Bexter Home Inspections Inc. 13073 SE 26th St. D102 Bellevue, WA 98005 License No. 1078 206-883-8599 Inspection Report 123 Sample Loop Drive Seattle, WA 98XXX Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 1 of 23 Sample Inspection Report.inspx Table of Contents Definitions 2 General Information 2 Lots and Grounds 3 Exterior 4 Roof 5 Garage/Carport 7 Electrical 8 Structure 9 Attic 9 Basement 10 Crawl Space 11 Heating System 11 Plumbing 12 Bathroom 12 Kitchen 14 Bedroom 15 Living Space 16 Laundry Room/Area 17 Summary 18 Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 2 of 23 Sample Inspection Report.inspx Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection A Acceptable Functional with no obvious signs of defect. NP Not Present Item not present or not found. NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. M Marginal Item is not fully functional and requires repair or servicing. D Defective Item needs immediate repair or replacement. It is unable to perform its intended function. General Information Property Information Property Address 123 Sample Loop Drive City Seattle State WA Zip 98XXX Contact Name John Smith Client Information Client Name Client Address Same as above City State Zip Phone Fax Inspection Company Inspector Name Rebecca Willkens Company Name Bexter Home Inspections Inc. Address 13073 SE 26th St. D102 City Bellevue State WA Zip 98005 Phone 206-883-8599 E-Mail [email protected] Conditions Others Present Home Owner Property Occupied Occupied Estimated Age 66 yrs - built in 1947 Entrance Faces East Inspection Date 11/22/2013 Start Time 10AM End Time 2PM Electric On Yes No Not Applicable Gas/Oil On Yes No Not Applicable Water On Yes No Not Applicable Temperature 45 deg F Weather Sunny Soil Conditions Damp Space Below Grade Basement, Crawl Space Building Type Single family Garage Attached Sewage Disposal Septic How Verified King Co. Assessor Water Source Public Utility How Verified King Co. Assessor Additions/Modifications None Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 3 of 23 Sample Inspection Report.inspx General Information (Continued) Permits Obtained N/A How Verified Owner Lots and Grounds A NP NI M D 1. 2. 3. Driveway: Asphalt Walks: Concrete Stairway adjacent to entry Steps/Stoops: Concrete -lacks a handrail--poses a safety hazard. 4. Recommend wood seal at least every Porch: Wood -two years--especially on horizontal surfaces in the PNW. 5. 6. Grading: Moderate slope Swale: Pooling due to improper drainage -pipe along driveway. 7. Vegetation and soil Vegetation: Shrubs/Weeds -should be kept at least 8" from the exterior to minimize entry points for wood destroying insects and moisture. 8. Window Wells: Dryer vent in E. well should be cleaned on a regular basis to for optimal safety and ventilation. 9. Retaining Walls: Stone, Concrete Broken Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 4 of 23 Sample Inspection Report.inspx Lots and Grounds (Continued) 10. Section of fence broken. Handle/latch broken at S. Fences: Wood -gate. Exposed wood in the PNW requires periodic surface treatment -moss removal / wood stain /water seal -- for optimal life expectancy. Exterior A NP NI M D East Exterior Surface Damage @ garage door. Vinyl siding and soffits 1. Type: Vinyl siding -dirty on S and W sides of house. Cable hanging unattached on S side. Recommend filling / blocking any large holes to prevent moisture / critter intrusion. 2. Trim: Wood 3. Paint peeling at many locations of wood trim Fascia: Wood, Vinyl -and wood fascia. Soffits: Vinyl Inoperative Door Bell: Hard wired -Entry Doors: Solid painted wood, storm door. 4. 5. 6. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 5 of 23 Sample Inspection Report.inspx Exterior (Continued) 7. 8. 9. 10. 11. Patio Door: Wood and glass Windows: Vinyl casement, Vinyl slider, Aluminum slider Window Screens: Basement Windows: Exterior Lighting: Surface mounted lamps front and rear -Fixture cover missing @ side door light fixture. Flood lights on motion sensors--not tested. 12. All but one lack a vacuum breaker to prevent Hose Bibs: Ball -backflow into public water system. Static water pressure measured 90 psi. High water pressure (over 80 psi) can damage plumbing fixtures and appliances. Recommend evaluation / installation of a pressure regulator by a licensed plumber. Roof A NP NI M D Main Roof Surface 1. Method of Inspection: On roof 2. Unable to Inspect: 3. Material: Asphalt shingle 4. Type: Gable 5. Approximate Age: 1-5 yrs 6. Flashing: Aluminum Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 6 of 23 Sample Inspection Report.inspx Roof (Continued) 7. 8. 9. Valleys: Asphalt shingle Plumbing Vents: PVC, Cast Iron Electrical Mast: Surface mount -at masthead. 10. Gutters: Aluminum -- 11. 12. West Chimney 13. 14. Downspouts: Aluminum Leader/Extension: 15. Chimney Flashing: Aluminum -installed. Chimney: Brick Flue/Flue Cap: Mortar -cap present. Damage to vinyl siding Need cleaning Unlined chimney flue, no rain Recently replaced / Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 7 of 23 Sample Inspection Report.inspx Garage/Carport A NP NI M D Attached Garage 1. Type of Structure: Attached Car Spaces: 2 Door panels have water damage. 2. Garage Doors: Wood -- 3. 4. 5. 6. 7. 8. 9. 10. Door Operation: Mechanized Motor is unusually loud when operating. Door Opener: Genie -Roof: Asphalt shingle Roof Structure: 2x4 Truss Ceiling: Exposed framing Walls: Exposed framing Floor/Foundation: Poured concrete Non-GFCI circuits, missing junction box and Electrical: 110 VAC -outlet cover plates. A licensed electrician is recommended to evaluate and estimate repairs. 11. 12. 13. 14. Smoke Detector: Recommend installation of a smoke detector in garage. Heating: Windows: Aluminum slider Sump Pump Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 8 of 23 Sample Inspection Report.inspx Electrical A NP NI M D 1. Service Size Amps: 200 Volts: 110-120 VAC 2. Service: Aluminum 3. 120 VAC Branch Circuits: Aluminum 4. Aluminum Wiring: 5. Conductor Type: Romex 6. Ground: Did not locate. None 7. Smoke Detectors: None located throught house. At a minimum -located throughout house. Recommend installation of one in attic, garage, basement and main floor. Recessed in wall of main floor W bedroom Electric Panel Did not remove panel cover 8. Manufacturer: Federal Pacific/Stab Lok -at owner's request. Federal Pacific panel breakers have a history of not tripping when circuit overloading exists posing a fire / safety hazard. Recommend existing panel be replaced by a licensed electrical contractor. GENERAL NOTE: There are ungrounded 2 and 3-prong outlets throughout the house. Ungrounded 2-prong outlets are acceptable (because they don't represent themselves as grounded) and or can function as "grounded" with the use of an operational GFCI outlet upstream on their circuit. GFCI outlets (with a reset button) should be grounded, operational and trip when tested. Recommend smoke detectors on each floor and in the garage, GFCI circuit protection in kitchen and bathrooms and service panel/breaker replacement--all by a licensed electrical contractor. 9. Maximum Capacity: 200 Amps 10. Main Breaker Size: 200 Amps 11. Breakers: See note about Stab Lok panel and breakers. 12. Is the panel bonded? Yes No Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 9 of 23 Sample Inspection Report.inspx Structure A NP NI M D 1. 2. 3. 4. 5. Structure Type: Wood frame Foundation: Block Differential Movement: No movement or displacement noted Bearing Walls: Frame Moisture damage to floor joists observed in Joists/Trusses: 2x8 -crawl space. 6. 7. 8. Floor/Slab: Poured slab Stairs/Handrails: Wood stairs with wood handrails Subfloor: Attic A NP NI M D Northeast Attic 1. Method of Inspection: In the attic 2. Roof Framing: 2x4 Rafter 3. Sheathing: Dimensional wood 4. Ventilation: Gable, roof and soffit vents 5. 6. Insulation: Fiberglass, Batts Recommend additional insulation Insulation Depth: 6" -be installed. 7. Wiring/Lighting: 110 VAC -boxes. Recommend cover plates on all open junction Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 10 of 23 Sample Inspection Report.inspx Attic (Continued) Wiring/Lighting: (continued) 8. Moisture Penetration: Evidence of past moisture penetration. Roof has recently been replaced. No moisture present at time of inspection. Bathroom Fan Venting: Electric fan 9. Basement A NP NI M D Basement 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Ceiling: Paint Walls: Paint Floor: Carpet -- Moderate stains and tears. Doors: Solid wood, Solid wood Windows: Aluminum slider Electrical: 3-hole outlets not grounded Smoke Detector: HVAC Source: Heating system register Vapor Barrier: Insulation: Ventilation: Moisture Location: Basement Stairs/Railings: Wood stairs with wood handrails Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 11 of 23 Sample Inspection Report.inspx Crawl Space A NP NI M D North Crawl Space 1. Method of Inspection: In the crawl space 2. Access: Wood door 3. Moisture Penetration: No moisture present at time of inspection 4. Moisture Location: 5. Ventilation: Vents 6. Insulation: 7. Vapor Barrier: Complete and recently installed. 6-mil Visqueen Heating System A NP NI M D Basement Heating System 1. Heating System Operation: Appears functional Thermo Pride 2. Manufacturer: 3. Model Number: OL5-85FDA Serial Number: AN211512 4. Type: Forced air Capacity: 5. Area Served: Whole building Approximate Age: 6. Fuel Type: Oil 7. Heat Exchanger: 1 Burner 8. Unable to Inspect: 80% Last noted 9. Blower Fan/Filter: Belt drive with disposable filter -service in 2010. Recommend service every two years. 10. 11. 12. 13. 14. 15. Distribution: Metal duct Circulator: N/A Draft Control: Manual Flue Pipe: Double wall Controls: Limit switch Thermostats: Whole-house. Located in LR. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 12 of 23 Sample Inspection Report.inspx Heating System (Continued) 16. Fuel Tank: Oil tank 17. Tank Location: Side yard 18. Suspected Asbestos: No Plumbing A NP NI M D 1. 2. Service Line: Galvanized Multiple shut-offs Main Water Shutoff: Front of house, Basement -observed in basement and garage. Recommend labeling for emergencies and future owners. 3. Water Lines: Galvanized and copper 4. Drain Pipes: ABS 5. Service Caps: 6. Vent Pipes: ABS Basement Water Heater 7. Water Heater Operation: Functional at time of inspection Rheem 8. Manufacturer: 9. Model Number: 83XR66-2 Serial Number: RH-0911R08830 10. Type: Electric Capacity: 65 Gal. 11. Approximate Age: 2yrs Area Served: Whole building 12. TPRV and Drain Tube: Copper Bathroom A NP NI M D 1st floor main Bathroom 1. Ceiling: Paint, Tile 2. Walls: Paint and tile Missing grout, repair as required. 3. Floor: Tile -- Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 13 of 23 Sample Inspection Report.inspx Bathroom (Continued) 4. Doors: Solid wood -- 5. Outlet is ungrounded and not GFCI protected. It Electrical: 110 VAC -is also loose from the wall. Recommend installation of an operational GFCI outlet by a licensed electrical contractor. Counter/Cabinet: Composite and wood Cold water shut off Sink/Basin: Molded single bowl -handle is missing. 6. 7. Damaged at lock mechanism. 8. Faucets/Traps: 9. Tub/Surround: Porcelain tub and ceramic tile surround 10. Toilets: American Standard 11. HVAC Source: Heating system register 12. Ventilation: Electric ventilation fan Basement Bathroom 13. Ceiling: Paint 14. Walls: Paint 15. Floor: Tile 16. Doors: Hollow wood 17. Windows: Aluminum slider No power to GFCI 18. Electrical: 110 VAC GFCI -outlet--unable to reset / trip. Recommend evaluation / replacement by a licensed electrical contractor. 19. 20. 21. Counter/Cabinet: Tile. Sink/Basin: Porcelain Large gaps around sink Faucets/Traps: Not visible -plumbing penetrations under sink. Recommend filling with foam / drywall patch to restrict critter and air movement through wall. 22. 23. 24. Shower/Surround: Fiberglass pan and ceramic tile surround Toilets: HVAC Source: Heating system register Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 14 of 23 Sample Inspection Report.inspx Bathroom (Continued) 25. Ventilation: Electric ventilation fan and window Kitchen A NP NI M D Main Floor Kitchen 1. 2. 3. 4. Air Gap Present? 5. 6. 7. 8. 9. Cooking Appliances: Jenn-Air Ventilator: Dishwasher: Kitchenaid Yes No Refrigerator: Maytag Microwave: Daewoo, LG Sink: Porcelain Electrical: 110 VAC outlets and lighting circuits -GFCI marked outlets are not GFCI protected--did not trip when tested. Recommend evaluation by a licensed electrical contractor. Plumbing/Fixtures: Chrome -copper and flex line. Combination galvanized, 10. Counter Tops: Formica, Tile -near sink. 11. 12. Cabinets: Wood Ceiling: Paint -- Minor damage observed Evidence of possible water damage. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 15 of 23 Sample Inspection Report.inspx Kitchen (Continued) 13. Walls: Wallpaper -and discolored. 14. 15. Floor: Vinyl floor covering Door trim unfinished. Doors: Solid wood -- 16. 17. Windows: Aluminum slider HVAC Source: Heating system register Some areas of paper are peeling Bedroom A NP NI M D Main Floor West Bedroom 1. Closet: Single small 2. Ceiling: Texture paint Trim paint is not complete. 3. Walls: Paint -- 4. Floor: Painted Hardwood -- 5. Doors: Solid wood -- 6. 7. 8. Windows: Aluminum slider Electrical: 110 VAC HVAC Source: Heating system register Worn wood floor finish. Needs paint. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 16 of 23 Sample Inspection Report.inspx Bedroom (Continued) 9. Smoke Detector: Main Floor East / Office Bedroom 10. Closet: Single small 11. Ceiling: Paint 12. Walls: Textured paint 13. Floor: Carpet 14. Doors: Solid wood 15. Windows: Aluminum slider 16. Electrical: 110 VAC 17. HVAC Source: Heating system register 18. Smoke Detector: Basement Bedroom 19. Closet: Single small Evidence of past or present water 20. Ceiling: Paint -staining. 21. 22. 23. 24. 25. 26. 27. Walls: Paint Floor: Carpet Doors: Hollow wood Windows: Vinyl slider Electrical: 110 VAC HVAC Source: Heating system register Smoke Detector: Living Space A NP NI M D Living Room Living 1. 2. 3. 4. 5. 6. 7. 8. Living Space 9. Space Ceiling: Paint Walls: Paint Minor damage/wear at seams. Floor: engineered hardwood -Doors: Painted Solid Wood, Glass-Aluminum Storm Door w/ Tempered Glass Windows: Vinyl casement, Vinyl slider Electrical: 110 VAC outlets and lighting circuits HVAC Source: Heating system register Smoke Detector: None present throughout main floor. Ceiling: Paint Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 17 of 23 Sample Inspection Report.inspx Living Space (Continued) 10. Walls: Paint -- 11. Floor: Wood Laminate -- 12. 13. 14. 15. 16. Doors: Solid wood, Glass Storm Door Windows: Vinyl casement, Vinyl casement Ungrounded. Electrical: 110 VAC -HVAC Source: Heating system register Smoke Detector: Trim needs paint. Some damage visible at seams. Laundry Room/Area A NP NI M D Basement Laundry Room/Area 1. Ceiling: Exposed framing 2. Walls: Exposed framing 3. Floor: Concrete 4. Windows: Aluminum slider 5. Electrical: Ungrounded outlets 6. Smoke Detector: 7. Washer Hose Bib: 8. Washer and Dryer Electrical: 9. Dryer Vent: Rigid metal 10. Washer Drain: Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 18 of 23 Sample Inspection Report.inspx Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds Stairway adjacent to entry lacks a 1. Steps/Stoops: Concrete -handrail--poses a safety hazard. Recommend wood seal at least every two 2. Porch: Wood -years--especially on horizontal surfaces in the PNW. Vegetation and soil should be kept at 3. Vegetation: Shrubs/Weeds -least 8" from the exterior to minimize entry points for wood destroying insects and moisture. Garage/Carport 4. Attached Garage Garage Doors: Wood -- Door panels have water damage. Non-GFCI circuits, missing junction box and 5. Attached Garage Electrical: 110 VAC -outlet cover plates. A licensed electrician is recommended to evaluate and estimate repairs. Attic 6. Northeast Attic Insulation Depth: 6" -be installed. Recommend additional insulation Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 19 of 23 Sample Inspection Report.inspx Marginal Summary (Continued) 7. Northeast Attic Wiring/Lighting: 110 VAC -boxes. Recommend cover plates on all open junction Basement 8. Basement Floor: Carpet -- Moderate stains and tears. 9. Basement Electrical: 3-hole outlets not grounded Heating System 10. Basement Heating System Blower Fan/Filter: Belt drive with disposable filter -noted service in 2010. Recommend service every two years. Last Bathroom 11. 1st floor main Bathroom Floor: Tile -required. Missing grout, repair as 12. 1st floor main Bathroom Doors: Solid wood -- Damaged at lock mechanism. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 20 of 23 Sample Inspection Report.inspx Marginal Summary (Continued) Kitchen 13. Main Floor Kitchen Counter Tops: Formica, Tile -near sink. 14. Main Floor Kitchen Ceiling: Paint -- Minor damage observed Evidence of possible water damage. Bedroom 15. Main Floor West Bedroom Walls: Paint -- Trim paint is not complete. 16. Main Floor West Bedroom Floor: Painted Hardwood -finish. 17. Main Floor West Bedroom Doors: Solid wood -- 18. Basement Bedroom Ceiling: Paint -staining. Worn wood floor Needs paint. Evidence of past or present water Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 21 of 23 Sample Inspection Report.inspx Marginal Summary (Continued) Living Space 19. Living Space Walls: Paint -- Trim needs paint. 20. Living Space Floor: Wood Laminate -- 21. Living Space Electrical: 110 VAC -- Some damage visible at seams. Ungrounded. Laundry Room/Area 22. Basement Laundry Room/Area Electrical: Ungrounded outlets Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 22 of 23 Sample Inspection Report.inspx Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Lots and Grounds 1. Swale: Pooling due to improper drainage -driveway. Broken pipe along Section of fence broken. Handle/latch broken at S. gate. Exposed 2. Fences: Wood -wood in the PNW requires periodic surface treatment -- moss removal / wood stain /water seal -- for optimal life expectancy. Exterior 3. Door Bell: Hard wired -- Inoperative Electrical 4. Recessed in wall of main floor W bedroom Electric Panel Manufacturer: Federal Pacific/Stab Lok -Did not remove panel cover at owner's request. Federal Pacific panel breakers have a history of not tripping when circuit overloading exists posing a fire / safety hazard. Recommend existing panel be replaced by a licensed electrical contractor. GENERAL NOTE: There are ungrounded 2 and 3-prong outlets throughout the house. Ungrounded 2-prong outlets are acceptable (because they don't represent themselves as grounded) and or can function as "grounded" with the use of an operational GFCI outlet upstream on their circuit. GFCI outlets (with a reset button) should be grounded, operational and trip when tested. Recommend smoke detectors on each floor and in the garage, GFCI circuit protection in kitchen and bathrooms and service panel/breaker replacement--all by a licensed electrical contractor. 5. Recessed in wall of main floor W bedroom Electric Panel Breakers: See note about Stab Lok panel and breakers. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc. Bexter Home Inspections Inc. 08:42 November 30, 2013 Page 23 of 23 Sample Inspection Report.inspx Defective Summary (Continued) Bathroom Outlet is ungrounded and not GFCI 6. 1st floor main Bathroom Electrical: 110 VAC -protected. It is also loose from the wall. Recommend installation of an operational GFCI outlet by a licensed electrical contractor. Cold water shut 7. 1st floor main Bathroom Sink/Basin: Molded single bowl -off handle is missing. No power to GFCI 8. Basement Bathroom Electrical: 110 VAC GFCI -outlet--unable to reset / trip. Recommend evaluation / replacement by a licensed electrical contractor. Kitchen 9. Main Floor Kitchen Electrical: 110 VAC outlets and lighting circuits -GFCI marked outlets are not GFCI protected--did not trip when tested. Recommend evaluation by a licensed electrical contractor. Palm-Tech Inspector, Copyright © 1998-2013, PDmB, Inc.
© Copyright 2024