Completing CDS Worksheets DP Flow 1 What is a CDS? z CDS – Configuration Data Sheet A Configuration Data Sheet is a form used to gather the necessary application/instrumentation information in order to properly configure the specified device. z NOTE: Configuration Data Sheets are NOT required. However, all of the information contained within the CDS IS required for proper configuration. Emerson Confidential 2 The DP Flow CDS Structure z The DP Flow CDS has been broken into 3 sections: – DP Flow Section (pprimaryy element and pprocess information) – Transmitter Section (transmitter or flowmeter information) – Custom Fluid Section (custom gas, custom liquid, or natural gas information) z Only necessary CDS forms need to be completed DP Flow CDS Information is required q for all DP Flow orders Transmitter CDS Information is only required if needed – C1 option, C2 option, Flowmeters Custom Fluid CDS Information is only required if needed – if process includes a custom fluid Emerson Confidential 3 The DP Flow CDS Structure DP Flow CDS DP Flow Transmitter / Flowmeter CDS 3051SMV 3051S 3051C 2051C 3095 Custom Fluid CDS Emerson Confidential Custom Gas Custom Liquid Natural Gas The DP Flow CDS Structure – DP Flow CDS DP Flow CDS DP Flow Emerson Confidential z Start with the DP Flow CDS. All DP Flow orders must be accompanied with this CDS z The DP Flow CDS includes: z Primary element information z Information about the process / application The DP Flow CDS Structure – Transmitter / Flowmeter CDS z A Transmitter / Flowmeter CDS is only required if: z A transmitter is ordered with a C1 or C2 option z A flowmeter is ordered. Models include: 3051SFx, 3051CFx, 2051CFx, 3095MFx Transmitter / Flowmeter CDS 3051SMV z Emerson Confidential 3051S 3051C 2051C 3095 The Transmitter / Flowmeter CDS includes: z Information about the desired configuration for the transmitter / flowmeter The DP Flow CDS Structure – Custom Fluid CDS z A Custom Fluid CDS is only required if: z The process contains a gas or a liquid that is not included in the database gas / database liquid list z Th process iis a N The Natural t l Gas G application li ti Custom Fluid CDS Emerson Confidential Custom Gas Custom Liquid Natural Gas DP Flow CDS Examples z The following pages contain examples of the proper CDS worksheets to fill out for different DP Flow applications Emerson Confidential 8 DP Flow CDS Examples z Conditioning Orifice Plate in a water application – Only y a DP Flow CDS is needed Emerson Confidential 9 DP Flow CDS Examples z 3051 Transmitter with Annubar primary element in an air pp application – DP Flow CDS and 3051 CDS are needed Emerson Confidential 10 DP Flow CDS Examples z 3051SMV Flowmeter with a Compact Conditioning Orifice primary y element in a Natural Gas application pp Plate p – DP Flow, 3051SMV, and Natural Gas CDS are needed Emerson Confidential 11 Webpage Helps Guide You Through the Process Emerson Confidential 12 List of DP Flow CDS Document Numbers CDS Title Document Number DP Flow CDS 00806-0100-4010 3051SMV CDS 00806-0100-4803 3051S CDS 00806-0100-4801 3051C CDS 00806-0100-4001 2051C CDS 00806-0100-4101 3095M CDS 00806-0100-4716 Custom Gas CDS 00806-0200-4716 Custom Liquid q CDS 00806-0300-4716 Natural Gas CDS 00806-0300-4803 Emerson Confidential 13
© Copyright 2024