Options Lamp Selection Chart Description Add Suffix PulsePlus Diagnostics (Not available with Nickel Cadmium). ...PPD Non-standard input voltage ....................................contact factory 277 Volt AC (AC and AC/DC Exit Only) ................................277 277 Volt Dual Circuit ....................................................277-2 120 Volt Dual Circuit............................;„.......,.,...„...... 120-2 Flasher (DC Lamps Only)..,,...,..,............,...,.,.,.....,,,.,,,........FL Flasher Buzzer Combination, (DC Lamps Only) ..............FL/BZ Fire Alarm Activated Flasher, (AC-Only incandescent)..........FAC Fire Alarm Activated Flasher, (Self-Powered incandescent) ..FACDC All exits are furnished complete with 2 AC lamps and. if required. 3 DC lamps. 6, 12 and 24 volt lamps are 3 watt as standard. Optional 5 watt lamps available. (Specify Suffix) Adjustable 12" Pendant For sloped ceiling (other than 12" specify length) ..P Fixed 12" Pendant For flat ceiling (other than 12" specify length) ........PF Tamperproof ..................................................................TP Wire Guard Ceiling Mount and End Mount ..................WG5 Wire Guard For Wall Mount ........................................WG12 Brushed Aluminum Face ..............................................BAF Special Exit Faces ..................................................contact factory Add Prefix Fluorescent PL7 AC Lamps............................................PL Lamp Type Fluorescent PL7 AC 15T6145 Candelabra Base DC Self-Powered Wedge Base DC Remote Powered Wedge Base Watts Cat. No. 6V 7W 12W 3W 6V 3W 6V 5W 3W 595.0010 570.0013 570.0015 570.0015 570.0012 570.0043 570.0100 570.0101 570.0072 570.0082 Voltage 120V 120V 12V 12V 24V 24V 32V 5W 3W 5W DC Remote Powered DCBB 5W (Double Contact Bayonet Base) NOTE: 6.12.24 Volt DC lamps are also available with double contact bayonet base lamps. (Suffix) (ZB) (ZB) (ZP) (ZE) (ZJ) (Zl) (ZK) (JG) How To Order AC-Only and AC/DC Exit Signs Incandescent models: include two 12 watt lamps for 120VAC operation. For 277VAC, add 277 for transformer mounted inside exit frame. AC/DC models include three additional incandescent lamps for DC operation. Fluorescent models: include two 7 watt PL lamps and two ballasts mounted inside exit frame wired for single circuit installation. Specify input voltage, 120 or 277. AC/DC models include 3 additional incandescent lamps for DC operation. R 277 MODEL EXAMPLE: 6 PL W X12 TP Face AC Input Options DC Lamp Option AC lamps Housing Color Series Stencil Face 120= 120 VAC See chart 6=6VDC Blank=lncandescent W=White X12=Single face, with canopy G=Green 277=277VAC 12=12VDC PL= Fluorescent option B=Black X14=Universal: Double face R=Red Open Face 24=24VDC with backplate and canopy RW=Red/White ADD-A-PACK 32=32VDC WR=White/Red All ' Add-A-Pack' are dual voltage 120' 277VAC for use with incandescent exit signs only. GW=Green/White To order Add-A-PackJ units specify color - white WMXAP ot black BMXAP. To order "Add-A-Pack units with (2) mounted EF-9 heads specify color - white WSRXAP or black BSRXAP WG=White/Green How To Order Self-Powered Exit Signs Incandescent models: include two 12 watt lamps for normal AC operation and three battery powered DC lamps for emergency operation. Units are 120/277 dual voltage. Fluorescent models: PL-prefix models include two 7 watt PL lamps for normal AC operation and three battery powered incandescent DC lamps for emergency operation. Units are 120/277 dual voltage. MODEL EXAMPLE: PL SMX W 14 TP R AC Lamp Housing Color Battery Options Series Face Blank=lncandescent SMX=SeaIed Lead Calcium 12=Single face, with canopy W=White See chart Stencil Face B=Black SEX=Sealed Long Life Lead PUFluorescent AC, 14=Universal: Double face R=Red G=Green with backplate and canopy Incand. emergency SNX= Sealed Nickel Cadmium Open Face RW=Red/White WR=Wnite/Red GW=Green/White WG=White/Green How To Order Self-Powered Mini Systems Exit Signs The SRX Mini System has a remote capacity of 6VDC, 18 watts. The STX Mini System has a remote capacity of 6VDC. 16 watts. Either can be used to power one or two EF9 lamps mounted on the sign or any remote load combination up to 18 watts for the SRX Mini System and 16 watts for the STX Mini System. Incandescent models: include two 12 watt lamps for normal AC operation and three battery powered DC lamps for emergency operation. Units are 120/277VAC dual input. Fluorescent models: include two 7 watt PL lamps for normal AC operation and three battery powered incandescent DC lamps for emergency operation. Units are 120/277 dual voltage. SRX PL W 11 Battery Housing Color AC Lamp Series Blank=lncandescent W=White SRX=Sealed Long LifeLead 12=Single face, with canopy PL=Fluorescent AC, B=Black STX= Sealed Nickel 14=Universal: Double face Incand. emergency with backplate and canopy Cadmium MODEL EXAMPLE: Head Mounting Choices: No Mounted Head 11) EF-9 Head R Face Stencil Face R=Red G=Green Open Face RW=Red/White WR=White/Red GW=Green/White WG=White/Green 2EF9 TP Options /of Heads 1EF9=1 Head See chart 2EF9=2 Heads Blank=No Heads (2) EF-9 Heads EMERGI-LITE 473 Bellville Road * P.O. Box 468 • St.Matthews.SC 29135 Member oi Thomas & Bens Phone (803) 874-1260 • Fax (803) 874-1262 • web site: www.emergi-lite.com FT^EMERGI-LITE • J^^h^ Member of Thomas & Betts Steel Exits Listed to Standard 924 X10 Series Incandescent/Fluorescent AC, AC/DC & Self-Powered Sealed Maintenance-Free Batteries • Nickel Cadmium PulsePlus • Long Life Lead • Lead Calcium The X10 Series is available in a variety of models with options and accessories to meet virtually any exit sign application. The removable side panel provides job site flexibility in changing signs for either single or double face requirements. A totally universal model, X14, takes all the guess work out of mounting specification. It contains two faces, a backplate and a canopy to accommodate mounting on wall or ceilings, single or double face. Damp Location Listed All AC-Only signs, both incandescent and fluorescent are U.L. Listed for use in DAMP LOCATIONS Unit Data Housing: The Housing is constructed of 20 gauge steel, with a tough epoxy powder finish in black or white. Stencil and open face have field programmable knock-out directional arrows. Light Source: Incandescent, using two 12 watt 120 VAC long life lamps. Fluorescent, using two 7 watt PL lamps with two 120 VAC ballasts, wired for single circuit installation. Choice Of Models AC-Only: 120 VAC standard, 277 VAC optional. AC/DC: 120 VAC lamps plus a choice of DC lamps standard, 277 VAC optional. Add-A-Pack: 120/277 dual voltage power packs that are used to field convert an AC or AC/DC sign into a Self-Powered model. Self-Powered: 120/277 voltage. A choice of sealed maintenance free batteries include lead calcium, long life lead and nickel cadmium, each provide 90 minutes of emergency illumination. Mini Systems: 120/277 dual voltage. Extra battery capacity in these models can be used for powering one or two heads mounted on the unit or remote fixtures up to 18 watts. Outline and Dimensions t 7 7/8" I 1 f) f> <EXIT> •«—— 121/4" ——- "t? t ' 12 I 1/2" *Unit Warranty 'Battery Warranty Canopy t 4 5/8" (Not available with Nickel Cadmium battery) We've taken our standard PulsePlus circuitry, with all its standard features, and added a diagnostic option that continuously monitors every critical function of the unit and uses five colored LED's to indicate operational status. Green. ..AC On. Amber. ..Float Charge. Red. ..Pulse Charge. Red. ..Lamp Failure. Red. ..Battery Failure. Entire unit (excluding lamps, pilot light and fuses) carries a 3-year Full Warranty. Dimensions are approximate and subject to Change. < 5 3/8"* Electrical Power Requirements: AC Incandescent: 120 VAC, 60 Hz , 24 watts. Self-Powered Incandescent: 120/277 VAC, 60 Hz., 30 watts. Output: 6 VDC. Batteries provide 90 minutes of emergency illumination. Transfer: Dust tight relay. PulsePlus Charger: Dual Diagnostic indicators, red and amber, continuously monitor the condition of the battery, charger circuit and presence of AC power. PulsePlus features include: L.V.D. low voltage disconnect circuit automatically disconnects the lamp load when the battery reaches 87-1/2% of capacity thus preventing battery deep discharge damage; Lockout, a labor saving feature that automatically connects the battery when the AC is energized; Brownout Protection, emergency lamps are energized when AC voltage falls to 85% of nominal; Temperature Compensation, in high ambient temperatures batteries need less charge voltage to prevent gassing, in low ambient temperatures batteries requires a higher charger to maintain full capacity. The PulsePlus automatically adjusts the charge voltage to precisely what the battery requires; Current Limited Output prolongs battery life; Reverse polarity protected. Controls include a test switch and LED indicator lights. o 45/8" Unit batteries are warranted as follows: Sealed Nickel Cadmium: SNX-STX- 15 year life expectancy 5-year Full Warranty, plus 7-year pro rata warranty Sealed Long Life Lead: SEX-SRX- 12 year life expectancy 5-year Full Warranty, plus 5-year pro rata warranty Sealed Lead Calcium: SMX- 8 year life expectancy 3-year Full Warranty, plus 3-year pro rata warranty -51/2"* /• ! 1/4" Subject to proper installation and maintenance. U.L. Listed to Standard 924 and Damp Location listed for AC Only Exits. Complies with OSHA. NEC. and Life Safety Code. Available with energy saving maintenance-free LED light source, refer to the X10 LED series spec sheet
© Copyright 2024