Submittal Review Cover Sheet Project#: 11DB-C5-08-61-02-PS14 Project: 11-13-07 Fire Station # 2 Date: Submittal#: Architect# 12/30/13 20 Revision# 0 Owner# 1312 Bowman Street To: Clermont, FL 34711 Phone (352) 394-1032 Fax: (352) 394-1794 Submitter: Kevin Boutros City of Zephyrhills 5335 8th Street Zephyrhills, FL 33540 Phone: (813) 780-0022 Fax: (813) 780-0025 Our Job#: 50041 Sub or Supplier Fire Safety, Inc. P.O Box 17371, Clearwater, FL 33762-0371 Contact: Shane LeBlanc Spec# 210500 Paragraph Spec Description FIRE SUPPRESSION Item Name FIRE SUPPRESSION Item Type Comment Reason: Reviewed By Pillar Construction Group, LLC Review is for general design only. Subcontractor and or Supplier are responsible for dimensions, quantities, and full compliance with the requirements of the contract documents. Review or approval by the architect or engineer does not relieve the Subcontractor and or Supplier of the responsibilities required by the terms and conditions of the agreement with Pillar Construction Group, LLC. Date: By: AREA FOR OTHER REVIEW STAMPS AND COMMENTS: PILLAR CONSTRUCTION GROUP, LLC Date 12/30/13 By: Kevin Boutros No Exception Taken Make Corrections Noted Revise & Resubmit Rejected This shop drawing review is for general performance with contract documents only and does not relieve the subcontractor or fabricator of his responsibility for compliance with requirements of the drawings and specifications. Submittal# 20 Spec Section# 210500 Drawing# Form: SubOne-G1 12/30/13 Zephyrhills Fire Station #2 3810 6th Avenue. Zephyrhills, Florida Contractor: Pillar Construction Group, LLC. Architect: Canerday, Belfsky + Arroyo. Architects Fire Protection Consultant: Engineering Matrix, Inc. Installing Contractor: Fire Safety, Inc. P.O. Box 17371 Clearwater, Florida 33762-0371 Date: December 26th, 2013 Material Submittals Aboveground Fire Suppression Sprinkler Systems INDEX - Pipe and Fittings. (Aboveground Only) ------------------------------------------------- Page 1-10 • Pipe: Schedule 10, Grooved Pipes 1¼” and larger, Manufacturer: Allied or Equal • Pipe: Schedule 40, Threaded pipes up to 1½”, Manufacturer: Allied or Equal • Grooved Fittings, grooved pipes only, Manufacturer: Anvil SPF or Victaulic • Screwed Fittings, threaded pipes only, Ductile Iron, Manufacturer: Anvil SPF Ductile or Equal - Hangers and Supports ----------------------------------------------------------------- Page 11-13 • Rings, Beam Clamps, Rods, Manufacturer: Anvil - Sprinkler Heads ----------------------------------------------------------------------- Page 14-23 • Fire Sprinklers, Quick Response: Concealed, Pendent, Upright, and Horizontal Sidewall; Manufacturer: Reliable Schedule-10/Schedule-40 – M-COAT ® Submittal Data Sheet Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 – M-COAT® sprinkler pipe from Allied Tube & Conduit, you get UL listed and FM approved products. Although these products do not require separate approvals, Schedule-10/Schedule-40 – M-COAT gives you the extra quality assurance you demand. Our Sch-10 (1-1⁄4” – 8”) pipe and Sch-40 (1” – 2-1⁄2”) pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Schedule-10/Schedule-40 – M-COAT product can be “hot-dip” galvanized to meet FM requirements. Superior Coating Our advanced formula mill coating offers a clean, durable surface that is also paintready for custom color applications without special preparation. The internal surface of all black Fire Sprinkler pipe up to 4.5000” in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula “M-COAT”. American Made Able to meet “Buy American” requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Schedule-10 – M-COAT pipe is in compliance with ASTM A135, Type E Grade A, and NFPA 13. Schedule-40 – M-COAT pipe is in compliance with ASTM A135/A795, Type E Grade A, and NFPA 13. Both pipe products have a working pressure rating of 300 psi maximum and also meet the stringent requirement for the following tests: Welded Outlets, Hydrostatic Pressure, Side Wall Rupture, Vibration Test. Sch-40 – M-COAT Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m 1” 1.049 1.680 2.05 25 26.6 2.5 3.05 1¼” 1.380 2.270 2.93 32 35.1 4.36 4.36 1½” 1.610 2.720 3.61 40 40.9 4.0 5.37 2” 2.067 3.650 5.13 50 52.5 5.4 7.63 2½” 2.469 5.790 7.86 65 62.7 8.6 11.73 CRR – 1 – 1 – 1 – 1 – 1 – Sch-10 – M-COAT Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) In; mm In; mm Lbs/Ft; kg/m Lbs/Ft; kg/m 1¼” 1.442 1.810 2.525 32 36.6 2.7 3.75 1½” 1.682 2.080 3.04 40 42.7 3.1 4.52 2” 2.157 2.640 4.22 50 54.8 3.9 6.28 2½” 2.635 3.530 5.89 65 66.9 5.3 8.77 3” 3.260 4.330 7.94 75 82.8 6.4 11.82 4” 4.260 5.610 11.78 100 108.2 8.3 17.53 5” 5.295 7.77 17.33 125 134.5 11.56 25.80 6” 6.357 9.290 23.03 150 161.5 13.8 34.27 8” 8.249 16.490 40.15 200 209.5 24.5 59.75 CRR – 7.0955 – 5.6570 – 4.5827 – 3.5196 – 2.5550 – 1.6020 – 1.4874 – 1.0251 – 1.8365 – Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations:Comments: Customer Service (800) 882-5543 Fax: (800) 659-7730 • 16100 S Lathrop Ave. Harvey, IL 60426 • 11350 Norcom Rd. Philadelphia, PA 19154 • 2525 N 27th Ave. Phoenix, AZ 85009 www.alliedtube-sprinkler.com • 600 Dean Sievers Place Morrisville, PA 19067 ©2011 Atkore International, Inc. All Rights Reserved. STP-S5-4M-1111 FIG. SE-1 Short Pattern 90˚ Elbow SE-1 are short pattern products and are specifically designed for use in Fire Protection applications where economy is a factor. All products are is UL/ULC Listed, LPCB, VdS and FM Approved. Maximum working pressure for these products is 300 PSI. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. C to E O.D. VdS For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. SE-1 90˚ ELBOW MATERIAL SPECIFICATIONS Nominal Size O.D. Center to End Approx. Wt. Ea. In./DN(mm) In./mm In./mm Lbs./Kg CAST FITTINGS: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 COATINGS: q Rust inhibiting paint Color: ORANGE (standard) or q Hot Dipped Zinc Galvanized conforming to ASTM A-153 (optional) q Other available options: Example: RAL3000 or RAL9000 Series 2 2.375 23⁄4 1.5 50 60.3 70 0.7 21⁄2 2.875 3 2.1 65 73.0 76 1.0 3 3.500 33⁄8 3.6 80 88.9 86 1.6 4 4.500 4 5.8 100 114.3 102 2.6 6 6.625 51⁄2 11.8 150 168.3 140 5.3 18 8 8.625 67⁄8 21.1 16 200 219.1 175 9.6 Pressure Drop (ft. of Schedule 40 pipe) Additional sizes available, contact an Anvil Representative. SE-1 90˚ Elbow short pattern fitting – pressure drop 8 inch 6 inch 4 inch 3 inch 21/2 inch 2 inch 14 12 10 8 6 4 2 0 5 10 15 20 Flow Rate (ft./sec.) SPF™ short pattern fittings exceed the headloss requirements of NFPA 13. For Fig. SE-1 90˚ grooved end elbows use the value shown. Note: Above values are shown for Schedule 40 pipe to be consistent with industry practices. PROJECT INFORMATION APPROVAL STAMP Contractor: q Approved q Approved as noted q Not approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: FP-4.12 FIG. ST-1 Short Pattern Tee ST-1 are short pattern products that are specifically designed for use in Fire Protection applications where economy is a factor. All products are UL/ULC Listed, LPCB, VdS and FM Approved. Maximum working pressure for these products is 300 PSI. For the latest UL/ ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. C to E O.D. VdS C to E For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. ST-1 TEE MATERIAL SPECIFICATIONS Nominal Size O.D. Center to End Approx. Wt. Ea. In./DN(mm) In./mm In./mm Lbs./Kg 2 2.375 23⁄4 2.9 50 60.3 70 1.3 21⁄2 2.875 3 4.6 65 73.0 76 2.1 3 3.500 33⁄8 6.9 80 88.9 86 3.1 4 4.500 4 10.9 100 114.3 102 4.9 25.0 CAST FITTINGS: Ductile Iron conforming to ASTM A-536 COATINGS: q Rust inhibiting paint Color: ORANGE (standard) or q Hot Dipped Zinc Galvanized conforming to ASTM A-153 (optional) q Other available options: Example: RAL3000 or RAL9000 Series ST-1 90˚ Tee short pattern fitting – pressure drop 6.625 5 ⁄2 168.3 140 11.3 18 8 8.625 67⁄8 42.1 16 200 219.1 175 19.1 Pressure Drop (ft. of Schedule 40 pipe) 6 150 1 8 inch 6 inch 4 inch 3 inch 21/2 inch 2 inch 14 12 10 8 6 4 2 0 5 10 15 20 Flow Rate (ft./sec.) SPF™ short pattern fittings exceed the headloss requirements of NFPA 13. For Fig. ST-1 grooved end tee branch use 21/2 times the value shown. For Fig. ST-1 grooved end tee run use the value shown. Note: Above values are shown for Schedule 40 pipe to be consistent with industry practices. PROJECT INFORMATION APPROVAL STAMP Contractor: q Approved q Approved as noted q Not approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: FP-4.12 FIG. SK-1 Cap E to E SK-1 GROOVED CAP Nominal Size O.D. End to End Approx. Wt. Ea. In./DN(mm) In./mm In./mm Lbs./Kg 0.3 1 1.315 11⁄4 25 33.4 25 0.1 11⁄4 1.660 1 0.4 32 42.2 25 0.2 1 1 ⁄2 1.900 1 0.5 40 48.3 25 0.2 0.7 2 2.375 1 50 60.3 25 0.3 21⁄2 2.875 1 1.0 65 3 O.D. 73.0 3.000 25 1 0.4 0.9 76.1 3 76.1 3.500 25 1 0.4 1.5 80 88.9 25 0.7 4 4.500 11⁄16 2.7 100 114.3 27 1.2 5 5.563 11⁄16 4.4 125 61⁄2 O.D. 141.3 6.500 27 1 2.0 5.5 165.1 6 165.1 6.625 25 11⁄16 2.5 6.6 150 168.3 27 3.0 8 8.625 13⁄16 11.3 200 219.1 30 5.1 10* 10.750 11⁄4 21.0 250 273.1 32 9.5 12* 12.750 11⁄4 35.5 300 323.9 32 16.1 VdS For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. MATERIAL SPECIFICATIONS CAST FITTINGS: Ductile Iron conforming to ASTM-A536 COATINGS: q Rust inhibiting paint Color: ORANGE (standard) or q Hot Dipped Zinc Galvanized conforming to ASTM A-153 (optional) q Other available options: Example: RAL3000 or RAL9000 Series *Supplied as Style K-1 only. PROJECT INFORMATION APPROVAL STAMP Contractor: q Approved q Approved as noted q Not approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: FP-4.12 FIG. C-3 Lightweight Flexible Coupling The C-3 Coupling is a flexible light weight style which is ideal for fire protection services and other services where low pressure and ambient temperature conditions are expected. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. VdS For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. MATERIAL SPECIFICATIONS HOUSING: GASKETS: Materials Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Properties as designated in accordance with ASTM D-2000. ANSI BOLTS & HEAVY HEX NUTS: q Pre-Lubricated Grade “E” EPDM, Type A Gasket (Violet color code) Heat treated, oval-neck track head bolts conforming to ASTM A-183 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: q Rust inhibiting paint Color: ORANGE (standard) q Hot Dipped Zinc Galvanized (optional) q Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: q Standard Gruvlok q Gruvlok Xtreme™ required for dry pipe systems and freezer applications. -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok Xtreme™ Lubricant is required. q Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. q Grade “EP” EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: q Standard C Style q Flush Gap PROJECT INFORMATION APPROVAL STAMP Contractor: q Approved q Approved as noted q Not approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: FP-4.12 FIG. C-3 Lightweight Flexible Coupling Z Y X C-3 LIGHTWEIGHT FLEXIBLE COUPLING Deflection From CL Max. Range of Max. End Working Pipe End Load Pipe Pressures Separation Per Coupling Nominal Size Pipe O.D. In./DN(mm) In./mm PSI/bar Lbs./kN In./mm Degrees 1 1.315 300 407 0-1⁄32 1° 22' 25 33.4 20.7 1.81 0-0.79 11⁄4 1.660 300 649 0-1⁄32 32 42.2 20.7 2.89 0-0.79 11⁄2 1.900 300 851 0-1⁄32 40 48.3 20.7 3.78 0-0.79 2 2.375 300 1,329 0-1⁄32 Coupling Dimensions X Y Z Coupling Bolts Qty. In./Ft. - mm/m In./mm In./mm In./mm 0.29 21⁄2 4 13⁄4 23.8 64 102 44 1° 5' 0.23 23⁄4 41⁄4 13⁄4 18.8 70 111 44 0° 57' 0.20 3 41⁄2 13⁄4 16.5 76 117 44 0° 45' 0.16 33⁄8 5 17⁄8 In./mm 2 2 2 2 50 60.3 20.7 5.91 0-0.79 13.1 66 140 48 21⁄2 2.875 300 1,948 0-1⁄32 0° 37' 0.13 37⁄8 51⁄2 17⁄8 2 65 3 O.D. 73.0 2.996 20.7 300 8.66 2,115 0-0.79 0-1⁄32 0° 36' 10.9 0.13 99 41⁄8 146 53⁄4 48 17⁄8 76.1 3 76.1 3.500 20.7 300 9.41 2,886 0-0.79 0-1⁄32 0° 31' 10.4 0.11 105 41⁄2 146 61⁄8 48 17⁄8 M10 x 50 40 60 0.6 ⁄8 x 21⁄4 30 45 1.5 3 M10 x 50 40 60 0.7 ⁄8 x 21⁄4 30 45 1.7 3 2 M10 x 57 1 ⁄2 x 21⁄2 40 30 60 45 0.9 2.6 156 48 61⁄8 8 21⁄4 2 100 51⁄2 O.D. 114.3 5.500 20.7 300 21.22 7,127 0-2.38 0-3⁄32 0° 59' 55.5 0.54 156 67⁄8 203 95⁄16 57 21⁄4 139.7 5 139.7 5.563 20.7 300 31.70 7,292 0-2.38 0-3⁄32 0° 58' 45.4 0.54 175 7 237 95⁄16 125 61⁄2 O.D. 141.3 6.500 20.7 300 32.44 9,955 0-6.4 0-3⁄32 0° 50' 45 0.46 178 77⁄8 165.1 6 165.1 6.625 20.7 300 44.28 10,341 0-2.38 0-3⁄32 0° 49' 34.8 0.45 200 81⁄4 37.8 210 273 57 0° 37' 0.35 105⁄8 131⁄2 21⁄2 29.1 270 343 64 0-2.38 1.3 0.9 1.9 114 77.97 45 60 45 8.9 20.7 30 40 30 0.67 219.1 0.5 ⁄8 x 21⁄4 3 1.2 M10 x 57 3 ⁄8 x 21⁄4 1° 12' 200 60 2 0-3⁄32 0-3⁄32 40 0.8 0-0.79 0-2.38 M10 x 57 2.0 12.84 46.00 45 60 4,771 17,528 30 45 20.7 20.7 ⁄8 x 21⁄4 40 300 300 Lbs./Kg 3 30 88.9 168.3 Ft.-Lbs./N-m Approx. Wt. Ea. ⁄8 x 21⁄4 4.500 8.625 Max. 3 4 8 Min. M10 x 57 80 150 Size Specified Torque § M10 x 63 40 60 1.2 5 ⁄8 x 31⁄2 80 100 4.1 2 M12 x 70 5 ⁄8 x 31⁄2 110 100 150 130 1.9 5.5 57 21⁄4 2 M16 x 89 5 ⁄8 x 31⁄4 135 100 175 130 2.5 5.7 237 101⁄2 57 21⁄4 2 M16 x 85 5 ⁄8 x 31⁄4 135 100 175 130 2.6 6.1 267 103⁄4 57 21⁄4 2 M16 x 85 5 ⁄8 x 31⁄4 135 100 175 130 2.8 6.1 2 M16 x 85 135 175 2.8 ⁄4 x 41⁄4 130 180 11.9 M20 x 110 175 245 5.4 3 Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. 1. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. 2. One time field test pressure may be increased to 1.5 times the figures listed above. § – For additional Bolt Torque information see Technical Data Section. s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure FP-4.12 ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok® Xtreme™ Lubricant is required. Print http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1962 Page 1 of 1 9/26/2011 Print http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1965 Page 1 of 1 9/26/2011 Print http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1966 Page 1 of 1 9/26/2011 Print http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1969 Page 1 of 1 9/26/2011 PIPE RINGS Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range: 1⁄2" through 8" Material: Carbon steel Finish: Galvanized Service: Recommended for suspension of non-insulated stationary pipe line. Maximum Temperature: 650° F Approvals: Complies with Federal Specification A-A-1192A (Type 10), WW-H-171-E (Type 10), ANSI/MSS SP-69 and MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes 3⁄4" - 8"). Features: • Threads are countersunk so that they cannot become burred or damaged. • Knurled swivel nut provides vertical adjustment after piping is in place. • Captured swivel nut in the 1⁄2" through 6" sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if desired, but not allowing the nut to fall completely out. Ordering: Specify size, figure number and name. Note: The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. Metric nut available upon request. Non-captured nut also available upon request. A B F Fig. 69: Loads (lbs) • Weight (lbs) • Dimensions (in) Pipe Size Max Load Weight 1 ⁄2 3 ⁄4 1 11⁄4 11⁄2 2 21⁄2 3 4 5 6 8 300 525 650 1,000 0.10 0.10 0.10 0.10 0.10 0.11 0.20 0.20 0.30 0.54 0.65 1.00 Rod Size A 3 ⁄8 1 ⁄2 B C F 27⁄8 23⁄4 29⁄16 25⁄8 23⁄4 31⁄4 4 313⁄16 411⁄16 55⁄16 611⁄16 8 2 17⁄8 111⁄16 13⁄4 17⁄8 23⁄8 23⁄4 215⁄16 313⁄16 43⁄8 59⁄16 7 19⁄16 15⁄16 1 G Width CL G 1 /2" through 1" pipe 5 /8 7 ⁄8 A 11⁄8 15⁄16 13⁄16 19⁄16 21⁄4 211⁄16 C F 3 /4 1 C B CL Note: Reflects changes in rod diameter from previously published data per recent revisions in MSS-SP-58 & 69 G 11/4" through 8" pipe PROJECT INFORMATION APPROVAL STAMP Contractor: q Approved q Approved as noted q Not approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: PH-11.11 BEAM CLAMPS Fig. 92 Universal C-type Clamp (Standard Throat) Size Range: 3⁄8" and 1⁄2" Material: Ductile iron, hardened steel cup point set screw and locknut. Finish: TPlain or TGalvanized Service: Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3⁄4". Approvals: Complies with Federal Specification A-A-1192A (Type 19 & 23) WW-H-171-E (Type 23), ANSI/MSS SP-69 and MSS SP-58 (Type 19 & 23). UL, ULC Listed and FM Approved. How to size: Size of clamp is determined by size of rod to be used. Installation: Follow recommended set screw torque values per MSS-SP-69 (See table on page 233) Features: • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. • Secured in place by a cup-pointed Set Screw tightened against the flange. A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. Ordering: Specify rod size, figure number, name of clamp and finish. H C F E AT LEAST ONE FULL THREAD OF ROD MUST BE EXPOSED G 3⁄4" D BODY CASTING A JAM - NUT SET SCREW 1" FIG. 92: LOAD (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) • TORQUE (IN-LBS) Rod Size Set Screw A Size 3 3 1 1 ⁄8 ⁄2 ■ Torque Value ⁄8 ⁄2 60 125 Max Loads ■ Top Bottom 500 950 250 760 Weight C D 0.34 0.63 15⁄16 13⁄8 19⁄16 113⁄16 E 9 ⁄16 ⁄2 1 F G 13 3 1 1 7 23 ⁄16 1 ⁄16 ⁄8 ⁄16 Maximum temperature of 450° F PROJECT INFORMATION APPROVAL STAMP Contractor: TApproved TApproved as noted TNot approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: PH-11.11 H ⁄2 ⁄32 HANGER RODS Fig. 146 Continuous Threaded Rod Size Range: 1⁄4" through 1 1⁄2" Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel or Stainless Steel Gr 304 Threads: National Coarse (USS), rod threaded complete length. Finish: TPlain or TGalvanized. Maximum Temperature: 650° F. Ordering: Specify rod diameter and length, figure number, name and finish. Note: The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. FIG. 146: LOADS (LBS) • WEIGHTS (LBS) • DIMENSIONS (IN) Rod Size A 1 Length ⁄4 ⁄8 1 ⁄2 5 ⁄8 3 ⁄4 7 ⁄8 1 11⁄4 11⁄2 3 A Threads per Inch Max Load 650˚ F Weight per Ft. 20 16 13 11 10 9 8 7 6 240 730 1,350 2,160 3,230 4,480 5,900 9,500 13,800 0.12 0.30 0.53 0.84 1.20 1.70 2.30 3.60 5.10 Note: Other rod sizes available upon request. Class 2 fit is available upon request. PROJECT INFORMATION APPROVAL STAMP Contractor: TApproved TApproved as noted TNot approved Engineer: Remarks: Project: Address: Submittal Date: Notes 1: Notes 2: PH-11.11 Bulletin 014 Rev. J Bulletin 014 Rev. J Model F1FR Series Quick Response Standard Spray Model F1FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Horizontal Sidewall Concealed Pendent Recessed Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Model F1FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Sprinkler Types Standard Upright Standard Pendent Model F1FR42, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Pendent Model F1FR56LL & F1FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhütung GmbH 5. *NSF Certified to NSF/ANSi Standard 61 Annex G UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass XLH Recessed bulb is specially constructed to provide Pendent FP fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. Model F1FR42, F1FRXLH Upright Technical data: Models Discharge Coefficient F1FR56 **F1FR56LL(1) K 5.6 F1FR42 **F1FR42LL(1) F1FRXLH K 4.2 F1FR28 K 2.8 (1) Response Quick Response Thread Size 1/2” NPT (R1/2) Max. Working Pressure Min. Working Pressure Temperature Rating Finish 175 PSI 7 PSI See “Temperature Ratings” Table. See “Finish Table” Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass QM Brass **Low Lead Brass CDA Alloy 260, CDA Alloy 220 or CDA Alloy510 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 360 or CDA Alloy 544 CDA Alloy 651 or CDA Alloy 693 Nickel Alloy 440 or Alloy 360 coated with PTFE Adhesive Tape Glass 2. Model F1FR56, Upright, Pendent & Conventional Sprinklers Model F1FR42, F1FRXLH & F1FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Thread Nominal Orifice Size Nominal K Factor US Metric Sprinkler Approval Height Organization Sprinkler Identification Number (SIN) Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2” (15mm) 1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1,2,3,4 RA1425(1)(2)(3) RA1414(1)(2)(3) 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1 RA1423(1) RA1413 3/8” (10mm) 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) 1 RA1421 RA1411 (1) (1) Conventional-Install in Upright or Pendent Position 15mm 1/2” NPT (R1/2) (1) 5.6 80 57mm 3, 4 RA1475(3) cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. (3) Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. (1) (2) Conventional Pendent Upright Model F1FR56LL & F1FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Thread Nominal Orifice Size Nominal K Factor US Metric Sprinkler Approval Sprinkler Identification Number (SIN) Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2” (15mm) (1) 7/16” (11mm) (1) 1/2” NPT (R1/2) 5.6 80 2.25” (57mm) 1,5 RA1414 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) 1,5 RA1413 cULus listed corrosion resistant (Polyester coated) sprinkler. 3. Model F1FR56, F1FR42, F1FRXLH & F1FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: (1) K Factor Nominal Orifice Thread Size Metric Sprinkler Height Sprinkler Identification Number (SIN) US 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1414 7/16” (10mm) 3/8” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1413 1/2” NPT (R1/2) 2.8 40 2.25” (57mm) RA1411 Refer to escutcheon data table for approvals & dimensions Model F1FR56LL & F1FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: (1) K Factor Nominal Orifice Thread Size US Metric Sprinkler Height Sprinkler Identification Number (SIN) 1/2” (15mm) 1/2” NPT(R½) 5.6 80 2.25” (57mm) RA1414 7/16” (10mm) 1/2” NPT (R1/2) 4.2 60 2.25” (57mm) RA1413 Refer to escutcheon data table for approvals & dimensions Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 F1 or F2 Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model F1FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: (1) (2) Nominal K Factor Nominal Orifice Thread Size ½” (15mm) 15mm ½” NPT (R1/2) ½” NPT (R1/2) US Metric Sprinkler Height 5.6 5.6 8.0 8.0 2.25” (57mm) 2.25” (57mm) Approval Organizations Sprinkler Identification Numbers (SIN) 1,2,3,4 4(1) RA1485(2) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Vertical Sidewall 4. Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright Pendent 4” (102mm) - 12” (305mm) 4” (102mm) - 12” (305mm) Model F1FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Nominal Orifice ½” (15mm) (1) (2) Thread Size ½” NPT (R1/2) US Metric 5.6 80 Sprinkler Height 2.63” (67mm) Approval Organizations and Type of Approval Light Hazard Ordinary Hazard 1,2 1 Sprinkler Identification Numbers (SIN) RA1435(1)(2) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: “K” Factor Nominal Orifice US ½” (15mm) Temp. Rating Sprinkler Cover Max. Ambient Temp F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange ½” NPT F1FR 155°F/68°C 135°F/57°C 100°F/38°C Red 80 ½” NPT F1FR 175°F/79°C 165°F/74°C 100°F/38°C 80 ½” NPT F1FR 200°F/93°C 165°F/74°C 150°F/65°C Metric Thread Size Model 5.6 80 ½” NPT ½” (15mm) 5.6 80 ½” (15mm) 5.6 ½” (15mm) 5.6 (1) Bulb Color Approvals Sprinkler Identification Number(SIN) 1 RA1414 1, 4 RA1414 Yellow 1 RA1414 Green 1 RA1414 (1) For VdS only = 155°F/68°C Norbulb and 1/2” [12,7mm] adjustment. Model F1FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: “K” Factor Nominal Orifice US Metric ½” (15mm) 5.6 80 Thread Size Temp. Rating Model Sprinkler ½” NPT F1FR56LL 200°F/93°C Cover Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) 165°F/74°C 150°F/65°C Green 1, 5 RA1414 5. Figure 1 Figure 2 Installation Aid gagement. A choice of two cover plate assemblies provide either 1/2” (13mm) or 5/8” (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 25/8” (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprinkler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for installing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½” NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the ½” orifice, ½” NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C). The Model F1FR56LL Pendent is available only in a rating of 200°F (93°C). The concealed sprinkler assemblies are completed by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the F1FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en*DuPont Registered Trade Mark 6. Finishes (1) Temperature Ratings Sprinkler Max. Ambient Classification Temperature Bulb Color Temp. °C °F Ordinary Ordinary Intermediate Intermediate High (1) (1) 57 68 79 93 141 135 155 175 200 286 100°F (38°C) 100°F (38°C) 150°F (66°C) 150°F (66°C) 225°F (107°C) Sprinkler Bronze Chrome Plated Polyester Coated (4)(5)(6) Orange Red Yellow Green Blue Standard Finishes Escutcheon Brass Chrome Plated White Painted Cover plate(1) Chrome White Special Application Finishes Sprinkler Escutcheon Cover plate(1) Bright Brass (3) Black Plated Black Paint (2)(6) Off White (2)(6) Satin Chrome Not available for recessed sprinklers. Escutcheon Data (1) SIN RA1435 – cULus permits use with F1, F2 or FP escutcheons for “light hazard” only, while FM limits use for same hazard with F2 escutcheon only. (1) Bright Brass Black Plated Black Paint Off White Satin Chrome Bright Brass Satin Off White Black Paint Black Plated Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed “corrosion resistance” applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as “Polyester coated” applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. (1) Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model 10. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Note: When Model F1FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) 7. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/13 P/N 9999970300
© Copyright 2024