GUJARAT VIDYAPITH ASHRAM ROAD, AHMEDABAD – 380014 PhoneNo : 40016200/ 27540746 Fax No : 27542547 Website : www. Gujaratvidyapith.org Sr. No of Tender : GV/1/2015-16 FINANCIAL BID No. 1 Equipment Detail Accuracy (Photometric): 1A: ±0.006A 2A: ±0.010A;Measured at 440nm using calibrated neutral density filters traceable to NIST Baseline Flatness :±0.0010A, 200800nm, 1.0nm SBW, smoothing Beam Geometry: Doublebeam with Application Focused Beam Geometry Certifications/Compliance: ISO 9001:2008 Data Interval: 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm Description: Evolution 260 Bio Local Control Spectrophotometer Detector Type: Dual Silicon Photodiodes Dimensions (L x W x H): 62.2 x 48.6 x 27.9 cm Display: Touchscreen LCD panel; 800 x 480; 17.8 cm (7 in. diagonal) Drift: <0.0005 A/hr, 500 nm, 1.0nm SBW, 1 hr warmup Electrical Requirements: 100240 V 5060 Hz selected automatically 150W maximum Item Description: Evolution 260 LC Spectrophotometer Keypad: Sealed membrane Lamp: Xenon Flash Lamp, 3year warranty (7 years typical lifetime) Noise: 0A: <0.00015A, 1A: <0.00025A, 2A: <0.00080A, 260nm, 1.0nm SBW, RMS Operating System: Microsoft Windows™ XP embedded INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument Optical Design: Double Beam with sample and reference cuvette positions; Application Focused Beam Geometry; CzernyTurner Monochromator Pharmacopoeia Compliance Testing: (Guaranteed Performance Specifications) Resolution (toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line Photometric Accuracy Instrument: 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral density filters traceable to NIST Photometric Display: 0.3, 4.0A Photometric Range: >3.5A Photometric Repeatability: ±0.0002A Range (Photometric): N/A Resolution (Toluene/Hexane): N/A Scan Ordinate Modes: Absorbance, % Transmittance, % Reflectance, KubelkaMunk, log (1/R), log (Abs), Abs*Factor, Intensity Scan Speed: <16000nm/ min, variable Spectral Bandwidth: Variable 1.0nm; 2.0nm; AFBG microcell optimized; AFBG fiber optic optimized; AFBG materials optimized Stray Light: N/A Type: Evolution 260 Bio Computer Control Spectrophotometer- Thermo Scientific Qnt. Amount 01 Wavelength Accuracy: ±0.5nm (541.9, 546.1nm mercury lines) ±0.8nm (full range 1901100nm) Wavelength Range: 190 1,100nm Wavelength Scan Speed: <1 to 6,000 nm/min; variable Wavelength Slew Speed: N/A Weight (Metric): 14.4 kg Optional Accessory: Digital Peltier Temp Controller with Rectangular Cell Holder & Stir to be quoted. Accessory: Two Pairs of Glass & Quartz cuvettes Extra Accessories: (1) 2-3 hours Battery back-up UPS system (Branded) (2) UV-Visible Spectrophotometer Protecting Acrylic Lock and Key Safety Cabinet. Price in words The above rates are including all Taxes, carting, Labour charges, Packaging, & Freight. There is no other extra charges on above mentioned rates. I/We am/ I agree with Terms and condition attached with tender Form. Signature of the tenderer/agency Name of the tenderer/agency Place: Date: Seal of the tenderer/agency
© Copyright 2024