LIGHTPLANE LINEAR UP AND UNDER SPECIFICATION GUIDE

LIGHTPLANE LINEAR UP AND UNDER
SPECIFICATION GUIDE
Architectural Lighting Works Ltd reserves the right to make changes to fixture design, finish and engineering at any time.
www.archltgworks.co.uk
2
3
LPLUUW - Wall (LPLUUW)
Specify in Millimetres
T5 - T5 Linear Fluorescent
LED CV - Constant Voltage LED Ribbons
LED CC - Standard Constant Current LEDs
LED HP - High Performance Philips Fortimo LEDs
T8 - T8 Linear Fluorescent
T5 SMS - T5 Seamless Linear Fluorescent
*Philips Fortimo, Tridonic Range and others available.
Consult factory if required.
R - Regular
O - Overlapping Lamps
WD - Lens (WD)
EXT -Extra Diffuse Lens (EXT)
LV - Louver (LV)
RO - Open, Reflector Only (RO)
DG - Flush guard lens - Indirect (DG)
137
57
WD - Lens (WD)
EXT -Extra Diffuse Lens (EXT)
LV - Louver (LV)
RO - Open, Reflector Only (RO)
7. Control Gear Specification:
STD - Standard Non Dimming
1-10V - 1-10V Dimming
DALI -DALI Dimming
OD -Contact Factory for other Dimming Options
220/240V - 220-240 volts
Other
* AL (Natural “Ultimatte” aluminium)
BK (Black powdercoat)
WH (White powdercoat)
RAL (Specify RAL # of powdercoat of your choice)
*AL is standard on all Lightplane UP and Under product
OS - Occupancy Sensor
PH - Photocell - Consult Factory (OS)
EM - Emergency
SB - Seismic Bracing - Consult Factory (SB)
Optional cover plate for J-Box included if needed.
Architectural Lighting Works Ltd reserves the right to make changes to fixture design, finish and engineering at any time.
www.archltgworks.co.uk
120
108
Page 3 of 3
610
915
1120 1525 1830
610
915
1120 1525
2135 2438
1830 2135
2745
3048 3355 3658
2438 2745 3048 3355
3658
Design Specifications
Construction
Extruded architectural grade T6061 aluminium. Minimum wall thickness is 2mm 100% recyclable.
Reflectors are formed from 1mm aluminium and finished in Titanium
white powdercoat.
Lenses are made from twin layered extruded high-impact acrylic.
WD is a full frosted/transparent combination.
EXT is a half frosted/white combination.
Single piece construction aluminium louver with clear matte anodised finish.
Electrical Details
All ballasts are electronic <10% THD
Class P electronic ballasts - Programmed start
Standard and dimming ballasts are integral to channel (unless otherwise noted).
LED options available (consult factory)
Multiple interface options availiable including dimming, motion sensing, daylight harvesting and DALI.
ETL Listed
Non-lensed units rated for Indoor location only.
Lensed units rated for damp location.
Emergency
Fixtures can be wired for emergency circuit or emergency battery
backup.
Emergency one-lamp ballasts provide 90 minutes of illumination.
T5/T5HO = Initial output of 1300 Lumens
Finish
All fixtures are standard in Ultimatte aluminium finish (AL) - A deep
etch and two-step clear anodising process that gives a smooth,
clean and durable surface.
Powder Coat options are available. Consult factory.
610
Architectural Lighting Works Ltd reserves the right to make changes to fixture design, finish and engineering at any time.
www.archltgworks.co.uk