Maharashtra State Horticulture and Medicinal Plants Board SakharSankul, Shivajinagar, Pune 411 005 Ph: (020)-25534860 Fax : 020-25511302 Email : [email protected] Enlistment of “Manufacturers/Suppliers for Poly House and Net House”for the Year 2015-16 Terms and Conditions 1. “Manufacturers/Suppliers for Poly House and Net House” means the providers of all the specified components/materials along with installation of polyhouse and net house to the cultivators. 2. The Enlistment of manufacturers/suppliers of polyhouses and net houses is compulsory for obtaining subsidy under this scheme. 3. The Enlistment is for the supply of complete polyhouse and net house to the cultivators and not for the supply of individual components/materials of the polyhouse and net house 4. The Enlistment shall be for the State of Maharashtra. 5. The design of polyhouses and net houses must confirm to the models approved by Department of Agriculture/ Maharashtra State Horticulture and Medicinal Plant Board (MSHMPB)/State NHM, Maharashtra State (Annex-1). 6. The poly house and net house manufacturers/suppliers must use all the components required for the installation of polyhouses and net houses confirming to the relevant BIS standards and/or as per specifications provided by the Department of Agriculture/ Maharashtra State Horticulture and Medicinal Plant Board (MSHMPB)/State NHM, Maharashtra State(Annex-2). 7. The manufacturers/suppliers must have at least one service center in Maharashtra. 8. The invoices in respect of supply of polyhouses and net houses shall be raised by the registered manufacturers/suppliers. However the local sub contractor/supplier if any for civil material,installation and transportation work for the polyhouses and net houses installation will be permitted provided that the manufacturers/suppliers undertake the responsibility/guarantee of these works. In such cases invoices/bills given by the subcontractor & authenticated by the manufacturers/suppliers are valid for civil material, installation and transport work only. 9. The manufacturers/suppliers shall under take the responsibility/guaranteeof different components of polyhouses and net houses supplied to the cultivators (Annex-2). 10. The manufacturer /supplier shall undertake to provide guaranty/ warranty as below. (a) Cladding material (polyfilm, all types of net and fabric): One year guarantee (i.e. replacement) against natural wear and tear (excluding the natural calamities, vandalism and any other forced action). Two years warranty (i.e. repairs) against natural wear and tear (excluding the natural calamities, vandalism and any other forced action). (b) Structure: Five years warranty (i.e. repairs) against natural wear and tear (excluding the natural calamities, vandalism and any other forced action)The decision of Managing Director, Maharashtra State Horticulture and Medicinal Plant Board, Pune shall be final in this regard. 11. The manufacturers/suppliers must undertake to supply the components at the rates equal to or less than the rates given as per the Annex-3 and/or the rates per unit area of polyhouse/net house in any case should not be higher than those prescribed in the Annex-4. 12. If Manufacturers/suppliers not follow the rules and regulations mentioned in the Para No. 9,10,11then above the entire Bank Guarantee amount will be deposited in government account and such manufacturers/supplierswill be black listed. Page | 1 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 13. Following documents are required for Enlistment of manufacturers/suppliers(a) Completely filled in application cum company profile in the prescribed Pro-forma (Annex-5). (b) Enlistment feeRs. 10,000.00 (Rupees Ten Thousand only). ThisEnlistment fee is nonrefundable. The Enlistment fee shall be paid in the form of demand draft only, issued in favour of “Managing Director, Maharashtra State Horticulture and Medicinal Plant Board, Pune” payable at Pune along with application for Enlistment. (c) Copy of VAT Enlistment certificate/s. (d) Copy of SSI Enlistment certificate/Enlistment issued by the Director of Industries. (e) Latest Sales Tax clearance certificate (Maharashtra State)/VAT return. (f) The make/brand name/s of different components as per the format given in Annex-6. (g) List of service centers in Maharashtra. Service centre must be as per description given in the item No. 15. (h) Price list of additional components (other than listed in Annex-2 if any) for poly house and net house system as per the format provided in Annex-7. (i) Latest “Certificate of Performance status from the concerned State authority” (Agriculture/Horticulture Department / State Horticulture and Medicinal Plant Board) for the manufacturers/suppliers from outside Maharashtra. They must have regional office in Maharashtra State for better co-ordination and efficient implementation of the scheme. (j) Copy of valid BIS certificates/undertaking by manufacturers/suppliers to supply the different components of polyhouses/net houses according to the specifications provided by the Department of Agriculture/ Maharashtra State Horticulture and Medicinal PlantBoard (MSHMPB)/State NHM, Maharashtra Statefor all components of poly house/shade net house system. (k) Turnover of minimum Rs. 50.00 lakh per year for previous two years which will be counted based on copies of balance sheet. (l) Experience of more than two years for installation and supply of polyhouse/nethousewhich will be counted based on the copies of firm orders/bills amounting to minimum Rs. 25.00 lakh per year. 14. The performance guarantee of Rs. One Lakh in the form of bankguarantee(only of Nationalized bank)in favor of“Managing Director, Maharashtra State Horticulture and Medicinal Plant Board, Pune”according to the format provided in Annex-8 will be required at the time of signing the agreement for Enlistment. The performance guarantee should be renewed after every year. However for the manufacturers/suppliers registered in Maharashtra State as small scale unit, the performance guarantee of Rs. 50,000/- (Rupees Fifty Thousand only) is required. 15. Service Centre: The service center must be of following description(a) The service center should be manned with at least two technical persons; one of them must be an Agricultural Engineer with minimum qualification of B. Tech (Agricultural Engineering). (b) The technical person other than Agricultural Engineer should have completed the training on Polyhouses/Nethouses from one of the State Agricultural Universities (SAUs) or Horticultural Training Center (HTC), TalegaonDabhade. In process of time and as per additional requirements, no. of trained technical persons (either agricultural engineer or trained from SAUs/HTC) should be increased. (c) At least one “service center” shall be located in the State of Maharashtra. (d) The service center must provide free after sales service to the farmers for at least five years. This may exclude the material cost, transportation of material and installation cost. Page | 2 E:\2014-15\guideline\GUIDELINE 2014-15 PC. (e) The service center shall also provide the service as per clause (10) above of these terms and conditions. (f) Service center shall have the information board as per the format provided in Annex-9 or as prescribed by Department of Agriculture/ Maharashtra State Horticulture and Medicinal Plant Board (MSHMPB)/State NHM, Maharashtra State from time to time. (g) Service center shall maintain the list of farmers covered under the scheme. (h) Service center shall maintain the registers as per the format provided in Annex-10 or as prescribed by Department of Agriculture/ Maharashtra State Horticulture and Medicinal Plant Board (MSHMPB)/State NHM, Maharashtra State from time to time. (i) It will be the responsibility of the manufacturer/supplier to see that the service center is kept functional all the year and grievances/complaints of cultivators/farmers are attended to within a week after receiving written complaints. (j) The service center must be equipped with the communication facilities such as phone, internet/email etc. 16. The information furnished for Enlistment should be signed by the competent authority of the manufacturer/supplier. The true copies should be attested by a Gazzetted officer. The competent authority means. (a) For the private and public ltd company: Chairman/CEO/MD or the authorized Person/Director from the Board of Directors. (Copy of resolution passed by the board for this purpose shall be submitted) (b) For Partnership firm/company: One partner duly authorized.(Copy of Authorization signed by all the partners shall be submitted) The above mentioned authorities (as stated in (a) and (b)) will have to submit MOU/Partnership deed in prescribed form. (c) Proprietorship firm/company: Proprietor. 17. The manufacturer must submit the application in prescribed format with all details to the office of the “Managing Director, Maharashtra State Horticulture and Medicinal Plant Board, Pune”. 18. Maharashtra State Horticulture and Medicinal Plant Board (MSHMPB)/State NHM, Maharashtra State reserve the right to reject the Enlistment and the decision of Managing Director, Maharashtra State Horticulture and Medicinal Plant Board, M. S, Pune shall be final in this regard. 19. The Enlistment will be subjected to conditions of guidelines issued by Government of India/Government of Maharashtra/ State Horticulture Mission/ MSHMPB from time to time. 20. These guidelines are available at www.mahanhm.gov.in Managing Director Maharashtra State Horticulture and Medicinal Plants Board, Pune-5 Page | 3 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Annex-1 +) ½þÊ®úiÉMÉÞ½þ =¦ÉÉ®úhÉÒºÉÉ`öÒ ÊxÉζSÉiÉ Eäò±Éä±Éä Ê´ÉÊ´ÉvÉ +É®úÉJÉbä÷ (Designs). ½þÊ®úiÉMÉÞ½þÉSªÉÉ xÉèºÉÌMÉEò ´ÉɪÉÖÊ´ÉVÉxÉ (Open Vent Poly house) ´É ´ÉÉiÉÉ´É®úhÉ ÊxɪÉÆÊjÉiÉ (Climate Control Poly house) |ÉEòÉ®úÉSªÉÉ ½þÊ®úiÉMÉÞ½þɺÉÉ`öÒ +ÉEòÉ®ú¨ÉÉxÉÉxÉÖºÉÉ®ú Ê´ÉÊ´ÉvÉ ¨ÉÉìb÷ä±ºÉ ÊxÉζSÉiÉ Eäò±Éä +ºÉÚxÉ iªÉÉSÉä +É®úÉJÉbä÷ (Designs) {ÉÖføÒ±É|ɨÉÉhÉä +ɽäþiÉ. ±ÉɦÉÉlÉÔxÉÒ ªÉÉ `ö®úÊ´ÉhªÉÉiÉ +ɱÉ䱪ÉÉ +É®úÉJÉb÷¬ÉxÉÖºÉÉ®úSÉ ½þÊ®úiÉMÉÞ½þÉSÉÒ =¦ÉÉ®úhÉÒ Eò®úÉ´ÉÒ. (Êb÷ZÉÉ<ÇxÉ Gò. 1.1 iÉä 2.8) Design No. 1.1 Open Ventilated Polyhouse.(560 Sq.mtrs) OVPH 20 m X 28 m Page | 4 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1.2 Open Ventilated Polyhouse.(1008 Sq.mtrs) OVPH 28m X 36 m Page | 5 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1. 3 Open Ventilated Polyhouse.(1008 Sq.mtrs) OVPH 36 m X 28 m =1008 Page | 6 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1.4 Open Ventilated Polyhouse.(2016 Sq.mtrs) OVPH 36 m X 56 m = 2016 Page | 7 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.5 Open Ventilated Polyhouse.(2080 Sq.mtrs) OVPH 52 m X 40 m =2080 Page | 8 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.6 Open Ventilated Polyhouse.(3120 Sq.mtrs) OVPH 52 m X 60 m =3120 Page | 9 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.7 Open Ventilated Polyhouse.(3120 Sq.mtrs) OVPH 60 m X 52 m =3120 Page | 10 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.8 Open Ventilated Polyhouse.(4080 Sq.mtrs) OVPH 60 m X 68 m =4080 Page | 11 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.9 Open Ventilated Polyhouse.(4000 Sq.mtrs) OVPH 100 m X 40 m =4000 Page | 12 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.1 Climate Controlled Polyhouse.(1008 Sq.mtrs) CCPH 28 m X 36 m = 1008 Page | 13 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.2 Climate Controlled Polyhouse.(1008 Sq.mtrs) CCPH 36 m X 28 m = 1008 Page | 14 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.3 Climate Controlled Polyhouse.(2016 Sq.mtrs) CCPH 36 m X 56 m = 2016 36 Page | 15 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.4 Climate Controlled Polyhouse.(2016 Sq.mtrs) CCPH 52m X 40 m = 2080 Page | 16 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 2.5Climate Controlled Polyhouse.(3120 Sq.mtrs) CCPH 52m X 60 m = 3120 Page | 17 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.6 Climate Controlled Polyhouse.(3120 Sq.mtrs) CCPH 60 m X 52 m = 3120 Page | 18 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.7 Climate Controlled Polyhouse.(4080 Sq.mtrs) CCPH 68 m X 60 m = 4080 Page | 19 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.8 Climate Controlled Polyhouse.(4000 Sq.mtrs) CCPH 100 m X 40 m = 4000 100 40 Page | 20 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ¤É) ¶Éäb÷xÉä]õ½þÉ>ðºÉþ =¦ÉÉ®úhÉÒºÉÉ`öÒ ÊxÉζSÉiÉ Eäò±Éä±Éä Ê´ÉÊ´ÉvÉ +É®úÉJÉbä÷ (Designs). ¶Éäb÷xÉä]õ½þÉ>ðºÉSªÉÉ ®úÉ=Æb÷ ]õÉ<Ç{É (Round Type) ´É }±Éì]õ ]õÉ<Ç{É (Flat Type) ªÉÉ |ÉEòÉ®úÉSªÉÉ ¶Éäb÷xÉä]õ½þÉ>ðºÉºÉÉ`öÒ +ÉEòÉ®ú¨ÉÉxÉÉxÉÖºÉÉ®ú Ê´ÉÊ´ÉvÉ ¨ÉÉìbä÷±ºÉ ÊxÉζSÉiÉ Eäò±Éä +ºÉÚxÉ iªÉÉSÉä +É®úÉJÉbä÷ (Designs) {ÉÖføÒ±É|ɨÉÉhÉä +ɽäþiÉ. ±ÉɦÉÉlÉÔxÉÒ ªÉÉ `ö®úÊ´ÉhªÉÉiÉ +ɱÉ䱪ÉÉ +É®úÉJÉb÷¬ÉxÉÖºÉÉ®úSÉ ¶Éäb÷xÉä]õ½þÉ>ðºÉSÉÒ =¦ÉÉ®úhÉÒ Eò®úÉ´ÉÒ. (Êb÷ZÉÉ<ÇxÉ Gò. 1.1 iÉä 4.8) Design No.1.1 Shadenet house (NHM SNH RT 5 M) 18 m X 28 m = 504 Sq.mtrs. Page | 21 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.2 Shadenet house (NHM SNH RT 5 M) 36 m X 28 m = 1008 Sq.mtrs. Page | 22 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1.3 Shadenet house (NHM SNH RT 5 M) 36 m X 56 m = 2016 Sq.mtrs. Page | 23 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1.4 Shadenet house (NHM SNH RT 5 M) 42 m X 48 m = 2016 Sq.mtrs. Page | 24 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1.5 Shadenet house (NHM SNH RT 5 M) 42 m X 72 m = 3024 Sq.mtrs. 2 Page | 25 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 1.6 Shadenet house (NHM SNH RT 5 M) 48 m X 64 m = 3072 Sq.mtrs. 2 Page | 26 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.7 Shadenet house (NHM SNH RT 5 M) 54m X 56 m = 3024 Sq.mtrs. Page | 27 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1.8 Shadenet house (NHM SNH RT 5 M) 48 m X 84 m = 4032 Sq.mtrs. Page | 28 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1. 9 Shadenet house (NHM SNH RT 5 M) 60 m X 68 m = 4080 Sq.mtrs. Page | 29 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1. 10 Shadenet house (NHM SNH RT 5 M) 72 m X 56 m = 4032 Sq.mtrs. Page | 30 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.1. 11 Shadenet house (NHM SNH RT 5 M) 78 m X 52 m = 4056 Sq.mtrs. Page | 31 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2. 1 Shadenet house (NHM RT 4 M) 18 m X 28 m = 504 Sq.mtrs. 2 Page | 32 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2. 2 Shadenet house (NHM SNH RT 4 M) 36m X 28 m = 1008 Sq.mtrs. 2 Page | 33 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2. 3 Shadenet house (NHM SNH RT 4 M) 36m X 56 m = 2016 Sq.mtrs. 2 Page | 34 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2. 4 Shadenet house (NHM SNH RT 4 M) 42m X 48 m = 2016 Sq.mtrs. 2 Page | 35 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 2.5 Shadenet house (NHM SNH RT 4 M) 42m X 72 m = 3024 Sq.mtrs. 2 Page | 36 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.6 Shadenet house (NHM SNH RT 4 M) 48m X 64 m = 3072 Sq.mtrs. 2 2 Page | 37 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.7 Shadenet house (NHM SNH RT 4 M) 54m X 56 m = 3024 Sq.mtrs. Page | 38 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.8 Shadenet house (NHM SNH RT 4 M) 48 m X 84 m = 4032 Sq.mtrs. 2 Page | 39 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.9 Shadenet house (NHM SNH RT 4 M) 60 m X 68 m = 4080 Sq.mtrs. 2 Page | 40 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No.2.10 Shadenet house (NHM SNH RT 4 M) 72 m X 56 m = 4032 Sq.mtrs. Page | 41 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 2.11 Shadenet house (NHM SNH RT 4 M) 78 m X 52 m = 4056 Sq.mtrs. 2 Page | 42 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.1 Shadenet house (NHMSNH FT 4 M) 20 m X 52 m =1040 Sq.mtrs. Page | 43 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.2 Shadenet house (NHMSNH FT 4 M) 32 m X 34 m =1088 Sq.mtrs. Page | 44 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.3 Shadenet house (NHMSNH FT 4 M) 32 m X 64 m =2048 Sq.mtrs. Page | 45 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.4 Shadenet house (NHMSNH FT 4 M) 44 m X 46 m =2024 Sq.mtrs. Page | 46 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.5 Shadenet house (NHMSNH FT 4 M) 52 m X 58 m =3016 Sq.mtrs. Page | 47 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.6 Shadenet house (NHMSNH FT 4 M) 40 m X 76 m =3040 Sq.mtrs. Page | 48 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.7 Shadenet house (NHMSNH FT 4 M) 40 m X 100 m =4000 Sq.mtrs. Page | 49 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 3.8 Shadenet house (NHMSNH FT 4 M) 64 m X 64 m =4096 Sq.mtrs. Page | 50 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.1 Shadenet house (NHMSNH FT 3.25 M) 22m X 46 m = 1012 Sq.mtrs. Page | 51 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.2 Shadenet house (NHMSNH FT 3.25 M) 40m X 52 m = 2080 Sq.mtrs. Page | 52 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.3 Shadenet house (NHMSNH FT 3.25 M) 52m X 58 m = 3016 Sq.mtrs. Page | 53 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.4 Shadenet house (NHMSNH FT 3.25 M) 40m X 76 m = 3040 Sq.mtrs. Page | 54 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.5 Shadenet house (NHMSNH FT 3.25 M) 40m X 100 m = 4000 Sq.mtrs Page | 55 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.6 Shadenet house (NHMSNH FT 3.25 M) 64m X 64 m = 4096 Sq.mtrs. Page | 56 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.7 Shadenet house (NHMSNH FT 3.25 M) 46 m X 88 m = 4048 Sq.mtrs. Page | 57 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Design No. 4.8 Shadenet house (NHMSNH FT 3.25 M) 58 m X 70 m = 4060 Sq.mtrs. Page | 58 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ANNEX-2 +) ½þÊ®úiÉMÉÞ½þ =¦ÉÉ®úhÉÒºÉÉ`öÒ ±ÉÉMÉhÉÉ-ªÉÉ ºÉÉʽþiªÉÉÆSÉä iÉÉÆÊjÉEò ÊxÉEò¹É ½þÊ®úiÉMÉÞ½þÉSªÉÉ Ê´ÉÊ´ÉvÉ ¨ÉÉìbä÷±ÉxÉÖºÉÉ®ú ´É |ÉEòÉ®úÉxÉÖºÉÉ®ú +ɴɶªÉEò +ºÉhÉÉ-ªÉÉ ºÉÉʽþiªÉÉÆSÉä iÉÉÆÊjÉEò ÊxÉEò¹É {ÉÖÊfø ±É|ɨÉÉhÉä +ɽäþiÉ. iªÉÉxÉÖºÉÉ®ú ±ÉɦÉÉlÉÔxÉÒ ºÉÉʽþiªÉÉÆSÉÉ ´ÉÉ{É®ú ½þÊ®úiÉMÉÞ½þÉSªÉÉ =¦ÉÉ®úhÉÒºÉÉ`öÒ Eò®úÉ´ÉÉ. १) ºÉ´ÉǺÉÉvÉÉ®úhÉ |ÉEòÉ®úSÉä ½þÊ®úiÉMÉÞ½ (NHM-OVPH) =¦ÉÉ®úhÉÒºÉÉ`öÒ Ê´ÉÊ´ÉvÉ ¦ÉÉMÉ/¤ÉɤÉÓºÉÉ`öÒSÉä iÉÉÆÊjÉEò ÊxÉEò¹É. Table No. 1 : General Specifications for OVPH models 1. 2. All members of the structure should be made of Galvanized Iron (GI) with minimum 50 microns thick galvanizing All members should be of minimum 2 mm thickness which shall be verified by equivalent minimum weight as follows- 2 ½"-3.75Kgs/mtr.; 2"-2.9Kgs/mtr.; 1 ½”"-2.3Kgs/mtr.;-1 ¼"2.1Kgs/mtr.; 1"-1.6Kgs/mtr.; ¾"-1.25Kgs/mtr.; ½"-1Kgs/mtr. 3. 4. 5. Members should not be wielded to one another, but fixed with the nut bolts Members should not have any weilded joints upto 6.5 mtrs. length 6. The shape of the Polyhouse should be according to aerodynamic so as to reduce the impact of wind & consequent damage of Polyhouse. The structure should also follow aerodynamics along all four sides with corridors. Grid should be of 4m X 8m 7. 8. 9. 10. 11. 12. The overall slope of the foundation should be between 1.25 % and 2 % so as to keep the Gutter slope accordingly Top height should be minimum 6 mts for Konkan, Marathawada & W. maharashtra and 6.5 mtrs for Khandesh and Vidarbh. Gutter height should be minimum 4 mtrs. Side curtains should be of minimum 2m height for OVPH of area below 1008 Sq.mtrs. and 3m for area above 1009 Sq.mtrs. Top Vent should be of minimum 0.8m height Cross bracing should be provided as follows- Horizontal cross bracing on 4 corners of Polyhouse (For all models)Vertical Cross bracings on 4 corners of Polyhouse (For all models above 1009 Sq.mtrs.) Page | 59 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 2) ºÉ´ÉǺÉÉvÉÉ®úhÉ |ÉEòÉ®úSªÉÉ ÊxÉEò¹É (NHM-OVPH) ½þÊ®úiÉMÉÞ½þɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ VÉÒ. +ɪÉ. {ÉÉ<Ç{ÉSÉä iÉÉÆÊjÉEò Table No. 2 Specification of GI pipe for OVPH Models Sr. No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Particulars Tor bar for hold-fast in foundation Columns Foundations for all columns Truss bottom-Big Truss bottom-Small Sides & Front/Back(F/B) All Corridors Top cross Corridor support members(sides & F/B) Trusses-Top curved members Purlins-(All except curtain) Door column Door Purlins-Curtain Truss members (minimum 5 nos per Bay) Cross bracing Door top Curtain-Universal Runners (for top UV Film) Curtain pipe Curtain handle Curtain guide Size (Outside Diameter) 8mm 76 mm 60 mm 60 mm 48 mm 48 mm 43 mm 43 mm 43 mm 43 mm 43 mm 33 mm 33 mm 33 mm 33 mm 33 mm 33 mm 27 mm 27 mm 27 mm 21 mm Size (Nominal Diameter) n.a. 2 ½” 2” 2” 1 ½” 1 ½” 1 ¼” 1 ¼” 1 ¼” 1 ¼” 1 ¼” 1” 1” 1” 1” 1” 1” ¾” ¾” ¾” ½” Page | 60 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 3) =SSÉ iÉÆjÉYÉÉxÉÉ´É®ú +ÉvÉÉÊ®úiÉ ½þÊ®úiÉMÉÞ½þÉSªÉÉ (NHM-CCPH) =¦ÉÉ®úhÉÒºÉÉ`öÒ ºÉ´ÉǺÉÉvÉÉ®úhÉ iÉÉÆÊjÉEò ÊxÉEò¹É- Table No. 3 General Specification for CCPH Models 1 2 All members of the structure should be made of Galvanized Iron (GI) with minimum 50 microns thick galvanizing All members should be of minimum 2 mm thickness which shall be verified by equivalent 3 4 5 Members should not be wielded to one another, but fixed with the nut bolts Members should not have any weilded joints upto 6.5 mtrs. Length 6 The shape of the Polyhouse should be according to aerodynamic so as to reduce the impact of wind & consequent damage of Polyhouse. The structure should also follow aerodynamics along two sides with corridors. Grid should be of 4m X 8m Top height should be minimum 4.5 mtrs. Gutter height should be minimum 3 mtrs. Excavation of top loose soil upto 0.45 m deep & 0.3m wide, Brick/UCR solling below soil surface of 0.2m depth, 0.1m PCC of 1:4:8, 0.23m Brick wall of 0.15m height below soil surface & 0.6m height above ground surface below the pads & below the fans. Brick wall above ground surface shall be duly plastered with two coats of exterior cement paint. OR A rigid independent strcuture should be provided for installation of Fans, which shall be strong enough so as to give proper suppport to the Fans & prevent the vibrations from being transferred to the polyhouse structure. Enterance Room should be provided which shall be of minimum 2mtrs Wide X 2mtrs.Length X 2.4mtrs. Height, with double door entry system. 7 8 9 10 11 12 13 The overall slope of the foundation should be between 1.25 up to % and 2 % so as to keep the Gutter slope accordingly Distance between the Fans & Pads should not exceed 32mtrs Pads should be necessarily be of Cellulose & no other material shall be allowed Page | 61 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ४÷) =SSÉ iÉÆjÉYÉÉxÉÉ´É®ú +ÉvÉÉÊ®úiÉ (NHM-CCPH) ªÉÉ |ÉEòÉ®úÉSªÉÉ ½þÊ®úiÉMÉÞ½þÉSªÉÉ =¦ÉÉ®úhÉÒºÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ VÉÒ.+ɪÉ.{ÉÉ<Ç{ÉSÉä iÉÉÆÊjÉEò ÊxÉEò¹É. Table No. 4 : Specifications of GI pipe for CCPH models (1) All members shall be of minimum 2 mm thickness. (2) All members should be made of Galvanized Iron (GI). (3) Members should not be welded but fixed with the nut bolts. (4) Members should not have any welded joints, Sr.No. Particulars Size (Outside Diameter) Size (Nominal Diameter) 8mm n.a. 1 Tor bar for hold-fast in foundation 2 All Columns 76 mm 2 ½” 3 Foundations for all Columns 60 mm 2” 4 Truss Bottom-Big 60 mm 2” 5 Truss Bottom-Small F/B 48 mm 1 ½” 6 Truss Bottom-Small Sides 48 mm 1 ½” 7 All Corridors 48 mm 1 ½” 8 Corridor support members 43 mm 1 ¼” 9 Trusses-Top curved members 43 mm 1 ¼” 10 Purlins 43 mm 1 ¼” 11 Door Column 43 mm 1 ¼” 12 Door 33 mm 1” 13 Truss members (minimum 5 nos per Bay) 33 mm 1” 14 Cross bracing 33 mm 1” 15 Door Top 33 mm 1” Page | 62 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 5) ½þÊ®úiÉMÉÞ½þÉSªÉÉ ºÉ´ÉǺÉÉvÉÉ®úhÉ (NHM-OVPH) ´É ´ÉÉiÉÉ´É®úhÉ ÊxɪÉÆÊjÉiÉ |ÉEòÉ®úɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ <iÉ®ú ºÉÉʽþiªÉÉÆSÉä iÉÉÆÊjÉEò ÊxÉEò¹É. (NHM-CCPH) ªÉÉ Table No. 5: Specifications of other items for OVPH and CCPH models Sr.No. Particulars 1 Clamps 2 Nuts & bolts 3 Insect net Laminated wovenPE film for apron Aluminium profiles 4 5 6 Springs 7 Screws 8 Shade net 9 UV film Specification Minimum Pregalvanized G P Sheet 2.0mm thick duly zinc plated.Which resist 400hrs of Salt spray test. Minimum 10mm High tensile duly zinc Plated. Which resist 150hrs of Salt spray test. For structure joint 6-mm8mm shall be allow for pertins titting gutter to perlin 40mesh/50 mesh UV stabilised below curtains. UV stabilized (minimum 140 gsm)and having minimum tearing strenth 140 Kg/m2 should be used for side Apron which shall be of 1m to 1.5m above ground level. Minimum 190grms per mtr. GI Profiles shall not be allowed. Minimum 2.3mm spring steel duly zinc plated& hardened /plastic/powder coated. Minimum 20 mm Self drilling tapping. 35% or 50% UV stabilized shadenet preferably white colour. 95 GSm for 50 % and 75 GSM for 35% Minimum 200 microns thick, UV stabilized diffused Multilayer (Min 3 Layers) Made out of minimum 1mm thick GI or 1.2 mm aluminium HardenedSheet.& minimum 500 mm perimeter trapezoidal section. Door should be made out of UV stabilized FRP with minimum 1mm thickness.& fixed on SS heavy Hinges. 10 Gutter 11 Door 11 GI wire for Shednet Support 12 Pulleys assembly with nuts & bolts 13 Plastic rope 14 Curtain rings UV stablised ropes should be used with minimum 4mm thickness. Visibly strong & effective 15 Curtain clamps Visibly strong & effective. Minimum 12 Gauge G.I wire/PEI min. 2.2 thickess should be used to fix shadenet with sliding arrangement for opening & closing as per requirement. According to standard specification. Page | 63 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 6) =SSÉ iÉÆjÉYÉÉxÉÉ´É®ú +ÉvÉÉÊ®úiÉ (NHM-CCPH) ªÉÉ |ÉEòÉ®úÉSªÉÉ ½þÊ®úiÉMÉÞ½þɨÉvªÉä ´ÉÉiÉÉ´É®úhÉ ÊxɪÉÆjÉhɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ Ê´ÉÊ´ÉvÉ ºÉÉʽþiªÉ ´É ={ÉEò®úhÉÉÆSÉä iÉÉÆÊjÉEò ÊxÉEò¹É. Table No. 6 : Specifications of climate control equipments for CCPH models 1 Exhaust FANS (Minimum 50" size & having about 20000 to 25000 cfm) For effective cooling inside the green house Exhaust Fans having heavy galvanised steel box frame each having capacity of minimum 20000 CFM at 0 static pressure. The number of Fans shall be calculated as per the requirement so as to maintain temperature inside the green house as followsbelow When ambient temperature is 42 C & ambient humidity is 35oC between 3040% BelowWhen ambient temperature is 42 C & ambient humidity is 37oC between 6070% Fans shall have SS blades with aerodynamic design so as to give maximum efficiency with minimum power consumption, and belt driven axcial flow fan, having centrally auto openable louvers & GI sheet & Grills. 2 Cellulose CoolingPADS 4" or 6" thick impregnated cellulose cooling pads of suitable area,calculated so as to maintain the temperature inside the green house as follows below When ambient temperature is 42 C & ambient humidity is 35oC between 3040% BelowWhen ambient temperature is 42 C & ambient humidity is 37oC between 6070% The Pads shall be stifff enough to make it self supporting even at continuous water flow and at the same time is efficiently protected against any decomposition caused by water and air, resulting in minimum working life span of 3 years. 3 4 WATER CIRCULATING SYSTEM FOR PADS FOGGING SYSTEM Water circulating system shall comprise of all Aluminium Frame, Gutter & Cover, PVC Pipe for water distribution on cooling pad so as to wet the pad completely. Fogging system, including 16mm Lateral Pipes at a spacing of 3 mtrs. & make 4 way with antileak distance Foggers at spacing of max. 3 mtrs.PVC submain shall be aloud it buried under ground HDPE Submain, Ball valves, Fittings & accessories, including Disc/Screen Filter & Water storage tank (minimum 1000ltrs.)PVC submain shall be allowed it buried under ground. Brass/SS/PVC Ball Valves, Flush Valves, Disc/Screen Filter, Water storage Tank of min1000 Ltrs. Capacity, Electricity Pump set of ISI mark of sufficient capacity so as to keep the pads always wet. 5 CONTROLL HEAD FOR WATER CIRCULATING SYSTEM 6 Control Head for Fogging system Control head consisting of1) Water storage tank having capacity to hold minimum water requiredfor continuous operation of fogging system for 1 hour, 2) ISI marked Pump having sufficient discharge so as to operate all thefoggers at any given time, at minimum pressure of 35mtrs. at the pointof emitter 3) Sand Filter & Disc Filters having capacity required for above system 4) By-pass assembly, valves, pressure gauge, fitting & accessories 5) Powder coated Panel box including digital timer, MCB, contactors,relays, auto starter, auto manual switch, Voltmeter, wiring, e 7 CONTROLLER 8 CONTROL PANEL BOX For maintaining the proper & adequate temperature & humidity simultaneously inside the Polyhouse a microprocessed based programmable temperaure, Humidity & time based Conroller. User Friendly, with 1 Humidity Probe & 2 temperaure Probes shall be installed. The Controller shall controll Pad Pump, Fogger Pump & Fans individually for controlling climate. The controller shall be provided with suitable constant voltage transformer for the safe working of the controller. All electricals shall be enclosed inside a control panel duly powder coated and consisting of a set of MCB, relays, contactors, manual/Auto Mode including wiring ISI mark copper cable of suitable size & inclosed conduit pipe MCB seperate set for each Fans, Pump of Pad & Pump of Foggers.. 9 Wiring All electricals shall be connected by using ISI marked copper wire cableof required size. These wires shall be enclosed in ISI marked conduit pipe. The entire electrical work shall be certified by licenced electrical engineer. Page | 64 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 7) BäÎSUôEò JÉSÉÇ (Additional Cost forOptional Items) : (½þÊ®úiÉMÉ޽ɺÉÉ`öÒþ) ½þÉ JÉSÉÇ BäÎSUôEò (Optional) +ɽäþ.´É®úÒ±É|ɨÉÉhÉä ½þÊ®úiÉMÉÞ½þÉSªÉÉ |ÉEòÉ®úÉxÉÚºÉÉ®ú ´É +ÉEòÉ®ú¨ÉÉxÉÉxÉÚºÉÉ®ú `ö®úÊ´ÉhªÉÉiÉ +ɱÉ䱪ÉÉ JÉSÉÉÇSªÉÉ +ÆnùÉVÉ{ÉjÉEòÉƨÉvªÉä xɨÉÚnù Eäò±Éä±ÉÉBäÎSUôEòJÉSÉÇ ½þÉ ½þÊ®úiÉMÉÞ½þÉSªÉÉ =¦ÉÉ®úhÉÒºÉÉ`öÒ ±ÉÉMÉhÉÉ-ªÉÉ ºÉÉʽþiªÉÉÆSªÉÉ Bä´ÉVÉÒ {ɪÉÉǪÉÒ Eäò±Éä±ÉÉ +ºÉÉ´ÉÉ. iɺÉäSÉ ªÉÉ BäÎSUôEò º´É°ü{ÉÉSªÉÉ JÉSÉÉǨÉvªÉä JÉɱÉÒ±É|ɨÉÉhÉä ºÉÉʽþiªÉÉSÉÉ {ɪÉÉǪÉÒ ´ÉÉ{É®ú Eäò±ÉÉ MÉ䱪ÉÉºÉ BEÚòhÉ |ÉEò±{É JÉSÉÉÇSªÉÉ VÉɺiÉÒiÉ VÉɺiÉ 5 ]õCEäò ¨ÉªÉÉÇnùäiÉSÉ ºÉnù®úSÉÉ BäÎSUôEò JÉSÉÇ näùªÉ ®úÉʽþ±É. ±ÉɦÉÉlÉÔxÉä ºÉnù®úSÉÉ BäÎSUôEòJÉSÉÇ Eäò±ÉÉ xɺɱªÉÉºÉ ªÉÉ ¤ÉɤÉÒ+ÆiÉMÉÇiÉ +xÉÖnùÉxÉ näùªÉ ½þÉähÉÉ®ú xÉɽþÒ. iɺÉäSÉ ±ÉɦÉÉlÉÔxÉä +¶ÉÉ|ÉEòÉ®úSÉÉ BäÎSUôEò {ɪÉÉǪÉÒ JÉSÉÇ Eäò±ªÉÉSÉÒ JÉÉjÉÒ ºÉƤÉÆÊvÉiÉ +ÊvÉEòÉ-ªÉÉxÉä Eò®úÉ´ÉÒ. xÉèºÉÌMÉEò ´ÉɪÉÖÊ´ÉVÉxÉ ´É =SSÉiÉÆjÉYÉÉxÉÉ´É®ú +ÉvÉÉÊ®úiÉ ½þÊ®úiÉMÉÞ½þɺÉÉ`öÒ BäÎSUôEò JÉSÉÉÇSÉÉ iÉ{ɶÉÒ±É. Tabel No. 7 +.Gò. {ɪÉÉǪÉÒ ºÉÉʽþiªÉ ´ÉÉ{É®úÉSÉÉ iÉ{ɶÉÒ±É 1 ¶Éäb÷xÉä]õSªÉÉ (]äõ{ÉxÉä]õ) Bä´ÉVÉÒ ¶Éäb÷xÉä]õSÉÉ (¨ÉÉäxÉÉäxÉä]) ´ÉÉ{É®ú Eäò±ªÉɺÉ(Use of Mononet instead of Shadenet (Tape net) 2 ¶Éäb÷xÉä]õSªÉÉ (]äõ{ÉxÉä]õ) Bä´ÉVÉÒ GòÉä¨ÉìÊ]õEò xÉä]õSÉÉ ´ÉÉ{É®ú Eäò±ªÉÉºÉ (Use of Chromatic net instead 4 (+) °ü. 10/- |ÉÊiÉ SÉÉè.¨ÉÒ. SÉÉè.¨ÉÒ. (+) °ü. 25/- |ÉÊiÉ SÉÉè.¨ÉÒ. SÉÉè.¨ÉÒ. (+) °ü. 65/- |ÉÊiÉ SÉÉè.¨ÉÒ. SÉÉè.¨ÉÒ. ( ) °ü. 10/- |ÉÊiÉ SÉÉè.¨ÉÒ. ÊEò±ÉÉä. (+) °ü. 65/- |ÉÊiÉ ÊEò±ÉÉä. ) ¡òCiÉ ¤ÉÉVÉÚ±ÉÉ ÊEò]õEò®úÉävÉEò VÉɳýÒ Bä´ÉVÉÒ ¶Éäb÷xÉä]õSÉÉ (]äõ{ÉxÉä]õ)´ÉÉ{É®ú Eäò±ªÉɺÉ(Use of Shadenet (Tape net) instead of Insect netQuantity only on sides 5 SÉÉè.¨ÉÒ. ) ¶Éäb÷xÉä]õSªÉÉ (]äõ{ÉxÉä]õ) Bä´ÉVÉÒ lɨÉDZÉxÉä]õSÉÉ ´ÉÉ{É®ú Eäò±ªÉÉºÉ (Use of Thermal net instead of Shadenet (Tape net) ºÉ´ÉǺÉÉvÉÉ®úhÉ{ÉhÉä nù®úɨÉvÉÒ±É ¡ò®úEò ) of Shadenet (Tape net) 3 {ÉÊ®ú¨ÉÉhÉ (ªÉÚÊxÉ]õ) _ ) ¨ÉÉä`ö¬É +ÉEòÉ®úÉSªÉÉ VÉÒ.+ɪÉ.MÉ]õ®ú¶ÉÒ]õSÉÉ ´ÉÉ{É®ú Eäò±ªÉɺÉ(Use of Higher size of GI gutter sheet) (estimate extra weight) ) Page | 65 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Tabel No 8. List of Optional items that can be considered for subsidy if actually installed on site & invoices provided Subsidy will be 50% of - "Maximum Cost or actual cost as per invoice" whichever is less Maximum Maximum cost to be considered for following Sr. List of Items & their specifications Cost in OVPH/SNH models No. Rupees 1 Lux meter digital 2 Wet bulb Dry bulb thermometer 3 Tensiometers Tensiometer Standard model fitted with suction meter, 0-100 centibar vacuum, with screwable ceramic tip and translucent head assembly with water trap: following sizes 15cm 30cm 45cm 60cm 75cm 90cm AccessoriesTensiometer insertion coring tool Hand suction Tensiometer priming syringe Tensiometer gauge recording chart (monthly) – pack of 12 Air circulating Fans ( to be used only 4 when air circulation is limited due to following reasons-1) big area , 2) Less wind flow, 3) use of insect nets/bionets on sides & subsidy will only be applicable for structures above 2000 Models) 5000 1500 4778 4918 5123 5289 5391 5557 2223 881 256 1000 5000 1500 2000 5000 1500 3000 5000 1500 4000 5000 1500 9836 9836 10246 10246 9836 10246 9836 10246 2223 881 256 2223 881 256 2223 881 256 2223 881 256 0 42000 54000 60000 Each air circulating fans should have minimum 6 nos. of SS blades with following specifications as per the sizes Number of fans to be allowed for subsidy should be limited as follows Model-1000 Notallowed Model-2000 Maximum 7 Nos. Model-3000 Maximum 9 Nos. Model-4000 Size 18" 24" 30" 36" Maximum 10 Nos. 4500 5000 6000 7500 Page | 66 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 5 Fertilizer injecting unitsa Gator pump b Venturi c HTP single piston pump (with electric motor & panel box) d HTP double piston pump (with electric motor & panel box) Self acting diaphragm pump e Self acting piston pump 6 PH measuring devices 7 EC measuring devices 8 Cladding material used The cost will be calculated by multiplying the total area of cladding material used (as given in the detailed estimates) by the following additional cost which is given in Rs. Per Sq.mtrs. i) Cladding material used on Roof a Shadenet (Mononet) instead of Shadenet (Tape net) b Insect net instead of Shadenet (Tape net) Chromatic coloured net (the c supplier should warranty that the colour will not fade for minimum 3 years) instead of Shadenet (Tape net) Thermal net instead of Shadenet (Tape net) to be allowed only for roof ii)Cladding material used on sides Shadenet (Tape net) instead of Insect net Total in Rupees Rate Rs Per Sq.mtrs. d 5000 3500 25000 25000 25000 25000 25000 10000 10000 10000 10000 10000 10000 10000 10000 54000 108000 162000 216000 129942 226942 293942 354942 130 113 98 89 35000 10000 18000 10000 10000 10 15 20 60 -15 Page | 67 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of Control head for Irrigation (Item No F(a) mentioned in detail estimates of all OVPH, SNH-RT, SNHFT models) systems for various models 1 Sr. No. I Table No.9.1: NHM(OVPH/SNH-RT/SNH-FT) - 500 models Submain Discharge Control headModel NHM-OVPH-500 LPH 500 Size (m) 20 28 Drip Foggers Area 560 4978 1742 (Sq.mtrs.) Particulars Rate (Rs) Unit Quantity Estimated Amount Rupees Cost of material 1 Concrete Bed - 6 Sq.mtrs. 6000 Unit 0 0 2 Pump 1.5 HP 9500 Nos. 1 9500 3 Water Storage Tank 5 Ltrs. 1000 5000 4 Pane Box with timer 7000 Nos. 1 7000 5 Sand Filter 10 m3/hr. 11500 Nos. 1 11500 6 Disc Filter 10 m3/hr. 3000 Nos. 1 3000 7 GI fittings & accessories 2000 Nos. 1 2000 8 By pass assembly 1500 Nos. 1 1500 Sub Total VAT (compulsory) 39500 5% Total Material Cost II Installation cost 41475 5% Grand total Unit rate 1975 2074 43549 Rs/Sq.mtrs. 77.77 Page | 68 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.9.2:NHM(OVPH/SNH-RT/SNH-FT) - 1000 models 2 Control head1000 Model Size (m) Area(Sq.mtrs.) Particulars Sr. No. A 28 1008 Rate (Rs) Submain Discharge LPH 36 Drip Foggers 8960 3136 Unit Quantity Amount Estimated Rupees Cost of material 1 2 3 4 5 6 7 8 B NHM-OVPH-500 Concrete Bed - 6 Sq.mtrs. Pump 2.0 HP Water Storage Tank Pane Box with timer Sand Filter 10 m3/hr. Disc Filter 10 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 6000 15500 5 7000 11500 3000 2000 1500 5% 5% Rs/Sq.mtrs. Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Nos. 1 1 3000 1 1 1 1 1 6000 15500 15000 7000 11500 3000 2000 1500 61500 3075 64575 3229 67804 67.27 Page | 69 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.9.3 : NHM(OVPH/SNH-RT/SNH-FT) - 2000 models 3 Control head2000 Sr. No. A NHM-OVPH-500 Size (m) Area(Sq.mtrs.) Particulars 36 2016 Rate (Rs) Submain Discharge LPH 56 Drip 17920 Foggers 6272 Unit Quantity Amount Estimated Rupees Cost of material 1 2 3 4 5 6 7 8 B Model Concrete Bed - 6 Sq.mtrs. Pump 3.0 HP Water Storage Tank Pane Box with timer Sand Filter 25 m3/hr. Disc Filter 25 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 6000 18500 5 7000 20500 6500 4000 1500 5% 5% Rs/Sq.mtrs. Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Nos. 1 1 7000 1 1 1 1 1 6000 18500 35000 7000 20500 6500 4000 1500 99000 4950 103950 5198 109148 54.14 Page | 70 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 4 Table No.9.4 : NHM(OVPH/SNH-RT/SNH-FT) - 3000 models Control headModel NHM-OVPH-500 Total Discharge LPH 3000 Size (m) 52 60 Drip Foggers Area 3120 27733 9707 (Sq.mtrs.) Sr. No. A Particulars Rate (Rs) Unit Quantity Amount Estimated Rupees 1 Concrete Bed - 6 Sq.mtrs. 6000 Unit 2 12000 2 Pump 5.0 HP 22500 Nos. 1 22500 3 Water Storage Tank 5 Ltrs. 10000 50000 4 Pane Box with timer 7000 Nos. 1 7000 5 Sand Filter 25 m3/hr. 20500 Nos. 1 20500 6 Disc Filter 25 m3/hr. 6500 Nos. 1 6500 7 GI fittings & accessories 5000 Nos. 1 5000 8 By pass assembly 1500 Nos. 1 1500 Cost of material Sub Total VAT (compulsory) 125000 5% Total Material Cost B Installation cost 131250 5% Grand total Unit rate 6250 6563 137813 Rs/Sq.mtrs. 44.17 Page | 71 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.9.5 : NHM(OVPH/SNH-RT/SNH-FT) - 4000 models 5 Control head4000 Sr. No. A Particulars NHM-OVPH-500 40 100 4000 Rate (Rs) Unit 6000 22500 5 7000 20500 6500 5000 1500 Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Nos. Total Discharge LPH Drip Foggers 35556 12444 Quantity Estimated Amount Rupees Cost of material 1 2 3 4 5 6 7 8 B Model Size (m) Area (Sq.mtrs.) Concrete Bed - 6 Sq.mtrs. Pump 5.0 HP Water Storage Tank Pane Box with timer Sand Filter 25 m3/hr. Disc Filter 25 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% 5% Rs/Sq.mtrs. 2 1 12500 1 1 1 1 1 12000 22500 62500 7000 20500 6500 5000 1500 137500 6875 144375 7219 151594 37.90 Page | 72 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ¶Éäb÷xÉä]õ ½þÉ>ðºÉSªÉÉ ®úÉ>Æðb÷ ]õÉ<Ç{É (RT) ´É }±Éì]õ ]õÉ<Ç{É (FT) |ÉEòÉ®úɺÉÉ`öÒ ºÉɨÉÉʪÉEòò iÉÉÆÊjÉEò ÊxÉEò¹É {ÉÖføÒ±É|ɨÉÉhÉä +ɽäþiÉ. Common Specifications for FT and RT models Note: 1) All pipes should be made of Galvanized Iron (GI). 2) All pipes shall be of minimum 2 mm thickness. 3) Pipes should not be welded but fixed with the nut bolts. 4) Pipe should not have any wielded joint up to 6 meters 5) Height for FT should be 4.00 meter and LC model should beminimum 3.25 6) Height for RT model should be minimum 5.00 m. at the centre, Height -5 m. & side height -4m and Span 4 X 6 m ¶Éäb÷xÉä]õ ½þÉ>ðºÉSªÉÉ RT |ÉEòÉ®úɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ VÉÒ.+ɪÉ. {ÉÉ<Ç{ÉSÉä iÉÉÆÊjÉEò ÊxÉEò¹É {ÉÖføÒ±É|ɨÉÉhÉä +ɽäþiÉ. Table No. - 1 T RT Models – 6 X 4 m, Center Height -5m and Sideheight-4m More Height model Size Size Sr.No. Particulars (Nominal Diameter) (Outside Diameter) 1 Tor bar for hold-fast in foundation 8mm n.a. 2 Foundation for columns 48mm 1½“ 3 Columns 60mm 2’’ 4 Truss bend 48mm 1½“ 5 Purlins 43mm 1¼“ 6 Truss Bottom 43mm 1¼“ 7 Truss Member 43mm 1 ¼" 8 Door 33mm 1” 9 Door Coloumn 43mm 1 ¼" 10 Door top 33mm 1” Corridor (Hocky) No Corridors Page | 73 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No. -2: RT Models – 6 X 4 m, Center Height -4 m Less Height model Size Size Sr.No. Particulars (Nominal Diameter) (Outside Diameter) 1 Tor bar for hold-fast in foundation 8mm n.a. 2 Foundation for columns 48mm 1½“ 3 all columns 60mm 2“ 4 Truss bend 48mm 1½“ 5 Purlins 43mm 1¼“ 6 Truss Bottom 33mm 1” 7 Truss Member 33mm 1” 8 Door 33mm 1” 9 Door Coloumn 33mm 1” 10 Door top 33mm 1” 11 Corridor (Hocky) No Corridors Page | 74 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ¶Éäb÷xÉä]õ ½þÉ>ðºÉSªÉÉ FT|ÉEòÉ®úɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ VÉÒ.+ɪÉ. {ÉÉ<Ç{ÉSÉä iÉÉÆÊjÉEò ÊxÉEò¹É {ÉÖføÒ±É|ɨÉÉhÉä +ɽäþiÉ. Table No. -3: FT Models - Span - 4X6m,Height -4mMore height Model Sr.No. 1 2 3 Size Size (Outside Diameter) (Nominal Diameter) Particulars Tor bar for hold-fast in foundation Foundation for main Columns n.a. 8mm 1½“ 48mm 1 ¼” Foundation for periphery middle Columns 43mm 4 Main Coloumns 60 mm 5 Periphery Middle Coloumns 48mm 6 Truss 43 mm 1 ¼” 7 Purlin 43 mm 1 ¼” 8 Main Corridor 48 mm 1½“ 9 Middle Corridor 43 mm 1 ¼” 10 Door 33 mm 1” 11 Door coloumn 43 mm 1 ¼” 12 Door corridor 43 mm 1 ¼” 13 Door top 33 mm 1” 14 2m Wide periphery corridors on all 4 sides shall be used 2” 1½“ Page | 75 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Eò¨ÉÒ =ÆSÉÒSÉä ¶Éäb÷xÉä]õ ½þÉ>ðºÉSªÉÉ FT|ÉEòÉ®úɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ VÉÒ.+ɪÉ. {ÉÉ<Ç{ÉSÉä iÉÉÆÊjÉEò ÊxÉEò¹É {ÉÖføÒ±É|ɨÉÉhÉä +ɽäþiÉ. Table No. -4: FT Models - Span –6 X6m, Height -3.25 m Less height Models Sr.No. 1 2 3 Particulars Tor bar for hold-fast in foundation Foundation for main Columns Size Size (Outside (Nominal Diameter) Diameter) n.a. 8mm 1 ¼” 43mm 1” Foundation for periphery middle Columns 33mm 4 Main Coloumns 48mm 5 periphery middle Columns 43 mm 6 Truss 33 mm 1” 7 Purlin 33 mm 1” 8 Main Corridor 43 mm 1 ¼” 9 Middle Corridor 33 mm 1” 10 Door 33 mm 1” 11 Door coloumn 33 mm 1” 12 Door corridor 33 mm 1” 13 Door top 33 mm 1” 14 1 ½” 1 ¼” 2m Wide periphery corridors on all 4 sides shall be used Page | 76 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ¶Éäb÷xÉä]õ ½þÉ>ðºÉSªÉÉ RT ´É FT |ÉEòÉ®úɺÉÉ`öÒ ´ÉÉ{É®úhªÉÉiÉ ªÉɴɪÉÉSªÉÉ <iÉ®ú ºÉÉʽþiªÉÉÆSÉä iÉÉÆÊjÉEò ÊxÉEò¹É {ÉÖføÒ±É|ɨÉÉhÉä+ɽäþiÉ. Table No. -5: Specifications of other items for FT and RT models Sr.No. Particulars Specifications 1 Clamps Made out of pre galvanised sheet having minimum 2.5mm thickness & shall resist 400 hours of salt spray test High tensile nuts & bolts of minimum 8mm thick, duly zinc plated & shall resist 150 hours of salt spray test 40mesh/50 mesh UV stabilised & having minimum weight of 110 gsm UV stabilized, having minimum 100 gsm weight & minimum tear strength of 100 Kg/cm2 should be used for side apron which shall be minimum 1m above ground level 2 Nuts & bolts 3 Insect net 4 Laminated woven film for apron 5 Aluminium profiles Minimum 190 gms per mtr. 6 Springs 7 Screws 8 Shade net Tape net 9 Shade net Mono net 10 Door Minimum 2.3 mm thick spring steel, duly hardened & zinc plated/plastic coated/powder coated Min. 20 mm Self drilling tapping 35% to 50% UV stabilized shadenet, preferably white colour & having minimum 95 gsm for 50 % & 75 gsm for 35 % 35% to 50% UV stabilized shadenet, preferably white colour & having minimum 95 gsm for 50 % & 75 gsm for 35 % Door should be made out of UV stabilized FRP with minimum 1mmthickness.& fixed on SS heavy Hinges. Page | 77 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of Control head for Foggers -Item No A (21) mentioned in detail estimates of all CCPH models Table No.10.1 : NHM CCPH - 500 models 1 Control head500 Sr. No. A NHM-OVPH-500 Size (m) Area (Sq.mtrs.) Particulars 20 28 560 Rate (Rs) Unit 6000 9500 5 11500 3000 2000 1500 Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Submain Discharge LPH Drip Foggers 4978 1742 Quantity Estimated Amount Rupees Cost of material 1 2 3 4 5 6 7 B Model Concrete Bed - 6 Sq.mtrs. Pump 1.0 HP Water Storage Tank Sand Filter 10 m3/hr. Disc Filter 10 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% Rs/Sq.mtrs. 1 1 2000 1 1 1 1 6000 9500 10000 11500 3000 2000 1500 43500 0 43500 2175 45675 81.56 Page | 78 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.10.2 : NHM CCPH - 1000 models 2 Control head1000 Sr. No. NHM-OVPH-500 Size (m) Area (Sq.mtrs.) Particulars A 28 36 1008 Rate (Rs) Unit 6000 15500 5 12500 3500 3000 1500 Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Submain Discharge LPH Drip Foggers 8960 3136 Quantity Amount Estimated Rupees Cost of material 1 2 3 4 5 6 7 B Model Concrete Bed - 6 Sq.mtrs. Pump 2.0 HP Water Storage Tank Sand Filter 10 m3/hr. Disc Filter 10 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% Rs/Sq.mtrs. 1 1 3000 1 1 1 1 6000 15500 15000 12500 3500 3000 1500 57000 0 57000 2850 59850 59.38 Page | 79 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.10.3 : NHM CCPH - 2000 models 3 Control head2000 Sr. No. A NHM-OVPH-500 Size (m) Area (Sq.mtrs.) Particulars 36 56 2016 Rate (Rs) Unit Submain Discharge LPH Drip Foggers 17920 6272 Quantity Estimated Amount Rupees Cost of material 1 2 3 4 5 6 7 B Model Sub Total 6000 18500 35000 20500 6500 4000 1500 92000 VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 0 92000 4600 96600 47.92 Concrete Bed - 6 Sq.mtrs. Pump 3.0 HP Water Storage Tank Sand Filter 25 m3/hr. Disc Filter 25 m3/hr. GI fittings & accessories By pass assembly 6000 18500 5 20500 6500 4000 1500 5% Rs/Sq.mtrs. Unit Nos. Ltrs. Nos. Nos. Nos. Nos. 1 1 7000 1 1 1 1 Page | 80 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.10.4 : NHM CCPH - 3000 models 4 Control head3000 Sr. No. Particulars A NHM-OVPH-500 52 60 3120 Rate (Rs) Unit 6000 22500 5 20500 6500 5000 1500 Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Total Discharge LPH Drip Foggers 27733 9707 Quantity Amount Estimated Rupees Cost of material 1 2 3 4 5 6 7 B Model Size (m) Area (Sq.mtrs.) Concrete Bed - 6 Sq.mtrs. Pump 5.0 HP Water Storage Tank Sand Filter 25 m3/hr. Disc Filter 25 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% Rs/Sq.mtrs. 2 1 10000 1 1 1 1 12000 22500 50000 20500 6500 5000 1500 118000 0 118000 5900 123900 39.71 Page | 81 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No.10.5 :CCPH- 4000 Models 5 Control head4000 Sr. No. A Particulars NHM-OVPH-500 60 68 4080 Rate (Rs) Unit 6000 22500 5 20500 6500 5000 1500 Unit Nos. Ltrs. Nos. Nos. Nos. Nos. Total Discharge LPH Drip Foggers 36267 12693 Quantity Estimated Amount Rupees Cost of material 1 2 3 4 5 6 7 B Model Size (m) Area (Sq.mtrs.) Concrete Bed - 6 Sq.mtrs. Pump 5.0 HP Water Storage Tank Sand Filter 25 m3/hr. Disc Filter 25 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% Rs/Sq.mtrs. 2 1 12500 1 1 1 1 12000 22500 62500 20500 6500 5000 1500 130500 0 130500 6525 137025 33.58 Page | 82 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of Control head for pad circulation -Item No A (20) mentioned in detail estimates of all CCPH models Table No. 11.1 NHM CCPH - 500 models 1 Control head500 Sr. No. A NHM-OVPH-500 Size (m) Area (Sq.mtrs.) Particulars 20 28 560 Rate (Rs) Unit Submain Discharge LPH Drip Foggers 4978 1742 Quantity Estimated Amount Rupees Cost of material 1 2 3 4 5 6 B Model Pump 0.5 HP Water Storage Tank Sand Filter 10 m3/hr. Disc Filter 10 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 7500 5 11500 3000 2000 1500 5% Rs/Sq.mtrs. Nos. Ltrs. Nos. Nos. Nos. Nos. 1 500 1 1 1 1 7500 2500 11500 3000 2000 1500 28000 0 28000 1400 29400 52.50 Page | 83 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No. 11.2 NHM CCPH - 1000 models 2 Control head1000 Sr. No. NHM-OVPH-500 Size (m) Area (Sq.mtrs.) Particulars A 28 36 1008 Rate (Rs) Unit 12500 5 12500 3500 3000 1500 Nos. Ltrs. Nos. Nos. Nos. Nos. Submain Discharge LPH Drip Foggers 8960 3136 Quantity Amount Estimated Rupees Cost of material 1 2 3 4 5 6 B Model Pump 1.5 HP Water Storage Tank Sand Filter 10 m3/hr. Disc Filter 10 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% Rs/Sq.mtrs. 1 3000 1 1 1 1 12500 15000 12500 3500 3000 1500 48000 0 48000 2400 50400 50.00 Page | 84 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No. 11.3 NHM CCPH - 2000 models 3 Control head2000 Sr. No. A NHM-OVPH-500 Size (m) Area (Sq.mtrs.) Particulars 36 56 2016 Rate (Rs) Unit 15500 5 20500 6500 4000 1500 Nos. Ltrs. Nos. Nos. Nos. Nos. Submain Discharge LPH Drip Foggers 17920 6272 Quantity Estimated Amount Rupees Cost of material 1 2 3 4 5 6 B Model Pump 2.0 HP Water Storage Tank Sand Filter 25 m3/hr. Disc Filter 25 m3/hr. GI fittings & accessories By pass assembly Sub Total VAT (compulsory) Total Material Cost Installation cost Grand total Unit rate 5% Rs/Sq.mtrs. 1 7000 1 1 1 1 15500 35000 20500 6500 4000 1500 83000 0 83000 4150 87150 43.23 Page | 85 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No. 12 Specifications for irrigation system -drip / mini sprinkler / overhead irrigation fas per item no F-(b) mentioned in detail estimates of all NHM models 1 Power supply arrangement should be available at site 2 Lateral size should not be less than 16mm OD & minimum Class-II 3 Emitters spacing in drip irrigation should not be more than 0.3m 4 Emitters discharge in drip irrigation should not be more than 2lph 5 Lateral length in drip irrigation should not exceed 40 mtrs. 6 Submain should be necessarily be of HDPE 7 Mini sprinkler & overhead irrigation systems should be designed to achieve minimum Emission Uniformity of 85% 8 If any of the above specifications are not followed then no subsidy will be sanctioned for this item Table No. 13 Specifications for fogging system as per item no F-(c) mentioned in detail estimates of all NHM models 1 Power supply arrangement should be available at site 2 Lateral size should not be less than 16mm OD 3 Emitters spacing should not be less than 3m x 3m grid 4 Emitters discharge should not be more than 7.5 lph per fogger i.e. 7.5x4 =30 lph per 4-way 5 Submain should be necessarily be of HDPE 6 Lateral length should not exceed 40 mtrs. Foggers should be able to creat droplet sizes of less than 90 microns (supported by the 7 literature) 8 Foggers pump should be operated by auto digital timers 9 Foggers should be operated at minimum 3 kg/cm2 10 Foggers should be provided with drainage prevent devices. 11 If any of the above specifications are not followed then no subsidy will be sanctioned for this item Page | 86 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ANNEX-3 ½þÊ®úiÉMÉÞ½þÉSªÉÉ |ÉEòÉ®úÉxÉÖºÉÉ®ú ´É +ÉEòÉ®ú¨ÉÉxÉÉxÉÚºÉÉ®ú iɺÉäSÉ iÉÉÆÊjÉEò {ÉÊ®ú¨ÉÉhÉÉxÉÚºÉÉ®ú ºÉʴɺiÉ®ú JÉSÉÉÇSÉÒ +ÆnùÉVÉ{ÉjÉEä÷ (Estimates)÷ {ÉÖføÒ±É {ÉÉxÉÉ´É®ú Ênù±ÉÒ +ɽäþiÉ. (Table No. 1.1 to 2.4) The detail estimates of NHM-OVPH models Table No.1.1 The detail estimates of NHM-OVPH-500 model Model NHM-OVPH-500 Structural material G.I. Pipes Size 560 sq m Dimensions 20 m x 28 m 28m x 20 m Height Minimum 6.5 m at center 20 m x 28 m Rate Particulars Unit 560 (Rs) Sr. No. Quantity A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 B C 1 2 3 D E F G Cost of Material GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Curtain Clamps Pulley assembly Curtain Rings UV stabilised FRP-Door Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head b) Irrigation System c) Fogging System Irrigation System Total Unit Rate Optional Items as per table no 8 Max limit 65 55 65 45 22 25 40 43 10 8 1.5 60 4 10 30 2 3000 Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Mtrs. Nos. Nos. Nos. Nos. 2791 1101 115 406 560 428 252 126 590 560 775 13 145 67 8 84 1 5% 150 Nos. 70 120 70 Sq.mtrs. Nos. Sq.mtrs. 12.36% 2.00% Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 56 560 56 560 Amount (Rs) 181415 60555 7475 18270 12320 10700 10080 5418 5900 4480 1163 780 580 670 240 168 3000 323214 16161 339374 8400 39200 6720 39200 85120 432894 10521 8658 452073 807 78 25 25 128 935 0 Page | 87 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-OVPH models Table No.1.2 The detail estimates of NHM-OVPH-1008 model Model NHM-OVPH-1008 Structural material G.I. Pipes Size 1008 sq m Dimensions 28 m X 36 m,36 m X 28 m Height Minimum 6.5 m at center 28 m X 36 m 1008 Particulars Rate (Rs) Unit Sr. No. Quantity A Amount (Rs) 36 m X 28 m 1008 Quanti ty Amount (Rs) Cost of Material 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 B C 1 2 3 D E F G GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Curtain Clamps Pulley assembly Curtain Rings UV stabilised FRP-Door Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head b) Irrigation System c) Fogging System Irrigation System 65 55 65 45 22 25 40 43 10 8 1.5 60 4 10 30 2 3000 Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Mtrs. Nos. Nos. Nos. Nos. 4805 1809 287 676 1008 840 353 176 983 1008 1290 24 231 93 16 108 1 5% 150 Nos. 68 120 68 Sq.mtrs. Nos. Sq.mtrs. 12.36% 2.00% Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Total Unit Rate Rs/Sq.mtr Optional Items as per table no 8 Max limit Rs/Sq.mtr 83 1008 83 1008 312325 99495 18655 30420 22176 21000 14120 7568 9830 8064 1935 1440 924 930 480 216 3000 552578 27629 580207 12450 4872 1862 325 699 1008 832 353 176 1017 1008 1335 24 218 93 12 84 1 68544 9960 68544 147048 739705 18175 14794 772674 767 67 25 25 117 1008 82 1008 82 316680 102410 21125 31455 22176 20800 14120 7568 10170 8064 2002.5 1440 872 930 360 168 3000 563341 28167 591508 12300 884 68544 9840 68544 146928 750736 18160 15015 783911 778 67 25 25 117 895 (näùªÉ 890) 51 40 Page | 88 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-OVPH models Table No.1.3 - The detail estimates of NHM-OVPH-2000 model Model Structural material NHM-OVPH-2000 G.I. Pipes Size 2016 sq m & 2080 sqm Dimensions 36 m x56 m 52 m X 40 m Height Sr. No. Minimum 6.5 m at center Particulars A Cost of Material 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Curtain Clamps Pulley assembly Curtain Rings UV stabilised FRP-Door Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head b) Irrigation System c) Fogging System Irrigation System Total Unit Rate 16 17 B C 1 2 3 D E F G Optional Items as per table no 8 Max limit 36 m X 56 m 2016 Rate (Rs) Unit 65 55 65 45 22 25 40 43 10 8 1.5 60 4 10 30 2 3000 Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Mtrs. Nos. Nos. Nos. Nos. 9641 3303 680 1254 2016 1802 530 265 1824 2016 2394 51 428 140 24 336 1 150 Nos. 138 66 120 66 Sq.mtrs. Nos. Sq.mtrs. 2016 138 2016 Quantity 52 m X 40 m 2080 Amount (Rs) Quant ity 626665 181665 44200 56430 44352 45050 21200 11395 18240 16128 3591 3060 1712 1400 720 672 3000 1079480 53974 1133454 20700 9891 3493 795 1336 2080 1852 529 265 1945 2080 2551 52 410 140 26 240 1 2080 138 2080 Rs/Sq.mtr 133056 16560 133056 282672 1436826 34938 28737 1500501 744 54 25 25 104 848 Rs/Sq.mtr 42 5% 12.36% 2.00% Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 138 Amount (Rs) 642915 192115 51675 60120 45760 46300 21160 11395 19450 16640 3826.5 3120 1640 1400 780 480 3000 1121777 56089 1158721 20700 137280 16560 104000 257840 1437261 31869 28745 1497875 720 54 25 25 104 824 66 Page | 89 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-OVPH models Table No.1.4 The detail estimates of NHM-OVPH-3000 model Model NHM-OVPH-3000 Structural material G.I. Pipes Size 3120 sq m Dimensions 52 m X 60 m 60 m X 52 m Height Minimum 6.5 m at center 52 m X 60 m Sr. Rate 3120 Particulars Unit No. (Rs) Amount Quantity A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 B C 1 2 3 D E F G (Rs) 60 m X 52 m 3120 Quantity Amount (Rs) Cost of Material GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Curtain Clamps Pulley assembly Curtain Rings UV stabilised FRP-Door Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head b) Irrigation System c) Fogging System Irrigation System Total Unit Rate Optional Items as per table no 8 Max limit Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Mtrs. Nos. Nos. Nos. Nos. 14530 4942 1216 1908 3120 2881 655 328 2776 3120 3643 80 610 173 32 360 1 150 Nos. 188 65 120 65 Sq.mtrs. Nos. Sq.mtrs. 3120 188 3120 65 55 65 45 22 25 40 43 10 8 1.5 60 4 10 30 2 3000 5% 12.36% 2.00% Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 944450 271810 79040 85860 68640 72025 26200 14104 27760 24960 5465 4800 2440 1730 960 720 3000 1633964 81698 1715662 28200 14521 4994 1254 1932 3120 2873 655 328 2810 3120 3689 80 596 173 36 312 1 943865 274670 81510 86940 68640 71825 26200 14104 28100 24960 5533.5 4800 2384 1730 1080 624 3000 1639966 81998 1721964 187 28050 202800 22560 202800 428160 2172022 52921 43440 3120 187 3120 202800 22440 202800 428040 2178054 52906 43561 2268383 727 44 25 25 94 821 2274521 729 44 25 25 94 823 23 21 Page | 90 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-OVPH models Table No.1.5 . The detail estimates of NHM-OVPH-4000 model Model Structural material Size Dimensions Height Sr. No. Particulars A Cost of Material 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Curtain Clamps Pulley assembly Curtain Rings UV stabilised FRP-Door Sub Total VAT (compulsory) Rate (Rs) 65 55 65 45 22 25 40 43 10 8 1.5 60 4 10 30 2 3000 NHM-OVPH-4000 G.I. Pipes 4080 sq m, 4000 sq. m. 60 m X 68 m 100 m X 40 m Minimum 6.5 m at center 60 m X 68 m 4080 Unit Amount Quantity (Rs) Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Mtrs. Nos. Nos. Nos. Nos. 18761 6375 1704 2484 4080 3822 756 378 3613 4080 4742 106 763 200 40 360 1 5% Total Material Cost B Foundation-civil material C Labour Cost Fabrication Foundation 3 Installation 1 2 D E F G Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head 1219465 350625 110760 111780 89760 95550 30240 16254 36130 32640 7113 6360 3052 2000 1200 720 3000 100 m X 40 m 4000 Amount Quantity (Rs) 18554 6532 1752 2535 4000 3667 832 416 3687 4000 4839 102 718 220 56 240 1 1206010 359260 113880 114075 88000 91675 33280 17888 36870 32000 7258.5 6120 2872 2200 1680 480 3000 2116649 105832 2116549 105827 2222481 2222376 150 Nos. 230 34500 234 35100 64 Sq.mtrs. 4080 261120 4000 256000 120 64 Nos. 230 27600 234 28080 Sq.mtrs. 4080 261120 4000 256000 549840 2806821 67960 56136 540080 2797556 66754 55951 Rs/Sq.mtr 2930918 718 2920261 730 12.36% 2.00% Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System Irrigation System Total Unit Rate Optional Items as per table no 8 Max limit Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 25 88 806 25 88 818 Rs/Sq.mtr 38 26 Page | 91 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-CCPH models Table No.2.1 - The detail estimates of NHM-CCPH -1000 model Model Structural material NHM-CCPH-1000 G.I. Pipes Size 1008 sq m 28 m X 36 m Dimensions 36 m X 28 m Height Sr. No. Particulars A Cost of Material 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Pulley assembly Curtain Rings UV stabilised FRP-Door assembly Exhaust Fan Cellulose Cooling pads-4" Water Circulating System Fogging System Control Head for pad circulation Control Head for Foggers Climate Controller Panel Box Civil Work Brick Wall below fan & Pads Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate b) Irrigation System Irrigation System Total Unit Rate 24 B C 1 2 3 D E F G Optional Items as per table no 8 Max limit Rate (Rs) Minimum 4.5 m at center 28 m X 36 m 1008 Unit Amount Quantity (Rs) 36 m X 28 m 1008 Amount Quantity (Rs) 65 55 65 45 22 25 40 10 8 1.5 60 4 30 2 3000 22000 2300 2700 25 50400 59850 60000 45000 Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Nos. Nos. Nos. Nos. Sq. Mtrs Mtrs. Sq.Mtrs No. No. No. No. 4187 1866 316 684 1008 945 107 589 1008 810 24 231 10 216 2 8 39 26 1008 1 1 1 1 272155 102630 20540 30780 22176 23625 4280 5890 8064 1215 1440 924 300 432 6000 176000 89700 70200 25200 50400 59850 60000 45000 4280 1920 378 748 1008 970 139 639 1008 878 24 218 12 168 2 8 26 34 1008 1 1 1 1 278200 105600 24570 33660 22176 24250 5560 6390 8064 1317 1440 872 360 336 6000 176000 59800 91800 25200 50400 59850 60000 45000 1500 Sq.Mtrs 38 57000 46 69000 1133801 56690 1190491 11400 72 1155845 57792 1213637 10800 5% 150 Nos. 76 68 130 68 Sq.mtrs. Nos. Sq.mtrs. 1008 76 1008 Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 68544 9880 68544 146968 1348859 18165 26977 1394001 1383 25 25 1408 Rs/Sq.mtr 57 12.36% 2% 1008 72 1008 68544 9360 68544 146448 1370885 18101 27418 1416404 1405 25 25 1430 35 Page | 92 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-CCPH models Model Structural material Size Dimensions Height Sr. No. A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C 1 2 3 D E F G Table No.2.2 - The detail estimates of NHM-CCPH -2000 model NHM-CCPH-2000 G.I. Pipes 2016 Sq.mtrs., 2080 Sq.mtrs. 36 m X 56 m 52 m X 40 m Minimum 4.5 m at center Particulars Cost of Material GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Pulley assembly Curtain Rings UV stabilised FRP-Door assembly Exhaust Fan Cellulose Cooling pads-4" Water Circulating System Fogging System Control Head for pad circulation Control Head for Foggers Climate Controller Panel Box Civil Work Brick Wall below fan & Pads Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate b) Irrigation System Irrigation System Total Unit Rate Optional Items as per table no 8 Max limit 36 m X 56 m 2016 52 m X 40 m 2080 Amount Quantity (Rs) Rate (Rs) Unit 65 55 65 45 22 25 40 10 8 1.5 60 4 30 2 3000 22000 2300 2700 25 87150 96600 60000 78750 Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Nos. Nos. Nos. Nos. Sq. Mtrs Mtrs. Sq.Mtrs No. No. No. No. 8380 3331 728 1179 2016 1940 139 907 2016 1248 51 428 24 336 2 14 51 34 2016 1 1 1 1 544700 183205 47320 53055 44352 48500 5560 9070 16128 1872 3060 1712 720 672 6000 308000 117300 91800 50400 87150 96600 60000 78750 8639 3515 881 1333 2080 2058 204 1019 2080 1401 52 410 32 240 2 14 75 50 2080 1 1 1 1 561535 193325 57265 59985 45760 51450 8160 10190 16640 2101.5 3120 1640 960 480 6000 308000 172500 135000 52000 87150 96600 60000 78750 1500 Sq.Mtrs 58 87000 74 111000 1942926 97146 2040072 19200 122 2119612 105981 2225592 18300 Quantity 5% 150 Nos. 128 66 130 66 Sq.mtrs. Nos. Sq.mtrs. 2016 128 2016 Amount (Rs) Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 133056 16640 133056 282752 2342024 34948 46840 2423813 1202 25 25 1227 Rs/Sq.mtr 113 12.36% 2% 2080 122 2080 137280 15860 137280 290420 2534312 35896 50686 2620894 1260 25 25 1285 113 Page | 93 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-CCPH models Table No.2.3 - The detail estimates of NHM-CCPH -3000 model Model NHM-CCPH-3000 Structural material G.I. Pipes Size 3120 Sq.mtrs. 52 m X 60 m Dimensions 60 m X 52 m Height Minimum 4.5 m at center 52 m X 60 m Sr. Rate 3120 Particulars Unit No. (Rs) Amount Quantity A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C 1 2 3 D E F G Cost of Material GI Pipes UV stablised Poly Film GI Gutter Aluminium Profiles Clamps & Accessories Shade Net (Tapenet on roof) Insect Net (on sides) Locking spring High Tensile Nuts & Bolts Self drilling tapping Screws GI Wire Plastic Rope Pulley assembly Curtain Rings UV stabilised FRP-Door assembly Exhaust Fan Cellulose Cooling pads-6" Water Circulating System Fogging System Control Head for pad circulation Control Head for Foggers Climate Controller Panel Box Civil Work Brick Wall below fan & Pads Sub Total VAT (compulsory) Total Material Cost Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost Grand total Unit rate b) Irrigation System Irrigation System Total Unit Rate 65 55 65 45 22 25 40 10 8 1.5 60 4 30 2 Kgs. Sq.mtrs Kgs. Mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs. Sq.mtrs Mtrs. Sq.mtrs. Nos. Kgs. Nos. Nos. 12595 4901 1302 1773 3120 3087 204 1275 3120 1753 80 610 32 720 3000 Nos. 2 22000 3500 2700 25 107100 123900 60000 137813 Nos. Sq. Mtrs Mtrs. Sq.Mtrs No. No. No. No. 22 75 50 3120 1 1 1 1 1500 Sq.Mtrs 83 5% 150 Nos. 172 66 130 66 Sq.mtrs. Nos. Sq.mtrs. 3120 172 3120 Optional Items as per table no 8 Max limit Quantity (Rs) 818675 269555 84630 79785 68640 77175 8160 12750 24960 2629.5 4800 2440 960 1440 6000 484000 262500 135000 78000 107100 123900 60000 137812.5 124500 2975412 148771 3124183 25800 Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 205920 22360 205920 434200 3584183 53667 71684 3709533 1189 25 25 1214 Rs/Sq.mtr 98 12.36% 2% 60 m X 52 m 3120 12611 4956 1359 1837 3120 3112 236 1324 3120 1820 80 596 36 624 2 22 87 58 3120 1 1 1 1 91 168 3120 168 3120 Amount (Rs) 819715 272580 88335 82665 68640 77800 9440 13240 24960 2730 4800 2384 1080 1248 6000 484000 304500 156600 78000 107100 123900 60000 137812.5 136500 3064030 153201 3217231 25200 205920 21840 205920 433680 3676111 53603 73522 3803236 1219 25 25 1244 98 Page | 94 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-CCPH models Sr. No. A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 B C 1 2 3 D E F G Table No.2.4 - The detail estimates of NHM-CCPH -4000 model Model NHM-CCPH-4000 Structural material G.I. Pipes Size 4080 Sq.mtrs., 4000 Sq.mtrs. 68 m X 60 m Dimensions 100 m X 40 m Height Minimum 4.5 m at center 68 m X 60 m 100 m X 40 m Rate Particulars Unit 4080 4000 (Rs) Quantity Amount (Rs) Quantity Amount (Rs) Cost of Material Kgs. 16246 1055990 16183 1051895 65 GI Pipes UV stablised Poly Film Sq.mtrs 6270 344850 6487 356785 55 GI Gutter Kgs. 1819 118235 1934 125710 65 Aluminium Profiles Mtrs. 2306 103770 2534 114030 45 Clamps & Accessories Sq.mtrs. 4080 89760 4000 88000 22 Sq.mtrs. 4095 102375 4074 101850 25 Shade Net (Tapenet on roof) Sq.mtrs. 268 10720 397 15880 40 Insect Net (on sides) Sq.mtrs 1604 16040 1813 18130 10 Locking spring Mtrs. 4080 32640 4000 32000 8 High Tensile Nuts & Bolts Sq.mtrs. 2205 3307.5 2493 3739.5 1.5 Self drilling tapping Screws Nos. 106 6360 102 6120 60 GI Wire Kgs. 763 3052 718 2872 4 Plastic Rope Nos. 40 1200 56 1680 30 Pulley assembly Curtain Rings Nos. 720 1440 480 960 2 UV stabilised FRP-Door Nos. 2 6000 6000 3000 2 assembly Exhaust Fan Nos. 28 616000 28 616000 22000 Sq. Mtrs 99 346500 99 346500 3500 Cellulose Cooling pads-6" Water Circulating System Mtrs. 66 178200 66 178200 2700 Fogging System Sq.Mtrs 4080 102000 4000 100000 25 Control Head for pad circulation No. 1 124425 1 124425 124425 Control Head for Foggers No. 1 137025 1 137025 137025 Climate Controller No. 1 60000 1 60000 60000 Panel Box No. 1 241171.875 1 241171.875 241172 Civil Work Brick Wall below fan Sq.Mtrs 108 162000 140 210000 1500 & Pads Sub Total 3863061 3938973 193153 196949 5% VAT (compulsory) Total Material Cost 4056214 4135922 Nos. 208 31200 200 30000 Foundation-civil material 150 Labour Cost Fabrication Sq.mtrs. 4080 269280 2080 137280 66 Foundation Nos. 208 27040 200 26000 130 Installation Sq.mtrs. 4080 269280 2080 137280 66 Total Labour cost 565600 300560 Total 4653014 4466482 69908 37149 Service Tax on Labour cost 12.36% 93060 89330 Transport cost 2% Grand total 4815983 4592961 Unit rate 1180 1148 Rs/Sq.mtr b) Irrigation System 25 25 Rs/Sq.mtr Irrigation System 25 25 Rs/Sq.mtr Total Unit Rate 1205 1173 Rs/Sq.mtr Opptional Items as per table no 8 max limit Rs/Sq.mtr 89 89 Page | 95 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ¶Éäb÷xÉä]õ½þÉ>ðºÉþSªÉÉ |ÉEòÉ®úÉxÉÖºÉÉ®ú ´É +ÉEòÉ®ú¨ÉÉxÉÉxÉÚºÉÉ®ú iɺÉäSÉ iÉÉÆÊjÉEò {ÉÊ®ú¨ÉÉhÉÉxÉÚºÉÉ®ú ºÉʴɺiÉ®ú JÉSÉÉÇSÉÒ +ÆnùÉVÉ{ÉjÉEä÷ (Estimates)÷ {ÉÖføÒ±É {ÉÉxÉÉ´É®ú Ênù±ÉÒ +ɽäþiÉ. (Table No. 1.1 to 4.5) The detail estimates of NHM-RTNH 5M models Table No. 1.1 - The detail estimates and technical specifications of NHM-RTNH5M-500 model Model Structural material Size Dimensions Height Sr. No. Particulars A 1 2 3 4 5 6 7 8 9 10 Cost of Material GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total Excise VAT NHM-RTNH5M-500 G.I. Pipes 504 sq m 18 m x 28 m Minimum 5.0 m at Center Rate (Rs) Unit 65 25 40 45 45 11 1.5 15 10 3000 Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. 18 m x 28 m 504 Quantity Amount (Rs) 1630 653 313 148 223 324 426 504 504 1 5% Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 179858 150 Nos. 34 5100 40 Sq.mtrs 504 20160 130 Nos. 34 4420 40 Sq.mtrs 504 20160 44740 Total 229698 D Service Tax on Labour cost 12.36% 5530 E Transport cost 2.00% 4594 Grand total F G 105950 16325 12520 6660 10035 3564 639 7560 5040 3000 171293 8565 239821 Unit rate a) Control Head - 500 Rs/Sq.mtr 476 Rs/Sq.mtr 78 b) Irrigation System Rs/Sq.mtr 25 c) Fogging System Rs/Sq.mtr Rs/Sq.mtr 25 Irrigation System Total Unit Rate Optional Items as per table no 8 Max limit Rs/Sq.mtr 128 604 Rs/Sq.mtr 130 Page | 96 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH5M models Table No. 1.2 - The detail estimates and technical specifications of NHM-RTNH5M-1000 model Model Structural material Size Dimensions Height Sr. No. A Particulars NHM-RTNH5M-1000 G.I. Pipes 1008 sq m 36 m x 28 m Minimum 5.0 m at Center Rate (Rs) 36 m x 28 m 1008 Unit Quantity Amount (Rs) Cost of Material 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 3124 203060 25 Sq.mtrs 1305 32625 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 461 18440 43 Sq.mtrs 205 8815 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 390 17550 10 Mtrs. 567 5670 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 745 1117.5 15 Sq.mtrs 1008 15120 10 Sq.mtrs 1008 10080 3000 Nos. 1 3000 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 315477.5 5% 15774 Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 331251 150 Nos. 58 8700 40 Sq.mtrs 1008 40320 130 Nos. 58 7540 40 Sq.mtrs 1008 40320 88180 Total 428131 D Service Tax on Labour cost 12.36% 10899 E Transport cost 2.00% 8563 Grand total F G 447593 Unit rate a) Control Head - 500 Rs/Sq.mtr 444 Rs/Sq.mtr 67 b) Irrigation System Rs/Sq.mtr 25 c) Fogging System 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 117 Total Unit Rate Rs/Sq.mtr 561 Optional Items as per table no 8 Max limit Rs/Sq.mtr 130 Page | 97 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH5M models Table No. 1.3- The detail estimates and technical specifications of NHM-RTNH5M-2000 model Model Structural material Size Dimensions Height Sr. No. Particulars A 1 2 3 4 5 6 7 8 9 10 Cost of Material GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total VAT Rate (Rs) 65 25 40 43 45 10 1.5 15 10 3000 NHM-RTNH5M-2000 G.I. Pipes 2016 sq m 36 m x 56 m 42 m x 48m Minimum 5.0 m at Center 36 m x 56 m 42 m x 48 m 2016 2016 Unit Amount Amount Quantity Quantity (Rs) (Rs) Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. 5924 2565 619 293 606 881 1156 2016 2016 1 5% Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 385060 64125 24760 12599 27270 8810 1734 30240 20160 3000 577758 28888 5942 2573 623 287 623 904 1187 2016 2016 1 606646 386230 64325 24920 12341 28035 9040 1780.5 30240 20160 3000 580072 29003 609075 150 Nos. 107 16050 106 15900 40 Sq.mtrs 2016 80640 2016 80640 130 Nos. 107 13910 106 13780 40 Sq.mtrs 2016 80640 2016 80640 Total 175190 175060 797886 784135 D Service Tax on Labour cost 12.36% 21653 21637.4 E Transport cost 2.00% 15958 15682.7 835497 821455 Grand total F G Unit rate a) Control Head - 500 Rs/Sq.mtr 414 407 Rs/Sq.mtr 54 54 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System Rs/Sq.mtr Rs/Sq.mtr 25 25 Irrigation System 104 104 Total Unit Rate Rs/Sq.mtr 518 511 Optional Items as per table no 8 Max limit Rs/Sq.mtr 113 113 Page | 98 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH5M models Table No. 1.4 - The detail estimates and technical specifications of NHM-RTNH5M-3000 model Model Structural material Size Dimensions Height Sr. No. A Particulars Rate (Rs) NHM-RTNH5M-3000 G.I. Pipes 3024 sq m 42 m x 72 m 48 m x 64m Minimum 5.0 m at Center 42 m x 72 m 48 m x 64m 3024 3072 Unit Amount Amount Quantity Quantity (Rs) (Rs) Cost of Material 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 8727 567255 8874 576810 25 Sq.mtrs 3833 95825 3900 97500 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 759 30360 763 30520 43 Sq.mtrs 362 15566 356 15308 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 833 37485 858 38610 10 Mtrs. 1212 12120 1248 12480 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1590 2385 1638 2457 15 Sq.mtrs 3024 45360 3072 46080 10 Sq.mtrs 3024 30240 3072 30720 3000 Nos. 1 3000 1 3000 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 5% Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 839596 853485 41979.8 42674.25 881576 896159 150 Nos. 154 23100 155 23250 45 Sq.mtrs 3024 136080 3072 138240 130 Nos. 154 20020 155 20150 45 Sq.mtrs 3024 136080 3072 138240 Total 292180 296630 1196856 1216039 D Service Tax on Labour cost 12.36% 36113 36663 E Transport cost 2.00% 23937 24321 1256906 1277024 Grand total F G Unit rate a) Control Head - 500 Rs/Sq.mtr 416 416 Rs/Sq.mtr 44 44 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System 25 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 94 94 Total Unit Rate Rs/Sq.mtr 510 510 Optional Items as per table no 8 Max limit Rs/Sq.mtr 98 98 Page | 99 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH5M models Table No. 1.5 - The detail estimates and technical specifications of NHM-RTNH5M-3000 model Model Structural material Size Dimensions Height Sr. No. NHM-RTNH5M-3000 G.I. Pipes 3024 sq m 54 m x 56 m Minimum 5.0 m at Center 54 m x 56 m 3024 Quantity Amount (Rs) Rate (Rs) Unit 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 8764 569660 25 Sq.mtrs 3848 96200 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 767 30680 43 Sq.mtrs 350 15050 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 865 38925 10 Mtrs. 1258 12580 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1651 2476.5 15 Sq.mtrs 3024 45360 10 Sq.mtrs 3024 30240 3000 Nos. 1 3000 A Particulars Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 844172 5% 42208.575 Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 886380 150 Nos. 152 22800 45 Sq.mtrs 3024 136080 130 Nos. 152 19760 45 Sq.mtrs 3024 136080 291920 Total D Service Tax on Labour cost E Transport cost 1201100 12.36% 36081 2% 24022 Grand total F G 1261203 Unit rate a) Control Head - 500 Rs/Sq.mtr 417 Rs/Sq.mtr 44 b) Irrigation System Rs/Sq.mtr 25 c) Fogging System 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr Total Unit Rate Rs/Sq.mtr 511 Optional Items as per table no 8 Max limit Rs/Sq.mtr 98 94 Page | 100 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH5M models Table No. 1.6 - The detail estimates and technical specifications of NHM-RTNH5M-4000 model Model Structural material Size Dimensions Height Sr. No. A 1 2 3 4 5 6 7 8 9 10 B C Particulars Rate (Rs) NHM-RTNH5M-4000 G.I. Pipes 4032 sq m 4080 sq m 48 m x 84 m 60 m x 68m Minimum 5.0 m at Center 48 m x 84 m 60 m x 68m 4032 4080 Unit Amount Amount Quantity Quantity (Rs) (Rs) Cost of Material GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total VAT Total Material Cost Foundation-civil material Labour Cost 1 Fabrication 2 Foundation 3 Installation 65 25 40 43 45 10 1.5 15 10 3000 Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. 11515 5100 876 419 1056 1536 2016 4032 4032 1 150 Nos. 200 45 130 45 Sq.mtrs Nos. Sq.mtrs 4032 200 4032 5% Total Labour cost Total D E Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head - 500 b) Irrigation System F 12.36% 2% 748475 127500 35040 18017 47520 15360 3024 60480 40320 3000 1098736 54936.8 1153673 30000 11681 5175 884 406 1097 1595 2094 4080 4080 1 181440 26000 181440 388880 1572553 48066 31451 4080 200 4080 200 759265 129375 35360 17458 49365 15950 3141 61200 40800 3000 1114914 55745.7 1170660 30000 183600 26000 183600 393200 1593860 48600 31877 Rs/Sq.mtr Rs/Sq.mtr 1652069 410 38 1674336 410 38 Rs/Sq.mtr 25 25 25 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 88 88 Total Unit Rate Rs/Sq.mtr 498 498 89 89 c) Fogging System Optional Items as per table no 8 G Max limit Page | 101 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH5M models Table No. 1.7- The detail estimates and technical specifications of NHM-RTNH5M-4000 model Model Structural material NHM-RTNH5M-4000 G.I. Pipes 4032 sq m 4056 sq m 72 m x 56 m 78 m x 52m Minimum 5.0 m at Center 72 m x 56 m Size Dimensions Height Sr. No. Particulars Cost of Material 1 2 3 4 5 6 7 8 9 10 GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total VAT Total Material Cost Foundation-civil material Labour Cost 1 Fabrication 2 Foundation 3 Installation 65 25 40 43 45 10 1.5 15 10 3000 Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. 11605 5130 914 406 1124 1635 2147 4032 4032 1 150 Nos. 197 45 130 45 Sq.mtrs Nos. Sq.mtrs 4032 197 4032 5% Total Labour cost Total D E Service Tax on Labour cost Transport cost 12.36% 2.00% Grand total F G 4032 Unit Quantity A B C Rate (Rs) 78 m x 52m 4056 Amount (Rs) Quantity 754325 128250 36560 17458 50580 16350 3220.5 60480 40320 3000 1110544 55527 1166071 29550 11703 5168 941 413 1149 1672 2194 4056 4056 1 181440 25610 181440 388490 1584111 48017 31682 4056 198 4056 198 Amount (Rs) 760695 129200 37640 17759 51705 16720 3291 60840 40560 3000 1121410 56071 1177481 29700 182520 25740 182520 390780 1597961 48300 31959 1663810 1678220 Unit rate a) Control Head - 500 Rs/Sq.mtr 413 414 Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System 25 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 88 88 Total Unit Rate Rs/Sq.mtr 501 502 Optional Items as per table no 8 Max limit Rs/Sq.mtr 89 89 Page | 102 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH4M models Table No. 2.1 - The detail estimates and technical specifications of NHM-RTNH4M-500 model Model Structural material Size Dimensions Height Sr. No. Particulars A 1 2 3 4 5 6 7 8 9 10 Cost of Material GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total Excise VAT Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost Total D Service Tax on Labour cost E Transport cost Grand total Unit rate a) Control Head - 500 b) Irrigation System F c) Fogging System Irrigation System Total Unit Rate Optional Items as per table no 8 Max G limit NHM-RTNH4M-500 G.I. Pipes 504 sq m 18 m x 28 m Minimum 4.0 m at Center 18 m x 28 m 504 Quantity Amount (Rs) Rate (Rs) Unit 65 25 40 45 45 11 1.5 15 10 3000 Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. 1285 653 206 148 208 303 397 504 504 1 150 Nos. 34 40 130 40 Sq.mtrs Nos. Sq.mtrs 504 34 504 5% 83525 16325 8240 6660 9360 3333 595.5 7560 5040 3000 143638.5 7182 150820 5100 Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr Rs/Sq.mtr 20160 4420 20160 44740 200660 5530 4013 210203 417 78 25 25 128 545 Rs/Sq.mtr 130 12.36% 2.00% Page | 103 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH4M models Table No. 2.2 - The detail estimates and technical specifications of NHM-RTNH4M-1000 model Model Structural material Size Dimensions Height Sr. No. A Particulars Rate (Rs) NHM-RTNH4M-1000 G.I. Pipes 1008 sq m 36 m x 28 m Minimum 4.0 m at Center 36 m x 28 m 1008 Unit Quantity Amount (Rs) Cost of Material 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 2448 159120 25 Sq.mtrs 1305 32625 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 320 12800 43 Sq.mtrs 205 8815 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 364 16380 10 Mtrs. 530 5300 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 695 1042.5 15 Sq.mtrs 1008 15120 10 Sq.mtrs 1008 10080 3000 Nos. 1 3000 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 264282.5 5% 13214 Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 277497 150 Nos. 58 8700 40 Sq.mtrs 1008 40320 130 Nos. 58 7540 40 Sq.mtrs 1008 40320 88180 Total 374377 D Service Tax on Labour cost 12.36% 10899 E Transport cost 2.00% 7488 Grand total F G 392763 Unit rate a) Control Head – 500 Rs/Sq.mtr 390 Rs/Sq.mtr 67 b) Irrigation System Rs/Sq.mtr 25 c) Fogging System 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 117 Total Unit Rate Rs/Sq.mtr 507 Optional Items as per table no 8 Max limit Rs/Sq.mtr 130 Page | 104 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH4M models Table No. 2.3 - The detail estimates and technical specifications of NHM-RTNH4M-2000 model Model Structural material Size Dimensions Height Sr. No. A Particulars Rate (Rs) NHM-RTNH4M-2000 G.I. Pipes 2016 sq m 36 m x 56 m 42 m x 48m Minimum 4.0 m at Center 36 m x 56 m 2016 Unit Amount Quantity (Rs) 42 m x 48 m 2016 Amount Quantity (Rs) Cost of Material 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 4658 302770 4666 303290 25 Sq.mtrs 2565 64125 2573 64325 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 408 16320 421 16840 43 Sq.mtrs 293 12599 287 12341 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 569 25605 583 26235 10 Mtrs. 827 8270 848 8480 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1086 1629 1113 1669.5 15 Sq.mtrs 2016 30240 2016 30240 10 Sq.mtrs 2016 20160 2016 20160 3000 Nos. 1 3000 1 3000 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 5% Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 484718 486581 24236 29003 508954 515584 150 Nos. 107 16050 106 15900 40 Sq.mtrs 2016 80640 2016 80640 130 Nos. 107 13910 106 13780 40 Sq.mtrs 2016 80640 2016 80640 Total 175190 175060 700194 690644 D Service Tax on Labour cost 12.36% 21653 21637.4 E Transport cost 2.00% 14004 13812.9 735851 726094 Grand total F G Unit rate a) Control Head - 500 Rs/Sq.mtr 365 360 Rs/Sq.mtr 54 54 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System 25 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 104 104 Total Unit Rate Rs/Sq.mtr 469 464 Optional Items as per table no 8 Max limit Rs/Sq.mtr 113 113 Page | 105 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH4M models Table No. 2.4 - The detail estimates and technical specifications of NHM-RTNH4M-3000 model Model Structural material Size Dimensions Height Sr. No . A Rate (Rs) Particulars NHM-RTNH4M-3000 G.I. Pipes 3024 sq m 42 m x 72 m 48 m x 64m Minimum 4.0 m at Center 42 m x 72 m 3024 Unit Amount Quantity (Rs) 48 m x 64m 3072 Amount Quantity (Rs) Cost of Material 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 6863 446095 6972 453180 25 Sq.mtrs 3833 95825 3900 97500 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 496 19840 509 20360 43 Sq.mtrs 362 15566 356 15308 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 784 35280 806 36270 10 Mtrs. 1140 11400 1173 11730 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1496 2244 1539 2308.5 15 Sq.mtrs 3024 45360 3072 46080 10 Sq.mtrs 3024 30240 3072 30720 3000 Nos. 1 3000 1 3000 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 5% Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 704850 716456.5 35242.5 35822.825 740092.5 752279.33 150 Nos. 154 23100 155 23250 45 Sq.mtrs 3024 136080 3072 138240 130 Nos. 154 20020 155 20150 45 Sq.mtrs 3024 136080 3072 138240 Total 292180 296630 1055372.5 1072159.3 D Service Tax on Labour cost 12.36% 36113 36663 E Transport cost Grand total Unit rate a) Control Head - 500 2.00% Rs/Sq.mtr 21107 1112593 368 21443 1130266 368 Rs/Sq.mtr 44 44 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System 25 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 94 94 Total Unit Rate Rs/Sq.mtr 462 462 Optional Items as per table no 8 Max limit Rs/Sq.mtr 98 98 F G Page | 106 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH4M models Table No. 2.5 - The detail estimates and technical specifications of NHM-RTNH4M-3000 model Model Structural material Size Dimensions Height Sr. No. NHM-RTNH4M-3000 G.I. Pipes 3024 sq m 54 m x 56 m Minimum 4.0 m at Center 54 m x 56 m 3024 Quantity Amount (Rs) Rate (Rs) Unit 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 6879 447135 25 Sq.mtrs 3848 96200 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 521 20840 43 Sq.mtrs 350 15050 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 812 36540 10 Mtrs. 1181 11810 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1551 2326.5 15 Sq.mtrs 3024 45360 10 Sq.mtrs 3024 30240 3000 Nos. 1 3000 A Particulars Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 708502 5% 35425.075 Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost 743927 150 Nos. 152 22800 45 Sq.mtrs 3024 136080 130 Nos. 152 19760 45 Sq.mtrs 3024 136080 291920 Total D Service Tax on Labour cost E Transport cost 1058647 12.36% 36081 2% 21173 Grand total F G 1115901 Unit rate a) Control Head - 500 Rs/Sq.mtr 369 Rs/Sq.mtr 44 b) Irrigation System Rs/Sq.mtr 25 c) Fogging System 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr Total Unit Rate Rs/Sq.mtr 463 Optional Items as per table no 8 Max limit Rs/Sq.mtr 98 94 Page | 107 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Table No. 2.6 - The detail estimates and technical specifications of NHM-RTNH4M-4000 model Model Structural material Size Dimensions Height Sr. No. Particulars A GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total VAT Total Material Cost Foundation-civil material Labour Cost 1 Fabrication 2 Foundation 3 Installation 65 25 Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. 9055 5100 572 419 994 1446 1898 4032 4032 1 150 Nos. 200 45 130 45 Sq.mtrs Nos. Sq.mtrs 4032 200 4032 40 43 45 10 1.5 15 10 3000 5% Total Labour cost Total D E F G 60 m x 68m 4080 Quan Amount tity (Rs) Cost of Material 1 2 3 4 5 6 7 8 9 10 B C Rate (Rs) NHM-RTNH4M-4000 G.I. Pipes 4032 sq m 4080 sq m 48 m x 84 m 60 m x 68m Minimum 4.0 m at Center 48 m x 84 m 4032 Unit Quan Amount tity (Rs) Service Tax on Labour cost Transport cost Grand total Unit rate a) Control Head - 500 12.36% 2% 588575 127500 22880 18017 44730 14460 2847 60480 40320 3000 922809 46140.45 968949 30000 9172 5175 597 406 1031 1500 1969 4080 4080 1 181440 26000 181440 388880 1387829 48066 27757 4080 200 4080 200 596180 129375 23880 17458 46395 15000 2953.5 61200 40800 3000 936241 46812 983053 30000 183600 26000 183600 393200 1406254 48600 28125 Rs/Sq.mtr 1463652 363 1482978 363 Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System 25 25 Irrigation System Rs/Sq.mtr Rs/Sq.mtr 88 88 Total Unit Rate Rs/Sq.mtr 451 451 Optional Items as per table no 8 Max limit Rs/Sq.mtr 89 89 Page | 108 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-RTNH4M models Table No. 2.7- The detail estimates and technical specifications of NHM-RTNH4M-4000 model Model Structural material Size Dimensions Height Sr. No. A Rate (Rs) GI Pipes Shade Net (Tapenet on roof) Insect Net (on sides) Laminated woven film (apron) Aluminium Profiles Locking spring Self drilling tapping Screws Clamps & Accessories High Tensile Nuts & Bolts UV stabilised FRP-Door Sub Total VAT Total Material Cost Foundation-civil material Labour Cost 1 Fabrication 2 Foundation 3 Installation 65 25 40 43 45 10 1.5 15 10 3000 Kgs. Sq.mtrs Sq.mtrs Sq.mtrs Mtrs. Mtrs. Nos. Sq.mtrs Sq.mtrs Nos. Service Tax on Labour cost Transport cost Quanti ty Amount (Rs) 932377 46619 978995.85 29550 Nos. 197 45 130 45 Sq.mtrs Nos. Sq.mtrs 4032 197 4032 12.36% 2.00% 181440 25610 181440 388490 1397035.85 48017 27941 9172 5168 660 413 1078 1569 2059 4056 4056 1 596180 129200 26400 17759 48510 15690 3088.5 60840 40560 3000 198 941227.5 47061 988288.875 29700 4056 198 4056 182520 25740 182520 390780 1408768.875 48300 28175 1472994 1485245 Unit rate a) Control Head - 500 Rs/Sq.mtr 365 366 Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System Rs/Sq.mtr Rs/Sq.mtr 25 25 88 88 Rs/Sq.mtr 453 454 89 89 Irrigation System G 591565 128250 25400 17458 47520 15360 3024 60480 40320 3000 150 Grand total F 9101 5130 635 406 1056 1536 2016 4032 4032 1 5% Total Labour cost Total D E 78 m x 52m 4056 Cost of Material 1 2 3 4 5 6 7 8 9 10 B C Particulars NHM-RTNH4M-4000 G.I. Pipes 4032 sq m 4056 sq m 72 m x 56 m 78 m x 52m Minimum 4.0 m at Center 72 m x 56 m 4032 Unit Quan Amount (Rs) tity Total Unit Rate Opetional Items as per table no 8 Max limit Page | 109 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH4M models Table No. 3.1 - The detail estimates and technical specifications of NHM-FTNH4M-1000 model Model Structural material Size Dimensions Height Sr. No. NHM-FTNH4M-1000 G.I. Pipes 1040 sq m, 1088 sq m 20 m x 52 m, 32m X 34m Minimum 4.0 m Unit 1 GI Pipes 65 Kgs. 2245 2 Shade Net (Tapenet on roof) 25 Sq.mtrs 3 Insect Net (on sides) 40 4 Laminated woven film (apron) Particulars 32m X 34m 1088 Quantity Amount (Rs) 145925 2269 147485 806 20150 882 22050 Sq.mtrs 522 20880 476 19040 43 Sq.mtrs 217 9331 198 8514 5 Aluminium Profiles 45 Mtrs. 358 16110 384 17280 6 Locking spring 10 Mtrs. 520 5200 558 5580 7 Self drilling tapping Screws 1.5 Nos. 715 1072.5 768 1152 8 Clamps & Accessories 10 Sq.mtrs 1040 10400 1088 10880 5 3000 Sq.mtrs Nos. 1040 1 5200 3000 1088 1 5440 3000 A Quantity Sub Total VAT Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost Total D Service Tax on Labour cost E Transport cost 5% 237268.5 11863 240421 12021 150 Nos. 123 249132 18450 252442 18900 35 120 35 Sq.mtrs Nos. Sq.mtrs 1040 123 1040 12.36% 2.00% Grand total F Amount (Rs) Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door G 20 m x 52 m 1040 Rate (Rs) 36400 14760 36400 87560 355142 10822 7103 126 1088 126 1088 38080 15120 38080 91280 362622 11282 7252 373067 381157 Unit rate a) Control Head – 500 Rs/Sq.mtr 359 350 Rs/Sq.mtr 67 67 b) Irrigation System Rs/Sq.mtr 25 25 c) Fogging System Rs/Sq.mtr Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 117 476 25 117 467 Rs/Sq.mtr 130 130 Optional Items as per table no 8 Max limit Page | 110 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH4M models Table No. 3.2 - The detail estimates and technical specifications of NHM-FTNH4M-2000 model Model Structural material NHM-FTNH4M-2000 G.I. Pipes Size 2048 sq m,2024 sq m 32 m x 64 m 44 m x 46m Minimum 4.0 m Dimensions Height Sr. No. Particulars Rate (Rs) Unit 32 m x 64 m 2048 44 m x 46m 2024 Quantity Amount (Rs) Quantity Amount (Rs) A Cost of Material 1 GI Pipes 65 Kgs. 3929 255385 3852 250380 2 Shade Net (Tapenet on roof) 25 Sq.mtrs 1764 44100 1764 44100 3 Insect Net (on sides) 40 Sq.mtrs 703 28120 658 26320 4 Laminated woven film (apron) 43 Sq.mtrs 293 12599 274 11782 5 Aluminium Profiles 45 Mtrs. 648 29160 655 29475 6 Locking spring 10 Mtrs. 942 9420 952 9520 7 Self drilling tapping Screws 1.5 Nos. 1296 1944 1309 1963.5 8 Clamps & Accessories 15 Sq.mtrs 2048 30720 2024 30360 9 High Tensile Nuts & Bolts 10 Sq.mtrs 2048 20480 2024 20240 10 UV stabilised FRP-Door Sub Total 3000 Nos. 1 3000 1 3000 VAT 5% Total Material Cost B C 1 2 3 D E Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost G 427141 21746 29003 456674 456144 150 Nos. 196 29400 196 29400 35 130 35 Sq.mtrs Nos. Sq.mtrs 2048 196 2048 71680 25480 71680 168840 654914 20869 13098 2024 196 2024 70840 25480 80640 176960 633104 21872 12662 12.36% 2.00% Grand total F 434928 688881 667638 Unit rate a) Control Head – 500 Rs/Sq.mtr 336 330 Rs/Sq.mtr 54 54 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 25 104 440 25 25 104 434 Rs/Sq.mtr 113 113 Optional Items as per table no 8 Max limit Rs/Sq.mtr Page | 111 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH4M-3000 models Table No. 3.3 - The detail estimates and technical specifications of NHM-FTNH4M-3000 model Model Structural material Size NHM-FTNH4M-3000 G.I. Pipes 3016 sq m,3040 sq m 52 m x 58 m 40 m x 76 m Minimum 4.0 m Dimensions Height Sr. No. Particulars Rate (Rs) Unit 52 m x 58 m 3016 Quantity 40 m x 76 m 3040 Amount (Rs) Quantity Amount (Rs) A Cost of Material 1 GI Pipes 65 Kgs. 5464 355160 5542 360230 2 Shade Net (Tapenet on roof) 25 Sq.mtrs 2722 68050 2722 68050 3 Insect Net (on sides) 40 Sq.mtrs 809 32360 854 34160 4 Laminated woven film (apron) 43 Sq.mtrs 337 14491 356 15308 5 Aluminium Profiles 45 Mtrs. 936 42120 930 41850 6 Locking spring 10 Mtrs. 1362 13620 1352 13520 7 Self drilling tapping Screws 1.5 Nos. 1872 2808 1859 2788.5 8 Clamps & Accessories 15 Sq.mtrs 3016 45240 3040 45600 9 High Tensile Nuts & Bolts 10 Sq.mtrs 3016 30160 3040 30400 10 UV stabilised FRP-Door Sub Total 3000 Nos. 1 3000 1 3000 VAT 5% Total Material Cost B C 1 2 3 D E Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost G 614907 30350.45 30745.33 637359 645652 150 Nos. 262 39300 262 39300 35 130 35 Sq.mtrs Nos. Sq.mtrs 3016 262 3016 105560 34060 105560 245180 921839 30304 18437 3040 262 3040 106400 34060 106400 246860 931812 30512 18636 12.36% 2.00% Grand total F 607009 970580 980960 Unit rate a) Control Head - 500 Rs/Sq.mtr 322 323 Rs/Sq.mtr 44 44 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 25 94 416 25 25 94 417 Rs/Sq.mtr 98 98 Optional Items as per table no 8 Max limit Rs/Sq.mtr Page | 112 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH4M models Table No. 3.4 - The detail estimates and technical specifications of NHM-FTNH4M-4000 model Model Structural material NHM-FTNH4M-4000 G.I. Pipes 4000 sq m 4096 sq m 40 m x 100 m 64 m x 64 m Minimum 4.0 m Size Dimensions Height Sr. No. 40 m x 100 m 4000 Amount Quantity (Rs) 64 m x 64 m 4096 Amount Quantity (Rs) Rate (Rs) Unit 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 7139 464035 7186 467090 25 Sq.mtrs 3629 90725 3780 94500 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 1036 41440 945 37800 43 Sq.mtrs 432 18576 394 16942 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 1194 53730 1246 56070 10 Mtrs. 1736 17360 1813 18130 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 2387 3580.5 2493 3739.5 15 Sq.mtrs 4000 60000 4096 61440 10 Sq.mtrs 4000 40000 4096 40960 3000 Nos. 1 3000 1 3000 A Particulars Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost Total D Service Tax on Labour cost E Transport cost 792447 799672 5% 39622.33 39983.58 150 Nos. 326 832069 48900 839655 49800 35 130 35 Sq.mtrs Nos. Sq.mtrs 4000 326 4000 12.36% 2.00% Grand total F G 140000 42380 140000 322380 1203349 39846 24067 332 4096 332 4096 143360 43160 143360 329880 1219335 40773 24387 1267262 1284495 Unit rate a) Control Head - 500 Rs/Sq.mtr 317 314 Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 25 88 405 25 25 88 402 Rs/Sq.mtr 89 89 Optional Items as per table no 8 Max limit Rs/Sq.mtr Page | 113 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH3.25M models Table No. 4.1 - The detail estimates and technical specifications of NHM-FTNH3.25M-1000 model Model Structural material Size Dimensions Height Sr. No. A NHM-FTNH3.25M-1000 G.I. Pipes 1012 sq m 22 m x 46 m Minimum 3.25 m Unit 1 GI Pipes 65 Kgs. 1428 92820 2 Shade Net (Tapenet on roof) 25 Sq.mtrs 903 22575 3 Insect Net (on sides) 40 Sq.mtrs 425 17000 4 Laminated woven film (apron) 43 Sq.mtrs 213 9159 5 Aluminium Profiles 45 Mtrs. 285 12825 6 Locking spring 10 Mtrs. 414 4140 7 Self drilling tapping Screws 1.5 Nos. 544 816 8 Clamps & Accessories 10 Sq.mtrs 1012 10120 5 3000 Sq.mtrs Nos. 1012 1 5060 3000 Particulars Quantity Sub Total VAT Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost Total D Service Tax on Labour cost E Transport cost 5% 177515 8876 150 Nos. 98 186391 14700 35 120 35 Sq.mtrs Nos. Sq.mtrs 1012 98 1012 12.36% 2.00% Grand total G Amount (Rs) Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door F 22 m x 46 m 1012 Rate (Rs) 35420 11760 35420 82600 283691 10209 5674 299574 Unit rate a) Control Head – 500 Rs/Sq.mtr 296 Rs/Sq.mtr 67 b) Irrigation System Rs/Sq.mtr 25 c) Fogging System Rs/Sq.mtr Irrigation System Total Unit Rate Rs/Sq.mtr Optional Items as per table no 8 Max limit Rs/Sq.mtr 25 117 413 130 Rs/Sq.mtr Page | 114 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH3.25M models Table No. 4.2 - The detail estimates and technical specifications of NHM-FTNH3.25M-2000 model Model Structural material NHM-FTNH 3.25M-2000 G.I. Pipes Size 2080 sq m 40 m x 52 m Dimensions Height Sr. No. Minimum 3.25 m Particulars Rate (Rs) Unit 40 m x 52 m 2080 Quantity Amount (Rs) A Cost of Material 1 GI Pipes 65 Kgs. 2493 162045 2 Shade Net (Tapenet on roof) 25 Sq.mtrs 2058 51450 3 Insect Net (on sides) 40 Sq.mtrs 576 23040 4 Laminated woven film (apron) 43 Sq.mtrs 288 12384 5 Aluminium Profiles 45 Mtrs. 509 22905 6 Locking spring 10 Mtrs. 741 7410 7 Self drilling tapping Screws 1.5 Nos. 972 1458 8 Clamps & Accessories 15 Sq.mtrs 2080 31200 9 High Tensile Nuts & Bolts 10 Sq.mtrs 2080 20800 10 UV stabilised FRP-Door Sub Total 3000 Nos. 1 3000 VAT 335692 5% 16785 Total Material Cost B C 1 2 3 D E Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost 352477 150 Nos. 153 22950 35 130 35 Sq.mtrs Nos. Sq.mtrs 2080 153 2080 72800 19890 72800 165490 540917 20455 10818 12.36% 2.00% Grand total F G 572189 Unit rate a) Control Head - 500 Rs/Sq.mtr 275 Rs/Sq.mtr 54 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Optional Items as per table no 8 Max limit Rs/Sq.mtr 25 25 104 379 113 Rs/Sq.mtr Rs/Sq.mtr Page | 115 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH3.25M-3000 models Table No. 4.3 - The detail estimates and technical specifications of NHM-FTNH3.25M-3000 model Model Structural material Size NHM-FTNH3.25M-3000 G.I. Pipes 3016 sq m,3040 sq m 52 m x 58 m 40 m x 76 m Minimum 3.25 m Dimensions Height Sr. No. Particulars Rate (Rs) Unit 52 m x 58 m 3016 40 m x 76 m 3040 Quantity Amount (Rs) Quantity Amount (Rs) A Cost of Material 1 GI Pipes 65 Kgs. 3399 220935 3472 225680 2 Shade Net (Tapenet on roof) 25 Sq.mtrs 3080 77000 3066 76650 3 Insect Net (on sides) 40 Sq.mtrs 690 27600 728 29120 4 Laminated woven film (apron) 43 Sq.mtrs 345 14835 364 15652 5 Aluminium Profiles 45 Mtrs. 701 31545 694 31230 6 Locking spring 10 Mtrs. 1019 10190 1010 10100 7 Self drilling tapping Screws 1.5 Nos. 1338 2007 1325 1987.5 8 Clamps & Accessories 15 Sq.mtrs 3016 45240 3040 45600 9 High Tensile Nuts & Bolts 10 Sq.mtrs 3016 30160 3040 30400 10 UV stabilised FRP-Door Sub Total 3000 Nos. 1 3000 1 3000 VAT 5% Total Material Cost B C 1 2 3 D E Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost G 469420 23125.6 23470.98 485638 492890 150 Nos. 198 29700 205 30750 35 130 35 Sq.mtrs Nos. Sq.mtrs 3016 198 3016 105560 25740 105560 236860 752198 29276 15044 3040 205 3040 106400 26650 106400 239450 763090 29596 15262 12.36% 2.00% Grand total F 462512 796517 807948 Unit rate a) Control Head - 500 Rs/Sq.mtr 264 266 Rs/Sq.mtr 44 44 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 25 94 358 25 25 94 360 Rs/Sq.mtr 98 98 Optional Items as per table no 8 Max limit Rs/Sq.mtr Page | 116 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH3.25M models Table No. 4.4 - The detail estimates and technical specifications of NHM-FTNH3.25M-4000 model Model Structural material NHM-FTNH3.25M-4000 G.I. Pipes 4000 sq m 4096 sq m 40 m x 100 m 64 m x 64 m Minimum 3.25 m Size Dimensions Height Sr. No. 40 m x 100 m 4000 Amount Quantity (Rs) 64 m x 64 m 4096 Amount Quantity (Rs) Rate (Rs) Unit 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 4452 289380 4418 287170 25 Sq.mtrs 4074 101850 4270 106750 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 879 35160 803 32120 43 Sq.mtrs 439 18877 402 17286 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 879 39555 919 41355 10 Mtrs. 1278 12780 1336 13360 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1678 2517 1754 2631 15 Sq.mtrs 4000 60000 4096 61440 10 Sq.mtrs 4000 40000 4096 40960 3000 Nos. 1 3000 1 3000 A Particulars Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT Total Material Cost B Foundation-civil material C Labour Cost 1 Fabrication 2 Foundation 3 Installation Total Labour cost Total D Service Tax on Labour cost E Transport cost 603119 606072 5% 30155.95 30303.6 150 Nos. 257 633275 38550 636376 37050 35 130 35 Sq.mtrs Nos. Sq.mtrs 4000 257 4000 12.36% 2.00% Grand total F G 140000 33410 140000 313410 985235 38737 19705 247 4096 247 4096 143360 32110 143360 318830 992256 39407 19845 1043677 1051508 Unit rate a) Control Head – 500 Rs/Sq.mtr 261 257 Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 25 88 349 25 25 88 345 Rs/Sq.mtr 89 89 Optional Items as per table no 8 Max limit Rs/Sq.mtr Page | 117 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The detail estimates of NHM-FTNH3.25M models Table No. 4.5 - The detail estimates and technical specifications of NHM-FTNH3.25M-4000 model Model Structural material NHM-FTNH3.25M-4000 G.I. Pipes 4048 sq m 4060 sq m 46 m x 88 m 58 m x 70 m Minimum 3.25 m Size Dimensions Height Sr. No. 46 m x 88 m 4048 Amount Quantity (Rs) 58 m x 70 m 4060 Amount Quantity (Rs) Rate (Rs) Unit 1 GI Pipes 2 Shade Net (Tapenet on roof) 65 Kgs. 4435 288275 4390 285350 25 Sq.mtrs 4165 104125 4221 105525 3 Insect Net (on sides) 4 Laminated woven film (apron) 40 Sq.mtrs 841 33640 803 32120 43 Sq.mtrs 421 18103 402 17286 5 Aluminium Profiles 6 Locking spring 45 Mtrs. 892 40140 905 40725 10 Mtrs. 1298 12980 1317 13170 7 Self drilling tapping Screws 8 Clamps & Accessories 1.5 Nos. 1703 2554.5 1728 2592 15 Sq.mtrs 4048 60720 4060 60900 10 Sq.mtrs 4048 40480 4060 40600 3000 Nos. 1 3000 1 3000 A Particulars Cost of Material 9 High Tensile Nuts & Bolts 10 UV stabilised FRP-Door Sub Total VAT 5% Total Material Cost B C 1 2 3 D E Foundation-civil material Labour Cost Fabrication Foundation Installation Total Labour cost Total Service Tax on Labour cost Transport cost G 601268 30200.88 30063.4 634218 631331 150 Nos. 252 37800 246 36900 35 130 35 Sq.mtrs Nos. Sq.mtrs 4048 252 4048 141680 32760 141680 316120 988138 39072 19763 4060 246 4060 142100 31980 142100 316180 984411 39080 19688 12.36% 2.00% Grand total F 604018 1046974 1043179 Unit rate a) Control Head - 500 Rs/Sq.mtr 259 257 Rs/Sq.mtr 38 38 b) Irrigation System Rs/Sq.mtr c) Fogging System Irrigation System Total Unit Rate Rs/Sq.mtr Rs/Sq.mtr 25 25 88 347 25 25 88 345 Rs/Sq.mtr 89 89 Optional Items as per table no 8 Max limit Rs/Sq.mtr Page | 118 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ANNEX-4 Maximum rates per unit area of Polyhouse /ShadeNet house The maximum rates per unit area of polyhouse of different types and modeles +)½þÊ®úiÉMÉÞ½þ ¤ÉÉ¤É ¨ÉÉìbä÷±ÉSÉÉ |ÉEòÉ®ú BEÚòhÉ IÉäjÉ (SÉÉè.¨ÉÒ.) ¨ÉÉìbä÷±ÉxÉÖºÉÉ®ú ½þÊ®úiÉMÉÞ½þÉSÉÉ +ÉEòÉ®ú (¯ÆûnùÒ x ±ÉÉƤÉÒ) (¨ÉÒ.) |ÉÊiÉ SÉÉè.¨ÉÒ. JÉSÉÇ (¯û.) (¨ÉÉ{ÉnÆùb÷) NHM-OVPH–500 560 20x 28 935 1008 28x 36 884 1008 36x 28 895 (näùªÉ- 890) 2016 36 x 56 848 2080 52 x 40 824 3120 52 x 60 821 3120 60x 52 823 4080 60x 68 806 4000 100X 40 818 1008 28 x 36 1408 1008 36 x 28 1430 2016 36 x 56 1227 2080 52 x 40 1285 3120 52 x 60 1214 3120 60 x 52 1244 4080 68 x 60 1205 4000 100x 40 1173 NHM-OVPH–1000 हरितगह ृ (OVPH) NHM-OVPH–2000 NHM-OVPH–3000 NHM-OVPH–4000 NHM-CCPH -1000 हरितगह ृ NHM-CCPH -2000 (CCPH) NHM-CCPH -3000 NHM-CCPH -4000 Page | 119 E:\2014-15\guideline\GUIDELINE 2014-15 PC. The maximum rates per unit area of Shadenet house of different types and modeles ¤É) शेडनेटहाऊस ¤ÉÉ¤É शेडनेटहाऊस (Round Type) 5मी.उं ची शेडनेटहाऊस (Round Type) 4 मी. उं ची ¨ÉÉìbä÷±ÉSÉÉ |ÉEòÉ®ú BEÚòhÉ IÉäjÉ (SÉÉè.¨ÉÒ.) NHM-RTNH5M-500 NHM-RTNH5M-1000 504 1008 NHM-RTNH5M-2000 2016 NHM-RTNH5M-3000 NHM-RTNH4M-500 3024 3072 3024 4032 4080 4032 4056 504 NHM-RTNH4M-1000 1008 NHM-RTNH4M-2000 2016 NHM-RTNH5M-4000 NHM-RTNH4M-3000 NHM-RTNH4M-4000 NHM-FTNH4M-1000 शेडनेटहाऊस (Flat Type) 4 मी. उं ची NHM-FTNH4M-2000 NHM-FTNH4M-3000 NHM-FTNH4M-4000 शेडनेटहाऊस (Flat Type)३.२५ NHM-FTNH 3.25M-1000 NHM-FTNH3.25M -2000 NHM-FTN3000 मीटि उं ची NHM-FTNH3.25M -4000 3024 3072 3024 4080 4032 4056 1040 1088 2048 2024 3016 3040 4000 4096 1012 2080 3016 3040 4000 4096 4048 4060 ¨ÉÉìbä÷±ÉxÉÖºÉÉ®ú ¶Éäb÷xÉä]õ½þÉ>ðºÉ +ÉEòÉ®ú (¯ÆûnùÒ x ±ÉÉƤÉÒ) (¨ÉÒ.) |ÉÊiÉ SÉÉè.¨ÉÒ. JÉSÉÇ (¯û.) (¨ÉÉ{ÉnÆùb÷) 18 x28 36 x 28 36 x 56 42 x 48 42 x 72 48 x 64 54 x 56 48 x 84 60 x 68 72 x 56 78 x 52 18 x28 604 561 518 511 510 510 511 498 498 501 502 545 36 x 28 36 x 56 42 x 48 42 x 72 48 x 64 54 x 56 60 x 68 72 x 56 78 x 52 20 x 52 32 x34 32 x 64 44 x46 52 x 58 40 x 76 40 x 100 64 x 64 22 x 46 40 x 52 52 x 58 40 x 76 40 x 100 64 x 64 46 x 48 58 x 70 507 469 464 462 462 463 451 453 454 476 467 440 434 416 417 405 402 413 379 358 360 349 345 347 345 Page | 120 E:\2014-15\guideline\GUIDELINE 2014-15 PC. ANNEX-5 Application Cum Company Profile for Registration for Polyhouseand Nethouse Scheme for the Year 2015-16 1 Name of the Company for manufacture/supplier 2 Date of commencement of production/supply 3 Address of Registered Head Office 4 Type of Organisation 5 Details of competent authority Proprietary / Partnership / Pvt. Limited / Public Limited /Any other (Pl specify)_________________ Designation Name company: (a) Details of Chairman/CEO/MD or the authorized Person/Director from the Board of Directors for the private and public ltd (b) Details of all the partners for Partnership firm/company (such as Chairman/CEO/ MD/Director/Par tner/ Proprietor) Mobile No. 1 2 3 4 (c)Details of Proprietor for Proprietorship firm/company 5 (use separate sheet if required) 6 7 8 9 Page | 121 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 6 SSI Registration No.& Date of issue 7 VAT TIN No. 8 Service Tax Registration No. (If applicable) 9 PAN No. 10 Web site (If applicable) 11 Details of Technical Persons in Service Center Name Designation Mobile No Qualification* Experience 1 2 3 4 5 (*-Proof of qualification is required) 12 Sr. Contact Details Office No. (Head/ Regional / Branch / any other) 13 City and address Contact Person Telephone No. Fax No. E mail ID Jurisdiction List of the districts for which registration is required Page | 122 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 14 15 Components for which registration is required a) Open Vent Polyhouses Yes/No b) Climate controlled Polyhouses Yes/No c) Flat Top Net Houses Yes/No d) Round Top Net Houses Yes/No Information on R & D facilities available with the company. Provide details about a) Research Activities b) Development activities including 1. Farmer’s Training 2. Seminars 3. Visit of farmers If applicant manufacturers/supplier desire to conduct farmer’s training at Agri. polyclinics, the same may be indicated 16 List of dealers, district wise (use separate sheet if required) Sr. No. District Detail address with Phone No.& Fax Appointment CST/BST Jurisdiction year No. Whether dealer is Exclusive/ Non Exclusive 1 2 3 4 5 6 17 The details of farmer’s complaints received regarding manufacturing defects of components, action taken to redress them during the year 2012-13. Page | 123 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Certificate and Undertaking Certified that the above said information is true and correct and undersigned is aware that in case of any discrepancy/false information, the registration is liable to be cancelled and a suitable legal action will be taken against the company. Undersigned also agrees to execute guarantee and warranty of products and materialssupplied to the cultivators, as per mentioned inTerms & Conditions.as well as the Performance guarantee in the form of bank guarantee in the format(Annex-8)prescribed by the Commissionerate of Agriculture / Maharashtra State Horticulture and Medicinal Plant Board. The all Terms & Conditions are applicable & binding to me/us. Undersigned shall execute an agreement withCommissionerate of Agriculture/Maharashtra State Horticulture and Medicinal Plant Board within 15 days of registration for the year 2015-2016,failing which the registration will stand terminated without any notice. I/We also undertake to supply the materials as per specifications provided by MSHMPB/Department of agriculture keep the batch wise record of all the components/items of polyhouse/nethousealong with the details such as make, batch no./lot no. and mention in supply bill so that traceability of material supplied to any farmer will be possible. Place Date Signature of Competent Authority Name/Designation (with seal) Page | 124 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Annex-6 The make/brand name/s of different components of polyhouse/nethouse Sr.No. Name of the components Make/brand* (Note: * Manufacturer/supplier should enlist all the makes/brands of the components which they provide/use) Page | 125 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Annex-7 Price list of additional components (other than listed in Annex-2 if any) for poly house and net house Sr. No. Details of additional items Rate (Rs) Unit 1 2 3 4 5 6 7 8 9 10 Page | 126 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Annex-8 To, ________________________________ ________________________________ ________________________________ BANK GUARANTEE WHEREAS ______________________________________________,(hereinafter) called as CAO) have approved M/s ___________________________________________ (hereinafter called firm) for the supplies of Polyhouseand Nethouse (hereinafter called the said goods) under the Polyhouse and Nethouse Scheme(hereinafter called the said scheme) AND WHEREAS in pursuance and under the terms of the said approved of the firm, firm has agreed to furnish in favour of the CAO the Bank Guarantee for a sum of Rs.1,00,000.00 (Rupees one lakh only) for the due performance of his/her its obligation to the CAO under the terms and conditions of the G.R. of Govt. of Maharashtra performance as per the terms and conditions of G.R. and circular as when Govt. and Deptt. have issued. We, ________________________________________ (hereafter called the bank) hereby irrevocably and un-conditionally undertake and guarantee payment to CAO forthwith on demand being made by CAO in writing without dumur any and all monies anywise payable by firm, as may be specified in the notice of the demand made by the CAO to the bank upto an aggregate a sum of Rs. 1,00,000/- (Rupees one lakh only) and the bank hereby agree and undertake to the CAO that 1. The firm will have to give complete material to the farmers as mentioned in the bill invoice in quantity and quality as per specification. (with prescribed guarantee of materials), alongwith installation of Polyhouse and /or shadenet house work . 2. In consideration interalia of the firm paying to the guarantor the guarantee charges and executing requisites documents in favour of the bank and which have been done prior to the execution hereof and the request of the firm, the Bank hereby agree with CAO THAT in the event of any default and / or defaults being committed by the firm in payment to the firm of the said Rs. 1,00,000/- (Rupees one lakh only) and or any part thereof the Bank hereby irrevocably unconditionally and or without any demur and not withstanding any intimation and or direction by the firm to the contrary guarantee and convenients to pay to the CAO IN PUNE the said sum Rs. 1,00,000/- (Rupees one lakh only) and or any part thereof as the case may be. 3. The CAO shall be entitle to act under the terms hereof as if the Bank was the Principal Deptor to the CAO for payment of any amount upto the said sum of Rs. 1,00,000/- (Rupees one lakh only) guarantee by the Bank aforesaid to the CAO. 4. The guarantee is additional and without prejudice to any security of obligations which CAO may now of hereafter have from the firm and or any other person in respect of the said indebtness and or liabilities and or obligations hereby guaranteed and all rights and remedies in respect thereof are hereby reserved by the CAO in its favour. Page | 127 E:\2014-15\guideline\GUIDELINE 2014-15 PC. 5. The guarantee contained herein is irrevocable and unconditional shall be continuing guarantee and shall remain in force for a period of 36 months with effect from the date of guarantee. On the CAO serving on the bank notice of claim under this guarantee before the expiry of the said period, the same shall be enforeceable against the bank not withstanding the fact that the same is payable after expiry of the said period. 6. The guarantee shall be continuing guarantee and shall not be considered as wholly or partially satisfies or exhaust by any payments from time to time made by the Bank or the distributor or any settlements of the accounts between the CAO and the firm. 7. The bank shall make the payment to the firm at the time or from time to time a sum not exceeding in aggregate the said sum of Rs. 1,00,000/- (Rupees one lakh only) unconditionally and without any demur and irrespective of any instructions or directions given by the firm to the bank to without payment thereof or any ground whatsoever. The bank obligations of the bank in terms hereof shall not be anywise affected or suspended by reason of dispute (if any) having been raised by the firm (whether of not pending before any Arbitrator Office, Tribunal or Court) or any denial of liability by the firm stopping or preventing or purporating to stop or prevent any payment by the Bank of CAO in terms thereof. 8. The bank hereby further agrees with declares and undertake to CAO that his guarantee is and shall always be unconditional irrevocable and absolute till guaranteed amount hereunder have been paid in full to the CAO irrespective of any dispute of difference as to any liability of the firm under the said G.R. or invalidity, enforceability, illegality or otherwise of any terms, conditions or provision for the said G.R. between the firm and the CAO or otherwise. 9. This guarantee shall be determined of affected by the liquidation or winding up, dissolution of change of constitution or insolvency of the firm or change in the constitution of either the firm or bank but shall in respect and for all purposes be binding and operative until satisfactory performance of all the obligations by the firm towards CAO. 10. Notwithstanding anything contained herein : a) Our liability under this guarantee shall not exceed Rs. 1,00,000/- (Rupees one lakh only). b) The guarantee shall be valid up to ________________________. c) We are liable to pay the guaranteed amount or any part thereof under this guarantee only and only if you serve upon us a written claim of demand on or before _____________ (inclusive of claim period of three months). Place : Date : (Note: Bank Guarantee for a sum of Rs.50,000.00 (Rs. Fifty thousands only) for the manufacturers/suppliers registered in Maharashtra State as small scale unit) Page | 128 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Annex-9 Format of information board to be provided at each Service Center Specifications: Information board should be of size 5’ x 4’. The board should be preferably made from the iron/steel sheet with iron/steel angle of sufficient strength for mounting and fixed in foundation. Place: The board should be installed at each Service Station of Supplies/Manufacturer at the eye level for the height of normal person. Color: The background color should be blue and colors of letters should be white. Format Authorized Service Center of (Name of registered manufacturer/supplier) for Providing service for Polyhouse and Nethouses Contact Person: (Name of an agricultural engineer) Mobile: Landline: Fax: Email: Page | 129 E:\2014-15\guideline\GUIDELINE 2014-15 PC. Annex-10 Format of Registers to be maintained at each Service Center Register should be maintained at the Service Center and be made available to the concerned offices from Department of Agriculture/ Maharashtra State Horticulture and Medicinal Plant Board (MSHMPB)/State NHM, Maharashtra State and farmers/cultivators. There should be separate page for each farmers/cultivator to whom the polyhouse/nethouse has been supplied by the manufacturer/supplier in following format. Name of the farmer/cultivator: Address of farmers/cultivator: Landline Mobile: Email: The location where polyhouse/nethouse is provided: The details of polyhouse and nethouse provided 1. 2. 3. 4. 5. Size: Type: Total Price: Date of completion: Other items supplied: Page | 130 E:\2014-15\guideline\GUIDELINE 2014-15 PC.
© Copyright 2024