Clayton Houston Professional Real Estate Inspector 1234 Paradise Lane Somewhere, Texas INVOICE Clayton Houston 7212 FM 879 Palmer, TX 75152 Phone (972)921-8454 [email protected] TREC 8059 SOLD TO: INVOICE NUMBER Sample Report 2 INVOICE DATE 10/03/2011 John & Jane Doe TX LOCATION <none> DATE REALTOR DESCRIPTION PRICE SUBTOTAL TAX TOTAL BALANCE DUE THANK YOU FOR YOUR BUSINESS! AMOUNT $0.00 $0.00 $0.00 $0.00 Clayton Houston Phone: (972)921-8454 Fax: (972)875-4144 Email: [email protected] 7212 FM 879 Palmer, TX 75152 PROPERTY INSPECTION REPORT Prepared For: John & Jane Doe (Name of Client) Concerning: 1234 Paradise Lane, Somewhere, TX (Address of Inspected Property) By: Clayton Houston, Lic #8059 10/03/2011 (Name and License Number of Inspector) (Date) (Name, License Number and Signature of Sponsoring Inspector, if required) This property inspection report may include an inspection agreement (contract), addenda, and other information related to property conditions. If any item or comment is unclear, you should ask the inspector to clarify the findings. It is important that you carefully read ALL of this information. This inspection is subject to the rules (“Rules”) of the Texas Real Estate Commission (“TREC”), which can be found at www.trec.state.tx.us. The TREC Standards of Practice (Sections 535.227-535.233 of the Rules) are the minimum standards for inspections by TREC-licensed inspectors. An inspection addresses only those components and conditions that are present, visible, and accessible at the time of the inspection. While there may be other parts, components or systems present, only those items specifically noted as being inspected were inspected. The inspector is not required to move furnishings or stored items. The inspection report may address issues that are code-based or may refer to a particular code; however, this is NOT a code compliance inspection and does NOT verify compliance with manufacturer’s installation instructions. The inspection does NOT imply insurability or warrantability of the structure or its components. Although some safety issues may be addressed in this report, this inspection is NOT a safety/code inspection, and the inspector is NOT required to identify all potential hazards. In this report, the inspector will note which systems and components were Inspected (I), Not Inspected (NI), Not Present (NP), and/or Deficient (D). General deficiencies include inoperability, material distress, water penetration, damage, deterioration, missing parts, and unsuitable installation. Comments may be provided by the inspector whether or not an item is deemed deficient. The inspector is not required to prioritize or emphasize the importance of one deficiency over another. Some items reported as Deficient may be considered life-safety upgrades to the property. For more information, refer to Texas Real Estate Consumer Notice Concerning Recognized Hazards, form OP-I. This property inspection is not an exhaustive inspection of the structure, systems, or components. The inspection may not reveal all deficiencies. A real estate inspection helps to reduce some of the risk involved in purchasing a home, but it cannot eliminate these risks, nor can the inspection anticipate future events or changes in performance due to changes in use or occupancy. It is recommended that you obtain as much information as is available about this property, including any seller’s disclosures, previous inspection reports, engineering reports, building/remodeling permits, and reports performed for or by relocation companies, municipal inspection departments, lenders, insurers, and appraisers. You should also attempt to determine whether repairs, renovation, remodeling, additions, or other such activities have taken place at this property. It is not the inspector’s responsibility to confirm that information obtained from these sources is complete or accurate or that this inspection is consistent with the opinions expressed in previous or future reports. ITEMS IDENTIFIED IN THE REPORT DO NOT OBLIGATE ANY PARTY TO MAKE REPAIRS OR TAKE OTHER ACTIONS, NOR IS THE PURCHASER REQUIRED TO REQUEST THAT THE SELLER TAKE ANY ACTION. When a deficiency is reported, it is the client’s responsibility to obtain Promulgated by the Texas Real Estate Commission (TREC), P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or (512) 459-6544 (http://www.trec.state.tx.us). REI 7-2 (8/09) Page 1 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX further evaluations and/or cost estimates from qualified service professionals. Any such follow-up should take place prior to the expiration of any time limitations such as option periods. Evaluations by qualified tradesmen may lead to the discovery of additional deficiencies which may involve additional repair costs. Failure to address deficiencies or comments noted in this report may lead to further damage of the structure or systems and add to the original repair costs. The inspector is not required to provide follow-up services to verify that proper repairs have been made. Property conditions change with time and use. For example, mechanical devices can fail at any time, plumbing gaskets and seals may crack if the appliance or plumbing fixture is not used often, roof leaks can occur at any time regardless of the apparent condition of the roof, and the performance of the structure and the systems may change due to changes in use or occupancy, effects of weather, etc. These changes or repairs made to the structure after the inspection may render information contained herein obsolete or invalid. This report is provided for the specific benefit of the client named above and is based on observations at the time of the inspection. If you did not hire the inspector yourself, reliance on this report may provide incomplete or outdated information. Repairs, professional opinions or additional inspection reports may affect the meaning of the information in this report. It is recommended that you hire a licensed inspector to perform an inspection to meet your specific needs and to provide you with current information concerning this property. ADDITIONAL INFORMATION PROVIDED BY INSPECTOR Present at Inspection: Buyer Selling Agent Building Status: Vacant Owner Occupied Weather Conditions: Fair Cloudy Utilities On: Yes No Water Special Notes: Two story, Single family home, Built in 2001, house faces North. Listing Agent Tenant Occupied Rain No Electricity Occupant Other Temp: 85 No Gas For the purpose of this report, this INACCESSIBLE OR OBSTRUCTED AREAS Sub Flooring Floors Covered Walls/Ceilings Covered or Freshly Painted Behind/Under Furniture and/or Stored Items Attic Space is Limited - Viewed from Accessible Areas Plumbing Areas - Only Visible Plumbing Inspected Siding Over Older Existing Siding Crawl Space is limited - Viewed From Accessible Areas Notice: Mold/Mildew investigations are NOT included with this report, it is beyond the scope of this inspection at the present time. Any reference of water intrusion, is recommended that a professional investigation be obtained. Errors – Report Interpretation: This report was prepared on a computer and infrequently a word or part of a sentence may be accidentally deleted or altered. Should you encounter such a condition, please contact me as soon as possible to make the necessary correction and provide you with a replacement page(s). If you do not understand certain comments or recommendations, call me prior to closing the transaction for clarification. Pictures - Pictures included with this report are intended to be one example of a deficient item noted in the report. The deficiency may be located at more than one area of the structure. The client accepting this Property Inspection Report, or relying on it in any way, expressly agrees to the Limitations, Departures and Disclaimers included in and with this inspection report. NOTICE: THIS REPORT IS PAID FOR BY AND PREPARED FOR THE CLIENT NAMED ABOVE. THIS REPORT IS NOT VALID WITHOUT THE SIGNED SERVICE AGREEMENT AND IS NOT TRANSFERABLE. REI 7-2 (8/09) Page 2 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected I NI=Not Inspected NP=Not Present D=Deficient NI NP D I. STRUCTURAL SYSTEMS A. Foundations Type of Foundation(s): Slab Comments: Signs of Structural Movement or Settling Mortar separation Cracks in brick, stone, or stucco Floors not level Pier/Beam Condition Separations between trim and siding Door / window frames out of square Cracks in wall(s) and/or ceiling Cracks in exposed concrete floors Cracks in Parge Coat Excessive or improper shims Beam splices not supported by piers Performance Opinion: (An opinion on performance is mandatory) Note: Weather conditions, drainage, leakage and other adverse factors are able to effect structures, and differential movements are likely to occur. The inspectors opinion is based on visual observations of accessible and unobstructed areas of the structure at the time of the inspection. Future performance of the structure cannot be predicted or warranted. The foundation appears to be performing the function intended. There were not any signs of structural movement or settling noted during the inspection today. It is important to note that the inspection is a cursory visual inspection of the foundation and structure. There was not any measuring devices used during this inspection. SUGGESTED FOUNDATION MAINTENANCE & CARE - Proper drainage and moisture maintenance to all types of foundations due to the expansive nature of the area load bearing soils. Drainage must be directed away from all sides of the foundation with grade slopes. In most cases, floor coverings and/or stored articles prevent recognition of signs of settlement - cracking in all but the most severe cases. It is important to note, this was not a structural engineering survey nor was any specialized testing done of any sub-slab plumbing systems during this limited visual inspection, as these are specialized processes requiring excavation. In the event that structural movement is noted, client is advised to consult with a Structural Engineer who can isolate and identify causes, and determine what corrective steps, if any, should be considered to either correct and/or stop structural movement. B. Grading and Drainage - Comments: Note: Any area where the ground or grade does not slope away from the structure is to be considered an area of improper drainage. Six inches per 10 feet is the proper slope, according to current standards.. Improper drainage from foundation - Grade slopes toward the structure Erosion or ponding next to foundation/driveway Gutters draining too close to the structure Run off intrusion into crawl space Trees/heavy foliage too close to the structure Planter(s) adjoining the structure retain water next to the foundation Level lot, does not facilitate proper drainage Inadequate grading clearance to exterior wall surface Leaves/debris in the gutters and downspouts REI 7-2 (8/09) Page 3 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D C. Roof Covering Materials Type(s) of Roof Covering: Asphalt Shingles Viewed From: Ground - Binnoculars Used Comments: Screens are damaged at the attic vents Roof decking deflection and/or sagging Tree branches are too close to the roof structure Evidence of water ponding on the roof is present Missing/damaged rain caps on gas flue pipes Missing step flashing where a roof intersects at exterior wall Brick chimney not properly flashed and counter-flashed Roofing covering installed over older roof covering Torn, damaged, perforated or missing shingles are present A Professional Roofing Company should be consulted for further evaluation and to provide suggestions as to what if any corrective actions should be taken. D. Roof Structure and Attic Viewed From: Entered the Attic Approximate Average Depth of Insulation: 6 to 8 inches of blown-in Approximate Average Thickness of Vertical Insulation: N/A Comments: Insufficient attic ventilation Damaged and/or missing roof sheathing Evidence of previous moisture penetration is present Inadequate roof support and/or failed members Damaged and/or missing vent screens Damaged access ladder REI 7-2 (8/09) Page 4 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D E. Walls (Interior and Exterior) - Comments: Interior Walls: Freshly Painted Evidence of previous water penetration - Water stains are present on walls Signs of Structural Settling - Cracks are present in the sheet rock walls at: By using a thermal imaging camera, evidence of moister penetration is present and can be seen in East wall of the upstairs East bedroom closet. The moister is from condensation forming on the A/C freon lines inside the wall cavity and penetrating into the sheet rock and framing. The insulation on the freon lines may be damaged. The moister was confirmed with a moister meter. (see picture below) REI 7-2 (8/09) Page 5 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D By using a thermal imaging camera, heat energy loss from missing or thin insulation is present at the North interior wall can be seen on each side of the stairs in the upstairs room above the garage. (see picture below) Exterior Walls: Type(s): Brick Vinyl Stone Metal Wood Asbestos Stucco Cement Board Other: Trim boards are water damaged at several areas Mortar is separated or missing in some areas Caulking/sealant is separated or missing in some areas Some cracks at the brick Wood siding is water damaged in some areas Siding shingles are cracked, loose or missing Some siding fasteners are backing out Weep holes not open and/or improper spacing Flashing missing and/or incorrectly installed One or more areas were obstructed foliage and other items By using a thermal imaging camera, missing or thin insulation is present under the windows in the room above the garage. (see picture below) REI 7-2 (8/09) Page 6 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D F. Ceilings and Floors - Comments: Ceilings appear freshly painted Signs of previous water penetration is present - Water stains are present on the ceilings at: Signs of structural settling - Ceiling cracks are present Signs of structural settling - Floor cracks are present G. Doors (Interior and Exterior) - Comments: Interior Doors Damaged doors at: Doors do not latch properly at: Doors loose on hinges at: Doors rub, stick or hit frames at: Deficient doorknobs and/or locks are present at: Closet door do not slide properly or are off the rail at: The ball latch hardware is not installed at the Master bedroom closet door. Exterior Doors Safety glass not present at: Sliding glass door slides poorly or improperly installed at: Sliding screen door is missing/or damaged at: Sliding glass doors do not latch/lock properly at: Doors do not latch properly Doors rub, stick or hit frames at: Deficient doorknobs and/or locks are present: Deadbolt locks do not extend properly into the door frame at: Door weather seal damaged at: The bottom flush bolt does not fully disengage at the inactive door of the North entrance. Garage Doors Type of Door(s): Metal Garage door not present Doors panels are damaged Tension springs are not safely secured Fasteners/hardware is loose Wood Fiberglass H. Windows - Comments: Some windows are difficult to open or close Some glass panes are loose, damaged or missing Some window lift supports are loose, damaged or missing Some window/door screens are damaged or missing Absence of safety glass Window sill height exceeds 44" egress Windows in sleeping areas are of inadequate size for egress Thermal pane window seals have failed, moisture has enter between the glass panes at: Inspection of the windows was limited due to concealment behind furniture and stored items REI 7-2 (8/09) Page 7 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D Burglar bars do not provide for adequate emergency egress Window glazing is damaged and/or missing I. Stairways (Interior and Exterior) - Comments: Int. Ext. The railing at the top of the East stairs is loose. Vertical railing spacing is grater than 4" Landing Undersized or Missing Improper dimensions of stair raisers Improper dimensions of stair treads Hand railing is loose/missing Hand railing is not terminated properly Hand railing not at proper height J. Fireplace/Chimney - Comments: Type of Fireplace: Factory Masonry Wood burning fireplace Not a wood burning fireplace Damper does not operate or missing Hairline cracks are present in the firebox Brick mortar is loose or missing in the firebox or chimney Hearth extension inadequate in size or material Creosote build up in firebox or flue K. Porches, Balconies, Decks, and Carports - Comments: Vertical spindles or rails greater than 4" spacing Deck is not properly attached to main structure Guardrail missing if > 30" from grade Guardrail is not of proper height (36" minimum) Deck boards are loose or damaged Deck board fastener are backing out L. Other - Comments: Sidewalks and Walkways: Sidewalk(s) distorted or damaged Sidewalk(s) do not have control joints Sidewalk(s) are above grade and blocking water flow Sidewalk(s) are spalded/pitted Driveway: Driveway is cracked and deflected Retaining Wall: Retaining wall not present REI 7-2 (8/09) Page 8 of 19 Free Standing Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D Type: Block Other: Stone Railroad Tie Poured Concrete Gabion Landscape Timber Comments: Timbers/Ties are rotting Wall(s) buckling or bowing "Dead Men" not installed Concrete walls are cracked II. ELECTRICAL SYSTEMS A. Service Entrance and Panels - Comments: Overhead Service Underground Service Service line is loose/or pulled away from the house Service line is less than 10 feet above the ground Main Disconnect Panel Type of Wire: Copper Panel is not labeled properly Grounding electrode is not secure to rod Ground wire/rod could not be verified One or more knockouts are missing Panel does not have a main disconnect Incorrect size of wire on breakers Sub Panels Type of Wire: Copper Location: East side of house, Garage and Barn Panels are not labeled properly Not properly grounded or bonded Grounds and neutrals on same bus bar Incorrect size wire on breakers Ground and neutral wires are attached to the same bus bar (typical of older installations) Incorrect size of breakers is in use for the A/C condensing units # 1 and3 (see the following note) A/C condensing unit #1: Specifies max amp breaker of 25 and a 30 amp breaker is in use A/C condensing unit #2: Specifies max amp breaker of 50 and a 40 amp breaker is in use A/C condensing unit #3: Specifies max amp breaker of 40 and a 60 amp breaker is in use REI 7-2 (8/09) Page 9 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D One breakers in the sub panel box located in the barn were observed to be double lugged (two wires under a single lug). Double lugging may not be as firm as single tapping and there may not be sufficient surface contact which can lead to circuit overloading. The breakers in place are not listed or labeled for this type of installation. This condition should be further evaluated and corrected as necessary. (see picture below) It is recommended that a State Licensed Electrician further evaluate and service the electrical system. B. Branch Circuits, Connected Devices, and Fixtures Type of Wiring: Copper Comments: Outlet and Switches Loose, damaged, missing outlet covers at: Loose, damaged, missing switch covers at: Test indicate open circuit, no power to outlets(s) at: Concealed connections of copper and aluminum wires and electrical components were not inspected. Most of the outlets are not grounded or are not three prong, grounded type. ( typical in older homes ) Ground Fault Circuit Interrupt (GFCI) Safety Protection Kitchen: Yes No N/A - According to current standards, all outlets that serve a kitchen counter top are required to be GFCI protected. Bathrooms: Yes No N/A - According to current standards, all bathroom outlets are required to be GFCI protected. Exterior: Yes No N/A - According to current standards, all exterior outlets are required to be GFCI protected. Garage: Yes No N/A - According to current standards, garage outlets are required to be GFCI protected. Wet Bar: Yes No N/A Pool/Spa: Yes No N/A A/C Unit: Yes No N/A Hydro-Therapy Bathtub: Yes No N/A No GFCI protection at one or more location. This is considered a recognized safety hazard. Per the TREC Standards of Practice, I am required to note this as a deficiency. GFCI circuit not inspected at: Arc Fault Circuit Interrupt (AFCI) Safety Protection REI 7-2 (8/09) Page 10 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D AFCI protection is not present throughout the house as required by current standards. Per TREC Standards of Practice, I am required to note this as a deficiency. Fixtures Ceiling fans wobble or vibrate Light fixtures and/or bulbs do not function Light fixture covers are damaged/missing Smoke and Fire Alarms Smoke alarms are not present in each sleeping area Smoke alarms are not present at the top and bottom of the East stairs No smoke alarm in hallway Smoke alarms are not installed Smoke alarm did not function Smoke alarms are not interconnected Smoke alarms are not hardwired to the electrical system Other Electrical System Components It is recommended that a State Licensed Electrician further evaluate and service the electrical system. III. HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS A. Heating Equipment Type of System: Central Energy Source: Electric - Both Upstairs, Dual Fuel-Downstairs The dual fuel system is a heat pump and LP gas furnace. The LP gas furnace does not operate unless it is 37 degrees F. or lower outside. The heat pump does not have auxiliary or emergency heat modes. Comments: No gas cutoff valve installed Blower/filter door safety shut-off switch broken or missing Blower fan assembly is dirty or vibrating Inadequate ventilation for combustion air Rust at the burners and/or burner compartment Evidence of improper flame (impingment, uplifting, color) Gas leak detected Flue is in contact with combustibles Flue pipe is loose or not properly connected to the unit Return air filters need cleaning and/or replacement Recommend cleaning, servicing, and further evaluation by a state licensed HVAC professional REI 7-2 (8/09) Page 11 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D B. Cooling Equipment Type of System: Central - Air Conditioner Comments: The temperature differential for Units # 1 and 2 is not within range of 15-20 degrees. A temperature differential that is not within this range may not be operating properly. Serving and further evaluation of the cooling equipment by a State Licensed HVAC Professional is recommended. Unit #1: Upstairs bedrooms Supply Air Temp: 63 °F Return Air Temp: 74 °F Temp. Differential: 11 °F Unit #2: Downstairs Supply Air Temp: 62 °F Return Air Temp: 74 °F Temp. Differential: 14 °F The temperature differential for the cooling equipment # 3 is within a range of 15 and 20 degrees. Therefore, the cooling equipment appears to be operating properly. Unit #3: Room above Garage Supply Air Temp: 57 °F Return Air Temp: 73 °F Temp. Differential: 16 °F Freon lines are not properly insulated at: Condenser Evaporative coil In Attic Condenser unit coil fins damaged Condenser unit coil fins are dirty Condenser airflow restricted No electric disconnect within sight of unit Primary condensate line not insulated in attic Condensate line termination point was not determined Noticeable vibration of blower fan or condensing fan Condensation line terminates too close to structure Return air filter needs cleaning and/or replacement Recommend cleaning, servicing, and further evaluation by a state licensed HVAC professional C. Duct System, Chases, and Vents - Comments: Type of Ducting: Flex Ducting There is not central airflow supplied to the room addition(s) and/or garage conversion Ducting is kinked or restricted affecting airflow Some ducting moisture barrier is damaged, missing and/or deteriorated REI 7-2 (8/09) Page 12 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D IV.PLUMBING SYSTEM A. Water Supply System and Fixtures Location of water meter: Near North Gate Entrance (inside fence) Location of main water supply valve: North side of house Static water pressure reading: 60 to 70 PSI Comments: Water Source: Public Sewer Type: Private Sinks Finish on sink is damaged Overflow not working Hot and cold water reversed No shut off valves under sink Vegetable sprayer inoperable Drain stop inoperable Bathtubs and Showers Caulking or grout missing or damaged Hot and cold water reversed Drain stop inoperable Tile loose and / or missing Shower head is leaking Commodes Seal leaking between tank & bowl Loose at floor mounting Bowl or tank is cracked/damaged Flush mechanism inoperable Tank lid broken or missing Flapper valve is faulty Washing Machine Connections Washing machine is connected at this time - faucets, drains not tested for proper operation Leakage at plumbing connections Exterior Plumbing Exterior hose bibs do not have back-flow prevention Faucet handles are loose, damaged or missing Leakage present at: B. Drains, Wastes, and Vents - Comments: REI 7-2 (8/09) Page 13 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D C. Water Heating Equipment Unit # 1 Location: Garage closet Energy Source: Electric Capacity: 55 Gallons Approximate Age: 10 Years Hot water temperature is 118 degrees F at the kitchen sink. Unit # 2 Location: Closet under stairs Energy Source: Electric Capacity: 55 Gallons Approximate Age: 10 Years Hot water temperature is 134 degrees F at the Master bathroom sink. Comments: The water heater is not in operation at the time of inspection. Hot water temperature was not checked, inspection is limited. Gas leak detected around unit Missing or inoperable cold water shut off Unit is not properly vented for combustion air Flue pipe is loose, damaged or poorly connected Corrosion and signs of an intermittent leak at plumbing connections is present at Unit #1.(see picture below) Unit is located in the garage or adjacent area and is not elevated so that it's ignition source is 18" above the floor. A drain pan is not installed under the unit, property damage may occur if unit were to leak. Water heater Temperature and Pressure Relief Valve T/P valve inspected/ verified, but NOT TESTED Drain line is not plumbed to the exterior Drain line runs uphill at some point It is recommended that a state licensed plumber further evaluate the water heating equipment. D. Hydro-Massage Therapy Equipment - Comments: Access panel is inaccessible Electrical motor not bonded REI 7-2 (8/09) Page 14 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D The presence of active leaks Vacuum switch does not operate Inoperative unit(s) and controls Lack of ground fault circuit interrupter, inaccessible pump(s) or motor(s) V. APPLIANCES A. Dishwasher - Comments: Unit leaking Unit hardwired (should be a plug-in device) No anti-siphon loop at the drain line Soap dispenser not functioning properly Unit is not properly secured to cabinet Rust present in interior of unit Door seal is damaged or leaking Deficiency in rack, rollers or spray arm B. Food Waste Disposer - Comments: Unit leaking Excessive vibration Splash guard is damaged Unit is hardwired (should be a plug-in device) Electrical cord is not properly secured to the unit. A clamp or bushing is not installed. C. Range Exhaust Vent - Comments: Filter is dirty/greasy Light not functional Light lens missing/damaged Fan/Motor assembly vibrates or is noisy Control knobs / switches are defective or missing Fan/blower does not function D. Ranges, Cooktops, and Ovens - Comments: Range Type: Electric Gas Control knobs are loose and/or missing Burners do not operate Inadequate clearance from combustibles Absence of anti-tilt device Gas leaks were detected around unit Improper or absence of gas shut off valve Improper materials used for gas connections Deficiencies in the operation of the gas flame Oven(s): Unit #1: Electric Gas Tested at 350°F, Variance noted: 353 Unit #2: Electric Gas Tested at 350°F, Variance noted: 336 Control knobs are loose and/or missing REI 7-2 (8/09) Page 15 of 19 °F (max 25°F) °F (max 25°F) Gas leaks were detected around unit Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D Unit is not properly secured Door seal is damaged or leaking Inadequate clearance from combustibles Interior light does not operate Deficiencies in the operation of the gas flame Broiler/heating element does not operate Deficiencies in operation of timer and thermostat Deficiencies in thermostat(s) sensor support E. Microwave Oven - Comments: Deficiencies in door seal/tightness of closure Does not operate by heating a container or water Interior light does not operate Timer does not function F. Trash Compactor - Comments: Key is missing and/or door does not lock Ram does not operate Unit not securely mounted Excessive noise and vibration G. Mechanical Exhaust Vents and Bathroom Heaters - Comments: Units are loose at ceiling and / or wall Heat lamp timer does not work Unit motor and / or fan is noisy Missing covers Unvented gas wall heaters are considered a fire and safety hazard and are not longer recommended to be used. Vent pipes that do not terminate outside the structure H. Garage Door Operator(s) - Comments: Auto reverse does not work - Safety Hazard Switch is installed at improper height Missing safety wire inside door spring Switch is loose or damaged Electronic sensor not installed or improper height Opener is not properly secured No emergency release rope to disable opener Electronic sensor does not operate Door locks or side ropes that have not been removed or disabled I. J. Doorbell and Chimes - Comments: Doorbell did not function Doorbell switch is loose or damaged Dryer Vents - Comments: Dryer vent cover is loose, damaged or missing Dryer vent is not vented to the exterior. VI.OPTIONAL SYSTEMS A. Lawn and Garden Sprinkler Systems - Comments: Operated the sprinkler system on all 4 zones on manual mode. All sprinkler head function normally. B. Private Water Wells (A coliform analysis is recommended.) The well does not have cap on it to provide safety for small children. Water sampling was not performed. REI 7-2 (8/09) Page 16 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D C. Private Sewage Disposal (Septic) Systems Type of System: Aerobic Location of Drain Field: West yard PROXIMITY TO ANY KNOWN WELLS OR UNDERGROUND WATER SUPPLY: Aprox. 100 yards Comments: Visual or olfactory evidence of effluent seepage or flow at the surface of the GROUND Inoperative aerators or dosing pumps DRAIN FIELD NOT FREE OF OBSTRUCTIONS DEFICIENCIES FOUND IN: Visible Components Functional Flow Site Drainage and Clearances Aerobic discharge Performance Opinion: The septic system appears to operating properly. System Information System Type: Dispersal Type: Conventional Aerobic Gravity Drain Field Low Pressure Dosing Above ground Other Approx. Location of Tanks(s) with metal probe: West yard about 10 ft. from the structure Approx. Location of Drain field/Dispersal: West yard at three sprinkler heads Number of Bathrooms: 3 Bathrooms Age of system (if known) : 10 Years Gray water discharging to: Septic system The tank lids are buried under ground and were not exposed by digging. Tank 1 access: visible and accessible NOT visible or accessible Tank 2 access: Tank 3 access: visible and accessible visible and accessible NOT visible or accessible NOT visible or accessible N/A Notice: All septic tanks must be pumped on a regular basis to operate as intended and to prevent premature failure of the system. Pumping frequency typically ranges from every 3 to 5 years depending upon several factors. (Factors may include: tank size, number of household occupants, and other system usage) It is recommended to have tanks pumped during a real estate transaction. Your pumper should be able to view the tank interior for structural cracks or other visible damage that was not visible to your inspector. You are advised to consult with your pumper to insure they can perform this task and report issues to you as necessary. An aerobic type of system should be under a maintenance contract that would inspect the system 3 times per year. It is suggested to inquire if it is currently under contract, when that contract expires, and who performs the service. REI 7-2 (8/09) Page 17 of 19 Report Identification: Sample Report 2, 1234 Paradise Lane, Somewhere, TX I=Inspected NI=Not Inspected NP=Not Present D=Deficient I NI NP D A system cannot be properly inspected if the dwelling has been vacant for more than two weeks such has the case with this home. Without regular or consistent water flow, the disposal area dries out, making problem symptoms difficult to identify and proper inspection difficult if not impossible. A change in daily water flow, occupancy and/or heavy rainfall will create saturated soil conditions which may cause system failure. REI 7-2 (8/09) Page 18 of 19 10-27-08 APPROVED BY THE TEXAS REAL ESTATE COMMISSION (TREC) P.O. BOX 12188, AUSTIN, TX 78711-2188 TEXAS REAL ESTATE CONSUMER NOTICE CONCERNING HAZARDS OR DEFICIENCIES Each year, Texans sustain property damage and are injured by accidents in the home. While some accidents may not be avoidable, many other accidents, injuries, and deaths may be avoided through the identification and repair of certain hazardous conditions. Examples of such hazards include: improperly installed or missing ground fault circuit protection (GFCI) devices for electrical receptacles in garages, bathrooms, kitchens, and exterior areas; improperly installed or missing arc fault protection (AFCI) devices for electrical receptacles in family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreations rooms, closets, hallways, or similar rooms or areas; ordinary glass in locations where modern construction techniques call for safety glass; the lack of fire safety features such as smoke alarms, fire-rated doors in certain locations, and functional emergency escape and rescue openings in bedrooms; excessive spacing between balusters on stairways and porches; improperly installed appliances; improperly installed or defective safety devices; and lack of electrical bonding and grounding. To ensure that consumers are informed of hazards such as these, the Texas Real Estate Commission (TREC) has adopted Standards of Practice requiring licensed inspectors to report these conditions as “Deficient” when performing an inspection for a buyer or seller, if they can be reasonably determined. These conditions may not have violated building codes or common practices at the time of the construction of the home, or they may have been “grandfathered” because they were present prior to the adoption of codes prohibiting such conditions. While the TREC Standards of Practice do not require inspectors to perform a code compliance inspection, TREC considers the potential for injury or property loss from the hazards addressed in the Standards of Practice to be significant enough to warrant this notice. Contract forms developed by TREC for use by its real estate licensees also inform the buyer of the right to have the home inspected and can provide an option clause permitting the buyer to terminate the contract within a specified time. Neither the Standards of Practice nor the TREC contract forms requires a seller to remedy conditions revealed by an inspection. The decision to correct a hazard or any deficiency identified in an inspection report is left to the parties to the contract for the sale or purchase of the home. This form has been approved by the Texas Real Estate Commission for voluntary use by its licensees. Copies of TREC rules governing real estate brokers, salesperson and real estate inspectors are available at nominal cost from TREC. Texas Real Estate Commission, P.O. Box 12188, Austin, TX 78711-2188, 1-800-250-8732 or (512) 459-6544 (http://www.trec.state.tx.us) TREC Form No. OP-I This form is available on the TREC website at www.trec.state.tx.us
© Copyright 2024