Sample Concentration MD200 series Sample Concentration The instrument consists of a base and stand assembly, sample holder and gas distribution system. Test tubes are held in a block.The gas at 5 to 10 psig passes through the distribution manifold. Depending on the test-tube size and solvent volume they can be individually raised or lowered to the correct height. Needles or glass pipets blow gas onto the surface of the solution resultingin rapid evaporation of the solvent. Specification: Model MD200-1 MD200-1A MD200-2 Temperature Control Range RT+5°C~150°C RT+5°C~150°C RT+5°C~150°C Timer 1min~99h59min 1min~99h59min 1min~99h59min Display LED LED LED Temp. Control Accuracy @40~100°C ±0.5°C ±0.5°C ±0.5°C Temp. Control Accuracy @100~150°C ±1°C ±1°C ±1°C Display Accuracy 0.1°C 0.1°C 0.1°C Heating Time(40~150°C) ≤30min ≤30min ≤30min Standard Blocks 1 1 2 Nitrogen Consumption 0-10L/min 0-10L/min 0-10L/min Dimension(mm) 280 x 240 x 110 280 x 240 x 110 280 x 240 x 110 Needle Length 150mm 80mm 150mm Code Description AS-06050-00 MD200-1 AC240V , 50 Hz, 200W AS-06060-00 MD200-1A AC240V , 50 Hz, 200W AS-06070-00 MD200-2 AC240V , 50 Hz, 400W AS-06051-01 150mm Needles AS-06061-01 80mm Needles AS-06051-02 Flow Control Valve Block for MD200 Series Sample Concentration Code Type Description Dimensions (mm) AS-01081-01 BK01 49xΦ6mm 96x96x49 AS-01081-02 BK02 AS-01081-03 BK03 49xΦ7mm 25xΦ10mm 96x96x49 96x96x49 AS-01081-04 BK04 25xΦ12mm 96x96x49 AS-01081-05 BK05 25xΦ13mm 96x96x49 AS-01081-06 BK06 12xΦ15mm 96x96x49 AS-01081-07 BK07 16xΦ15mm 96x96x49 AS-01081-08 BK08 12xΦ16mm AS-01081-09 BK09 16xΦ16mm 96x96x49 96x96x49 AS-01081-10 AS-01081-11 BK10 BK11 12xΦ19mm 16xΦ19mm 96x96x49 96x96x49 AS-01081-12 BK12 9xΦ20mm 96x96x49 AS-01081-13 BK13 9xΦ26mm 96x96x49 AS-01081-14 BK14 4xΦ28mm 96x96x49 AS-01081-15 BK15 4xΦ40mm 96x96x49 AS-01081-16 BK16 49x0.5ml tubes 96x96x49 AS-01081-17 BK17 25x1.5ml tubes 96x96x49 AS-01081-18 AS-01091-01 BK18 BK19 25x2.0ml tubes 96x0.2ml tubes 96x96x49 78x114x26 AS-01091-02 BK20 96x0.2ml microplate 81x123x19 REMARK: BK19, BK20 are used in MD200-1A ! MD200-1 MD200-1A Block MD200-2 Valve DAINTREE SCIENTIFIC Tel: (03) 6376 3335 Fax: (03) 6376 3334 E-mail: [email protected] www.daintreescientific.com.au Sample Concentration KD200 Sample Concentration Features: 1. 2. 3. 4. 5. 6. High precision and wide range of temp control Blowing a large number of samples at one time Blowing each sample independently Amount of airflow can be adjusted Easy operation; safe and reliable to use Low Nitrogen consumption of 330ml/min/sample Specification: 1. Temperature Control Range: 2. Temperature control discrepancy: 3. 4. 5. 6. 7. 8. 9. Heating time (from 40°C to 150°C): Processing timer: Maximum input power: Temp. control discrepancy: Deedles length: Capacity: Overall Dimensions (L xW x H): RT+5°C~150°C ≤±1°C (RT.+5°C~100°C) ≤±1.5°C(100°C~150°C) ≤30min 1min~99h59min 400W 0.1°C 150mm 12pcs 280x240x500mm Code Description AS-06090-00 KD200 AC20V , 50 Hz, 400W AS-06081-01 150mm Needles KD200 Block for KD200 Sample Concentration Code Type Description Dimensions (mm) AS-06091-01 BD01 12xΦ10mm 192x96x49 AS-06091-02 BD02 AS-06091-03 BD03 12xΦ12mm 12xΦ13mm 192x96x49 192x96x49 AS-06091-04 BD04 12xΦ15mm 192x96x49 AS-06091-05 BD05 12xΦ16mm 192x96x49 AS-06091-06 BD06 12xΦ19mm 192x96x49 AS-06091-07 BD07 12xΦ20mm 192x96x49 WD-12 Sample Concentration Observation positions The instrument consists of a base and stand assembly, sample holder and gas distribution system. Test tubes are held in place by a spring-loaded sample holder and support tray. Each position is numbered. The gas passes through an adjustable flow meter to the distribution manifold. Flexible tubing leads to valve-tube assemblies at each position. Depending on the test-tube size and solvent volume they can be individually raised or lowered to the correct height. Specification: 1. LED display, 12 positions 2. Water bath provides gentle heating 3. Circular stand turns so each sample is accessible from the front 4. Accommodates samples in test tubes 10 to 29mm diameter, volumes from 1 ml to 50 ml 5. A gas flow meter with valve, controls and indicates gas consumption 6. A needle valve adjusts gas flow at each position 7. Stainless steel 150mm- gauge needles standard 8. All metal parts are made of stainless steel, nickel chromed brass or anodized aluminum 9. Temperature setting range: Ambient temperature ~ 99°C 10.Temperature control accuracy: ±1°C Code Description AS-06080-00 WD-12 AC20V , 50 Hz, 1000W AS-06081-01 150mm Needles DAINTREE SCIENTIFIC Tel: (03) 6376 3335 Fax: (03) 6376 3334 E-mail: [email protected] www.daintreescientific.com.au 1
© Copyright 2024