Use of Geothermal resources for district heating a 35-years experience in the Paris Basin the « doublet » technology for District Heating Shallow DOGGER – 2000 meters deep Heating and Cooling in the European Energy Transition History and Objectives 55 doublets implemented between 1975 to 1986 34 in operation for more than 30 years Abandoned after 1986 For Deep geothermal, National Renewable Energy Action Plan consider increase from 155 ktoe in 2006 to 500 ktoe in 2020. = X 3 in Paris Basin Heating and Cooling in the European Energy Transition 3 Crucial parameters for a project success temperature geology flow rate investment financial costs investment/ finance Géothermal & Power project plant availability Technical network multipurpose conception geothermal power optimisation (MW) sales volume connection density marketing (starting) heat price price development competition Heating and Cooling in the European Energy Transition Industrial Heat pumps heating project reservoir temperature Domestic Hot Water production > at 60°C Heating and Cooling in the European Energy Transition 5 Heat pumps for geothermal district heating The benefict of a heat pump : Increase the temperature level of the geothermal water to the level of the district heating distribution temperature, Extract as much heat energy as possible from geothermal water before it is injected back into the reservoir, Produce or increase renewable cooling … For the project availability : Production of domestic hot water on base load when geothermal ressouce is < 60°C , Increase the geothermal energy (MWh ) in the heat production with reduce marginal investment (compare to the wells), Increase and stabilize the geothermal power (MW) in all the heat season, Increase the potential of geothermal district heating projets in Paris Basin, France and Europe ! Heating and Cooling in the European Energy Transition 6 Since 2008 more than 20 GeoDH revamping with new wells and 3 new opérations. For 2014 -2015, 6 new GeoDH Heating and Cooling in the European Energy Transition 7 The Exemple of Paris (18éme) The plant draws geothermal heat from the reservoir at a depth of 1,600 meters and a temperature of 55°C. The geothermal energy is recovered using heat pumps (10 MW) that are able to simultaneously produce renewable thermal energy for both heating and cooling, Exemple of Arcueil Gentilly A Geothermal Doublet at 1600 metres deep and 62°C completed by: 6 MW Screw Heat Pump, 6MW Centrifugal Heat pump. Total : 48 MW Geothermal and Gas for 100 GWh of heat Heating and Cooling in the European Energy Transition 9
© Copyright 2024