Notice Inviting Tender for Quotation for Measuring Instruments

NATIONAL INSTITUTE OF ELECTRONICS AND INFORMATION TECHNOLOGY-GORAKHPUR
jk’Vªh; bysDVªkWfudh ,oa lwpuk izks|ksfxdh laLFkku] xksj[kiqj
A Scientific Body of Dept. of Eectronics and Information Technology,Ministry of Comm. & Information Technology, Govt. of India
(bysDVªkWfudh ,oa lwpuk izkS|ksfxdh foHkkx] lapkj ,oa lwpuk izkS|ksfxdh ea=ky;] Hkkjr ljdkj dh ,d Lok;Rr oSKkfud laLFkk)
Deoria Road, Gorakhpur-273010 (U.P.)
nsofj;k jksM ] Xkksj[kiqj ¼m0iz0½ -273010
Phone no./ Qksu ua0 0551- 2273371, Fax/ QSDl 2273873
Website: www.nielitgkp.gov.in, www.eprocure.gov.in
CDS/GP/7.4.1/F08/R0
Ref. No.: NIELIT/GKP/224/ 06/15-16
Date: 12-05-2015
QkbZy la[;k.: ukbfyV /xks//224/
fnukWd:
NOTICE INVITING TENDER
(Date of opening/ [kksyus dk rkjh[k :02-06-2015 at 0400 PM)
To/ lsok esa]
C P P Portal
Dear Sir,
You are requested to quote rate (s) for the items mentioned below as per the specifications given below:
vki }kjk fuEu fooj.k ds vuqlkj fufonk vkeaf=r fd;k tkrk gS %
Name of the Item(s) Description/Specification
dz0la0
Lkkekuksa dk uke fooj.k ,oa fof”k’fV;kW
Sl.no.
Qty.
Ekk=k
Unit
bdkbZ
01
Portable Hand Held Battery :(Specification as per enclosed Annexure-1)
Capacity Tester
01.
No
02
Digital Hand Held
Insulation Meter
: (Specification as per enclosed Annexure-2)
01
No.
03
Digital Tilt Angle Guage/
Finder
Magnetic Compass
: (Specification as per enclosed Annexure-3)
01
No.
: (Specification as per enclosed Annexure-4)
01
No.
05
Earth Resistance Measuring : (Specification as per enclosed Annexure-5)
Instruments
01
No.
06
RE resistance measuremnt
01
No.
04
: (Specification as per enclosed Annexure-6)
The Terms & Conditions should be read carefully and noted in order to comply with.
ihNs nh xbZ fu;e o “krksZ dks /;kuiwoZd vuqikyu lqfuf”fpr djsa A
Yours faithfully,
Hkonh;
For NIELIT-GORAKHPUR
,u-vkbZ-bZ-,y-vkbZ-Vh- lkslk;Vh – xksj[kiqjz ds fy,
Authorised Signatory
1
GP/7.4.1/F08/R0
TERMS AND CONDITIONS (FOR LIMITED TENDER)/fu;e o “krsZ ¼lhfer fufonk ds fy,½
The quotation should be addressed to NIELIT Gorakhpur Centre.
dksVs”ku funs”kd] jk-b-lw-izkS-la- xksj[kiqj dks lEcksf/kr gksuk pkfg,A
2. The price quoted should be firm and F.O.R. NIELIT Gorakhpur Centre. Wherever possible, educational prices should be
quoted. Quantity indicated is tentative and is subject to change.dksVsM ewY; vifjorZuh; ,oa ,Q0vks0vkj0 jk’Vªh; bysDVªkWfudh ,oa lwpuk
izks|ksfxdh laLFkku xksj[kiqj dsUnz] gksuk pkfg,A tg‚a laHko gks “kS{kf.kd ewY; dksV djsaA n”kkZ;h xbZZ ek=k vkjafHkd gS vkSj de ;k vf/kd dh tk ldrh gSA
3. The quotation/offer should be submitted on or before last date of submission in the sealed envelope. The envelope should be
superscripted as as “Quotation for Measuring Instruments” and should bear the enquiry number and due date
on the top. Quotations received after the due date will not be considered.dksVs”ku vafre frfFk ds fnu ;k igys lhy ;qDr@eqgjcan
fyQkQk esa tek gksuk pkfg,AfyQkQk ds Åij “-------------------------gsrw dksVs”ku “ ,oa baDok;jh la[;k rFkk vafre frfFk Li’V :i ls vafdr gksuk pkfg,A
fu/kkZfjr frfFk ds i”pkr izkIr dksVs”ku ekU; ugha gksxkA
4. Quotations will not be accepted by Fax, Email or any such electronic data transfer form.
m)j.k@dksVs”ku QSDl] b&esy ;k vU; fdlh Hkh rjg dh bysDækfud MkVk ækalQj :Ik esa Lohdkj ugha fd;k tk,xkA
5. Customs Duty, Excise Duty, Sales Tax, C & F, Packing & Forwarding, Insurance, Transportation, Octroi, Installation,
Training, etc charges should be separately mentioned. Discount, if any, should also be mentioned. Total price of the goods
should also be mentioned.
dLVe M~;wVh@vk;kr “kqYd],Dlkbt M~;wVh@mRiknu “kqYd] lsYl VsDl@fcdzzh dj]] lh0,.M0,Q0] iSfdax vkSj QkjofMZax] ba”;ksjsUl@chek]
VªkaliksVsZ”ku@ifjogu] vkWDVªkWb] izfr’Bkiu] izf”k{k.k ,oa vU; VSDl@dj@ewY; vyx ls mYysf[kr djsaA ;fn dksbZ NwV gks rks mls Hkh mYysf[kr djsaA oLrq
dk laiw.kZ ewY; Hkh mYysf[kr djsaA
6. Octroi of Respective Municipal Corporation may either be included or may be shown as ‘at actual’.
viuk uxjikfydk dk vkWDVªkWb dj lfEefyr djsa vFkok ns; jkf”k dk mYys[k djsaA
7. Delivery period and place of delivery should be clearly mentioned. Delivery Location should be F.O.R. NIELIT, Gorakhpur
Centre.
oLrq igqapkus dh vof/k ,oa lkeku igqapkus dk LFkku Li’V :i ls mYysf[kr djsaA oLrq igqapkus dk LFkku ,Q0vks0vkj0 jk’Vªh;
bysDVªkWfudh ,oa lwpuk izks|ksfxdh laLFkku xksj[kiqj dsUn gksuk pkfg,A
8. The goods should be quoted along with a warranty period of minimum ‘One year’ from the date of successful installation.
lkjs oLrq dh okjaVh izfr’Bkiu ds fnu ls de ls de ,d lky dh gksxh tks fd dksVs”ku esa mYysf[kr gksuk pkfg,A
9. Validity of the quotation should be mentioned. Normally quotations should be valid for at least 60 days from the date of
opening of the quotation.
dksVs”ku dh oS/krk vo”; mYysf[kr gksuk pkfg,A lkekU;r;k dksVs”ku dh oS/krk dksVs”ku ds [kqyus ds fnu ls de ls de 60 fnuksa rd gksuk pkfg,A
10. The bidding firm must have a valid Sales Tax Registration Number and Permanent Account Number (PAN)
fuosfnr laLFkk @dksV djus okyh laLFkk dk oS/kkfud fcdzh dj izek.k Ik= la[;k@lsYl VsDl jftLæs”ku uacj gksuk vko”;d gSk
1.
11. Payment Terms:
Hkqxrku@vnk;xh dh “krsZa%
Payment @90 % of the invoice value to the successful bidder will be made after physical verification / installation and
commissioning of the goods at NIELIT -GORAKHPUR CENTRE. The Centre will make remaining 10% payment after
satisfactory inspection.
lQy fufonkdkj dks jk’Vªh; bysDVªkWfudh ,oa lwpuk izks|ksfxdh laLFkku] xksj[kiqj esa oLrq@oLrqvksa ds larks’ktud vkiwfrZ ,oa
izfr’Bkiu ds i”pkr fcy@bUokbl dk 90 izfr”kr Hkqxrku fd;k tk,xk rFkk “ks’k 10% dk Hkqxrku lUrks’ktud izfr’Bkiu ds i”pkr gksxk A
12. Detailed description & technical specifications of the goods quoted by you should be provided. Technical literature /
brochure should accompany the quotation.
dksVs”ku ds lkFk oLrq dk foLr`r fooj.k ,oa rduhdh fooj.k ,oa fof”k’fV;ka gksuk t:jh gSA rduhdh lkfgR;@fooj.k&iqfLrdk dksVs”ku ds lkFk lfEefyr
djsaA
13. Manufacturing license or authorized Distributor / Principal or Dealer Certificate copy should be enclosed.
mRiknu vuqefr i= vFkok vf/kd`r forjd@fizflaiy vFkok Mhyj lfVZfQdsV dh izfrfyfi layXu djsaA
14. OEM items if any, should be supplied in the original sealed packing of the original equipment manufacturer and should be
opened at NIELIT,Gorakhpur in the presence of Center’s representative only.
vks0bZ0,e0 oLrq vxj dksbZ gS] rks mldh vkiwfrZ ewy bD;wiesUV mRiknu djus okyh laLFkk ds ewy lhy;qDr iSfdax ds lkFk djsa rFkk ftls jk’Vªh;
bysDVªkWfudh ,oa lwpuk izks|ksfxdh laLFkku xksj[kiqj ds fdlh izfrfuf/k ds mifLFkfr esa gh [kksyk tkuk pkfg,A
15. It will be binding on the part of the successful bidder to supply the goods at the rates quoted, failing to which the EMD will
be forfeited and the firm will be removed from the suppliers list and no further enquiries would be sent.
lQy fufonkdkj }kjk dksV fd;k gqvk nj mlij ck/; gksxkA vlQy gksus ij mldh tekur jkf”k (bZ0,e0Mh0) tIr dj yh tk,xh rFkk vkiwfrZdrkZ dk
uke vkiwfrZdrkZ ds lwph ls gVk fn;k tk,xk ,oa vkxs mls dksbZ Hkh buDok;jh ugha Hksth tk,xhA
16. NIELIT,Gorakhpur does not bind itself to accept the lowest or any such quotation and has the right to accept or reject whole
or any part of tenders or a portion of the supply of goods without assigning any reasons. No correspondence in case of
rejected tenders will be entertained. Incomplete quotations are liable to be rejected.
jk’Vªh; bysDVªkWfudh ,oa lwpuk izks|ksfxdh laLFkku xksj[kiqj U;wure nj okys m)j.k@dksVs”ku ;k vU; fdlh m)j.k@dksVs”ku dks Lohd`r djus gsrw ck/;
ugha gS ,oa mls vf/kdkj gS fd og fdlh Hkh fufonk ;k vkiwfrZ fd, gq, oLrq@oLrqvksa dks laiw.kZ ;k vkaf”kd :i ls fcuk dkj.k crk, Lohdkj ;k fujLr
dj ldrk gSaA fujLr fufonkvksa ds laca/k esa dksbZ Hkh i=kpkj fopkj.kh; vFkok ekU; ugha gksxkA v/kwjh fufonk,a vLohd`r dj nh tk,xhaAa
17. All questions, disputes or differences arising under and out of or in connection with the contract, if concluded, shall be
referred to the sole arbitrator appointed by the Director NIELIT, Gorakhpur Centre..
bdjkjukek@dkUVªsDV ds laca/k esa lHkh iz”u]fookn ;k erfHkUurk gksus ij funs”kd] jk’Vªh; bysDVªkWfudh ,oa lwpuk izks|ksfxdh laLFkku] xksj[kiqj }kjk fu;qDr
,dy@,dek= fu.kkZ;d dks lanfHkZr dh tk,x
2
ANNEXURE - 1
Technical Secification
Specification for portable Hand Held Battery Capacity Tester
•
•
•
•
•
•
•
•
Measurement of parameter for up to 500 AH battery.
Internal impedance of (Nickel metal hydride battery (NiMH), Nickel cadmium battery
(NiCd), Lithium-ion battery (Li-ion), Alkaline battery and lead Acid battery.)
Open circuit terminal voltage 3.5 V pp max.
Continous operating time 7 hours.
Maximum input voltage 50V max.
Internal resistance measurement range 4mΩ to 40 mΩ with resolution I
Voltage measurement up to 40V with resolution 10 mv
Operating Temperature up to 400C
ANNEXURE - 2
Technical Specification
Specification for Digital Hand Held Insulation meter
1. Automatic calculation of polarization indies and dielectric absorption ratio
2. Multiple Test voltages : 50, 100, 250, 500, 1000V
3. Remote test probe
4. Insulation test range : 0.01 MΩ to 10 GΩ
5. Live circuit indicator : Inhibit test if terminal voltage is >30V
6. Auto discharge of capacitive voltage
7. Maximum Capacitive load : 1µF
8. AC/DC voltage 0.1V to 600V
Input Impedance : 3MΩ
Common mode rejection ratio > 60dB
Overload protection 600V rms or dc
9. Earth bond resistance Measurements
Range 20Ω to 20kΩ
Over load protection : 2V
Open circuit test voltage : <8V
Short circuit current : >200ma
10. Operating temperature
up to +55 °C
11. Accessories : Test Leads, Test Probes, clips etc.,
12. Safety : Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO.
61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT
IV)
13. Certification : CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard
IEC/EN 61010-1 2nd Edition.
3
ANNEXURE - 3
Technical Specification
Specification for Digital Tilt Angle Gauge / Finder
Angle Accuracy ±0.1°
Automatic
Shutoff
3 Minutes
Battery
4 AA 1.5V Batteries
Battery Life
130 Hours
Compound Cut
Input Angle
Range
0° – 180°
Height
2.4"
Leg Extension
Length
16"
Leg Extension
Range
0” — 6-3/4”
Length
17"
Leveling
Accuracy (Vial)
+/- 0.05°
Range
0° to 220°
Readout
Accuracy
+/-0.1°
Simple Miter Cut
Input Angle
0° – 220°
Range
ANNEXURE - 4
Technical Specification
Specification for Magnetic Compass
1. Tool free declination adjustment
2. On the map Meridian lines
3. Magnified read-out for 1 ‫ שׁ‬accuracy
4. Protective cover with sighting mirror
5. Field reference cards for mapping
6. 3 clinometer system
7. Map magnifier
8. 4.1”x2.5”x1”
9. 1 ‫ שׁ‬resolution
10. Scales : Feet, mile, meter
4
ANNEXURE – 5
Technical Specification
Specification for Earth Resistance Measuring Instruments
Measuring Functions : 3- pole earth gound resistance, 2 pole ac resistance of a
conductor,Interference votage.
Measuring rate
: 2 measurements/second
Battery
: one 9 V
Voltages
: Between jacks H/C2 and E/CI 250V effective voltage
maximum
Between jacks S/P2 and E/CI 250 V effective voltage
maximum
Climatic Class
: VDE/VDI 3540 RZ
Working Temperature : 100C to + 500C
Temperature coefficient:”+ 0.1% of range per degree Kelvin
Safety
: IEC/EN/61010-1,600 V CAT II, pollution degree 2
Maximum deviations:
E1 Influence factor Position
E1 Deviation influence 0%
E1 Influence factor supply Voltage
E1 Deviation influence 0%
E1 Influence factor Temperature E3
E1 Deviation influence 2.3%
E1 Influence factor Serial interference voltage (20 V)
E1 Deviation influence 0.6%
E1 Influence factor Probe-and auxiliary probe resistance
E1 Deviation influence 10%
Test Voltage
: 3.7 kV
Protection type
: IP 40;IEC/EN60529
Electromagnetic compatibility: Emission: 61326 Class B
Immunity: IEC/EN 61326 Annex C
5
ANNEXURE - 6
RE resistance measurement
Measuring method : Current-voltage measurement with improved cross-talk
attenuation, no
compensation of measuring lead resistance,
with probe (3-pole) or
without probe (2-pole), as per IEC/EN
61557-5
Open circuit voltage : 23 to 24 V ac
Short circuit current : > 50 mA ac
Measuring frequency : 128 Hz
Maximum permissible overload : 250 V effective voltage
Measuring Time : 8 second ( average from when START is pressed.
Automatice changeover of resolution:
RH
<7 k Ω
Resolution 0.01 Ω
> 750 k Ω
RH
Resolution On 1 Ω
Interference voltage dispay dc+ac
Vmax 30 V effective voltage
Common mode rejection > 80dB at 50 Hz
Ri
680 K Ω
Measuring uncertainty< 10 % for pure ac and dc signals
Measuring range
0.15 Ω to 20 Ω
200 Ω
2000 Ω
Resolution
0.01 Ω
Display range 0 to 19.99 Ω
Resolution
1Ω
Display range 20 to 199.9 Ω
Resolution
1Ω
Display range 200 to 1999 Ω
6