How to read data out of the swingo 750/1250 E... The software is needed to read out data or to... (runs on electronics from V2.0 or higher, default Values on...

How to read data out of the swingo 750/1250 E & B models
The software is needed to read out data or to change/adjust certain parameters
(runs on electronics from V2.0 or higher, default Values on CD are according V2.4)
Requirements:
- TASKI swingo (series models)
- Laptop
- Adapter cable set 17606-39: Software, Cable
Step by step
-
Switch off machine / unplug the mains driven machines
Remove dashboard without disconnecting flat band cables
Switch on computer
Connect PC with machine (socket J6, see picture below)
Put the board back in its original position, without fixation
Switch on the machine / plug in the mains driven machines
Start Software
Double click on „Parameter list“ (as you have not the password, you are able to change only some
parameters)
Change/adjust parameters according to parameter list (a red cross in the title shows: no access for
any parameters in the file, these parameters are marked grey)
when all necessary changes/adjustments are done, store the data on the board with icon
„Programming Board“
Log off the program with „Close“
Switch off machine / unplug the mains driven machines
Disconnect Machine and computer
Remount dashboard
Test all functions of the machine
Minor malfunctions
Make sure, that port com 1 is not occupied by other software applications, e.g. palm, modem etc.
otherwise there won’t be a data exchange!
Overview board
Processor with Software Version
Socket J6 for reading out data
Socket for additional mechanical
hour counter
Program description
Parameters with access
black
Loads an existing file, e.g.
from default data on this CD
Saves data onto
your Laptop
No access without password
light grey
Saves data onto the board
of the machine
Close
Programm
Parameterlist swingo (all models)
Unit
Drive control
Brush unit
Parameter
Description
Machine type
Min
Max
1
2
3
4
5
6
7
8
Current limitation
Time acceleration ramp forward
Time braking ramp forward
Time acceleration ramp backward
Time braking ramp backward
Current limitation
Delay current limitation
Delay brush lowering manually to brush
coupling
Delay brush lowering with motor to brush
coupling
Time brush coupling
Brush lowering with motor / 0 = without / 1 =
with
Delay brush stop
Battery type / maintenance free = 0 / wet = 1
Battery charger / int. charger = 0 / ext.
charger = 1
Battery charging time
Battery charging cycles
Running hours electronics
Running hours vac motor
Running hours brush motor
Running hours brush positioning motor
(Linac)
Running hours drive motor
Running hours dosing pump
Switching cycles electronics
Switching cycles vac motor
Switching cycles brush motor
Switching cycles brush positioning motor
(Linak)
Switching cycles drive motor
Switching cycles dosing pump
Service interval
Service hours counter (Service LED)
B2
B2
B2
B2
B2
B1/B2
B1/B2
B1/B2
10
0.4
0.4
0.4
0.4
15
0.2
0.1
B2
9
10
11
Battery type
Hours counter
47
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Service interval
26
27
28
29
Step size
To be programmed
27
3
3
3
3
38
8
2
Default
V2.4
24
2.9
1.8
2.9
1.8
38
3
0.3
1
0.1
0.1
0.1
0.1
1
0.1
0.1
No
No
No
No
No
No
No
No
0.1
2
0.5
0.1
No
B1/B2
B2
0
0
3
1
1.5
0
0.1
1
No
Yes
B1/B2
B1/B2
B1/B2
0
0
0
1
1
1
0.6
0
0
0.1
1
1
No
Yes
Yes
B1/B2
B1/B2
E/B1/B2
B1/B2
B1/B2
B2
0
0
0
0
0
0
27'962
27'962
27'962
27'962
27'962
27'962
0
0
0
0
0
0
0.1
1
0.1
0.1
0.1
0.1
No
No
No
No
No
No
B2
B1/B2
B1/B2
B1/B2
B1/B2
B2
0
0
0
0
0
0
27'962
27'962
27'962
27'962
27'962
27'962
0
0
0
0
0
0
0.1
0.1
1
1
1
1
No
No
No
No
No
No
B2
B1/B2
E/B1/B2
E/B1/B2
0
0
200
0
27'962
27'962
900
27'962
0
0
450
0
1
1
1
0.1
No
No
Yes
Yes
Unit
Battery
monitoring
Parameter
30
32
33
34
35
36
37
38
39
40
41
42
Battery reset level fully charged
(maintenance free)
Battery reset level partially charged
(maintenance free)
Battery 3 LEDs (maintenance free)
Battery 2 LEDs (maintenance free)
Battery 1 LED (maintenance free)
Battery warn level (maintenance free)
Battery reset level fully charged (wet)
Battery reset level partially charged (wet)
Battery 3 LEDs (wet)
Battery 2 LEDs (wet)
Battery 1 LED (wet)
Battery warn level (wet)
Supply Voltage 230V = 1 / 110V = 0
43
44
45
46
Threshold value undervoltage110V
Switch off delay undervoltage 110V
Threshold value undervoltage 230V
Switch off delay undervoltage 230V
31
Voltage
monitoring
Description
B1 = small battery machines without traction motor, 750 B eco
B2 = large battery machines 750/1250B Power
E = mains driven machines 750/1250E
Machine type
Min
Max
Step size
To be programmed
28
Default
V2.4
25.6
B1/B2
20
0.05
No
B1/B2
20
28
24.6
0.05
No
B1/B2
B1/B2
B1/B2
B1/B2
B1/B2
B1/B2
B1/B2
B1/B2
B1/B2
B1/B2
E
20
20
20
20
20
20
20
20
20
20
0
28
28
28
28
28
28
28
28
28
28
1
23.8
22.8
21.8
21
25.6
24.6
23.8
22.8
21.8
21
1
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
1
E
E
E
E
60
0.2
160
0.2
100
1.2
200
1.2
80
0.8
180
0.5
1
0.1
1
0.1
No
No
No
No
No
No
No
No
No
No
Boards with diff. Volt.
are avail. seperately
No
No
No
No