null

Air Conditioning
Technical Data
Wall mounted unit
EEDEN13-004A
FTXN-L9
• Indoor Unit • Wall mounted unit • FTXN-L9
TABLE OF CONTENTS
FTXN-L9
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Dimensional Drawings
4
............................................... 5
Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Piping Diagrams
5
..................................................... 6
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring Diagrams - Single Phase
6
3
4
.................................... 7
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sound Level Data
• Split - Sky Air • Indoor Unit
.................................................... 9
1
• Indoor Unit • Wall mounted unit • FTXN-L9
1
ket Sti n uU - o 9 mr tL o - i ol N l dl X pnaT •ISWF
•
1
1
•
Features
Indoor unit silent operation: "silent" button on the remote control
lowers the operation sound of the indoor unit by 3dBA
•
Vertical auto swing moves the discharge flaps up and down for
efficient air and temperature distribution throughout the room
Titanium apatite photocatalytic air purification filter removes airborne
microscopic particles, powerfully decomposes odours and helps to
prevent the propagation of bacteria, viruses, microbes to ensure a
steady supply of clean air
•
Powerful mode can be selected for rapid heating or cooling; after the
powerful mode is turned off, the unit returns to the preset mode.
•
Flat, stylish front panel blends easily within any interior décor and is
more easy to clean
24 hour timer can be set to start heating or cooling anytime during a
24 hour period
Fan only
Indoor unit
Comfortable
Powerful mode Auto coolingsilent operation sleeping mode
heating
changeover
Titanium apatite 24 hour timer Infrared remote
control
photocatalytic
air purification
filter
2
Auto-restart
Self diagnosis
• Split - Sky Air • Indoor Unit
Vertical auto Auto fan speed
swing
Fan speed
steps
Dry programme
• Indoor Unit • Wall mounted unit • FTXN-L9
2
Specifications
2-1 Technical Specifications
Power input
Casing
Dimensions
Weight
Packing
Heat exchanger
FTXN25L9
FTXN35L9
FTXN50L9
FTXN60L9
1.535
1.920
1.500
1.710
Cooling
Nom.
kW
0.740
1.025
Heating
Nom.
kW
0.700
0.930
Colour
White
Material
High impact polystyrene
Height/Width/
Depth
mm
288/800/212
310/1,065/229
Packed unit
Height/Width/
Depth
mm
350/894/280
386/1,136/314
Unit
kg
9.0
14.0
Packed unit
kg
10.5
15.5
kg
Length
mm
1.5
610
858
Quantity
2
Fin pitch
mm
Face area
m²
Stages
Quantity
Empty tubeplate
hole
Quantity
1.4
0.18
0.29
14
16
0
Tube type
Hi-X
Tube material
Copper
Tube diameter
Fin
mm
7.0
Type
ML fin (Multi louver)
Slit fin
Treatment
Hydrophilic
Type
Cross flow fan
Quantity
Air flow rate
1
Cooling Super
high
High
Nom.
Low
Silent
operati
on
Heating Super
high
High
Nom.
Low
Silent
operati
on
External static
pressure
2
EPS / Corrugated board
Weight
Rows
Fan
1
Unit
Material
3
m³/min
10.7
11.1
16.4
cfm
378
392
578
703
m³/min
9.8
10.1
15.0
18.5
cfm
345
358
529
654
m³/min
7.7
8.0
13.3
16.6
cfm
272
282
471
585
m³/min
6.1
6.6
11.8
14.4
cfm
215
232
19.9
418
507
m³/min
4.7
10.6
12.4
cfm
165
374
437
19.9
m³/min
10.7
11.1
16.4
cfm
378
392
578
703
m³/min
9.8
10.1
15.3
18.9
cfm
345
358
542
667
m³/min
7.7
8.0
13.3
16.6
cfm
272
282
471
585
m³/min
6.1
6.6
11.8
14.4
cfm
215
418
507
m³/min
4.7
232
10.6
12.4
cfm
165
374
437
Super high
Pa
0
High
Pa
0
Nom.
Pa
0
Low
Pa
0
• Split - Sky Air • Indoor Unit
3
• Indoor Unit • Wall mounted unit • FTXN-L9
2
Specifications
2-1 Technical Specifications
Fan motor
FTXN25L9
FTXN35L9
FTXN50L9
Quantity
Model
MWM10/15J-501
MWMY20/25JR
Index of Protection
1
20
Insulation grade
Class "E"
Poles
2
FTXN60L9
1
4
8
Drive
Direct drive
Speed
Steps
3 steps, turbo, quiet, auto
rpm
Cooling High/
Mediu
m/Low/
Silent
operati
on
1,240/1,020/850/700
1,280/1,050/900/700
1,050/960/870/800
1,250/1,140/1,010/900
rpm
Heating High/
Mediu
m/Low/
Silent
operati
on
1,240/1,020/850/700
1,280/1,050/900/700
1,090/960/870/800
1,280/1,140/1,010/900
Phase x Voltage
V
1 x 230V
DC310
Full load amps
(FLA)
Cooling
A
0.19
0.21
0.32
0.56
Heating
A
0.19
0.21
0.33
0.56
Sound power level
Cooling
High
dBA
53
54
55
61
Sound pressure level
Cooling
Super high/High/
Nom./Low/Silent
operation
dBA
41/40/34/29/21
42/41/34/30/22
44/40/38/35/32
46/43/41/37/33
Heating
Super high
dBA
Refrigerant
Type
Piping connections
Liquid
Type/OD
mm
Gas
Type/OD
mm
R-410A
Flare valve/6.35
Flare valve/9.5
Flare valve/12.7
Drain
Heat insulation
Both liquid and gas pipes
Temperature control
Microcomputer control
Air direction control
Right, Left, Horizontal, Downward
Air filter
Flare valve/15.9
16.5
Type
Titanium apatite
Quantity
pc
2
Standard Accessories : Titanium apatite filters;
Standard Accessories : Mounting plate;
Standard Accessories : Remote control holder;
Standard Accessories : Batteries;
Standard Accessories : Wireless remote control;
Standard Accessories : Operation manual;
Standard Accessories : Installation manual;
2-2 Electrical Specifications
Power supply
FTXN25L9
FTXN35L9
Name
Current
Current - 50Hz
Wiring connections 50Hz
4
FTXN60L9
V1
Phase
Voltage range
FTXN50L9
1~
Frequency
Hz
50
Voltage
V
220-240
Min.
%
-10
Max.
%
Nominal running
Cooling
current (RLA) - 50Hz Heating
A
4.07
4.92
6.84
8.59
A
3.86
5.12
6.72
7.63
Maximum running current
A
7.19
Maximum fuse amps (MFA)
A
For power supply
10
7.21
10.0
16
20
Quantity
3
Remark
3 for power supply, 4 for interunit wiring (Earth wire included)
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXN-L9
3
Dimensional drawings
3-1
Dimensional Drawings
3
1
3
• Split - Sky Air • Indoor Unit
5
• Indoor Unit • Wall mounted unit • FTXN-L9
4
Piping diagrams
4-1
Piping Diagrams
1
4
6
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXN-L9
5
Wiring diagrams
5-1
Wiring Diagrams - Single Phase
3
1
5
• Split - Sky Air • Indoor Unit
7
• Indoor Unit • Wall mounted unit • FTXN-L9
5
Wiring diagrams
5-1
Wiring Diagrams - Single Phase
1
5
8
• Split - Sky Air • Indoor Unit
• Indoor Unit • Wall mounted unit • FTXN-L9
6
Sound data
6-1
Sound Level Data
3
1
6
• Split - Sky Air • Indoor Unit
9
• Indoor Unit • Wall mounted unit • FTXN-L9
6
Sound data
6-1
Sound Level Data
3
1
6
• Split - Sky Air • Indoor Unit
10
• Indoor Unit • Wall mounted unit • FTXN-L9
6
Sound data
6-1
Sound Level Data
3
1
6
• Split - Sky Air • Indoor Unit
11
The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.
has compiled the content of this leaflet to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products
and services presented therein. Specifications are subject to change
without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
BARCODE
Daikin products are distributed by:
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
EEDEN13-004A • 04/13 • Copyright Daikin
The present publication supersedes EEDEN12-004A
Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages
(LCP), Air handling units (AHU) and Fan coil
units (FCU), Check ongoing validity of certificate
online:
www.eurovent-certification.com or using: www.certiflash.com”