Y2 Series of High-voltage Compact type Three-phase Induction Motors Sample Book

Enterprise Standard of Jiamusi Electric Machine Co., Ltd.
0EE.138.177-2007
Y2 Series of High-voltage Compact type
Three-phase Induction Motors
Sample Book
Promulgated on December 31, 2007
Effective as of January 1, 2008
Issued by Jiamusi Electric Machine Co., Ltd.
0EE.138.176-2007
Y2 series of High-voltage Compact type Three-phase Induction Motor
Sample Book
ⅠGeneral
The motors are mainly used in the areas of explosive gas atmosphere, for example:
petroleum, chemical industry, coal, power plant, metallurgy, traffic, spinning and weaving,
medicine, grain processing, etc. or so of general-purpose machine, such as fan, water pump,
compressor, crusher, trimming machine tool, transport machinery etc., or other similar
mechanical equipments.
ⅡSelection guide
1
Meaning of motor type
Y
2
400
1
—2
W
Induction motor
Outdoors(symbol of protection type)
Design no.
Shaft height
No. of poles
The core length symbol for the same
frame
2. The type of series motor
2.1 The capacity of Y2 series high-voltage compact type three-phase induction motors(3kV、
6kV)see Table1
Table 1
Synchronous speed
Frame size
3000
1500
r/min
1000
750
Power kW
355
400
450
500
1
185
185
—
—
2
200
200
—
—
3
220
220
160
—
4
250
250
185
—
5
280
280
200
—
1
315
315
220
160
2
355
355
250
185
3
400
400
280
200
4
450
450
315
220
1
500
500
355
250
2
560
560
400
280
3
630
630
450
315
4
710
710
500
355
1
800
800
560
400
2
900
900
630
450
3
1000
1000
710
500
4
1120
1120
800
560
1
0EE.138.176-2007
Table 1(continue)
Synchronous speed r/min
Frame size
3000
1500
1000
750
Power kW
560
1
1250
1250
900
630
2
1400
1400
1000
710
3
1600
1600
1120
800
4
—
—
1250
900
The capacity of Y2 series high-voltage compact type three-phase induction motors
(10kV)see Table2
Table 2
Synchronous speed r/min
Frame size
3000
1500
1000
750
Power kW
2.2
450
500
560
3.
1
220
220
—
—
2
250
250
—
—
3
280
280
—
—
4
315
315
220
—
5
355
355
250
—
6
400
400
280
220
7
450
450
315
250
8
500
500
355
280
1
560
560
400
—
2
630
630
450
315
3
710
710
500
355
4
800
800
560
400
5
900
900
630
450
1
1000
1000
710
500
2
1120
1120
800
560
3
1250
1250
900
630
4
1400
1400
1000
710
5
-
-
1120
800
Voltage class and frequency
The motor rated voltage contain 3kV, 6kV and 10kV three kinds of voltage according to
the user different geographic position, corresponding rated frequency of power supply is
50Hz. The motor also can be made into other voltage class or frequency on request of the
user. All the technical data in this sample book is under the frequency of 50Hz.
2
0EE.138.176-2007
4. Insulation class and temperature rise limit value
The insulation class of the motor usually uses F class of insulation.
The temperature rise limit value of the motor which winding indirect cooled by air:
On the basis of motor operating site altitude above sea level not exceed 1000m and max.
ambient temperature not exceed 40℃, the temperature rise limit value of class B
insulation is 80K, and 105K for F class of insulation.
5.
Bearing construction type and temperature limit value
The motors are provided with rolling bearings and sleeve bearings, which construction
type of bearing can be decided according to overall and mounting dimensions data sheet,
normal product with sleeve bearing construction use forced lubrication, but also can be
made into self-lubrication according to request; the motor rolling bearing
permitted
temperature shall not exceed 95℃, the permitted temperature for sleeve bearing with
forced lubrication shall not exceed 80℃ and for sleeve bearing with self lubrication not
exceed 95℃.
6.
Degree of protection
Degree of protection by enclosure of motor is IP44, IP54 and IP55 according to the
different operating conditions of the motor, the meaning explanation of the feature as
follows:
The marking of protection degree is composed of expression letters (“IP”) and two
suffixal expression numbers, the first number means each degree of the first kind of
protection and the second number means each degree of the second kind of protection.
IP
5
4
The second expression number:represents the protection degree of harmful influence
caused by water entering into enclosure(water-proof
degree)
The first expression number:represents the protection degree of people to enclosure
and to internal parts in enclosure(dust-proof degree)
Expression letters
Brief introduction of the meaning of expression number“4”and“5”in degree of
protection:
The first expression number“4”means the motor can prevent the solid body more than
1mm from entering into it;
The first expression number “5” means the enclosure can prevent from touching or
closing the charged or rotating parts in it, the enclosure can’t completely prevent dust
3
0EE.138.176-2007
from entering into it, but the quantity of the entering dust isn’t enough to affect the
normal operation of the motor.
The second expression number“4”means the harmful influence should not be caused
when the motor bears the splash from any direction (splash-proof motor).
The second expression number“5”means the harmful influence should not be caused
when the motor bears the spray from any direction (spray-proof motor).
For detail knowledge related to degree of protection see GB4942.1.
7. Cooling method
The marking of cooling method is composed of symbol letters “IC” and following
numbers, “IC” is abbreviation of English word “International Cooling”.
The cooling method of Y2 series of high-voltage compact type three-phase induction
motors is IC411, the meaning of letters and numbers as follows:
IC
4
1
1
`Symbol letters
Arrangement of cooling circuit
Driving method of primary coolant motion
Driving method of secondary coolant motion
Arrangement of cooling circuit:4 represents cooling at surface of frame
Coolant motion driving method: 1 represents self-circulation: cooling medium motion
related to motor rotating speed, usually by fan mounted on the rotor.
Coolant: divided into primary coolant and secondary coolant, coolant usually use air (A)
and water (W), etc.
Primary coolant: a medium, liquid or gas, which, being at a lower temperature than a part
of a machine and in contact with it, removes heat from that part.
Second coolant: a medium, liquid or gas, which, being at a lower temperature than the
primary coolant, removes the heat given up by this primary coolant by means of a heat
exchanger or through the external surface of the machine.
8.
Weather-protected type and operation environment conditions
1)Weather-proof types are:
a. Damp and tropical climate type, indoor (TH); outdoor (THW);
b. Dry and tropical climate type, indoor (TA); outdoor (TAW);
c. Tropical climate type, indoor (T); outdoor (TW)
d. Outdoor light corrosion-proof type (W)
e. Outdoor middle corrosion-proof type (WF1)
4
0EE.138.176-2007
f. Outdoor strong corrosion-proof type (WF2)
g. Indoor middle corrosion-proof type (F1)
h. Indoor strong corrosion-proof type (F2)
The protection type mentioned above shall be marked at the end of motor type, for
example: Y2 5001-4WF1.
2)The operating environmental conditions of each whether-proof type motor under
different locations are as follows:
a. Operating environment conditions include: climatic conditions (K), special climate
conditions (Zh-thermal radiation, Za-surrounding air movement, Zw- water
source other than rainfall), biotic conditions (B), chemical active material
conditions(C), mechanical active material conditions(S) and mechanical
conditions (M) altogether six categories.
b. Operating location of the motor can be divided into:
Weather protected location: Indoors or have good shield location (the structure
construction can prevent or reduce the influence of outdoor climate daily change,
include shed condition), the number ahead of environment condition class is “3”,
simplified as indoor condition.
Non weather protected location: Locations completely in the open air or only has
simple cover (can hardly prevent the influence of outdoor climate daily change),
the number ahead of environment condition class is “4”.
9.
Connection method
Connection method of all the high-voltage motor is Y connection.
10.
Cable entry
In normal condition the motor is provided with rubber sleeve cable entries, and also can
provide steel tube connection units or armoured cable fittings according to the user’s request.
11.
Duty
Duty type of motor is continuous (S1).
12. Performance index allowance
Efficiency η:-10%(1-η)
Power factor cos φ:-(1-cosφ)/6
Min. absolute value 0.02
Max. absolute value 0.07
Locked-rotor current:+20% of current guaranteed value
5
0EE.138.176-2007
Locked-rotor torque:+25%/-15% of torque guaranteed value
(the value of +25% may be exceeded through negotiation )
Min. torque:-15% of torque guaranteed value
Max. torque:-10% of torque guaranteed value
Ⅲ Operation conditions of motor in site
1. Altitude above sea level of the motor normal operating locations is up to 1000m.
2. The max. ambient air temperature shall not exceed +40℃.
3. The min. ambient air temperature should not be lower than -20℃, the min. ambient
air temperature of sleeve bearing motors should not be lower than 0℃.
4.Voltage and frequency allowance value:
The motor can continuously operate at area A( voltage deviation is –5%~+5% of rated
value, frequency deviation is –2%~+2% of rated value) and reach its basic performance, but
the performance in this range differs from that at rated voltage and frequency( see rated point
in Fig.1), such as, the temperature rise of motor can be higher than that at rated voltage and
frequency. If the motor operate at the border A, the temperature rise can be higher 10℃ than
that at rated point.
The motor can operate at area B( voltage deviation is –10%~+10% of rated value,
frequency deviation is –5%~+3% of rated value) and reach its basic performance, but the
performance difference between at point of this area and rated voltage and frequency should
be higher than that between at point of area A and rated voltage and frequency, the
temperature rise of motor can be higher than that at rated voltage and frequency and can be
higher than that at area A. The motor should not continuously operate at the border B.
Other electric operation condition of motor should be in accordance with GB755.
Fig.1
Limits of voltage and frequency of motor
6
0EE.138.176-2007
Ⅳ Construction features
Y2 Series of High-Voltage Compact type Three-phase Induction Motor is the latest-generation motor
with high efficiency, energy saving and environmental protecting advantages. It is designed and
manufactured on the basis of experiences of years of manufacturing motors, through the analysis of
construction field, electromagnetic field, fluid field and compound field by large finite element analysis,
and through the principle of double circulated cooling and ventilating system. This series of motors have
advantages of small volume, light weight, compact conformation, good appearance and smooth lines etc.
1.
Cooling air path, frame and end shield
Y2 series of motors has two independent cooling air paths: internal cooling air path and
external cooling air path (see Fig.2), most of the loss heat transmit from stator core to motor
frame, and then bring away by external cooling air, the rest loss heat transmit to motor frame
through internal cooling circuit and take away by external cooling air.
Fig. 2
The motor frame use quadrature distributed total cooling fin casting frame, between
cooling fins use nonisometric distribution and discentric circle combination method, 4 axial
air duct are provided at 45°direction. Because of the motor frame has reduced scale, outer
cooling air from non-driving end can reach to driving end more effectively through cooling
fins, so as to achieve the best cooling effect. The terminal box is located at upper motor side
where air duct has placed in order to not influence heat dissipation and the flowing of cooling
air. The frame inner surface around stator winding end provided with heat absorption rib.
Frame enough large area of dissipation with rib type construction guaranteed powerful heat
sinking ability.
Two lifting rings are opposite angle mounted on the air duct (the angle of lifting rings can
be random adjusted) to make the motor hoisting more convenient.
The end shield of driving end and non-driving end has the same structure; heat sinking rib
is provided for inner and outer of end shield to enhance the end shield stiffness and heat
7
0EE.138.176-2007
sinking ability. High strength casting iron motor frame and end shield ensured the motor has
high stability.
2 Low noise fan
On the precondition of the cooling effect has been satisfied, the fan and fan cover use
streamline design construction, so as to improve fan efficiency and reduce fan noise.
External fan: 2 poles: propeller type axial fans (unidirectional rotation); shaft height
H355-H400, 4 poles and above motor use convex centrifugal fan and can be bidirectional
rotated. H450 and above, 4 poles motor use backward tilting type centrifugal fan, only
suitable for one direction of rotation; motors with other poles use convex centrifugal fan and
suitable for both directions.
Internal fan: Radial centrifugal fan (can be bidirectional rotated).
3 Stator
The motor has a laminated core first compressed and secured before it is fitted into the
frame and then pressed into the machined frame.The stator windings are class F insulated,
anticorona treatment(10kV),the ends of windings are boneded and fixed firmly, and the
windings are vacuum pressure impregnated with solventless varnish. Therefore, the motors
have good and reliable insulating performance, higher mechanical strength, long service
life,as well as higher moisture-resistance, corrosion resistance and anticorona ability.
4
Rotor
The further aim of this series of motors is cast aluminum rotor technology, which has already proved
to be successful in millions of low-voltage and high-voltage motors and then popularized to large capacity
motor. The rotor busbar and short circuit ring casting into an integral part. This technology ensured the
solidity of the structure and the unique stability of the cast rotor. Use centrifugal cast aluminum technique
pouring the liquid state aluminum into rotor lamination core slot, the mould is pouring at one shot, the short
circuit ring and the busbar are pouring at the same time.
5
Bearing
There are two kinds of bearings: rolling bearings and sleeve bearings. Usually the motor use rolling
bearings, sleeve bearings are used for motors which the service conditions (depending on rotating speed,
load and operating conditions) exceed the limit value.
The DE and NDE bearings for standard designed motor H500-2 (3kV、6kV、10kV) and
H560-2(3kV、6kV、10kV)are end-shield type spherical sleeve bearings, forced lubrication
and the insulation treatment is provided for NDE. Permit axial play at free state is ±5mm, in
this case the motor rotor and shaft system must be axial located by “caging device” on driven
8
0EE.138.176-2007
equipment. H500-2(10kV) also has rolling bearings; other motors use rolling bearings and
have oil inlet and outlet device(without shutdown the motor), can fill up the lubrication
grease and discharge the waste grease during motor operation.
6
Terminal box
According to the different explosion-proof requirement, the terminal box for main power
supply is increased-safety type steel plate tension terminal box, and has the advantage of
beautiful appearance, lower weight, suitable for motors with 3kV, 6kV and 10kV voltage, and
high generalization degree.
Standard designed motor have two terminal boxes, namely main terminal box and
auxiliary terminal box. The main terminal box can be mounted at four different positions on
motor frame ventilating slot in order to meet the different connection requirement at site. If
there is no special requirement, the main terminal box should located at DE right upper side
(viewed from motor shaft extension end), cable inlet from bottom. The auxiliary terminal
box is located at NDE right upper side (viewed from motor shaft extension end), cable inlet
from bottom.
7
Monitoring and protection
Standard designed motors provided with these monitoring and protection devices: stator
winding temperature detector platinum resistance PT100, bearing temperature detector
platinum resistance PT100 and anti-condensation space heater. All the connecting wire of
temperature detector and heater are connected into the connecting terminals of auxiliary
terminal box.
Ⅴ Performance data:
1 For the data sheet of Y2(6kV)series of high-voltage compact type three-phase induction motors, see
table 3(calculated value)
9
0EE.138.176-2007
Table 3
Type
Rated
Rated
Rated
Efficie
Power
power
current
torque
ncy
factor
(kW)
(A)
(r/min)
(%)
cosΦ
Max.
torque
Rated
torque
Locked-
Locked-
rotor
rotor
torque
current
Motor
Permissib
Rated
Rated
Jm
le load J
torque
current
(kg.m2)
(kg.m2)
Moment of inertia
Weight
(kg)
Y2
3551-2
185
20.9
94.8
2.0
13.6
2035
Y2
3552-2
200
22.5
95.1
2.5
14.8
2080
Y2
3553-2
220
24.7
95.4
2.4
16.2
2155
Y2
3554-2
250
28.0
95.6
2.5
19.1
2195
0.90
Y2
3555-2
280
31.3
95.8
2.8
21.6
2240
Y2
4001-2
315
35.2
95.8
4.3
21
2730
Y2
4002-2
355
39.6
95.9
4.5
24
2810
Y2
4003-2
400
44.5
96.0
4.9
29
2925
Y2
4004-2
450
50.0
96.2
5.3
32
3015
Y2
4501-2
500
54.9
6
43
3475
Y2
4502-2
560
61.5
6.2
50
3610
Y2
4503-2
630
69.2
6.8
58
3770
7.5
64
3910
15
85
5725
16
92
5855
2985
96.3
0.7
96.3
7.0
96.3
Y2
4504-2
710
77.8
96.5
Y2
5001-2
800
87.7
96.5
Y2
5002-2
900
98.6
96.5
Y2
5003-2
1000
109.5
96.6
17
103
5990
Y2
5004-2
1120
122.3
96.8
19
107
6230
Y2
5601-2
1250
136.4
96.9
28
119
7475
Y2
5602-2
1400
151.1
96.9
30
135
7765
Y2
5603-2
1600
172.5
97.0
32
165
8085
Y2
3551-4
185
22.1
94.6
4.8
89
2175
Y2
3552-4
200
23.9
94.8
5.4
95
2250
Y2
3553-4
220
26.2
95.0
5.8
105
2310
Y2
3554-4
250
29.7
95.2
Y2 3555-4
280
33.2
95.5
Y2 4001-4
315
37.3
Y2 4002-4
355
Y2 4003-4
Y2 4004-4
0.91
0.92
2.0
6.1
112
3345
6.4
138
2385
95.6
8.0
150
2935
41.9
95.9
8.5
170
3035
400
47.1
96.1
9.3
200
3120
450
52.3
9.8
220
3190
Y2 4501-4
500
58.1
13
240
3850
Y2 4502-4
560
65.1
96.3
15
260
4045
Y2 4503-4
630
73.1
96.4
16
290
4310
Y2 4504-4
710
81.3
96.6
18
320
4550
Y2 5001-4
800
91.5
96.7
33
330
5540
Y2 5002-4
900
102.9
96.7
35
380
5730
Y2
5003-4
1000
114.3
96.8
37
440
5845
Y2
5004-4
1120
127.9
96.9
39
510
5970
Y2
5601-4
1250
142.7
96.9
63
750
7575
1488
0.85
96.2
96.3
0.8
0.86
0.87
6.5
10
0EE.138.176-2007
Table 3 (continue)
Type
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Y2
Rated
Stator
Rated
Efficie
Power
power
current
torque
ncy
factor
(kW)
(A)
(r/min)
(%)
cosΦ
5602-4
5603-4
3553-6
3554-6
3555-6
4001-6
4002-6
4003-6
4004-6
4501-6
4502-6
4503-6
4504-6
5001-6
5002-6
5003-6
5004-6
5601-6
5602-6
5603-6
5604-6
4001-8
4002-8
4003-8
4004-8
4501-8
4502-8
4503-8
4504-8
5001-8
1400
1600
160
185
200
220
250
280
315
355
400
450
500
560
630
710
800
900
1000
1120
1250
160
185
200
220
250
280
315
355
400
156.1
178.0
20.1
23.2
25.1
27.2
30.4
34.0
38.2
43.0
48.5
54.5
60.4
67.6
75.9
85.4
96.1
106.7
118.5
132.4
147.6
21.6
24.9
26.5
29.1
32.6
36.4
40.9
46.1
50.5
Y2 5002-8
450
56.6
95.6
Y2
Y2
Y2
Y2
Y2
Y2
500
560
630
710
800
900
62.8
70.3
78.0
88.0
98.9
111.1
95.7
95.8
95.9
95.9
96.1
96.2
5003-8
5004-8
5601-8
5602-8
5603-8
5604-8
1488
987
742
97.0
97.2
94.4
94.6
94.8
94.9
95.4
95.5
95.7
95.7
95.7
95.8
96.0
96.1
96.2
96.4
96.5
96.6
96.7
96.9
97.0
93.9
94.1
94.3
94.5
94.7
94.8
95.0
95.1
95.3
Max.
torque
Rated
torque
Locked-
Locked-
rotor
rotor
torque
current
Rated
Rated
torque
current
0.89
0.81
6.5
0.82
0.83
6.0
0.84
2.0
0.8
0.76
0.77
0.78
5.5
0.80
0.81
Moment of inertia
Motor Jm
(kg.m2)
Permissible
load J
Weight
(kg)
(kg.m2)
68
76
6.5
7.0
7.8
11.8
12.5
13.3
14.3
16
18
20
22
44
46
48
51
97
101
106
113
12.5
13.0
14.0
15.3
16
18
20
22
44
810
910
202
235
254
270
306
340
390
420
490
550
620
910
1020
1150
1310
1116
1265
1411
1586
390
450
490
540
600
630
660
690
590
7885
8245
2330
2395
2480
2950
3000
3110
3220
3960
4170
4370
4570
5725
5845
6120
6300
7350
7620
7840
8095
2930
2975
3085
3205
3955
4155
4355
4560
5720
46
650
5840
48
51
120
128
134
710
790
1390
1571
1780
6110
6290
6860
7145
7370
140
2017
7610
2 For the data sheet of Y2 (10kV)series of high-voltage compact type three-phase induction motors, see
table 4(calculated value).
11
0EE.138.176-2007
Table 4
Type
Rated
Rated
Rated
Efficie
Power
power
current
torque
ncy
factor
(kW)
(A)
(r/min)
(%)
cosΦ
Max.
torque
Rated
torque
Locked-
Locked-
rotor
rotor
torque
current
Motor
Permissible
Rated
Rated
Jm
load J
torque
current
(kg.m)
(kg.m2)
5.6
14
2875
6.5
15
3015
Moment of inertia
Weight
(kg)
Y2 4501-2
220
16.0
94.6
Y2 4502-2
250
18.1
94.7
Y2 4503-2
280
19.8
94.9
7.4
18
3155
Y2 4504-2
315
22.2
95.1
8.6
21
3315
Y2 4505-2
355
25.0
95.2
9.1
26
3400
Y2 4506-2
400
28.1
95.5
9.7
31
3480
Y2 4507-2
450
31.6
95.6
10.2
36
3525
Y2 4508-2
500
34.7
10.8
41
3615
Y2 5001-2
560
38.8
12
60
4970
Y2 5002-2
630
43.6
14
70
5090
Y2 5003-2
710
49.0
96.0
15
85
5220
Y2 5004-2
800
54.6
96.1
16
92
5330
Y2 5005-2
900
61.4
96.2
17
103
5460
Y2 5601-2
1000
68.1
96.3
19
94
6860
Y2 5602-2
1120
75.3
96.4
28
98
7160
Y2 5603-2
1250
83.9
96.5
30
111
7495
Y2 5604-2
1400
93.9
96.6
32
126
7795
Y2 4501-4
220
16.0
94.6
12.9
105
3025
Y2 4502-4
250
18.1
94.7
Y2 4503-4
280
20.3
94.9
Y2 4504-4
315
22.5
95.1
Y2 4505-4
355
25.3
95.2
Y2 4506-4
400
28.5
95.5
0.84
0.86
95.7
2985
95.8
95.9
Y2 4507-4
450
32.0
95.6
Y2 4508-4
500
35.1
95.7
Y2 5001-4
560
39.2
Y2 5002-4
630
44.1
95.9
Y2 5003-4
710
49.6
96.0
Y2 5004-4
800
55.2
96.1
Y2 5005-4
900
62.1
96.2
Y2 5601-4
1000
68.9
96.3
Y2 5602-4
1120
76.2
96.4
Y2 5603-4
1250
85.0
96.5
Y2 5604-4
1400
95.1
Y2 4504-6
220
16.4
Y2 4505-6
250
Y2 4506-6
Y2 4507-6
1488
95.8
0.7
0.87
7.0
0.88
0.89
0.84
2.0
0.85
0.8
6.5
0.86
14.8
120
3150
16.9
135
3305
19.2
150
3455
20.3
163
3525
21.6
175
3570
22.5
188
3645
23.6
200
3730
31
290
5045
33
330
5205
35
380
5305
37
440
5450
39
510
5565
58
617
6725
63
692
7020
68
775
7315
96.6
76
868
7710
94.2
27.4
225
3500
18.7
94.3
28.8
238
3565
280
20.9
94.5
30.2
252
3645
315
23.4
94.7
33.0
264
3795
Y2 4508-6
355
26.3
34.9
280
3900
Y2 5001-6
400
29.6
95.0
43
510
5090
Y2 5002-6
450
32.9
95.1
44
590
5240
Y2 5003-6
500
36.5
95.2
46
650
987
0.87
0.88
0.7
0.82
0.8
94.9
0.83
6.0
5350
12
0EE.138.176-2007
Table 4(continue)
Type
Rated
Rated
Rated
Efficie
Power
power
current
torque
ncy
factor
(kW)
(A)
(r/min)
(%)
cosΦ
Y2 5004-6
560
40.8
95.5
Y2 5005-6
630
45.8
95.6
Y2 5601-6
710
51.6
95.7
Y2 5602-6
800
58.1
95.8
Y2 5603-6
900
64.4
Y2 5604-6
1000
71.5
96.1
Y2 5605-6
1120
80.0
96.2
Y2 4506-8
220
17.5
94.1
Y2 4507-8
250
19.6
94.2
Y2 4508-8
280
22.0
94.3
Y2 5002-8
315
24.7
94.4
Y2 5003-8
355
27.8
94.6
Y2 5004-8
400
30.9
94.7
Y2 5005-8
450
34.7
Y2 5601-8
500
38.5
95.0
Y2 5602-8
560
42.5
95.1
987
Max.
torque
Rated
torque
94.8
Y2 5603-8
630
47.7
95.3
Y2 5604-8
710
53.0
95.5
Y2 5605-8
800
59.6
95.6
Locked-
rotor
rotor
torque
current
Rated
Rated
torque
current
0.8
0.83
6.0
0.7
96.0
742
Locked-
0.84
0.77
0.78
2.0
0.8
5.5
0.79
0.80
0.81
0.7
Moment of inertia
Motor
Jm
(kg.m)
Permissible
load J
Weight
(kg)
(kg.m2)
48
710
5495
51
790
5635
93
984
6950
97
1116
7220
101
1265
7495
106
1411
7740
113
1586
8010
30
394
3635
33
406
3770
35
419
3890
43
820
5150
44
870
5295
46
950
5405
48
1010
5575
113
1236
6525
120
1390
6760
128
1571
7005
134
1780
7230
140
2017
7470
13
0EE.138.177.2007
Ⅵ、Overall and mounting dimensions drawing
1、Overall and mounting dimensions for Y2 (3kV、6kV)series of high-voltage compact type three-phase induction motors
Mounting dimension and tolerance
No.
Frame
of
size
poles
355
400
2
4-6
2
A
B
Basic dim. Basic dim.
630
710
C
D
E
F
Basic dimension
Basic
dim.
dim.
dev.
dim.
dev.
dim.
75
+0.030
+0.011'
140
±0.50
20
210
±0.57
28
dev.
900 254
100
85
1000
4-8
280
2
450 4 800 1120
6-8
425
2
*
500 4 900 1250
315
6-8
530
2
*
560 4 1000 1400
355
6-8
Dimension Basic dimension Basic
±4.0
110
95
120
130
110
130
140
130
150
160
170
+0.035
+0.013
+0.040
+0.015
+0.035
+0.013
210
170
210
250
210
22
±0.50
±0.57
+0.040
+0.015
250
300
±0.65
Overall dimension (limited value)
G
Dimension
dev.
H
dimen
Dimens
Basic dim. sion Basic dim.
ion
dev.
dev.
67.5
355
90
0
-0.052
28
25
32
0
-0.062
28
32
36
32
36
40
0
-0.052
0
-0.062
K
76
100
86
109
119
100
119
128
119
138
147
Basic
dim.
dimens
ion
AB
AC
AD
AG
BA
BB
BC
BD
28
790
750 780 730 240 1110
217 112
160 870
840 830 745 240 1200 200 115
950
910 855 790 240 1340 165 136
35
-0.2
450
+0.62
0
0
-1.0
500
0
-0.3
0
-0.2
200 1080 1035 910 820 300 1490 264 114
42
560
GD
H
A
HB
HD
L
dev.
400
0
-0.3
AA
210 1170 1185 955 870 300 1680
178 170
14
16
14
16
14
18
16
18
20
18
20
22
210 1010
50
335 1110
1770
1840
1900
2000
2070
50 370 1170 2150
2250
2580
50 490 1290 2380
2485
2900
60 595 1400 2600
2775
* In order to select the motor size of sleeve bearing, the axial play can be defined by manufacturer and client.
12
0EE.138.177.2007
2、Overall and mounting dimensions for Y2(10KV)series of high-voltage compact type three-phase induction motors
Mounting dimension and tolerance
Frame
size
450
500
560
No. of
poles
Ca
A
B
Basic
Basic
Basic
dim.
dim.
dim.
D
dimens
ion
dev.
2
4 800 1120 280
6-8
315
2
±4.0
4 900 1250
315
6-8
2
530*
4 1000 1400
355
6-8
Basic
dim.
E
Dimens
ion
dev.
95 +0.035
+0.013
120
130 +0.040
+0.015
100 +0.035
+0.013
Basic dimensio
dim.
Overall dimension (limited value)
F
n dev.
170 ±0.50
210
250
210
±0.57
130
140
250
+0.040
130 +0.015
150
300 ±0.65
160
Basic dim.
G
Dimensio Basic dimensio Basic
n
dev.
25
0
-0.052
32
0
-0.062
28
0
-0.052
32
36
32
36
40
H
0
-0.062
dim.
86
109
119
90
119
128
119
138
147
n dev.
dim.
K
Dimens
ion
dev.
450
Basic
dim.
dimen
sion
AA
AB
AC
AD
AG
BA
BB
BC
BD
500
0
-0.3
0
-0.2
0
-0.3
35
160 950 910
855 805 240 1340 165
+0.62
0
200 1080 1031 910 835
42
560
HA
HB
HD
L
14
2070
50 385 1170 2150
2250
dev.
136
0
-0.2
0
-1.0
GD
1490 264
114
1680 178
170
300
210 1170 1185 955 890
18
16
2580
18
20
18
20
22
50 490 1290 2380
2480
2900
60 595 1400 2600
2775
* In order to select the motor size of sleeve bearing, the axial play can be defined by manufacturer and client.
13
0EE.138.177.2007
Ⅶ The interface dimensions of site mounting of motor
1
In the main power supply there are three M16 connection terminals,the following diagram is overall
dimension drawing (6kV、10kV)of the terminal box:
2
The stator temperature detector, bearing temperature detector and heater are share one overall
dimensions drawing of auxiliary terminal box
3
Inner diameter of rubber sealing ring for the incoming line of the main power supply is shown in
the following diagram. The threaded interface also can be supplied,and the dimension of which is G3.
The stator temperature detector, bearing temperature detector and heater are share one auxiliary
terminal box, there are three interface. For the inner diameter of seal ring of cable entry, see above
diagram. The threaded interface also can be supplied, and the dimension of which is M24×2.
14
0EE.138.177.2007
4
The wiring diagram of terminal box for main power supply, stator temperature detector, bearing
temperature detector and heater see following diagram:
Ⅷ Ordering information
1. When selecting three-phase induction motors, the following matters must be taken into
account:
a. Operating environment, ambient temperature, altitude, etc.
b.Mechanical characteristic and moment of inertia for the driven device.
c. Starting method, starting frequency and starting voltage drop
d.Direction of rotation of motor
e. The mechenical connetion method and requirement between motor and driven
load
f. The position of terminal box.
g.Duty type and other special requirement
2. Motors supplied in the Sample book are standard motor design
a. The altitude for standard motor is not more than 1000m
b. The max. ambient temperature is not more than 40℃,and the min. is not lower
than -20℃, for motor of sleeve bearing or air-to-water cooling, the min. ambient
temperature is not lower than 0℃.
c. Direct on line and full voltage starting
d. CW. rotated for standard motors (as viewed from DE)
e. the main and auxiliary terminal boxes are on the right side of motor ( as viewed
from DE)
f. For the standard designed motors of sleeve bearings, normally provided with
forced lubrication and no pressure oil return.
15
0EE.138.177.2007
3. Normal ordering
The order without special requirements is normal order, the following parameters
should be noted when ordering.(eg.)
Type :Y2 5001-2
Rated voltage:6kV
Rated frequency: 50Hz
Rated power:800kW
No. of poles:2
Rated speed:2985r/min
Mounting arrangement: B3
Duty type: S1
Method of cooling: IC411
Degree of protection: IP54
Direction of rotation :CW.
Operating environment: indoors
Method of incoming line: rubber sleeve
4. Order with additional requirements
If there’s one or more requirements for the following items, it should be declared in
ordering.
4.1 The voltage are not 3000、6000 and 10000V,eg.:3.3kV、6.3kV;
4.2 Frequency is 60Hz;
4.3 Power is not the standard value in data sheet, or coincidence relations between power
and mounting demension are different from data sheet.
4.4 The altitude above sea level is more than 1000m.
4.5 Ambient temperature:more than 40℃, or the lowest temperature is less than -20℃.
4.6 Low noise: the noise is lower than the specification of GB10069
4.7Non-standard mounting arrangement: corrsponding relations between frame size and
mounting arrangement are different from data sheet.
4.8 The special environment needing declaring,for example: humid tropics, outdoors,
corrosion, salt spray, mold, dust and blown sand, etc., for corrosion, it must be listed for
taking corresponding measures according to the corrosiveness.
4.9 The direction of rotation of motor is CCW.
4.10 The special requirement for electric performance, eg: high locked-rotor torque, high
slip, high moment of inertia and low locked-rotor current, etc.
4.11 Other special requirements, eg.: protective relay device ( temperature monitoring
device for winding and bearing, differential protection), special bearing, special packing
and spare parts ahead of specification,etc.
4.12 If there’s above special requirements and other requirements, please negotiate with
our technical department or sign technical agreement.
4.13 With technical development of products and revisal of relevant standards at home
and aboard, technical data shown herein are subject to change without notice.
16