LIGHTPLANE LINEAR UP AND UNDER SPECIFICATION GUIDE Architectural Lighting Works Ltd reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.co.uk 2 3 LPLUUW - Wall (LPLUUW) Specify in Millimetres T5 - T5 Linear Fluorescent LED CV - Constant Voltage LED Ribbons LED CC - Standard Constant Current LEDs LED HP - High Performance Philips Fortimo LEDs T8 - T8 Linear Fluorescent T5 SMS - T5 Seamless Linear Fluorescent *Philips Fortimo, Tridonic Range and others available. Consult factory if required. R - Regular O - Overlapping Lamps WD - Lens (WD) EXT -Extra Diffuse Lens (EXT) LV - Louver (LV) RO - Open, Reflector Only (RO) DG - Flush guard lens - Indirect (DG) 137 57 WD - Lens (WD) EXT -Extra Diffuse Lens (EXT) LV - Louver (LV) RO - Open, Reflector Only (RO) 7. Control Gear Specification: STD - Standard Non Dimming 1-10V - 1-10V Dimming DALI -DALI Dimming OD -Contact Factory for other Dimming Options 220/240V - 220-240 volts Other * AL (Natural “Ultimatte” aluminium) BK (Black powdercoat) WH (White powdercoat) RAL (Specify RAL # of powdercoat of your choice) *AL is standard on all Lightplane UP and Under product OS - Occupancy Sensor PH - Photocell - Consult Factory (OS) EM - Emergency SB - Seismic Bracing - Consult Factory (SB) Optional cover plate for J-Box included if needed. Architectural Lighting Works Ltd reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.co.uk 120 108 Page 3 of 3 610 915 1120 1525 1830 610 915 1120 1525 2135 2438 1830 2135 2745 3048 3355 3658 2438 2745 3048 3355 3658 Design Specifications Construction Extruded architectural grade T6061 aluminium. Minimum wall thickness is 2mm 100% recyclable. Reflectors are formed from 1mm aluminium and finished in Titanium white powdercoat. Lenses are made from twin layered extruded high-impact acrylic. WD is a full frosted/transparent combination. EXT is a half frosted/white combination. Single piece construction aluminium louver with clear matte anodised finish. Electrical Details All ballasts are electronic <10% THD Class P electronic ballasts - Programmed start Standard and dimming ballasts are integral to channel (unless otherwise noted). LED options available (consult factory) Multiple interface options availiable including dimming, motion sensing, daylight harvesting and DALI. ETL Listed Non-lensed units rated for Indoor location only. Lensed units rated for damp location. Emergency Fixtures can be wired for emergency circuit or emergency battery backup. Emergency one-lamp ballasts provide 90 minutes of illumination. T5/T5HO = Initial output of 1300 Lumens Finish All fixtures are standard in Ultimatte aluminium finish (AL) - A deep etch and two-step clear anodising process that gives a smooth, clean and durable surface. Powder Coat options are available. Consult factory. 610 Architectural Lighting Works Ltd reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.co.uk
© Copyright 2024