Document 217658

Options
Lamp Selection Chart
Description
Add Suffix
PulsePlus Diagnostics (Not available with Nickel Cadmium). ...PPD
Non-standard input voltage ....................................contact factory
277 Volt AC (AC and AC/DC Exit Only) ................................277
277 Volt Dual Circuit ....................................................277-2
120 Volt Dual Circuit............................;„.......,.,...„...... 120-2
Flasher (DC Lamps Only)..,,...,..,............,...,.,.,.....,,,.,,,........FL
Flasher Buzzer Combination, (DC Lamps Only) ..............FL/BZ
Fire Alarm Activated Flasher, (AC-Only incandescent)..........FAC
Fire Alarm Activated Flasher, (Self-Powered incandescent) ..FACDC
All exits are furnished complete with 2 AC lamps and. if required.
3 DC lamps. 6, 12 and 24 volt lamps are 3 watt as standard.
Optional 5 watt lamps available. (Specify Suffix)
Adjustable 12" Pendant For sloped ceiling (other than 12" specify length) ..P
Fixed 12" Pendant For flat ceiling (other than 12" specify length) ........PF
Tamperproof ..................................................................TP
Wire Guard Ceiling Mount and End Mount ..................WG5
Wire Guard For Wall Mount ........................................WG12
Brushed Aluminum Face ..............................................BAF
Special Exit Faces ..................................................contact factory
Add Prefix
Fluorescent PL7 AC Lamps............................................PL
Lamp Type
Fluorescent PL7
AC 15T6145 Candelabra Base
DC Self-Powered Wedge Base
DC Remote Powered
Wedge Base
Watts
Cat. No.
6V
7W
12W
3W
6V
3W
6V
5W
3W
595.0010
570.0013
570.0015
570.0015
570.0012
570.0043
570.0100
570.0101
570.0072
570.0082
Voltage
120V
120V
12V
12V
24V
24V
32V
5W
3W
5W
DC Remote Powered DCBB
5W
(Double Contact Bayonet Base)
NOTE: 6.12.24 Volt DC lamps are also available with double contact bayonet base lamps.
(Suffix)
(ZB)
(ZB)
(ZP)
(ZE)
(ZJ)
(Zl)
(ZK)
(JG)
How To Order AC-Only and AC/DC Exit Signs
Incandescent models: include two 12 watt lamps for 120VAC operation. For 277VAC, add 277 for transformer mounted inside
exit frame. AC/DC models include three additional incandescent lamps for DC operation.
Fluorescent models: include two 7 watt PL lamps and two ballasts mounted inside exit frame wired for single circuit installation.
Specify input voltage, 120 or 277. AC/DC models include 3 additional incandescent lamps for DC operation.
R
277
MODEL EXAMPLE:
6
PL
W
X12
TP
Face
AC Input
Options
DC Lamp Option
AC lamps
Housing Color
Series
Stencil Face
120= 120 VAC See chart
6=6VDC
Blank=lncandescent
W=White
X12=Single face, with canopy
G=Green 277=277VAC
12=12VDC
PL= Fluorescent option
B=Black
X14=Universal: Double face R=Red
Open Face
24=24VDC
with backplate and canopy
RW=Red/White
ADD-A-PACK
32=32VDC
WR=White/Red
All ' Add-A-Pack' are dual voltage 120' 277VAC for use with incandescent exit signs only.
GW=Green/White
To order Add-A-PackJ units specify color - white WMXAP ot black BMXAP.
To order "Add-A-Pack units with (2) mounted EF-9 heads specify color - white WSRXAP or black BSRXAP
WG=White/Green
How To Order Self-Powered Exit Signs
Incandescent models: include two 12 watt lamps for normal AC operation and three battery powered DC lamps for emergency
operation. Units are 120/277 dual voltage.
Fluorescent models: PL-prefix models include two 7 watt PL lamps for normal AC operation and three battery powered
incandescent DC lamps for emergency operation. Units are 120/277 dual voltage.
MODEL EXAMPLE:
PL
SMX
W
14
TP
R
AC Lamp
Housing Color
Battery
Options
Series
Face
Blank=lncandescent
SMX=SeaIed Lead Calcium
12=Single face, with canopy
W=White
See chart
Stencil Face
B=Black
SEX=Sealed Long Life Lead
PUFluorescent AC,
14=Universal: Double face
R=Red
G=Green
with backplate and canopy
Incand. emergency
SNX= Sealed Nickel Cadmium
Open Face
RW=Red/White
WR=Wnite/Red
GW=Green/White
WG=White/Green
How To Order Self-Powered Mini Systems Exit Signs
The SRX Mini System has a remote capacity of 6VDC, 18 watts. The STX Mini System has a remote capacity of 6VDC. 16 watts.
Either can be used to power one or two EF9 lamps mounted on the sign or any remote load combination up to 18 watts for the
SRX Mini System and 16 watts for the STX Mini System.
Incandescent models: include two 12 watt lamps for normal AC operation and three battery powered DC lamps for emergency
operation. Units are 120/277VAC dual input.
Fluorescent models: include two 7 watt PL lamps for normal AC operation and three battery powered incandescent DC lamps
for emergency operation. Units are 120/277 dual voltage.
SRX
PL
W
11
Battery
Housing Color
AC Lamp
Series
Blank=lncandescent
W=White
SRX=Sealed Long LifeLead 12=Single face, with canopy
PL=Fluorescent AC,
B=Black
STX= Sealed Nickel
14=Universal: Double face
Incand. emergency
with backplate and canopy
Cadmium
MODEL EXAMPLE:
Head
Mounting
Choices:
No Mounted Head
11) EF-9 Head
R
Face
Stencil Face
R=Red
G=Green
Open Face
RW=Red/White
WR=White/Red
GW=Green/White
WG=White/Green
2EF9
TP
Options
/of Heads
1EF9=1 Head See chart
2EF9=2 Heads
Blank=No Heads
(2) EF-9 Heads
EMERGI-LITE 473 Bellville Road * P.O. Box 468 • St.Matthews.SC 29135
Member oi Thomas & Bens
Phone (803) 874-1260 • Fax (803) 874-1262 • web site: www.emergi-lite.com
FT^EMERGI-LITE
• J^^h^
Member of Thomas & Betts
Steel Exits
Listed to
Standard 924
X10 Series
Incandescent/Fluorescent
AC, AC/DC & Self-Powered
Sealed Maintenance-Free Batteries
• Nickel Cadmium
PulsePlus
• Long Life Lead
• Lead Calcium
The X10 Series is available in a variety of models with options
and accessories to meet virtually any exit sign application. The
removable side panel provides job site flexibility in changing
signs for either single or double face requirements. A totally
universal model, X14, takes all the guess work out of mounting
specification. It contains two faces, a backplate and a canopy to
accommodate mounting on wall or ceilings, single or double face.
Damp Location Listed
All AC-Only signs, both incandescent and fluorescent are U.L.
Listed for use in DAMP LOCATIONS
Unit Data
Housing: The Housing is constructed of 20 gauge steel, with a
tough epoxy powder finish in black or white. Stencil and open
face have field programmable knock-out directional arrows.
Light Source: Incandescent, using two 12 watt 120 VAC long
life lamps. Fluorescent, using two 7 watt PL lamps with two 120
VAC ballasts, wired for single circuit installation.
Choice Of Models
AC-Only: 120 VAC standard, 277 VAC optional.
AC/DC: 120 VAC lamps plus a choice of DC lamps standard,
277 VAC optional.
Add-A-Pack: 120/277 dual voltage power packs that are used to
field convert an AC or AC/DC sign into a Self-Powered model.
Self-Powered: 120/277 voltage. A choice of sealed
maintenance free batteries include lead calcium, long life lead
and nickel cadmium, each provide 90 minutes of emergency
illumination.
Mini Systems: 120/277 dual voltage. Extra battery capacity in
these models can be used for powering one or two heads
mounted on the unit or remote fixtures up to 18 watts.
Outline and Dimensions
t
7 7/8"
I
1
f)
f>
<EXIT>
•«—— 121/4" ——-
"t?
t '
12
I
1/2"
*Unit Warranty
'Battery Warranty
Canopy
t
4 5/8"
(Not available with Nickel Cadmium battery)
We've taken our standard PulsePlus circuitry, with all its
standard features, and added a diagnostic option that
continuously monitors every critical function of the unit and
uses five colored LED's to indicate operational status.
Green. ..AC On. Amber. ..Float Charge. Red. ..Pulse Charge.
Red. ..Lamp Failure. Red. ..Battery Failure.
Entire unit (excluding lamps, pilot light and fuses) carries a
3-year Full Warranty.
Dimensions are approximate and subject to Change.
< 5 3/8"*
Electrical
Power Requirements:
AC Incandescent: 120 VAC, 60 Hz , 24 watts.
Self-Powered Incandescent: 120/277 VAC, 60 Hz., 30 watts.
Output: 6 VDC. Batteries provide 90 minutes of emergency
illumination.
Transfer: Dust tight relay.
PulsePlus Charger: Dual Diagnostic indicators, red and amber,
continuously monitor the condition of the battery, charger circuit
and presence of AC power. PulsePlus features include: L.V.D.
low voltage disconnect circuit automatically disconnects the
lamp load when the battery reaches 87-1/2% of capacity thus
preventing battery deep discharge damage; Lockout, a labor
saving feature that automatically connects the battery when the
AC is energized; Brownout Protection, emergency lamps are
energized when AC voltage falls to 85% of nominal;
Temperature Compensation, in high ambient temperatures
batteries need less charge voltage to prevent gassing, in low
ambient temperatures batteries requires a higher charger to
maintain full capacity. The PulsePlus automatically adjusts the
charge voltage to precisely what the battery requires; Current
Limited Output prolongs battery life; Reverse polarity protected.
Controls include a test switch and LED indicator lights.
o
45/8"
Unit batteries are warranted as follows:
Sealed Nickel Cadmium: SNX-STX- 15 year life expectancy
5-year Full Warranty, plus 7-year pro rata warranty
Sealed Long Life Lead: SEX-SRX- 12 year life expectancy
5-year Full Warranty, plus 5-year pro rata warranty
Sealed Lead Calcium: SMX- 8 year life expectancy
3-year Full Warranty, plus 3-year pro rata warranty
-51/2"*
/•
! 1/4"
Subject to proper installation and maintenance.
U.L. Listed to Standard 924 and Damp Location listed for AC Only Exits. Complies with OSHA. NEC. and Life Safety Code.
Available with energy saving maintenance-free LED light source, refer to the X10 LED series spec sheet