AT EXISTING AREAS SCHEDULED TO RECEIVE NEW FLOOR FINISHES: FILL, PATCH, AND LEVEL ALL HOLES, BLEMISHES, DEPRESSIONS, ABANDONED PENETRATIONS, ETC. (WHETHER EXISTING OR RESULTING FROM DEMOLITION) AS REQUIRED TO ESTABLISH A SMOOTH, UNIFORM, LEVEL SURFACE FLUSH WITH THE ADJACENT EXISTING SURFACE AND APPROPRIATE TO RECEIVE THE SCHEDULED NEW FINISH FLOORING MATERIALS, INCLUDING NEW UNDERLAYMENT. 3 REMOVE THE EXISTING WOOD WAINSCOT AND ASSOCIATED WOOD CAP TRIM. REFER TO APPLICABLE DETAIL REGARDING MODIFICATION TO ADJACENT WOOD CAP TRIM TO REMAIN. 4 ALL THE EXISTING PEWS (INCLUDING PEW SCREENS) ARE TO BE REMOVED AND STORED OFF-SITE IN ORDER TO FACILITATE THE FLOOR AND WALL WORK IN THE NAVE. (PRIOR TO THE REMOVAL OF THE PEWS, THE G.C. IS TO CAREFULLY LABEL EACH PEW AND DOCUMENT ITS EXACT EXISTING LOCATION. THE OWNER WILL PROVIDE CLIMATE-CONTROLLED WAREHOUSE SPACE IN BRAZIL, IN. THE OWNER WILL PROVIDE THE MANPOWER REQUIRED TO MOVE THE PEWS, LOAD THE TRUCK (BOTH WAYS), UNLOAD THE TRUCK (BOTH WAYS), AND MOVE THE PEWS BACK INTO THE CHURCH. REMOVE, PROTECT, AND RE-INSTALL THE EXISTING HOLY WATER BLESSING FONT. MATCH EXISTING MOUNTING HEIGHT AND LOCATION. A. B. REMOVE, PROTECT, AND RE-INSTALL EXISTING AUTO DOOR OPERATOR PUSHBUTTON. MATCH EXISTING MOUNTING HEIGHT AND LOCATION. D. EXISTING GROUT AT FLOOR TO REMAIN. PROTECT FROM DAMAGE. E. F. 10 IN THIS EXISTING ROOM CONTAINING THE SHRINE, THE PARISH IS TO REMOVE THE EXISTING STATUARY AND ALL LOOSE FURNISHINGS AND STORED MATERIALS. SACRISTY 106 7 8 9 7 1 2 3 8 9 4 5 7 7 6 8 9 7 8 9 10 8 11 9 7 12 13 14 8 9 7 15 6 REMOVE THE EXISTING WOOD PANELING FROM THE EXISTING PLASTER WALL SURFACE TO REMAIN, INCLUDING THE HORIZONTAL INTERIOR WINDOW SILL. REMOVE THE EXISTING MASTIC, ADHESIVE, AND ANY FASTENERS TO PROPERLY PREPARE THE EXISTING PLASTER TO RECEIVE NEW PLASTER PATCHING AND PAINT FINISH. 7 EXISTING WOOD CAP TRIM WITH SLOPED TOP AND SLOPED WOOD WINDOW SILL TO REMAIN. (RE-ANCHOR AS REQUIRED AFTER REMOVAL OF THE EXISTING WOOD WAINSCOT BELOW.) REFER TO DETAILS 1/A401 AND 2/A401. 8 REMOVE THE EXISTING WOOD WAINSCOT IN ITS ENTIRETY, INCLUDING ALL ASSOCIATED FURRING AND FASTENERS. REFER TO DETAILS 1/A401 AND 2/A401. 9 AT THE WALL AREA IMMEDIATELY BEHIND THE EXISTING WOOD WAINSCOT TO BE REMOVED, THE PLASTER SUBCONTRACTOR IS TO COMPLETELY REMOVE THE EXISTING PLASTER IN ITS ENTIRETY. CUT THE EXISTING PLASTER AS REQUIRED SO AS NOT TO DISTURB AND LOOSEN THE EXISTING WALL PLASTER ABOVE TO REMAIN. DO NOT GOUGE THE BRICK AND MORTAR JOINTS. REFER TO DETAILS 1/A401 AND 2/A401. LEAVE THE EXISTING BRICK WALL SURFACE FREE OF PLASTER AND ASSOCIATED DEBRIS. BRUSH AND VACUUM THE BRICK SURFACE WHEN COMPLETE. 7 16 2 EXISTING PLASTER ARCHWAY TO REMAIN. PROTECT FROM DAMAGE. REMOVE EXISTING WALL CONSTRUCTION. REFER TO STRUCTURAL FOR NEW BEAM / LINTEL ABOVE. 8 8 9 9 6 1 5 6 11 6 3 CLEANLY CUT THE EXISTING WOOD WAINSCOT AND WOOD CAP TRIM AS REQUIRED TO MEET THE FINISH FACE OF THE NEW WALL CONSTRUCTION. EXISTING CARPET TO REMAIN. EXISTING WOOD WAINSCOT TO REMAIN. 1 A401 ORGAN AMBO 12 4 1 4 A401 10 REMOVE THE EXISTING WOOD DOOR AND DOOR FRAME IN THEIR ENTIRETY, INCLUDING ANY WOOD OR METAL THRESHOLD AND ANY WOOD BLOCKING. PREPARE WALL OPENING TO RECEIVE NEW CONSTRUCTION AS DEFINED. EXISTING RISER. 3 11 REMOVE THE EXISTING WOOD ALTAR CONSTRUCTION IN ITS ENTIRETY. 12 REMOVE THE EXISTING WALL CONSTRUCTION. NOTE THAT THE EXISTING ARCHED PLASTER OPENING (VISIBLE WITHIN THE EXISTING SHRINE) IS TO REMAIN AND BE PROTECTED FROM DAMAGE. EXISTING WOOD WAINSCOT TO REMAIN. SANCTUARY 3 A104 NAVE 1 VESTIBULE 100 EXISTING CERAMIC TILE THROUGHOUT VESTIBULE 100 TO REMAIN. 4 TYPICAL OF ALL SUCH PEWS. EXISTING VINYL TILE TO BE REMOVED BY OTHERS. 4 TYPICAL OF ALL SUCH PEWS. 104 STAIR 105 1 1 EXISTING VINYL TILE TO BE REMOVED BY OTHERS. ALTAR EXISTING CARPET TO REMAIN ON TREADS AND RISERS. 4 101 EXISTING CARPET TO REMAIN. STOR. 102 EXISTING FLOORING TO REMAIN. EXISTING VINYL TILE TO BE REMOVED BY OTHERS. CONFESSIONAL EXISTING FLOORING TO REMAIN. REMOVE EXISTING WOOD STUD FRAMING FROM FACE OF EXISTING MASONRY / STONE WALL ADJACENT TO STAIRS. (THIS IS BEING DONE TO WIDEN THE CLEAR WIDTH OF THE STAIRS SO THE NEW HVAC EQUIPMENT CAN PASS.) VERIFY WITH THE ARCHITECT IN THE FIELD THAT THE EXACT WOOD STUD FRAMING IS NOT STRUCTURAL OR SUPPORTING. EXISTING VINYL TILE TO BE REMOVED BY OTHERS. EXISTING WOOD WAINSCOT AND WOOD CAP TRIM TO REMAIN. (TYPICAL AT SOUTH WALL OF NAVE.) EXISTING WOOD WAINSCOT AND WOOD CAP TRIM TO REMAIN. (TYPICAL AT SOUTH WALL OF NAVE.) 1 Demolition Plan - First Floor Scale: 1/4" = 1'-0" NORTH 2015.004 3 6 5 Demolition Plan - First Floor (REFER ALSO TO INTERIOR ELEV. 1/A401.) 19 North Alabama Street Brazil, Indiana 47834 2 A401 TYPICAL AT NORTH WALL OF NAVE. CLEANLY CUT THE EXISTING WOOD WAINSCOT AND WOOD CAP TRIM AS REQUIRED TO MEET THE FINISH FACE OF THE NEW WALL CONSTRUCTION. C. OWNER WILL PROVIDE THE TRUCK TRANSPORTATION FOR THE PEWS. OWNER WILL PROVIDE ALL DOLLIES, EQUIPMENT, AND LOGISTICS REQUIRED FOR MOVING THE PEWS. GENERAL CONTRACTOR IS TO PROVIDE DIRECTION / COORDINATION OF THE REMOVAL OF THE PEWS, LOADING OF THE TRUCK (BOTH WAYS), UNLOADING OF THE TRUCK (BOTH WAYS), AND THE MOVING OF THE PEWS BACK INTO THE CHURCH. GENERAL CONTRACTOR IS TO PROVIDE DIRECTION / COORDINATION OF THE ORGANIZATION OF THE PEWS AS THEY ARE LOADED ONTO THE TRUCK, PLACED INTO STORAGE, RE-LOADED ONTO THE TRUCK, AND PLACED BACK INTO THE CHURCH. GENERAL CONTRACTOR IS TO PROVIDE ALL LABOR AND MATERIALS REQUIRED TO RE-ANCHOR THE PEWS INTO THEIR NEW LOCATIONS AS INDICATED ON SHEET A104. THE OWNER ANTICIPATES THAT THEY CAN PROVIDE SUFFICIENT MANPOWER TO MOVE THE PEWS FROM THE CHURCH TO THE WAREHOUSE IN ONE DAY, AND THEN ONE DAY FOR THE RETURN OF THE PEWS FROM THE WAREHOUSE. Annunciation of the Blessed Virgin Mary Catholic Parish 3 A401 Revision Date EXISTING ELECTRICAL PANEL TO BE RELOCATED - REFER TO THE ELECTRICAL DRAWINGS. Produced 2 April 1, 2015 THE EXISTING VINYL FLOOR TILE IS TO BE REMOVED BY THE OWNER'S SEPARATE ASBESTOS CONTRACTOR, INCLUDING ALL EXISTING MASTIC. Project Date 1 2015.004 NOTE THAT, FOR CLARITY, SOME NEW CONSTRUCTION (NON-DEMOLITION) WORK IS DESCRIBED IN THE FOLLOWING NOTES AND INDICATED ON THE DEMOLITION PLANS. Project No. REFER ALSO TO THE DEMOLITION GENERAL NOTES ABOVE. tjw, mnp DEMOLITION PLAN KEY NOTES: These Drawings and Specifications, and all copies thereof, are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. 9. FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND RELATIONSHIPS. A102
© Copyright 2024