BUXBAUM ET AL when given to the mother in the first trimester of pregnancy remains to be determined. Anticoagulants were not effective or adequate to eliminate completely the risk of thromboembolism. However the patients who stopped the treatment during pregnancy carried a higher risk than those who continued and than those who never received anticoagulants. 1 Ueland K, Tatum HJ, Metcalfe J: Pregnancy and prosthetic heart valves. Report of successful pregnancies in two patients with Starr-Edwards aortic valves. Obstet Gynec 27 :257-260, 1966 2 Strickland NR, Mount J : Pregnancy after treatment of aortic stenosis and insufficiency with a Starr-Edwards valve. Obstet Gynec 27:508-510, 1966 3 Johnson AS, Meyers MP, Eckhous AS, et al: Successful pregnancies in patients with ~rosthetic mitral valves. Mich Med 65:718-719, 1966 4 Broustet P, Duhourg G , Mahon R: Grossesse et accouchement apri.s chirurgie cardiaque. C;ynec Obstet 66:522,1967 5 Starke H, Dann M, Kittle C F : Successful pregnancy following Starr-Edwards prosthetic aortic valve replacement. J Kansas Med Soc 68:252-253, 1967 6 McDonald TW, Dilworth EE: Successfi~lpregnancy in a patient with a Smeloff-Cutter mitral valve. J Louisiana Med Soc 119:497-498, 1967 7 Turner RWO, Kitchin AH: Pregnancy after mitral valve prosthesis. Lancet 1 :862-863, 1968 8 Carty AT, Crowdes RL: Pregnancy in ;1 patient with mitral valve prosthesis. Lancet 2:456-457, 1968 9 Hedstrand H, Cullhed I: Pregnancy in patients with prosthetic heart valves ( Starr-Edwards ) . Scand J Thorac Cardiovasc Surg 2: 196-199, 1968 10 Gordon G, O'Loughlin JA: Successful pregnancies in two patients with a Starr-Edwards heart valve prosthesis. J Obstet Gynec Brit Cwlth 76:73-76, 1969 11 Szekely P, Snaith L: Mitral valve prosthesis, warfarin anticoagulation and pregnancy. Lancet 2:598-599, 1969 12 Hart PG: Birth of a full-term healthy child fro111a mother with a Starr-Edwards prosthesis in the ~nitral orifice. Anticoagulant therapy during pregnancy and delivery. Nederl T Verlosk 69:401-409, 1969 13 Barnard PM, Heydenrych JJ, Lombard BG: hiitral valve prosthesis and pregnancy without anticoagulation therapy. S Afr Med J 43:1397-1398, 1969 14 Alieff A: Anticoagolantien in der schwangerschaft nach implantation kunstlicher herzklappen. Abl Gynack 91: 769-771, 1969 15 Zitnik RS, Brandenburg RO, Sheldon R, et al: Pregnancy and open-heart surgery. Circulation 39 (suppl I ) :257262, 1969 16 Hirsh J, Cade JF, O'Sullivan E F : Clinical experiences with anticoagulant therapy during pregnancy. Brit Med J 1:270-273, 1970 17 Bennett GG, Oakley CM: Pregnancy in a patient with a mitral valve prosthesis. Lancet 1 :616-619, 1968 18 Kreisler B, Mannor SM, Kariv I, et al: Pregnancy and labor following implanted ~nitralvalve prosthesis. Harefuah 78:227-228, 1970 19 Otterson WN. McGranahan G. Freeman MVR: Successful pregnancy with McGovern aortic prosthesis and longterm heparin therapy. Obstet Gynec 31:273-275, 1968 20 Palacois-Macedo X, Diaz-Devis C, Escudero J : Fetal risk with the use of coumarin anticoagulant agents in pregnant patients with intracardiac ball valve prosthesis. Amer J Cardiol24: 853-856, 1969 21 Kenmure ACF: Pregnancy in a patient with prosthetic mitral valve. J Obstet Gynec Brit Cwlth 75:581-582, 1968 22 Gilbert CS, Sullivan GJ, McLarlghlin JJ: Heart disease in pregnancy: ten year report from the Lewis Memorial Maternity Hospital. Obstet Gynec 9:58-63,1957 23 Quick AJ: Experimentally induced changes in prothrombin level of blood; prothrombin concentration of new-born pups of mother given Dicumarol before parturition. J Biol Chem 164:371-376, 1946 24 Kraus AP, Perlow S, Singer K: Danger of Dicumarol treatment in pregnancy. JAMA 139:758-762, 1949 25 Disaia PJ: Pregnancy and delivery of a patient with a Starr-Edwards mitral valve prosthesis. Obstet Gynec 28: 469-472, 1966 26 Kerber IF, Warr OS 111, Richardson C: Pregnancy in a patient with a prosthetic ~nitralvalve. JAMA 203:223225, 1968 27 Hultgreen H, Hubis H, Shumway N : Cardiac function following mitral valve replacement. Amer Heart J 75:302312,1968 28 McHenry hlM, Smeloff EA, Davey TB, et al: Hemodynamic results with full-flow orifice prosthetic valves. Circulation 35 (suppl I ) :24-33, 1967 29 Bristow JD, McCord CW, Stnrr A, et al: Clinical and hemodynamic results of aortic valvular replacement with a ball valve prosthesis. Circulation 29( suppl I ) :36-48, 1964 30 Ross J Jr, Morrow AG, Mason DT, et al: Left ventricular function following replacement of the aortic valve. Hemodynamic responses to muscular exercise. Circr~iation 33:507,1966 31 Harthorne JW, Rrtckley hlJ, (;ro\rer JW, et al: Valve replacenlent during pregnancy. Ann Intern hied 67: 10321034, 1967 32 Bloonifieltl DK, Ruhinstein 1,I: hlitral valve prosthesis, and pregnancy. Lancet 2:290warfarin anticoag~~lation, 291,1969 33 Laros RE, Hage l l L , Hayashi RH: Pregnancy and heart valve prosthesis. Ohstet Cynec 35:241-247, 1970 Reprint requests: Dr. Aygen. Beilinson Hospital, Petah Tiqva, Israel. Erratum In the article "Advantages of the Beall Valve Prosthesis" by Vogel e t a1 (Chest 59:249, 1871) figures 1 and 5 were reversed. CHEST, VOL. 59, NO. 6, JUNE 1971 Downloaded From: http://journal.publications.chestnet.org/ on 06/11/2014
© Copyright 2024