How to read data out of the swingo 750/1250 E & B models The software is needed to read out data or to change/adjust certain parameters (runs on electronics from V2.0 or higher, default Values on CD are according V2.4) Requirements: - TASKI swingo (series models) - Laptop - Adapter cable set 17606-39: Software, Cable Step by step - Switch off machine / unplug the mains driven machines Remove dashboard without disconnecting flat band cables Switch on computer Connect PC with machine (socket J6, see picture below) Put the board back in its original position, without fixation Switch on the machine / plug in the mains driven machines Start Software Double click on „Parameter list“ (as you have not the password, you are able to change only some parameters) Change/adjust parameters according to parameter list (a red cross in the title shows: no access for any parameters in the file, these parameters are marked grey) when all necessary changes/adjustments are done, store the data on the board with icon „Programming Board“ Log off the program with „Close“ Switch off machine / unplug the mains driven machines Disconnect Machine and computer Remount dashboard Test all functions of the machine Minor malfunctions Make sure, that port com 1 is not occupied by other software applications, e.g. palm, modem etc. otherwise there won’t be a data exchange! Overview board Processor with Software Version Socket J6 for reading out data Socket for additional mechanical hour counter Program description Parameters with access black Loads an existing file, e.g. from default data on this CD Saves data onto your Laptop No access without password light grey Saves data onto the board of the machine Close Programm Parameterlist swingo (all models) Unit Drive control Brush unit Parameter Description Machine type Min Max 1 2 3 4 5 6 7 8 Current limitation Time acceleration ramp forward Time braking ramp forward Time acceleration ramp backward Time braking ramp backward Current limitation Delay current limitation Delay brush lowering manually to brush coupling Delay brush lowering with motor to brush coupling Time brush coupling Brush lowering with motor / 0 = without / 1 = with Delay brush stop Battery type / maintenance free = 0 / wet = 1 Battery charger / int. charger = 0 / ext. charger = 1 Battery charging time Battery charging cycles Running hours electronics Running hours vac motor Running hours brush motor Running hours brush positioning motor (Linac) Running hours drive motor Running hours dosing pump Switching cycles electronics Switching cycles vac motor Switching cycles brush motor Switching cycles brush positioning motor (Linak) Switching cycles drive motor Switching cycles dosing pump Service interval Service hours counter (Service LED) B2 B2 B2 B2 B2 B1/B2 B1/B2 B1/B2 10 0.4 0.4 0.4 0.4 15 0.2 0.1 B2 9 10 11 Battery type Hours counter 47 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Service interval 26 27 28 29 Step size To be programmed 27 3 3 3 3 38 8 2 Default V2.4 24 2.9 1.8 2.9 1.8 38 3 0.3 1 0.1 0.1 0.1 0.1 1 0.1 0.1 No No No No No No No No 0.1 2 0.5 0.1 No B1/B2 B2 0 0 3 1 1.5 0 0.1 1 No Yes B1/B2 B1/B2 B1/B2 0 0 0 1 1 1 0.6 0 0 0.1 1 1 No Yes Yes B1/B2 B1/B2 E/B1/B2 B1/B2 B1/B2 B2 0 0 0 0 0 0 27'962 27'962 27'962 27'962 27'962 27'962 0 0 0 0 0 0 0.1 1 0.1 0.1 0.1 0.1 No No No No No No B2 B1/B2 B1/B2 B1/B2 B1/B2 B2 0 0 0 0 0 0 27'962 27'962 27'962 27'962 27'962 27'962 0 0 0 0 0 0 0.1 0.1 1 1 1 1 No No No No No No B2 B1/B2 E/B1/B2 E/B1/B2 0 0 200 0 27'962 27'962 900 27'962 0 0 450 0 1 1 1 0.1 No No Yes Yes Unit Battery monitoring Parameter 30 32 33 34 35 36 37 38 39 40 41 42 Battery reset level fully charged (maintenance free) Battery reset level partially charged (maintenance free) Battery 3 LEDs (maintenance free) Battery 2 LEDs (maintenance free) Battery 1 LED (maintenance free) Battery warn level (maintenance free) Battery reset level fully charged (wet) Battery reset level partially charged (wet) Battery 3 LEDs (wet) Battery 2 LEDs (wet) Battery 1 LED (wet) Battery warn level (wet) Supply Voltage 230V = 1 / 110V = 0 43 44 45 46 Threshold value undervoltage110V Switch off delay undervoltage 110V Threshold value undervoltage 230V Switch off delay undervoltage 230V 31 Voltage monitoring Description B1 = small battery machines without traction motor, 750 B eco B2 = large battery machines 750/1250B Power E = mains driven machines 750/1250E Machine type Min Max Step size To be programmed 28 Default V2.4 25.6 B1/B2 20 0.05 No B1/B2 20 28 24.6 0.05 No B1/B2 B1/B2 B1/B2 B1/B2 B1/B2 B1/B2 B1/B2 B1/B2 B1/B2 B1/B2 E 20 20 20 20 20 20 20 20 20 20 0 28 28 28 28 28 28 28 28 28 28 1 23.8 22.8 21.8 21 25.6 24.6 23.8 22.8 21.8 21 1 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05 1 E E E E 60 0.2 160 0.2 100 1.2 200 1.2 80 0.8 180 0.5 1 0.1 1 0.1 No No No No No No No No No No Boards with diff. Volt. are avail. seperately No No No No
© Copyright 2024