ANGIOGRAPHIC CATHETERS Common Angiographic Catheter Shapes for Vessel Selection Cerebral Region

ANGIOGRAPHIC CATHETERS
A Comprehensive Offering to Meet Your Peripheral Angiography Needs
Common Angiographic Catheter Shapes for Vessel Selection
Visceral Region
Cerebral Region
Descending Aorta
1. Omni™ Flush
2. Pigtail Flush
3. Straight Flush
L and R Subclavian Artery and Vein
1. Berenstein
2. Weinberg
3. Head Hunter 1
Ascending Aorta
1. Omni™ Flush
2. Pigtail Flush
L and R Vertebral Artery and Vein
1. Berenstein
2. Weinberg
3. Head Hunter 1
4. Vertebral
Thoracic Aorta
1. Omni™ Flush
2. Pigtail Flush
3. Straight Flush
L and R Common Carotid Artery
1. Head Hunter 1
2. Sidewinder 1
3. Weinberg
4. Berenstein
5. Vertebral
6. Head Hunter 3
Abdominal Aorta
1. Omni™ Flush
2. Pigtail Flush
Hepatic Artery and Vein
1. Cobra 1, 2, or 3
2. Berenstein
3. Sos Omni® 2
4. MPA
Brachiocephalic Artery
1. Head Hunter 1
2. Sidewinder 1
3. Weinberg
4. Berenstein
Splenic Artery and Vein
1. Cobra 1, 2, or 3
2. Berenstein
3. Sos Omni® 0
4. Sidewinder 1, 2, or 3
L and R External Carotid Artery
1. Head Hunter 1
2. Sidewinder 1
3. Hockey Stick 1
4. Weinberg
5. Berenstein
6. Sidewinder 2
Gastric Artery and Vein
1. Cobra 1
2. Cobra 2
3. Sidewinder 2
4. Sos Omni® 2
5. RC1
L and R Internal Carotid Artery
1. Head Hunter 1
2. Sidewinder 1
3. Weinberg
4. Berenstein
5. Head Hunter 3
Gastroduodenal Artery and Vein
1. Cobra 2
2. Sos Omni® 0
3. Berenstein
4. Sidewinder 1
L and R Brachiocephalic Vein
1. Head Hunter 1
2. Sidewinder 1
3. Berenstein
Pancreatic Artery and Vein
1. Cobra 2
2. Sos Omni® 0
3. Berenstein
4. Sidewinder 1
L and R Internal Jugular Vein
1. Head Hunter 1
2. Sidewinder 1
3. Sidewinder 2
4. Sidewinder 3
5. Berenstein
6. Shepherd Hook 2
L and R Renal Artery
1. Sos Omni® 1
2. Sos Omni® 2
3. Cobra 1
4. MPA
L and R External Jugular Vein
1. Head Hunter 1
2. Sidewinder 1
3. Sidewinder 2
4. Sidewinder 3
5. Berenstein
Celiac Artery and Vein
1. Cobra 1
2. Berenstein
3. Sos Omni® 0
4. JB 1
Superior Mesenteric Artery and Vein
1. Cobra 1, 2, or 3
2. Berenstein
3. Sos Omni® 0
4. Sidewinder 1, 2, or 3
Inferior and Superior Vena Cava
1. Pigtail Sizing
2. Omni™ Flush
3. Rim
Uterine Artery
1. Cobra 1, 2, or 3
2. Sos Omni® 0
3. Berenstein
Peripheral Region
L and R Common Iliac Artery and Vein
1. Sos Omni® 1
2. Sos Omni® 2
3. Cobra 1
4. Berenstein
L and R Internal Iliac Artery and Vein
1. Sos Omni® 1
2. Sos Omni® 2
3. Cobra 1
4. Berenstein
L and R External Iliac Artery and Vein
1. Sos Omni® 1
2. Sos Omni® 2
3. Berenstein
L and R Common Femoral Artery and Vein
1. Sos Omni® 1
2. Sos Omni® 2
3. Cobra 1
4. Berenstein
5. MPA
L and R Deep Femoral Artery and Vein
1. Sos Omni® 1
2. Sos Omni® 2
3. Berenstein
L and R Great Saphenous Vein
1. Sos Omni® 1
2. Sos Omni® 2
3. Berenstein
L and R Popliteal Artery and Vein
1. Berenstein
2. Straight Art
L and R Anterior Tibial Artery and Vein
1. Berenstein
2. Straight Art
L and R Posterior Tibial Artery and Vein
1. Berenstein
2. Straight Art
L and R Peroneal Artery and Vein
1. Berenstein
2. Straight Art
www.angiodynamics.com
IMPORTANT RISK INFORMATION
INDICATION FOR USE: AngioDynamics Angiographic Catheters are designed for use where angiographic diagnosis is
product damage is visible. AngioDynamics Angiographic Catheters should be used only by physicians with a thorough
POTENTIAL COMPLICATIONS: The following adverse reactions have been reported and are associated with the use of
indicated. CAUTION: Federal (USA) law restricts these devices to sale by or on the order of a physician.
understanding of angiography and percutaneous interventional procedures. AngioDynamics 3 French Angiographic
angiographic catheters: Thrombus formation, emboli, arterial wall damage, plaque dislodgment, hematoma, cardiac
CONTRAINDICATIONS: Angiographic Catheters should not be used for any purpose other than those indicated in
Catheters are not intended for intracranial use. Do not insert catheters directly through synthetic vascular grafts. Insert
arrhythmias, myocardial infarction, stroke, and death.
the instructions.
through a sheath introducer. AngioDynamics Angiographic Catheters are designed for use with specific guidewire
WARNINGS AND PRECAUTIONS: This device is sterilized by ethylene oxide and is intended for single patient use only.
diameters. The recommended maximum guidewire diameter is specified on the catheter label. Optimal guidewire size
Do not reuse or resterilize. Contents sterile in unopened, undamaged package. Do not use if opened or any sign of
AngioDynamics, Soft-Vu, Accu-Vu and SOS Omni are registered trademarks of AngioDynamics. Mariner, AngiOptic and Omni are trademarks of AngioDynamics. U.S Patents: 5,584,821
© 2012 AngioDynamics, Inc. All rights reserved. MLC 219 US Rev B 12/11
and judicious use are recommended. Please see package insert for complete list of warnings and precautions.