Testing the cleaning effect of removal debris and tissues by different files type on the cross section of the canal slices: Method: • Epoxy cast is placed around the tooth in a tube, in which assures that every slice that is to be re-mounted will return to its position.( pic. 1) • Preparation of 13mm tooth in length • Initial preparation using a manual 0.10 file ( pic. 2 ) • Slicing the tube with tooth into 6 slices of 2mm in thickness (pic.3) • Photographing all the slices (pic. 4) • Marking and numbering the slices in order and mounting them on a centralized device (pic. 5) • Prepared the teeth with 0.25 NiTi file • Disassembling and photographing • Final procedure took place using the Gentlefile • The slices are taken off the centralized device once more and are photographed • Results of the 3 teeth (see next slides ) 5 3 Centralized Split pin After cutting 2 4 6 Hand file Preparation Of the 6 Slices Before cutting Photographing 1 Centralized slot Tooth in the tube adhere with epoxy The method Cross section to 6 slice. Treated first by hand file, than a by NiTi and the last by Gentlefile. Gentlefile 0.23 Pro-Taper 0.20 Hand File 0.10 1 Coronal 2 3 Middle 4 5 Apical 6 Cross section to 6 slice. Treated first by hand file, than a by NiTi and the last by Gentlefile. Gentlefile 0.23 Pro-Taper 0.20 Hand File 0.10 1 Coronal 2 3 Middle 4 5 Apical 6 Cross section to 6 slice. Treated first by hand file, than a by NiTi and the last by Gentlefile. Gentlefile 0.23 Pro-Taper 0.20 Hand File 0.10 1 Coronal 2 3 Middle 4 5 Apical 6