Equipment Detail
Accuracy (Photometric): 1A: ±0.006A 2A: ±0.010A;Measured at 440nm using
calibrated neutral density filters traceable to NIST
Baseline Flatness :±0.0010A, 200800nm, 1.0nm SBW, smoothing
Beam Geometry: Doublebeam with Application Focused Beam Geometry
Certifications/Compliance: ISO 9001:2008
Data Interval: 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm
Description: Evolution 260 Bio Local Control Spectrophotometer
Detector Type: Dual Silicon Photodiodes
Dimensions (L x W x H): 62.2 x 48.6 x 27.9 cm
Display: Touchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal)
Drift: <0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warmup
Electrical Requirements: 100240 V 5060 Hz selected automatically 150W
maximum
Item Description: Evolution 260 LC Spectrophotometer
Keypad: Sealed membrane
Lamp: Xenon Flash Lamp, 3year warranty (7 years typical lifetime)
Noise: 0A: <0.00015A, 1A: <0.00025A, 2A: <0.00080A, 260nm, 1.0nm SBW, RMS
Operating System: Microsoft Windows™ XP embedded INSIGHT 2 Software is
also compatible with Windows 7 and Windows 8.1 Professional Editions and can be
installed on a computer attached to the instrument
Optical Design: Double Beam with sample and reference cuvette positions;
Application Focused Beam Geometry; CzernyTurner Monochromator
Pharmacopoeia Compliance Testing: (Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7):
±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Accuracy Instrument: 1A: ±0.006A 2A: ±0.010A Measured at 440nm
using calibrated neutral density filters traceable to NIST
Photometric Display: 0.3, 4.0A
Photometric Range: >3.5A
Photometric Repeatability: ±0.0002A
Range (Photometric): N/A
Resolution (Toluene/Hexane): N/A
Scan Ordinate Modes: Absorbance, % Transmittance, % Reflectance,
KubelkaMunk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed: <16000nm/ min, variable
Spectral Bandwidth: Variable 1.0nm; 2.0nm; AFBG microcell optimized; AFBG
fiber optic optimized; AFBG materials optimized
Stray Light: N/A
Type: Evolution 260 Bio Computer Control Spectrophotometer- Thermo Scientific
Qnt. Amount
01
Wavelength Accuracy: ±0.5nm (541.9, 546.1nm mercury lines)
±0.8nm (full range 1901100nm)
Wavelength Range: 190 1,100nm
Wavelength Scan Speed: <1 to 6,000 nm/min; variable
Wavelength Slew Speed: N/A
Weight (Metric): 14.4 kg
Optional Accessory:
Digital Peltier Temp Controller with Rectangular Cell Holder & Stir to be quoted.
Accessory:
Two Pairs of Glass & Quartz cuvettes
Extra Accessories: (1) 2-3 hours Battery back-up UPS system (Branded)
(2) UV-Visible Spectrophotometer Protecting Acrylic Lock
and Key Safety Cabinet.
Price in words The above rates are including all Taxes, carting, Labour charges,
Packaging, & Freight. There is no other extra charges on above mentioned rates.
I/We am/ I agree with Terms and condition attached with tender Form.
Signature of the tenderer/agency
Name of the tenderer/agency
Place:
Date:
Seal of the tenderer/agency