Liquid Crystal Polymer Substrates to Enable Advanced RF and Medical Applications Susan Bagen & Brian Sinclair – MST Inc. Eckardt Bihler, Marc Hauer & Daniel Schulze – DYCONEX AG New England 42nd Symposium & Expo LCP – LIQUID CRYSTAL POLYMER - PROPERTIES SIGNAL ATTENUATION Very flexible thermoplastic 5 4.5 High temperature stability 4 (Tg > 280°C, Td > 320°C) Near-hermetic 3.5 Attenuation dB Very low water absorption (0.04 %) Si** 3 GaAS** 2.5 2 LCP* 1.5 Excellent high frequency properties (εR= 2.9, tan θ = 0.0025) Light weight (1.4 g/cm3) 1 0.5 0 0 20 40 60 80 100 120 Frequency GHz *D. Thompson, et al.,“W-Band Characterization of Finite Ground Coplanar Transmission Lines on Liquid Crystal Polymer (LCP) Substrates”, IEEE ECTC 2003. ** Fred Brauchler, Ph.D. Dissertation, The University of Michigan, Ann Arbor, MI. New England 42nd Symposium & Expo © DYCONEX AG May 2015 2 COMPARISON of MATERIALS Material Property LCP PTFE / Glass Rogers Ultralam 3000 Rogers RT/duroid 5880 Hydrocarbon / Ceramic PTFE / Ceramic Rogers RO3003 Different Suppliers Rogers RO4350B LTCC Dielectric constant @ 10 GHz 2.9 2.2 3.66 3.00 7.4 – 7.8* Dissipation factor @ 10 GHz 0.0025 0.0009 0.0037 0.0013 0.001 Water absorption % 0.04 0.9 0.06 < 0.1 < 0.05 CTE X ppm/°C 17 31 14 17 6 – 10* CTE Y ppm/°C 17 48 16 17 6 – 10* CTE Z ppm/°C 150 237 35 24 6 – 10* Density g/cm3 1.4 2.2 1.86 2.1 3.2 Thermal conductivity W/m°K 0.2 0.22 --- 0.65 2.8 – 4.9* * Values vary depending on LTCC type used New England 42nd Symposium & Expo © DYCONEX AG May 2015 3 PROCESS PROPERTIES – LCP vs. LTCC LCP PCB processes produce improved conductor structures with reduced skin effect losses at high frequencies. Edge profile nearperpendicular and better defined. LCP Copper etched conductor profile LTCC printed conductor profile Conductor edge roughness reduced. 65µm traces on LTCC New England 42nd Symposium & Expo 60µm traces on LCP © DYCONEX AG May 2015 4 LCP FREQUENCY – UP TO 110 GHz LCP has stable dielectric constant over a very wide frequency range. Effective Dielectric Constant 3.5 3 2.5 2 1.5 LCP 1 Multilayer structures have homogeneous LCP dielectric throughout cross-section. 0 -0.5 0 20 40 60 80 100 120 Frequency (GHz) Source: IEEE ECTC 2003 “W-Band Characterization of Finite Ground Coplanar Transmission Lines on Liquid Crystal Polymer (LCP) Substrates”, Dane Thompson*, Pete Kirby, John Papapolymerou, Manos M. Tentzeris, Georgia Institute of Technology New England 42nd Symposium & Expo © DYCONEX AG May 2015 5 LCP vs. CONVENTIONAL PCB MATERIALS Dielectric Constant Variation with Moisture LCP, Polyimide, and FR-4 Laminates 4.8 4.5 Dielectric Constant 4.3 FR-4: 50°C Immersion 4.0 FR-4: 23°C, 50%RH 3.8 PI: 50°C Immersion 3.5 PI: 23°C, 50%RH LCP: 50°C Immersion 3.3 LCP: 23°C, 50%RH 3.0 2.8 2.5 0 2 4 6 8 10 12 LCP dielectric constant remains stable upon exposure to moisture. Frequency, GHz New England 42nd Symposium & Expo © DYCONEX AG May 2015 6 LCP vs. CONVENTIONAL PCB MATERIALS Dissipation Factor Variation with Moisture LCP, Polyimide, and FR-4 Laminates 0.040 Dissipation Factor 0.035 FR-4: 50°C Immersion 0.030 FR-4: 23°C, 50%RH 0.025 PI: 50°C Immersion 0.020 PI: 23°C, 50%RH 0.015 LCP: 50°C Immersion 0.010 LCP: 23°C, 50%RH 0.005 0.000 0 2 4 6 8 10 12 LCP dissipation factor remains stable upon exposure to moisture. Frequency, GHz New England 42nd Symposium & Expo © DYCONEX AG May 2015 7 LCP SUBSTRATE FABRICATION FEATURES Cavity structures for die placement and patch antenna Flexible antennas, connectors & electrodes Source: D.L. Paul, et al., “Flexible Dual Band LCP Antenna for RFID Applications”, Proceedings of the 2013 International Symposium on Electromagnetic Theory, pp. 973-976. New England 42nd Symposium & Expo © DYCONEX AG May 2015 8 LCP SUBSTRATE FABRICATION FEATURES Wirebondable cavity ledge to access inner layers without lossy vias Air bridges New England 42nd Symposium & Expo © DYCONEX AG May 2015 9 LCP SUBSTRATE WITH HEATSINK BASE • High power density application • Direct bonding to heat sink • Operating temperature up to 150°C • Gold wire bondable surface: ENEPIG • Buried RF tracks under lid mounting • Lids mounted to circuit to seal cavities Metal Lid Cavity 50 µm LCP 50 µm Bondply 100 µm LCP Die LCP Aluminum Plate New England 42nd Symposium & Expo © DYCONEX AG May 2015 10 HF LCP BGA PACKAGE • Laser blind vias 50 or 75 µm • Laser vias through 3 layers 75 or 100 µm • Line / Space: > 25 / 25 µm • Lid sealing for near-hermetic package Metal Lid Cavity 50 µm LCP 50 µm Bondply 100 µm LCP Die LCP Soldermask 20 µm BGA New England 42nd Symposium & Expo © DYCONEX AG May 2015 11 BIOCOMPATIBLE SUBSTRATES New biocompatible metal layers New market fields Smaller feature sizes Biocompatible PCBs Large panel format Manufacturing know how Long term stability New England 42nd Symposium & Expo © DYCONEX AG May 2015 12 COMPARISON: Standard PCB vs. Noble Metal PCB Standard PCB subtractive copper etching Noble metal PCB additive technology • • • • • • Thick metal Line / Space: > 25 µm Reliable z-axes connection (via) Standard PCB Thin metal Line / Space: < 25 µm Challenging z-axes connection Noble Metal PCB Thick Cu Thin Metal high resolution Reliable vias Biocompatible Electrodes Multilayer Flexible thin PCB Typical build up of a sensor New England 42nd Symposium & Expo © DYCONEX AG May 2015 13 ISO 10993-1:2009 + Cor 1:2010 Regulation Definition of Biocompatibility: “The quality of not having toxic or injurious effects on biological systems.“ * The ISO 10993-1:2009 + Cor 1: 2010 set a series of standards for evaluating the biocompatibility of a medical device prior to a clinical study. ** – 18 different specification points • ISO 10993-1:2009 Biological evaluation of medical devices Part 1: Evaluation and testing in the risk management process • ISO 10993-18:2009 Biological evaluation of medical devices Part 18: Chemical characterization of materials Project Risk Wrong constraint "There is no bio-incompatible material…. …. the dose makes the poison" Patient Risk too carefully too careless Bio PCB Project New England 42nd Symposium & Expo © DYCONEX AG * Dorland's Medical Dictionary ; ** Wikipedia 01.04.2015 14 ISO 10993-1:2009 + Cor 1:2010 Biological Evaluation Tests Blood Path Direct External Tissue bones Device dentin Circulating blood Tissues bones Blood New England 42nd Symposium & Expo © DYCONEX AG o x o o Chronic toxiticity Carcinogenicity x Hemocompabtibility Subacute and subchronic toxiticity x x x x x x x x x x o o x x o x x x o x x o o x x o x x x x x x x o x o x x x x o x x x x x x x x x x o x x x x x x x x x x o x x x x x x x x x x x x x x x x x x x x x - Test according ISO 10993-1 o - Additional Tests (USA) Implantation Mucosal menbrane Breached surface Implant Device x x x x x x x x x x x x x x x x x x x x x x x x Genotoxiticity Skin Surface Device A B C A B C A B C A B C A B C A B C A B C A B C Contact Systematic Toxiticity Category A- limited (< 24 h) B- short term (24h - 30 d) C - permanent (> 30 d) Sensitization Contact Time Nature of Body Contact Cytoxiticity • Not all tests are essential but a base knowledge of ISO 10993 is mandatory • Substrates processed by DYCONEX have been successfully tested for ISO 10993-5 Test for in vitro cytoxicity Biological Effect Irritation or intra cutaneous reaction Medical Device Category o o x x x x o x x x x o x x x x o x x x x x x x x x May 2015 o o x x x o 15 BIOCOMPATIBLE MATERIAL – AVAILABLE OPTIONS • For flexible applications: – Polyimide – LCP • For rigid applications: – Glass – PEEK – Flexible material with a rigid stiffener • Cover materials: – For flexible applications: • Solder mask (can be used for short term implants) • LCP – Parylene coatings New England 42nd Symposium & Expo © DYCONEX AG May 2015 16 APPLICATION: SHORT TERM BLOOD GLUCOSE SENSORS • Compact, handheld, portable device which measures blood glucose levels as part of a diabetes management regimen for the chronic diabetic • Direct implantable bio sensor with clinical approved studies – flexible PCB substrate – flexible cover mask • 30 days in human body • Measures capacitive electric charge current • Typical 3-electrode system Counter Electrode C Reference Electrode Work Electrode Ag/AgCl Au New England 42nd Symposium & Expo Source: http://diabeteshealth.com/media/images/article _images/5060.jpg Source: www.medtronicdiabetes.com © DYCONEX AG May 2015 17 APPLICATION: PERMANENT IMPLANT COCHLEAR ELECTRODES • Need of pure biocompatible materials without copper for long term implant – LCP for excellent biocompatible properties – Au for good adhesion and flexible properties cover mask Pt Au LCP – Pt for selective electrodes robustness • Test design with 125 µm traces on 250 µm pads • Test structures with 15 µm Line / Space N =5.62 % C =2.84 % Au = 91.54 % pure gold electrodes gold + platinum electrodes New England 42nd Symposium & Expo © DYCONEX AG May 2015 18 APPLICATION: THERMISTORS FOR HEAT MEASUREMENTS • Balloon catheters with electrodes for neurostimulation or ablation • • • Invasive surgical procedure Extremely flexible ultra thin 2-layer LCP build up with 50 µm final thickness One thermistor per electrode couple with thin film layer • 25 µm Line / Space • One sided copper plating with 100% via-fill Source: http://de.wikipedia.org/wiki/Angioplastie • Surface finish: electroplated gold on copper for short term implant Source: http://www.p-wholesale.com/ New England 42nd Symposium & Expo © DYCONEX AG May 2015 19 SUMMARY • Advanced LCP processing has been developed to establish fabrication capabilities of complex substrates for RF microwave applications as well as structures for directly implantable medical technologies. • Examples of RF substrate designs are complex multilayer stackups that include cavity structures for bonding of high power die directly to heat sink materials. • Multilayer structures of LCP with noble metal conductors for biocompatible medical implants are also discussed. New England 42nd Symposium & Expo © DYCONEX AG May 2015 20 THANK YOU FOR YOUR ATTENTION! DYCONEX AG Grindelstrasse 40 CH-8303 Bassersdorf Switzerland www.mst.com/dyconex [email protected] Phone +41 (43) 266 11 00 Fax +41 (43) 266 11 01 New England 42nd Symposium & Expo © DYCONEX AG May 2015 21
© Copyright 2024