EDGE OUTLINE E V O L U T I O N LED Recessed Linear Perimeter Slot System Project Name Date Catalog Number Type CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Extruded alumi- num module with reflector and lens for perfect perimeter illumination. ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥91, 30K, 35K, and 40K is CRI≥83. MOUNTING Edge Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF for individual and continuous runs (runs designed to fall on-grid). Consult factory for detailed installation instructions. FINISH Standard powder-coat textured white painted finish on exposed trim. Driver cover to be painted standard white when custom color specified. Consult factory for custom colors. WARRANTY Edge Evolutuion LED offered with a 5-year limited warranty. Covers LED, driver and fixture. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. Standard (EVL) YEAR LED WARRANTY Shallow (EVLS) YEAR LED 4-1/2” WARRANTY 4-1/2” (114.3mm) (114.3mm) LFL LED Convertible LFL LED Convertible Convertible LED LFL L U M I N A I R E S P E C I F I C AT I O N Convertible EVL EVL_- ____- ___’- ___- HOUSING COLOR/LUMENS LENGTH MOUNTING ___- VOLTAGE 27K Color Temperature Lumen Options 2727K, 164 lumens/ft (4 watts/ft) 27HO- 27K, 313 lumens/ft (6 watts/ft) 27VHO- 27K, 404 lumens/ft (8 watts/ft) 30K Color Temperature Lumen Options 3030K, 200 lumens/ft (4 watts/ft) 30HO- 30K, 381 lumens/ft (6 watts/ft) 30VHO- 30K, 492 lumens/ft (8 watts/ft) 35K Color Temperature Lumen Options 3535K, 209 lumens/ft (4 watts/ft) 35HO- 35K, 398 lumens/ft (6 watts/ft) 35VHO- 35K, 514 lumens/ft (8 watts/ft) 40K Color Temperature Lumen Options 4040K, 214 lumens/ft (4 watts/ft) 40HO- 40K, 409 lumens/ft (6 watts/ft) 40VHO- 40K, 527 lumens/ft (8 watts/ft) RGB LED10 RGBX- RGB LED with DMX Controller Convertible 120- 120 V LED 277- 277 V 347- 347 V UNV- UNV (120-277) CIRCUITING __- ____ FINISH OPTIONS LED Convertible Circuit 1C- Single LFL 1D- Single Circuit Dimming5 1B- Single Circuit with Battery Pack5, 6,11 1E- Single Circuit with Emergency Circuit11 Acoustical Grid Ceiling G1- 1” (25.4mm) Ceiling Grid G9- 9/16” (14.3mm) Ceiling Grid GS- Screw Slot Ceiling Grid GB- 9/16” (14.3mm) Ceiling Grid with Bevel Trim Inaccessible Ceiling FL- Standard 1/2” (12.7mm Flange SF- Spackle Flange NF- Flangeless4 Individual Units2 2- 2’, 23” (584.2mm) fixture2 3- 3’, 35” (889mm) fixture2 4- 4’, 47” (1,193.8mm) fixture2 6- 6’, 71” (1,893.4mm) fixture2 8- 8’, 95” (2,413mm) fixture2 Sample Catalog #: EVL-30-24’-FL-120-1C-W EVLS __- YEAR LED WARRANTY 1 LFL EVL- Edge Evolution Outline EVLS- Edge Evolution Outline Shallow 4-1/4” (107.9mm) LFL 5-1/4” (133.4mm) LED QS- Quick Ship13 CP- Chicago Plenum GLR- Internal Fast blow fuse LGR- Low Glare Reflector12 C90I- 90˚ Inside Corner7,11 C90O- 90˚ Outside Corner7,11 C45I- 45˚ Inside Corner7,11 C45O- 45˚ Outside Corner7,11 EF- End Filler8 SW- Step Switching W- Matte White S- Metallic Silver (rails only)9 BL- Textured Black (rails only)9 BR- Bronze (rails only)9 CC- Custom Color (rails only)9 Continuous Runs3 xx’-Specify row length to 1’ (304.8mm) increments See back page for mounting detail. 2Individual units shipped with end plates uninstalled. 3Continuous runs made up of both even and odd length fixtures. Designed to fall on-grid. 4NF to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery packs with remote test switch are provided with 1B option. Available in 4’ or longer lengths. 7See back page for corner details. 8End Filler option used for fitting fixture into odd lengths. Filler is non-illuminated. Left and right end filler provided whe EF specified. 9Custom Color will be on fixture rails only. 10Osram/Sylvania Color Changing RGB LED and components are for accent or decorative lighting and does not provide room illumination. See back page for more information. 11Submittal drawings required. 12Low Glare Reflector (LGR) required on any layout with inside corner. LGR softens glare and changes polar cuvre and does effect lumen out put and efficacy, see back page for photometry. 13 Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago plenum, and GLR. 1 Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2015 Pinnacle Architectural Lighting® May 2015 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previous printed or electronic versions. PHOTOMETRICS EV_L 873 720 655 540 437 360 218 180 Test #: ITL84679 Part #: EVL-35HO-4 Lumens per watt: 66 Total Delivered Lumens: 1592 Test #: ITL84682 Part #: EVL-35HO-4-LGR Lumens per watt: 57 Total Delivered Lumens: 1376 EV3WG INDIVIDUAL AND CONTINUOUS RUN MODULES 1 1” Grid Mounting Options 23" (584.2mm) G1 G1 2' 9/16” Grid Mounting Options Screw Slot and 9/16” Mounting Flange Detail G9 FL G9 GS GS Non-Flange NF Spackle Flange SF (1) module per 2' unit 35" (889mm) 3' 71” (1893.4mm) or 72” (1828.8mm) Specify (1) module per 3' unit G1 in Mounting section of part #. 47” (1193.8mm) or 48” (1219.2mm) Specify G9 in Mounting section of part #. 6' Specify GS in Mounting section (2) modules per 6' unit of part #. Specify FL of part #. Specify NF of part #. 95” (2413mm) or 96” (2438.4mm) Specify SF of part #. 8' 4' (2) modules per 8' unit (1) module per 4' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. MOUNTING 1” Grid Mounting Options G1 G1 Specify G1 in Mounting section of part #. 9/16” Grid Mounting Options G9 G9 Specify G9 in Mounting section of part #. APPLICATION GUIDELINES Screw Slot and 9/16” Mounting GB GS Flange Detail GS Specify GS in Mounting section of part #. Non-Flange FL NF Specify FL of part #. Specify NF of part #. Spackle Flange SF Specify SF of part #. INSTALLATION Reflector Low Glare Reflector Outline easily installs into acoustical grid and inaccessible ceiling. Install wall rail onto wall and hook fixture onto rail. Tie off fixture to structure. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See installation instructions for detailed information. CORNERS 18”-20” Illumination 45° Inside 45° Inside 90° Inside End Filler 5° Outside 45° Outside 90° Outside 90° Outside Outline is designed to install flush against the wall. MUST BE INSTALLED PRIOR TO CEILING INSTALLATION. See installation instructions for detailed information. 90° Inside Pinnacle Lighting’s Outline is a complete perimeter lighting solution. The inside, outside corners, and end fillers allow designers to Outline a space. The 45 degree and 90 degree corners allow for +/- 5 degrees of adjustability to accommodate any wall imperfections. Specify runs to the nearest foot and non-illuminated corners are slid into place to finish the perimeter lighting. Minimum distance for corners is 5-1/2” from the wall, with a max of 12” away from the wall. The End Fillers have a maximum of 6” per end. See installation instructions for detailed information. End Filler Inside Corner Outside Corner Detail Detail Detail Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2015 Pinnacle Architectural Lighting® May 2015 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
© Copyright 2024