4600rp, 4600g/4600r, 4800i User’s Guide Commercial/Retail/Industrial Area Imager ™

4600rp, 4600g/4600r, 4800i
Commercial/Retail/Industrial Area Imager
User’s Guide
™
Disclaimer
Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice,
and the reader should in all cases consult HII to determine whether any such
changes have been made. The information in this publication does not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained
herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
This document contains proprietary information that is protected by copyright.
All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of
HII.
© 2007-2009 Honeywell International Inc. All rights reserved.
Other product names or marks mentioned in this document may be trademarks
or registered trademarks of other companies and are the property of their
respective owners.
Web Address: www.honeywell.com/aidc
Hand Held Products/Dolphin/Metrologic products have no affiliation with Honeywell branded batteries/chargers, which are exclusively distributed by Global
Technology Systems pursuant to a license agreement.
Product Agency Compliance
USA
FCC Part 15 Subpart B Class A
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user
will be required to correct the interference at his own expense.
Use only shielded data cables with this system.
Caution: Any changes or modifications made to this equipment not expressly
approved by Honeywell may void the FCC authorization to operate this
equipment.
UL Statement
UL listed: UL60950-1.
Canada
Industry Canada ICES-003
This Class A digital apparatus complies with Canadian ICES-003. Operation
is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
Conformité à la règlementation canadienne
Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du
Canada. Son fonctionnement est assujetti aux conditions suivantes :
1. Cet appareil ne doit pas causer de brouillage préjudiciable.
2. Cet appareil doit pouvoir accepter tout brouillage reçu, y compris le
brouillage pouvant causer un fonctionnement indésirable.
cUL Statement
cUL listed: CSA C22.2 No.60950-1-03.
Europe
The CE marking indicates compliance to 2004/108/EC EMC Directive
with Standards EN55022 CLASS A, EN55024, EN61000-3-2,
EN61000-3-3. In addition, complies to 2006/95/EC Low Voltage
Directive, when shipped with recommended power supply.
For further information please contact:
Honeywell Imaging & Mobility Europe BV
Nijverheidsweg 9-13
5627 BT Eindhoven
The Netherlands
Honeywell International Inc. shall not be liable for use of our product with
equipment (i.e., power supplies, personal computers, etc.) that is not CE
marked and does not comply with the Low Voltage Directive.
Waste Electrical and Electronic Equipment
Information
Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN
PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste
electrical and electronic equipment (WEEE).
This product has required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health
and the environment, if not properly disposed.
In order to avoid the dissemination of those substances in our environment
and to diminish the pressure on the natural resources, we encourage you to
use the appropriate take-back systems for product disposal. Those systems
will reuse or recycle most of the materials of the product you are disposing in
a sound way.
The crossed out wheeled bin symbol informs you that the product
should not be disposed of along with municipal waste and invites you to use
the appropriate separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems,
please contact your local or regional waste administration.
You may also contact your supplier for more information on the
environmental performances of this product.
Germany
GS marked to EN60950-1:2001.
Australia/NZ
C-Tick Statement
Conforms to AS/NZS 3548.
South Korea (4600r only)
M IC
MIC Class A EMC requirements.
Mexico
Conforms to NOM-019.
International
Eye Safety Statement: LED
This device has been tested in accordance with IEC60825-1: 1993+A1+A2
LED safety, and has been certified to be within the limits of a Class 1 LED
device.
CB Scheme
Certified to IEC60950-1 (2001) First Edition.
Patents
Please refer to the product packaging for patent information.
Solids and Water Protection
The 4600g/4600r has a rating of IP41, immunity of foreign particles and dripping
water.
The 4800i has a rating of IP54, immunity of windblown dust penetration and
splashing water.
Table of Contents
Chapter 1 - Getting Started
About This Manual ...................................................... 1-1
Unpacking the Imager ................................................. 1-1
Imager Models ............................................................ 1-2
Imager Identification .................................................... 1-3
Connecting the Imager with Keyboard Wedge............ 1-4
Connecting the Imager with USB ................................ 1-5
Connecting the Imager with RS-232 Serial Port ......... 1-6
Connecting the Imager with RS-232 Wedge ............... 1-6
Programming the Interface - Plug and Play ................ 1-8
Keyboard Wedge Connection ..................................... 1-8
Laptop Direct Connect........................................... 1-8
USB Connection.......................................................... 1-9
IBM SurePos ......................................................... 1-9
USB PC or Macintosh® Keyboard ....................... 1-10
USB HID.............................................................. 1-10
USB COM Port Emulation ................................... 1-10
RS-232 Serial Port Connection ................................. 1-11
Serial Wedge Data Transmission Port ...................... 1-12
IBM 4683 Ports 5B, 9B, and 17 Connection ............. 1-12
Wand Emulation Connection..................................... 1-13
Menu Barcode Security Settings ............................... 1-14
Reading Techniques ................................................. 1-15
Chapter 2 - Terminal Interfaces
Terminal ID.................................................................. 2-1
Supported Terminals ................................................... 2-2
Keyboard Country ....................................................... 2-4
Keyboard Style ............................................................ 2-6
i
Keyboard Modifiers...................................................... 2-7
RS-232 Baud Rate............................................... 2-10
RS-232 Word Length: Data Bits, Stop Bits,
and Parity ....................................................... 2-10
RS-232 Receiver Time-Out ................................. 2-11
RS-232 Handshaking........................................... 2-12
Wand Emulation Connection ............................... 2-12
Wand Emulation ........................................................ 2-13
Data Block Size ................................................... 2-13
Delay Between Blocks ......................................... 2-14
Overall Checksum ............................................... 2-14
Wand Emulation Transmission Rate ................... 2-15
Wand Emulation Polarity ..................................... 2-15
Wand Emulation Idle............................................ 2-16
Chapter 3 - Output
Good Read Indicators.................................................. 3-1
Beeper – Good Read ............................................. 3-1
Beeper Volume – Good Read................................ 3-1
Beeper Pitch – Good Read .................................... 3-2
Beeper Duration – Good Read .............................. 3-2
LED – Good Read ................................................. 3-2
Number of Beeps – Good Read ............................ 3-2
Good Read Delay ........................................................ 3-3
User-Specified Good Read Delay................................ 3-3
Trigger Modes.............................................................. 3-4
Manual/Serial Trigger ............................................ 3-4
In-Stand Sensor Mode (4600r only)............................. 3-5
Scan Stand Mode ........................................................ 3-6
Scan Stand Symbol ............................................... 3-6
Presentation Mode....................................................... 3-7
Presentation LED Behavior after Decode .............. 3-7
Presentation Sensitivity ......................................... 3-8
Streaming Presentation™ Mode.................................. 3-8
Image Snap and Ship .................................................. 3-9
Hands Free Time-Out .................................................. 3-9
ii
Reread Delay .............................................................. 3-9
User-Specified Reread Delay.................................... 3-10
LED Power Level ...................................................... 3-10
Illumination Lights ..................................................... 3-11
Imager Time-Out ....................................................... 3-12
Aimer Delay............................................................... 3-12
User-Specified Aimer Delay ................................ 3-12
Aimer Mode ............................................................... 3-13
Centering................................................................... 3-13
Decode Search Mode ............................................... 3-15
Preferred Symbology ................................................ 3-15
Output Sequence Overview ...................................... 3-17
Output Sequence Editor ...................................... 3-20
Require Output Sequence................................... 3-20
Multiple Symbols ....................................................... 3-20
No Read .................................................................... 3-21
Print Weight............................................................... 3-21
Video Reverse........................................................... 3-22
Working Orientation .................................................. 3-22
Chapter 4 - Data Editing
Prefix/Suffix Overview ................................................. 4-1
To Add a Prefix or Suffix: ...................................... 4-2
To Clear One or All Prefixes or Suffixes:............... 4-3
To Add a Carriage Return Suffix
to all Symbologies............................................ 4-3
Prefix Selections.................................................... 4-4
Suffix Selections.................................................... 4-4
Function Code Transmit ........................................ 4-4
Intercharacter, Interfunction,
and Intermessage Delays ......................................... 4-5
Intercharacter Delay .............................................. 4-5
User Specified Intercharacter Delay...................... 4-5
Interfunction Delay ................................................ 4-6
Intermessage Delay .............................................. 4-7
iii
Chapter 5 - Data Formatting
Data Format Editor Introduction................................... 5-1
To Add a Data Format ........................................... 5-1
Other Programming Selections.............................. 5-2
Data Format Editor Commands ............................. 5-2
Data Format Editor ................................................ 5-5
Data Formatter....................................................... 5-5
Alternate Data Formats.......................................... 5-6
Chapter 6 - Secondary Interface
Secondary RS-232 Connection ................................... 6-2
Secondary Code 39 Wand Emulation.......................... 6-2
Wand Emulation Multi Block ........................................ 6-3
Delay Between Blocks ........................................... 6-3
Overall Checksum ................................................. 6-4
Wand Emulation Transmission Rate ..................... 6-4
Wand Emulation Polarity ....................................... 6-5
Wand Emulation Idle.............................................. 6-5
Data Block Size ..................................................... 6-5
Secondary Trigger Mode ............................................. 6-6
Manual/Serial Trigger ............................................ 6-6
Hands Free Time-Out .................................................. 6-7
Scan Stand Mode ........................................................ 6-8
Scan Stand Symbol ............................................... 6-8
Presentation Mode....................................................... 6-8
Chapter 7 - Symbologies
All Symbologies .......................................................... 7-2
Message Length Description ....................................... 7-2
Codabar ...................................................................... 7-3
Codabar Concatenation ......................................... 7-4
Code 39 ...................................................................... 7-5
Code 32 Pharmaceutical (PARAF) ........................ 7-7
Full ASCII............................................................... 7-7
Code 39 Code Page .............................................. 7-8
iv
Interleaved 2 of 5 ....................................................... 7-8
Code 93 .................................................................... 7-10
Straight 2 of 5 Industrial ........................................... 7-11
Straight 2 of 5 IATA (Two-Bar Start/Stop) ................ 7-12
Matrix 2 of 5 ............................................................. 7-13
Code 11 .................................................................... 7-13
Code 128 .................................................................. 7-15
ISBT 128 Concatenation ..................................... 7-15
Telepen .................................................................... 7-17
UPC-A ...................................................................... 7-18
UPC-A/EAN-13
with Extended Coupon Code ................................. 7-20
UPC-E0 .................................................................... 7-20
UPC-E1 .................................................................... 7-22
EAN/JAN-13 ............................................................. 7-23
ISBN Translate .................................................... 7-25
EAN/JAN-8 ............................................................... 7-25
MSI ........................................................................... 7-27
Plessey Code ........................................................... 7-28
GS1 DataBar Omnidirectional .................................. 7-29
GS1 DataBar Limited ............................................... 7-29
GS1 DataBar Expanded ........................................... 7-29
PosiCode .................................................................. 7-31
Trioptic Code ............................................................ 7-32
Codablock F ............................................................. 7-32
Code 16K ................................................................. 7-33
Code 49 .................................................................... 7-34
PDF417 .................................................................... 7-35
MicroPDF417 ........................................................... 7-36
GS1 Composite Codes ............................................ 7-36
UPC/EAN Version ............................................... 7-37
GS1 Emulation ......................................................... 7-37
TCIF Linked Code 39 (TLC39) ................................. 7-38
v
Postal Codes ............................................................ 7-38
Intelligent Mail Barcode ....................................... 7-38
ID-tag (UPU 4-State) ........................................... 7-39
Postnet................................................................. 7-39
Planet Code ......................................................... 7-40
British Post........................................................... 7-41
Canadian Post ..................................................... 7-41
Kix (Netherlands) Post ......................................... 7-41
Australian Post..................................................... 7-41
Japanese Post ..................................................... 7-43
China Post ........................................................... 7-43
Korea Post ........................................................... 7-44
QR Code ................................................................... 7-45
Data Matrix ............................................................... 7-46
MaxiCode .................................................................. 7-47
Aztec Code ............................................................... 7-48
Chinese Sensible (Han Xin) Code ............................ 7-49
Chapter 8 - Imaging Commands
Single-Use Basis ......................................................... 8-1
Command Syntax ........................................................ 8-1
Image Snap - IMGSNP ................................................ 8-2
IMGSNP Modifiers ................................................. 8-2
Image Ship - IMGSHP ................................................. 8-5
IMGSHP Modifiers ................................................. 8-6
Intelligent Signature Capture - IMGBOX.................... 8-14
IMGBOX Modifiers ............................................... 8-15
Chapter 9 - OCR Programming
OCR Fonts .................................................................. 9-1
OCR............................................................................. 9-1
U.S. Currency Font ..................................................... 9-2
MICR E13 B Font ........................................................ 9-2
SEMI Font ................................................................... 9-3
vi
OCR Templates .......................................................... 9-3
Creating an OCR Template................................... 9-3
Stringing Together Multiple Formats
(Creating “Or” Statements) .............................. 9-5
OCR User-Defined Variables ...................................... 9-6
Reading Multi-Row OCR ....................................... 9-7
OCR Check Character ................................................ 9-7
OCR Modulo 10 Check Character......................... 9-8
OCR Modulo 36 Check Character......................... 9-8
OCR User-Defined Check Character .......................... 9-8
Weighting Options ................................................. 9-9
OCR ISBN Application Example ............................... 9-11
OCR Template Codes ............................................... 9-13
Chapter 10 - Interface Keys
Keyboard Function Relationships ............................. 10-1
Supported Interface Keys.......................................... 10-3
Chapter 11 - Utilities
To Add a Test Code I.D. Prefix to All Symbologies... 11-1
Show Decoder Revision ............................................ 11-1
Show Engine Revision .............................................. 11-1
Show Scan Driver Revision....................................... 11-2
Show Software Revision ........................................... 11-2
Show Data Format .................................................... 11-2
Resetting the Standard Product Defaults .................. 11-2
Test Menu ................................................................. 11-3
2D PQA (Print Quality Assessment) ......................... 11-3
2D PQA Reporting............................................... 11-3
Visual Xpress Introduction ........................................ 11-4
Installing Visual Xpress from the Web................. 11-5
Quick*View ................................................................ 11-6
Installing Quick*View from the Web .................... 11-6
vii
Chapter 12 - Serial Programming Commands
Conventions............................................................... 12-1
Menu Command Syntax ............................................ 12-1
Query Commands...................................................... 12-2
Concatenation of Multiple Commands ................. 12-2
Responses ........................................................... 12-2
Examples of Query Commands ........................... 12-3
Trigger Commands .................................................... 12-4
Resetting the Standard Product Defaults .................. 12-4
Menu Commands ...................................................... 12-4
Chapter 13 - Product Specifications
4600g and 4600r........................................................ 13-1
4800i .......................................................................... 13-2
Standard Cable Pinouts............................................. 13-3
Keyboard Wedge ................................................. 13-3
Wand Emulation .................................................. 13-4
Serial Output ....................................................... 13-5
USB ..................................................................... 13-6
Chapter 14 - Maintenance
Repairs ...................................................................... 14-1
Maintenance .............................................................. 14-1
Cleaning the Device............................................. 14-1
Inspecting Cords and Connectors ....................... 14-1
Replacing the Interface Cable ............................. 14-2
Troubleshooting ......................................................... 14-4
Chapter 15 - Customer Support
Technical Assistance ................................................. 15-1
Online Technical Assistance................................ 15-1
Product Service and Repair..................................... 15-2
Online Product Service and Repair Assistance ... 15-2
Limited Warranty........................................................ 15-3
viii
Appendix A - Reference Charts
Symbology Chart......................................................... A-1
ASCII Conversion Chart (Code Page 1252) ............... A-4
Code Page Mapping of Printed Barcodes ................... A-6
Sample Symbols
OCR Programming Chart
Programming Chart
ix
x
1
Getting Started
About This Manual
This User’s Guide provides installation and programming instructions for the
4000 Series imagers. Product specifications, dimensions, warranty, and customer support information are also included.
Honeywell barcode imagers are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the barcodes in this guide.
An asterisk (*) next to an option indicates the default setting.
Unpacking the Imager
After you open the shipping carton, take the following steps:
• Check for damage during shipment. Report damage immediately to the
carrier who delivered the carton.
• Make sure the items in the carton match your order.
• Save the shipping container for later storage or shipping.
1-1
Imager Models
The chart below lists the interfaces that can be used with your imager. Refer to
Chapter 6 for programming information regarding secondary interfaces.
Models
Primary
Secondary
4600gXX03XX
4800iXX03XX
True RS-232
True RS-232
4600gXX05XX
4800iXX05XX
Keyboard wedge, TTL level
232, TTL level 232 serial
wedge, IBM 4683, wand emulation, USB keyboard, USB HID,
USB retail (IBM SurePOS),
USB COM port emulation
Wand Emulation, TTL
level 232
4600rXX05XX
4600rpXX05XX
Keyboard wedge, TTL level
232, TTL level 232 serial
wedge, IBM 4683, USB keyboard, USB HID, USB retail
(IBM SurePOS), USB COM
port emulation
TTL level 232
1-2
Imager Identification
Compliance
Label location
Item Number,
Serial Number
and Revision
Information
location
1-3
Connecting the Imager with Keyboard Wedge
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
An imager can be connected between the keyboard and PC as a “keyboard
wedge,” plugged into the serial port, or connected to a portable data terminal in
wand emulation or non decoded output mode. The following is an example of a
keyboard wedge connection:
1. Turn off power to the terminal/computer.
2. Disconnect the keyboard cable from the back of the terminal/computer.
3. Connect the appropriate interface cable to the imager and to the terminal/
computer.
4. Turn the terminal/computer power back on. The imager beeps.
5. Program the imager for a keyboard wedge interface using the Plug and Play
barcodes beginning on page 1-8.
6. Verify the imager operation by scanning a barcode from the Sample
Symbols in the back of this manual. The imager beeps once.
Your imager is factory programmed for a keyboard wedge interface to an IBM
PC AT with a USA keyboard. If this is your interface and you do not need to
modify the settings, skip to Chapter 3 - Output.
1-4
Connecting the Imager with USB
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
An imager can be connected to the USB port of a computer.
1. Connect the appropriate interface cable to the imager first, then to the computer.
2. Program the imager for a USB interface using the Plug and Play barcodes
beginning on page 1-9.
3. The imager beeps.
4. Verify the imager operation by scanning a barcode from the Sample
Symbols in the back of this manual.
For additional USB programming and technical information, refer to “USB Application Note,” available at www.honeywell.com/aidc.
1-5
Connecting the Imager with RS-232 Serial Port
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
1. Turn off power to the terminal/computer.
2. Connect the appropriate interface cable to the imager.
Note: For the imager to work properly, you must have the correct cable for your
type of terminal/computer.
3. Plug the serial connector into the serial port on your computer. Tighten the
two screws to secure the connector to the port.
4. Plug the power supply into the cable.
5. Once the imager has been fully connected, power up the computer.
6. Program the imager for an RS-232 Serial Port interface using the Plug and
Play barcode on page 1-11.
Connecting the Imager with RS-232 Wedge
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
Your imager uses True and TTL signal levels to wedge into an RS-232 serial
network. Use only serial wedge cables to prevent damage to the imager. Refer
to RS-232 Baud Rate on page 2-10 to set the baud rate and communications
protocol.
1-6
1. Turn off power to the computer.
2. Disconnect the existing serial cable from the computer.
3. Connect the appropriate interface cable to the imager.
Note: For the imager to work properly, you must have the correct cable for your
type of computer.
Host
Terminal
4. Plug the serial connector into the serial port on your computer. Tighten the
two screws to secure the connector to the port.
5. Plug the other serial connector into the host connection and tighten the two
screws.
6. Plug the power pack cable into the receptor on the imager cable.
7. Plug the power pack into a power source.
8. Once the imager has been fully connected, power up the computer.
9. To set up the serial wedge terminal ID, use the serial terminal ID 050 and
follow the instructions on page 2-1.
10. Program the port for data transmission using the barcodes on page 1-12.
1-7
Programming the Interface - Plug and Play
Plug and Play barcodes provide instant imager set up for commonly used interfaces.
Note: After you scan one of the codes, power cycle the host terminal to have
the interface in effect.
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
Keyboard Wedge Connection
If you want your system programmed for an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard, scan the barcode below. Keyboard wedge is the default interface.
IBM PC AT and Compatibles
with CR suffix
Laptop Direct Connect
For most laptops, scanning the Laptop Direct Connect barcode allows operation of the imager in parallel with the integral keyboard. The following Laptop
Direct Connect barcode also programs a carriage return (CR) suffix, and turns
on Emulate External Keyboard (page 2-7).
Laptop Direct Connect
with CR suffix
1-8
USB Connection
IBM SurePos
Scan one of the following “Plug and Play” codes to program the imager for IBM
SurePos (USB handheld imager) or IBM SurePos (USB Tabletop imager).
Note: After scanning one of these codes, you must power cycle the cash
register.
IBM SurePos
(USB Handheld Imager)
Interface
IBM SurePos
(USB Tabletop Imager)
Interface
Each barcode above also programs the following suffixes for each symbology:
Symbology
EAN-8
EAN-13
UPC-A
UPC-E
Code 39
Interleaved 2 of 5
Code 128
Suffix
0C
16
0D
0A
00 0A 0B
00 0D 0B
00 18 0B
1-9
USB PC or Macintosh® Keyboard
Scan one of the following codes to program the imager for USB PC Keyboard or
USB Macintosh Keyboard. Scanning these codes adds a CR and selects the
terminal ID (USB PC Keyboard - 124, USB Macintosh Keyboard - 125).
USB Keyboard (PC)
USB Keyboard (Mac)
USB Japanese Keyboard (PC)
USB HID
Scan the following code to program the imager for USB HID barcode imagers.
Scanning this code changes the terminal ID to 131.
USB HID Barcode Imager
USB COM Port Emulation
Scan the following code to program the imager to emulate a regular RS-232based COM port. If you are using a Microsoft® Windows® PC, you will need to
download a driver from the Honeywell website (www.honeywell.com/aidc). The
driver will use the next available COM port number. Apple® Macintosh computers recognize the imager as a USB CDC class device and automatically use a
class driver. Scanning the code below changes the terminal ID to 130.
USB COM Port Emulation
Note: No extra configuration (e.g., baud rate) is necessary.
1 - 10
CTS/RTS Emulation
On
* Off
ACK/NAK Mode
On
* Off
RS-232 Serial Port Connection
All communication parameters between the imager and terminal must match for
correct data transfer through the serial port using RS-232 protocol. Scanning
the RS-232 interface barcode programs the imager for an RS-232 interface at
38,400 baud, parity–none, 8 data bits, 1 stop bit, and adds a suffix of a CR LF.
RS-232 Interface
1 - 11
Serial Wedge Data Transmission Port
Using the following barcodes, set the port to which you want the scanned data
to transmit. Port 1 corresponds to P1 on the output cable and Port 2 corresponds to P2 on the output cable. Choosing Both sends scanned data to P1
and P2. Default = P1.
* P1
P2
Both P1 and P2
IBM 4683 Ports 5B, 9B, and 17 Connection
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
Scan one of the following “Plug and Play” codes to program the imager for IBM
4683 Port 5B, 9B, or 17.
Note: After scanning one of these codes, you must power cycle the cash
register.
IBM 4683 Port 5B Interface
IBM 4683 Port 9B
HHBCR-1 Interface
IBM 4683 Port 17 Interface
1 - 12
Each of the previous barcodes also programs the following suffixes for each
symbology:
Symbology
EAN-8
EAN-13
UPC-A
UPC-E
Code 39
Interleaved 2 of 5
Code 128
Suffix
0C
16
0D
0A
00 0A 0B
00 0D 0B
00 0A 0B
.
IBM 4683 Port 9B HHBCR-2 Interface
The IBM 4683 Port 9B HHBCR-2 Interface barcode also programs the following
suffixes for each symbology:
Symbology
EAN-8
EAN-13
UPC-A
UPC-E
Code 39
Interleaved 2 of 5
Code 128
Suffix
0C
16
0D
0A
00 0A 0B
00 0D 0B
00 18 0B
Wand Emulation Connection
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
In Wand Emulation mode, the imager decodes the barcode then sends data in
the same format as a wand imager. The Code 39 Format converts all symbologies to Code 39.
The Same Code Format transmits UPC, EAN, Code 128, Codabar, and Interleaved 2 of 5 without any changes, but converts all other symbologies to Code
39. 2D symbologies are converted to Code 128.
The Wand Emulation Plug & Play (Code 39 Format) barcode below sets the
terminal ID to 61. The Wand Emulation Plug & Play Same Code barcode
sets the terminal ID to 64. These barcodes also set the Transmission Rate to
1 - 13
25 inches per second, Output Polarity to black high, and Idle State to high. (If
you want to change the terminal ID only, without changing any other imager settings, please refer to Wand Emulation Connection on page 2-12.)
Wand Emulation
Plug & Play
(Code 39 Format)
Wand Emulation
Plug & Play
Same Code
Menu Barcode Security Settings
Honeywell 2D imagers are programmed by scanning menu barcodes or by
sending serial commands to the imager. If you want to restrict the ability to
scan menu codes, you can use the Menu Barcode Security settings. Please
contact the nearest technical support office (see Technical Assistance on page
15-1) for further information.
1 - 14
Reading Techniques
The imager has a view finder that projects a bright red or green aiming beam
that corresponds to the imager’s horizontal field of view. The aiming beam
should be centered over the barcode, but it can be positioned in any direction
for a good read.
Linear barcode
2D Matrix symbol
The aiming beam is smaller when the imager is closer to the code and larger
when it is farther from the code. Symbologies with smaller bars or elements (mil
size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. To read single or multiple
symbols (on a page or on an object), hold the imager at an appropriate distance
from the target, pull the trigger, and center the aiming beam on the symbol. If
the code being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the code +5° to prevent unwanted reflection.
1 - 15
1 - 16
2
Terminal Interfaces
Terminal ID
If your interface is not covered by a Plug and Play barcode from Chapter 1, then
refer to Supported Terminals on page 2-2 through page 2-3, and locate the Terminal ID number for your PC. Scan the Terminal ID barcode below, then scan
the numeric barcode(s) from the Programming Chart inside the back cover of
this manual to program the imager for your terminal ID. Scan Save to save your
selection.
For example, an IBM AT terminal has a Terminal ID of 003. You would scan the
Terminal ID barcode, then 0, 0, 3 from the Programming Chart inside the back
cover of this manual, then Save. If you make an error while scanning the digits
(before scanning Save), scan the Discard code on the Programming Chart,
scan the Terminal ID barcode, scan the digits, and the Save code again.
Terminal ID
Save
Note: After scanning one of these codes, you must power cycle your computer.
2-1
Supported Terminals
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
Terminal
Model(s)
DDC
DDC
DEC
DEC
3496, 3497, 122 key
3496, 3497, 102 key
VT510, 520, 525 (PC style)
VT510, 520, 525 (DEC style
LK411)
200, 400
PC, AT
Esprit
Heath Zenith
Heath Zenith
HP
HP
IBM
IBM
IBM
IBM 102 key
IBM 122 key
IBM 122 key
IBM 122 key
IBM 122 key
IBM DOS/V 106 key
IBM SurePOS
IBM SurePOS
IBM Thinkpad
IBM Thinkpad
IBM Thinkpad
I/O 122 key
ITT
Lee Data
NEC
Olivetti
Olivetti
RS-232 True
RS-232 TTL
2-2
Vectra
Vectra
XT
PS/2 25, 30, 77DX2
AT, PS/2 30–286, 50, 55SX, 60,
70, 70–061, 70–121, 80
3151, 3161, 3162, 3163, 3191,
3192, 3194, 3196, 3197, 3471,
3472, 3476, 3477
3191, 3192, 3471, 3472
3196, 3197, 3476, 3477, 3486,
3482, 3488
3180
3180 data entry keyboard
PC & Workstation
USB Handheld Imager
USB Tabletop Imager
360 CSE, 340, 750
365, 755CV
2676D, 2677C, 2677D
9271
IIS
98XX Series
M19, M200
M240, M250, M290, M380,
P500
Terminal
ID
005
071
084
104
005
003
090
003
023
001
002
003 *
006
007
008
024
114
102
128*
129*
097
106
003
008
007
007
103
001
003
000**
000
Supported Terminals
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
Terminal
Serial Wedge
Silicon Graphics
Telex 88 key
Telex 88 key
Telex 102 key
Telex 122 key
USB COM Port Emulation
USB Japanese Keyboard
(PC)
USB PC Keyboard
USB Mac Keyboard
USB HID POS
Wand Emulation (Code 39
Format)
Wand Emulation (Same
Code Format)
Model(s)
Indy, Indigoll
078, 078A, 79, 80, 191, 196,
1191,1192, 1471, 1472, 1476,
1477, 1483
Data Entry Keyboard
078, 078A, 79, 80, 191, 196,
1191,1192, 1471, 1472, 1476,
1477, 1483
078, 078A, 79, 80, 191, 196,
1191,1192, 1471, 1472, 1476,
1477, 1482, 1483
Terminal
ID
050
005
025
112
045
046
130
134
124*
125*
131*
061
064
* Default for 4600g/4600r/4600rp/4800iXX 05XX models. It is best to use the Plug and
Play barcodes, beginning on page 1-9, to program these interfaces, rather than scanning the terminal ID listed in this table.
** Default for 4600g/4800iXX 03XX models
2-3
Keyboard Country
Scan the appropriate country code below to program the keyboard for your
country. As a general rule, the following characters are supported, but need
special care for countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~
* United States
Belgium
Brazil
Canada (French)
Czech Republic
Denmark
Finland (Sweden)
France
Germany/Austria
Greece
Hungary
Israel (Hebrew)
2-4
Keyboard Country (continued)
Italy
Latin America
Netherlands (Dutch)
Norway
Poland
Portugal
Romania
Russia
SCS
Slovakia
Spain
Sweden
Switzerland (German)
2-5
Keyboard Country (continued)
Turkey F
Turkey Q
U.K.
Please refer to the Honeywell website (www.honeywell.com/aidc) for complete
keyboard country support information and applicable interfaces. If you need to
program a keyboard for a country other than one listed above, scan the Program Keyboard Country barcode below, then scan the numeric barcode(s) for
the appropriate country from the inside back cover, then the Save barcode.
Program Keyboard Country
Keyboard Style
This programs keyboard styles, such as Caps Lock and Shift Lock. Default =
Regular.
Regular is used when you normally have the Caps Lock key off.
* Regular
Caps Lock is used when you normally have the Caps Lock key on.
Caps Lock
2-6
Shift Lock is used when you normally have the Shift Lock key on (not common
to U.S. keyboards).
Shift Lock
Automatic Caps Lock is used if you change the Caps Lock key on and off.
The software tracks and reflects if you have Caps Lock on or off (AT and PS/2
only). This selection can only be used with systems that have an LED which
notes the Caps Lock status.
Automatic Caps Lock
Autocaps via NumLock barcode should be scanned in countries (e.g., Germany, France) where the Caps Lock key cannot be used to toggle Caps Lock.
The NumLock option works similarly to the regular Auotcaps, but uses the NumLock key to retrieve the current state of the Caps Lock.
Autocaps via NumLock
Emulate External Keyboard should be scanned if you do not have an external
keyboard (IBM AT or equivalent).
Emulate External Keyboard
Note: After scanning the Emulate External Keyboard barcode, you must power
cycle your computer.
Keyboard Modifiers
This modifies special keyboard features, such as CTRL+ ASCII codes and
Turbo Mode.
Control + ASCII Mode On: The imager sends key combinations for ASCII control characters for values 00-1F. Windows is the preferred mode. All keyboard
country codes are supported. DOS mode is a legacy mode, and it does not
2-7
support all keyboard country codes. New users should use the Windows mode.
Refer to Keyboard Function Relationships, page 10-1 for CTRL+ ASCII Values.
Default = Off.
Windows Mode Control + ASCII
Mode On
* Control + ASCII Mode Off
DOS Mode Control + ASCII Mode On
Turbo Mode: The imager sends characters to a terminal faster. If the terminal
drops characters, do not use Turbo Mode. Default = Off.
Turbo Mode On
* Turbo Mode Off
Numeric Keypad Mode: Sends numeric characters as if entered from a
numeric keypad. Default = Off.
Numeric Keypad Mode On
* Numeric Keypad Mode Off
2-8
Automatic Direct Connect Mode: This selection can be used if you have an
IBM AT style terminal and the system is dropping characters. Default = Off.
Automatic Direct
Connect Mode On
* Automatic Direct Connect
Mode Off
2-9
RS-232 Baud Rate
Baud Rate sends the data from the imager to the terminal at the specified rate.
The host terminal must be set for the same baud rate as the imager.
Default = 38,400.
300
600
1200
2400
4800
9600
19200
* 38400
57,600
115,200
RS-232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and
punctuation), select 7 data bits. For applications which require use of the full
ASCII set, select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
2 - 10
Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
7 Data, 2 Stop, Parity Odd
8 Data, 1 Stop, Parity Even
* 8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Odd
RS-232 Receiver Time-Out
The unit stays awake to receive data until the RS-232 Receiver Time-Out
expires. A manual or serial trigger resets the time-out. When an RS-232
receiver is sleeping, a character may be sent to wake up the receiver and reset
the time-out. A transaction on the CTS line will also wake up the receiver. The
receiver takes 300 milliseconds to completely come up. Change the RS-232
2 - 11
receiver time-out by scanning the barcode below, then scanning digits from the
inside back cover of this manual, then scanning Save. The range is 0 to 300
seconds. Default = 0 seconds (no time-out - always on).
RS-232 Receiver Time-Out
RS-232 Handshaking
RS-232 Handshaking allows control of data transmission from the Imager using
software commands from the host device. When this feature is turned Off, no
data flow control is used. When Data Flow Control is turned On, the host
device suspends transmission by sending the XOFF character (DC3, hex 13) to
the Imager. To resume transmission, the host sends the XON character (DC1,
hex 11). Data transmission continues where it left off when XOFF was sent.
Default = RTS/CTS, XON/XOFF and ACK/NAK Off.
RTS/CTS On
* RTS/CTS Off
XON/XOFF On
* XON/OFF Off
ACK/NAK On
* ACK/NAK Off
Wand Emulation Connection
The Wand Emulation Connection barcodes should be used if you want to
change the terminal ID only, without changing any other imager settings. We
recommend using Wand Emulation Plug & Play barcodes to program your
imager to emulate a wand reader. The Wand Emulation Plug & Play barcodes
change other parameters, in addition to changing the terminal ID. Please refer
to Connecting the Imager with RS-232 Wedge on page 1-6 for further information.
2 - 12
In Wand Emulation mode, the imager decodes the barcode then sends data in
the same format as a wand imager. The Code 39 Format converts all symbologies to Code 39.
The Same Code Format transmits UPC, EAN, Code 128, Codabar, and Interleaved 2 of 5 without any changes, but converts all other symbologies to Code
39. 2D symbologies are converted to Code 128.
The Code 39 Format barcode below sets the terminal ID to 61, and the Same
Code Format barcode sets the terminal ID to 64. Default = Code 39 Format.
Code 39 Format
Same Code Format
Wand Emulation
Note: See "Imager Models" on page 1-2 to determine which interfaces apply to
your imager.
Note: Changing primary wand emulation settings also changes the secondary
wand emulation settings (see Secondary Code 39 Wand Emulation on
page 6-2).
Data Block Size
This transmits the data in smaller blocks to prevent buffer overflow. Default =
40.
20
* 40
60
80
2 - 13
Delay Between Blocks
This sets the delay time between data blocks. Default = 50ms.
5ms
* 50ms
150ms
500ms
Overall Checksum
When this option is turned on, a computed check character is added at the end
of the entire message. The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00
(00H). Default = Off.
On
* Off
2 - 14
Wand Emulation Transmission Rate
The Transmission Rate is limited by the terminal’s ability to receive data without
dropping characters. Default = 25 inches/second.
10
* 25
40
80
120
150
200
Wand Emulation Polarity
The Polarity can be sent as standard with black bars high, or reversed with
white bars high. Default = Black High.
* Black High
White High
2 - 15
Wand Emulation Idle
The idle describes the state of the imager when no data is being transmitted.
When in Wand Emulation mode, you must set the imager’s idle state to match
the idle state for the device to which the imager is connected. Default = Idle
High.
* Idle High
Idle Low
2 - 16
3
Output
Good Read Indicators
Beeper – Good Read
The beeper may be programmed On or Off in response to a good read. Turning
this option off, only turns off the beeper response to a good read indication. All
error and menu beeps are still audible. Default = On.
* On
Off
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the imager emits on a
good read. Default = Medium for the 4600g/4600r/4600rp; High for the 4800i.
Low
Medium
High
Off
3-1
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the imager
emits on a good read. Default = Medium.
Low (1600 Hz)
* Medium (3250 Hz)
High (4200 Hz)
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the imager emits on a
good read. Default = Normal.
* Normal Beep
Short Beep
LED – Good Read
The LED indicator can be programmed On or Off in response to a good read.
Default = On.
* On
Off
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9. The same
number of beeps will be applied to the beeper and LED in response to a good
read. For example, if you program this option to have five beeps, there will be
five beeps and five LED flashes in response to a good read. The beeps and
3-2
LED flashes are in sync with one another. To change the number of beeps,
scan the barcodebarcode below and then scan a digit (1-9) barcode and the
Save barcode on the Programming Chart inside the back cover of this manual.
Default = One.
Number of Pulses
Good Read Delay
This sets the minimum amount of time before the imager can read another barcode. Default = No Delay.
* No Delay
Short Delay (500 ms)
Medium Delay (1,000 ms)
Long Delay (1,500 ms)
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the barcode
below, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the inside back cover, then scanning Save.
User-Specified Good Read Delay
3-3
Trigger Modes
Manual/Serial Trigger
You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 12-4). When in manual trigger
mode, the imager scans until a barcode is read, or until the trigger is released.
When in serial mode, the imager scans until a barcode has been read or until
the deactivate command is sent. The imager can also be set to turn itself off
after a specified time has elapsed (see Read Time-Out, which follows).
* Manual/Serial Trigger
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the imager’s trigger when
using serial commands to trigger the imager, or if the imager is in manual trigger
mode. Once the imager has timed out, you can activate the imager either by
pressing the trigger or using a serial trigger command. After scanning the Read
Time-Out barcode, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits from the inside back cover, then scanning Save. Default =
30,000.
Read Time-Out
Manual Trigger, Low Power
Note: Does not apply to the 4600r.
The imager powers down until the trigger is pulled. When the trigger is pulled,
the imager powers up and operates until there is no triggering for the time set
with the Low Power Time-Out barcode below. There is a delay of up to one
second in operation when the imager is first triggered, but there is no delay
when operating in low power time-out mode.
Manual Trigger, Low Power
Note: Manual Trigger, Low Power cannot be used with keyboard wedge
applications.
3-4
Low Power Time-Out Timer
Scan the Low Power Time-Out barcode to change the time-out duration (in
seconds). Then scan the time-out duration (from 0-300 seconds) from the
inside back cover, and Save. Default = 120 seconds.
If the unit remains idle during the low power time-out interval, the unit goes into
low power mode. Whenever the trigger is enabled, the low power time-out timer
is reset.
Low Power Time-Out
Note: This time-out does not begin until the imager time-out setting has expired.
In-Stand Sensor Mode (4600r only)
Note: This feature is only applicable to the flex stand with sensor
(HFSTAND5RSE) used with a 4600r, software revision 31205480-118 or
higher. To determine whether you have the correct hardware and
software, scan the Sensor On barcode. If it triple beeps, your device
does not have this capability.
This feature tells a 4600r to sense when the scanner is removed from the stand
and to begin manual triggering. When you scan Sensor On, the imager goes
into manual trigger mode when it is removed from the stand. For example, if
the 4600r is programmed for Presentation Mode (page 3-7), it would be in presentation mode whenever it is in the stand, and in manual trigger mode whenever it is removed from the stand. Default = Sensor Off.
Sensor On
* Sensor Off
3-5
Scan Stand Mode
When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan
Stand symbol (see below). When a different code is presented, the imager is
triggered to read the new code.
Note: The imager automatically adjusts the illumination LEDs to the lowest light
level possible to maintain a good lock on the Scan Stand symbol. When
a symbol is presented, the imager’s light levels adjust to the saved setting
(see LED Power Level on page 3-10). This mode requires at least 50 lux
of ambient light to operate correctly.
Scan Stand Mode
Scan Stand Symbol
When a unit is in Scan Stand mode, the LEDs shine at the Scan Stand symbol
on the base of the stand which tells it to remain idle. When the Scan Stand
symbol is covered, the imager turns the LEDs on at the configured power level
(default setting is high) and attempts to find and decode barcodes in its field of
view.
Scan Stand Symbol
3-6
Presentation Mode
This programs the imager to work in Presentation mode. The LEDs are either
off or at the lowest power for ambient conditions until a barcode is presented to
the imager. Then the LEDs turn on automatically to read the code. Presentation Mode uses ambient light to detect the barcodes. If the light level in the
room is not high enough, Presentation Mode may not work properly.
Presentation Mode
Note: The operation of advanced illumination units and non-advanced
illumination units differs slightly. When an advanced illumination unit is in
Presentation Mode and idle, the illumination LEDs go dim, but never go
out. When a non-advanced illumination unit is in Presentation Mode and
idle, the illumination LEDs go out completely.
Non-Advanced
Illumination Unit
Advanced
Illumination Unit
Presentation LED Behavior after Decode
When an imager is in presentation mode, the LEDs remain on and continue
scanning for a short time after a barcode is decoded. If you wish to turn the
LEDs off immediately after a barcode is decoded, scan the LEDs Off barcode,
below. Default = LEDs On.
* LEDs On
LEDs Off
3-7
Presentation Sensitivity
Presentation Sensitivity is a numeric range that increases or decreases the
imager's reaction time to barcode presentation. To set the sensitivity, scan the
Sensitivity barcode, then scan the degree of sensitivity (from 0-20) from the
inside back cover, and Save. 0 is the most sensitive setting, and 20 is the least
sensitive. Default = 1.
Sensitivity
Streaming Presentation™ Mode
When in Streaming Presentation mode, the imager’s aimer goes out after a
short time, but the scan illumination remains on all the time to continuously
search for barcodes.
Streaming Presentation Mode
When using Preferred Symbology (page 3-15), a lower priority symbol must be
centered on the aiming pattern to be read in Streaming Presentation Mode.
Note: Streaming Presentation Mode applies only to advanced illumination units.
Non-Advanced
Illumination Unit
3-8
Advanced
Illumination Unit
Image Snap and Ship
Image Snap and Ship tells the imager to take a picture (rather than read a barcode) when the trigger is pressed. Once the picture is snapped, it is shipped to
the host system as a jpeg file by default. To revert to barcode reading, you must
change to a different trigger mode (see Trigger Modes beginning on page 3-4).
Image Snap and Ship
Hands Free Time-Out
The Scan Stand, and Presentation, and Streaming Presentation Modes are
referred to as “hands free” modes. If the imager’s trigger is pulled when using a
hands free mode, the imager changes to manual trigger mode. You can set the
time the imager should remain in manual trigger mode by setting the Hands
Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the imager reverts to the original hands free mode.
Scan the Hands Free Time-Out barcode, then scan the time-out duration (from
0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000
ms.
Hands Free Time-Out
Reread Delay
This sets the time period before the imager can read the same barcode a second time. Setting a reread delay protects against accidental rereads of the
same barcode. Longer delays are effective in minimizing accidental rereads.
Use shorter delays in applications where repetitive barcode scanning is
required. Default = Medium.
3-9
Reread Delay only works when in Presentation Mode or Streaming
Presentation™ Mode (page 3-8).
Short (500 ms)
* Medium (750 ms)
Long (1000 ms)
Extra Long (2000 ms)
User-Specified Reread Delay
If you want to set your own length for the reread delay, scan the barcode below,
then set the delay (from 0-30,000 milliseconds) by scanning digits from the
inside back cover, then scanning Save.
User-Specified Reread Delay
LED Power Level
This selection allows you to adjust LED and aimer brightness. Off is used when
no illumination is needed. Low is used if low illumination is sufficient. High (the
default) is the brightest setting.
3 - 10
If you have an aimer delay programmed (see Aimer Delay on page 3-12), the
aimer will be at 100% power during the delay, regardless of the LED Power
Level.
Note: If you scan the Off barcode, both the aimer and illumination lights turn off,
making it impossible to scan barcodes in low light. To turn the LED Power
Level back on, move to a brightly lit area and scan either the Low or the
High barcode below.
Off
Low (50%)
* High (100%)
Illumination Lights
If you want the illumination lights on while reading a barcode, scan the Lights
On barcode, below. However, if you want to turn just the lights off, scan the
Lights Off barcode. Default = Lights On.
Note: This setting does not affect the aimer light. The aiming light can be set
using Aimer Mode (page 3-13).
* Lights On
Lights Off
3 - 11
Imager Time-Out
Imager Time-Out powers down the imager after the unit has been idle for the
specified time. To prevent the imager from powering down, set this time-out to
0. Scan Imager Time-Out, then set the time-out by scanning digits (from 0 999,999 ms) from the inside back cover, then scanning Save. Default = 60,000
ms.
Note: The default applies to firmware with a base number of 31205480. Refer
to the Show Software Revision on page 11-2 for information on
determining the firmware revision in your unit.
Imager Time-Out
Aimer Delay
The aimer delay allows a delay time for the operator to aim the imager before
the picture is taken. Use these codes to set the time between when the trigger
is pulled and when the picture is taken. During the delay time, the aiming light
will appear, but the LEDs won’t turn on until the delay time is over. Default =
200 milliseconds
400 milliseconds
* Off (no delay)
Off.
User-Specified Aimer Delay
If you want to set your own length for the duration of the delay, scan the barcode
below, then set the time-out by scanning digits (0 - 4,000 ms) from the
Programming Chart inside the back cover of this manual, then scan Save.
Delay Duration
3 - 12
Aimer Mode
This feature allows you to turn the aimer on and off. When the Interlaced barcode is scanned, the aimer is interlaced with the illumination LEDs. Default =
Interlaced.
Off
*Interlaced
Centering
Use Centering to narrow the imager’s field of view to make sure the imager
reads only those barcodes intended by the user. For instance, if multiple codes
are placed closely together, centering will insure that only the desired codes are
read. (Centering can be used in conjunction with Aimer Delay, page 3-12, for
the most error-free operation in applications where multiple codes are spaced
closely together. Using the Aimer Delay and Centering features, the imager can
emulate the operation of older systems, such as linear laser barcode imagers.)
In the example below, the gray area is the full imager field of view and the white
area is the centering window. Barcode 1 will not be read, while Barcode 2 will
be.
Barcode 1
Barcode 2
The default centering window is a 128x96 pixel area in the center of the
3 - 13
imager’s field of view. The following diagram illustrates the default top, bottom,
left, and right pixel positions, measured from the top and the left side of the
imager’s field of view, which is 640 by 480 pixels.
40%
60%
100%
0
Top
40%
Bottom
Default
Center
60%
Left
Right
100%
If a barcode is not within the predefined window, it will not be decoded or output
by the imager. If centering is turned on by scanning Centering On, the imager
only reads codes that intersect the centering window you specify using the Top,
Bottom, Left, or Right barcodes.
Scan Centering On, then scan one of the following barcodes to change the top,
bottom, left, or right of the centering window. Then scan the percent you want
to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom
and Right.
Centering On
* Centering Off
Top of Centering Window
Bottom of Centering Window
Left of Centering Window
Right of Centering Window
3 - 14
Decode Search Mode
There are three selectable decode (scanning) modes:
Full Omnidirectional - Searches for barcode features beginning at the center
of an image, and searches to the image’s limits. This mode reads all symbologies (including OCR), in any orientation. The Full Omnidirectional search is
very thorough which may slow performance time.
Note: This search mode is the default setting.
Full Omnidirectional
Quick Omnidirectional - This is an abbreviated search for barcode features
around the center region of an image. This mode quickly reads all symbologies
in any orientation. The Quick Omnidirectional mode may miss some off-center
symbols, as well as larger Data Matrix and QR Code symbols.
Quick Omnidirectional
Advanced Linear Decoding - Performs quick horizontal linear scans in a center band of the image. This mode is not omnidirectional, but does quickly read
linear and stacked barcodes. Advanced Linear Decoding cannot read 2D, OCR,
or Postal symbols.
Advanced Linear Decoding
Preferred Symbology
Note: This selection does not apply to OCR.
The imager can be programmed to specify one symbology as a higher priority
over other symbologies in situations where both barcode symbologies appear
on the same label, but the lower priority symbology cannot be disabled.
For example, you may be using the imager in a retail setting to read UPC symbols, but have occasional need to read a code on a drivers license. Since some
licenses have a Code 39 symbol as well as the PDF417 symbol, you can use
Preferred Symbology to specify that the PDF417 symbol be read instead of the
Code 39.
3 - 15
Preferred Symbology classifies each symbology as high priority, low priority,
or as an unspecified type. When a low priority symbology is presented, the
imager ignores it for a set period of time (see Preferred Symbology Time-out on
page 3-17) while it searches for the high priority symbology. If a high priority
symbology is located during this period, then that data is read immediately.
If the time-out period expires before a high priority symbology is read, the
imager will read any barcode in its view (low priority or unspecified). If there is
no barcode in the imager’s view after the time-out period expires, then no data
is reported.
Note: A low priority symbol must be centered on the aiming pattern to be read.
Scan a barcode below to enable or disable Preferred Symbology. Default =
Preferred Symbology Off.
Preferred Symbology On
* Preferred Symbology Off
High Priority Symbology
To specify the high priority symbology, scan the High Priority Symbology barcode below. On the Symbology Chart on page A-1, find the symbology you
want to set as high priority. Locate the Hex value for that symbology and scan
the 2 digit hex value from the Programming Chart (inside back cover). Scan
Save to save your selection. Default = None
High Priority Symbology
Low Priority Symbology
To specify the low priority symbology, scan the Low Priority Symbology barcode below. On the Symbology Chart on page A-1, find the symbology you
want to set as low priority. Locate the Hex value for that symbology and scan
the 2 digit hex value from the Programming Chart (inside back cover).
If you want to set additional low priority symbologies, scan FF, then scan the 2
digit hex value from the Programming Chart for the next symbology. You can
program up to 5 low priority symbologies. Scan Save to save your selection.
Default = None
Low Priority Symbology
3 - 16
Preferred Symbology Time-out
Once you have enabled Preferred Symbology and entered the high and low priority symbologies, you must set the time-out period. This is the period of time
the imager will search for a high priority barcode after a low priority barcode has
been encountered. Scan the barcode below, then set the delay (from 100-3,000
milliseconds) by scanning digits from the inside back cover, then scanning
Save. Default = 500 ms.
Preferred Symbology Time-out
Preferred Symbology Default
Scan the barcode below to set all Preferred Symbology entries to their default
values.
Preferred Symbology Default
Output Sequence Overview
Require Output Sequence
When turned off, the barcode data will be output to the host as the Imager
decodes it. When turned on, all output data must conform to an edited
sequence or the imager will not transmit the output data to the host device.
Note: This selection is unavailable when Multiple Symbols (page 3-20) is
enabled.
Output Sequence Editor
This programming selection allows you to program the imager to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the barcodes are scanned. Reading
the Default Sequence symbol programs the imager to the Universal values,
shown below. These are the defaults. Be certain you want to delete or clear all
formats before you read the Default Sequence symbol.
Note: To make Output Sequence Editor selections, you’ll need to know the code
I.D., code length, and character match(es) your application requires. Use
the Alphanumeric symbols (inside back cover) to read these options.
You must hold the trigger while reading each barcode in the sequence.
To Add an Output Sequence
1. Scan the Enter Sequence symbol (see Require Output Sequence, page 320).
2. Code I.D.
On the Symbology Chart on page A-1, find the symbology to which you want
3 - 17
to apply the output sequence format. Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart (inside back
cover).
3. Length
Specify what length (up to 9999 characters) of data output will be acceptable
for this symbology. Scan the four digit data length from the Programming
Chart. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) When calculating the length, you must count any
programmed prefixes, suffixes, or formatted characters as part of the length
(unless using 9999).
4. Character Match Sequences
On the ASCII Conversion Chart (Code Page 1252), page A-4, find the Hex
value that represents the character(s) you want to match. Use the Programming Chart to read the alphanumeric combination that represents the ASCII
characters. (99 is the Universal number, indicating all characters.)
5. End Output Sequence Editor
Scan F F to enter an Output Sequence for an additional symbology, or Save
to save your entries.
Other Programming Selections
•Discard
This exits without saving any Output Sequence changes.
Output Sequence Examples
In this example, you are scanning Code 93, Code 128, and Code 39 barcodes,
but you want the imager to output Code 39 1st, Code 128 2nd, and Code 93
3rd, as shown below.
Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
3 - 18
SEQBLK
62
9999
41
FF
6A
9999
42
FF
69
9999
43
FF
sequence editor start command
code identifier for Code 39
code length that must match for Code 39, 9999 = all lengths
start character match for Code 39, 41h = “A”
termination string for first code
code identifier for Code 128
code length that must match for Code 128, 9999 = all lengths
start character match for Code 128, 42h = “B”
termination string for second code
code identifier for Code 93
code length that must match for Code 93, 9999 = all lengths
start character match for Code 93, 43h = “C”
termination string for third code
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-18, but assume a <CR> suffix and
specific code lengths, you would use the following command line:
SEQBLK62001241FF6A001342FF69001243FF
The breakdown of the command line is shown below:
SEQBLK
62
0012
41
FF
6A
0013
42
FF
69
0012
43
FF
sequence editor start command
code identifier for Code 39
A - Code 39 sample length (11) plus CR suffix (1) = 12
start character match for Code 39, 41h = “A”
termination string for first code
code identifier for Code 128
B - Code 128 sample length (12) plus CR suffix (1) = 13
start character match for Code 128, 42h = “B”
termination string for second code
code identifier for Code 93
C - Code 93 sample length (11) plus CR suffix (1) = 12
start character match for Code 93, 43h = “C”
termination string for third code
3 - 19
Output Sequence Editor
Enter Sequence
Default Sequence
Require Output Sequence
When an output sequence is Required, all output data must conform to an
edited sequence or the imager will not transmit the output data to the host
device. When it’s On/Not Required, the imager will attempt to get the output
data to conform to an edited sequence but, if it cannot, the imager transmits all
output data to the host device as is.
When the output sequence is Off, the barcode data is output to the host as the
imager decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Required
On/Not Required
*Off
Multiple Symbols
Note: This feature does not work when the Imager is in Low Power mode.
When this programming selection is turned On, it allows you to read multiple
symbols with a single pull of the Imager’s trigger. If you press and hold the trigger, aiming the Imager at a series of symbols, it reads unique symbols once,
beeping (if turned on) for each read. The imager attempts to find and decode
3 - 20
new symbols as long as the trigger is pulled. When this programming selection
is turned Off, the Imager will only read the symbol closest to the aiming beam.
Default = Off.
On
* Off
No Read
With No Read turned On, the Imager notifies you if a code cannot be read. If
using a Quick*View Scan Data Window, an “NR” appears when a code cannot
be read. If No Read is turned Off, the “NR” will not appear. Default = Off.
On
* Off
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,”
you can edit the output message using the Data Formatter (page 5-5). The hex
code for the No Read symbol is 9C.
Print Weight
Print Weight is used to adjust the way the imager reads Matrix symbols. If an
imager will be seeing consistently heavily printed matrix symbols, then a print
weight of 6 may improve the reading performance. For consistently light printing, a print weight of 2 may help. After scanning the Set Print Weight barcode,
set the print weight (from 1-7) by scanning digits from the inside back cover,
then scanning Save. Default = 4.
Set Print Weight
* Default
3 - 21
Video Reverse
Video Reverse is used to allow the imager to read barcodes that are inverted.
The Off barcode below is an example of this type of barcode. If additional
menuing is required, Video Reverse must be disabled to read the menu barcodes and then re-enabled after menuing is completed. Default = Off.
Note: Images downloaded from the unit will not be reversed. This is a setting
for decoding only.
On
* Off
Working Orientation
Some barcodes are direction-sensitive. For example, KIX codes and OCR can
misread when scanned sideways or upside down. Use the working orientation
settings if your direction-sensitive codes will not usually be presented upright to
the imager. Default = Upright.
Upright:
Rotate Code Clockwise 90°:
Upside Down:
Rotate Code
Counterclockwise 90°:
3 - 22
* Upright
Rotate Code Clockwise 90°
(Rotate Imager
Counterclockwise)
Upside Down
Rotate Code
Counterclockwise 90°
(Rotate Imager Clockwise)
3 - 23
3 - 24
4
Data Editing
Prefix/Suffix Overview
When a barcode is scanned, additional information is sent to the host computer
along with the barcode data. This group of barcode data and additional,
user-defined data is called a “message string.” The selections in this section
are used to build the user-defined data into the message string.
Prefix and Suffix characters are data characters that can be sent before and
after scanned data. You can specify if they should be sent with all symbologies,
or only with specific symbologies. The following illustration shows the breakdown of a message string:
Prefix
1-11
alpha numeric
characters
Scanned Data
variable length
Suffix
1-11
alpha numeric
characters
Points to Keep In Mind
• It is not necessary to build a message string. The selections in this chapter
are only used if you wish to alter the default settings. Default prefix = None.
Default suffix = None.
• A prefix or suffix may be added or cleared from one symbology or all
symbologies.
• You can add any prefix or suffix from the ASCII Conversion Chart (Code Page
1252), page A-4, plus Code I.D. and AIM I.D.
• You can string together several entries for several symbologies at one time.
• Enter prefixes and suffixes in the order in which you want them to appear on
the output.
• When setting up for specific symbologies, instead of All Symbologies, the
symbology ID value counts as an added prefix or suffix character.
4-1
To Add a Prefix or Suffix:
Step 1. Scan the Add Prefix or Add Suffix symbol (page 4-4).
Step 2. Determine the 2 digit Hex value from the Symbology Chart (see page
A-1) for the symbology to which you want to apply the prefix or suffix.
For example, for Code 128, Code ID is “j” and Hex ID is “6A”.
Step 3. Scan the 2 hex digits from the Programming Chart inside the back
cover of this manual or scan 9, 9 for all symbologies.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page
1252), page A-4, for the prefix or suffix you wish to enter.
Step 5. Scan the 2 digit hex value from the Programming Chart inside the back
cover of this manual.
Step 6. Repeat Steps 4 and 5 for every prefix or suffix character.
Step 7. To add the Code I.D., scan 5, C, 8, 0.
To add AIM I.D., scan 5, C, 8, 1.
To add a backslash (\), scan 5, C, 5, C.
Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once to
create the leading backslash and then to create the backslash itself.
Step 8. Scan Save to exit and save, or scan Discard to exit without saving.
Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example: Add a Suffix to a specific symbology
To send a CR (carriage return)Suffix for UPC only:
Step 1. Scan Add Suffix.
Step 2. Determine the 2 digit hex value from the Symbology Chart (see page
A-1) for UPC.
Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this
manual.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page
1252), page A-4, for the CR (carriage return).
Step 5. Scan 0, D from the Programming Chart inside the back cover of this
manual.
Step 6. Scan Save, or scan Discard to exit without saving.
4-2
To Clear One or All Prefixes or Suffixes:
You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. When you Clear One Prefix (Suffix), the specific character you select is
deleted from the symbology you want. When you Clear All Prefixes (Suffixes),
all the prefixes or suffixes for a symbology are deleted.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2. Determine the 2 digit Hex value from the Symbology Chart (see page
A-1) for the symbology from which you want to clear the prefix or suffix.
Step 3. Scan the 2 digit hex value from the Programming Chart inside the back
cover of this manual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to all Symbologies
Scan the following barcode if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a
carriage return suffix for all symbologies.
Add CR Suffix
All Symbologies
4-3
Prefix Selections
Add Prefix
Clear One Prefix
Clear All Prefixes
Suffix Selections
Add Suffix
Clear One Suffix
Clear All Suffixes
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the imager transmits the function code to the terminal. Charts of
these function codes are provided in Supported Interface Keys starting on
page 10-3. When the imager is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted. Default = Enable.
* Enable
Disable
4-4
Intercharacter, Interfunction, and Intermessage
Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Each delay is composed of a 5 millisecond step. You can program up to 99
steps (of 5 ms each) for a range of 0-495 ms.
Intercharacter Delay
An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed
between the transmission of each character of scanned data. Scan the Intercharacter Delay barcode below, then scan the number of 5 millisecond steps
(0-99), and the Save barcode using the Programming Chart inside the back
cover of this manual.
Prefix
Scanned Data
1
2
3
4
Suffix
5
Intercharacter Delay
Intercharacter Delay
To remove this delay, scan the Intercharacter Delay barcode, then set the number of steps to 0. Scan the Save barcode using the Programming Chart inside
the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 495 milliseconds (in 5 ms steps) may be placed
after the transmission of a particular character of scanned data. Scan the
Delay Length barcode below, then scan the number of 5 millisecond steps (099), and the Save barcode using the Programming Chart inside the back cover
of this manual.
4-5
Next, scan the Character to Trigger Delay barcode, then the 2-digit hex value
for the ASCII character that will trigger the delay ASCII Conversion Chart (Code
Page 1252), page A-4.
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length barcode, and set the number of
steps to 0. Scan the Save barcode using the Programming Chart inside the
back cover of this manual.
Interfunction Delay
An interfunction delay of up to 495 milliseconds (in 5 ms steps) may be placed
between the transmission of each segment of the message string. Scan the
Interfunction Delay barcode below, then scan the number of 5 millisecond
steps (0-99), and the Save barcode using the Programming Chart inside the
back cover of this manual.
Prefix
STX
1
Scanned Data
HT
2 3 4 5
Suffix
CR
LF
Interfunction Delays
Interfunction Delay
To remove this delay, scan the Interfunction Delay barcode, then set the number of steps to 0. Scan the Save barcode using the Programming Chart inside
the back cover of this manual.
4-6
Intermessage Delay
An intermessage delay of up to 495 milliseconds (in 5 ms steps) may be placed
between each scan transmission. Scan the Intermessage Delay barcode
below, then scan the number of 5 millisecond steps (0-99), and the Save barcode using the Programming Chart inside the back cover of this manual.
1st Scan Transmission 2nd Scan Transmission
Intermessage Delay
Intermessage Delay
To remove this delay, scan the Intermessage Delay barcode, then set the number of steps to 0. Scan the Save barcode using the Programming Chart inside
the back cover of this manual.
4-7
4-8
5
Data Formatting
Data Format Editor Introduction
You may use the Data Format Editor to change the imager’s output. For example, you can use the Data Format Editor to insert characters at certain points in
barcode data as it is scanned. The selections in the following pages are used
only if you wish to alter the output. Default Data Format setting = None.
Normally, when you scan a barcode, it gets outputted automatically; however
when you do a format, you must use a “send” command (see Send Commands
on page 5-2) within the format program to output data.
Multiple formats may be programmed into the imager. They are stacked in the
order in which they are entered. However, the following list presents the order
in which formats are applied:
1.
2.
3.
4.
5.
6.
7.
8.
Specific Term ID, Actual Code ID, Actual Length
Specific Term ID, Actual Code ID, Universal Length
Specific Term ID, Universal Code ID, Actual Length
Specific Term ID, Universal Code ID, Universal Length
Universal Term ID, Actual Code ID, Actual Length
Universal Term ID, Actual Code ID, Universal Length
Universal Term ID, Universal Code ID, Actual Length
Universal Term ID, Universal Code ID, Universal Length
If you have changed data format settings, and wish to clear all formats and
return to the factory defaults, scan the Default Data Format code on page 5-5.
To Add a Data Format
Step 1. Scan the Enter Data Format symbol (page 5-5).
Step 2. Primary/Alternate Format
Determine if this will be your primary data format, or one of 3 alternate
formats. (Alternate formats allow you “single shot” capability to scan
one barcode using a different data format. After the one barcode has
been read, the imager reverts to the primary data format. See page 56.) If you are programming the primary format, scan 0 using the
Programming Chart inside the back cover of this manual. If you are
programming an alternate format, scan 1, 2, or 3, depending on the
alternate format you are programming.
Step 3. Terminal Type
Refer to Supported Terminals (page 2-2) and locate the Terminal ID
number for your PC. Scan three numeric barcodes on the inside back
cover to program the imager for your terminal ID (you must enter 3 digits). For example, scan 0 0 3 for an AT wedge.
Note: The wildcard for all terminal types is 099.
5-1
Step 4. Code I.D.
In the Symbology Chart (page A-1), find the symbology to which you
want to apply the data format. Locate the Hex value for that symbology
and scan the 2 digit hex value from the Programming Chart inside the
back cover of this manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
for this symbology. Scan the four digit data length from the
Programming Chart inside the back cover of this manual. (Note: 50
characters is entered as 0050. 9999 is a universal number, indicating
all lengths.)
Step 6. Editor Commands
Refer to Data Format Editor Commands (page 5-2). Scan the symbols
that represent the command you want to enter. 94 alphanumeric characters may be entered for each symbology data format.
Step 7. Scan Save from the Programming Chart inside the back cover of this
manual to save your entries.
Other Programming Selections
• Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
primary format, scan 0 from the Programming Chart inside the back cover of
this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending
on the alternate format you are clearing. Scan the Terminal Type and Code
I.D. (see Supported Terminals on page 2-2), and the barcode data length for
the specific data format that you want to delete. All other formats remain
unaffected.
• Save from the Programming Chart inside the back cover of this manual
This exits, saving any Data Format changes.
• Discard from the Programming Chart inside the back cover of this manual
This exits without saving any Data Format changes.
Data Format Editor Commands
Send Commands
F1 Send all characters followed by “xx” key or function code, starting from current cursor position. Syntax = F1xx (xx stands for the hex value for an
ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.)
F2 Send “nn” characters followed by “xx” key or function code, starting from
current cursor position. Syntax = F2nnxx (nn stands for the numeric value
(00-99) for the number of characters and xx stands for the hex value for an
ASCII code. See ASCII Conversion Chart (Code Page 1252), page A-4.)
F3 Send up to but not including “ss” character (Search and Send) starting from
current cursor position, leaving cursor pointing to “ss” character followed by
“xx” key or function code. Syntax = F3ssxx (ss and xx both stand for the
hex values for ASCII codes, see ASCII Conversion Chart (Code Page
1252), page A-4.)
5-2
F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor position. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see
ASCII Conversion Chart (Code Page 1252), page A-4, and nn is the
numeric value (00-99) for the number of times it should be sent.)
E9 Send all but the last “nn” characters, starting from the current cursor position. Syntax = E9nn (nn is the numeric value (00-99) for the number of
characters that will not be sent at the end of the message.)
Move Commands
F5 Move the cursor ahead “nn” characters from current cursor position.
Syntax = F5nn (nn stands for the numeric value (00-99) for the number of
characters the cursor should be moved ahead.)
F6 Move the cursor back “nn” characters from current cursor position.
Syntax = F6nn (nn stands for the numeric value (00-99) for the number of
characters the cursor should be moved back.)
F7 Move the cursor to the beginning of the data string. Syntax = F7.
EA Move the cursor to the end of the data string. Syntax = EA
Search Commands
F8 Search ahead for “xx” character from current cursor position, leaving cursor
pointing to “xx” character. Syntax = F8xx (xx stands for the hex value for
an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.)
F9 Search back for “xx” character from current cursor position, leaving cursor
pointing to “xx” character. Syntax = F9xx (xx stands for the hex value for
an ASCII code, see ASCII Conversion Chart (Code Page 1252), page A-4.)
E6 Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. Syntax = E6xx (xx
stands for the hex value for an ASCII code, see ASCII Conversion Chart
(Code Page 1252), page A-4.
E7 Search back for the first non “xx” character from the current cursor position,
leaving cursor pointing to non “xx” character. Syntax = E7xx (xx stands for
the hex value for an ASCII code, see ASCII Conversion Chart (Code Page
1252), page A-4.)
Miscellaneous Commands
FB Suppress all occurrences of up to 15 different characters, starting at the
current cursor position, as the cursor is advanced by other commands.
When the FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. Syntax = FBnnxxyy
. .zz where nn is a count of the number of suppressed characters in the list
and xxyy .. zz is the list of characters to be suppressed. (xx stands for the
hex value for an ASCII code, see ASCII Conversion Chart (Code Page
1252), page A-4.)
FC Disables suppress filter and clear all suppressed characters. Syntax = FC.
E4 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. Syntax = E4nnxx1xx2yy1yy2...zz1zz2 where nn is the total count of both
characters to be replaced plus replacement characters; xx1 defines charac-
5-3
E5
FE
EC
ED
ters to be replaced and xx2 defines replacement characters, continuing
through zz1 and zz2.
Terminates character replacement. Syntax = E5.
Compare character in current cursor position to the character “xx.” If characters are equal, increment cursor. If characters are not equal, no format
match. Syntax = FExx (xx stands for the hex value for an ASCII code, see
ASCII Conversion Chart (Code Page 1252), page A-4.)
Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted. Syntax = EC.
Check to make sure there is a non-numeric ASCII character at the current
cursor position. If character is numeric, format is aborted. Syntax = ED.
5-4
Data Format Editor
Enter Data Format
* Default Data Format
Clear One Data Format
Clear All Data Formats
Save
Discard
Data Formatter
When Data Formatter is turned off, the barcode data is output to the host as
read (including prefixes and suffixes). Choose one of the following options.
Default = Data Formatter On, but Not Required.
* Data Formatter On,
but Not Required
Data Formatter Off
When Data Formatter is required, all input data must conform to an edited format or the imager does not transmit the input data to the host device.
Data Format On, Format Required
5-5
Alternate Data Formats
Alternate formats allow you “single shot” capability to scan one barcode using a
different data format than your primary format. When data formats are programmed (see page 5-1), you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3.
An alternate format is initiated by scanning one of the 3 alternate format barcodes below. The imager will scan the next barcode, formatting the data with
the selected alternate format, then revert immediately to the primary format.
Alternate Data Format 1
Alternate Data Format 2
Alternate Data Format 3
5-6
6
Secondary Interface
By switching secondary interface cables, the imager can, for example, communicate with a portable data terminal (secondary interface) in addition to the host
terminal (primary interface). Refer to the table below for interfaces supported
by your model. Some features don’t apply if the interface is not supported by
your model.
Imager Models
Models
Primary
Secondary
4600gXX03XX
4800iXX03XX
True RS-232
True RS-232
4600gXX05XX
4800iXX05XX
Keyboard wedge, TTL level
232, TTL level 232 serial
wedge, IBM 4683, wand emulation, USB keyboard, USB HID,
USB retail (IBM SurePOS),
USB COM port emulation
Wand Emulation, TTL
level 232
4600rXX05XX
Keyboard wedge, TTL level
232, TTL level 232 serial
wedge, IBM 4683, USB keyboard, USB HID, USB retail
(IBM SurePOS), USB COM
port emulation
TTL level 232
4600rpXX05XX
Keyboard wedge, TTL level
232, TTL level 232 serial
wedge, IBM 4683, USB keyboard, USB HID, USB retail
(IBM SurePOS), USB COM
port emulation
TTL level 232
The secondary interface can be programmed at any time.
6-1
You can temporarily disable the secondary interface, but still retain the secondary interface settings in the imager’s memory by scanning the Disable barcode
below. To re-enable the secondary interface, scan the Enable barcode. Default
=Disable.
* Disable
Enable
Secondary RS-232 Connection
All communication parameters between the imager and terminal must match for
correct data transfer through the serial port using RS-232 protocol.
RS-232 programmable selections are used by both the primary and secondary
interfaces. Changing an RS-232 parameter (e.g., baud rate or parity), while in
primary or secondary mode will affect both interfaces. If you want to change the
RS-232 settings, refer to RS-232 Baud Rate, page 2-10.
RS-232 Interface
Secondary Code 39 Wand Emulation
Note: See "Imager Models" on page 6-1 to determine which interfaces apply to
your imager.
In Wand Emulation mode, the imager decodes the barcode then sends data in
the same format as a wand imager. The Code 39 Format converts all symbologies to Code 39. The Same Code Format transmits UPC, EAN, Code 128,
Codabar, and Interleaved 2 of 5 without any changes, but converts all other
symbologies to Code 39. 2D symbologies are converted to Code 128. These
codes set the transmission rate to 25 inches per second and the output polarity
to black, high. Default = Code 39 Format.
6-2
The Code 39 Format barcode below sets the terminal ID to 61, and the Same
Code Format barcode sets the terminal ID to 64.
Wand Emulation
Same Code Format
Wand Emulation
Code 39 Format
Wand Emulation Multi Block
Note: See "Imager Models" on page 6-1 to determine which interfaces apply to
your imager.
Note: Changing secondary wand emulation settings also changes the primary
wand emulation settings (see Wand Emulation on page 2-13).
Delay Between Blocks
This sets the delay time between data blocks. Default = 50ms.
5ms
* 50ms
150ms
500ms
6-3
Overall Checksum
When this option is turned on, a computed check character is added at the end
of the entire message. The check character is the character which when Exclusive-OR’d with every preceding character of the message yields a result of 0x00
(00H). Default = Off.
On
* Off
Wand Emulation Transmission Rate
The transmission rate is limited by the terminal’s ability to receive data without
dropping characters. Default = 25 inches/second.
10
* 25
40
80
120
150
200
6-4
Wand Emulation Polarity
The polarity can be sent as standard with black bars high, or reversed with white
bars high. Default = Black High.
* Black High
White High
Wand Emulation Idle
The idle describes the state of the imager when no data is being transmitted.
When in Wand Emulation mode, you must set the imager’s idle state to match
the idle state for the device to which the imager is connected. Default = Idle
High.
* Idle High
Idle Low
Data Block Size
This transmits the data in smaller blocks to prevent buffer overflow. Default =
40.
20
* 40
60
80
6-5
Secondary Trigger Mode
Manual/Serial Trigger
You can activate the imager either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 12-4). When in manual trigger
mode, the imager scans until a barcode is read, or until the trigger is released.
When in serial mode, the imager scans until a barcode has been read or until
the deactivate command is sent. The imager can also be set to turn itself off
after a specified time has elapsed (see Read Time-Out, which follows).
* Manual/Serial Trigger
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the imager’s trigger when
using serial commands to trigger the imager, or if the imager is in manual trigger
mode. Once the imager has timed out, you can activate the imager either by
pressing the trigger or using a serial trigger command. After scanning the Read
Time-Out barcode, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits from the inside back cover, then scanning Save. Default =
30,000.
Read Time-Out
Note: Programming Read Time-Out in the secondary interface also programs it
in the primary interface.
Manual Trigger, Low Power
When using Manual Trigger, Low Power, the imager powers down until the trigger is pulled. When the trigger is pulled, the imager powers up and operates
until there is no triggering for the time set with the Low Power Time-Out barcode below. There is a delay of up to one second in operation when the imager
is first triggered, but there is no delay when operating in low power time-out
mode.
Manual Trigger, Low Power
Note: Manual Trigger, Low Power cannot be used with keyboard wedge
applications.
6-6
Low Power Time-Out Timer
Scan the Low Power Time-Out barcode to change the time-out duration (in
seconds). Then scan the time-out duration (from 0-300 seconds) from the
inside back cover, and Save. Default = 120 seconds.
If the unit remains idle during the low power time-out interval, the unit goes into
low power mode. Whenever the trigger is enabled, the low power time-out timer
is reset.
Low Power Time-Out
Note: This time-out does not begin until the imager time-out setting has expired.
Programming Low Power Time-Out in the secondary interface also
programs it in the primary interface.
Hands Free Time-Out
The Automatic Trigger and Presentation Modes are referred to as “hands free”
modes. If the imager’s trigger is pulled when using a hands free mode, the
imager changes to manual trigger mode. You can set the time the imager
should remain in manual trigger mode by setting the Hands Free Time-Out.
Once the time-out value is reached, (if there have been no further trigger pulls)
the imager reverts to the original hands free mode.
Note: If you change the time-out duration for the secondary interface, the
duration of the primary interface will also be changed.
Scan the Hands Free Time-Out barcode, then scan the time-out duration (from
0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000
ms.
Hands Free Time-Out
6-7
Scan Stand Mode
When a unit is in Scan Stand mode, it remains idle as long as it sees the Scan
Stand symbol. (See Scan Stand Symbol that follows.) When a different code
is presented, the Imager is triggered to read the new code.
Note: The imager automatically adjusts the illumination LEDs to the lowest light
level possible to maintain a good lock on the Scan Stand symbol. When
a symbol is presented, the imager’s light levels adjust to the saved setting
(see LED Power Level on page 3-10).
Scan Stand Mode
Scan Stand Symbol
When a unit is in Scan Stand mode, the LEDs shine at the Scan Stand symbol
on the base of the stand which tells it to remain idle. When the Scan Stand
symbol is covered, the imager turns the LEDs on at the configured power level
(Default High) and attempts to find and decode barcodes in its field of view.
Scan Stand Symbol
Presentation Mode
This programs the imager to work in Presentation mode. The LEDs are either
off or at the lowest power for ambient conditions until a barcode is presented to
the imager. Then the LEDs turn on automatically to read the code. Presentation Mode uses ambient light to detect the barcodes. If the light level in the
room is not high enough, Presentation Mode may not work properly.
Presentation Mode
6-8
7
Symbologies
This programming section contains the following menu selections. Refer to
Chapter 12 for settings and defaults.
• All Symbologies
• ID-tag (UPU 4-State)
• Australian Post
• Intelligent Mail
Barcode
• Aztec Code
• Interleaved 2 of 5
• British Post
• Japanese Post
• Canadian Post
• Kix (Netherlands)
Post
• China Post
• Korea Post
• Chinese Sensible (Han Xin) Code
• Matrix 2 of 5
• Codabar
• MaxiCode
• Codablock F
• MicroPDF417
• Code 11
• MSI
• Code 128
• PDF417
• Code 16K
• Planet Code
• Code 39
• Plessey Code
• Code 49
• PosiCode A and B
• Code 93
• Postnet
• Data Matrix
• QR Code
• EAN/JAN-13
• Straight 2 of 5 IATA
• EAN/JAN-8
• Straight 2 of 5
Industrial
• GS1 Composite Codes
• TCIF Linked Code 39
(TLC39)
• GS1 DataBar Expanded
• Telepen
• GS1 DataBar Limited
• UPC-A/EAN-13 with
Extended Coupon
Code
• GS1 DataBar Omnidirectional
• UPC-A
7-1
All Symbologies
If you want to decode all the symbologies allowable for your imager, scan the
All Symbologies On code. If on the other hand, you want to decode only a
particular symbology, scan All Symbologies Off followed by the On symbol for
that particular symbology.
All Symbologies On
All Symbologies Off
Message Length Description
You are able to set the valid reading length of some of the barcode symbologies.
If the data length of the scanned barcode doesn’t match the valid reading length,
the imager will issue an error beep. You may wish to set the same value for
minimum and maximum length to force the imager to read fixed length barcode
data. This helps reduce the chances of a misread.
EXAMPLE: Decode only those barcodes with a count of 9-20 characters.
Min. length = 09
Max. length = 20
EXAMPLE: Decode only those barcodes with a count of 15 characters.
Min. length = 15
Max. length = 15
For a value other than the minimum and maximum message length defaults,
scan the barcodes included in the explanation of the symbology, then scan the
digit value of the message length and Save barcodes on the Programming Chart
inside the back cover of this manual. The minimum and maximum lengths and
the defaults are included with the respective symbologies.
7-2
Codabar
<Default All Codabar Settings>
Codabar
* On
Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the barcode. You
may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.
Transmit
* Don’t Transmit
Codabar Check Character
Codabar check characters are created using different “modulos.” You can program the imager to read only Codabar barcodes with Modulo 16 check characters. Default = No Check Character.
No Check Character indicates that the imager reads and transmits barcode
data with or without a check character.
When Check Character is set to Validate and Transmit, the imager will only
read Codabar barcodes printed with a check character, and will transmit this
character at the end of the scanned data.
7-3
When Check Character is set to Validate, but Don’t Transmit, the unit will only
read Codabar barcodes printed with a check character, but will not transmit the
check character with the scanned data.
* No Check Character
Validate Modulo 16, but
Don’t Transmit
Validate Modulo 16
and Transmit
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the
imager looks for a Codabar symbol having a “D” start character, adjacent to a
symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D” characters omitted.
Character Start
Stop
Start
Stop
Codabar
A12D
D34A
Select Require to prevent the imager from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols
without Stop/Start D characters.
On
* Off
Require
7-4
Codabar Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
Minimum Message Length
Maximum Message Length
Code 39
< Default All Code 39 Settings >
Code 39
* On
Off
Code 39 Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the barcode. You
may either transmit, or not transmit Start/Stop characters. Default = Don’t
Transmit.
Transmit
* Don’t Transmit
Code 39 Check Character
No Check Character indicates that the imager reads and transmits barcode
data with or without a check character.
7-5
When Check Character is set to Validate, but Don’t Transmit, the unit only
reads Code 39 barcodes printed with a check character, but will not transmit the
check character with the scanned data.
When Check Character is set to Validate and Transmit, the imager only reads
Code 39 barcodes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Character.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Code 39 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
Code 39 Append
This function allows the imager to append the data from several Code 39 barcodes together before transmitting them to the host computer. When this function is enabled, the imager stores those Code 39 barcodes that start with a
space (excluding the start and stop symbols), and does not immediately transmit the data. The imager stores the data in the order in which the barcodes are
read, deleting the first space from each. The imager transmits the appended
data when it reads a Code 39 barcode that starts with a character other than a
space. Default = Off.
On
* Off
7-6
Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian
pharmacies. This symbology is also known as PARAF.
Note: Trioptic Code (page 7-32) must be turned off while scanning Code 32
Pharmaceutical codes.
On
* Off
Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within the
barcode symbol will be interpreted as a single character. For example: $V will
be decoded as the ASCII character SYN, and /C will be decoded as the ASCII
character #. Default = Off.
NUL %U
DLE $P
SP
SPACE 0
0
@
%V
P
P
‘
%W p
+P
SOH $A
DC1 $Q
!
/A
1
1
A
A
Q
Q
a
+A
q
+Q
STX $B
DC2 $R
“
/B
2
2
B
B
R
R
b
+B
r
+R
ETX $C
DC3 $S
#
/C
3
3
C
C
S
S
c
+C
s
+S
EOT $D
DC4 $T
$
/D
4
4
D
D
T
T
d
+D
t
+T
ENQ $E
NAK $U
%
/E
5
5
E
E
U
U
e
+E
u
+U
ACK $F
SYN $V
&
/F
6
6
F
F
V
V
f
+F
v
+V
BEL $G
ETB $W
‘
/G
7
7
G
G
W
W
g
+G
w
+W
BS
$H
CAN $X
(
/H
8
8
H
H
X
X
h
+H
x
+X
HT
$I
EM
$Y
)
/I
9
9
I
I
Y
Y
i
+I
y
+Y
LF
$J
SUB $Z
*
/J
:
/Z
J
J
Z
Z
j
+J
z
+Z
VT
$K
ESC %A
+
/K
;
%F
K
K
[
%K
k
+K
{
%P
FF
$L
FS
%B
,
/L
<
%G L
L
\
%L
l
+L
|
%Q
CR
$M
GS
%C
-
-
=
%H
M
M
]
%M m
+M
}
%R
SO
$N
RS
%D
.
.
>
%I
N
N
^
%N
n
+N
~
%S
SI
$O
US
%E
/
/O
?
%J
O
O
_
%O o
+O
DEL %T
7-7
Character pairs /M and /N decode as a minus sign and period respectively.
Character pairs /P through /Y decode as 0 through 9.
Full ASCII On
* Full ASCII Off
Code 39 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the
barcode being scanned was created using a code page that is different from
the one the host program is expecting. If this is the case, scan the barcode
below, select the code page with which the barcodes were created (see Code
Page Mapping of Printed Barcodes on page A-6), and scan the value and the
Save barcode from the Programming Chart on the inside the back cover of this
manual. The data characters should then appear properly.
Code 39 Code Page
Interleaved 2 of 5
< Default All Interleaved 2 of 5 Settings >
Interleaved 2 of 5
* On
Off
Check Digit
No Check Digit indicates that the imager reads and transmits barcode data
with or without a check digit.
7-8
When Check Digit is set to Validate, but Don’t Transmit, the unit only reads
Interleaved 2 of 5 barcodes printed with a check digit, but will not transmit the
check digit with the scanned data.
When Check Digit is set to Validate and Transmit, the imager only reads Interleaved 2 of 5 barcodes printed with a check digit, and will transmit this digit at
the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate, but Don’t Transmit
Validate and Transmit
Interleaved 2 of 5 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
7-9
Code 93
< Default All Code 93 Settings >
Code 93
* On
Off
Code 93 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
Code 93 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the
barcode being scanned was created using a code page that is different from
the one the host program is expecting. If this is the case, scan the barcode
below, select the code page with which the barcodes were created (see Code
Page Mapping of Printed Barcodes on page A-6), and scan the value and the
Save barcode from the Programming Chart on the inside the back cover of this
manual. The data characters should then appear properly.
Code 93 Code Page
7 - 10
Straight 2 of 5 Industrial
<Default All Straight 2 of 5 Industrial Settings>
Straight 2 of 5 Industrial
On
* Off
Straight 2 of 5 Industrial Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 11
Straight 2 of 5 IATA (Two-Bar Start/Stop)
<Default All Straight 2 of 5 IATA Settings>
Straight 2 of 5 IATA
On
* Off
Straight 2 of 5 IATA Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 12
Matrix 2 of 5
<Default All Matrix 2 of 5 Settings>
Matrix 2 of 5
On
* Off
Matrix 2 of 5 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
Code 11
<Default All Code 11 Settings>
7 - 13
Code 11
On
* Off
Check Digits Required
This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits.
One Check Digit
* Two Check Digits
Code 11 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
7 - 14
Code 128
<Default All Code 128 Settings>
Code 128
* On
Off
ISBT 128 Concatenation
In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard
for communicating critical blood information in a uniform manner. The use of
ISBT formats requires a paid license. The ISBT 128 Application Specification
describes 1) the critical data elements for labeling blood products, 2) the current
recommendation to use Code 128 due to its high degree of security and its
space-efficient design, 3) a variation of Code 128 that supports concatenation
of neighboring symbols, and 4) the standard layout for barcodes on a blood
product label. Use the barcodes below to turn concatenation on or off. Default
=Off.
On
* Off
7 - 15
Code 128 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
Code 128 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the
barcode being scanned was created using a code page that is different from
the one the host program is expecting. If this is the case, scan the barcode
below, select the code page with which the barcodes were created (see Code
Page Mapping of Printed Barcodes on page A-6), and scan the value and the
Save barcode from the Programming Chart on the inside the back cover of this
manual. The data characters should then appear properly.
Code 128 Code Page
7 - 16
Telepen
<Default All Telepen Settings>
Telepen
On
* Off
Telepen Output
Using AIM Telepen Output, the imager reads symbols with start/stop pattern 1
and decodes them as standard full ASCII (start/stop pattern 1). When Original
Telepen Output is selected, the imager reads symbols with start/stop pattern 1
and decodes them as compressed numeric with optional full ASCII (start/stop
pattern 2). Default = AIM Telepen Output.
* AIM Telepen Output
Original Telepen Output
Telepen Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60.
Minimum Message Length
Maximum Message Length
7 - 17
UPC-A
<Default All UPC-A Settings>
UPC-A
* On
Off
UPC-A Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
* On
Off
UPC-A Number System
The numeric system digit of a UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit
it. Default = On.
* On
Off
7 - 18
UPC-A Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC-A Addenda Required
When Required is scanned, the imager will only read UPC-A barcodes that
have addenda. You must then turn on a 2 or 5 digit addenda listed on page 719. Default = Not Required.
Required
* Not Required
UPC-A Addenda Separator
When this feature is on, there is a space between the data from the barcode
and the data from the addenda. When turned off, there is no space.
Default = On.
* On
Off
7 - 19
UPC-A/EAN-13
with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended
Coupon Code. When left on the default setting (Off), the imager treats Coupon
Codes and Extended Coupon Codes as single barcodes.
If you scan the Allow Concatenation code, when the imager sees the coupon
code and the extended coupon code in a single scan, it transmits both as separate symbologies. Otherwise, it transmits the first coupon code it reads.
If you scan the Require Concatenation code, the imager must see and read
the coupon code and extended coupon code in a single read to transmit the
data. No data is output unless both codes are read.
Default = Off.
* Off
Allow Concatenation
Require Concatenation
UPC-E0
<Default All UPC-E Settings>
UPC-E0
Most UPC barcodes lead with the 0 number system. To read these codes, use
the UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1 (page 7-22). Default = On.
* UPC-E0 On
UPC-E0 Off
7 - 20
UPC-E0 Expand
UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format.
Default = Off.
On
* Off
UPC-E0 Addenda Required
When Required is scanned, the imager will only read UPC-E barcodes that
have addenda. Default = Not Required.
Required
* Not Required
UPC-E0 Addenda Separator
When this feature is On, there is a space between the data from the barcode
and the data from the addenda. When turned Off, there is no space.
Default = On.
* On
Off
UPC-E0 Check Digit
Check Digit specifies whether the check digit should be transmitted at the end of
the scanned data or not. Default = On.
* On
Off
7 - 21
UPC-E0 Number System
The numeric system digit of a UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit
it. To prevent transmission, scan Off. Default = On.
* On
Off
UPC-E0 Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC-E data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC-E1
Most UPC barcodes lead with the 0 number system. For these codes, use
UPC-E0 (page 7-20). If you need to read codes that lead with the 1 number
system, use the UPC-E1 On selection. Default = Off.
UPC-E1 On
* UPC-E1 Off
7 - 22
EAN/JAN-13
<Default All EAN/JAN Settings>
EAN/JAN-13
* On
Off
EAN/JAN-13 Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
* On
Off
7 - 23
EAN/JAN-13 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN-13 Addenda Required
When Required is scanned, the imager will only read EAN/JAN-13 barcodes
that have addenda. Default = Not Required.
Required
* Not Required
EAN/JAN-13 Addenda Separator
When this feature is On, there is a space between the data from the barcode
and the data from the addenda. When turned Off, there is no space.
Default = On.
* On
Off
Note: If you want to enable or disable EAN13 with Extended Coupon Code,
refer to UPC-A/EAN-13 with Extended Coupon Code (page 7-20).
7 - 24
ISBN Translate
When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off.
On
* Off
EAN/JAN-8
<Default All EAN/JAN-8 Settings>
EAN/JAN-8
* On
Off
EAN/JAN-8 Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
* On
Off
7 - 25
EAN/JAN-8 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
EAN/JAN-8 Addenda Required
When Required is scanned, the imager will only read EAN/JAN-8 barcodes
that have addenda. Default = Not Required.
Required
* Not Required
EAN/JAN-8 Addenda Separator
When this feature is On, there is a space between the data from the barcode
and the data from the addenda. When turned Off, there is no space.
Default = On.
* On
Off
7 - 26
MSI
<Default All MSI Settings>
MSI
On
* Off
MSI Check Character
Different types of check characters are used with MSI barcodes. You can
program the imager to read MSI barcodes with Type 10 check characters.
Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to Validate Type 10 and Transmit, the imager will
only read MSI barcodes printed with the specified type check character, and will
transmit this character at the end of the scanned data.
When Check Character is set to Validate Type 10, but Don’t Transmit, the unit
will only read MSI barcodes printed with the specified type check character, but
will not transmit the check character with the scanned data.
* Validate Type 10, but Don’t
Transmit
Validate Type 10 and Transmit
7 - 27
MSI Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
Plessey Code
<Default All Plessey Code Settings>
Plessey Code
On
* Off
Plessey Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 28
GS1 DataBar Omnidirectional
< Default All GS1 DataBar Omnidirectional Settings >
GS1 DataBar Omnidirectional
* On
Off
GS1 DataBar Limited
< Default All GS1 DataBar Limited Settings >
GS1 DataBar Limited
* On
Off
GS1 DataBar Expanded
< Default All GS1 DataBar Expanded Settings >
7 - 29
GS1 DataBar Expanded
* On
Off
GS1 DataBar Expanded Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
Minimum Message Length
Maximum Message Length
7 - 30
PosiCode
<Default All PosiCode Settings>
PosiCode A and B
* On
Off
You have to have PosiCode A and B on to read any of the PosiCode symbologies.
A and B On
(No Limited)
A and B and Limited A On
(Limited B Off)
* A and B and Limited B On
(Limited A Off)
PosiCode Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 31
Trioptic Code
Note: If you are going to scan Code 32 Pharmaceutical codes (page 7-7),
Trioptic Code must be off.
Trioptic Code is used for labeling magnetic storage media.
On
* Off
Codablock F
<Default All Codablock F Settings>
Codablock F
On
* Off
Codablock F Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
Minimum Message Length
Maximum Message Length
7 - 32
Code 16K
<Default All Code 16K Settings>
Code 16K
On
* Off
Code 16K Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160.
Minimum Message Length
Maximum Message Length
7 - 33
Code 49
<Default All Code 49 Settings>
Code 49
* On
Off
Code 49 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81.
Minimum Message Length
Maximum Message Length
7 - 34
PDF417
< Default All PDF417 Settings >
PDF417
* On
Off
PDF417 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750.
Minimum Message Length
Maximum Message Length
7 - 35
MicroPDF417
< Default All MicroPDF417 Settings >
MicroPDF417
On
* Off
MicroPDF417 Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366.
Minimum Message Length
Maximum Message Length
GS1 Composite Codes
Linear codes are combined with a unique 2D composite component to form a
new class called GS1 Composite symbology. GS1 Composite symbologies
allow for the co-existence of symbologies already in use.
On
* Off
7 - 36
UPC/EAN Version
Scan the UPC/EAN Version On barcode to decode GS1 Composite symbols
that have a UPC or EAN linear component. (This does not affect GS1 Composite symbols with a UCC/EAN-128 or GS1 linear component. If either of these
codes are the linear component, either Code 128 or the correct GS1 code must
be enabled.)
UPC/EAN Version On
* UPC/EAN Version Off
GS1 Composite Code Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435.
Minimum Message Length
Maximum Message Length
GS1 Emulation
The imager can automatically format the output from any GS1 data carrier to
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar
symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8,
ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any application that accepts GS1 data can be simplified since it only needs to recognize
one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (UPC, UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will
be the GS1-128 AIM ID, ]C1 (see Symbology Chart on page A-1).
If GS1 DataBar Emulation is scanned, all retail codes (UPC, UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will
be the GS1-DataBar AIM ID, ]em (see Symbology Chart on page A-1).
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and
UPC-E expansion is controlled by the UPC-E0 Expand (page 7-21) setting. If
the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see
Symbology Chart on page A-1).
7 - 37
Default = GS1 Emulation Off.
GS1-128 Emulation
GS1 DataBar Emulation
GS1 Code Expansion Off
* GS1 Emulation Off
TCIF Linked Code 39 (TLC39)
This code is a composite code since it has a Code 39 linear component and a
MicroPDF417 stacked code component. All barcode readers are capable of
reading the Code 39 linear component. The MicroPDF417 component can only
be decoded if TLC39 On is selected. The linear component may be decoded
as Code 39 even if TLC39 is off. Default = Off.
On
* Off
Postal Codes
Note: For best performance when reading a postal symbology, all other postal
symbologies should be turned off.
Intelligent Mail Barcode
Note: You may enable the Intelligent Mail Barcode if you have firmware with a
base number of 31205480. Refer to the Show Software Revision on
page 11-2 for information on determining the firmware revision in your
unit.
7 - 38
On
* Off
ID-tag (UPU 4-State)
Note: You may enable the ID-tag (UPU 4-State) if you have firmware with a
base number of 31205480. Refer to the Show Software Revision on
page 11-2 for information on determining the firmware revision in your
unit.
On
* Off
Postnet
On
* Off
Postnet Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
Transmit Check Digit
* Don’t Transmit Check Digit
7 - 39
Planet Code
On
* Off
Planet Code Check Digit
This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data.
Transmit Check Digit
* Don’t Transmit Check Digit
7 - 40
British Post
On
* Off
Canadian Post
On
* Off
Kix (Netherlands) Post
Note: Kix code can misread when scanned sideways or upside down. Use
Working Orientation, page 3-22, if your Kix codes will not usually be
presented upright to the imager.
On
* Off
Australian Post
On
* Off
7 - 41
Australian Post Interpretation
This option controls what interpretation is applied to customer fields in Australian 4-State symbols.
Bar Output lists the bar patterns in “0123” format.
Numeric N Table causes that field to be interpreted as numeric data using the
N Table.
Alphanumeric C Table causes the field to be interpreted as alphanumeric data
using the C Table. Refer to the Australian Post Specification Tables.
Note: You may enable the Australian Post Interpretation option if you have
firmware with a base number of 31205480. Refer to the Show Software
Revision on page 11-2 for information on determining the firmware
revision in your unit.
* Bar Output
Numeric N Table
Alphanumeric C Table
7 - 42
Japanese Post
On
* Off
China Post
<Default All China Post Settings>
China Post
On
* Off
China Post Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
7 - 43
Korea Post
<Default All Korea Post Settings>
Korea Post
On
* Off
Korea Post Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 44
QR Code
< Default All QR Code Settings >
QR Code
This selection applies to both QR Code and Micro QR Code.
* On
Off
Note: The default applies to firmware with a base number of 31205480. Refer
to the Show Software Revision on page 11-2 for information on
determining the firmware revision in your unit
QR Code Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089.
Minimum Message Length
Maximum Message Length
7 - 45
Data Matrix
< Default All Data Matrix Settings >
Data Matrix
* On
Off
Data Matrix Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116.
Minimum Message Length
Maximum Message Length
7 - 46
MaxiCode
< Default All MaxiCode Settings >
MaxiCode
* On
Off
MaxiCode Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150.
Minimum Message Length
Maximum Message Length
7 - 47
Aztec Code
< Default All Aztec Code Settings >
Aztec Code
* On
Off
Aztec Code Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832.
Minimum Message Length
Maximum Message Length
Aztec Runes
Select Enable Runes if you are scanning Aztec runes, which are the smallest
type of Aztec Code symbol with the ability to encode a very short license plate
message.
Enable Runes
* Disable Runes
7 - 48
Chinese Sensible (Han Xin) Code
< Default All Han Xin Settings >
Han Xin Code
On
* Off
Han Xin Code Message Length
Scan the barcodes below to change the message length. Refer to Message
Length Description (page 7-2) for additional information. Minimum and
Maximum lengths = 1-7833. Minimum Default = 1, Maximum Default = 7833.
Minimum Message Length
Maximum Message Length
7 - 49
7 - 50
8
Imaging Commands
The image scanner is like a digital camera in the way it captures, manipulates,
and transfers images. The following commands allow you to alter the way the
imager performs these functions.
Single-Use Basis
Imaging Commands with their modifiers send instructions to the imager on a
single-use basis, and take effect for a single image capture. Once that capture
is complete, the imager reverts to its imaging default settings. If you want to
permanently change a setting, you must use the serial default commands (see
Chapter 12). When the serial default command is used, that selection becomes
the new, permanent setting for the imager.
Command Syntax
Multiple modifiers and commands can be issued within one sequence. If additional modifiers are to be applied to the same command, just add the modifiers
to that command. For example, to add 2 modifiers to the Image Snap command, such as setting the Imaging Style to 1P and the Wait for Trigger to 1T,
you would enter IMGSNP1P1T.
Note: After processing an image capture command (IMGSNP or IMGBOX), you
must follow it with an IMGSHP command if you want to see it on your
terminal.
To add a command to a sequence, each new command is separated with a
semicolon. For example, to add the Image Ship command to the above
sequence, you would enter IMGSNP1P1T;IMGSHP.
The imaging commands are:
Image Snap - IMGSNP (page 8-2)
Image Ship - IMGSHP (page 8-5)
Intelligent Signature Capture - IMGBOX (page 8-14)
The modifiers for each of these commands follow the command description.
Note: The images included with each command description are examples only.
The results you achieve may be different from those included in this
manual. The quality of the output you receive will vary depending on
lighting, quality of the initial image/object being captured, and distance of
the imager from the image/object. To achieve a high quality image, it is
recommended that you position your imager 4-6" (122-183 cm) away
from the image/object you are capturing.
8-1
Step 1 - Take a Picture Using IMGSNP
Image Snap - IMGSNP
An image is taken whenever the hardware button is pressed, or when the Image
Snap (IMGSNP) command is processed.
The image snap command has many different modifiers that can be used to
change the look of the image in memory. Modifiers always begin with numbers
and end with a letter (case insensitive). Any number of modifiers may be
appended to the IMGSNP command. For example, you can use the following
command to snap an image, increase the gain, and have the beeper sound
once the snap is complete:
IMGSNP2G1B
IMGSNP Modifiers
P - Imaging Style
This sets the Image Snap style.
0P
Decoding Style. This processing allows a few frames to be
taken until the exposure parameters are met. The last frame is
then available for further use.
1P
Photo Style (default). This mimics a simple digital camera, and
results in a visually optimized image.
2P
Manual Style. This is an advanced style that should only be
used by an experienced user. It allows you the most freedom to
set up the imager, and has no auto-exposure.
B - Beeper
Causes a beep to sound after an image is snapped.
0B
No beep (default)
1B
Sounds a beep when the image is captured.
T - Wait for Trigger
Waits for a hardware button push before taking the image. This is only
available when using Photo Style (1P).
8-2
0T
Takes image immediately (default)
1T
Waits for a button push, then takes the image
L - LED State
Determines if the LEDs should be on or off, and when. Ambient illumination
(0L) is preferred for taking pictures of color documents, such as ID cards,
especially when the imager is in a stand. LED illumination (1L) is preferred
when the imager is handheld. LED State is not available when using Decoding
Style (0P).
0L
LEDs off (default)
1L
LEDs on
E - Exposure
Exposure is used in Manual Style only (2P), and allows you to set the exposure
time. This is similar to setting a shutter speed on a camera. The exposure
time determines how long the imager takes to record an image. On a bright
day, exposure times can be very short because plenty of light is available to
help record an image. At nighttime, exposure time can increase dramatically
due to the near absence of light. Units are 127 microseconds. (Default =
7874)
nE
Range: 1 - 7874
Example of Exposure at 7874E with
fluorescent lighting:
Example of Exposure at 100E with
fluorescent lighting:
8-3
G - Gain
Gain is used in Manual Style only (2P). Like a volume control, the gain
modifier boosts the signal and multiplies the pixel value. As you increase the
gain, the noise in an image is also amplified.
1G
No gain (default)
2G
Medium gain
4G
Heavy gain
8G
Maximum gain
Example of Gain at 1G:
Example of Gain at 4G:
Example of Gain at 8G:
W - Target White Value
Sets the target for the median grayscale value in the captured image. For
capturing close-up images of high contrast documents, a lower setting, such
as 75, is recommended. Higher settings result in longer exposure times and
brighter images, but if the setting is too high, the image may be overexposed.
Target White Value is only available when using Photo Style (1P). (Default =
125)
nW
Range: 0 - 255
Example of White
Value at 75W:
Example of White
Value at 125W:
Example of White
Value at 200W:
D - Delta for Acceptance
This sets the allowable range for the white value setting (see W - Target White
Value). Delta is only available when using Photo Style (1P). (Default = 25)
nD
Range: 0 - 255
U - Update Tries
This sets the maximum number of frames the imager should take to reach the
D - Delta for Acceptance. Update Tries is only available when using Photo
Style (1P). (Default = 6)
nU
8-4
Range: 0 - 10
% - Target Set Point Percentage
Sets the target point for the light and dark values in the captured image. A
setting of 75% means 75% of the pixels are at or below the target white value,
and 25% of the pixels are above the target white value. Altering this setting
from the default is not recommended under normal circumstances. To alter
grayscale values, W - Target White Value should be used. (Default = 50)
n%
Range: 1 - 99
Example of Target Set
Point Percentage at 97%:
Example of Target Set
Point Percentage at 50%:
Example of Target Set
Point Percentage at 40%:
Step 2 - Ship a Picture Using IMGSHP
Image Ship - IMGSHP
An image is taken whenever the button is pressed, or when the Image Snap
(IMGSNP) command is processed. The last image is always stored in memory.
You can “ship” the image by using the IMGSHP command.
The image ship commands have many different modifiers that can be used to
change the look of the image output. Modifiers affect the image that is transmitted, but do not affect the image in memory. Modifiers always begin with a number and end with a letter (case insensitive). Any number of modifiers may be
appended to the IMGSHP command. For example, you can use the following
command to snap and ship a bitmap image with gamma correction and document image filtering:
IMGSNP;IMGSHP8F75K26U
8-5
IMGSHP Modifiers
A - Infinity Filter
Enhances pictures taken from very long distances (greater than 10 feet or
3m). The Infinity Filter should not be used with IMGSHP Modifiers (page 8-6).
0A
Infinity filter off (default)
1A
Infinity filter on
Example of Infinity Filter off (0A)
from approximately 12 feet (3.66m) away:
Example of Infinity Filter on (1A)
from approximately 12 feet (3.66m) away:
C - Compensation
Flattens the image to account for variations in illumination across the image.
0C
Compensation disabled (default)
1C
Compensation enabled
Example of Compensation at 0C:
Example of Compensation at 1C:
D - Pixel Depth
Indicates the number of bits per pixel in the transmitted image (KIM or BMP
format only).
8-6
8D
8 bits per pixel, grayscale image (default)
1D
1 bit per pixel, black and white image
E - Edge Sharpen
An edge sharpen filter cleans up the edges of an image, making it look cleaner
and sharper. While edge sharpening does make the image look cleaner, it
also removes some fine detail from the original image. The strength of the
edge sharpen filter can be entered from 1 to 24. Entering a 23E gives the
sharpest edges, but also increases noise in the image.
0E
Don’t sharpen image (default)
14E
Apply edge sharpen for typical image
ne
Apply edge sharpen using strength n (n = 1-24)
Example of Edge Sharpen at 0E:
Example of Edge Sharpen at 24E:
F - File Format
Indicates the desired format for the image.
0F
KIM format
1F
TIFF binary
2F
TIFF binary group 4, compressed
3F
TIFF grayscale
4F
Uncompressed binary (upper left to lower right, 1 pixel/bit, 0
padded end of line)
5F
Uncompressed grayscale (upper left to lower right, bitmap
format)
6F
JPEG image (default)
8F
BMP format (lower right to upper left, uncompressed)
8-7
H - Histogram Stretch
Increases the contrast of the transmitted image. Not available with some
image formats.
0H
No stretch (default)
1H
Histogram stretch
Example of Histogram Stretch at 0H:
Example of Histogram Stretch at 1H:
I - Invert Image
Invert image is used to rotate the image around the X or Y axis.
1ix
Invert around the X axis (flips picture upside down)
1iy
Invert around the Y axis (flips picture left to right)
Example of image not
inverted:
8-8
Example of image
with Invert Image set to 1ix:
Example of image
with Invert Image set to 1iy:
IF- Noise Reduction
Used to reduce the salt and pepper noise in an image.
0if
No salt and pepper noise reduction (default)
1if
Salt and pepper noise reduction
Example of Noise Reduction Off (0if):
Example of Noise Reduction On (1if):
IR - Image Rotate
0ir
Image as snapped (rightside up) (default)
1ir
Rotate image 90 degrees to the right
2ir
Rotate image 180 degrees (upside down)
3ir
Rotate image 90 degrees to the left
Example of Image Rotate set to 0ir:
Example of Image Rotate set to 1ir:
Example of Image Rotate set to 2ir:
Example of Image Rotate set to 3ir:
8-9
J - JPEG Image Quality
Sets the desired quality when the JPEG image format is selected. Higher
numbers result in higher quality, but larger files. Smaller numbers result in
greater amounts of lossy compression, faster transmission times, lower
quality, but smaller files. (Default = 50)
nJ
Image is compressed as much as possible while preserving
quality factor of n (n = 0 - 100)
0J
worst quality (smallest file)
100J best quality (largest file)
K - Gamma Correction
Gamma measures the brightness of midtone values produced by the image.
You can brighten or darken an image using gamma correction. A higher
gamma correction yields an overall brighter image. The lower the setting, the
darker the image. The optimal setting for text images is 50K.
0K
Gamma correction off (default)
50K
Apply gamma correction for brightening typical document image
nK
Apply gamma correction factor n (n = 0-1,000)
Example of Gamma
Correction set to 0K:
Example of Gamma
Correction set to 50K:
Example of Gamma
Correction set to 255K:
L, R, T, B, M - Image Cropping
Note: Image Cropping should not be used with IMGSHP Modifiers (see
page 8-6).
Ships a window of the image by specifying the left, right, top, and bottom pixel
coordinates. Device columns are numbered 0 through 640, and device rows
are numbered 0 through 480.
8 - 10
nL
The left edge of the shipped image corresponds to column n of
the image in memory. Range: 000 - 640. (Default = 0)
nR
The right edge of the shipped image corresponds to column n 1 of the image in memory. Range: 000 - 640. (Default = all
columns)
nT
The top edge of the shipped image corresponds to row n of the
image in memory. Range: 000 - 480. (Default = 0)
nB
The bottom edge of the shipped image corresponds to row n - 1
of the image in memory. Range: 000 - 480. (Default = all rows)
Uncropped Image:
Example of Image Crop set to 200B:
Example of Image
Crop set to 300R:
Example of Image
Crop set to 300L:
Example of Image Crop set to 200T:
Alternately, specify the number of pixels to cut from the outside margin of the
image; thus only the center pixels are transmitted.
nM
Margin: cut n columns from the left, n + 1 columns from the right,
n rows from the top, and n + 1 rows from the bottom of the image.
Ship the remaining center pixels. Range: 0 - 238.
(Default = 0, or full image)
Example of Image
Crop set to 238M:
P - Protocol
Used for shipping an image. Protocol covers two features of the image data
being sent to the host. It addresses the protocol used to send the data
(Hmodem, which is an Xmodem 1K variant that has additional header
information), and the format of the image data that is sent.
0P
None (raw data)
2P
None (default for USB)
3P
Hmodem compressed (default for RS-232)
4P
Hmodem
8 - 11
S - Pixel Ship
Pixel Ship sizes an image in proportion to its original size. It decimates the
image by shipping only certain, regularly spaced pixels. For example, 4S
would transmit every fourth pixel from every fourth line. The smaller number
of pixels shipped, the smaller the image, however, after a certain point the
image becomes unusable.
1S
ship every pixel (default)
2S
ship every 2nd pixel, both horizontally and vertically
3S
ship every 3rd pixel, both horizontally and vertically
Example of Pixel Ship set to 1S:
Example of Pixel Ship
set to 2S:
Example of Pixel
Ship set to 3S:
U - Document Image Filter
Allows you to input parameters to sharpen the edges and smooth the area
between the edges of text in an image. This filter should be used with gamma
correction (see page 8-10), with the imager in a stand, and the image captured
using the command:
IMGSNP1P0L168W90%32D
This filter typically provides better JPEG compression than the standard E Edge Sharpen command (see page 8-14). This filter also works well when
shipping pure black and white images (1 bit per pixel). The optimal setting is
26U.
8 - 12
0U
Document image filter off (default)
26U
Apply document image filter for typical document image
nU
Apply document image filter using grayscale threshold n. Use
lower numbers when the image contrast is lower. 1U will have a
similar effect to setting E - Edge Sharpen (page 8-7) to 22e.
Range: 0-255.
Example of Document Image
Filter set to 0U:
Example of Document Image
Filter set to 26U:
V - Blur Image
Smooths transitions by averaging the pixels next to the hard edges of defined
lines and shaded areas in an image.
0V
Don’t blur (default)
1V
Blur
Example of Blur Image Off (0V):
Example of Blur Image On (1V):
8 - 13
W - Histogram Ship
A histogram gives a quick picture of the tonal range of an image, or key type.
A low-key image has detail concentrated in the shadows; a high-key image
has detail concentrated in the highlights; and an average-key image has detail
concentrated in the midtones. This modifier ships the histogram for an image.
0W
Don’t ship histogram (default)
1W
Ship histogram
Image used for histogram:
Histogram of image at left:
Intelligent Signature Capture - IMGBOX
IMGBOX allows you to configure the size and location of a signature capture
area relative to its proximity to a barcode. This allows you to tailor a signature
capture area to a specific form. In order to use IMGBOX, you need a set form
where the signature box location is in a known location relative to a barcode.
You can input the overall size of the signature area, as well as specify how far
the signature area is from the barcode, vertically and horizontally. You can also
set the resolution and file format for the final output of the signature capture
image.
Note: IMGBOX commands can only be triggered by one of the following types of
barcodes: PDF417, Code 39, Code 128, Aztec, Codabar, and Interleaved
2 of 5. Once one of these symbologies has been read, the image is
retained for a possible IMGBOX command.
The following IMGBOX example was executed and viewed using QuickView
software. This software is available at www.honeywell.com/aidc. Click on Software Downloads. Select your device from the Products list, then select
QuickView Software Utility.
Below is an example of a signature capture application. In this example, the
aimer is centered over the signature capture area and the trigger is pressed. A
single beep is emitted, indicating that the imager has read a Code 128 barcode
and the data has been transferred to the host. An IMGBOX command may now
be sent from the host to specify the coordinates of the signature capture area
below that code, and indicating that only that area containing the signature
should be transferred as an image to the host.
8 - 14
To see this example, align the aimer with the signature area (not with the barcode), then press the trigger.
Send the following IMGBOX command string after the button push:
IMGBOX245w37h55y.
Note: Case is not important in the command string. It is used here only for clarity.
The following image is captured:
The IMGBOX commands have many different modifiers that can be used to
change the size and appearance of the signature image output by the imager.
Modifiers affect the image that is transmitted, but do not affect the image in
memory. Modifiers always begin with a number and end with a letter (case
insensitive). Any number of modifiers may be appended to the IMGBOX command.
Note: The IMGBOX command will return a NAK unless a window size (width and
height) are specified. See H - Height of Signature Capture Area (page 816) and W - Width of Signature Capture Area (page 8-18).
IMGBOX Modifiers
A - Output Image Width
This option is used to size the image horizontally. If using this option, set the
resolution (R) to zero.
Example of Image Width set to 200A:
Example of Image Width set to 600A:
8 - 15
B - Output Image Height
This option is used to size the image vertically. If using this option, set the
resolution (R) to zero.
Example of Image Height set to 50B:
Example of Image Height set to 100B:
D - Pixel Depth
This indicates the number of bits per pixel in the transmitted image, which
defines whether it will be grayscale or black and white.
8D
8 bits per pixel, grayscale image (default)
1D
1 bit per pixel, black and white image
F - File Format
This option indicates the type of file format in which to save the image.
0F
KIM format
1F
TIFF binary
2F
TIFF binary group 4, compressed
3F
TIFF grayscale
4F
Uncompressed Binary
5F
Uncompressed grayscale
6F
JPEG image (default)
7F
Outlined image
8F
BMP format
H - Height of Signature Capture Area
The height of the signature capture area must be measured in inches divided
by .01. In the example, the height of the area to be captured is 3/8 inch,
resulting in a value of H = .375/0.01 = 37.5.
Example: IMGBOX245w37h55y.
8 - 16
K - Gamma Correction
Gamma measures the brightness of midtone values produced by the image.
You can brighten or darken an image using gamma correction. A higher
gamma correction yields an overall brighter image. The lower the setting, the
darker the image. The optimal setting for text images is 50K.
0K
Gamma correction off (default)
50K
Apply gamma correction for brightening typical document image
nK
Apply gamma correction factor n (n = 1-255)
Example of Gamma Correction
set to 0K:
Example of Gamma Correction
set to 50K:
Example of Gamma Correction
set to 255K:
8 - 17
R - Resolution of Signature Capture Area
The resolution is the number of pixels that the imager outputs per each
minimum bar width. The higher the value for R, the higher the quality of the
image, but also the larger the file size. Values begin at 1000. The imager
automatically inserts a decimal point between the first and second digit. For
example, use 2500 to specify a resolution of 2.5. Set to zero when using the
A and B modifiers (see A - Output Image Width and B - Output Image
Height on page 8-16).
Example of Resolution set to 0R:
Example of Resolution set to 1000R:
Example of Resolution set to 2000R:
S - Barcode Aspect Ratio
All dimensions used in IMGBOX are measured as multiples of the minimum
element size of the barcode. The barcode aspect ratio allows you to set the
ratio of the barcode height to the narrow element width. In the example, the
narrow element width is .010 inches and the barcode height is 0.400 inches,
resulting in a value of S = 0.4/0.01 = 40.
W - Width of Signature Capture Area
The width of the signature capture area must be measured in inches divided
by .01. In the example, the width of the area to be captured is 2.4 inches,
resulting in a value of W = 2.4/0.01 = 240. (A value of 245 was used in the
example to accommodate a slightly wider image area.)
Example: IMGBOX245w37h55y.
8 - 18
X - Horizontal Barcode Offset
The horizontal barcode offset allows you to offset the horizontal center of the
signature capture area. Positive values move the horizontal center to the right
and negative values to the left. Measurements are in multiples of the minimum
bar width.
Example of Horizontal Offset set to 75X:
Example of Horizontal Offset set to -75X:
Y - Vertical Barcode Offset
The vertical barcode offset allows you to offset the vertical center of the
signature capture area. Negative numbers indicate that the signature capture
is above the barcode, and positive numbers indicate that the area is below the
barcode. Measurements are in multiples of the minimum bar width.
Example of Vertical Offset set to -7Y:
Example of Vertical Offset set to 65Y:
8 - 19
8 - 20
9
OCR Programming
Use this section to program the Imager for optical character recognition (OCR).
The 2D imager reads 6 to 60 point OCR typeface.
Note: OCR is not as secure as barcodes. To enhance security in OCR
applications, create an OCR template to match the data, and print an
OCR check character.
The 2D imager will read OCR-A, OCR-B, U.S. Currency Serial Number
(Money), MICR E-13B, and SEMI Font.
You can either select an OCR default, or create your own custom template for
the type of OCR format you intend to read. See "OCR" on page 9-1 for programming codes that will enable your imager to read OCR-A, OCR-B, U.S. Currency, MICR E 13 B, or SEMI fonts. See "OCR Templates" on page 9-3 if you
want to create a custom “template,” or character string that defines the length
and content of OCR strings that will be read with your imager.
Note: Setting the template and check character options are essential for OCR
reading.
OCR Fonts
Default All OCR Settings turns off all OCR capability in the imager, so the
imager will be able to scan linear, stacked, matrix, and composite barcodes, but
not OCR fonts. In addition, any OCR templates you have created are erased.
The eight digit default templates are reinstated for any future use of the OCR
On codes listed below.
< Default All OCR Settings >
OCR
Note: OCR symbols can misread when scanned sideways or upside down. Use
Working Orientation, page 3-22, if your OCR symbols will not usually be
presented upright to the imager.
Only one OCR symbology can be read at a time.
OCR-A On allows you to scan characters in the OCR-A font. The default setting allows you to scan any eight digit combination. If you have created an OCR
template, character combinations that fit the template can be scanned (see
Creating an OCR Template, page 9-3).
OCR-A On
9-1
OCR-B On allows you to scan characters in the OCR-B font. The default setting allows you to scan any eight digit combination. If you have created an OCR
template, character combinations that fit the template can be scanned (see
Creating an OCR Template, page 9-3).
OCR-B On
U.S. Currency Font
U.S. Currency On allows you to scan characters in the font used on U.S. currency. The default setting allows you to scan any eight digit combination. If you
have created an OCR template, character combinations that fit the template can
be scanned (see Creating an OCR Template, page 9-3).
U.S. Currency On
MICR E13 B Font
MICR E13 B On allows you to scan MICR characters on a bank check. The
default setting allows you to scan any eight digit combination. If you have created an OCR template, character combinations that fit the template can be
scanned (see Creating an OCR Template, page 9-3).
MICR E 13 B On
Note: TOAD characters (Transit, On Us, Amount and Dash) are output in the
following manner:
the transit character is output as T
the amount character is output as A
the on us character is output as O
the dash character is output as D
9-2
SEMI Font
SEMI Font On allows you to scan the SEMI font used in the semiconductor
industry.
SEMI Font On
All OCR Off turns off all OCR capability in the imager, so the imager will be able
to scan linear, stacked, matrix, and composite barcodes, but not OCR fonts.
However, any OCR templates you have created will be retained in memory.
* All OCR Off
OCR Templates
You can create a custom “template,” or character string that defines the length
and content of OCR strings that will be read with your imager. There are several choices when creating a custom template for your application. You can create a template for a single format, you can string together several formats, and
you can create a template for a user-defined variable. These choices are
described in detail below.
Creating an OCR Template
A single template allows you to program the imager to read any combination of
characters in the order you specify. Refer to examples that follow the Template
Characters table below.
9-3
Template Characters
a
represents any alphanumeric character (digit or letter)
c
represents that a check character is verified but not transmitted
d
represents any digit
e
represents any available OCR character
g
represents character from user-defined variable “g”
h
represents character from user-defined variable “h”
i
represents character from user-defined variable “g” or “h”
k
represents that a check character is verified but transmitted
l
represents any uppercase letter
t
marks the start of a new template
r
multi row indicator
All other characters represent themselves. Spaces can be used.
Note: In MICR E13 B templates, TOAD characters (capital letters T, O, A, and D),
represent Transit, On Us, Amount, and Dash.
Note: OCR templates default to eight digits, no check character.
To Add an OCR Template
1. Turn on the OCR font you want to read (page 9-1).
2. Begin building the template.
Scan the Enter OCR Template symbol (page 9-13).
3. Scan the characters for the string.
Use the Template Characters chart above to determine what characters you
need to create your format. Use the OCR Programming Chart (after the
Sample Codes in the back of this manual) to scan the characters for your
template.
Example: You need to read any combination of eight digits. The template
would be:
dddddddd
To create this template, you would enable the OCR-A font. Scan the Enter
OCR Template symbol (page 9-13), then scan the d from the OCR
Programming Chart in the back of this manual eight times. Scan Save OCR
Template (page 9-13). This would let you read any string of eight digits, for
example:
37680981
9-4
Character Match Sequences
This method is used if you need a template that shows a specific character in
a specific position. Put the character in uppercase in the template at the
required position (template characters are always lower case).
Example: You need to read three variable digits, three specific characters
(ABC), followed by three variable digits. The template would be:
dddABCddd
Using Visual Xpress (see page 11-4), you can enter the template as shown
above, enclosing the whole string between quotes: “dddABCddd”.
You may also create this character match sequence by scanning barcodes.
Scan the Enter OCR Template symbol (page 9-13). Scan the d from the
OCR Programming Chart in the back of this manual three times. Then scan
414243 from the inside back cover (the hex characters for “A,” “B,” and “C”),
and scan the d three more times. Scan Save OCR Template, page 9-13.
This would let you read any string of three digits, “ABC,” then any string of
three digits, for example:
551ABC983
(The above OCR sample is OCR-A. You must enable the OCR-A font (page
9-1) in order to read it.)
Adding Spaces
You may also need to put spaces in your template. A space is seen as a
character, therefore you can use the directions for Character Match
Sequences, above, to add spaces to a string. (The hex value for a space is
20.)
4. Exit OCR Template Editor
Scan Save OCR Template to save your entries. Discard OCR Template
exits without saving any OCR Template changes.
Stringing Together Multiple Formats
(Creating “Or” Statements)
You may want to program the imager to accept many OCR formats. To do this,
you would string together each format with a “t.” This tells the imager to read
optical characters that match any one of the formats in the template.
Example: You need to read any combination of eight digits, or a combination
of four digits, two uppercase letters, and two digits. The template
would be:
ddddddddtddddlldd
9-5
To create this template, you would enable the OCR-A font. Scan the Enter
OCR Template symbol (page 9-13). Scan the d from the OCR Programming
Chart in the back of this manual eight times, then scan the t to create the “or”
statement. Then you would scan the characters for the second template.
Scan d four times, scan l two times, then scan d two more times. Scan Save
OCR Template (page 9-13). This would let you read either type of format, for
example:
99028650
or
9902XZ50
You can string together as many templates as you need.
OCR User-Defined Variables
You can create up to two of your own user variables for an OCR template.
These variables will represent any OCR readable characters. The user-defined
variables are stored under the letters “g” and “h.” You need a variable to represent the letters “A,” “B,” or “C.” The template for this user-defined variable
would be:
ABC
Using Visual Xpress (see page 11-4), you can enter the string as shown above
into the “G variable” text box. You must enclose the strings between quotes:
“ABC”.
You may also create this user-defined variable by scanning barcodes. Scan the
Enter User-Defined Variable g symbol (page 9-13). Then scan 414243 from
the inside back cover (the hex characters for “A,” “B,” and “C”), Scan Save OCR
Template, page 9-13. This will let you read either A or B or C in any position
where you place the g in the template. For example, you could create the following template:
ddddddggg
(Using Visual Xpress, you must enter “ddddddggg” in the Template text box.)
This template would then let you read data that began with six digits, and had
an A, B, or C trailing. So you would be able to read:
654321ABC
or
654321BAC
or
654321CCC
(The above OCR sample is OCR-A. You must enable the OCR-A font (page 91) in order to read it.)
9-6
Reading Multi-Row OCR
The imager is capable of decoding multi-row OCR text.
Note: Reading rows longer than sixteen characters is not recommended.
Consider the following example. This example shows serial commands as they
would be entered using Quick*View.
Example: You need to read multiple rows of OCR-A data as shown below:
12345678
ABCDEFGH
First, enable the OCR-A font. To read the first row of OCR data, you would
program the following template:
OCRTMP"dddddddd".
This template is the default OCR template. If you wanted to read the second
line of data, you would use the following template:
OCRTMP"llllllll".
To read both lines of OCR at one time, use the variable r to indicate the start
of a new row. All the other templating variables for the individual rows work
the same as previously described. For instance, in the above example, you
would use the following template to read both rows:
OCRTMP"ddddddddrllllllll".
To read the three rows below, you would use the template command
"OCRTMP"ddddddddrllllllllrlllldddd".
12345678
ABCDEFGH
ABCD1234
OCR Check Character
You may want to print and verify a check character in order to enhance the
security of your OCR application. The imager can be programmed for almost
any type of check character. A number of presets are provided for common
check character uses (e.g., modulo 10 and modulo 36).
Scan the OCR Modulo 10 or OCR Modulo 36 Check Character barcode to
specify the type of check character used in the OCR strings you’re scanning.
The imager will then only read OCR character strings with a valid check character. The imager transmits the OCR data without the check character data. You
must specify the location of the check character in the template with a c.
9-7
Example: You need to read any combination of seven digits, with a modulo 10
check character in the eighth position. The template would be:
dddddddc
To create this template, you would enable the OCR-A font. Scan the Modulo
10 Check Character symbol. Then scan the Enter OCR Template symbol,
and scan the d from the OCR Programming Chart seven times, and scan the
c once. Scan Save OCR Template (page 9-13). This template will let you
read any combination of six digits with a correct check character after. (If the
check character is invalid, the data is discarded.) For example, the following
string could be scanned:
01234569
and the output would be: 0123456
OCR Modulo 10 Check Character
Scan this symbol to program the OCR template for a simple modulo 10 checksum of the digits 0 through 9.
OCR Modulo 10 Check Character
OCR Modulo 36 Check Character
Scan this symbol to program the OCR template for a simple modulo 36 checksum of the digits 0 through 9 and the letters A through Z.
OCR Modulo 36 Check Character
OCR User-Defined Check Character
You can customize the check character calculation to suit your application.
Each character of the check character alphabet can be programmed in its
proper order. The number of characters you enter determines the modulo value
for the calculation. By default, the check character computation is unweighted,
but the imager also supports two weighted modulo 10 checking schemes.
Example: To program a modulo 11 check character, you would enter the
following 11 characters in order:
9-8
0123456789X
Also enter the OCR template:
dddddddc
Enable the OCR-A font, then scan the following string:
6512351X
The imager performs the following check character computation:
(6 + 5 + 1 + 2 +3 + 5 + 1 + X) modulo 11 = 0
Since the result is zero, the message is considered to be valid, so the reader
outputs the message: 6512351
Programming a User-Defined Check Character
1. Scan the Enter OCR Check Character barcode, below.
Enter OCR Check Character
2. Enter the characters in order. For each character, look up the corresponding
hex value from the ASCII Conversion Chart (Code Page 1252), page A-4.
Use the Programming Chart on the inside the back cover of this manual to
scan the two symbols for each hex value.
3. Scan the Save barcode on the inside back cover.
Example: To program the modulo 11 check character from example #8 on
page 9-8, enable the OCR-A font. Scan the Enter OCR Check
Character barcode on page 9-9, then scan the following hex values
in order:
3031323334353637383958
After you enter all the desired hex values, scan the Save barcode on the
inside back cover of this manual.
Weighting Options
By default, the check character computation is unweighted. It is possible to use
one of two weighted modulo 10 schemes. Weighting is often used to detect if
two neighboring characters are transposed, a common error when an operator
keys in data.
9-9
3-1-3-1 Weighted Modulo 10 Check Character
Starting with the check character and working backward through the message,
the imager applies a multiplier of 1, then 3, then 1, then 3, and so on. This is
the checking scheme used in many GS1 symbologies, including U.P.C. and
Interleaved 2 of 5 (when a check digit is invoked). To apply this weighting
scheme, set the OCR check character to “0123456789x3x1” or scan the following symbol:
3-1-3-1 Weighted Modulo 10
Check Character
Example: Scan the 3-1-3-1 Weighted Modulo 10 Check Character symbol. Also
enter the OCR template:
dddddddc
Then scan the string below:
01234565
The reader performs the check character computation below:
(0 x 3 + 1 x 1 + 2 x 3 + 3 x 1 + 4 x 3 + 5 x 1 + 6 x 3 + 5 x 1) modulo 10 = 0
Since the result is zero, the message is considered to be valid, so the reader
outputs the message: 0123456
2-1-2-1 Weighted Modulo 10 Check Character
Starting with the check character and working backward through the message,
the imager applies a multiplier of 1, then 2, then 1, then 2, and so on. When the
result of the multiplication is greater than 9, add both digits to the running sum.
This is often referred to as the LUHN formula. One common application of the
LUHN formula is validate credit card numbers. This is the modulo 10 checking
scheme used in MSI Code and in Code 32 Pharmaceutical (PARAF). To apply
this weighting scheme, set the OCR check character to "0123456789x2x1" or
scan the following symbol:
2-1-2-1 Weighted Modulo 10
Check Character
Example: Scan the 2-1-2-1 Weighted Modulo 10 Check Character symbol. Also
enter the OCR template:
ddddddc
9 - 10
Then scan the string below:
0128454
The reader performs the check character computation below:
(0 x 1 + 1 x 2 + 2 x 1 + 8 x 2 + 4 x 1 + 5 x 2 + 4 x 1) modulo 10
= (0 + 2 + 2 + (1 + 6) + 4 + (1 + 0) + 4) modulo 10
=0
Since the result is zero, the message is considered to be valid, so the reader
outputs the message: 012845
OCR ISBN Application Example
One application of OCR is to read the ISBN characters typically encoded using
the OCR-A or OCR-B font. This is especially useful when the ISBN number is
not encoded in an EAN-13 barcode. The following example shows how to configure the imager to read the ISBN strings on books in Japan. After you have
followed the steps below, you will be able to scan the following ISBN number or
the additional data below it, depending on the line of text at which the imager is
aimed.
1. Scan the OCR-B On barcode on page 9-2.
2. Program the user-defined variable “g” to comprise the ten digits plus the
dash:
01234567893. In Japan, it is common for two fields to follow the ISBN number, the three
digit price field, and the four digit price field. The first field typically starts
with a “C” (uppercase c), followed by four digits. The second field typically
starts with a “P” or a yen symbol, followed by three or four digits, followed by
an “E.” Program the user-defined variable “h” to comprise the “P” and the
yen symbol (represented by a backslash).
P\
9 - 11
4. Scan the symbol below to set up three templates to handle the ISBN
number, the three digit price field, and the four digit price field.
5. Finally, set up the ISBN check digit, which is a special position-weighted
modulo 11 checksum. The imager automatically invokes the ISBN
checksum for template rows that are:
1.) at least fourteen characters long,
2.) whose first four characters are the letters “ISBN,”
3.) whose last character is a check character, and
4.) when the modulo 11 check character “0123456789X” is programmed.
Please note that all these commands can be combined into a single serial programming command:
OCRENA2,TMP”ISBNggggggggggggctCdddd hdddEtCdddd
hddddE”,GPG”0123456789-”,GPH”P\”,CHK”0123456789X”.
These commands can be encoded into the following Aztec Code symbol:
9 - 12
OCR Template Codes
Note: Reading more than three rows of OCR is not recommended. Contact the
factory if you have an application that requires reading four or more rows
of OCR.
Enter OCR Template †
Enter User-Defined
Variable “g”†
Enter User-Defined
Variable “h”†
† One or more two-digit numbers and Save are required after reading this programming symbol. Refer to the Programming Chart on the inside the back
cover of this manual.
Exit Selections
Save OCR Template
Discard OCR Template
9 - 13
9 - 14
10
Interface Keys
Keyboard Function Relationships
The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII
“CTRL”+ relationships apply to all terminals that can be used with the imager.
Refer to page 2-7 enable Control + ASCII mode.
Function Code
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
HEX/ASCII Value
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Full ASCII “CTRL” +
@
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
\
]
^
_
10 - 1
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to
US only. The following chart indicates the equivalents of these five characters
for different countries.
Country
Codes
United States
[
\
]
6
-
Belgium
[
<
]
6
-
Scandinavia
8
<
9
6
-
France
^
8
$
6
=
Germany
Ã
+
6
-
Italy
\
+
6
-
Switzerland
<
..
6
-
United Kingdom
[
¢
]
6
-
Denmark
8
\
9
6
-
Norway
8
\
9
6
-
Spain
[
\
]
6
-
10 - 2
Supported Interface Keys
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
IBM AT/XT and
PS/2 Compatibles,
WYSE PC/AT
Supported Keys
Reserved
Enter (KP)
Cap Lock
ALT make
ALT break
CTRL make
CTRL break
CR/Enter
Reserved
Tab
Reserved
Tab
Delete
CR/Enter
Insert
Escape
F11
Home
Print
Back Space
Back Tab
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
IBM XTs and
Compatibles
Supported Keys
Reserved
CR/Enter
Caps Lock
Reserved
Reserved
Reserved
Reserved
CR/Enter
Reserved
Tab
Reserved
Tab
Delete
CR/Enter
Insert
Escape
Reserved
Home
Print
Back Space
Back Tab
Reserved
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
IBM, DDC, Memorex
Telex, Harris*
Supported Keys
Reserved
Enter
F11
F12
F13
F14
F15
New Line
F16
F17
F18
Tab/Field Forward
Delete
Field Exit/New Line
Insert
F19
Error Reset
Home
F20
Back Space
Backfield/Back Tab
F21
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
* IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models)
10 - 3
Supported Interface Keys
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
IBM, Memorex Telex (102)*
Supported Keys
Reserved
Enter
F11
F12
F13
F14
F15
New Line
F16
F17
F18
Tab/Field Forward
Delete
Field Exit
Insert
Clear
Error Reset
Home
Print
Back Space
Back Tab
F19
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Memorex Telex (88)**
Supported Keys
Reserved
Enter
PF10
PF11
PF12
Reserved
Reserved
New Line
Field Forward
Field Forward
Reserved
Field Forward
Delete
New Line
Insert
Erase
Error Reset
Reserved
Print
Back Space
Back Field
Reserved
PF1
PF2
PF3
PF4
PF5
PF6
PF7
PF8
PF9
Home
* IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102
key keyboards
** Memorex Telex with 88 key keyboards
10 - 4
Supported Interface Keys
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Esprit 200, 400
ANSI
Supported Keys
Reserved
New Line
N/A
N/A
N/A
N/A
N/A
New Line
N/A
Tab
N/A
Tab
N/A
New Line
N/A
Escape
F11
Insert
F13
Back Space
Back Tab
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Esprit 200, 400
ASCII
Supported Keys
Reserved
New Line
N/A
N/A
N/A
N/A
N/A
New Line
N/A
Tab
N/A
Tab
N/A
New Line
N/A
Escape
F11
Insert
F13
Back Space
Back Tab
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Esprit 200, 400
PC
Supported Keys
Reserved
New Line
N/A
N/A
N/A
N/A
N/A
New Line
N/A
Tab
N/A
Tab
Delete
New Line
Insert
Escape
F11
Home
Print
Back Space
Back Tab
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
10 - 5
Supported Interface Keys
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
DEL
10 - 6
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
7F
Apple Mac/iMac
Supported Keys
Reserved
Enter/Numpad Enter
CAPS
ALT make
ALT break
CNTRL make
CNTRL break
RETURN
APPLE make
TAB
APPLE break
TAB
Del
RETURN
Ins Help
ESC
F11
Home
Prnt Scrn
BACKSPACE
LSHIFT TAB
F12
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
BACKSPACE
11
Utilities
To Add a Test Code I.D. Prefix to All Symbologies
This selection allows you to turn on transmission of a Code I.D. before the
decoded symbology. (See the Symbology Chart, page A-1, for the single character code that identifies each symbology.) This action first clears all current
prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled.
Add Code I.D. Prefix to
All Symbologies (Temporary)
Show Decoder Revision
Scan the barcode below to output the decoder revision.
Note: You may use the Show Decoder Revision option if you have firmware with
a base number of 31205480. Refer to Show Software Revision on page
11-2 for information on determining the firmware revision in your unit.
Show Decoder Revision
Show Engine Revision
Note: You may use the Show Engine Revision option if you have firmware with
a base number of 31205480.
Scan the barcode below to output the engine revision. Your imager returns the
engine type, revision number, and status character [ACK]. For example, an
imager with a 5100 engine, version 26 would return:
ENGREVType:
1
Revision: 26[ACK]
Show Engine Revision
11 - 1
Show Scan Driver Revision
Scan the barcode below to output the scan driver revision. The scan driver controls image capture.
You may use the Show Scan Driver Revision option if you have firmware with a
base number of 31205480. Refer to the Show Software Revision below for
information on determining the firmware revision in your unit.
Show Scan Driver Revision
Show Software Revision
Scan the barcode below to output the current software revision, unit serial number, and other product information.
Show Software Revision
Show Data Format
Scan the barcode below to show current data format settings.
Data Format Settings
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your imager, or you’ve
changed some options and want the standard product default settings restored,
scan the Standard Product Default Settings barcode below.
Standard Product Default Settings
The Menu Commands starting on page 12-4 lists the standard product default
settings for each of the commands (indicated by an asterisk (*) on the programming pages).
11 - 2
Test Menu
When you scan the Test Menu On code, then scan a programming code in this
manual, the imager displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming
code is output to the terminal.
Note: This feature should not be used during normal imager operation.
On
* Off
2D PQA (Print Quality Assessment)
Two-dimensional Print Quality Assessment (2D PQA) is a feature of Honeywell’
image readers where the data from the successful read of a 2D barcode symbol
is augmented with lines of text that both identify the symbol, and also report
graded measurement parameters obtained from it.
2D PQA Reporting
Honeywell' 2D PQA reporting can be enabled in two different modes: Full
Report or Screening. (To see displayed results, Microsoft® Notepad, a word
processor/editing program, or Quick*View (page 11-6) is recommended.)
If you are using Quick*View, you can enable Full Report, a listing of all of a symbol's identifying information, measurements, and corresponding grades, by typing the following menu command:
2D_PQA1
or by scanning the following barcode:
Full Report
Note: The PQA report is sent out as a second data/beep sequence after the
barcode data. The report has its own Honeywell code ID of >(0X3E) so
it can be uniquely identified.
11 - 3
You can exit Full Report mode by either typing the menu command, 2D_PQA0,
if you are using Quick*View, or by scanning the following barcode:
Exit
Note: For additional information on interpreting your read results, please refer
to Honeywell Quick Check 2D Print Assessment User’s Guide.
Visual Xpress Introduction
Note: Software revision 31205480-118 or higher is backward compatible with
all non-advanced illumination units. This new revision of software can be
flashed in non-advanced illumination units for full backward compatibility.
Software 31205480-090 or lower cannot be flashed into units with
advanced illumination. Visual Xpress will display an incompatibility error
message.
Non-Advanced
Illumination Unit
Advanced
Illumination Unit
Visual Xpress provides a wide range of PC-based programming functions that
can be performed on an imager connected to your PC's COM port. Visual
Xpress allows you to download upgrades to the imager's firmware, change programmed parameters, and create and print programming barcodes. Using
Visual Xpress, you can even save/open the programming parameters for an
imager. This saved file can be e-mailed or, if required, you can create a single
barcode that contains all the customized programming parameters and mail or
fax that barcode to any location. Users in other locations can scan the barcode
to load in the customized programming.
To communicate with an imager, Visual Xpress requires that the PC have at
least one available serial communication port, or a serial port emulation using a
physical USB port. If you are using the serial port and RS-232 cable, an external power supply is required. When using a USB serial port emulation, only a
USB cable is required.
Visual Xpress Operations
The Visual Xpress software performs the following operations:
11 - 4
Scan Data
Scan Data allows you to scan barcodes and display the barcode data in a window. Scan Data lets you send serial commands to the imager and receive
imager response that can be seen in the Scan Data window. The data displayed in the Scan Data window can either be saved in a file or printed.
Configure
Configure displays the programming and configuration data of the imager. The
imager's programming and configuration data is grouped into different categories. Each category is displayed as a tree item under the "Configure" tree node
in the application explorer. When one of these tree nodes is clicked, the righthand side is loaded with the parameters' form belonging to that particular category. The "Configure" tree option has all the programming and configuration
parameters specified for an imager. You can set or modify these parameters as
required. You can later write the modified settings to the imager, or save them
to a dcf file.
Imaging
Imaging provides all the image-related functions that a 2D Imager can perform.
You can capture an image using the current settings, and the image will be displayed in an image window. Images captured from the imager can be saved to
files in different image formats. You can modify the image settings and save the
image settings to an INI file, which can be loaded later to capture new images.
Imaging also lets you preview the images continuously captured by the imager.
Installing Visual Xpress from the Web
Note: Visual Xpress requires .NET software. If .NET is not installed on your PC,
you will be prompted to install it during the Visual Xpress installation.
1. Access the Honeywell web site at www.honeywell.com/aidc.
2. Click on the Resources tab. Select Product Downloads-Software.
3. Click on the dropdown for Select Product Number. Click on 4600g.
4. Click on the listing for Visual Xpress.
5. When prompted, select Save File, and save the files to the
c:\windows\temp directory.
6. Once you have finished downloading the file, exit the web site.
7. Using Explorer, go to the c:\windows\temp file and unzip the file you saved.
8. Double click on Setup.exe and follow the screen prompts to install the
Visual Xpress program.
9. If you’ve selected the defaults during installation, you can click on Start
Menu-All Programs-Hand Held Products-Visual Xpress.
11 - 5
Quick*View
Quick*View is a Microsoft Windows® program that displays decoded symbol
messages and captures images (for instance, ID photographs) from the imager.
Barcode information and images are displayed in the Quick*View window.
Installing Quick*View from the Web
1. Access the Honeywell web site at www.honeywell.com/aidc.
2. Click on the Resources tab. Select Product Downloads-Software.
3. Click on the dropdown for Select Product Number. Click on 4600g.
4. Click on the listing for Quick*View Software Utility.
5. When prompted, select Save, and save the files to the c:\windows\temp
directory.
6. Once you have finished downloading the file, exit the web site.
7. Using Explorer, go to the c:\windows\temp file.
8. Double click on the Quickview.exe file. Follow the screen prompts to install
the Quick*View program.
9. To start Quick*View, from the Start Menu click on All ProgramsQuick*View-Quick*View.
Note: If you wish, you can create a shortcut to the Quick*View executable on
your desktop.
Temporary Quick*View Configuration
For a quick download communication configuration, scan the Quick*View barcode and the imager will be temporarily configured for Quick*View settings.
Note: If you have a unit capable of keyboard wedge mode, scan the barcode
below and the unit will communicate in RS-232 mode, allowing it to work
with Quick*View. To convert the imager back to keyboard wedge
communication, cycle the power.
Quick*View
11 - 6
12
Serial Programming Commands
The serial programming commands can be used in place of the programming
barcodes. Both the serial commands and the programming barcodes will program your imager. For complete descriptions and examples of each serial programming command, refer to the corresponding programming barcode in this
manual.
The device must be set to an RS-232 interface (see page 1-11). The following
commands can be sent via a PC COM port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameter A label representing the actual value you should send as part of a
command.
[option]
An optional part of a command.
{Data}
Alternatives in a command.
bold
Names of menus, menu commands, buttons, dialog boxes, and
windows that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage
Prefix
Three ASCII characters: SYN M CR (ASCII 22,77,13).
Tag
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS-232 configuration settings
are identified with a Tag of 232.
SubTag
A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS-232 baud rate is BAD.
Data
The new value for a menu setting, identified by the Tag and SubTag.
Storage
A single character that specifies the storage table to which the
command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table.
A period (.) performs the command’s operation on the device’s
non-volatile menu configuration table. Use the non-volatile table
only for semi-permanent changes you want saved through a power
cycle.
12 - 1
Query Commands
Several special characters can be used to query the device about its settings.
^
?
*
What is the default value for the setting(s).
What is the device’s current value for the setting(s).
What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of
values. A pipe (|) separates items in a list of non-continuous values.)
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire set
of commands available for the particular storage table indicated by the Storage
field of the command. In this case, the SubTag and Data fields should not be
used because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the
subset of commands available that match the Tag field. In this case, the Data
field should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to the
specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence. Only
the Tag, SubTag, and Data fields must be repeated for each command in the
sequence. If additional commands are to be applied to the same Tag, then the
new command sequence is separated with a comma (,) and only the SubTag
and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous
commands by a semicolon (;).
Responses
The device responds to serial commands with one of three responses:
ACK Indicates a good command which has been processed.
ENQ Indicates an invalid Tag or SubTag command.
NAK Indicates the command was good, but the Data field entry was out of the
allowable range for this Tag and SubTag combination, e.g., an entry for a
minimum message length of 100 when the field will only accept 2 characters.
When responding, the device echoes back the command sequence with the
status character inserted directly before each of the punctuation marks (the
period, exclamation point, comma, or semicolon) in the command.
12 - 2
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example #1:What is the range of possible values for Codabar Coding Enable?
Enter:
cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example #2: What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example #3: What is the device’s current setting for Codabar Coding Enable?
Enter:
cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example #4: What are the device’s settings for all Codabar selections?
Enter:
cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
12 - 3
Trigger Commands
You can activate and deactivate the imager with serial trigger commands. First,
the imager must be put in Manual/Serial Trigger Mode either by scanning the
Manual/Serial Trigger Mode barcode (page 3-4), or by sending the Manual/
Serial Menu Command (page 12-9). Once the imager is in serial trigger mode,
the trigger is activated and deactivated by sending the following commands:
Activate: SYN T CR
Deactivate: SYN U CR
The imager scans until a barcode has been read, until the deactivate command
is sent, or until the serial time-out has been reached (see "Read Time-Out" on
page 3-4 for a description, and the serial command on page 12-9).
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your imager, or you’ve
changed some options and want the factory settings restored, scan the Standard Product Default Settings barcode below.
Standard Product Default Settings
The chart on the following pages lists the factory default settings for each of the
menu commands (indicated by an asterisk (*) on the programming pages).
Menu Commands
Note: Not all menu commands apply to all imager models.
Selection
Factory Default
Settings
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Default
DEFALT
12-4
TERMID###
2-1
Terminal Interfaces
Terminal ID
12 - 4
000 (4600g/4600r/4600rp/
4800i 030 models)
124 (4600g/4600r/4600rp/
4800i 050 models)
Selection
Program
Keyboard
Country
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
*U.S.A.
KBDCTY0
2-4
Belgium
KBDCTY1
2-4
Brazil
KBDCTY16
2-4
Canada (French)
KBDCTY18
2-4
Czech Republic
KBDCTY15
2-4
Denmark
KBDCTY8
2-4
Finland (Sweden)
KBDCTY2
2-4
France
KBDCTY3
2-4
Germany/Austria
KBDCTY4
2-4
Greece
KBDCTY17
2-4
Hungary
KBDCTY19
2-4
Israel (Hebrew)
KBDCTY12
2-4
Italy
KBDCTY5
2-5
Latin America
KBDCTY14
2-5
Netherlands (Dutch)
KBDCTY11
2-5
Norway
KBDCTY9
2-5
Poland
KBDCTY20
2-5
Portugal
KBDCTY13
2-5
Romania
KBDCTY25
2-5
Russia
KBDCTY26
2-5
SCS
KBDCTY21
2-5
Slovakia
KBDCTY22
2-5
Spain
KBDCTY10
2-5
Sweden
KBDCTY23
2-5
Switzerland (German)
KBDCTY6
2-5
Turkey F
KBDCTY27
2-6
Turkey Q
KBDCTY24
2-6
U.K.
KBDCTY7
2-6
12 - 5
Selection
Keyboard Style
Keyboard
Modifiers
Baud Rate
12 - 6
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
*Regular
KBDSTY0
2-6
Caps Lock
KBDSTY1
2-6
Shift Lock
KBDSTY2
2-7
Automatic Caps Lock
KBDSTY6
2-7
Emulate External
Keyboard
KBDSTY5
2-7
*Control + ASCII Off
KBDCAS0
2-8
DOS Mode Control + ASCII
KBDCAS1
2-8
Windows Mode Control +
ASCII
KBDCAS2
2-8
*Turbo Mode Off
KBDTMD0
2-8
Turbo Mode On
KBDTMD1
2-8
*Numeric Keypad Off
KBDNPS0
2-8
Numeric Keypad On
KBDNPS1
2-8
*Auto Direct Conn. Off
KBDADC0
2-9
Auto Direct Conn. On
KBDADC1
2-9
300 BPS
232BAD0
2-10
600 BPS
232BAD1
2-10
1200 BPS
232BAD2
2-10
2400 BPS
232BAD3
2-10
4800 BPS
232BAD4
2-10
9600 BPS
232BAD5
2-10
19200 BPS
232BAD6
2-10
*38400 BPS
232BAD7
2-10
57600 BPS
232BAD8
2-10
115200 BPS
232BAD9
2-10
Selection
Word Length:
Data Bits, Stop
Bits, and Parity
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
7 Data, 1 Stop, Parity Even
232WRD3
2-11
7 Data, 1 Stop, Parity None
232WRD0
2-11
7 Data, 1 Stop, Parity Odd
232WRD6
2-11
7 Data, 2 Stop, Parity Even
232WRD4
2-11
7 Data, 2 Stop, Parity None
232WRD1
2-11
7 Data, 2 Stop, Parity Odd
232WRD7
2-11
8 Data, 1 Stop, Parity Even
232WRD5
2-11
*8 Data, 1 Stop, Parity None
232WRD2
2-11
8 Data, 1 Stop, Parity Odd
232WRD8
2-11
RS-232
Receiver Timeout
Range 0 - 300 seconds
232LPT###
2-12
RS-232
Handshaking
*RTS/CTS Off
232CTS0
2-12
RTS/CTS On
232CTS1
2-12
*XON/XOFF Off
232XON0
2-12
XON/XOFF On
232XON1
2-12
*ACK/NAK Off
232ACK0
2-12
ACK/NAK On
232ACK1
2-12
Wand Emulation
Connection
Same Code Format
TERMID64
2-13
Code 39 Format
TERMID61
2-13
Data Block Size
20
WNDBLK0
2-13
*40
WNDBLK1
2-13
60
WNDBLK2
2-13
80
WNDBLK3
2-13
5ms
WNDDLY0
2-14
*50ms
WNDDLY1
2-14
150ms
WNDDLY2
2-14
500ms
WNDDLY3
2-14
On
WNDCHK1
2-14
*Off
WNDCHK0
2-14
Delay Between
Blocks
Overall
Checksum
12 - 7
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
10
WNDSPD0
2-15
*25
WNDSPD1
2-15
40
WNDSPD2
2-15
80
WNDSPD3
2-15
120
WNDSPD4
2-15
150
WNDSPD5
2-15
200
WNDSPD6
2-15
Wand Emulation
Polarity
*Black High
WNDPOL0
2-15
White High
WNDPOL1
2-15
Wand Emulation
Idle
Idle Low
WNDIDL0
2-16
*Idle High
WNDIDL1
2-16
Wand Emulation
Transmission
Rate
Output Selections
Beeper - Good
Read
Off
BEPBEP0
3-1
*On
BEPBEP1
3-1
Beeper Volume Good Read
Off
BEPLVL0
3-1
Low
BEPLVL1
3-1
*Medium (default for 4600g/
4600r/4600rp)
BEPLVL2
3-1
*High (default for 4800i)
BEPLVL3
3-1
Beeper Pitch Good Read
(Frequency)
Low (1600) (min 400Hz)
BEPFQ11600
3-2
*Medium (3250)
BEPFQ13250
3-2
High (4200) (max 9000Hz)
BEPFQ14200
3-2
Beeper Duration
- Good Read
*Normal Beep
BEPBIP0
3-2
Short Beep
BEPBIP1
3-2
LED - Good
Read
Off
BEPLED0
3-2
*On
BEPLED1
3-2
Number of
Beeps - Good
Read
*1
BEPRPT1
3-3
Range 1 - 9
BEPRPT#
3-3
12 - 8
Selection
Good Read
Delay
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
*No Delay
DLYGRD0
3-3
Short Delay (500 ms)
DLYGRD500
3-3
Medium Delay (1000 ms)
DLYGRD1000
3-3
3-3
Long Delay (1500 ms)
DLYGRD1500
User-Specified
Good Read
Delay
Range 0 - 30,000 ms
DLYGRD#####
3-3
Manual/Serial
Trigger
*Manual/Serial Trigger Mode
TRGMOD0
3-4
Read Time-Out
(0 - 300,000 ms) *30,000
TRGSTO####
3-4
Manual Trigger,
Low Power
Manual Trigger, Low Power
Mode
TRGMOD2
3-4
Low Power Time-Out Timer
( 0 - 300 seconds) *120
TRGLPT###
3-5
In-Stand Sensor
Mode
*Off
TRGSSW0
3-5
On
TRGSSW1
3-5
Scan Stand
Scan Stand Mode
TRGMOD4
3-6
Scan Stand Symbol
FNC3
3-6
Presentation
Presentation Mode
TRGMOD3
3-7
Presentation
LED Timer
LEDs Off
TRGPCK0
3-7
*LEDs On
TRGPCK1
3-7
Presentation
Sensitivity
Range 0-20 (*1)
TRGPMS##
3-8
Streaming
Presentation
Streaming Presentation Mode
TRGMOD8
3-8
Hands Free
Time-Out
Range 0 - 300,000 ms
TRGPTO######
3-9
Reread Delay
Short (500 ms)
DLYRRD500
3-10
*Medium (750 ms)
DLYRRD750
3-10
Long (1000 ms)
DLYRRD1000
3-10
Extra Long (2000 ms)
DLYRRD2000
3-10
Range 0 - 30,000 ms
DLYRRD#####
3-10
User-Specified
Reread Delay
12 - 9
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Off
PWRLDC0
3-11
Low (50%)
PWRLDC50
3-11
*High (100%)
PWRLDC100
3-11
Illumination
Lights
*Lights On
SCNLED1
3-11
Lights Off
SCNLED0
3-11
Imager TimeOut
Range 0 - 999,999 ms
(*60,000 ms)
SDRTIM######
3-11
Aimer Delay
200 milliseconds
SCNDLY200
3-12
400 milliseconds
SCNDLY400
3-12
LED Power
Level
*Off (no delay)
SCNDLY0
3-12
User-Specified
Aimer Delay
Range 0 - 4,000 ms
SCNDLY####
3-12
Aimer Mode
Off
SCNAIM0
3-13
* Interlaced
SCNAIM2
3-13
Centering On
DECWIN1
3-14
*Centering Off
DECWIN0
3-14
Left of Centering Window
(*40%)
DECLFT
3-14
Right of Centering Window
(*60%)
DECRGT
3-14
Top of Centering Window
(*40%)
DECTOP
3-14
Bottom of Centering Window
(*60%)
DECBOT
3-14
*Full Omnidirectional
DECMOD0
3-15
Quick Omnidirectional
DECMOD1
3-15
Advanced Linear Decoding
DECMOD2
3-15
Centering
Window
Decode Search
Mode
12 - 10
Selection
Preferred
Symbology
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
On
PRFENA1
3-16
*Off
PRFENA0
3-16
High Priority Symbology
PRFCOD##
3-16
Low Priority Symbology
PRFBLK##
3-16
Preferred Symbology Timeout
PRFPTO####
3-17
3-17
Preferred Symbology Default
PRFDFT
Output
Sequence Editor
Enter Sequence
SEQBLK
3-20
Default Sequence
SEQDFT
3-20
Require Output
Sequence
Required
SEQ_EN2
3-20
On/Not Required
SEQ_EN1
3-20
*Off
SEQ_EN0
3-20
Multiple
Symbols
On
SHOTGN1
3-21
*Off
SHOTGN0
3-21
No Read
On
SHWNRD1
3-21
*Off
SHWNRD0
3-21
Set Print Weight (1-7)
PRTWGT
3-21
*Default (4)
PRTWGT4
3-21
On
VIDREV1
3-22
*Off
VIDREV0
3-22
*Upright
ROTATN0
3-23
Rotate Code Clockwise 90°
ROTATN1
3-23
Upside Down
ROTATN2
3-23
Rotate Code
Counterclockwise 90°
ROTATN3
3-23
Add CR Suffix to All Symbologies
VSUFCR
4-3
Prefix
Add Prefix
PREBK2##
4-4
Clear One Prefix
PRECL2
4-4
Clear All Prefixes
PRECA2
4-4
Print Weight
Video Reverse
Working
Orientation
Prefix/Suffix Selections
12 - 11
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Add Suffix
SUFBK2##
4-4
Clear One Suffix
SUFCL2
4-4
Clear All Suffixes
SUFCA2
4-4
Function Code
Transmit
*Enable
RMVFNC0
4-4
Disable
RMVFNC1
4-4
Intercharacter
Delay
Range 0 - 495 ms
DLYCHR##
4-5
User Specified
Intercharacter
Delay
Delay Length
(0 - 495 ms)
DLYCRX##
4-6
Character to Trigger Delay
DLY_XX###
4-6
Interfunction
Delay
Range 0 - 495 ms
DLYFNC##
4-6
Intermessage
Delay
Range 0 - 495 ms
DLYMSG##
4-7
*Default Data Format (None)
DFMDF3
5-5
Enter Data Format
DFMBK3##
5-5
Clear One Data Format
DFMCL3
5-5
Clear All Data Formats
DFMCA3
5-5
Suffix
Data Formatter Selections
Data Format
Editor
Data Formatter
Alternate Data
Formats
Off
DFM_EN0
5-5
*On, but Not Required
DFM_EN1
5-5
On, Required
DFM_EN2
5-5
1
VSAF_1
5-6
2
VSAF_2
5-6
3
VSAF_3
5-6
Secondary Interface Selections
Secondary
Interface
*Disable
2IF_EN0
6-2
Enable
2IF_EN1
6-2
Secondary RS232 Connection
RS-232 Interface
2IFTYP0
6-2
12 - 12
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Secondary
Code 39 Wand
Emulation
Wand Emulation Same Code
Format
2IFTYP64
6-2
Wand Emulation Code 39
Format
2IFTYP61
6-3
Wand Emulation
Multi Block
Delay Between
Blocks
5 ms
WNDDLY0
6-3
*50 ms
WNDDLY1
6-3
150 ms
WNDDLY2
6-3
500 ms
WNDDLY3
6-3
Overall
Checksum
On
WNDCHK1
6-4
*Off
WNDCHK0
6-4
Wand Emulation
Transmission
Rate
10
WNDSPD0
6-4
*25
WNDSPD1
6-4
40
WNDSPD2
6-4
80
WNDSPD3
6-4
120
WNDSPD4
6-4
150
WNDSPD5
6-4
6-4
200
WNDSPD6
Wand Emulation
Polarity
*Black High
WNDPOL0
6-5
White High
WNDPOL1
6-5
Wand Emulation
Idle
*Idle High
WNDIDL1
6-5
Idle Low
WNDIDL0
6-5
Data Block Size
20
WNDBLK0
6-5
*40
WNDBLK1
6-5
60
WNDBLK2
6-5
80
WNDBLK3
6-5
*Manual/Serial Trigger
2IFTRG0
6-6
Read Time-Out
(0 - 300,000 ms) *30,000
TRGSTO####
6-6
Manual Trigger, Low Power
2IFTRG2
6-6
Low Power Time-Out
(0 - 120 seconds) *120
2IFLPT###
6-7
Secondary
Trigger Model
12 - 13
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Hands Free
Time-Out
Range 0 - 300,000 ms
TRGPTO######
6-7
Scan Stand
Scan Stand Mode
2IFTRG4
6-8
Scan Stand Symbol
FNC3
6-8
Presentation
Presentation Mode
2IFTRG3
6-8
All Symbologies Off
ALLENA0
7-2
All Symbologies On
ALLENA1
7-2
Codabar
Default All Codabar
Settings
CBRDFT
7-3
Codabar
Off
CBRENA0
7-3
*On
CBRENA1
7-3
Codabar Start/
Stop Char.
*Don’t Transmit
CBRSSX0
7-3
Transmit
CBRSSX1
7-3
Codabar Check
Char.
*No Check Char.
CBRCK20
7-4
Validate, But Don’t Transmit
CBRCK21
7-4
Validate, and Transmit
CBRCK22
7-4
Codabar
Concatenation
*Off
CBRCCT0
7-4
On
CBRCCT1
7-4
Require
CBRCCT2
7-4
Codabar
Message Length
Minimum (2 - 60) *4
CBRMIN##
7-5
Maximum (2 - 60) *60
CBRMAX##
7-5
Code 39
Default All Code 39
Settings
C39DFT
7-5
Code 39
Off
C39ENA0
7-5
*On
C39ENA1
7-5
*Don’t Transmit
C39SSX0
7-5
Transmit
C39SSX1
7-5
Symbologies
All Symbologies
Code 39 Start/
Stop Char.
12 - 14
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
*No Check Char.
C39CK20
7-6
Validate, But Don’t
Transmit
C39CK21
7-6
Validate,
and Transmit
C39CK22
7-6
Code 39
Message Length
Minimum (0 - 48) *0
C39MIN##
7-6
Maximum (0 - 48) *48
C39MAX##
7-6
Code 39
Append
*Off
C39APP0
7-6
On
C39APP1
7-6
Code 32
Pharmaceutical
(PARAF)
*Off
C39B320
7-7
On
C39B321
7-7
Code 39 Full
ASCII
*Off
C39ASC0
7-8
On
C39ASC1
7-8
Code 39 Code Page
C39DCP
7-8
Interleaved
2 of 5
Default All Interleaved
2 of 5 Settings
I25DFT
7-8
Interleaved
2 of 5
Off
I25ENA0
7-8
*On
I25ENA1
7-8
Interleaved
2 of 5 Check
Digit
*No Check Char.
I25CK20
7-9
Validate, But Don’t
Transmit
I25CK21
7-9
Validate, and Transmit
I25CK22
7-9
Interleaved
2 of 5 Message
Length
Minimum (2 - 80) *4
I25MIN##
7-9
Maximum (2 - 80) *80
I25MAX##
7-9
Code 93
Default All Code 93
Settings
C93DFT
7-10
Code 93
Off
C93ENA0
7-10
*On
C93ENA1
7-11
Minimum (0 - 80) *0
C93MIN##
7-10
Maximum (0 - 80) *80
C93MAX##
7-10
Code 93 Code Page
C93DCP
7-10
Code 39 Check
Char.
Code 93
Message Length
12 - 15
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Straight 2 of 5
Industrial
Default All Straight 2 of 5
Industrial Settings
R25DFT
7-11
Straight 2 of 5
Industrial
*Off
R25ENA0
7-11
On
R25ENA1
7-11
Straight 2 of 5
Industrial
Message Length
Minimum (1 - 48) *4
R25MIN##
7-11
Maximum (1 - 48) *48
R25MAX##
7-11
Straight 2 of 5
IATA
Default All Straight 2 of 5 IATA
Settings
A25DFT
7-12
Straight 2 of 5
IATA
*Off
A25ENA0
7-12
On
A25ENA1
7-12
Straight 2 of 5
IATA Message
Length
Minimum (1 - 48) *4
A25MIN##
7-12
Maximum (1 - 48) *48
A25MAX##
7-12
Matrix 2 of 5
Default All Matrix 2 of 5
Settings
X25DFT
7-13
Matrix 2 of 5
*Off
X25ENA0
7-13
On
X25ENA1
7-13
Matrix 2 of 5
Message Length
Minimum (1 - 80) *4
X25MIN##
7-13
Maximum (1 - 80) *80
X25MAX##
7-13
Code 11
Default All Code 11
Settings
C11DFT
7-13
Code 11
*Off
C11ENA0
7-14
7-14
On
C11ENA1
Code 11 Check
Digits Required
1 Check Digit
C11CK20
7-14
*2 Check Digits
C11CK21
7-14
Code 11
Message Length
Minimum (1 - 80) *4
C11MIN##
7-14
Maximum (1 - 80) *80
C11MAX##
7-14
Code 128
Default All Code 128
Settings
128DFT
7-15
Code 128
Off
128ENA0
7-15
*On
128ENA1
7-15
12 - 16
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
ISBT
Concatenation
*Off
ISBENA0
7-15
On
ISBENA1
7-15
Code 128
Message Length
Minimum (0 - 80) *0
128MIN##
7-16
Maximum (0 - 80) *80
128MAX##
7-16
Code 128 Code
Page
Code 128 Code Page (*2)
128DCP##
7-16
Telepen
Default All Telepen
Settings
TELDFT
7-17
Telepen
*Off
TELENA0
7-17
On
TELENA1
7-17
*AIM Telepen Output
TELOLD0
7-17
Original Telepen Output
TELOLD1
7-17
Telepen
Message Length
Minimum (1 - 60) *1
TELMIN##
7-17
Maximum (1 - 60) *60
TELMAX##
7-17
UPC-A
Default All
UPC-A Settings
UPADFT
7-18
UPC-A
Off
UPAENA0
7-18
*On
UPAENA1
7-18
UPC-A Check
Digit
Off
UPACKX0
7-18
*On
UPACKX1
7-18
UPC-A Number
System
Off
UPANSX0
7-18
*On
UPANSX1
7-18
UPC-A 2 Digit
Addenda
*Off
UPAAD20
7-19
On
UPAAD21
7-19
UPC-A 5 Digit
Addenda
*Off
UPAAD50
7-19
On
UPAAD51
7-19
UPC-A Addenda
Required
*Not Required
UPAARQ0
7-19
Required
UPAARQ1
7-19
UPC-A Addenda
Separator
Off
UPAADS0
7-19
*On
UPAADS1
7-19
Telepen Output
12 - 17
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
UPC-A/EAN-13
with Extended
Coupon Code
*Off
CPNENA0
7-20
Allow Concatenation
CPNENA1
7-20
Require Concatenation
CPNENA2
7-20
UPC-E0
Default All UPC-E
Settings
UPEDFT
7-20
UPC-E0
Off
UPEEN00
7-20
*On
UPEEN01
7-20
*Off
UPEEXP0
7-21
On
UPEEXP1
7-21
UPC-E0
Addenda
Required
Required
UPEARQ1
7-21
*Not Required
UPEARQ0
7-21
UPC-E0
Addenda
Separator
*On
UPEADS1
7-21
Off
UPEADS0
7-21
UPC-E0 Check
Digit
Off
UPECKX0
7-21
*On
UPECKX1
7-21
UPC-E0
Number System
Off
UPENSX0
7-22
*On
UPENSX1
7-22
UPC-E0
Addenda
2 Digit Addenda On
UPEAD21
7-22
*2 Digit Addenda Off
UPEAD20
7-22
5 Digit Addenda On
UPEAD51
7-22
*5 Digit Addenda Off
UPEAD50
7-22
*Off
UPEEN10
7-22
On
UPEEN11
7-22
EAN/JAN-13
Default All EAN/
JAN Settings
E13DFT
7-23
EAN/JAN-13
Off
E13ENA0
7-23
*On
E13ENA1
7-23
Off
E13CKX0
7-23
*On
E13CKX1
7-23
UPC-E0 Expand
UPC-E1
EAN/JAN-13
Check Digit
12 - 18
Selection
EAN/JAN-13 2
Digit Addenda
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
2 Digit Addenda On
E13AD21
7-24
*2 Digit Addenda Off
E13AD20
7-24
5 Digit Addenda On
E13AD51
7-24
7-24
*5 Digit Addenda Off
E13AD50
EAN/JAN-13
Addenda
Required
*Not Required
E13ARQ0
7-24
Required
E13ARQ1
7-24
EAN/JAN-13
Addenda
Separator
Off
E13ADS0
7-24
*On
E13ADS1
7-24
ISBN Translate
*Off
E13ISB0
7-25
7-25
On
E13ISB1
EAN/JAN-8
Default All EAN/
JAN 8 Settings
EA8DFT
7-25
EAN/JAN-8
Off
EA8ENA0
7-25
*On
EA8ENA1
7-25
EAN/JAN-8
Check Digit
Off
EA8CKX0
7-25
*On
EA8CKX1
7-25
EAN/JAN-8
Addenda
*2 Digit Addenda Off
EA8AD20
7-26
2 Digit Addenda On
EA8AD21
7-26
*5 Digit Addenda Off
EA8AD50
7-26
5 Digit Addenda On
EA8AD51
7-26
EAN/JAN-8
Addenda
Required
*Not Required
EA8ARQ0
7-26
Required
EA8ARQ1
7-26
EAN/JAN-8
Addenda
Separator
Off
EA8ADS0
7-26
*On
EA8ADS1
7-26
MSI
Default All MSI Settings
MSIDFT
7-27
MSI
*Off
MSIENA0
7-27
On
MSIENA1
7-27
12 - 19
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
*Validate Type 10, but Don’t
Transmit
MSICHK0
7-27
Validate Type 10 and
Transmit
MSICHK1
7-27
MSI Message
Length
Minimum (4 - 48) *4
MSIMIN##
7-28
Maximum (4 - 48) *48
MSIMAX##
7-28
Plessey Code
Default All Plessey Settings
PLSDFT
7-28
Plessey Code
*Off
PLSENA0
7-28
7-28
MSI Check
Character
On
PLSENA1
Plessey
Message Length
Minimum (4 - 48) *4
PLSMIN##
7-28
Maximum (4 - 48) *48
PLSMAX##
7-28
GS1 DataBar
Omnidirectional
Default All
GS1 DataBar Omnidirectional
Settings
RSSDFT
7-29
GS1 DataBar
Omnidirectional
Off
RSSENA0
7-29
*On
RSSENA1
7-29
GS1 DataBar
Limited
Default All GS1 DataBar
Limited Settings
RSLDFT
7-29
GS1 DataBar
Limited
Off
RSLENA0
7-29
*On
RSLENA1
7-29
GS1 DataBar
Expanded
Default All GS1 DataBar
Expanded Settings
RSEDFT
7-29
GS1 DataBar
Expanded
Off
RSEENA0
7-29
*On
RSEENA1
7-30
GS1 DataBar
Expanded Msg.
Length
Minimum (4 - 74) *4
RSEMIN##
7-30
Maximum (4 - 74) *74
RSEMAX##
7-30
PosiCode
Default All PosiCode Settings
POSDFT
7-32
12 - 20
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Off
POSENA0
7-31
*On
POSENA1
7-31
A and B On
POSLIM0
7-31
A and B and Limited A On
POSLIM1
7-31
*A and B and Limited B On
POSLIM2
7-31
PosiCode Msg.
Length
Minimum (2 - 80) *4
POSMIN##
7-31
Maximum (2 - 80) *48
POSMAX##
7-31
Trioptic Code
*Off
TRIENA0
7-32
On
TRIENA1
7-32
Codablock F
Default All Codablock F
Settings
CBFDFT
7-32
Codablock F
*Off
CBFENA0
7-32
On
CBFENA1
7-32
Minimum (1 - 2048) *1
CBFMIN####
7-32
Maximum (1 - 2048) *2048
CBFMAX####
7-32
Code 16K
Default All Code 16K Settings
16KDFT
7-33
Code 16K
*Off
16KENA0
7-33
PosiCode
Codablock F
Msg. Length
On
16KENA1
7-33
Code 16K Msg.
Length
Minimum (0 - 160) *1
16KMIN###
7-33
Maximum (0 - 160) *160
16KMAX###
7-33
Code 49
Default All Code 49 Settings
C49DFT
7-34
Code 49
Off
C49ENA0
7-34
*On
C49ENA1
7-34
Code 49 Msg.
Length
Minimum (1 - 81) *1
C49MIN##
7-34
Maximum (1 - 81) *81
C49MAX##
7-34
PDF417
Default All PDF417 Settings
PDFDFT
7-35
PDF417
*On
PDFENA1
7-35
Off
PDFENA0
7-35
Minimum (1-2750) *1
PDFMIN
7-35
Maximum (1-2750) *2750
PDFMAX
7-35
PDF417 Msg.
Length
12 - 21
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
MicroPDF417
Default All Micro PDF417
Settings
MPDDFT
7-36
MicroPDF417
On
MPDENA1
7-36
*Off
MPDENA0
7-36
MicroPDF417
Msg. Length
Minimum (1-366) *1
MPDMIN
7-36
Maximum (1-366) *366
MPDMAX
7-36
GS1 Composite
Codes
On
COMENA1
7-36
*Off
COMENA0
7-36
UPC/EAN
Version
On
COMUPC1
7-37
*Off
COMUPC0
7-37
GS1 Composite
Codes Msg.
Length
Minimum (1-2435) *1
COMMIN
7-37
Maximum (1-2435) *2435
COMMAX
7-37
GS1 Emulation
*GS1 Emulation Off
EANEMU0
7-38
GS1-128 Emulation
EANEMU1
7-38
GS1 DataBar Emulation
EANEMU2
7-38
GS1 Code Expansion Off
EANEMU3
7-38
TCIF Linked
Code 39
(TLC39)
On
T39ENA1
7-38
*Off
T39ENA0
7-38
4-CB (4-State
Customer
Barcode)
On
4CBENA1
7-39
*Off
4CBENA0
7-39
ID-tag (UPU 4State)
On
TAGENA1
7-39
*Off
TAGENA0
7-39
Postnet
On
NETENA1
7-39
*Off
NETENA0
7-39
Postnet Check
Digit
Transmit
NETCKX1
7-39
*Don’t Transmit
NETCKX0
7-39
Planet Code
On
PLNENA1
7-39
*Off
PLNENA0
7-40
12 - 22
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Planet Code
Check Digit
Transmit
PLNCKX1
7-40
*Don’t Transmit
PLNCKX0
7-40
British Post
On
BPOENA1
7-41
*Off
BPOENA0
7-41
On
CANENA1
7-40
7-39
Canadian Post
*Off
CANENA0
Kix
(Netherlands)
Post
On
KIXENA1
7-43
*Off
KIXENA0
7-41
Australian Post
On
AUSENA1
7-41
*Off
AUSENA0
7-43
*Bar Output
AUSINT0
7-42
Numeric N Table
AUSINT1
7-42
Alphanumeric C Table
AUSINT2
7-42
On
JAPENA1
7-41
*Off
JAPENA0
7-41
China Post
Default All China Post Settings
CPCDFT
7-43
China Post
*Off
CPCENA0
7-43
7-43
Australian Post
Interpretation
Japanese Post
On
CPCENA1
China Post Msg.
Length
Minimum (2 - 80) *4
CPCMIN##
7-43
Maximum (2 - 80) *80
CPCMAX##
7-43
Korea Post
Default All Korea Post Settings
KPCDFT
7-44
Korea Post
*Off
KPCENA0
7-44
On
KPCENA1
7-44
Korea Post Msg.
Length
Minimum (2 - 80) *4
KPCMIN##
7-44
Maximum (2 - 80) *48
KPCMAX##
7-44
QR Code
Default All QR Code Settings
QRCDFT
7-45
QR Code
*On
QRCENA1
7-45
Off
QRCENA0
7-45
Minimum (1-7089) *1
QRCMIN
7-45
Maximum (1-7089) *7089
QRCMAX
7-45
QR Code Msg.
Length
12 - 23
Selection
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Data Matrix
Default All Data Matrix Settings
IDMDFT
7-46
Data Matrix
*On
IDMENA1
7-46
Off
IDMENA0
7-46
Data Matrix
Msg. Length
Minimum (1-3116) *1
IDMMIN
7-46
Maximum (1-3116) *3116
IDMMAX
7-46
MaxiCode
Default All MaxiCode Settings
MAXDFT
7-47
MaxiCode
*On
MAXENA1
7-47
7-47
Off
MAXENA0
MaxiCode Msg.
Length
Minimum (1-150) *1
MAXMIN
7-47
Maximum (1-150) *150
MAXMAX
7-47
Aztec Code
Default All Aztec Code
Settings
AZTDFT
7-48
Aztec Code
*On
AZTENA1
7-48
Off
AZTENA0
7-48
Aztec Code
Msg. Length
Minimum (1-3832) *1
AZTMIN
7-48
Maximum (1-3832) *3832
AZTMAX
7-48
Aztec Runes
Enable Runes
AZTRUN1
7-48
*Disable Runes
AZTRUN0
7-48
Chinese
Sensible (Han
Xin) Code
On
HX_ENA1
7-49
*Off
HX_ENA0
7-49
Chinese
Sensible (Han
Xin) Code Msg.
Length
Minimum (1-7833) *1
HX_MIN
7-49
Maximum (1-7833) *7833
HX_MAX
7-49
Chinese
Sensible (Han
Xin) Code
Default All Han Xin Code
Settings
HX_DFT
7-49
12 - 24
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry
Page
Imaging Default Commands
Image Snap
Image Ship
Default all Imaging Commands
IMGDFT
8-1
Imaging Style - Decoding
SNPSTY0
8-2
*Imaging Style - Photo
SNPSTY1
8-2
Imaging Style - Manual
SNPSTY2
8-2
Beeper On
SNPBEP1
8-2
*Beeper Off
SNPBEP0
8-2
Exposure (1-7874
microseconds)
SNPEXP
8-3
*Gain - None
SNPGAN1
8-4
Gain - Medium
SNPGAN2
8-4
Gain - Heavy
SNPGAN4
8-4
Gain - Maximum
SNPGAN8
8-4
Delta for Acceptance (0-255)
*25
SNPDEL###
8-4
*LED State - Off
SNPLED0
8-3
LED State - On
SNPLED1
8-3
*Wait for Trigger Off
SNPTRG0
8-2
Wait for Trigger On
SNPTRG1
8-2
Update Tries (0-10) *6
SNPTRY##
8-4
Target White Value (0-255)
*125
SNPWHT###
8-4
Target Set Point Percentage
(1-99) *50
SNPPCT##
8-5
*Infinity Filter - Off
IMGINF0
8-6
Infinity Filter - On
IMGINF1
8-6
*Compensation Off
IMGCOR0
8-6
Compensation On
IMGCOR1
8-6
*Pixel Depth - 8 bits/pixel
(grayscale)
IMGBPP8
8-6
Pixel Depth - 1 bit/pixel (B&W)
IMGBPP1
8-6
*Don’t Sharpen Edges
IMGEDG0
8-7
12 - 25
Selection
Image Ship
(continued)
12 - 26
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Sharpen Edges (0-23)
IMGEDG##
8-7
*File Format - JPEG
IMGFMT6
8-7
File Format - KIM
IMGFMT0
8-7
File Format - TIFF binary
IMGFMT1
8-7
File Format - TIFF binary
group 4, compressed
IMGFMT2
8-7
File Format - TIFF grayscale
IMGFMT3
8-7
File Format - Uncompressed
binary
IMGFMT4
8-7
File Format - Uncompressed
grayscale
IMGFMT5
8-7
File Format - BMP
IMGFMT8
8-7
*Histogram Stretch Off
IMGHIS0
8-8
Histogram Stretch On
IMGHIS1
8-8
Invert Image around X axis
IMGNVX1
8-8
Invert Image around Y axis
IMGNVY1
8-8
*Noise Reduction Off
IMGFSP0
8-9
Noise Reduction On
IMGFSP1
8-9
Image as snapped (rightside
up)
IMGROT0
8-9
Rotate Image 90° right
IMGROT1
8-9
Rotate Image 180° (upside
down)
IMGROT2
8-9
Rotate Image 90° left
IMGROT3
8-9
JPEG Image Quality (0-100)
*50
IMGJQF###
8-10
*Gamma Correction Off
IMGGAM0
8-10
Gamma Correction On (11000)
IMGGAM###
8-10
Image Crop - Left (0-640) *0
IMGWNL###
8-10
Image Crop - Right (0-640)
*639
IMGWNR###
8-10
Selection
Image Ship
(continued)
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
Image Crop - Top (0-480) *0
IMGWNT###
8-10
Image Crop - Bottom (0-480)
*479
IMGWNB###
8-11
Image Crop - Margin (0-238)
*0
IMGMAR###
8-11
Protocol - None (raw)
IMGXFR0
8-11
Protocol - None (default USB)
IMGXFR2
8-11
Protocol - Hmodem
Compressed
IMGXFR3
8-11
Protocol - Hmodem
IMGXFR4
8-11
Ship Every Pixel
IMGSUB1
8-12
Ship Every 2nd Pixel
IMGSUB2
8-12
Ship Every 3rd Pixel
IMGSUB3
8-12
*Document Image Filter Off
IMGUSH0
8-12
Document Image Filter On (0255)
IMGUSH###
8-13
*Don’t Ship Histogram
IMGHST0
8-14
Ship Histogram
IMGHST1
8-14
Default All OCR Settings
OCRDFT
9-1
OCR-A On
OCRENA1
9-1
OCR-B On
OCRENA2
9-2
U.S. Currency On
OCRENA3
9-2
MICR E 13 B On
OCRENA4
9-2
SEMI Font
OCRENA5
9-3
* All OCR Off
OCRENA0
9-3
OCR Selections
OCR
12 - 27
Selection
OCR Check
Character
OCR Templates
12 - 28
Setting
Serial
Command
Page
* Indicates default
# Indicates a
numeric entry
OCR Mod. 10 Check Char.
“OCRCHK01
23456789”
9-8
OCR Mod. 36 Check Char.
“OCRCHK01
23456789AB
CDEFGHIJKL
MNOPQRST
UVWXYZ”
9-8
OCR User-Defined Check
Char.
OCRCHK
9-9
3-1-3-1 Weighted Mod. 10
Check Char.
OCRCHK3-13-1
9-10
2-1-2-1 Weighted Mod. 10
Check Char.
OCRCHK2-12-1
9-10
Enter OCR Template
OCRTMP
9-13
Enter User-Defined Variable g
OCRGPG
9-13
Enter User-Defined Variable h
OCRGPH
9-13
13
Product Specifications
4600g and 4600r
Parameter
Specification
4600g/4600r Dimensions
(Typical):
Height
6.2 inches (15.7 cm)
Length
5.3 inches (13.5 cm)
Width
3.2 inches (8.1 cm)
Weight
6.5 ounces (184.3 g)
4600rp Dimensions (Typical):
Height (Stand and imager)
8.2 inches (20.8 cm)
Length (Stand)
5.4 inches (13.7 cm)
Length (Back edge of stand to
front of imager nose with image
in upright position)
6.5 inches (16.5 cm)
Width (Stand base)
3.5 inches (8.9 cm)
Weight (Stand and imager)
14.9 ounces (422 g)
Illumination:
Scan LEDs
Aiming LEDs
617nm +30nm
526nm +30nm
Image
752x480
Binary, TIFF, or JPEG output.
Skew Angle
±40 degrees
Pitch Angle
±40 degrees
Motion Tolerance:
Streaming Presentation Trigger
Other Trigger Selections
20 inches (50 cm) per second
4 inches (10 cm) per second
Symbol Contrast
Grade 1.0 (20% or greater)
Voltage Requirements
4 - 14 VDC at imager
Current Draw (Typical):
Input
5V
12V
Power Supply Noise Rejection
Maximum 100mV peak to peak, 10 to 100 kHz
Scanning
334mA
170mA
Standby Inrush Low Power
80mA
500mA 100µA
55mA
Temperature Ranges:
Operating
+32°F to +122°F (0°C to +50°C)
Storage
-40°F to +140°F (-40°C to +60°C)
Humidity
0 to 95% non-condensing
Mechanical Drop
Operational after 50 drops from 6 feet
(1.8 m) to concrete
13 - 1
Vibration
Withstands 5G peak from 22 to 300 Hz
ESD Tolerance
15 kV to any external surface
4800i
Parameter
Specification
Dimensions (Typical):
Height
6.2 inches (15.7 cm)
Length
5.3 inches (13.5 cm)
Width
3.2 inches (8.1 cm)
Weight
6.5 ounces (184.3 g)
Illumination:
Scan LEDs
Aiming LEDs
617nm +30nm
526nm +30nm
Image
752x480
Binary, TIFF, or JPEG output.
Skew Angle
±40 degrees
Pitch Angle
±40 degrees
Motion Tolerance:
Streaming Presentation Trigger
Other Trigger Selections
20 inches (50 cm) per second
4 inches (10 cm) per second
Symbol Contrast
Grade 1.0 (20% or greater)
Voltage Requirements
4 - 14 VDC at imager
Current Draw (Typical):
Input
5V
12V
Power Supply Noise Rejection
Maximum 100mV peak to peak, 10 to 100 kHz
Scanning
334mA
170mA
Standby Inrush Low Power
80mA
500mA 100µA
55mA
Temperature Ranges:
Operating
+14°F to +122°F (-10°C to +50°C)
Storage
-40°F to +158°F (-40°C to +70°C)
Humidity
0 to 95% non-condensing
Mechanical Drop
Operational after 50 drops from 6.5 feet
(2 m) to concrete at 10°C
Vibration
Withstands 5G peak from 22 to 300 Hz
ESD Tolerance
15 kV to any external surface
13 - 2
10
2
3
4
5
6
7
8
9
1
Cord shield
Prog 1
Supply ground
Terminal clock
Terminal data
Power connection (Refer to table on page 13-1)
Keyboard data
Keyboard clock
connects to the imager handle
10 Pin RJ41 Modular Plug
Standard Cable Pinouts
Keyboard Wedge
13 - 3
13 - 4
connects to your terminal
9 Pin Type D Female
connects to the imager handle
10 Pin Modular Plug
5 Volt power 9
connection
Cord shield 8
Supply ground 7
6
5
4
3
2
1
Barcode data output
2 Cord shield
3 Tied to 5 Volt power
4 Supply ground
5
6 Barcode data output
7 5 Volt power connection
8
9
10
1
Wand Emulation
2 Cord shield
3 Tied to 5 Volt power
4 Supply ground
5 Receive data - Serial data to imager
6 Transmit data - Serial data from imager
7 5 Volt power connection
8 Request to send data
9 Clear to send data
10
1
connects to the imager handle
10 Pin RJ41 Modular Plug
Serial Output
13 - 5
13 - 6
connects to the imager handle
10 Pin Modular Plug
2 Data +
3 Tied to 5 volt power
4 Supply ground
5
6
7 5 volt power connection
8
9
10 Data -
1
USB
14
Maintenance
Repairs
Repairs and/or upgrades are not to be performed on this product. These services are to be performed only by an authorized service center. See
"Customer Support" on page 15-1 for further information.
Maintenance
Your imager provides reliable and efficient operation with a minimum of care.
Although specific maintenance is not required, the following periodic checks
ensure dependable imager operation:
Cleaning the Device
Reading performance may degrade if the imager’s window is not clean. If the
window is visibly dirty, or if the imager isn’t operating well, clean the window with
a soft cloth or lens tissue dampened with water (or a mild detergent- water
solution). If a detergent solution is used, rinse with a clean lens tissue dampened
with water only.
The imager’s housing may also be cleaned the same way.
!
Caution:
Do not submerge the imager in water. Do not use
abrasive wipes or tissues on the imager’s window –
abrasive wipes may scratch the window.
Never use solvents (e.g., acetone, benzene, ether, or
phenol-based agents) on the housing or window –
solvents may damage the finish or the window.
Inspecting Cords and Connectors
Inspect the imager’s interface cable and connector for wear or other signs of
damage. A badly worn cable or damaged connector may interfere with imager
operation. Contact your Honeywell distributor for information about cable
replacement. Cable replacement instructions are on page 14-2.
14 - 1
Replacing the Interface Cable
The standard interface cable is attached to the imager with an 10-pin modular
connector. When properly seated, the connector is held in the imager’s handle
by a flexible retention tab. The interface cable is designed to be field
replaceable.
• Order replacement cables from Honeywell or from an authorized distributor.
• When ordering a replacement cable, specify the cable part number of the
original interface cable.
To Replace the 4600g/4600r Interface Cable:
1. Turn the power to the host system
OFF.
2. Disconnect the imager’s cable from
the terminal or computer.
3. Locate the small hole on the side of
the imager’s handle. This is the cable
release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the
small hole and press in. This
depresses the retention tab, releasing
the connector. Pull the connector out
while maintaining pressure on the
paper clip, then remove the paper clip.
6. Replace with the new cable.
Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will click into place.
14 - 2
Cable
Release
To Replace the 4600rp Interface Cable:
1. Turn the power to the host system
OFF.
2. Disconnect the imager’s cable from
the terminal or computer.
3. Rotate the imager downward to the
last position.
4. Locate the small hole on the side of
the stand. This is the cable release.
5. Straighten one end of a paper clip.
Cable
Release
6. Insert the end of the paper clip into the
small hole and press in. This
depresses the retention tab, releasing the connector. Pull the connector out
while maintaining pressure on the paper clip, then remove the paper clip.
7. Replace with the new cable.
Insert the connector into the opening and press firmly. The connector is
keyed to go in only one way, and will click into place.
To Replace the 4800i Interface Cable:
1. Turn the power to the host system
OFF.
2. Disconnect the imager’s cable from
the terminal or computer.
3. Use a screwdriver to unscrew the cord
lock from the base of the imager.
4. Locate the small hole on the side of
the imager’s handle. This is the cable
release.
5. Straighten one end of a paper clip.
6. Insert the end of the paper clip into the
small hole and press in. This
depresses the retention tab, releasing
the connector. Pull the connector out
while maintaining pressure on the
paper clip, then remove the paper clip.
Cable
Release
Cord lock
7. Replace with the new cable.
Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will click into place.
14 - 3
8. Screw the cord lock back in place over the cord.
Troubleshooting
The imager automatically performs self-tests whenever you turn it on. If your
imager is not functioning properly, review the following Troubleshooting Guide to
try to isolate the problem.
Is the power on? Is the aiming beam on?
If the aiming beam isn’t illuminated, check that:
• The cable is connected properly.
• The host system power is on (if external power isn’t used).
• The trigger works.
Is the imager having trouble reading your symbols?
If the imager isn’t reading symbols well, check that the symbols:
• Aren’t smeared, rough, scratched, or exhibiting voids.
• Aren’t coated with frost or water droplets on the surface.
• Are enabled in the imager or in the decoder to which the imager connects.
Is the barcode displayed but not entered?
The barcode is displayed on the host device correctly, but you still have to press
a key to enter it (the Enter/Return key or the Tab key, for example).
You need to program a suffix. Programming a suffix enables the imager to
output the barcode data plus the key you need (such as “CR”) to enter the data
into your application. Refer to "Prefix/Suffix Overview" on page 4-1 for further
information.
Does the imager read the barcode incorrectly?
If the imager reads a barcode, but the data is not displayed correctly on the host
screen:
• The imager may not be programmed for the appropriate terminal interface.
For example, you scan “12345” and the host displays “@es%.”
Reprogram the imager with the correct Plug and Play or Terminal selection
barcode. See Chapter 1 and Chapter 2.
• The imager may not be programmed to output your barcode data properly.
For example, you scan “12345” and the host displays “A12345B.”
Reprogram the imager with the proper symbology selections. See Chapter 7.
The imager won’t read your barcode at all.
14 - 4
1. Scan the sample barcodes in the back of this manual. If the imager reads
the sample barcodes, check that your barcode is readable.
Verify that your barcode symbology is enabled (see Chapter 7).
2. If the imager still can’t read the sample barcodes, scan "All Symbologies" on
page 7-2.
If you aren’t sure what programming options have been set in the imager, or if
you want the factory default settings restored, scan Standard Product Default
Settings on page 12-4.
14 - 5
14 - 6
15
Customer Support
Technical Assistance
If you need assistance installing or troubleshooting your device, please call your
distributor or the nearest technical support office:
North America/Canada
Telephone: (800) 782-4263
Fax number: (315) 554-6705
E-mail: [email protected]
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
E-mail: [email protected]
Brazil
Telephone: +55 (21) 3535-9100
Fax: +55 (21) 3535-9105
E-mail: [email protected]
Mexico
Telephone: (803) 835-8000
E-mail: [email protected]
Europe, Middle East, and Africa
Telephone: +31 (0) 40 7999 393
Fax: +31 (0) 40 2425 672
E-mail: [email protected]
Asia Pacific
Telephone - Hong Kong: +852-3188-3485 or 2511-3050
Telephone - China: +86 21 6361 3818
E-mail: [email protected]
Japan
Telephone: +813-3839-8511
E-mail: [email protected]
Malaysia
Telephone: +603-6201-7020
E-mail: [email protected]
Online Technical Assistance
You can also access technical assistance online at www.honeywell.com/aidc.
15 - 1
Product Service and Repair
Honeywell International Inc. provides service for all its products through service
centers throughout the world. To obtain warranty or non-warranty service,
contact the appropriate location below to obtain a Return Material Authorization
number (RMA #) before returning the product.
North America
Telephone: (800) 782-4263
Fax: (803) 835-8012
E-mail: [email protected]
Latin America
Telephone: (803) 835-8000
Telephone: (800) 782-4263
Fax: (239) 263-9689
E-mail: [email protected]
Brazil
Telephone: +55 (21) 3535-9100
Fax: +55 (21) 3535-9105
E-mail: [email protected]
Mexico
Telephone: +52 (55) 5203-2100
Fax: +52 (55) 5531-3672
E-mail: [email protected]
Europe, Middle East, and Africa
Telephone:
+31 (0) 40 2901 633
Fax: +31 (0) 40 2901 631
E-mail: [email protected]
Asia Pacific
Telephone: +852-2511-3050
Fax: +852-2511-3557
E-mail: [email protected]
Japan
Telephone: +813-3839-8511
Fax: +813-3839-8519
E-mail: [email protected]
Online Product Service and Repair Assistance
You can also access product service and repair assistance online at
www.honeywell.com/aidc.
15 - 2
Limited Warranty
Honeywell International Inc. ("HII") warrants its products to be free from defects
in materials and workmanship and to conform to HII’s published specifications
applicable to the products purchased at the time of shipment. This warranty
does not cover any HII product which is (i) improperly installed or used; (ii) damaged by accident or negligence, including failure to follow the proper maintenance, service, and cleaning schedule; or (iii) damaged as a result of (A)
modification or alteration by the purchaser or other party, (B) excessive voltage
or current supplied to or drawn from the interface connections, (C) static electricity or electro-static discharge, (D) operation under conditions beyond the
specified operating parameters, or (E) repair or service of the product by anyone other than HII or its authorized representatives.
This warranty shall extend from the time of shipment for the duration published
by HII for the product at the time of purchase ("Warranty Period"). Any defective
product must be returned (at purchaser’s expense) during the Warranty Period
to HII factory or authorized service center for inspection. No product will be
accepted by HII without a Return Materials Authorization, which may be
obtained by contacting HII. In the event that the product is returned to HII or its
authorized service center within the Warranty Period and HII determines to its
satisfaction that the product is defective due to defects in materials or workmanship, HII, at its sole option, will either repair or replace the product without
charge, except for return shipping to HII.
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE
FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR
WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN,
INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
HII’S RESPONSIBILITY AND PURCHASER’S EXCLUSIVE REMEDY UNDER
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF THE
DEFECTIVE PRODUCT WITH NEW OR REFURBISHED PARTS. IN NO
EVENT SHALL HII BE LIABLE FOR INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY OF HII
ARISING IN CONNECTION WITH ANY PRODUCT SOLD HEREUNDER
(WHETHER SUCH LIABILITY ARISES FROM A CLAIM BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED THE ACTUAL
AMOUNT PAID TO HII FOR THE PRODUCT. THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND EFFECT EVEN WHEN HII MAY
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH INJURIES, LOSSES,
OR DAMAGES. SOME STATES, PROVINCES, OR COUNTRIES DO NOT
ALLOW THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY
NOT APPLY TO YOU.
All provisions of this Limited Warranty are separate and severable, which means
that if any provision is held invalid and unenforceable, such determination shall
not affect the validity of enforceability of the other provisions hereof. Use of any
peripherals not provided by the manufacturer may result in damage not covered
by this warranty. This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first endusers of the products. These warranties are non-transferable.
15 - 3
The duration of the limited warranty for the 4600g, 4600r, 4600rp, or 4800i is for
five (5) year(s).
15 - 4
A
Reference Charts
Symbology Chart
Symbology
AIM ID
Possible AIM
ID Modifiers
( m)
All Symbologies
Code ID
(hex)
(0x99)
Australian Post
]X0
Aztec Code
]zm
A (0x41)
0-9, A-C
z (0x7A)
British Post
]X0
B (0x42)
Canadian Post
]X0
C (0x43)
China Post
]X0
Q (0x51)
Chinese Sensible Code (Han Xin
Code)
]X0
H (0x48)
Codabar
]Fm
0-1
Codablock F
]Om
0, 1, 4, 5, 6
Code 11
]H3
Code 128
]Cm
0, 1, 2, 4
Code 16K
]Km
0, 1, 2, 4
Code 32 Pharmaceutical (PARAF)
]X0
Code 39 (supports Full ASCII mode)
]Am
0, 1, 3, 4, 5, 7
b (0x62)
Code 49
]Tm
0, 1, 2, 4
l (0x6C)
Code 93 and 93i
]Gm
0-9, A-Z,
a-m
i (0x69)
Data Matrix
]dm
0-6
w (0x77)
a (0x61)
q (0x71)
h (0x68)
j (0x6A)
o (0x6F)
< (0x3C)
EAN-13 (including Bookland EAN)
]E0
d (0x64)
EAN-13 with Add-On
]E3
d (0x64)
EAN-13 with Extended Coupon Code
]E3
d (0x64)
EAN-8
]E4
D (0x44)
EAN-8 with Add-On
]E3
GS1 Composite
]em
0-3
y (0x79)
GS1 DataBar
]em
0
y (0x79)
D (0x44)
GS1-128
]C1
I (0x49)
ID-tag (UPU 4-State)
]X0
N (0x4E)
A-1
Symbology
AIM ID
Possible AIM
ID Modifiers
( m)
Code ID
(hex)
Intelligent Mail Barcode
]X0
M (0x4D)
Interleaved 2 of 5
]Im
Japanese Post
]X0
J (0x4A)
KIX (Netherlands) Post
]X0
K (0x4B)
Korea Post
]X0
? (0x3F)
0, 1, 3
e (0x65)
Matrix 2 of 5
]X0
MaxiCode
]Um
0-3
m (0x6D)
x (0x7 8)
MicroPDF417
]Lm
3-5
R (0x52)
MSI
]Mm
0
OCR MICR (E 13 B)
]o3
g (0x67)
O (0x4F)
OCR SEMI Font
]o3
O (0x4F)
OCR US Money Font
]o3
O (0x4F)
OCR-A
]o1
O (0x4F)
OCR-B
]o2
O (0x4F)
PDF417
]Lm
0-2
r (0x72)
Planet Code
]X0
L (0x4C)
Plessey Code
]P0
n (0x6E)
Postnet
]X0
QR Code and Micro QR Code
]Qm
0-6
s (0x73)
Straight 2 of 5 IATA
]Rm
0, 1, 3
f (0x66)
Straight 2 of 5 Industrial
]S0
f (0x66)
TCIF Linked Code 39 (TLC39)
]L2
T (0x54)
UPC-A
]E0
c (0x63)
]E3
c (0x63)
UPC-A with Add-On
UPC-A with Extended Coupon Code
UPC-E
P (0x50)
]E3
c (0x63)
]E0
E (0x45)
UPC-E with Add-On
]E3
E (0x45)
UPC-E1 (obsolete)
]X0
E (0x45)
A-2
Note: “m” represents the AIM modifier character. Refer to International
Technical Specification, Symbology Identifiers, for AIM modifier character
details.
Note: Prefix/Suffix entries for specific symbologies override the universal (All
Symbologies, 99) entry.
Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on
page 5-1 for information about using Code ID and AIM ID.
A-3
ASCII Conversion Chart (Code Page 1252)
Note:
This table applies to U.S. style keyboards. Certain characters may differ depending on your
Country Code/PC regional settings.
Dec Hex Char
Dec
Hex
Char Dec
Hex
Char Dec
Hex Char
0
00
NUL
32
20
64
40
@
96
60
‘
1
01
SOH
33
21
!
65
41
A
97
61
a
2
02
STX
34
22
“
66
42
B
98
62
b
3
03
ETX
35
23
#
67
43
C
99
63
c
4
04
EOT
36
24
$
68
44
D
100
64
d
5
05
ENQ
37
25
%
69
45
E
101
65
e
6
06
ACK
38
26
&
70
46
F
102
66
f
7
07
BEL
39
27
‘
71
47
G
103
67
g
8
08
BS
40
28
(
72
48
H
104
68
h
9
09
HT
41
29
)
73
49
l
105
69
i
10
0A
LF
42
2A
*
74
4A
J
106
6A
j
11
0B
VT
43
2B
+
75
4B
K
107
6B
k
12
0C
FF
44
2C
,
76
4C
L
108
6C
l
13
0D
CR
45
2D
-
77
4D
M
109
6D
m
14
0E
SO
46
2E
.
78
4E
N
110
6E
n
15
0F
SI
47
2F
/
79
4F
O
111
6F
o
16
10
DLE
48
30
0
80
50
P
112
70
p
17
11
DC1
49
31
1
81
51
Q
113
71
q
18
12
DC2
50
32
2
82
52
R
114
72
r
19
13
DC3
51
33
3
83
53
S
115
73
s
20
14
DC4
52
34
4
84
54
T
116
74
t
21
15
NAK
53
35
5
85
55
U
117
75
u
22
16
SYN
54
36
6
86
56
V
118
76
v
23
17
ETB
55
37
7
87
57
W
119
77
w
24
18
CAN
56
38
8
88
58
X
120
78
x
25
19
EM
57
39
9
89
59
Y
121
79
y
26
1A
SUB
58
3A
:
90
5A
Z
122
7A
z
27
1B
ESC
59
3B
;
91
5B
[
123
7B
{
28
1C
FS
60
3C
<
92
5C
\
124
7C
|
29
1D
GS
61
3D
=
93
5D
]
125
7D
}
30
1E
RS
62
3E
>
94
5E
^
126
7E
~
31
1F
US
63
3F
?
95
5F
_
127
7F
A-4
Dec
Hex
Char
Dec
Hex
Char Dec
Hex
160
A0
192
C0
À
224
E0
à
161
A1
¡
193
C1
Á
225
E1
á
162
A2
¢
194
C2
Â
226
E2
â
ƒ
163
A3
£
195
C3
Ã
227
E3
ã
84
„
164
A4
¤
196
C4
Ä
228
E4
ä
85
…
165
A5
¥
197
C5
Å
229
E5
å
134
86
†
166
A6
¦
198
C6
Æ
230
E6
æ
135
87
‡
167
A7
§
199
C7
Ç
231
E7
ç
136
88
ˆ
168
A8
¨
200
C8
È
232
E8
è
137
89
‰
169
A9
©
201
C9
É
233
E9
é
138
8A
Š
170
AA
ª
202
CA
Ê
234
EA
ê
139
8B
‹
171
AB
«
203
CB
Ë
235
EB
ë
140
8C
Œ
172
AC
¬
204
CC
Ì
236
EC
ì
141
8D
173
AD
-
205
CD
Í
237
ED
í
142
8E
174
AE
®
206
CE
Î
238
EE
î
143
8F
175
AF
¯
207
CF
Ï
239
EF
ï
144
90
176
B0
°
208
D0
Ð
240
F0
ð
145
91
‘
177
B1
±
209
D1
Ñ
241
F1
ñ
146
92
’
178
B2
²
210
D2
Ò
242
F2
ò
147
93
“
179
B3
³
211
D3
Ó
243
F3
ó
148
94
”
180
B4
´
212
D4
Ô
244
F4
ô
149
95
•
181
B5
µ
213
D5
Õ
245
F5
õ
150
96
–
182
B6
¶
214
D6
Ö
246
F6
ö
151
97
—
183
B7
·
215
D7
×
247
F7
÷
152
98
˜
184
B8
¸
216
D8
Ø
248
F8
ø
153
99
™
185
B9
¹
217
D9
Ù
249
F9
ù
154
9A
š
186
BA
218
DA
Ú
250
FA
ú
155
9B
›
187
BB
»
219
DB
Û
251
FB
û
156
9C
œ
188
BC
¼
220
DC
Ü
252
FC
ü
157
9D
189
BD
½
221
DD
Ý
253
FD
ý
158
9E
ž
190
BE
¾
222
DE
Þ
254
FE
þ
159
9F
Ÿ
191
BF
¿
223
DF
ß
255
FF
ÿ
€€
128
80
129
81
130
82
‚
131
83
132
133
Ž
Char Dec
Hex
Char
A-5
Code Page Mapping of Printed Barcodes
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the
barcode being scanned was created using a code page that is different from
the one the host program is expecting. If this is the case, select the code page
with which the barcodes were created. The data characters should then appear
properly.
Note: The Code Page option is available for Code 39, Code 93, and Code 128.
Code Page
Standard
1
CP ISO646
2 (Default)
ISO 2022
3
CP Binary
82
ISO 2022 11 Swe
Swedish Replacement Characters
83
ISO 2022 69 Fra
French/Belgian Replacement Characters
81
ISO 2022 25 Fra
French/Belgian Replacement Characters
84
ISO 2022 11 Ger
German Replacement Characters
85
ISO 2022 11 Ita
Italian Replacement Characters
86
ISO 2022 11 Swi
Swiss Replacement Characters
87
ISO 2022 11 UK
British Replacement Characters
88
ISO 2022 11 Dan
Danish Replacement Characters
89
ISO 2022 11 Nor
Norwegian Replacement Characters
90
ISO 2022 11 Spa
Spanish Replacement Characters
A-6
Description
Automatic National Replacement Characters
Sample Symbols
UPC-A
0 123456 7890
Code 128
Code 128
Code 39
BC321
Code 93
123456-9$
Interleaved 2 of 5
1234567890
EAN-13
9 780330 290951
Codabar
A13579B
Straight 2 of 5 Industrial
123456
Sample Symbols
Matrix 2 of 5
GS1 DataBar
6543210
PDF417
(01)00123456789012
Postnet
Car Registration
Zip Code
Code 49
1234567890
Data Matrix
QR Code
Test Symbol
Numbers
4-CB (4-State Customer Barcode)
01,234,567094,987654321,01234567891
ID-tag (UPU 4-State)
J18CUSA8E6N062315014880T
Sample Symbols
Aztec
Micro PDF417
Package Label
MaxiCode
Test Message
OCR-A with Modulo 36
check character
Test Message
OCR-B with Modulo 10
check character
OCR Programming Chart
a
c
d
e
g
h
l
r
t
OCR Programming Chart
T
O
A
D
Discard
Save
Programming Chart
A
B
C
D
E
F
0
1
2
3
Programming Chart
4
5
6
7
8
9
Save
Discard
Note: If you make an error while scanning the letters or digits (before scanning
Save), scan Discard, scan the correct letters or digits, and Save again.
Honeywell
700 Visions Drive
P.O. Box 208
Skaneateles Falls, NY 13153-0208
46gr-48i-UG Rev F