High Performance Photodiode Sensors 918D SERIES Post, post holder, and clamping fork available for purchase separately The RoHs compliant 918D Series Photodiode Sensors are calibrated photodiode sensors with advanced features to enhance performance. UV and Visible Detectors, 200 - 1100 nm 918D-SL-OD1R Silicon Detector, 400-1100 nm, OD1 Attenuator, DB15 Connector 918D-SL-OD2R Silicon Detector, 400-1100 nm, OD2 Attenuator, DB15 918D-SL-OD3R Silicon Detector, 400-1100 nm, OD3 Attenuator, DB15 918D-UV-OD3R UV Silicon Detector, 200-1100 nm, OD3 Attenuator, DB15z • Smallest calibration uncertainty specifications in market • Internal temperature sensor for thermal drift compensation • Integrated attenuator, selectable from 10X to 1000X • Attenuator on/off sensor • Free-space and fiber optic measurements • RoHS compliant Germanium Detectors, 780 - 1800 nm 918D-IR-OD1R Germanium Detector, 780-1800 nm, OD1 Attenuator, DB15 918D-IR-OD2R Germanium Detector, 780-1800 nm, OD2 Attenuator, DB15 Features 918D-IR-OD3R Germanium Detector, 780-1800 nm, OD3 Attenuator, DB15 Tightest Calibration Uncertainty InGaAs Detectors, 800 - 1650 nm 918D-IG-OD1R InGaAs Detector, 800-1650 nm, OD1 Attenuator, DB15 918D-IG-OD2R InGaAs Detector, 800-1650 nm, OD2 Attenuator, DB15 918D-IG-OD3R InGaAs Detector, 800-1650 nm, OD3 Attenuator, DB15 Enhanced Features The Attenuator on/off switch can be automatically recognized by power meter models 1830-R, 1918-R, 1936-R, and 2936-R. The 918D Series include a full spectral response calibration utilizing NIST-traceable standards calibrated with highprecision equipment maintained in Newport’s optical detector calibration facility. Tight calibration facility and process control allows the tightest calibration uncertainty in industry. Each detector is shipped with the calibration data, which is electronically stored inside the detector's EEPROM. A certificate of calibration as well as the actual calibration curves and data are shipped with each detector for attenuator and no attenuator modes. To maintain accuracy and guarantee performance Newport recommends annual photodiode detector calibration. S E R I E S The 918D Series Photodiode Sensors are designed to outperform Newport's industry proven 818 Series Calibrated Photodiode Sensors , by enhancing their performance with advanced features. They feature integrated calibration data storage, built-in OD1, OD2 or OD3 attenuation filter with an electronic attenuator On/Off sensor, and sensing electronics for temperature drift compensation, making the detector more accurate in temperature changes. Exclusive OD3 attenuator technology extends the calibrated optical dynamic range of our detectors by three decades. Our attenuator design provides high damage threshold and spectral flatness. With the low NEP associated with the photodiodes Newport is using, a wider dynamic range is achieved. For less than 1 mW input power, we recommend to put the attenuator to OFF position (0.1 mW for 918D-UVOD3R between 200 - 400 nm) to maximize the signal to noise ratio. Highest Quality Photodiodes Plots of various photodiode characteristics Wide Dynamic Range with Built-in Attenuator 10 ABSOLUTE SPECTRAL RESPONSIVITY (A/W) 9 1 8 D 10 0 -1 Without OD3 Attenuator 10 10 10 -2 -3 -4 With OD3 Attenuator 10 -5 200 400 600 800 1000 1200 WAVELENGTH (nm) 1400 1600 818-UV/818-ST2-UV 918D-UV/918D-ST-UV 818-IR/918D-IR 818-ST2-IR/918D-ST-IR 818-IS-1/918D-IS-1 818-SL/918D-SL 818-ST2/918D-ST 818-IG/918D-IG Typical spectral responsivity of Newport's low power detectors 1800 Newport uses the highest quality semiconductor detector materials available. Available sensor types are silicon (Si), UV-enhanced Si, Germanium, and Indium Gallium Arsenide (InGaAs). Choose 918D-UV-OD3R for 200 - 400 nm wavelength, but note that the maximum measurable power level in 400 - 1100 nm is as low as 50 mW with the attenuator on. Newport’s advanced in-house calibration facility performs the tightest calibrations in the business, further improving the absolute accuracy of our detectors. Dimensions 1.32 (33.5) 0.60 (15.2) Detector Surface 0.228 (5.8) 8-32 THD 0.25 DP Accessories To directly mount the 918D head to an optical table consider the 918D-BASE-KITR. It has an optical axis height of 1.00" and is compatible with both Imperial and Metric table tops. #8 DA15P Connector M4 Free Space and Fiber Optic Adapters Ø1.75 (Ø44.5) Ø0.406 (Ø10.3) 1.000-4OUNS-2B THR 9 1 8 D S E R I E S 918D Series Detector Specifications Model 918D-UV-OD3R 918D-SL-OD3R 918D-IR-OD3R 918D-IG-OD3R Spectral Range (nm) 200 to 1100 400 to 1100 780 to 1800 800 to 1650 Max. Measurable Power w/ Attenuator (W) 0.2W (200 - 400 nm) and 50 mW (400 - 1100 nm) 2 2 2 Max. Measurable Power w/o Attenuator (mW) 0.3 mW (200 - 400 nm); 0.1 mW (400 - 600 nm, >1050 nm), 0.07 mW (600 - 1050 nm) 4 mW 10 mW 10 mW Power Density, Average Maximum w/o Attenuator (W/cm2)(1) 0.2 2 3 3 Pulse Energy, Maximum - w/ Attenuator (J)(2) 500 n 5m 5m 5m Pulse Energy, Maximum - w/o Attenuator (J) 0.5 n 5n 5n 5n Calibration Uncertainty (Without Attenuator)(5) 4% @ 200-219nm, 2% @ 220-349nm, 1% @ 350-949nm, 4% @ 950-1100nm 1% @ 400-940nm, 4% @ 941-1100nm 2% @ 780-910nm, 2% @ 911-1700nm, 4% @1701-1800nm 2% @ 800-900nm, 2% @ 901-1650nm Calibration Uncertainty (With Attenuator)(5) 8% @ 200-219nm, 2% @ 220-349nm, 1% @ 350-949nm, 4% @ 950-1100nm 1% @ 400-940nm, 4% @ 941-1100nm 5% @ 780-910nm, 2% @ 911-1700nm, 4% @ 1701-1800nm 5% @ 800-900nm, 2% @ 901-1650nm Power Density, Average Max w/ Attenuator (W/cm2)(1) 30 Uniformity (%)(3) ±2 Linearity (%) ±0.5 Rise Time (ms) 5.9 2 2 2 Material UV Enhanced Silicon Silicon Germanium Indium Gallium Arsenide Active Area (cm2) 1 Active Diameter (cm) 1.13 0.071 0.3 Shape Attenuator Built-In OD3 Built-In (4) Calibration Stored Internally Operating Temperature 5°C to 50°C, <70% RH Built-In (4) Built-In (4) Based on maximum power density of the OD3 attenuator. For OD2 reduce the value by 10x, & for OD1, derate value by 100x. 15 ns pulse width, max w/ attenuator is for OD3. For OD2 derate listed value by 10x, & for OD1, derate value by 100x. Uniformity specification applies to photodiode only. It does not apply to the attenuator. Selected at time of ordering. Calibration uncertainty can be varied depending on the NIST transfer standard uncertainty variation. Newport Corporation, Global Headquarters 1791 Deere Avenue, Irvine, CA 92606, USA PHONE: 1-800-222-6440 1-949-863-3144 FAX: 1-949-253-1680 www.newport.com EMAIL: [email protected] Complete listings for all global office locations are available online at www.newport.com/contact Newport Corporation, Irvine, California and Franklin, Massachusetts; Evry and Beaune-la-Rolande, France and Wuxi, China have all been certified compliant with ISO 9001 by the British Standards Institution. Santa Clara, California is DNV certified. DS- 041503 1) 2) 3) 4) 5) Cylinder
© Copyright 2024