www.osram-americas.com PrevaLED® Core Pro AC LED Light Engine for Spot and Downlighting Key Features & Benefits —— High efficacy LED module with integrated driver offering up to 103 LPW —— Cost reduction by omitting gearbox, cable, cover glass, and simplified assembly —— Phase-cut dimmable down to 10% —— Poke-in wire connectors for easy installation —— Integrated driver allows direct connection to 120Vac —— Available in both >80 and >90 CRI —— Industry standard mounting hole pattern allows for compatibility with existing accessories in the market and eliminates the need for additional driver electronic control gear PrevaLED Core Pro AC LED light engines are highly efficient, 120Vac integrated modules ideal for use in recessed downlights, accent and track lighting. These modules are phase-cut dimmable down to 10% and are available in multiple color temperatures in both 2000 and 3000 lumen packages. The form factor of the PrevaLED AC Core is similar to Zhaga Book 3 making it easy to integrate into typical luminaire form factors. In addition, the PrevaLED Core Pro AC offers a comprehensive five year warranty. —— Superior dimming performance with no strobing and flickering —— Long Life: up to 50,000 hours (L70) minimizing maintenance frequency —— 5 year warranty —— Automatic thermal roll-back in case of over temperature (>100°C) increases the reliability of the product and application Product Offering Item Nominal Lumens PrevaLED Core Pro AC 2000 PrevaLED Core Pro AC 3000 CRI Color Temperature 90 2700K & 3000K 80 3500K & 4000K 903000K 80 3500K & 4000K Application Information Applications Specifications and Certifications —— Accent lighting —— Area lighting —— Recessed downlights —— Track lighting T he OSRAM PrevaLED Core Pro AC is UL8750 Recognized for the US and Canada UL File E320662, Vol. 1 F CC Part 15 Class A LED457R1 6-15 Specification Data Catalog # Type Project Comments Prepared by Ordering Information Item Number Ordering Abbreviation 74108 PL-CORE-PRO AC-PC-2000-927-120V 73400PL-CORE-PRO-AC-PC-2000-930-120V 73401PL-CORE-PRO-AC-PC-2000-835-120V 73402PL-CORE-PRO-AC-PC-2000-840-120V 73403PL-CORE-PRO-AC-PC-3000-930-120V 73404PL-CORE-PRO-AC-PC-3000-835-120V 73405PL-CORE-PRO-AC-PC-3000-840-120V Input Initial Voltage Lumens (lm) 120Vac1750 120Vac1820 120Vac2000 120Vac2080 120Vac2600 120Vac2890 120Vac2960 Light Emitting Surface (LES) 19 19 19 19 19 19 19 Beam Angle 120 120 120 120 120 120 120 Color Nominal Temperature CRI Wattage (W) 2700K >9020 3000K >9021 3500K >8020 4000K >8020 3000K >9033 3500K >8031.5 4000K >8031.5 Note: 1. All data shown above are taken at Tc=65°C and input of 120Vac, 60Hz 2. L 70 B 50 of 50,000 hrs at Tc= 65°C 3. Color consistency of <4 SDCM 4. Minimum dimming is dependent on the dimmer used. A dimming of at least 10% is achieved using the compatibility list in the section on following page Dimming4 <10% <10% <10% <10% <10% <10% <10% LPW 87 87 100 103 79 92 94 Case Qty. 20 20 20 20 20 20 20 Ordering Guide PL - CORE -AC - PC - 2000 - 9 LED Module Family Family category AC Input Phase-Cut Lumen Output CRI ® PL = PrevaLED Dimmable 9 = >90 8 = >80 Minimum and Maximum Ratings ParameterValues Maximum temperature at TC 90°C (194°F) Modulation at 120Hz <40% Operating voltage 108Vac - 132Vac Ambient operating temperature -20°C to 50°C Storage temperature -20°C to 65°C Note: If at any point during operation, the Tc exceeds 90°C the thermal derating feature is activated and the power will roll back to less than 5% of the input power 0.58 (14.8) Assembly Diagram 3.14 (80) 3.14 (80) 0.12 (3.3) 2 PLACES 0.58 (14.8) 3.14 (80) 0.12 (3.3) 2 PLACES 1.37 (35) 3.14 (80) Dimensions: in.(mm) Wiring Diagram Phase-cut Dimmer 1.37 (35) Line Neutral 27 - 120V Color Temperature Input Current 27 = 2700K 120Vac 30 = 3000K 35 = 3500K 40 = 4000K Dimmer Compatibility BrandModel LEVITON Sureslide 6615-P0W LEVITON Decora Sureslide 6674-P0T LEVITON Vizia+ VPM10-1LZ LEVITON IllumaTech IPI06-1LZ LUTRON D-600P LUTRON DV-600P LUTRON S-600P LUTRON SCL-153P LUTRON MACL-153M LUTRON DVELV-303P Assembly Information 1. Carefully attach the module to heat sink sandwiching appropriate thermal interface material (TIM) to adequately dissipate thermal power. 2. Refer to Application Guide (LED460) for detailed assembly information. Safety Information WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION. TO AVOID ELECTRICAL SHOCK OR COMPONENT DAMAGE, DISCONNECT POWER BEFORE ATTEMPTING INSTALLATION OF THE POWER SUPPLIES AND/OR MODULES. Failure to install the power supplies and/or LED modules in accordance with the National Electric Code (NEC), all applicable Federal, State and local electric codes as well as the specific Underwriter’s Laboratories (UL) safety standards for the installation, location and application may cause serious personal injury, death, property damage and/or product malfunction. 1. For safety reasons the LED light engine must not be operated if the housing is damaged. 2. The LED engine needs to be built into a luminaire. 3. Suitable only for operation with 120Vac input voltage. 4. Conducting paths on the circuit board must not be damaged or destroyed during installation. 5. The LED module itself and all its components may not be mechanically stressed. 6. It is highly recommended to use a thermal interface material (TIM). The TIM needs to enable adequate heat transfer, during installation it has to be taken care not to create air inclusions between surfaces. For this purpose, it is recommended to use a heat sink with even and clean surfaces. 7. T he LED module should be mounted to a heat sink with M3 screws or suitable accessories. Maximum tightening torque for mounting screws need to be observed as excessive force may damage the housing. 8. Protect against splashes! 9. D amage by corrosion will not be honored as materials defect claim. PrevaLED Core is recommended for indoor use only (IP 20). It is the user's responsibility to provide suitable protection against corrosive agents, such as moisture, condensation and other harmful elements. 10. T o avoid mechanical damage, the LED modules have to be attached securely to the intended mounting surface. It is recommended to avoid heavy vibration. 11. D o not remove the cover or the safety glass from the LED module. Do not operate an LED module when the safety glass is broken, missing or cracked. 12. Installation of LED module needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installation. 13. Pay attention not to exceed the maximum operation temperature of 90°C at the Tc point when the modules are used in an enclosed environment. 14. The design of the housing/luminaire should be according to the IP standards applicable for the intended application. 15. For maximum safe operation per UL, refer to Conditions of Acceptability (CoA). 16. Maximum operating temperature for warranty coverage is 90°C. Americas Headquarters OSRAM SYLVANIA Inc. 100 Endicott Street Danvers, MA 01923 USA Phone 1-800-LIGHTBULB (1-800-544-4828) www.osram-americas.com OSRAM, PrevaLED, LED CREATING TOMORROW and OPTOTRONIC are registered trademarks of OSRAM GmbH. Specifications subject to change without notice. © 2015 OSRAM
© Copyright 2024