Air Conditioning Technical Data Wall mounted unit EEDEN13-004A FTXN-L9 • Indoor Unit • Wall mounted unit • FTXN-L9 TABLE OF CONTENTS FTXN-L9 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Dimensional Drawings 4 ............................................... 5 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Piping Diagrams 5 ..................................................... 6 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Wiring Diagrams - Single Phase 6 3 4 .................................... 7 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Sound Level Data • Split - Sky Air • Indoor Unit .................................................... 9 1 • Indoor Unit • Wall mounted unit • FTXN-L9 1 ket Sti n uU - o 9 mr tL o - i ol N l dl X pnaT •ISWF • 1 1 • Features Indoor unit silent operation: "silent" button on the remote control lowers the operation sound of the indoor unit by 3dBA • Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room Titanium apatite photocatalytic air purification filter removes airborne microscopic particles, powerfully decomposes odours and helps to prevent the propagation of bacteria, viruses, microbes to ensure a steady supply of clean air • Powerful mode can be selected for rapid heating or cooling; after the powerful mode is turned off, the unit returns to the preset mode. • Flat, stylish front panel blends easily within any interior décor and is more easy to clean 24 hour timer can be set to start heating or cooling anytime during a 24 hour period Fan only Indoor unit Comfortable Powerful mode Auto coolingsilent operation sleeping mode heating changeover Titanium apatite 24 hour timer Infrared remote control photocatalytic air purification filter 2 Auto-restart Self diagnosis • Split - Sky Air • Indoor Unit Vertical auto Auto fan speed swing Fan speed steps Dry programme • Indoor Unit • Wall mounted unit • FTXN-L9 2 Specifications 2-1 Technical Specifications Power input Casing Dimensions Weight Packing Heat exchanger FTXN25L9 FTXN35L9 FTXN50L9 FTXN60L9 1.535 1.920 1.500 1.710 Cooling Nom. kW 0.740 1.025 Heating Nom. kW 0.700 0.930 Colour White Material High impact polystyrene Height/Width/ Depth mm 288/800/212 310/1,065/229 Packed unit Height/Width/ Depth mm 350/894/280 386/1,136/314 Unit kg 9.0 14.0 Packed unit kg 10.5 15.5 kg Length mm 1.5 610 858 Quantity 2 Fin pitch mm Face area m² Stages Quantity Empty tubeplate hole Quantity 1.4 0.18 0.29 14 16 0 Tube type Hi-X Tube material Copper Tube diameter Fin mm 7.0 Type ML fin (Multi louver) Slit fin Treatment Hydrophilic Type Cross flow fan Quantity Air flow rate 1 Cooling Super high High Nom. Low Silent operati on Heating Super high High Nom. Low Silent operati on External static pressure 2 EPS / Corrugated board Weight Rows Fan 1 Unit Material 3 m³/min 10.7 11.1 16.4 cfm 378 392 578 703 m³/min 9.8 10.1 15.0 18.5 cfm 345 358 529 654 m³/min 7.7 8.0 13.3 16.6 cfm 272 282 471 585 m³/min 6.1 6.6 11.8 14.4 cfm 215 232 19.9 418 507 m³/min 4.7 10.6 12.4 cfm 165 374 437 19.9 m³/min 10.7 11.1 16.4 cfm 378 392 578 703 m³/min 9.8 10.1 15.3 18.9 cfm 345 358 542 667 m³/min 7.7 8.0 13.3 16.6 cfm 272 282 471 585 m³/min 6.1 6.6 11.8 14.4 cfm 215 418 507 m³/min 4.7 232 10.6 12.4 cfm 165 374 437 Super high Pa 0 High Pa 0 Nom. Pa 0 Low Pa 0 • Split - Sky Air • Indoor Unit 3 • Indoor Unit • Wall mounted unit • FTXN-L9 2 Specifications 2-1 Technical Specifications Fan motor FTXN25L9 FTXN35L9 FTXN50L9 Quantity Model MWM10/15J-501 MWMY20/25JR Index of Protection 1 20 Insulation grade Class "E" Poles 2 FTXN60L9 1 4 8 Drive Direct drive Speed Steps 3 steps, turbo, quiet, auto rpm Cooling High/ Mediu m/Low/ Silent operati on 1,240/1,020/850/700 1,280/1,050/900/700 1,050/960/870/800 1,250/1,140/1,010/900 rpm Heating High/ Mediu m/Low/ Silent operati on 1,240/1,020/850/700 1,280/1,050/900/700 1,090/960/870/800 1,280/1,140/1,010/900 Phase x Voltage V 1 x 230V DC310 Full load amps (FLA) Cooling A 0.19 0.21 0.32 0.56 Heating A 0.19 0.21 0.33 0.56 Sound power level Cooling High dBA 53 54 55 61 Sound pressure level Cooling Super high/High/ Nom./Low/Silent operation dBA 41/40/34/29/21 42/41/34/30/22 44/40/38/35/32 46/43/41/37/33 Heating Super high dBA Refrigerant Type Piping connections Liquid Type/OD mm Gas Type/OD mm R-410A Flare valve/6.35 Flare valve/9.5 Flare valve/12.7 Drain Heat insulation Both liquid and gas pipes Temperature control Microcomputer control Air direction control Right, Left, Horizontal, Downward Air filter Flare valve/15.9 16.5 Type Titanium apatite Quantity pc 2 Standard Accessories : Titanium apatite filters; Standard Accessories : Mounting plate; Standard Accessories : Remote control holder; Standard Accessories : Batteries; Standard Accessories : Wireless remote control; Standard Accessories : Operation manual; Standard Accessories : Installation manual; 2-2 Electrical Specifications Power supply FTXN25L9 FTXN35L9 Name Current Current - 50Hz Wiring connections 50Hz 4 FTXN60L9 V1 Phase Voltage range FTXN50L9 1~ Frequency Hz 50 Voltage V 220-240 Min. % -10 Max. % Nominal running Cooling current (RLA) - 50Hz Heating A 4.07 4.92 6.84 8.59 A 3.86 5.12 6.72 7.63 Maximum running current A 7.19 Maximum fuse amps (MFA) A For power supply 10 7.21 10.0 16 20 Quantity 3 Remark 3 for power supply, 4 for interunit wiring (Earth wire included) • Split - Sky Air • Indoor Unit • Indoor Unit • Wall mounted unit • FTXN-L9 3 Dimensional drawings 3-1 Dimensional Drawings 3 1 3 • Split - Sky Air • Indoor Unit 5 • Indoor Unit • Wall mounted unit • FTXN-L9 4 Piping diagrams 4-1 Piping Diagrams 1 4 6 • Split - Sky Air • Indoor Unit • Indoor Unit • Wall mounted unit • FTXN-L9 5 Wiring diagrams 5-1 Wiring Diagrams - Single Phase 3 1 5 • Split - Sky Air • Indoor Unit 7 • Indoor Unit • Wall mounted unit • FTXN-L9 5 Wiring diagrams 5-1 Wiring Diagrams - Single Phase 1 5 8 • Split - Sky Air • Indoor Unit • Indoor Unit • Wall mounted unit • FTXN-L9 6 Sound data 6-1 Sound Level Data 3 1 6 • Split - Sky Air • Indoor Unit 9 • Indoor Unit • Wall mounted unit • FTXN-L9 6 Sound data 6-1 Sound Level Data 3 1 6 • Split - Sky Air • Indoor Unit 10 • Indoor Unit • Wall mounted unit • FTXN-L9 6 Sound data 6-1 Sound Level Data 3 1 6 • Split - Sky Air • Indoor Unit 11 The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN13-004A • 04/13 • Copyright Daikin The present publication supersedes EEDEN12-004A Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com”
© Copyright 2024