Completing CDS Worksheets DP Flow 1

Completing CDS Worksheets
DP Flow
1
What is a CDS?
z
CDS – Configuration Data Sheet
A Configuration Data Sheet is a form used to gather the
necessary application/instrumentation information in order to
properly configure the specified device.
z
NOTE:
Configuration Data Sheets are NOT required. However, all of
the information contained within the CDS IS required for proper
configuration.
Emerson Confidential
2
The DP Flow CDS Structure
z
The DP Flow CDS has been broken into 3 sections:
– DP Flow Section (pprimaryy element and pprocess information)
– Transmitter Section (transmitter or flowmeter information)
– Custom Fluid Section (custom gas, custom liquid, or natural gas information)
z
Only necessary CDS forms need to be completed
DP Flow CDS
Information is required
q
for all DP Flow orders
Transmitter CDS
Information is only required if needed –
C1 option, C2 option, Flowmeters
Custom Fluid CDS
Information is only required if needed –
if process includes a custom fluid
Emerson Confidential
3
The DP Flow CDS Structure
DP Flow
CDS
DP Flow
Transmitter /
Flowmeter
CDS
3051SMV
3051S
3051C
2051C
3095
Custom Fluid
CDS
Emerson Confidential
Custom Gas
Custom Liquid
Natural Gas
The DP Flow CDS Structure –
DP Flow CDS
DP Flow
CDS
DP Flow
Emerson Confidential
z
Start with the DP Flow CDS. All DP Flow orders must
be accompanied with this CDS
z
The DP Flow CDS includes:
z
Primary element information
z
Information about the process / application
The DP Flow CDS Structure –
Transmitter / Flowmeter CDS
z
A Transmitter / Flowmeter CDS is only required if:
z
A transmitter is ordered with a C1 or C2 option
z
A flowmeter is ordered. Models include:
3051SFx, 3051CFx, 2051CFx, 3095MFx
Transmitter /
Flowmeter
CDS
3051SMV
z
Emerson Confidential
3051S
3051C
2051C
3095
The Transmitter / Flowmeter CDS includes:
z
Information about the desired configuration for the
transmitter / flowmeter
The DP Flow CDS Structure –
Custom Fluid CDS
z
A Custom Fluid CDS is only required if:
z
The process contains a gas or a liquid that is not
included in the database gas / database liquid list
z
Th process iis a N
The
Natural
t l Gas
G application
li ti
Custom Fluid
CDS
Emerson Confidential
Custom Gas
Custom Liquid
Natural Gas
DP Flow CDS Examples
z
The following pages contain examples of the
proper CDS worksheets to fill out for different DP
Flow applications
Emerson Confidential
8
DP Flow CDS Examples
z
Conditioning Orifice Plate in a water application
–
Only
y a DP Flow CDS is needed
Emerson Confidential
9
DP Flow CDS Examples
z
3051 Transmitter with Annubar primary element in an air
pp
application
–
DP Flow CDS and 3051 CDS are needed
Emerson Confidential
10
DP Flow CDS Examples
z
3051SMV Flowmeter with a Compact Conditioning Orifice
primary
y element in a Natural Gas application
pp
Plate p
–
DP Flow, 3051SMV, and Natural Gas CDS are needed
Emerson Confidential
11
Webpage Helps Guide You Through the Process
Emerson Confidential
12
List of DP Flow CDS Document Numbers
CDS Title
Document Number
DP Flow CDS
00806-0100-4010
3051SMV CDS
00806-0100-4803
3051S CDS
00806-0100-4801
3051C CDS
00806-0100-4001
2051C CDS
00806-0100-4101
3095M CDS
00806-0100-4716
Custom Gas CDS
00806-0200-4716
Custom Liquid
q
CDS
00806-0300-4716
Natural Gas CDS
00806-0300-4803
Emerson Confidential
13