@ CD-8241B June 2001 Beckman Coulter Capillary Electrophoresis Supplies, Accessories & Options PUTTING CE TO WORK CHIRAL A N A LYS I S Contents Index Navigation & Information D RU G SCREENING C A R B O H Y D R AT E A N A LYS I S P ROT E I N C H A R AC T E R I Z AT I O N GENETIC A N A LYS I S B E C K M A N C O U LT E R Capillary Electrophoresis B eckman Instruments, Inc., was founded by Dr. Arnold O. Beckman in 1935 with the invention of the pH meter, a project initiated from a colleague’s need to monitor the acidity of citrus juice. Since then, Beckman Coulter has grown into a 1.8 billion-dollar corporation with many scientific firsts to its credit. Commercial electrophoresis systems were first introduced by Beckman in 1953 with the development of the Model H, a Tiselius cell with Schlieren photography and advanced optics. Since that time electrophoresis has played an important role in Beckman’s bioresearch and clinical diagnostic developments. Beckman’s contributions to capillary electrophoresis (CE) began in 1989 with the launch of the P/ACE 2000. This instrumentation boasted many CE firsts including a cartridge design with liquid thermostating of the capillary, micropreparative fraction collection and automated personal computer control. Since the introduction of the P/ACE, Beckman Coulter has been the acknowledged leader in the development of CE technology with advancements in hardware, software and chemistry. These advancements included laser-induced fluorescence, diode-array detection, independent sample and buffer temperature control, advanced CE data reduction and a myriad of CE chemistries. These advancements soon moved from generic CE to applied instrumentation first seen with the release of the Paragon CZE 2000, a multi-capillary system for automated serum protein analysis in clinical diagnostics. This was soon followed by the P/ACE MDQ, a rugged line of instrumentation for pharmaceutical/biotechnology methods development and quality control. The CEQ 2000XL, a multi-capillary fully automated DNA Sequencing System, the dual-wavelength P/ACE MDQ LIF detection system, and the P/ACE MDQ-LCQ CE-MS/MS system are the newest additions. Beckman Coulter continues to lead the field of capillary electrophoresis, strongly committed to further CE research and development. Our direction is guided by you, to apply this core technology to systems providing key analytical solutions. Beckman Coulter Contents Index 2 1989 1990 1991 P/ACE Introduction Improved UV Detection Gold Software for CE eCAP ssDNA 100 Kit B E C K M A N C O U LT E R I N N OVAT I O N S 1992 IN C APILLARY Laser-Induced Fluorescence Detection Molecular Weight Software CE-MS Adapter eCAP SDS 200 Protein Kit Sample Cooling Isoelectric Focusing Capability Enhanced Sensitivity Cartridge Diode Array Detection P/ACE 5000 eCAP SDS 14-200 Protein Kit eCAP dsDNA 20,000 Kit eCAP cIEF 3-10 Kit 635 Laser Module The Chiral Solution Paragon CZE 2000 Serum Protein Analyzer P/ACE MDQ Quality Control System P/ACE MDQ Methods Development System P/ACE MDQ Chiral Analysis System P/ACE 5000 Series Education System MDQ Kits APTS Monosaccharide Grade P/ACE MDQ Dual λ LIF P/ACE MDQ Glycoprotein System P/ACE MDQ Carbohydrate System P/ACE MDQ DNA System 32 Karat Software Version 4.0 CEQ 2000XL Longer Faster Reads CEQ Chem Kit DTCS – Quick Start Chemistries CEQ 2000XL Automated Heterozygote Detection eCAP Carbohydrate Labeling Kit 1993 ELECTROPHORESIS eCAP dsDNA 1000 Kit 1994 eCAP Amine Capillary Methods Development Kit– Small Molecules 1995 eCAP Amine Capillary Methods Development Kit– Proteins eCAP Neutral Capillary Methods Development Kit/Proteins eCAP Chiral Methods Development Kit 1997 1996 eCAP N-Linked Oligosaccharide Profiling Kit LIFluor dsDNA 1000 Kit eCAP ssDNA 100-R Kit The Carbohydrate Solution The DNA Solution P/ACE Station Software P/ACE MDQ 1999 1998 NH2- -O3S -O3S SO3APTS Highly Sulfated Cyclodextrins HS CD External Detector Adapter 1.6 Software Enhancement CEQ 2000 DNA Sequencer 2000 P/ACE MDQ-LCQ CE-MS/MS System Beckman Coulter Contents Index 3 CAPILLARY ELECTROPHORESIS A SIMPLE TECHNIQUE Capillary electrophoresis (CE) is a family of related separation techniques that use narrow-bore fusedsilica capillaries to separate a complex array of large and small molecules. High voltages are used to separate molecules based on differences in charge, size and hydrophobicity. Injection into the capillary is accomplished by immersing the end of the capillary into a sample vial and applying pressure, vacuum or voltage. Depending on the types of capillary and buffers, CE can be segmented into several separation techniques. Examples of these include: CAPILLARY ZONE ELECTROPHORESIS (CZE), also known as free-solution CE (FSCE), is the simplest form of CE. The separation mechanism is based on differences in the charge-to-mass ratio of the analytes. Fundamental to CZE are homogeneity of the buffer solution and constant field strength throughout the length of the capillary. The separation relies principally on the pHcontrolled dissociation of acidic groups on the solute or the protonation of basic functions on the solute. CAPILLARY GEL ELECTROPHORESIS (CGE) is the adaptation of traditional gel electrophoresis into the capillary using polymers in solution as a molecular sieve. This allows solutes having similar charge-to-mass ratios to be resolved by size. CAPILLARY ISOELECTRIC FOCUSING (CIEF) allows amphoteric molecules, such as proteins, to be separated by electrophoresis in a pH gradient generated between the cathode and anode. A solute will migrate to a point where its net charge is zero. At this isoelectric point (the solute’s pI), migration stops and the sample is focused into a tight zone. In cIEF, once a solute has focused at its pI, the zone is mobilized past the detector by either pressure or chemical means. ISOTACHOPHORESIS (ITP) is a focusing technique based on the migration of the sample components between leading and terminating electrolytes. Solutes having mobilities intermediate to those of the leading and terminating electrolytes stack into sharp, focused zones. Although it is used as a mode of separation, transient ITP has been used primarily as a concentration technique. ELECTROKINETIC CHROMATOGRAPHY (EKC) is a family of electrophoresis techniques named after electrokinetic phenomena, which include electroosmosis, electrophoresis and chromatography. A key example of this is seen with cyclodextrin-mediated EKC. Here the differential interaction of enantiomers with the cyclodextrins in combination with an electrophoretic field allows for the separation of chiral compounds. MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY (MECC OR MEKC) is a mode of electrokinetic chromatography in which surfactants are added to the buffer solution at concentrations which form micelles. The separation principle of MEKC is based on a differential partition between the micelle and the solvent. This principle can be employed with charged or neutral solutes and may involve stationary or mobile micelles. MEKC has great utility in separating mixtures which contain both ionic and neutral solutes. CAPILLARY ELECTROCHROMATOGRAPHY (CEC) is a hybrid separation method that couples the high separation efficiency of CZE with HPLC, and uses an electric field rather than hydraulic pressure to propel the mobile phase through a packed bed. Since there is minimal backpressure, it is possible to use small-diameter packings and achieve very high efficiencies. NON-AQUEOUS CAPILLARY ELECTROPHORESIS (NACE) involves the separation of analytes in a medium composed of organic solvents. The viscosity and dielectric constants of organic solvents affect both sample ion mobility and the level of electroosmotic flow. The use of non-aqueous medium allows additional selectivity options in methods development and is also valuable for the separation of waterinsoluble compounds. ` Summary Block diagram of basic CE system. The magnified view depicts the capillary interior with molecules of different size and charge separating. As illustrated, in free-solution capillary electrophoresis, the positive molecules migrate toward the negative electrode while the electroosmotic flow carries the neutral and negatively charged molecules in the same direction. Beckman Coulter Contents The large selection of separation mechanisms combined with its “in solution” approach has allowed capillary electrophoresis to excel where many analytical techniques have failed. CE has been successful primarily with complex hydrophilic macromolecules and highly charged solutes. These techniques have led to the rapid separation and quantitation of: • Nucleic Acids • Proteins • Glycoproteins • Peptides • Carbohydrates • Basic Pharmaceuticals • Chiral Isomers • Inorganic and Organic Ions Index 4 THE BECKMAN COULTER FAMILY OF CE SYSTEMS Beckman Coulter’s history, knowledge and leadership in Capillary Electrophoresis has lead to the creation of the P/ACE and CEQ product lines. From its first commercial instrument shipment in 1989, Beckman Coulter’s leadership has established the largest productive base of CE instruments and users in the world. CE product development has been guided by suggestions from this large customer base as well as collaborative work with experts in the field. The present CE family is the result of these efforts. SUMMARY The P/ACE Series are automated, programmable capillary electrophoresis systems designed to perform fast separations from complex samples. Separations occur in a capillary which is housed in an interchangeable cartridge with circulating liquid coolant for efficient temperature control. This finely regulated temperature control allows the use of highionic-strength buffers and large-bore capillaries necessary for analyzing difficult samples. With CE, methods are fast to develop, easy to validate, and cost effective to run. However, specialized system designs are required to optimize performance for different applications. To address these needs, Beckman offers a family of CE instruments developed to apply CE technology to a variety of challenging applications. Each system includes components necessary to begin immediate operation, such as vials, capillaries, and test mix. All systems include installation and basic training by qualified Field Service Engineers. B E C K M A N C O U LT E R C E S YS T E M S P/ACE MDQ QUALITY CONTROL SYSTEM P/ACE MDQ METHODS DEVELOPMENT SYSTEM P/ACE MDQ CHIRAL A N A LY S I S SYSTEM P/ACE MDQ G LY C O P R O T E I N A N A LY S I S SYSTEM P/ACE MDQ DNA SYSTEM CEQ 2000XL DNA SEQUENCER TA B L E OF P/ACE MDQ-LCQ CE-MS/MS P A R A G O N ®® CZE 2000 S ERUM P R OTEIN A NALYZER NALYZER CONTENTS P/A C E M D Q S Y S T E M S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 P /A C E M D Q AND CEQ SYSTEMS ...........................9 P/A C E M D Q M O D U L E S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0 D E T E C TO R O P T I O N S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 P / A C E M D Q / 5 0 0 0 S E R I E S D E T E C TO R A C C E S S O R I E S . . . 1 2 C E S Y S T E M S O F T WA R E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4 CE SUPPLIES ................................................15 C E A P P L I C AT I O N K I T S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 C E C H E M I S T RY K I T S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 5 L A B WA R E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 8 CE SUPPLIES AND L A B WA R E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 0 C U S TO M E R S U P P O RT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 C A P I L L A RY E L E C T R O P H O R E S I S E D U C AT I O N A L A I D S . . . . . . . 4 4 T E C H N I C A L & A P P L I C AT I O N I N F O R M AT I O N . . . . . . . . . . . . . . . . 4 6 INDEX ........................................................50 Beckman Coulter Index 5 P/ACE MDQ ™ he P/ACE™ MDQ is an advanced CE system designed, in terms of flexibility and capacity, to meet the different requirements of research, methods development and quality control laboratories. Each configuration is available with a series of options to customize to meet end-user requirements. All P/ACE MDQ configurations combine hardware, software and chemistry with worldwide technical support. A choice of interchangeable detectors meets the needs of a wide range of applications. The software automates all operations, from direct instrument control to data acquisition, analysis and reporting. At the heart of the MDQ is the system’s flexibility in programming and capacity. In methods development, samples can be automatically run against an array of up to 36 different pairs of buffers, while in quality control the buffer array can be switched for buffer capacity (large volume reservoir) enabling routine analysis of up to 96 samples. The P/ACE MDQ works with a range of sample vessels accommodating 96-well plates or a 48-position tray that holds 2 mL vials, 0.5 mL tubes and PCR* reaction vials. The system’s built in software features assist in meeting GLP and CGMP compliance requirements. P/ACE MDQ is specially designed to meet industry’s demands for ruggedness and safety. Beckman Coulter validates system performance upon installation and provides a comprehensive compliance protocol. T * PCR is covered by U.S. patents owned by Hoffmann-La Roche Inc. P/ACE MDQ Methods Development System PART N UMBER PART N UMBER 149817 North America International 285400 A CE-based analytical system configured optimally for the methods development process, where a focus is placed on spectral analysis and the automation of separation strategies. The system includes a P/ACE MDQ configured with both a photo diode array and selectable-wavelength UV/Vis (200, 214, 254 and 280 nm filters included) detector, UV source optics, temperature-controlled sample storage module and 32 Karat™ Software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included. Starter chemistries: P/ACE MDQ Methods Development Kit, Amine Capillary Validation Pack and the Neutral Capillary Validation Pack. P/ACE MDQ Chiral System PART N UMBER PART N UMBER 149833 North America International 285402 A CE-based analytical system configured optimally for developing methods for the separation of enantiomers. The system includes a P/ACE MDQ configured with a photo diode array detector, UV source optics, ambient sample storage module and 32 Karat software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included. Starter chemistries: The Highly Sulfated Cyclodextrins chiral methods development pack (strategy # 1), Neutral CD Chiral Methods Development Kit (strategy #2), and Chiral Methods Development Guide. P/ACE MDQ Quality Control System PART N UMBER PART N UMBER 149815 North America International 285401 A CE-based analytical system configured optimally for the quality assurance laboratory. With a focus on repetitive robust analyses, the system includes a P/ACE MDQ configured with a filter-based selectablewavelength UV/Vis (200, 214, 254 and 280 nm included) detector, UV source optics, ambient sample storage module, and 32 Karat Software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1), and documentation to aid in software validation are also included. Beckman Coulter Contents Index 6 P/ACE MDQ ™ P/ACE™ MDQ-LCQ CE-MS/MS Systems PART N UMBER PART N UMBER 149016 These systems feature single-point control of both the ThermoFinnigan LCQ and the Beckman Coulter P/ACE MDQ using the Xcalibur™ workstation. The P/ACE MDQ is configured with diode array detection, sample tray temperature control, and capillary temperature control extended to an electrospray interface. The unique system interface employs a liquid sheath make-up flow to sweep the analytes off the capillary and into the mass spectrometer. The LCQ utilizes ion trap technology to resolve the molecular ions and is capable of MS/MS— allowing these ions to be isolated and further fragmented to gain structural information and higher confidence confirmation. These systems have been optimized for capillary lengths and instrument levels—and configured for the following three applications (please contact your local Beckman Coulter representative for a quotation on the following systems): 1) CE-MS/MS Protein Characterization System 2) CE-MS/MS Pharmaceutical Analysis System 3) CE-MS/MS Research System P/ACE MDQ Glycoprotein System PART N UMBER PART N UMBER 149893 North America International 149872 CE-based system for the separation and characterization of proteins and associated carbohydrates. The system is ideal for peptide mapping, separation of proteins by molecular weight, accurate isoelectric point (pI) determination, oligosaccharide profiling and monosaccharide analysis. System includes a P/ACE MDQ configured with a selectable wavelength UV/Vis (200, 214, 254 and 280 nm included) detector, UV source optics, laser-induced fluorescence detector, 488 nm argon ion laser module, a temperature-controlled sample storage module, and 32 Karat™ Software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included. Starter chemistries: eCAP™ Carbohydrate Labeling and Analysis Kit, eCAP SDS 14-200 Kit, MDQ Methods Development kit, LIF and UV detector test mix, and Glycoprotein Methods Development Guide. Beckman Coulter Contents Index 7 P/ACE MDQ ™ P/ACE™ MDQ Molecular Characterization System PART N UMBER PART N UMBER 149891 North America International 149863 A CE-based system for the analysis of nucleic acids and their subsequent interactions with proteins. The system provides clear advantages over traditional electrophoresis for DNA quantitation (viral load, gene expression), synthetic oligonucleotide purity analysis, mutation analysis, size polymorphisms analysis (VNTR, STR, microsatellites, RFLP, RAPD) and the study of DNA/protein interactions. System includes a P/ACE MDQ configured with a selectable-wavelength UV/Vis (200, 214, 254 and 280 nm included) detector, UV source optics, dualwavelength laser-induced fluorescence detector, 488 nm argon ion laser module, a temperature-controlled sample storage module, and 32 Karat™ Software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included. Starter chemistries: P/ACE MDQ Methods Development Kit, eCAP™ ssDNA 100 kit, eCAP dsDNA 1000 kit, eCAP dsDNA 20,000 kit, EnhanCE™ DNA intercalator, LIF and UV detector test mix, and Molecular Characterization Applications Guide. P/ACE™ MDQ Carbohydrate System PART N UMBER PART N UMBER 149890 North America International 149896 2.0 Man Nac from Neu5Ac A 0.1 N TFA hydrolyzed Aldolase treated GlcNAc B 1.0 Man GalNAc Gal 2.0 N TFA hydrolyzed Reacetylated R GalNAc GlcNAc Man Glc Fuc Gal Standard Six monosaccharides 2.00 4.00 Beckman Coulter 6.00 8.00 10.00 A CE-based system for the separation and analysis of carbohydrates. The system is ideal for both oligosaccharide profiling and monosaccharide analysis. System includes a P/ACE MDQ configured with a laser-induced fluorescence detector, 488 nm argon ion laser module, an ambient sample storage module, and 32 Karat™ Software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included. Starter chemistries: eCAP™ Carbohydrate Labeling and Analysis Kit and Carbohydrate Methods Development Guide. Contents Index 8 P/ACE MDQ AND CEQ SYSTEMS ™ ™ P/ACE MDQ DNA System PART N UMBER PART N UMBER 149892 North America International 149874 A CE-based system for the analysis of nucleic acids. The system provides clear advantages over traditional electrophoresis for DNA quantitation (viral load, gene expression), mutation analysis, and size polymorphisms analysis (VNTR, STR, microsatellites, RFLP, RAPD). System includes a P/ACE MDQ configured with a laser-induced fluorescence detector, 488 nm argon ion laser module, an ambient sample storage module, and 32 Karat Software configured on an IBM personal computer. Installation Qualification, Operation Qualification 1 (OQ1) and documentation to aid in software validation is also included. Starter chemistries: eCAP dsDNA 1000 kit, eCAP dsDNA 20,000 kit, EnhanCE DNA intercalator, LIF detector test mix, and Nucleic Acids Methods Development Guide. C E Q ™ 2 0 0 0 X L D N A A N A LY S I S S Y S T E M The CEQ 2000XL DNA Analysis System is a fully automated, high-throughput sequencing and fragment analysis system. Capillary electrophoresis technology and laser-induced fluorescence detection have been combined to provide a very easy to use microplatebased system. The CEQ is designed to handle all aspects of the DNA analysis process from sample denaturation through automatic base or allele calling, with no user intervention, following an easy ten minute setup. KEY FEATURES OF THE CEQ 2000XL • Linear Polyacrylamide Gel matrix inside a coated capillary array provides the best read length/cycle time and the highest accuracy of any CE-based sequencer. • Eight capillary array to eliminate plate cleaning, gel casting, and tedious DNA sample loading. • 96-well microplate format. • Automated: loading of separation gel, sample denaturation, and sample loading. • Automatically switches between sequencing applications and fragment analysis on the same plate. For Sequencing: • Longer reads and faster cycle times (>700 bases in less than 100 minutes at better than 98% accuracy). • Short reads and faster cycle times (>500 bases in less than 45 minutes at better than 98% accuracy). • Dideoxy-terminator cycle sequencing kits with four “WellRED” fluorescence dyes (one-tube chemistry). • Raw data and analyzed data available in most popular formats. • Confidence values and call scores provided with each base determined. For Fragment Analysis: • Automated allele determination. • Precisely sized microsatellite amplification products to a S.D. of ≤0.27 bases. PART N UMBER 285501 Worldwide The CEQ 2000XL DNA analysis system is a fully automated, highperformance sequencing and fragment analysis system, employing an eight-capillary array to increase sample throughput, and specialized laser-induced fluorescence detection optics with WellRED dyes (infrared emission) for unsurpassed performance in dideoxy terminator cycle sequencing. Sample introduction is done directly from a 96-well microplate, compatible with most forms of sample prep automation. The CEQ 2000XL handles all aspects of the DNA analysis process, from sample denaturation through automatic base or allele calling with no user intervention. This system includes the CEQ 2000XL instrument, software for both sequencing and fragment analysis, an IBM workstation, installation and basic training. Beckman Coulter Contents Index 9 P/ACE MDQ MODULES ™ T he following instruments are packaged with appropriate shipping kits to ensure rapid installation, but they do not include computer workstations, software or accessories. See previous section for complete packages. The purpose of these systems is to allow you to purchase basic modules to add on to existing systems. PART N UMBER D ESCRIPTION 144000 P/ACE™ MDQ – PDA Includes P/ACE MDQ with photodiode array detector and ambient sample storage module. 144001 P/ACE MDQ – UV Ambient Includes P/ACE MDQ with UV/Vis detector and ambient sample storage module. 144002 P/ACE MDQ – PDA – Sample Temp. Control Includes P/ACE MDQ with Diode Array Detector and temperaturecontrolled sample storage module. 144003 P/ACE MDQ – UV – Sample Temp. Control Includes P/ACE MDQ with UV/Vis detector and temperature-controlled sample storage module. Beckman Coulter Contents Index 10 DETECTOR OPTIONS P/A C E™ M D Q D E T E C T O R S Beckman Coulter believes that an analytical instrument should be able to evolve to meet changing requirements. The following detector modules are plug-in units that are easy to switch once they are installed. PART N UMBER D ESCRIPTION 144733 P/ACE™ MDQ UV/Vis Detector Module Consists of UV/Vis detector, UV optics cable, 200 nm, 214 nm, 254 nm, and 280 nm filters. 149819 P/ACE MDQ Diode Array Detector Upgrade Kit Consists of DAD detector, DAD optics cable, and DAD board. 149852 P/ACE MDQ External Detector Adapter (EDA) Accessory Kit Complete kit for the addition of EDA to MDQs shipped with version 1.5 software and higher. These MDQs will already have EDA-compatible hardware and firmware. Kit also includes a hydraulic leveling table. Service installation included. 144954 P/ACE MDQ Dual λ LIF Detector Includes LIF Dual Detector Module, Interconnect Module, LIF Cartridge Plug and Stabilizer. Allows two emission wavelengths to be detected simultaneously. For further information, see DS-8284A. 144901 P/ACE MDQ Single λ LIF Detector Includes LIF Detector Module, Interconnect Module, LIF Cartridge Plug and Stabilizer. Laser Modules Beckman Coulter 727620 Argon Ion – 488 nm (120 V) 727621 Argon Ion – 488 nm (220 V) 727622 Argon Ion – 488 nm (240 V) 727619 Argon Ion – 488 nm (100 V) 267839 635 nm Diode Laser Contents Index 11 P/ACE MDQ/5000 SERIES DETECTOR ACCESSORIES ™ PART N UMBER D ESCRIPTION LIF Detector Filters for P/ACE™ 5000 Series 360672 961640 960323 890880 890879 725412 LIF Detector Filter Holder LIF 488 nm Notch Filter LIF 520 nm Emission Bandpass Filter LIF 530 nm Emission Bandpass Filter LIF 560 nm Emission Bandpass Filter LIF 675 nm Emission Bandpass Filter UV Filters Filters can be purchased for replacement or custom applications and are customer installed. These filters are compatible with both the P/ACE 5000 and the P/ACE MDQ instruments. 144430 144431 144437 144432 144433 144438 144434 144439 144435 144436 Filter, 200 nm Filter, 210 nm Filter, 214 nm Filter, 220 nm Filter, 230 nm Filter, 254 nm Filter, 260 nm Filter, 280 nm Filter, 300 nm Filter, 340 nm LIF Detector Filters for P/ACE MDQ Series 144941 144940 144942 Beckman Coulter Contents 488 nm Notch Filter 520 nm Bandpass Filter 663 nm Longpass Filter Index 12 P/ACE MDQ/5000 SERIES DETECTOR ACCESSORIES ™ Miscellaneous Supplies PART N UMBER D ESCRIPTION 360671 LIF Fiber-Optic Cable for Laser with SMA905 Connector (quantity 1) 726022 LIF Test Mix, Sodium Fluorescein (20 mL) 477615 635 LIF Calibration/Test Standard 144667 Deuterium Lamp Assembly, P/ACE™ MDQ Replacement part (quantity 1). 142205 Deuterium Lamp Assembly, P/ACE 5000 Series Replacement part (quantity 1). 359058 Deuterium Lamp Assembly, P/ACE 2000 Series Replacement part (quantity 1). Beckman Coulter 144093 Replacement UV/Vis Fiber Optic Cable for the P/ACE MDQ 144094 Replacement DAD Fiber Optic Cable for the P/ACE MDQ Contents Index 13 CE SYSTEM SOFTWARE 3 2 K A R AT ™ S O F T WA R E AND WO R K S TAT I O N S 32 Karat™ software is a new platform for P/ACE™ MDQ system control, data collection, and analysis. This new platform was developed entirely in 32-bit code to fully utilize the functionality of the Windows* NT and Windows 2000 operating systems. 32 Karat software preserves data integrity with features such as user-specific log-in, independent audit trails, and results sign-off— ideal for research, biotechnology, or pharmaceutical laboratories. 32 Karat software adds analysis dimensions that significantly increase the accuracy of compound identification. New Peak identification algorithms allow the P/ACE MDQ to combine an analyte’s mobility with spectral information for accurate identification against a large database of compounds. Data may also be plotted as a function of either migration time or mobility. Each 32 Karat workstation is capable of running up to four P/ACE MDQ systems with multiple channels. 32 Karat software has been developed using documented processes and is fully validated at Beckman Coulter. The 32 Karat Workstation includes a computer platform that has been validated by Beckman Coulter for the operation of 32 Karat software. PART N UMBER D ESCRIPTION 285510 32 Karat Workstation for P/ACE MDQ Includes 32 Karat software installed on an IBM computer with Windows NT software. Six hours of user training are also included. Contact Beckman Coulter sales for the current computer configuration. 285512 32 Karat Software (User Installed) Includes 32 Karat software and six hours of user training. Requires a compatible computer platform (please contact your local Beckman Coulter representative). 285511 32 Karat Workstation – Migration Upgrade Includes 32 Karat software installed on an IBM computer with Windows NT software. A migration guide to assist you in moving your data and methods from the P/ACE MDQ software to 32 Karat software and 6 hours of user training are included. This migration offer requires you to return your existing P/ACE MDQ software key to Beckman Coulter (please contact your local Beckman Coulter representative). 285514 32 Karat Software – Migration Upgrade (User Installed) Includes 32 Karat software and six hours of user training. Requires a compatible computer platform (please contact your local Beckman Coulter representative). A migration guide to assist you in moving your data and methods from the P/ACE MDQ software to 32 Karat software and 6 hours of user training are included. This migration offer requires you to return your existing P/ACE MDQ software key to Beckman Coulter. 149948 32 Karat Software Reprocessing Key Allows reprocessing of data collected on 32 Karat software at a remote or network location (does not provide instrument control). 149989 32 Karat Software Validation Pack System requirements, specifications, intended use, development life cycle quality programs, and validation process are documented, allowing this information to be used as a “remote audit” to support the validation of Beckman Coulter COTS (Commercial Off-The-Shelf) analytical software. Site audits at Beckman Coulter in Fullerton are also available. PC Accessory Pak Includes keyboard (local language version), monitor and PC power cords. 144930 144931 144932 144933 144934 Beckman Coulter Contents French Version German Version Italian Version Spanish Version U.K. Version Index 14 CE SUPPLIES CAPILLARIES All methods development in CE begins with the choice of the correct capillary surface. The goal is to choose a surface which will not interact with the sample and, depending upon the application, one which will either reduce or induce electroosmotic flow. Beckman Coulter offers a choice of several types of capillaries, which range in surface chemistry allowing a variety of samples to be analyzed including pharmaceuticals, industrial chemicals, chiral drugs, nucleic acids, amino acids, proteins and peptides. These capillaries are available in defined lengths, which may be trimmed to optimize instrument type, speed and resolution. NEUTRAL SURFACES Neutral surfaces are designed to coat the exposed silanol groups on the fused silica and serve two major functions: 1) to reduce electroosmotic flow, and 2) to prevent wall interaction with the sample. However, not all neutral surfaces are the same and it is important to understand what the surface is composed of to ensure that other interactions (i.e., hydrophobic) do not replace the ionic interactions you are trying to reduce. For example, when using a neutral capillary with a surface consisting of a hydrophobic bonded phase, it is essential to include hydrophilic polymers in the buffer to prevent hydrophobic interactions. The following is a list of neutral surfaces that are available from Beckman Coulter. All of these surfaces are bi-layers, consisting first of a bonded phase to shield the silanol groups followed by a hydrophilic polymer to prevent hydrophobic interaction. PART NUMBER DESCRIPTION eCAP™ Neutral Capillary, 50 µm I.D., 45 cm total length, 12 cm from window to outlet (quantity 1) The neutral capillary utilizes a secondary layer of polyacrylamide to generate a hydrophilic surface. This is a general purpose capillary, which Beckman Coulter recommends as a starting point for handling complex samples like proteins or basic molecules. Polyacrylamide surfaces are recommended for use with both UV and LIF detection systems but may show some reduction in capillary life with diodearray detection systems. 477441 eCAP N-CHO Capillary, 50 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) The N-CHO capillary utilizes a secondary layer composed of polyvinyl alcohol (PVA). This surface is ideal for the separation of complex samples like proteins or basic pharmaceuticals in cases where minimal EOF is desired. PVA is a very rugged surface, which is stable with UV, LIF and diode array detection systems. However, due to the chemical nature of PVA, it is not recommended for use with borate buffer systems, as the borate ion will complex with the surface. This capillary has been featured in the Carbohydrate Labeling and Analysis Kit (P/N 477600). 477601 Beckman Coulter Contents Index 15 CE SUPPLIES NEUTRAL SURFACES (CONTINUED) PART NUMBER DESCRIPTION 241521 eCAP™ Neutral Capillary (SDS-MW), 100 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) This capillary has been optimized for use with the eCAP SDS 14-200 kit (separation of proteins by molecular weight). The capillary utilizes a 100 µm I.D. which allows increased sample loads, ideal for isolation of an analyte by fraction collection. eCAP Neutral Capillary (DNA), 100 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) This capillary has been optimized for use with Beckman Coulter DNA chemistries. The capillary utilizes a 100 µm I.D. which allows increased sample loads, ideal for isolation of an analyte by fraction collection. 477477 1st and 240th runs of basic proteins on a neutral capillary. %RSD for migration time: Lysozyme—0.47%, Cytochrome C—0.51%, and Ribonuclease A—0.96%. Beckman Coulter Contents Index 16 CE SUPPLIES AMINE SURFACES Although basic compounds can be analyzed effectively at low pH, there are circumstances where one may wish to operate at a higher pH to better differentiate sample mobility, effect solubility or induce electroosmotic flow. The amine capillary was generated for this purpose. The Beckman Coulter amine capillary utilizes a dynamic coating that, by washing with the amine regenerator between runs, assures a uniform capillary coating from run to run. This capillary has been used effectively for basic proteins, basic drugs and even for the separation of glycoforms. The surface is a cross-linked polymer with a quaternary ammonium ion providing a uniform positively charged surface and a consistent electroosmotic flow. PART N UMBER 3 45 7 2 D ESCRIPTION 477431 eCAP™ Amine Capillary, 50 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) This capillary has been coated with the amine polymer and must be used in combination with the amine regenerator solution P/N 477433. 6 8 1 477433 34 2 eCAP™ Amine Capillary, 75 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) This capillary has been coated with the amine polymer and must be used in combination with the amine regenerator solution P/N 477433. 5 7 8 6 1 The eCAP Amine capillary improves resolution of basic drugs. (1)-Impurity, (2)-Doxepin, (3)-Nordoxepin, (4)-Imipramine, (5)-Desipramine, (6)-Amitriptyline, (7)-Nortriptyline, (8)-Protriptyline. Beckman Coulter Contents Index 17 CE SUPPLIES U N T R E AT E D F U S E D - S I L I C A C A P I L L A R I E S Beckman Coulter bare fused-silica capillaries are routinely used for a variety of CE separations. The pKa of fused silica is about 1.5. The degree of ionization of the walls of these capillaries is controlled by the pH of the buffers used for separation. FUSED-SILICA CAPILLARIES Pre-Burned Windows 20 µm I.D. × 375 µm O.D. 338475 20 cm effective length quantity 3 50 µm I.D. × 375 µm O.D. 75 µm I.D. × 375 µm O.D. 338451 50 cm effective length quantity 3 338454 50 cm effective length quantity 3 360801 111 cm total length to interface to EDA 20 cm to window quantity 3 360800 111 cm total length to interface to EDA 20 cm to window quantity 3 100 µm I.D. × 375 µm O.D. 149053 115 cm total length; 100 cm to window. Methods development capillary for CEMS/MS system. Without Pre-Burned Windows 360804 5 meters total length 338472 5 meters total length 338473 5 meters total length 338474 5 meters total length C E Q ™ 2 0 0 0 X L C A P I L L A R Y A R R AY S Each array has eight coated capillaries, complete with inlet electrode cannula and detector array fitting. Ready for easy installation into the CEQ™ 2000XL. Each capillary will last at least 100 runs depending on method used, enabling at least 800 separations to be performed before replacement. Storage temperature: 6°C. Beckman Coulter PART N UMBER D ESCRIPTION 608015 CEQ DNA Separation Array, 50–100 µm 50 cm in length, 100 µm I.D., 200 µm O.D. 608087 CEQ DNA Separation Array, 33–75 µm 33 cm in length, 75 µm I.D., 200 µm O.D. Contents Index 18 CE SUPPLIES P/ACE™ MDQ CARTRIDGES PART N UMBER AND ACCESSORIES D ESCRIPTION 144738 Blank Cartridge Assembly Kit Contains cartridge body, 100 × 800 µm aperture, tubing kit, nuts, ferrules, and O-rings. Compatible with aqueous buffer systems. 149044 Blank Cartridge – CE-MS/CEC Kit For use with CE-MS/MS or CEC applications where organic solvents are primarily used. Kit contains cartridge body, 100 × 800 µm aperture, tubing kit, nuts, ferrules, and O-rings. 144645 Cartridge Rebuilding Kit Contains capillary length template, cleaving stone, rebuild instructions, dual seals, single seals, clips, O-rings, installation tool, and tweezers. 970297 Cartridge Aperture O-Rings (quantity 2) 144689 Cartridge Tubing Kit Consists of 20-, 30-, 40-, and 50-cm lengths of heat-formed tubing and all connectors. 144717 Cartridge Tube Kit 100 Cartridge coolant tubing (100 cm total length). 144866 Cartridge Clip with Dual Seal (quantity 4 red seals) Capillary cartridge clip and dual seal is designed to seal the capillary junction between the bottom of the P/ACE MDQ cartridge and the interface block. Seal can be used for capillaries with outside diameters as small as 150 µm. 144873 Cartridge Clip with Single Seal (quantity 4 green seals) Cartridge clip with single seal is designed to seal the capillary junction around the optics window in the P/ACE MDQ cartridge. 144711 Aperture, 100 × 800 µm (kit of 3) Recommend replacement after 3 months of use. 144712 Aperture, 100 × 200 µm (kit of 3) Recommend replacement after 3 months of use. 144829 EDA Cartridge and Adapter Kit New external detector adapter cartridge with all tubing, clips, seals, etc., and the adapter couplings. Cartridge is detector bypass type. 144822 EDA Capillary Adapter Assembly External detector adapter body, adapter nuts, seals, fittings, and tubing kit. Used to make existing MDQ cartridges into EDA (utilizes the window). No cartridge included. 144834 EDA Tubing Kit Consists of precut EDA tubing, nuts, O-rings, and ferrules. Beckman Coulter Contents Index 19 CE SUPPLIES P/ACE™ 5000 CARTRIDGES & ACCESSORIES eCAP™ Cartridges With Capillaries for P/ACE 5000 Series Each capillary cartridge below contains a fused-silica capillary and is designed with a prealigned aperture for on-capillary detection. Circulation ports permit flow of inert heat transfer fluid to ensure efficient temperature control. Capillary lengths listed are effective lengths from inlet to detector. PART N UMBER D ESCRIPTION 727604 Capillary Cartridge Includes tested fused-silica capillary, 50 cm length, 50 µm I.D., 375 µm O.D., 100 × 200 µm aperture. Capillaries pretreated with 0.1 N NaOH; run with Test Mix, P/N 338425, and Run Buffer A, P/N 338426. The test mix electropherogram is included. 727605 Capillary Cartridge Includes tested fused-silica capillary, 50 cm length, 75 µm I.D., 375 µm O.D., 100 × 200 µm aperture. Capillaries pretreated with 0.1 N NaOH; run with Test Mix, P/N 338425, and Run Buffer A, P/N 338426. The test mix electropherogram is included. 727607 High-Sensitivity UV Cartridge Includes tested fused-silica capillary, 50 cm length, 50 µm I.D., 375 µm O.D., 100 × 800 µm aperture. Capillaries pretreated with 0.1 N NaOH; run with Test Mix, P/N 338425, and Run Buffer A, P/N 338426. The test mix electropherogram is included. 727606 High-Sensitivity UV Cartridge Includes tested fused-silica capillary, 50 cm length, 75 µm I.D., 375 µm O.D., 100 × 800 µm aperture. Capillaries pretreated with 0.1 N NaOH; run with Test Mix, P/N 338425, and Run Buffer A, P/N 338426. The test mix electropherogram is included. 360604 LIF Cartridge Includes tested fused-silica capillary, 50 cm in length, 75 µm I.D., 375 µm O.D. The Capillary Replacement Kit, P/N 338432, and capillary tubing should also be purchased in order to replace the capillary. The eCAP Capillary Cartridge can accommodate capillary tubing from 20 cm to 120 cm in length. Beckman Coulter Contents Index 20 CE SUPPLIES P/ACE™ 5000 CARTRIDGES & ACCESSORIES eCAP™ Blank Capillary Cartridges for P/ACE 5000 Series Insert a capillary into this cartridge to run on the P/ACE 5000 series. PART N UMBER D ESCRIPTION 727610 Blank High Sensitivity UV Cartridges 100 × 800 µm aperture 727608 Blank Capillary Cartridge 100 × 200 µm aperture 338449 Blank Capillary Cartridge 50 × 200 µm aperture 360692 LIF Cartridge Blank 338432 eCAP Capillary Replacement Kit Provides materials required to build your own cartridge (requires capillary tubing and blank capillary cartridge) or rebuild your existing capillary cartridge (requires capillary tubing). Includes necessary tools, detailed instructions, and materials for building/rebuilding 25 cartridges. Tools and materials include: capillary alignment plate, cleaving stone, clamps, gaskets, sealant strips, plugs, tools, and capillary retaining tubing. 338431 Consumable Kit Replacement supplies for the Capillary Replacement Kit. This kit includes gaskets, sealant strips, plugs, and capillary retainer tubing as required for building/rebuilding 25 cartridges. Beckman Coulter Contents Index 21 CE APPLICATION KITS s the chemistry is an important part of any application, Beckman Coulter has developed a wide variety of application kits. These kits increase productivity by speeding up the methods development process and ensuring consistent reagent performance. Each kit contains the capillaries, buffers, standards and instructions necessary for the analysis. The standard test protocols allow for rapid suitability testing of the capillary prior to the analysis of the chosen analyte. A METHODS DEVELOPMENT The P/ACE™ MDQ Methods Development Kit is designed to give a starting point for the development of a capillary zone electrophoresis analysis of complex proteins, pharmaceuticals or basic analytes. This kit includes both neutral (polyacrylamide-based) and amine coated capillaries. Benzyl alcohol is included as a neutral EOF marker while histamine is used as a reference marker for the neutral capillary. PART N UMBER D ESCRIPTION 501310 P/ACE MDQ Methods Development Kit Consists of an amine capillary, a neutral capillary, 20 mM citrate/ MES buffer, pH 6.0, 50 mM Tris buffer, pH 8.0, Small Molecule Test Mix, Protein Test Mix, histamine reference marker, neutral marker, amine regenerator solution, and care and use guide. Reorder Components 477441 477431 477433 477443 477427 Separation of Small Molecule Test Mix on a 50 cm Amine Capillary (50 µm I.D.) using 50 mM Tris Buffer, pH 8.0, at 25 kV, UV 254 nm, 3 second 0.5 psi pressure injection. Beckman Coulter eCAP™ Neutral Capillary 50 µm I.D., 45 cm total length (quantity 1) eCAP Amine Capillary 50 µm I.D., 65 cm total length (quantity 1) Amine Regenerator Solution Citrate/MES Buffer, pH 6.0 Tris Buffer, pH 8.0 477421 Small Molecule Test Mix (4.0 mL) Includes: N-acetylprocainamide, 250 µg/mL Procainamide, 350 µg/mL Nicotine 477436 Protein Test Mix Includes: Lysozyme, 1 mg Cytochrome C, 1 mg Ribonuclease A, 1 mg 477434 477446 Neutral Marker Histamine Reference Marker Contents Index 22 CE APPLICATION KITS C H I R A L A N A LY S I S Since the chemical properties of enantiomers are identical, typical measurements and separation techniques cannot be used to distinguish one from the other. The key to separating enantiomers is to first create diastereomers from the enantiomers. Diastereomers may be created through chemical derivatization with a “chiral” reagent, or they may be formed transiently through interactions with chiral selectors. The latter is usually the most desirable as it is the easiest to employ. Capillary electrophoresis has proven the most ideal analytical tool for this purpose, as it is simple to construct and modify a chiral environment within a capillary. The use of cyclodextrins for differential host-guest complexation of enantiomers is by far the most common chiral selector and is the basis of the chiral separation strategy that we propose. Beckman Coulter’s primary strategy focuses on the use of highly sulfated cyclodextrins (HSCDs) which are a family of three chiral reagents. This strategy first involves screening the compound for separation using all three (α, β, and γ) HSCDs and then optimizing on the reagent which yields the best resolution. This initial screen involves the use of a single method and has been successful in greater than 90% of the compounds that Beckman Coulter has analyzed. PRIMARY STRATEGY Primary Screen • 50 µm bare fused silica Capillary – 20 cm to Detector • • • • • Polarity – anode at detector Detection – 200 nm Buffer – 50 nM phosphate pH. 2.5 Selector – α, β and γ HSCD 15 kV constant voltage YES Use CD which gave best resolution and vary concentration Further optimize temperature column length, field strength Did you achieve Resolution? NO Did peak shape broaden YES NO Increase HSCD to 10% and try all 3 HSCD’s Decrease [HSCD} to 2% Resolution? YES NO Optimize Fine-tune HSCD concentration Temperature Resolution? NO YES Go to Secondary Strategy Go to Secondary Strategy Capillary Length Field Strength Beckman Coulter Contents Index 23 CE APPLICATION KITS C H I R A L A N A LY S I S ( C O N T I N U E D ) Highly Sulfated Cyclodextrins The HSCDs are a proprietary distribution of cyclodextrins with an average number of 12 sulfates for the β-CD, 11 for the α-CD and 13 for the γ-CD. These distributions were preferentially selected over single isomers to provide increased resolution under defined separation conditions. These products perform well for the analysis of many neutral, basic and weakly acidic compounds of pharmaceutical and biological interest. To ensure batch-to-batch consistency, Beckman Coulter has developed a process which generates the final product as a 20% w/v solution of the HSCDs. Our processes in combination with a very rigorous quality control program ensure consistent matching of all lots to a Gold standard. PART N UMBER D ESCRIPTION 149869 Highly Sulfated Cyclodextrin 20% w/v Trial Kit Consists of HS α Cyclodextrin (5 mL) 20% w/v, HS β Cyclodextrin (5 mL) 20% w/v, HS γ Cyclodextrin (5 mL) Test Mix, PTS Marker (1 mL @ 10 mMolar), Capillary Conditioning Solution and Phosphate Buffer, pH 2.5 (50 mL). 713348 713349 713331 713347 713350 713351 HS α Cyclodextrin (5 mL) 20% w/v HS α Cyclodextrin (100 mL) 20% w/v HS β Cyclodextrin (5 mL) 20% w/v HS β Cyclodextrin (100 mL) 20% w/v HS γ Cyclodextrin (5 mL) 20% w/v HS γ Cyclodextrin (100 mL) 20% w/v 713330 HS Cyclodextrin Test Mix Includes: • pseudoephedrine enantiomers • glutethimide enantiomers 713328 713333 477422 PTS Marker (1 mL @ 10 mMolar) Capillary Conditioning Solution (10 mL) Phosphate Buffer, pH 2.5 (50 mL) Clicking on the picture at the left will open A-1889A, "Methods Development Strategy for Enantiomer Analysis Using the P/ACE MDQ Chiral System" Example of amphetamine enantiomers separated with highly sulfated γ cyclodextrin. Beckman Coulter Contents Index 24 CE APPLICATION KITS C H I R A L A N A LY S I S ( C O N T I N U E D ) I f no resolution is obtained from the primary strategy, Beckman Coulter offers a secondary approach with the P/ACE MDQ Chiral Methods Development Kit. This kit utilizes a selection of four non-charged cyclodextrins. CHIRAL METHODS DEVELOPMENT SECONDARY STRATEGY Choose UV wavelength Choose CD type or try all 4 CDs Separate with: High pH Buffer Low and High [CD] Reversed Polarity Chiral Separation? ACID N BASE Solute: Acid or Base N Determine pK of solute Y Separate with: Low pH Buffer Low and High [CD] Normal Polarity Chiral Separation? Y Separate with: pH = pK Buffer Low and High [CS] Acids: Reversed Polarity Bases: Normal Polarity N Chiral Separation? Try other Chiral Selectors Y Optimize Determine pK of solute [CD]; E; T; pH PART N UMBER D ESCRIPTION 501300 P/ACE MDQ Chiral Methods Development Kit Consists of 2 neutral capillaries, high pH buffer, low pH buffer, adjustable pH buffer, β-cyclodextrin, γ-cyclodextrin, HP-β-cyclodextrin, and DM-β-cyclodextrin, Test Mix, Methods Development Guide, Chiral Methods Development Flow Chart, and Buffers Dilution Guide. Beckman Coulter Contents Index 25 CE APPLICATION KITS C H I R A L A N A LY S I S ( C O N T I N U E D ) Reorder Components PART N UMBER D ESCRIPTION 477441 eCAP™ Neutral Capillary 50 µm I.D., 45 cm total length Chiral Kit High pH Buffer (500 mL) Chiral Kit Low pH Buffer (500 mL) Chiral Kit Adjustable pH Buffer (500 mL) Chiral Kit Test Mix (1 mL) β-cyclodextrin (25 g) γ-cyclodextrin (25 g) Dimethyl-β-cyclodextrin (25 g) Hydroxypropyl-β-cyclodextrin (25 g) 477449 477448 477447 477469 477437 477438 477467 477470 A typical separation of the Chiral Kit Test Mix (DANS-DL-LEU), using the Chiral Kit High pH Buffer. Beckman Coulter Contents Index 26 CE APPLICATION KITS P R O T E I N A N A LY S I S Proteins make up one of the most analytically challenging group of compounds due to their complexity and charge heterogeneity. Yet CE has been an ideal analytical tool for this class of compounds. As there is no one single methodology that can cover all proteins, Beckman Coulter has put together a series of methods development kits to help you design CE methodology for protein analysis. These kits are developed as “getting started” chemistries and include 1) an isoelectric focusing kit which offers a general screen of a broad range of isoelectric points, 2) a kit to allow the separation of proteins by size using methodology analogous to SDS-PAGE, and 3) a capillary zone electrophoresis methods development kit, utilizing a neutral capillary coating to minimize protein interaction with the wall. PART N UMBER D ESCRIPTION 477490 eCAP™ cIEF 3-10 Screening Kit Isoelectric focusing (IEF) is commonly used in both research and industrial settings for purity assessment, identity, monitoring of degradation products, and microheterogeneity analysis. The eCAP cIEF 3-10 Kit provides an advanced alternative to slab gel isoelectric focusing. With the automated features of CE, loading, focusing, mobilizing and detecting proteins is simple. The ampholyte in this kit covers a wide range from pH 3.0 to 10.0. This will provide a good starting range to allow for screening for the pI in a single run. Resolution of proteins with as little as 0.05 pI unit differences are possible using the eCAP Neutral Capillary which minimizes EOF and provides sharp, focused zones. The eCAP cIEF 3-10 Screening Kit contains (2) eCAP Neutral coated capillaries, ampholytes (3-10), cIEF polymer solution, anolyte, catholyte, pI standards and instructions for system set up and analysis. 32 Karat™ software allows the construction of isoelectric point plots such that the pIs of unknowns can be calculated automatically. Reorder Components 477441 Protein standards: Ribonuclease A (pI 9.45), Carbonic Anhydrase II (pI 5.9), β-Lactoglobulin A (pI 5.1), CCK Flanking Peptide (pI 2.75). 477488 477497 477487 eCAP Neutral Capillary, 50 µm I.D., 45 cm total length, 14 cm from window to outlet (quantity 1) cIEF Ampholyte, 3-10 (quantity 1 mL) cIEF Polymer Solution (quantity 100 mL) cIEF Protein Standards Includes: Ribonuclease A (pI 9.45) (quantity 3.84 mg) Carbonic Anhydrase II (pI 5.9) (quantity 0.32 mg) β-Lactoglobulin A (pI 5.1) (quantity 0.64 mg) CCK Flanking Peptide (pI 2.75) (quantity 0.16 mg) A calibration curve from the standards included in the cIEF 3-10 kit. Constructed by plotting the pIs of these proteins against their migration time. Beckman Coulter Contents Index 27 CE APPLICATION KITS P R O T E I N A N A LY S I S ( C O N T I N U E D ) PART N UMBER D ESCRIPTION 477420 eCAP™ SDS 14-200 Kit One of the most common methods used to assess the molecular weights of proteins has been SDS-PAGE. Beckman Coulter has automated SDS molecular weight and purity determinations with the development of the eCAP SDS 14-200 Kit. With CE, proteins are detected directly using UV detection at 214 nm, resulting in accurate quantitation without the need for staining. Results are obtained in only 15 minutes, with no gel preparation. Samples are treated in the same manner as SDS-PAGE: heat denaturation in the presence of SDS and optional disulfide bond reduction with β-mercaptoethanol. The separation is by capillary gel electrophoresis using a formulation of polyethylene oxides optimized for the resolution of proteins from 14,000 to 200,000 daltons. A polyacrylamide coated neutral capillary is used to eliminate EOF and minimize sample interaction with the wall. This results in very reproducible separations with run-to-run, day-to-day migration time RSDs less than 1%. The capillary coating is robust, allowing acid washes between each run. The gel (buffer) is replaceable, allowing a “fresh start” with each sample. With glycoproteins, discrepancies in molecular weight can be minimized with the use of the Ferguson method. The gel buffer can be easily diluted and placed in the autosampler at several different concentrations, allowing the Ferguson analysis to be automated. Each kit contains a neutral capillary, buffers, test mix and markers to perform at least 200 runs. Reorder Components 241521 Separations of Interleukens 3 and 6 by SDS-MW analysis using eCAP SDS 14-200 Kit. 477416 477418 241524 241525 Beckman Coulter Contents eCAP Neutral Capillary (SDS), 100 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) SDS 14-200 Gel Buffer (quantity 55 mL) Protein Test Mix (quantity 3.4 mg total protein) α-Lactalbumin (14.2 kD) Carbonic Anhydrase (29 kD) Ovalbumin (45 kD) Bovine Serum Albumin (66 kD) Phosphorylase B (97.4 kD) β-Galactosidase (116 kD) Myosin (205 kD) Orange G Reference Marker (0.1% solution) (quantity 1 mL) Sample Buffer (0.12 M Tris-HCl, 1% SDS, pH 6.6) (quantity 50 mL) Index 28 CE APPLICATION KITS P R O T E I N A N A LY S I S ( C O N T I N U E D ) PART N UMBER D ESCRIPTION 477445 eCAP™ Neutral Capillary Methods Development Kit for Proteins The heterogeneous nature of proteins makes it almost impossible to design a single method that will work for all. With capillary zone electrophoresis, analytes are resolved due to differences in expressed charge relative to mass. A protein’s pI, its solubility state, presence of prosthetic groups or extent of glycosylation will all impact the choice of the appropriate buffer for the CZE analysis. Moreover, at neutral to basic pH, the surface of the capillary is highly charged and can act as an adsorptive surface for many proteins. The eCAP Neutral Capillary Methods Development Kit utilizes a capillary with a neutral polyacrylamide-bonded surface, rendering it nonreactive to most proteins. The kit also contains a series of buffers, test compounds, and markers to assist you in developing a method for the analysis of your protein. Reorder Components 477441 477442 477443 477444 477446 241524 477436 eCAP Neutral Capillary, 50 µm I.D., 45 cm total length, 14 cm from window to outlet (quantity 1) 50 mM Citrate Buffer, pH 3.0 (quantity 100 mL) 50 mM Citrate/MES Buffer, pH 6.0 (quantity 100 mL) 50 mM Tricine Buffer, pH 8.0 (quantity 100 mL) Histamine Reference Marker (cation) (quantity 1 mL) Orange G Reference Marker (anion) (quantity 1 mL) Protein Test Mix 1st and 120th run of acidic proteins using the eCAP Neutral Capillary Methods Development Kit. Beckman Coulter Contents Index 29 CE APPLICATION KITS C A R B O H Y D R AT E A N A LY S I S Carbohydrate analysis is essential to fully characterize a glycoprotein-based biopharmaceutical and is considered to be a challenging and formidable task. At first glance, CE does not appear to be ideal in that most carbohydrates lack readily ionizable functional groups and the ability to either absorb or fluoresce. This situation is easily remedied with a simple reductive amination reaction using 1-aminopyrene-3,6,8-trisulfonate (APTS). This reaction provides specificity, ample charge for mobility and strong fluorescence for detection with laser-induced fluorescence (LIF). APTS has been used successfully for the derivatization of both oligosaccharides and monosaccharides and coupled with CE-LIF provides more quantitative information with increased resolving power. PART N UMBER D ESCRIPTION 477600 eCAP™ Carbohydrate Labeling and Analysis Kit This chemistry includes the components necessary to label and separate oligosaccharides. The kit includes: NCHO coated capillary NCHO separation buffer Labeling reagents: - Quantitation control (maltose) - Labeling dye (APTS) - Labeling dye solvent (15% acetic acid) - Glucose ladder (standard) - APTS-M (monosaccharide-grade) -O3S NH2 501309 CE-Grade APTS Carbohydrate Labeling Reagent APTS is synthesized at Beckman Coulter as a highly purified reagent ideal for labeling the reducing terminus of carbohydrates. Its (-) 3 charge provides high mobility for very rapid analysis of carbohydrates by capillary zone electrophoresis. This reagent is suitable for labeling oligosaccharides. APTS Formula: Labeling: Excitation λ: Emission λ: Formula Wt: Qty: -O3S SO3APTS Beckman Coulter 1-aminopyrene-3,6,8-trisulfonate At reducing terminus by reductive amination 488 nm 520 nm (of labeled product) 523 synthesized as tri-sodium salt 2 × 5 mg 725898 Monosaccharide-Grade APTS Carbohydrate Labeling Reagent Purified APTS, lyophilized with citric acid. APTS Formula: Excitation λ: Emission λ: Formula Wt: Container: Vial Contents: Storage: Shelf Life: Contents C16H8NO9Na3S3 488 nm 520 nm 523.39 Amber glass vial, screw cap 20 mg APTS-M, 80 mg citric acid 2-8°C (light sensitive) 3 years from date of manufacture Index 30 CE APPLICATION KITS NUCLEIC ACIDS Agarose slab gel electrophoresis has long been used for the analysis of DNA and RNA. Although well established, it is time consuming, labor intensive and only semi-quantitative. Capillary gel electrophoresis offers an automated approach to nucleic acid analysis with on-line detection that is fully quantitative, extending the analytical capabilities of electrophoresis. Gels exist as polymers in solution, allowing the user an environment which can easily be optimized. Polymers in solution allow for an automated mechanism of gel loading and gel replacement. Beckman Coulter offers the following nucleic acid kits useful for the routine analysis of oligonucleotides, viral load determination, gene expression and the quantitative analysis of DNA-protein interactions through mobility-shift assays. CEQ™ 2000XL chemistries for DNA sequencing and fragment analysis are also described. PART N UMBER D ESCRIPTION 477480 eCAP™ ssDNA 100-R Kit The eCAP ssDNA Kit is designed for the analysis of oligonucleotides, providing a direct quantitative tool. This chemistry utilizes linear polyacrylamide in solution to form a sieving gel, which provides single base resolution of oligonucleotides between 10 and 100 bases. The neutral capillary provided with the kit has a stable, physically bonded polyacrylamide coating, which eliminates electroosmotic flow (EOF) and suppresses interactions of the sample with the capillary wall. This chemistry utilizes a standard Tris-Borate EDTA buffer including high concentrations of urea to prevent secondary structure formation. Applications of this kit have included DNA and RNA probes, ribozymes and anti-sense phosphorothioate oligonucleotides. This chemistry is compatible with both UV and LIF detection. 0.10 0.10 0.08 0.08 0.06 0.06 0.04 0.04 0.02 0.02 The kit includes coated capillaries (2), replaceable gel, and standards to perform at least 70 runs. Urea denaturant is included separately, enabling reconstitution to a native replaceable gel, if so desired. Reorder Components 477477 0.00 0.00 15 20 25 30 35 40 Analysis of 22-mer oligonucleotide; 300 V/cm and 30°C. Beckman Coulter 477621 45 338481 477626 Contents eCAP Neutral Capillary (DNA) 100 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) ssDNA 100-R Polyacrylamide Gel (lyophilized) (quantity 1 g) Buffer Kit, includes: Tris Borate EDTA Buffer (2) and Urea 7 M (2) ssDNA 100-R Test Mix, Poly d(A) 40-60 Mer Oligonucleotides (containing 20 fragments) (quantity 0.2 O.D. units) Index 31 CE APPLICATION KITS NUCLEIC ACIDS (CONTINUED) PART N UMBER D ESCRIPTION 477410 eCAP™ dsDNA 1000 Kit The eCAP dsDNA 1000 Kit is designed for the analysis of doublestranded DNA fragments from 72 to 1000 base pairs. This chemistry utilizes linear polyacrylamide in solution to form a sieving gel. A neutral capillary provided with this kit has a stable, physically bonded polyacrylamide coating which eliminates electroosmotic flow (EOF) and suppresses interactions of the sample with the capillary wall. This chemistry utilizes a standard Tris-Borate EDTA buffer and allows the addition of intercalating dyes like ethidium bromide or our proprietary EnhanCE™ to improve resolution and increase sensitivity. This kit is ideal for the analysis of PCR* products which can be analyzed directly with no sample clean-up. Applications of this kit have included gene expression analysis (competitive PCR), and genotyping experiments. The system is compatible with both UV and LIF detection, but LIF is recommended for most applications. Kit includes: (2) 100 µm I.D. neutral capillaries (DNA), (3) vials of replaceable polyacrylamide gel, (1) test mix consisting of HaeIII restriction digest φ174 DNA containing 11 fragments from 72 bp to 1,353 bp, and instructions and methods for system set-up and analysis. For LIF applications, we recommend the use of the intercalating dye EnhanCE. * PCR is covered by U.S. patents owned by Hoffmann-La Roche Inc. Reorder Components 477477 Separation of an Hae III restriction digest of φX174 DNA using LIF detection. Pressure injection for 10 seconds (10 µg/mL sample). 477628 477414 477406 eCAP Neutral Capillary (DNA) 100 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) dsDNA 1000 Polyacrylamide Gel Kit Lyophilized (quantity: package of 3) dsDNA 1000 Test Mix, HaeIII Restriction Digest φX174 DNA (quantity 20 µg) dsDNA 1000 Internal Standard Orange G Reference Marker (quantity 1 mL) Recommended 477409 EnhanCE Dye (quantity 0.5 mL) CE-LIF analysis of DNA products generated by competitive RNA-PCR of cytochrome P450-1A1 mRNA in dioxin-treated HepG2 cells. Target sequence is 367 bp; competitor is 228 bp; CF=carboxyfluorescein marker; IS=328 bp internal standard. Beckman Coulter Contents Index 32 CE APPLICATION KITS NUCLEIC ACIDS (CONTINUED) PART N UMBER D ESCRIPTION 477486 eCAP™ dsDNA 20,000 Kit The eCAP dsDNA 20,000 Kit is designed for the analysis of doublestranded DNA fragments from 1,000 to 20,000 base pairs. This chemistry utilizes linear polyacrylamide in solution to form a sieving gel. A neutral capillary provided with this kit has a stable, physically bonded polyacrylamide coating which eliminates electroosmotic flow (EOF) and suppresses interactions of the sample with the capillary wall. This chemistry utilizes a standard Tris-Borate EDTA buffer system and allows the addition of intercalating dyes like ethidium bromide or our proprietary EnhanCE™, to improve resolution and increase sensitivity. This kit is ideal for the analysis of large PCR* products which can be analyzed directly with no sample clean-up. The system is compatible with both UV and LIF detection. Kit includes: (2) 100 µm I.D. neutral capillaries (DNA), (3) vials of replaceable polyacrylamide gel, (1) test mix consisting of HindIII restriction digest of λ DNA. Contains 8 fragments from 125 bp to 23,130 bp. For LIF applications, we recommend the use of the intercalating dye EnhanCE. Reorder Components 477477 477485 477483 Before and after separation of DNA fragments derived from the complete EcoR1 digestion of a 12 Kbp plasmid vs. the undigested plasmid itself. 477406 eCAP Neutral Capillary (DNA) 100 µm I.D., 65 cm total length, 12 cm from window to outlet (quantity 1) dsDNA 20,000 Polyacrylamide Gel Kit (lyophilized) (quantity: package of 3) eCAP Test Mix, HindIII Digest 8 fragments from 125 to 23,130 base pairs (quantity 500 µl) dsDNA 1000 Internal Standard Orange G Reference Marker (quantity 1 mL) Recommended 477409 EnhanCE Dye (quantity 0.5 mL) * PCR is covered by U.S. patents owned by Hoffmann-La Roche Inc. Beckman Coulter Contents Index 33 CE APPLICATION KITS C E Q ™ 2 0 0 0 X L A P P L I C AT I O N K I T S PART N UMBER D ESCRIPTION 608000 CEQ™ DTCS Kit Dye-labeled dideoxy-terminator cycle sequencing kit for 96 reactions. Includes: thermostable DNA polymerase and pyrophosphatase; CEQ dye-labeled terminators (ddUTP, ddGTP, ddCTP, ddATP); dNTP mix solution; sequencing reaction buffer, pUC18 control template, M13(-47) sequencing primer, mineral oil and glycogen. Storage temperature: -20°C. 608120 CEQ DTCS – Quick Start Kit Dye terminator cycle sequencing (DTCS) reactions incorporate many components including DNA polymerase, pyrophosphatase buffer, dNTPs, dye terminators, DNA templates and primers. The CEQ DTCS Quick Start Kit simplifies this process by using a master-mix of many of the components—reducing the number of pipetting steps from 10 to 4 while using larger transfer volumes to reduce pipetting error. Each kit provides enough reagents to complete 100 sequencing reactions. 608010 CEQ LFR Gel I Special CEQ polyacrylamide denaturing gel assures high-resolution separations on the CEQ 2000XL. Used for both DNA sequencing and fragment analysis. Packaged in a cartridge for quick reloading by operator. The cartridge holds 11.5 mL of polyacrylamide gel, sufficient for 12 loads into capillary arrays (96 separations). Storage temperature: 6°C. 608012 CEQ Separation Buffer (quantity 4/pack) Each bottle has a twist top with a convenient dropper tip and contains sufficient buffer (30 mL) to fill one flat-bottomed 96-well CEQ 2000XL Buffer Plate. Storage temperature: 6°C. 608098 CEQ DNA Size Standard Kit– 400 DNA size standard for analysis of fragments up to 400 nucleotides.Sufficient for 96 fragment analysis separations. Includes DNA fragments of the following sizes labeled with CEQ WellRED fluorescent dye: 60, 70, 80, 90, 100, 120, 140, 160, 180, 190, 200, 220, 240, 260, 280, 300, 320, 340, 360, 380, 400, and 420 nucleotides. Storage temperature: -20°C. Includes mineral oil for overlay. 608095 CEQ DNA Size Standard Kit– 600 DNA size standard for analysis of fragments up to 600 nucleotides. Sufficient for 96 fragment analysis separations. Includes DNA fragments of the following sizes labeled with CEQ WellRED fluorescent dye: 60, 70, 80, 90, 100, 120, 140, 160, 180, 190, 200, 220, 240, 260, 280, 300, 320, 340, 360, 380, 400, 420, 440, 460, 480, 500, 520, 540, 560, 580, 600, 620, and 640 nucleotides. Storage temperature: -20°C. Includes mineral oil for overlay. 608105 CEQ Fragment Analysis Test Sample A set of fluorescently labeled DNA fragments of known sizes and defined spacing used to verify the resolution power of the CEQ 2000XL fragment analysis system. Sufficient for 24 tests. Storage temperature: -20°C. Beckman Coulter Contents Index 34 CE CHEMISTRY KITS BUFFERS, TEST MIXTURES, PART N UMBER AND REAGENTS D ESCRIPTION 338437 Capillary Performance Test Kit The Capillary Performance Test Kit is designed to test functionality of the CE system. The test mixture consists of low concentrations of three closely related compounds (benzoic acid, p-hydroxybenzoic acid and p-hydroxyphenylacetic acid—see structures). Analyzing this test mixture confirms system resolution and sensitivity performance. The kit contains Test Mixture A (20 mL), Run Buffer A (50 mL), and Regenerator Solution A (20 mL). One kit is included with each P/ACE™. 338425 Capillary Performance Test Mixture A Benzoic acid, p-hydroxybenzoic acid, p-hydroxyphenylacetic acid (quantity 20 mL). OHBA d:\ train\ cedata~1\ acids1, Channel A 0.016 0.014 BA 0.014 0.016 0.010 338424 Capillary Regenerator Solution A 0.1 N sodium hydroxide (quantity 50 mL). 0.012 PhenylAcet 0.012 338426 Capillary Performance Run Buffer A 100 mM sodium borate, pH 8.3 (quantity 50 mL). 0.010 A U 0.008 A 0.008 U 501333 Capillary Performance Test Mix B This test mix consists of two closely related compounds (P-OH benzoic acid and P-OH phenylacetic acid. Analyzing this test mixture confirms system resolution and sensitivity performance. 0.006 0.006 0.004 0.004 338436 Borate Buffer Kit Includes boric acid solution, 0.4 M, 50 mL sodium tetraborate solution, 0.1 M (quantity 50 mL). 0.002 0.002 338433 Boric Acid, 0.4 M (quantity 50 mL) 0.000 0.000 338434 Sodium Tetraborate, 0.1 M (quantity 50 mL) 3.0 3.5 4.0 4.5 5.0 5.5 Minutes p-OH Phenylacetic Acid Beckman Coulter p-OH Benzoic Acid Benzoic Acid Contents Index 35 CE CHEMISTRY KITS CE-GRADE BUFFERS Beckman Coulter offers an extensive line of buffers specifically formulated for use with CE systems. PART N UMBER D ESCRIPTION 477422 eCAP™ Phosphate Buffer 50.0 mM, pH 2.5, 100 mL This buffer is also contained in the following application kits: P/N 477430 eCAP Amine Capillary Methods Development Kit (Small Molecules) and P/N 477735 Amine Capillary Methods Development Kit (Proteins). 477423 eCAP Phosphate Buffer 50.0 mM, pH 7.0, 100 mL This buffer is also contained in the following applications kits: P/N 477430 eCAP Amine Capillary Methods Development Kit (Small Molecules) and P/N 477735 Amine Capillary Methods Development Kit (Proteins). 477425 eCAP Acetate Buffer 50.0 mM, pH 4.5, 100 mL This buffer is also contained in the following applications kits: P/N 477430 eCAP Amine Capillary Methods Development Kit (Small Molecules) and P/N 477735 Amine Capillary Methods Development Kit (Proteins). 477426 eCAP MES Buffer 50.0 mM, pH 6.0, 100 mL This buffer is also contained in the following applications kits: P/N 477430 eCAP Amine Capillary Methods Development Kit (Small Molecules) and P/N 477735 Amine Capillary Methods Development Kit (Proteins). 477427 eCAP Tris Buffer 50.0 mM, pH 8.0, 100 mL This buffer is also contained in the following applications kits: P/N 501310 P/ACE™ MDQ Methods Development Kit, P/N 477430 eCAP Amine Capillary Methods Development Kit (Small Molecules) and P/N 477735 Amine Capillary Methods Development Kit (Proteins). 477442 eCAP Citrate Buffer 20.0 mM, pH 3.0, 100 mL This buffer is also contained in the following applications kit: P/N 477445 eCAP Neutral Capillary Methods Development Kit (Proteins). Beckman Coulter Contents Index 36 CE CHEMISTRY KITS CE-GRADE BUFFERS (CONTINUED) PART N UMBER D ESCRIPTION 477443 eCAP™ Citrate/MES Buffer (Citrate, 20.0 mM; MES, 20.0 mM/L) pH 6.0, 100 mL This buffer is also contained in the following applications kits: P/N 501310 P/ACE™ MDQ Methods Development Kit and P/N 477445 eCAP Neutral Capillary Methods Development Kit (Proteins). 477444 eCAP Tricine Buffer (20.0 mM) pH 8.0, 100 mL This buffer is also contained in the following applications kit: P/N 477445 eCAP Neutral Capillary Methods Development Kit (Proteins). 477447 eCAP Chiral Kit Adjustable pH Buffer (Acetate Buffer, 50.0 mM; Phosphate Buffer, 50.0 mM/L) pH 2.5, 500 mL This buffer is also contained in the following applications kit: P/N 501300 P/ACE MDQ Chiral Methods Development Kit. 477448 eCAP Chiral Kit Low pH Buffer (Phosphate Buffer, 50.0 mM) pH 2.5, 500 mL This buffer is also contained in the following applications kit: P/N 501300 P/ACE MDQ Chiral Methods Development Kit. 477449 eCAP Chiral Kit High pH Buffer (Phosphate Buffer, 50.0 mM) pH 8.0, 500 mL This buffer is also contained in the following applications kit: P/N 501300 P/ACE MDQ Chiral Methods Development Kit. Beckman Coulter Contents Index 37 LABWARE P/ACE™ MDQ LABWARE PART N UMBER D ESCRIPTION 970657 Vials, 2 mL (quantity of 100) 144648 Vial Caps, 2 mL (quantity 100 red) 970668 Vials, 0.5 mL (quantity 50) 144649 Vial Caps, 0.5 mL (quantity 50 blue) 144709 PCR* Vials (quantity 50) 358821 Micro Vial Springs Required for use of Micro Vials (quantity 10). 144656 PCR* Vial Caps (quantity 50 gray) 144657 Vial Holders Required for use of Micro Vials (quantity 50). 373660 96-Well Plates, Nonsterile, Without Lids Capacity: 300 µL/well (quantity 100). 144390 Buffer Tray 36 (2 mL vials) To be used with 36 × 2 mL vial and/or vial holders. 144543 Sample Tray 48 (2 mL vials) To be used with 48 × 2 mL vial and/or vial holders 144544 Sample Tray 48 (0.5 mL vials) To be used with 48 × 0.5 mL vials (does not require vial holders). 144824 Large-Volume Buffer Reservoir Consists of two buffer reservoir trays, 2 buffer reservoir lids, and lid removal tool. 144826 Buffer Reservoir Replacement Lid 144858 Replacement Buffer Lid Removal Tool 144865 Buffer Reservoir Replacement O-Rings (quantity 3) P/ACE MDQ Miscellaneous Supplies 144647 Coolant Filling Kit Consists of syringe, coolant fill tool, and connecting tubing. 359976 Liquid Coolant (450 mL, quantity 1) * PCR is covered by U.S. patents owned by Hoffmann-La Roche Inc. Beckman Coulter Contents Index 38 LABWARE LABWARE SUPPLIES P/ACE™ 2000–5000 SERIES FOR The Autosampler of the P/ACE 2000-5000 series accommodates up to 34 vials: 10 in the inner tray (for electrolytes) and 24 in the outer tray (for samples, conditioning fluids, and electrolytes). Each vial fits into a vial holder, then into the autosampler. Custom-made vial caps prevent evaporation of buffers and samples during operation. For oligonucleotide work, Mini Vials fit into the P/ACE 4 mL vials using the Mini Vial Springs. For microvolume work, Micro Vials fit into the 4 mL vials using the Micro Vial Springs. The countertop vial storage rack holds up to 40 vials in holders and 20 Micro Vials. PART N UMBER D ESCRIPTION 358807 Glass Vials 4 mL working volume for sample and electrolyte (quantity 100). 358818 Vial Holders Two pieces fit into P/ACE autosampler to hold sample and electrolyte vials (quantity 10). 359079 Vial Caps (gray silicone) Seals vials during run (quantity 50). 360004 Vial Caps For sample storage (quantity 10). 338487 Mini Vials For oligonucleotide work, polypropylene, 200-400 µL working volume (quantity 100). 338488 Mini Vial Springs Required for use of Mini Vials (quantity 50). 358819 Micro Vials For microvolume work, polyolefin, 5-30 µL working volume (quantity 10). 358821 Micro Vial Springs Required for use of Micro Vials (quantity 10). 359093 Vial Storage Rack Holds 40 vials and 20 Micro Vials in holders (quantity 1). 359980 Micro Vial Autosampler Kit Provided with each purchase of a P/ACE 5000. Includes 100 Vials, 10 Micro Vials, 10 Micro Vial Springs, 40 Vial Holders, Vial Storage Rack, and 50 Vial Caps. Beckman Coulter Contents Index 39 CE SUPPLIES AND LABWARE T E M P E R AT U R E - C O N T R O L L E D S A M P L E T R AY S U P P L I E S PART N UMBER D ESCRIPTION 727012 Vial Holder for Cooling Tray (package of 5) 727011 Ambient Vial Holder for Tray (package of 10) 727013 Polypropylene Vials, 200 µL (package of 100) MISCELLANEOUS SUPPLIES FOR P/ACE™ 2000-5000 PART N UMBER D ESCRIPTION 359976 Coolant 450 mL (quantity 1) 961142 Regulator for Nitrogen Tank 0-100 psi regulated output pressure (quantity 1). 927781 Beckman Coulter Contents Nitrogen Tank Quick Connector (quantity 1) Index 40 CE SUPPLIES AND LABWARE CEQ™ 2000XL LABWARE PART N UMBER D ESCRIPTION 609801 Sample Microtiter Plates (25/pack) Package of 25 V-bottom thermocycler-compatible polypropylene plates with 200 µL nominal volume to easily contain 40 µL of sample. Recommended for use as the CEQ 2000XL Sample Plate. 607445 Wetting Tray Plastic wetting tray serves as a docking station for the capillary inlet tips when not in use. One is included with the CEQ 2000XL DNA Analysis System. 609844 Buffer Microtiter Plates (100/pack) Four packages of 25 each flat-bottom polystyrene plates, nonsterile, without lids. Recommended for use as the CEQ 2000XL Separation Buffer Plate. 974705 Gel Waste Bottle (12/pack) Used for automatic collection of purged gel after separations on the CEQ 2000XL. Each bottle will hold 250 mL of waste gel, which is equivalent to approximately 50 plates of 96 runs each. 607533 Evaporation Control Mat (1/pack) 607530 Buffer Evaporation Cover Assembly (1/pack) The buffer evaporation cover is used to control evaporation of buffer during operation. One mat is included with the buffer evaporation cover assembly. One cover assembly is included with the CEQ 2000XL DNA Analysis System. Beckman Coulter Contents Index 41 CUSTOMER SUPPORT C O M P R E H E N S I V E VA L I DAT I O N PROGRAM With a quality management system registered to the ISO 9001 standard, Beckman Coulter utilizes a qualified development process. The P/ACE™ series CE systems have been developed under this process to comply with all CE, UL, and CUL mark requirements. The Software Validation Pack provides basic information regarding development and performance testing for the system software and can be utilized to support customer validation programs. A trained field service engineer performs instrument installation following a prescribed installation operation qualification protocol. In addition to installation, installation qualification includes conformity and delivery, basic training, and instrument performance testing. Optional operation qualification programs provide convenient processes that ensure that the instrument is performing to published specifications using calibrated testing equipment traceable to national standards. PART N UMBER D ESCRIPTION 144867 P/ACE MDQ and P/ACE 5000 Installation Qualification (IQ): For original start-up of new system. Includes instrument unpacking, set-up, start-up installation environment. No charge with system purchase. 144869 P/ACE MDQ OQ1 721110 P/ACE 5000 OQ1 Operation Qualification 1 (OQ1): Basic customer training and review of tutorial guide, performance verification, noise and drift tests, and documentation. No charge with system purchase. 144870 P/ACE MDQ OQ2 721111 P/ACE 5000 OQ2 Operation Qualification 2 (OQ2): For on-going operation qualification of a system. Performance verification, noise and drift tests, preventative maintenance service and parts, software verification test and report, documentation, preventative maintenance checklist, service report and instrument decal. OQ2 can be purchased as either an option to an existing service agreement or as a reimbursable service. 144688 P/ACE MDQ OQ3 726140 P/ACE 5000 OQ3 Operation Qualification 3 (OQ3): Comprehensive, full featured operation qualification support. Can be performed at installation or as an option to a service agreement. Includes preventative maintenance service and parts, software verification test and report, comprehensive function test of components, NIST standard traceability, documentation of engineer’s qualification, test equipment calibration, NIST standards, service report decal and preventative maintenance checklist. Beckman Coulter Contents Index 42 CUSTOMER SUPPORT Software Validation The Software Validation Pack includes a description of intended use, product history, technical description, algorithms, product documentation, options, development environment, support policies and notices. Beckman Coulter PART N UMBER D ESCRIPTION 149989 32 Karat™ Software Validation 144638 P/ACE™ MDQ Software Validation 726124 Software Validation for Gold™ Software Versions 8.1 and 8.2 Contents Index 43 CAPILLARY ELECTROPHORESIS EDUCATIONAL AIDS PART N UMBER D ESCRIPTION P/ACE™ MDQ Information CD-8296A Glycoprotein Analysis CD* CD-8297A Nucleic Acid Analysis CD* CD-8571A Chiral Analysis CD* BR-8177B P/ACE MDQ Brochure D-8239B CE Expert DS-8284A Laser-Induced Fluorescence Detector Data Sheet T-1823A Comparison of Air and Liquid Cooling in Capillary Electrophoresis T-1839A Translating Methodologies from P/ACE 2000 and 5000 to P/ACE MDQ T-1841A Application of the Caesar Algorithm to Capillary Electrophoresis T-1860A Precision in Capillary Electrophoresis * Ordering information available at http://www.beckmancoulter.com Primers Beckman Coulter 360643 Introduction to Capillary Electrophoresis (Volume I) 266924 Micellar Electrokinetic Chromatography (Volume III) 727484 Separation of Proteins and Peptides by Capillary Electrophoresis: Applications to Analytical Biotechnology (Volume V) 538703 Quantitative Applications of Capillary Electrophoresis in Pharmaceutical Analysis (Volume VI) 607397 Separation of DNA by Capillary Electrophoresis (Volume VII) 725036 High Performance Capillary Electrophoresis of Carbohydrates (Volume VIII) AP-8508A Capillary Electrochromatography Contents Index 44 CAPILLARY ELECTROPHORESIS EDUCATIONAL AIDS PART N UMBER D ESCRIPTION Newsletters Beckman Coulter NL-8412A P/ACE Setter. “Inaugural Edition.” Vol. 1, Issue 1, Summer 1997 NL-8413A P/ACE Setter. “Zen and the Art of the Capillary Tube.” Vol. 1, Issue 2, Fall 1997 NL_8415A P/ACE Setter. “Advances in the Quantification of HIV-1 Viral Load.” Vol. 2, Issue 1, Winter 1998 NL_8416A P/ACE Setter. “CE in Biotechnology: Providing Solution-Based Assays for Well-Specified Biologics.” Vol. 2, Issue 2, Spring 1998 NL-8417A P/ACE Setter. “CE in Genetic Analysis: Is it a Natural Progression ... or a New Frontier?” Vol. 2, Issue 3, Summer 1998 B98-5182 P/ACE Setter. “Advancements in Forensic Toxicology: CZE Replaces GC/NPD as the Screen of Choice for Basic Drugs.” Vol. 2, Issue 4, Fall 1998 B98-3134 P/ACE Setter. “Using cIEF to Characterize Recombinant Human Monoclonal Antibodies.” Vol. 3, Issue 1, April 1999 NL-8320A P/ACE Setter. “Detecting the Presence of Abnormal Prion Protein from Blood: Clearing a Major Analytical Hurdle.” Vol. 3, Issue 2, June 1999 NL-8408A P/ACE Setter. “Using Binding Isotherms to Accelerate CE Methods Development.” Vol. 3, Issue 3, September 1999 NL_8516A P/ACE Setter. “CE-SSCP Screening for BRCA1 and BRCA2—Allelic Mutations Associated With Breast Cancer.” Vol. 3, Issue 4, December 1999 NL-8597A P/ACE Setter. “Advancing Atherogenesis Research: High-Resolution Analysis of Oxidized Low-Density Lipoproteins.” Vol. 4, Issue 1, June 2000 NL-8721A P/ACE Setter. “Assessing the Homogeneity of Plasmid DNA: An Important Step Toward Gene Therapy.” Vol. 4, Issue 2, October 2000 NL-8756A P/ACE Setter. “Rapid Analysis of Single-Stranded STR Multiplexes Using P/ACE™ MDQ With Dual-Channel LIF Detection.” Vol. 4, Issue 3, December 2000 NL-8866A P/ACE Setter. “Applying Enantioselective CE in the Pharmaceutical Industry.” Vol. 5, Issue 1, April 2001 Contents Index 45 TECHNICAL & APPLICATION INFORMATION PART N UMBER D ESCRIPTION DNA Applications A-1726A High-Sensitivity Analysis of Nucleotides Using Electrokinetic Injection and Sample Stacking with MECC A-1748A Capillary Electrophoresis of dsDNA Fragments with UV and Laser-Induced Fluorescence Detection A-1774A Quantitative Capillary Electrophoretic Analysis of PCR* Products Using LIF A-1788A Competitive RNA-PCR by CE and LIF Detection for Quantitation of Cellular mRNA A-1872A Improved Sequencing of Plasmids on the CEQ 2000 by a Simple Template Preheating Procedure A-1876A Highly Precise DNA Sizing on the CEQ™ 2000 Fragment Analysis System A-1879A Analysis of 26 Weber Panel Simple Tandem Repeat Polymorphisms Using the CEQ 2000 Fragment Analysis System A-1892B Detecting Heterozygotes with the CEQ 2000XL DS-738A Analysis of Nucleic Acid Derivatives and Analogs by P/ACE™ R-8034 Multi-Target PCR Analysis by CE and LaserInduced Fluorescence. Nature, March 17, 1994 T-1853A Automation of Plasmid Purification with the Biomek® 2000 and QIAGEN’s “QIAprep 96 Turbo BioRobot” Kit for DNA Sequence Analysis on the CEQ 2000 DNA Analysis System T-1878A Allele Size and Plus A in CEQ Fragment Analysis Software * PCR is covered by U.S. patents owned by Hoffmann-La Roche Inc. Beckman Coulter Contents Index 46 TECHNICAL & APPLICATION INFORMATION PART N UMBER D ESCRIPTION Pharmaceutical Applications A-1746 Use of High-Low CE for Improved Quantitative Determination of Drug-Related Impurities A-1747 Quantitative Determination of Salbutamol-Related Impurities by CE with P/ACE 2000 A-1754 Enantiomeric Analysis of Primary and Secondary Amines A-1859A Advancements in Forensic Toxicology: CZE Replaces GC/NPD as the Screen of Choice for Basic Drugs A-1889A Methods Development Strategy for Enantiomer Analysis Using the P/ACE MDQ Chiral System DS-766 Separation of Antibiotics & Corticosteroids by MECC DS-821 Analysis of Flavonoids by Micellar Electrokinetic Chromatography with P/ACE System 2000 CD-8577A Reflections on Chirality Tutorial* * Ordering information available at http://www.beckmancoulter.com Protein Applications A-1736 CE as a Micropreparative Method A-1740 Analysis of Proteins by Capillary Zone Electrophoresis A-1744 The Analysis of a Recombinant Granulocyte Macrophage Colony Stimulating Factor A-1745B Resolution of Glycoforms of Ribonuclease B by P/ACE™ A-1750 Capillary Isoelectric Focusing Using Pressure/Voltage Mobilization A-1757 Monitoring Disulfide Bond Formation with P/ACE Capillary Electrophoresis A-1761 Separation of Recombinant Protein Glycoforms by Micellar Electrokinetic Capillary Chromatography A-1763 Analysis of a Monoclonal Antibody-Cytotoxin Conjugate by P/ACE Capillary Electrophoresis with Laser-Induced Fluorescence Detection continued on next page Beckman Coulter Contents Index 47 TECHNICAL & APPLICATION INFORMATION PART N UMBER D ESCRIPTION Protein Applications (continued) Beckman Coulter A-1769 Qualitative and Quantitative Analysis of Monoclonal Antibodies by One-Step Capillary Isoelectric Focusing A-1771A Hemoglobin Analysis by Capillary Isoelectric Focusing A-1772 Quantitative Capillary Electrophoresis of Monoclonal Antibodies Using the Neutral Capillary and SDS 14-200 Method Development Kits A-1777A Characterization of Proteases by CE with LaserInduced Fluorescence Detection A-1778A Digoxin Immunoassay Using CE with LIF Detection A-1791A Quantitation of Bioactive Peptides in Serum by CE with LIF Immunodetection (CE-LIF-ID) A-1861A Using cIEF to Characterize Recombinant Human Monoclonal Antibodies A-1870A Detecting the Presence of Abnormal Prion Protein from Blood: Clearing a Major Analytical Hurdle DS-774B Peptide Mapping with Capillary Electrophoresis DS-824 High-Sensitivity Peptide Mapping with Capillary Electrophoresis Using Laser-Induced Fluorescence Detection on a P/ACE System DS-833 Globin Separation with P/ACE CE R-8163A High-Resolution Carbohydrate Profiling by Capillary Gel Electrophoresis, Nature, Vol. 380, 4/4/96, 461-462 R-8165A Analysis of Mono-and Oligosaccharide Isomers Derivatized with 9-Aminopyrene-1, 4, 6-trisulfonate by C.E. with Laser-Induced Fluorescence, Analytical Biochemistry 230, 273-280 (1995) R-8166A Characterization of 9-Aminopyrene-1, 4, 6-trisulfonate-Derivatized Sugars by Capillary Electrophoresis with Laser-Induced Fluorescence Detection. Analytical Chemistry, 1995, Vol. 67, #13, 2239-2245 Contents Index 48 TECHNICAL & APPLICATION INFORMATION PART N UMBER D ESCRIPTION General Technical/Application Information Bulletins R95-2890 Comparison of Air and Liquid Cooling in Capillary Electrophoresis (U.S. only) T-1842A Mobility Determination in Capillary Electrophoresis Article Reprints Beckman Coulter AR-8571 Putting CE to Work — LC*GC R-8035A Determination of Salbutamol-Related Impurities by Capillary Electrophoresis—Journal of Chromatography, Dec. 1992 Contents Index 49 INDEX Numerics 32 Karat Workstation for P/ACE MDQ.........................................14 32 Karat Workstation Migration Upgrade .....................................14 A Accessory Pack (for PC)................................................................14 Application Kits.............................................................................22 APTS Carbohydrate Labeling Reagent ...................................30 CEQ DTCS Kit........................................................................34 CEQ DNA Size Standard Kits ................................................34 CEQ DTCS Quick Start Kit ....................................................34 Chiral Highly Sulfated Cyclodextrins .....................................24 Chiral Methods Development Kit ...........................................25 eCAP Carbohydrate Labeling and Analysis Kit .....................30 eCAP cIEF 3-10 Screening Kit ...............................................27 eCAP SDS 14-200 Kit ............................................................28 eCAP Neutral Capillary Methods Development Kit...............29 eCAP ssDNA 100-R Kit..........................................................31 eCAP dsDNA 1000 Kit ...........................................................32 eCAP dsDNA 20,000 Kit ........................................................33 MDQ Chiral methods Development Kit .................................25 MDQ Methods Development Kit ............................................22 Article Reprints..............................................................................49 B Buffers and Reagents .....................................................................35 Borate Buffer Kit.....................................................................35 Boric Acid................................................................................35 Capillary Performance Run Buffer A/B ..................................35 Capillary Regeneration Solution .............................................35 CEQ LFR Gel I .......................................................................34 CEQ Separation Buffer ...........................................................34 eCAP Acetate Buffer ...............................................................36 eCAP Chiral Kit Adjustable pH Buffer...................................37 eCAP Chiral Kit High pH Buffer............................................37 eCAP Chiral Kit Low pH Buffer ............................................37 eCAP Citrate Buffer ................................................................36 eCAP Citrate/MES Buffer.......................................................37 eCAP MES Buffer...................................................................36 eCAP Phosphate Buffer...........................................................36 eCAP Tricine Buffer................................................................37 eCAP Tris Buffer.....................................................................36 Sodium Tetraborate .................................................................35 C D Detector Accessories......................................................................12 488 nm Notch Filter (P/ACE MDQ) .......................................12 520 nm Bandpass Filter (P/ACE MDQ) .................................12 663 nm Bandpass Filter (P/ACE MDQ) .................................12 Detector Replacement Parts...........................................................19 EDA Cartridge Adapter Kit.....................................................19 MDQ EDA Capillary Adapter Assembly ................................19 MDQ EDA Tubing Kit ............................................................19 Detectors ........................................................................................11 MDQ DAD ..............................................................................11 MDQ Dual λ LIF.....................................................................11 MDQ External Detector Adapter Accessory Kit.....................11 MDQ Single λ LIF ..................................................................11 MDQ UV/Vis ..........................................................................11 E Educational Aids for CE ................................................................44 F Calibration......................................................................................13 635 LIF Calibration/Test Standard..........................................13 Capillary Arrays (CEQ 2000XL)...................................................18 CEQ DNA Separation Arrays..................................................18 Capillaries ......................................................................................15 eCAP Amine Capillary (50 µm)..............................................17 eCAP Amine Capillary (75 µm)..............................................17 eCAP N-CHO Capillary..........................................................15 eCAP Neutral Capillary ..........................................................15 eCAP Neutral Capillary (SDS-MW).......................................16 eCAP Neutral Capillary DNA.................................................16 Fused-Silica .............................................................................18 Beckman Coulter Untreated Fused-Silica ............................................................18 Capillary Electrophoresis (Description) ..........................................4 Carbohydrate Analysis...................................................................30 Cartridges.......................................................................................19 Blank High Sensitivity UV Cartridges....................................21 eCAP Blank Capillary Cartridges ...........................................21 eCAP Capillary Replacement Kit ...........................................21 LIF Cartridge Blank ................................................................21 MDQ Aperture 100 × 200 .......................................................19 MDQ Aperture 100 × 800 .......................................................19 MDQ Blank Cartridge Assembly Kit......................................19 MDQ Blank Cartridge CE-MS/CEC Kit ................................19 MDQ Cartridge Aperture O-Rings..........................................19 MDQ Cartridge Rebuilding Kit...............................................19 MDQ Cartridge Tubing Kit .....................................................19 MDQ EDA Cartridge Assembly..............................................19 MDQ EDA Cartridge Body.....................................................19 MDQ EDA Tubing Kit ............................................................19 P/ACE Capillary Cartridge......................................................20 P/ACE High Sensitivity UV Cartridge....................................20 P/ACE LIF Cartridge...............................................................20 Cartridge Clips...............................................................................19 MDQ Dual Seal (RED Seals)..................................................19 MDQ Single Seal (GREEN Seals)..........................................19 Coolant ....................................................................................38, 40 Contents Fiber Optic Cables .........................................................................13 LIF Fiber Optic Cable .............................................................13 LIF Fiber Optic Cable for Laser with SMA 905 Connector...13 MDQ DAD Fiber Optic Cable ................................................13 MDQ UV/Vis Fiber Optic Cable.............................................13 Replacement UV/Vis Fiber Optic Cable for P/ACE MDQ ....13 Replacement DAD Fiber Optic Cable for P/ACE MDQ ........13 Filters .............................................................................................12 UV Filters ................................................................................12 LIF 488 nm Notch Filter .........................................................12 LIF Emission Band Pass Filters ..............................................12 LIF Detector Filter Holder ......................................................12 50 INDEX H Highly Sulfated Cyclodextrins.......................................................24 History ..........................................................................................2-3 K Kits—see Application Kits L Labware..........................................................................................38 96-Well Plates.........................................................................38 Ambient Vial Holder for Temperature-Controlled Tray) ........40 Buffer Reservoir Lid Removal Tool........................................38 Buffer Reservoir Replacement Lid..........................................38 Buffer Reservoir Replacement O-Rings..................................38 Large-Volume Buffer Reservoir ..............................................38 MDQ 36 Position Buffer Tray (2 mL Vial).............................38 MDQ Sample Tray 48 .............................................................38 Micro Vial Autosampler Kit ....................................................39 Mini and Micro Vials, Springs, Caps (P/ACE 2000-5000).....39 Polypropylene Vials for Temperature-Controlled Tray ...........40 Vials, Caps, Holders, Springs (MDQ).....................................38 Vials, Caps, Holders, Springs (P/ACE 2000-5000) ................39 Vial Holder (Temperature-Controlled Sample Tray)...............40 Vial Storage Rack (P/ACE 2000-5000)...................................39 Lamps.............................................................................................13 MDQ Deuterium Lamp Assembly ..........................................13 P/ACE 2000 Deuterium Lamp Assembly ...............................13 P/ACE 5000 Deuterium Lamp Assembly ...............................13 Laser Modules................................................................................11 488 nm Argon-Ion Laser .........................................................11 635 nm Diode Laser ................................................................11 M Modules for P/ACE MDQ .............................................................10 N Newsletters (P/ACE Setter)............................................................45 Nitrogen Tank Regulator................................................................40 Nitrogen Tank Quick Connector....................................................40 Nucleic Acids Application Kits .....................................................31 P P/ACE Systems ...............................................................................6 MDQ Carbohydrate ...................................................................9 MDQ Chiral...............................................................................6 MDQ DAD Temperature Control..............................................9 MDQ DNA ................................................................................8 MDQ Glycoprotein....................................................................7 MDQ-LCQ CE-MS/MS ............................................................7 MDQ Methods Development ................................................... 6 MDQ Molecular Characterization................................................8 MDQ Quality Control .............................................................. 6 MDQ UV/Vis Ambient ............................................................ 9 MDQ UV/Vis Temperature Control......................................... 9 P/ACE 5000...............................................................................9 P/ACE 5010 UV/Vis Temperature Control ............................. 9 P/ACE 5500 DAD Ambient ..................................................... 9 Beckman Coulter Contents P/ACE 5510 DAD Temperature Control.................................. 9 P/ACE Education Package ....................................................... 8 Primers ...........................................................................................45 I: Introduction to Capillary Electrophoresis............................45 III: Micellar Electrokinetic Chromatography..........................45 VII: Separation of DNA by Capillary Electrophoresis ...........45 V: Separation of Proteins and Peptides by Capillary Electrophoresis: Applications to Analytical Biotechnology ...45 VI: Quantitative Applications of Capillary Electrophoresis in Pharmaceutical Analysis ....................................................45 VIII: High Performance Capillary Electrophoresis of Carbohydrates .....................................................................45 Capillary Electrochromatography ...........................................45 Protein Analysis .............................................................................27 R Reagents—see Buffers and Reagents S Sample Tray ...................................................................................34 MDQ 48 Position (0.5 mL Vials) ............................................34 MDQ 48 Position (2 mL Vials) ...............................................34 Software .........................................................................................14 32 Karat Software Reprocessing Key.....................................14 32 Karat Software (User Installed) .........................................14 32 Karat Software Migration Upgrade (User Installed) .........14 Standards........................................................................................27 cIEF Protein Standards Kit .....................................................27 T Technical and Application Information .........................................46 DNA Applications ...................................................................46 General Technical/Application Information Bulletins ............49 P/ACE MDQ Applications ......................................................44 Pharmaceutical Applications ...................................................47 Protein Applications ................................................................47 Test Mixtures .................................................................................13 Capillary Performance Test Mix A/B......................................35 HS Cyclodextrin Test Mid.......................................................24 LIF Test Mix (Sodium Fluorescein)........................................13 Protein Test Mix (P/ACE MDQ).......................................22, 28 Small Molecule Test Mix ........................................................22 ssDNA 100-R Test Mix ...........................................................31 V Validation Programs.......................................................................42 32 Karat Software Validation Pack ...................................14, 42 Gold Software Validation (Version 8.1 and 8.2) .....................43 MDQ and P/ACE 5000 Instrument Qualification (IQ) ....................................................................42 MDQ and P/ACE 5000 Operation Qualification 1 (OQ1) .............................................................42 MDQ and P/ACE 5000 Operation Qualification 2 (OQ2) .............................................................42 MDQ and P/ACE 5000 Operation Qualification 3 (OQ3) ............................................42 MDQ Software Validation .......................................................43 P/ACE Station Validation ........................................................43 51 All trademarks are the property of their respective owners. All specifications subject to change without notice. Developing innovative solutions in genetic analysis, drug discovery, and instrument systems. Beckman Coulter, Inc. • 4300 N. Harbor Boulevard, Box 3100 • Fullerton, California 92834-3100 Sales: 1-800-742-2345 • Service: 1-800-551-1150 • Telex: 678413 • Fax: 1-800-643-4366 • www.beckmancoulter.com Worldwide Bioresearch Division Offices: Australia (61) 2 9844-6000 Canada (905) 819-1234 China (86) 10 6515 6028 Eastern Europe, Middle East, Africa (41) 22 994 07 07 France 01 49 90 90 00 Germany (89) 35870-0 Hong Kong (852) 2814 7431 / 2814 0481 Italy 02-953921 Japan 03-5404-8359 Mexico 525-559-16-35 Netherlands 0297-230630 Singapore (65) 339 3633 South Africa (27) 11-805-2014/5 Spain (34) 91 3836080 Sweden 08-564 85 900 Switzerland 0800 850 810 Taiwan (886) 2 2378 3456 Turkey 90 216 309 1900 U.K. 01494 441181 U.S.A. 1-800-742-2345 B98-519 Contents Index
© Copyright 2024