Albatros2 Zone controller User Manual OEM RVS46.. AVS75.. AVS37.. QAA75.. QAA78.. QAA55.. Edition 3.0 CE1U2353en01a 7 November 2007 Building Technologies HVAC Products 2/32 Siemens Switzerland Ltd HVAC Products User Manual OEM CE1U2353en01a 7 November 2007 Contents 1 Overview of OEM settings ............................................................................... 5 2 The settings in detail...................................................................................... 20 2.1 Operator section ............................................................................................ 20 Operation and display.................................................................................... 20 2.2 Heating circuits .............................................................................................. 20 Mixing valve control ....................................................................................... 20 2.3 Cooling circuit ................................................................................................ 21 Mixing valve control ....................................................................................... 21 2.4 DHW .............................................................................................................. 21 Setpoints........................................................................................................ 21 2.5 Hx pumps ...................................................................................................... 21 Pump Hx........................................................................................................ 21 2.6 Primary controller / system pump .................................................................. 21 Flow temperature setpoint limits.................................................................... 21 Mixing valve control ....................................................................................... 22 2.7 Solar .............................................................................................................. 22 Start function ................................................................................................. 22 2.8 DHW storage tank ......................................................................................... 23 Release ......................................................................................................... 23 Charging control ............................................................................................ 23 Charging time limitation ................................................................................. 24 Discharging protection................................................................................... 24 Overtemperature protection........................................................................... 24 DHW push ..................................................................................................... 25 Mixing valve precontrol.................................................................................. 25 Transfer ......................................................................................................... 26 2.9 Instantaneous DHW heater ........................................................................... 26 Mixing valve control ....................................................................................... 26 2.10 Configuration ................................................................................................. 27 Building and room model............................................................................... 27 Pressure acquisition H1, H2 .......................................................................... 27 Device hours run ........................................................................................... 27 2.11 LPB system ................................................................................................... 28 Error/maintenance/alarms ............................................................................. 28 Action changeover functions ......................................................................... 28 2.12 Faults............................................................................................................. 28 History 1..10 .................................................................................................. 28 2.13 Diagnostics, consumers ................................................................................ 29 Heating circuit 1, heating circuit 2, heating circuit P ...................................... 29 3 Revision history ............................................................................................. 31 3/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Contents CE1U2353en01a 7 November 2007 4/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 1 Overview of OEM settings The table below shows all available settings. However, certain operating lines may be hidden, depending on the type of unit. Time of day and date 1 E Hours / minutes 2 E Day/month 3 E Year 5 F Start of summertime 6 F End of summertime Operator section 20 E Language 25.03 25.10 00:00 01.01 2004 01.01 01.01 O = OEM 23:59 31.12 2099 31.12 31.12 German Unit Max F = Heating engineer Min Function user level Operating line Default value E = Enduser I = Commissioning BZ = Operating line 1) QAA75../78.. only 4) RVS46.543 only Legend hh:mm dd.MM yyyy dd.MM dd.MM - German ¦ … 21 O Display special operation On Off ¦ On 22 F Info Temporarily - Off - Off - Temporarily ¦ Permanently 26 F Operation lock Off ¦ On 27 F Programming lock Off ¦ On 28 I Direct adjustment Save with acknowledgment Automatic storage ¦ Save with acknowledgment 30 O Save basic settings No No ¦ Yes 31 O Activate basic settings No No ¦ Yes 401) I Used as Room unit 1 - Heating circuit 1 - Commonly with HC1 - Commonly with HC1 - Heating circuit 1 - Room unit 1 ¦ Room unit 2 ¦ Room unit P ¦ Operator unit 1 ¦ Operator unit 2 ¦ Operator unit P ¦ Service unit 42 I Assignment device 1 Heating circuit 1 ¦ Heating circuits 1 and 2 ¦ Heating circuits 1 and P ¦ All heating circuits 44 I Operation HC2 Commonly with HC1 ¦ Independently 46 I Operation HCP Commonly with HC1 ¦ Independently 481) I Action occupancy button None ¦ Heating circuit 1 ¦ Heating circuit 2 ¦ Commonly 541) F 70 F Radio 120 I Readjustment room sensor Software version 0.0 - Binding No -3 0 3 99.9 °C - No ¦ Yes 121 I Test mode Off Off ¦ On 5/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 I Room unit 1 Unit Max Min Default value Function user level Operating line 130 - - - - Missing ¦ Ready ¦ No recept’n ¦ Change batt 131 I Room unit 2 Missing ¦ Ready ¦ No recept’n ¦ Change batt 132 I Room unit P - Missing ¦ Ready ¦ No recept’n ¦ Change batt 133 I OutsideSens - - - - Missing ¦ Ready ¦ No recept’n ¦ Change batt 134 I Repeater Missing ¦ Ready ¦ No recept’n ¦ Change batt 135 I Operator unit 1 - Missing ¦ Ready ¦ No recept’n ¦ Change batt 136 I Operator unit 2 - Missing ¦ Ready ¦ No recept’n ¦ Change batt 137 I Operator unit P - - - - No - Mo - Su - Missing ¦ Ready ¦ No recept’n ¦ Change batt 138 I Service unit Missing ¦ Ready ¦ No recept’n ¦ Change batt 140 I Delete all devices No ¦ Yes Time prog heating circuit 1 500 E Preselection Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su 501 502 503 504 505 506 516 E E E E E E E 1. phase on 1. phase off 2. phase on 2. phase off 3. phase on 3. phase off Default values 6:00 22:00 24:00 24:00 24:00 24:00 No 00:00 00:00 00:00 00:00 00:00 00:00 24:00 24:00 24:00 24:00 24:00 24:00 hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm - No ¦ Yes Time prog heating circuit 2 520 E Preselection Mo - Su - Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su 521 522 523 524 525 526 536 E E E E E E E 1. phase on 1. phase off 2. phase on 2. phase off 3. phase on 3. phase off Default values 6:00 22:00 24:00 24:00 24:00 24:00 No 00:00 00:00 00:00 00:00 00:00 00:00 24:00 24:00 24:00 24:00 24:00 24:00 hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm - No ¦ Yes Time program 3/HCP 540 E Preselection Mo - Su - Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su 541 542 543 544 545 546 E E E E E E 1. phase on 1. phase off 2. phase on 2. phase off 3. phase on 3. phase off 6:00 22:00 24:00 24:00 24:00 24:00 00:00 00:00 00:00 00:00 00:00 00:00 24:00 24:00 24:00 24:00 24:00 24:00 hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm 6/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 E Default values Unit Max Min Default value Function user level Operating line 556 No - Mo - Su - No ¦ Yes Time program 4/DHW 560 E Preselection Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su 561 562 563 564 565 566 576 E E E E E E E 1. phase on 1. phase off 2. phase on 2. phase off 3. phase on 3. phase off Default values 6:00 22:00 24:00 24:00 24:00 24:00 No 00:00 00:00 00:00 00:00 00:00 00:00 24:00 24:00 24:00 24:00 24:00 24:00 hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm - No ¦ Yes Time program 5 600 E Preselection Mo - Su - Mo - Su ¦ Mo - Fr ¦ Sa - Su ¦ Mo ¦ Tu ¦ We ¦ Th ¦ Fr ¦ Sa ¦Su 601 602 603 604 605 606 616 E E E E E E E 1. phase on 1. phase off 2. phase on 2. phase off 3. phase on 3. phase off Default values 6:00 22:00 24:00 24:00 24:00 24:00 No 00:00 00:00 00:00 00:00 00:00 00:00 24:00 24:00 24:00 24:00 24:00 24:00 hh:mm hh:mm hh:mm hh:mm hh:mm hh:mm - No ¦ Yes Holidays heating circuit 1 641 E Preselection Period 1 - Period 1 ¦ Period 2 ¦ Period 3¦ Period 4¦ Period 5¦ Period 6¦ Period 7¦ Period 8 642 643 648 E E E Start End operating level --.-01.01 --.-01.01 Frost protection 31.12 31.12 dd.MM dd.MM - Frost protection ¦ Reduced Holidays heating circuit 2 651 E Preselection Period 1 - Period 1 ¦ Period 2 ¦ Period 3¦ Period 4¦ Period 5¦ Period 6¦ Period 7¦ Period 8 652 653 658 E E E Start End operating level --.-01.01 --.-01.01 Frost protection 31.12 31.12 dd.MM dd.MM - Frost protection ¦ Reduced Holidays heating circuit P 661 E Preselection Period 1 - Period 1 ¦ Period 2 ¦ Period 3¦ Period 4¦ Period 5¦ Period 6¦ Period 7¦ Period 8 662 663 668 E E E Start End operating level --.-01.01 --.-01.01 Frost protection 31.12 31.12 dd.MM dd.MM - Frost protection ¦ Reduced Heating circuit 1 710 E Comfort cooling setpoint 712 E Reduced setpoint 714 E Frost protection setpoint 20.0 16 10.0 Operating line 712 Operating line 716 Operating line 714 Operating line 710 4 Operating line 712 °C °C °C 7/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 F E F F 730 732 740 741 750 760 770 780 E F I I F F F F Comfort setpoint maximum Heating curve slope Heating curve displacement Heating curve adaption 35.0 1.50 0.0 Off Unit Max Min Default value Function user level Operating line 716 720 721 726 Operating line 710 35 0.10 4.00 -4.5 4.5 °C °C - Off ¦ On Summer/winter heating limit 24-hour heating limit Flow temp setpoint min Flow temp setpoint max Room influence Room temp limitation Boost heating Quick setback 18 −−−/8 -3 − − − / -10 8 8 80 Operating line 740 20 −−−/1 1 − − − / 0.5 5 −−−/0 Down to reduced setpoint 30 10 Operating line 741 95 100 4 20 °C °C °C °C % °C °C - 0 0 −−− -15 On 360 360 10 Operating line 800 min min °C °C - 5 0 3-position 50 °C - 2 120 32 120 Off 20 873 100 873 °C s °C s - 95 °C - Off ¦ Down to reduced setpoint ¦ Down to frost prot setp 790 791 800 801 820 F F F F F Optimum start control max Optimum top control max Reduced setp increase start Reduced setp increase end Overtemp prot pump circuit 830 832 F F Mixing valve boost Actuator type 833 834 835 836 850 F F O O I Switching differential 2-pos Actuator running time Mixing valve Xp Mixing valve Tn Floor curing function 0 0 − − − / -30 -30 Off ¦ On 2-position ¦ 3-position 0 30 1 10 Off ¦ Functional heating ¦ Curing heating ¦ Functional/ curing heating¦ Curing/functional heating ¦ Manually 851 861 I F Floor curing setp manual Excess heat draw 870 F With buffer storage tank 25 0 Always Off ¦ Heating mode ¦ Always Yes - Yes - Protection mode - Automatically - No ¦ Yes 872 F With primary controller / system pump No ¦ Yes 900 F Optg mode changeover None ¦ Protection ¦ Reduced ¦ Comfort ¦ Automatic Cooling circuit 1 901 E Operating mode Off ¦ Automatic 902 907 E E 908 909 912 913 918 919 I I I F F F Comfort cooling setpoint release 24.0 15 24 h/day 40 °C - 20 16 20 24 26 35 35 35 355 100 35 35 °C °C °C h °C °C 24h/day ¦ Time programs HCs ¦ Time program 5 Flow setpoint at OT 25°C Flow setpoint at OT 35°C Cooling limit at OT (outside temperature) Locking period at end of heating Start of summer compensation at OT End of summer compensation at OT 8 8 −−−/8 −−−/8 20 20 8/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 F I I F F F F Summer compensation setpoint increase Flow setpoint min. OT 25°C Flow setpoint min. OT 35°C Room influence Room temp limitation Mixing valve cooling offset Actuator type 940 941 942 943 945 F F O O F Switching differential 2-pos Actuator running time Mixing valve Xp Mixing valve Tn Mixing valve in heating mode Unit Max Min Default value Function user level Operating line 920 923 924 928 932 938 939 4 −−−/1 18 8 18 8 80 −−−/1 0.5 − − − / 0.5 0 0 3-position 10 35 35 100 4 20 °C °C °C % °C °C - 2 120 12 90 Controls 0 30 1 10 20 873 100 873 °C s °C s 60 3 60 2 No − − − / 10 −−−/1 0 −−−/0 600 10 100 10 min °C % °C - 2-position ¦ 3-position Control ¦ Open 946 947 948 950 962 F F F I F Dewpt monitor locking time Flow setpt increase hygro Start flow increase at R.H. Flow temp diff dewpoint With buffer storage tank 963 F With primary controller / system pump No ¦ Yes No - Off - No ¦ Yes 969 I Optg mode changeover None ¦ Off ¦ Automatic Heating circuit 2 1010 E Comfort cooling setpoint 20.0 1012 E Reduced setpoint 16 1014 1016 E F Frost protection setpoint Comfort setpoint maximum 10.0 35.0 1020 1021 1026 E F F Heating curve slope Heating curve displacement Heating curve adaption 1.50 0.0 Off 1030 1032 1040 1041 E F I I Summer/winter heating limit 24-hour heating limit Flow temp setpoint min Flow temp setpoint max 1050 1060 1070 1080 F F F F Room influence Room temp limitation Boost heating Quick setback Operating line 1012 Operating line 1014 4 Operating line 1010 0.10 -4.5 Operating line 1016 °C Operating line 1010 °C Operating line 1012 °C 35 °C 4.00 4.5 °C - −−−/8 − − − / -10 8 Operating line 1040 20 −−−/1 1 − − − / 0.5 5 −−−/0 Down to reduced setpoint 30 10 Operating line 1041 95 °C °C °C °C 100 4 20 % °C °C - 0 0 −−− -15 360 360 10 Operating line 1100 min min °C °C Off ¦ On 18 -3 8 80 Off ¦ Down to reduced setpoint ¦ Down to frost prot setp 1090 1091 1100 1101 F F F F Optimum start control max Optimum top control max Reduced setp increase start Reduced setp increase end 0 0 − − − / -30 -30 9/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 F Overtemp prot pump circuit Unit Max Min Default value Function user level Operating line 1120 On - Off ¦ On 1130 1132 F F Mixing valve boost Actuator type 1133 1134 1135 1136 1150 F F O O F Switching differential 2-pos Actuator running time Mixing valve Xp Mixing valve Tn Floor curing function 5 0 3-position 50 °C - 2 120 32 120 Off 20 873 100 873 °C s °C s - 95 °C - 2-position ¦ 3-position 0 30 1 10 Off ¦ Functional heating ¦ Curing heating ¦ Functional/ curing heating¦ Curing/functional heating ¦ Manually 1151 1161 F F Floor curing setp manual Excess heat draw 1170 F With buffer storage tank 25 0 Always Off ¦ Heating mode ¦ Always Yes - Yes - Protection mode - Automatically - No ¦ Yes 1172 F With primary controller / system pump No ¦ Yes 1200 F Optg mode changeover None ¦ Protection ¦ Reduced ¦ Comfort ¦ Automatic Heating circuit P 1300 E Operating mode Protection ¦ Automatic ¦ Reduced ¦ Comfort 1310 E Comfort cooling setpoint 20.0 1312 E Reduced setpoint 16 1314 1316 E F Frost protection setpoint Comfort setpoint maximum 10.0 35.0 1320 1321 1326 E F F Heating curve slope Heating curve displacement Heating curve adaption 1.50 0.0 Off 1330 1332 1340 1341 E F F F Summer/winter heating limit 24-hour heating limit Flow temp setpoint min Flow temp setpoint max 1350 1360 1370 1380 F F F F Room influence Room temp limitation Boost heating Quick setback 1390 1391 1400 1401 1420 F F F F F Optimum start control max Optimum top control max Reduced setp increase start Reduced setp increase end Overtemp prot pump circuit Operating line 1312 Operating line 1314 4 Operating line 1310 0.10 -4.5 Operating line 1316 °C Operating line 1310 °C Operating line 1312 °C 35 °C 4.00 4.5 °C - −−−/8 − − − / -10 8 Operating line 1340 20 −−−/1 1 − − − / 0.5 5 −−−/0 Down to reduced setpoint 30 10 Operating line 1341 95 °C °C °C °C 100 4 20 % °C °C - 0 0 −−− -15 On 360 360 10 Operating line 1400 min min °C °C - Off ¦ On 18 -3 8 80 Off ¦ Down to reduced setpoint ¦ Down to frost prot setp 0 0 − − − / -30 -30 Off ¦ On 10/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 I Floor curing function Off Unit Max Min Default value Function user level Operating line 1450 - Off ¦ Functional heating ¦ Curing heating ¦ Functional/ curing heating¦ Curing/functional heating ¦ Manually 1451 1455 1456 1457 1461 I F F F F Floor curing setp manual Floor curing setp current Floor curing day current Floor curing days complete Excess heat draw 25 0 0 0 Always 0 0 0 0 95 95 32 32 °C °C - Off ¦ Heating mode ¦ Always 1470 F With buffer storage tank Yes - Yes - Protection mode - No ¦ Yes 1472 F With primary controller / system pump No ¦ Yes 1500 F Optg mode changeover None ¦ Protection ¦ Reduced ¦ Comfort ¦ Automatic DHW 1610 E Nominal setpoint 1612 1614 1620 Reduced setpoint nominal setpoint max release F O I 55 Operating line 1612 40 8 65 8 Time programs HCs BZ 1614 OEM °C Operating line 1610 °C 80 °C - 24h/day ¦ Time programs HCs ¦ Time program 4/DHW 1630 I Charging priority MC shifting, PC absolute - Fixed weekday - Absolute ¦ Shifting ¦ None ¦ MC shifting, PC absolute 1640 F Legionella function Off ¦ Periodically ¦ Fixed weekday 1641 1642 F F Legionella funct periodically Legionella funct weekday 3 1 Monday 7 Days −−− 65 30 On 23:50 95 360 hh:mm °C min - Monday ¦ Tuesday ¦ Wednesday ¦ Thursday ¦ Friday ¦ Saturday ¦ Sunday 1644 1645 1646 16474) F F F F Legionella function time Setpoint of Legionella function Legionella function dwelling time Legionella funct circ pump − − − / 00:00 55 − − − / 10 Off ¦ On 1660 4) F Circulating pump release DHW release - On - Time program 3/HCP ¦ DHW release ¦ Time program 4/DHW¦ Time program 5 16614) F Circulating pump cycling Off ¦ On 16634) F Circulation setpoint Hx pumps 2008 O H1 DHW charging priority 45 8 80 °C Yes - On - Yes - Yes - 2-pipe system - Yes - No ¦ Yes 2010 F H1 Excess heat draw Off ¦ On 2012 F H1 with buffer storage tank No ¦ Yes 2014 F H1 prim contr/system pump No ¦ Yes 2015 F H1 Refrig demand 2-pipe system ¦ 4-pipe system 2033 O H2 DHW charging priority No ¦ Yes 11/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 F H2 Excess heat draw Unit Max Min Default value Function user level Operating line 2035 On - Yes - Yes - 2-pipe system - Off ¦ On 2037 F H2 with buffer storage tank No ¦ Yes 2039 F H2 prim contr/system pump No ¦ Yes 2040 F H2 Refrig demand 2-pipe system ¦ 4-pipe system Primary controller / system pump 2110 O Flow temp setpoint min 2111 O Flow temp setpoint max 2112 O Flow setpoint, cooling min 2130 O Mixing valve boost 2131 O Mixing valve cooling offset 2132 O Actuator type 8 8 80 8 8 8 10 0 0 0 3-position 95 95 20 50 20 °C °C °C °C °C - 2 0 120 30 32 1 120 10 After buffer st tank 20 873 100 873 °C s °C s - 8 4 −−− −−− 20 07:00 19:00 −−− −−− −−− −−− None 0 0 −−−/8 −−−/5 5 00:00 00:00 −−−/1 − − − / -20 − − − / 30 − − − / 60 40 40 95 60 120 23:50 23:50 20 5 350 350 °C °C °C min s hh:mm hh:mm Min/°C °C °C °C - 30 200 1 10 100 1500 % l/h 2-position ¦ 3-position 2133 2134 2135 2136 2150 O O O O I Switching differential 2-pos Actuator running time Mixing valve Xp Mixing valve Tn Primary controller / system pump Before buffer st tank ¦ After buffer st tank Solar 38104) 38114) 38124) 38304) 38314) 38324) 38334) 38344) 38404) 38504) 38604) 38804) F F F O F O O F F F F F Temp diff on Temp diff off Charg temp min DHW st tank Collector start function Min run time collector pump Collector start function on Collector start function off Collector start funct gradient Collector frost protection Collector overtemp prot Evaporation heat carrier Antifreeze None ¦ Ethylene glycol ¦ ¦ Propylene glycol ¦ Ethyl and propyl glycol 38814) F Antifreeze concentration 38844) F Pump capacity DHW storage tank 50104) O Charging Several times / day - Once/day ¦ Several times/day 50204) F 50214) F 50224) F Flow setpoint boost Increase of transfer boost Type of charging 16 0 8 0 With B3 and B31 30 30 °C °C - 5 0 150 − − − / 10 Automatically 20 600 °C min - 80 BZ 5051 OEM °C with B3 ¦ With B3 and B31 ¦ Legio B3 and B31 50244) O 50304) O 50404) O Switching differential Charging time limitation Discharging protection Off ¦ Always ¦ Automatically 5050 4) F Charging temperature max 8 12/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 8 8 Unit 90 80 Off Max Storage tank temp max Recooling temp Recooling heat gen/HCs Min Default value Function user level Operating line 50514) O 50554) F 50564) F 95 95 °C °C - Off ¦ On 5057 4) F Recooling collector Off - Substitute - DHW release - DHW sensor - On - Off ¦ Summer ¦ Always 50604) F electric immersion heater:operating mode Substitute ¦ Summer ¦ Always 50614) F Electric immersion heater release 24h/day ¦ DHW release¦ Time program4/ DHW 50624) F El immersion heater control External thermostat ¦ DHW sensor 50704) O Automatic push Off ¦ On 50714) O 50854) F Charging prio time push Excess heat draw 0 On 0 120 min - Off ¦ On 5090 4) F With buffer storage tank No - No - Yes - No ¦ Yes 50924) F With primary controller / system pump No ¦ Yes 50934) F With solar integration No ¦ Yes 51204) 51244) 51254) 51264) 51304) O O O O O Mixing valve boost Actuator running time Mixing valve Xp Mixing valve Tn Transfer strategy 2 120 32 120 Always 0 30 1 10 50 873 100 873 °C s °C s 480 200 873 30 s °C s s Always ¦ DHW release 51314) O Comparison temp transfer DHW sensor B3 DHW sensor B3 ¦ DHW sensor B31 Instantaneous DHW heater 55444) F Actuator running time 55454) O Mixing valve Xp 55464) O Mixing valve Tn 55474) O Mixing valve Tv Configuration 5710 I Heating circuit 1 60 20 150 4.5 7.5 1 10 0 On - Off ¦ On 5711 I Cooling circuit 1 - Off ¦ 4-pipe system ¦ 2-pipe system 5712 I Use of mixing valve 1 Heating and cooling - Off - Sensors - Charging pump - None - Heating ¦ Cooling ¦ Heating and cooling 5715 I Heating circuit 2 Off ¦ On 57304) I DHW sensor B3 Sensor ¦ Thermostat 57314) I DHW control element Q3 None ¦ Charging pump ¦ Diverting valve 58904) I Relay output QX1 None ¦ Circulating pump Q4 ¦ El imm heater DHW K6 ¦ Collector pump Q5 ¦ H1 pump Q15 ¦ Alarm output K10 ¦ 2nd pump speed HC1 Q21 ¦ 2nd pump speed HC2 Q22 ¦ 2nd pump speed HCP Q23 ¦ Heat circuit pump HCP 13/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 Unit Max Min Default value Function user level Operating line Q20 ¦ H2 pump Q18 ¦ System pump Q14 ¦ Scheduler 5 K13 ¦ DHW mixing pump Q35 ¦ DHW iterm circ pump Q33 ¦ Heat request K27 ¦ Refrig request K28 ¦ Air dehumidifier K29 ¦ Diverting valve, cooling Y21 59304) I Sensor input BX1 None - None - Optg mode changeover HCs+DHW - N/O - None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW circulation sensor B39 ¦ DHW charging sensor B36 ¦ Solar flow sensor B63 ¦ Solar return sensor B64 59314) I Sensor input BX2 None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW circulation sensor B39 ¦ DHW charging sensor B36 ¦ Solar flow sensor B63 ¦ Solar return sensor B64 5950 I Function input H1 Optg mode changeover HCs + DHW ¦ Optg mode changeover HCs ¦ Optg mode changeover HC1 ¦ Optg mode changeover HC2 ¦ Optg mode changeover HCP ¦ Error/alarm message ¦ Min flow temp setpoint ¦ Excess heat discharge ¦ Dewpoint monitor ¦ Flow temp. setpt increase, hygro ¦ Refrig request ¦ Heat request 10V ¦ Refrig. request 10V ¦ Pressure measurement 10V ¦ Rel. room humidity 10V ¦ Room temperature 10V 5951 I Contact type H1 NC ¦ NO 5952 5953 5954 5955 5956 6014 I I I I I I Function value, contact type H1 Voltage value 1, H1 Function value 1, H1 Voltage value 2, H1 Function value 2, H1 Function mixing group 1 70 8 0 0 0 -100 10 0 70 -100 Heating circuit 130 10 500 10 500 °C Volt Volt - Heating circuit 1 ¦ Prim contr/system pump ¦ DHW primary controller4) ¦ Instantaneous DHW heater4) ¦ Cooling circuit 1 ¦ Heating circuit / Cooling circuit 1 6020 I Function extension module 1 None - None - None - None - No function ¦ Multifunctional ¦ Heating circuit 2 ¦ Solar DHW4) ¦ Prim contr/system pump ¦ DHW primary controller4) ¦ Instantaneous DHW heater4) ¦ Cooling circuit 1 6021 I Function extension module 2 No function ¦ Multifunctional ¦ Heating circuit 2 ¦ Solar DHW4) ¦ Prim contr/system pump ¦ DHW primary controller4) ¦ Instantaneous DHW heater4) ¦ Cooling circuit 1 6030 I Relay output QX21 None ¦ Circulating pump Q44) ¦ None ¦ Circulating pump Q44) ¦ El imm heater DHW K6 ¦ Collector pump Q54) ¦ H1 pump Q15 ¦ Alarm output K10 ¦ 2nd pump speed HC1 Q21 ¦ 2nd pump speed HC2 Q22 ¦ 2nd pump speed HCP Q23 ¦ Heat circuit pump HCP Q20 ¦ H2 pump Q18 ¦ System pump Q14 ¦ Scheduler 5 K13 ¦ DHW mixing pump Q354) ¦ DHW iterm circ pump Q334) ¦ Heat request K27 ¦ Refrig request K28 ¦ Air dehumidifier K29 ¦ Diverting valve, cooling Y21 6031 I Relay output QX22 None ¦ Circulating pump Q44) ¦ El imm heater DHW K6 ¦ Collector pump Q54) ¦ H1 pump Q15 ¦ Alarm output K10 ¦ 2nd pump speed HC1 Q21 ¦ 2nd pump speed HC2 Q22 ¦ 2nd pump speed HCP Q23 ¦ Heat circuit pump HCP Q20 ¦ H2 pump Q18 ¦ System pump Q14 ¦ Scheduler 5 K13 ¦ DHW mixing pump Q354) ¦ DHW iterm circ pump Q334) ¦ Heat request K27 ¦ Refrig request K28 ¦ Air dehumidifier K29 ¦ Diverting valve, 14/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 Unit Max Min Default value Function user level Operating line cooling Y21 6032 I Relay output QX23 None - None - None - Optg mode changeover HCs+DHW - N/O - None ¦ Circulating pump Q44) ¦ None ¦ Circulating pump Q44) ¦ El imm heater DHW K6 ¦ Collector pump Q54) ¦ H1 pump Q15 ¦ Alarm output K10 ¦ 2nd pump speed HC1 Q21 ¦ 2nd pump speed HC2 Q22 ¦ 2nd pump speed HCP Q23 ¦ Heat circuit pump HCP Q20 ¦ H2 pump Q18 ¦ System pump Q14 ¦ Scheduler 5 K13 ¦ DHW mixing pump Q354) ¦ DHW iterm circ pump Q334) ¦ Heat request K27 ¦ Refrig request K28 ¦ Air dehumidifier K29 ¦ Diverting valve, cooling Y21 60404) I Sensor input BX21 None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW circulation sensor B39 ¦ DHW charging sensor B36 ¦ Solar flow sensor B63 ¦ Solar return sensor B64 60414) I Sensor input BX22 None ¦ DHW sensor B31 ¦ Collector sensor B6 ¦ DHW circulation sensor B39 ¦ DHW charging sensor B36 ¦ Solar flow sensor B63 ¦ Solar return sensor B64 6046 I Function input H2 Optg mode changeover HCs + DHW ¦ Optg mode changeover HCs ¦ Optg mode changeover HC1 ¦ Optg mode changeover HC2 ¦ Optg mode changeover HCP ¦ Error/alarm message ¦ Min flow temp setpoint ¦ Excess heat discharge ¦ Dewpoint monitor ¦ Flow temp. setpt increase, hygro ¦ Refrig request ¦ Heat request 10V ¦ Refrig. request 10V ¦ Pressure measurement 10V ¦ Rel. room humidity 10V ¦ Room temperature 10V 6047 I Contact type H2 NC ¦ NO 6048 6049 6050 6051 6052 60974) I I I I I F Function value, contact H2 Voltage value 1, H2 Function value 1, H2 Voltage value 2, H2 Function value 2, H2 Sensor type collector 70 8 0 0 0 -100 10 0 70 -100 NTC 10k 130 10 500 10 500 °C Volt Volt - 0 0 15 60 Off -20 -3.0 0 0 20 3.0 50 300 °C °C h Min/°C - −−− −−− Off − − − / -50 − − − / -50 50 50 °C °C - NTC 10k ¦ Platinum 1000 6098 6100 6110 6112 6120 4) F F F O F Readjustm collector sensor Readjustm outside sensor Time constant building Gradient room model Frost protection for the plant Off ¦ On 6128 F 6129 F 61314) F Heat request below OT Heat request above OT Heat req in economy mode Off ¦ On DHW ¦ On 6135 F Air dehumidifier Off - 24 h/day - Off ¦ On 6136 F Air dehumidifier enable 24h/day ¦ Time progr. heating circuit ¦ Time program 5 6137 6138 6140 6141 6142 F F O O O Air dehumidifier r.h. EIN Air dehumidifier r.h. SD Water pressure max Water pressure min Water pressure critical min 55 5 −−− −−− −−− 0 2 − − − / 0.0 − − − / 0.0 − − − / 0.0 100 50 10.0 10.0 10.0 % % bar bar bar 15/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 6204 O Save parameters −−− −−− −−− No − − − / 0.0 − − − / 0.0 − − − / 0.0 Unit Water pressure 2 max Water pressure 2 min Water press 2 critical min Save sensors Max O O O I Min Default value Function user level Operating line 6150 6151 6152 6200 10.0 10.0 10.0 bar bar bar - No ¦ Yes No - No - No ¦ Yes 6205 F Reset to default parameters No ¦ Yes 62124) I Check-No. heat source 1 6215 I Check-No. storage tank 6217 I Check-No. heating circuits 6220 F Software version 6222 O Device hours run LPB-System 6600 I Device address 6601 F Segment address 6604 F Bus power supply function 0 0 0 0 0 0 1 0 0 0 Automatically 199999 199999 199999 99.9 65535 h 16 14 - Off ¦ Automatically 6605 F Bus power supply state On - Yes - Off ¦ On 6610 O Display system messages No ¦ Yes 6612 6620 O O Alarm delay Action changeover functions 6621 F Summer changeover −−− −−−/2 System 60 min - Segment ¦ System Locally - Centrally - All HCs in system - Locally - Autonomously - Locally¦ Centrally 6623 F Optg mode changeover Locally¦ Centrally 6625 F Assignment of DHW heating Local HCs ¦ All HCs in segment ¦ All HCs in system 6627 F Refrigeration demand Locally¦ Centrally 6640 I Clock mode Autonomously ¦ Slave without remote ¦ Slave with remote setting ¦ Master 6650 F Faults 6710 I Outside temp source 0 Reset alarm relay No 0 239 - No ¦ Yes 6740 6741 67454) 6746 6800 6802 6804 6806 F F F F F F F F F F F Flow temp 1 alarm Flow temp 2 alarm DHW charging alarm Flow temp alarm, cooling 1 History 1 Error code 1 History 2 Error code 2 History 3 Error code 3 History 4 −−− −−− −−− −−− - − − − / 10 − − − / 10 −−−/1 − − − / 10 240 240 48 240 min min h min 0 255 - 0 255 - 0 255 - 16/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 6810 6812 6814 6816 6818 6820 F F F F F F F F F F F F F O Error code 4 History 5 Error code 5 History 6 Error code 6 History 7 Error code 7 History 8 Error code 8 History 9 Error code 9 History 10 Error code 10 Reset history No Unit Max Min Default value Function user level Operating line 6808 0 255 - 0 255 - 0 255 - 0 255 - 0 255 - 0 255 - 0 255 - 240 240 Months Months - No ¦ Yes Maintenance / special operation 7044 F Maintenance interval 7045 F Time since maintenance 71194) F Economy function −−− −−−/1 0 0 Locked Locked ¦ released 71204) E Economy mode Off - Off - Off ¦ On 7140 E manual operation Off ¦ On 7150 I Simulation outside temperature 7170 I Telephone customer service Input / output test 7700 I Relay test - -50.0 50 No test °C - No test ¦ Everything off ¦ DHW pump Q3 ¦ Heating circuit pump Q2 ¦ Heating circ mix valve op Y1 ¦ Heat circ mix valve cl Y2 ¦ Relay output QX14) ¦ Relay output QX21 module 1 ¦ Relay output QX22 module 1 ¦ Relay output QX23 module 1 ¦ Relay output QX21 module 2 ¦ Relay output QX22 module 2 ¦ Relay output QX23 module 2 7730 7732 77504) 78204) 78214) 78304) 78314) 78324) 78334) 7840 7841 I I I I I I I I I I I Outside temp B9 Flow temp B1 DHW temp B3 Sensor temp BX1 Sensor temp BX2 Sensor temp BX21 module 1 Sensor temp BX22 module 1 Sensor temp BX21 module 2 Sensor temp BX22 module 2 Voltage signal H1 Contact state H1 7845 7846 I I Voltage signal H2 Contact state H2 0 0 0 0 - -50.0 0.0 0.0 -28.0 -28.0 -28 -28 -28 -28 0 50 140 140 350 350 350 350 350 350 10 °C °C °C °C °C °C °C °C °C Volt - 0 - 0 10 Volt - Open ¦ Closed Open ¦ Closed State 8000 I State of heating circuit 1 - 17/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 - Unit Max Min Default value Function user level Operating line 8001 I State of heating circuit 2 8002 I State heating circuit P 8003 I State of DHW 8004 I State of cooling circuit 1 80074) I State of solar Diagnostics, heat generation 85104) I Collector temp 1 85114) I Collector temp 1 max 85124) I Collector temp 1 min 85134) I dT collector 1/DHW 85194) I Solar flow temp 4) 8520 I Solar return temp 85264) E 24-hour yield solar energy 85274) E Total yield solar energy 85304) F Hours run solar yield 85314) F Hours run collect overtemp Diagnostics, consumers 8700 I Outside temperature (OT) 8703 I Outside temp attenuated 8704 I Outside temperature composite 8720 I Relative room humidity 8721 I Outside temperature (OT) 8722 I Dewpoint temperature 1 8730 I Heating circuit pump Q2 - 0 0 0 0 0 0 - -28.0 -28.0 -28.0 -168.0 -28.0 -28.0 0 0 0 0 350 350 350 350 350 350 999.9 9999999.9 65535 65535 °C °C °C °C °C °C kWh kWh h h - -50.0 -50.0 -50.0 0 0 0 50.0 50.0 50.0 100 50.0 50.0 °C °C °C % °C °C - Off ¦ On 8731 I Heating circ mix valve op Y1 - - - - Off ¦ On 8732 I Heat circ mix valve cl Y2 Off ¦ On 8740 8741 8742 8743 8744 8751 I I O I I I Room temp 1 Room setpoint 1 Room temp 1 model Flow temperature 1 Flow temp setpoint 1 Cooling circuit pump 1 8752 I Cooling circuit mixing valve 1 Open - 0.0 4.0 0.0 0.0 0.0 50.0 35.0 50.0 140.0 140.0 °C °C °C °C °C - Off ¦ On - - - - - - Off ¦ On 8753 I Cooling circuit mixing valve 1 Closed Off ¦ On 8754 I Cooling diverting valve 1 Off ¦ On 8756 8757 8760 I I I 8761 I Flow temperature, cooling 1 Flow temperature, cooling 1 Heating circuit pump 2 - 0 0 140 140 °C °C - Off ¦ On Heat circ mix valve 2 open - - - - Off ¦ On 8762 I Heat circ mix valve 2 close Off ¦ On 18/32 Siemens Switzerland Ltd HVAC Products User Manual Overview of OEM settings CE1U2353en01a 7 November 2007 Default value 8830 8831 88324) 88354) 88364) 88504) 88514) 88524) 88534) 8930 8931 89504) 89514) 89574) 9000 9001 9005 9006 90314) I I I I I I I I I I I I I I I I I I I DHW temp 1 DHW temp setpoint DHW temp 2 DHW circulation temp DHW charging temp DHW primary controller temp DHW primary controller setp Instant DHW heater temp Instant DHW heater setpoint Primary controller temp Primary controller setpoint Common flow temp Common flow temp setpoint Common flow temp setpoint refrig Flow temperature setpoint H1 Flow temp setpoint H2 Water pressure H1 Water pressure H2 Relay output QX1 9050 I Unit Room temp 2 Room setpoint 2 Room temp 2 model Flow temperature 2 Flow temp setpoint 2 Room temp P Room setpoint P Room temp P model Flow temp setpoint P DHW pump Q3 Max I I O I I I I O I I Min Function user level Operating line 8770 8771 8772 8773 8774 8800 8801 8802 8803 88204) - 0.0 4.0 0.0 0.0 0.0 0.0 4.0 0.0 0.0 50 35 50 140 140 50 35 50 140 °C °C °C °C °C °C °C °C °C - 0 0 0 0 0 0 - 0.0 8.0 0.0 0.0 0 0 0 0 0 0.0 0.0 0.0 0.0 0 5.0 5.0 0.0 0.0 140 80 140 140 140 140 140 140 140 140.0 140.0 140.0 140.0 140 130.0 130.0 10.0 10.0 °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C bar bar - Off ¦ On Off ¦ On Relay output QX21 module 1 - - - - - - - - - - - - Off ¦ On 9051 I Relay output QX22 module 1 Off ¦ On 9052 I Relay output QX23 module 1 Off ¦ On 9053 I Relay output QX21 module 2 Off ¦ On 9054 I Relay output QX22 module 2 Off ¦ On 9055 I Relay output QX23 module 2 Off ¦ On 19/32 Siemens Switzerland Ltd HVAC Products User Manual OEM Overview of OEM settings CE1U2353en01a 7 November 2007 2 The settings in detail 2.1 Operator section Operation and display Line no. Operating line 21 Display special operation Off On 30 Save basic settings No Yes 31 Activate basic settings No Yes Save basic settings The setting data of all operating levels are copied from the controller to the memory of the operator unit. This means that previous data in the operator unit are overwritten. Activate basic settings With the exception of the data listed below, the setting data of all operating levels are transferred from the memory of the operator unit to the connected controller. Previous setting data in the controller are overwritten. The following operating lines will not be overwritten: Line no. 6600 6601 6222 Operating line Device address Segment address Device hours run The following data will not be overwritten either: RF list, hours run / start counter, yield meter, maintenance meter, slave pointer, and error history. 2.2 Heating circuits Mixing valve control HC1 835 836 Mixing valve Xp Line no. HC2 HC3P 1135 1136 Operating line Mixing valve Xp Mixing valve Tn By setting the right proportional band, the control action of the mixing valve actuator is matched to the behavior of the plant (controlled system). Xp influences the controller’s P-action. Mixing valve Tn By setting the right integral action time, the control action of the mixing valve's actuator is matched to the behavior of the plant (controlled system). Tn influences the controller’s I-action. 20/32 Siemens Switzerland Ltd HVAC Products User Manual The settings in detail CE1U2353en01a 7 November 2007 2.3 Cooling circuit Mixing valve control Mixing valve Xp Line no. Operating line 942 943 Mixing valve Xp Mixing valve Tn By setting the right proportional band, the control action of the mixing valve actuator is matched to the behavior of the plant (controlled system). Xp influences the controller’s P-action. Mixing valve Tn By setting the right integral action time, the control action of the mixing valve's actuator is matched to the behavior of the plant (controlled system). Tn influences the controller’s I-action. 2.4 DHW Setpoints Line no. Operating line 1614 nominal setpoint max This operating line is used to limit the “Nominal setpoint“ (operating line 1610) at the top. 2.5 Hx pumps Pump Hx H1 Line no. H2 2008 2033 Operating line H1/H2 DHW charging priority Off ¦ On H1/H2 DHW charging priority When using this setting, the connected pump H can be excluded from / included in the effect of DHW charging priority. In the case of a ventilation system, for example, it is thus possible to ensure a constant supply of heat with no impact from the DHW charging priority. 2.6 Primary controller / system pump Flow temperature setpoint limits Line no. Operating line 2110 2111 2112 Flow temp setpoint min Flow temp setpoint max Flow setpoint, cooling min 21/32 Siemens Switzerland Ltd HVAC Products User Manual OEM The settings in detail CE1U2353en01a 7 November 2007 These limit values can be used to define a temperature range for the heating flow temperature setpoint. TV TVmax max 2358Z09 Flow temp setpoint minimum/maximum TVw akt TVmin min 0 TVw TVmax Tvmin Flow setpoint, cooling min 10 20 30 40 50 60 70 80 90 100 °C Current flow temperature setpoint Flow temp setpoint max Flow temp setpoint minimum This limit value can be used to define the low limit for the flow temperature setpoint for cooling. Mixing valve control Line no. Operating line 2130 2131 2132 2133 2134 2135 2136 Mixing valve boost Mixing valve cooling offset Actuator type Switching differential 2-pos Actuator running time Mixing valve Xp Mixing valve Tn Mixing valve boostFor mixing, the actual value of the boiler flow temperature must be higher than the required setpoint of the mixing valve flow temperature since otherwise that temperature cannot be controlled. The controller generates the boiler temperature setpoint based on the increase set here and the current flow temperature setpoint. Mixing valve cooling offset RVS46.543 only To ensure proper mixing, the actual flow temperature of the cooling aggregate must be lower than the required mixing valve flow temperature setpoint. The cooling demand is reduced by the value set here. 2.7 Solar Start function Collector start function Line no. Operating line 3830 3832 3833 Collector start function Collector start function on Collector start function off If the temperature at the collector (especially in the case of vacuum tubes) cannot be correctly acquired when the pump is deactivated, the pump can be activated from time to time. 22/32 Siemens Switzerland Ltd HVAC Products User Manual The settings in detail CE1U2353en01a 7 November 2007 RVS46.543 only 2.8 DHW storage tank Release Line no. Operating line 5010 Charging Once/day ¦ Several times/day Charging Selection of charging “Once/day“ or “Several times/day” is active only if DHW release is set according to the time programs of the heating circuits Once / day Release of DHW charging is given 2.5 hours before the first heat request from the heating circuit is received. Then, the reduced DHW setpoint applies for the whole day. Heizprogramm Time program Einmal Once perpro day Tag DHW release TWW-Freigabe 2.5h In the case of continuous heating (with no setback periods), release of DHW charging is given at 0:00. The same rule also applies if the first request for heat from the heating circuit is received before 02:30. If a request for heat is received at midnight, DHW charging is released after the first setback period, but no earlier than 2.5 hours before midnight. Day Tag11 Day Tag2 2 Day 33 Tag Day Tag4 4 Time program Heizprogramm DHW release TWW-Freigabe 2.5h 0:00 24:00 2.5h 2.5h 22:00 2.5h Several times / day When selecting “Several times/day“, release of DHW charging is put forward in time by 1 hour against the periods of time the heating circuit calls for heat, and is then maintained during those periods of time. Heizprogramm Time program Several times perTag Mehrmals pro day DHW release TWW-Freigabe 1h 1h Charging control Switching differential Line no. Operating line 5024 Switching differential If the DHW temperature is lower than the current setpoint minus the switching differential set here, DHW charging will be started. DHW charging will be terminated when the temperature reaches the current setpoint. When DHW heating is released for the first time in a 24-hour period, forced charging will be initiated. DHW charging is also started when the DHW temperature lies within the switching differential, provided it does not lie less than K below the setpoint. 23/32 Siemens Switzerland Ltd HVAC Products User Manual OEM The settings in detail CE1U2353en01a 7 November 2007 Charging time limitation Charging time limitation Line no. Operating line 5030 Charging time limitation During DHW charging, space heating may obtain no or too little energy, depending on the selected charging priority (operating line 1630) and the type of hydraulic circuit. For this reason, it is often practical to set a time limit to DHW charging. --Charging time limitation is deactivated. The DHW is heated up to the nominal setpoint, even if space heating cannot draw sufficient amounts of heat for a certain period of time. 10 – 600 DHW charging is stopped after the set period of time in minutes and then locked for the same period of time before it is resumed. During this period of time, the heat produced by the boiler is made available for space heating. This cycle is repeated until the nominal DHW setpoint is reached. When space heating is switched off (summer operation, Eco function, etc.), DHW charging will not be stopped, independent of the selected setting. Discharging protection Discharging protection Line no. Operating line 5040 Discharging protection This function ensures that the DHW charging pump (Q3) will be activated only when the boiler temperature is high enough. • With sensor The charging pump will be activated only when the boiler temperature reaches the level of the DHW temperature plus one half the charging boost. If, during charging, the boiler temperature drops to a level below the DHW temperature plus 1/8 the charging boost, the charging pump will be deactivated again. If 2 DHW sensors are parameterized for DHW charging, the lower temperature is used for the discharging protection function (usually sensor B31). • With thermostat The charging pump will be activated only when the boiler temperature lies above the nominal DHW setpoint. If, during charging, the boiler temperature drops below the nominal DHW temperature minus the DHW switching differential, the charging pump will be deactivated again. Off Function is deactivated. Always The function is always active. Automatically The function is active only if the heat source is not able to deliver heat, or is not available (fault, heat generation lock). Overtemperature protection 24/32 Siemens Switzerland Ltd HVAC Products User Manual The settings in detail CE1U2353en01a 7 November 2007 Storage tank temp max Line no. Operating line 5051 Storage tank temp max If the storage tank reaches the maximum storage tank temperature set here, charging is aborted. It will be released again when the storage tank temperature has dropped 1 °C below the maximum storage tank temperature. The protective collector overtemperature function can reactivate the collector pump until the storage tank’s safety temperature is reached. T TSpMax TSp L 2354Z10 1°C 1 0 t TSpMax TSp L Storage tank temp max (operating line 5051) Actual value of the storage tank temperature Storage tank charging: 1 = on, 0 = off DHW push Line no. Operating line 5070 Automatic push Off On 5071 Automatic push Charging prio time push The DHW push can be triggered either manually or automatically. In that case, the DHW is heated up once to the nominal setpoint. Off The DHW push must be triggered manually. On If the DHW temperature falls below the reduced setpoint (operating line 1612) by at least 2 switching differentials (operating line 5024), one-time charging to the nominal DHW setpoint (operating line 1610) will take place again. The automatic DHW push only works when the DHW operating mode is activated. Charging prio time push In the case of a DHW push, the DHW storage tank is charged with absolute priority for the period of time set here. Mixing valve precontrol Line no. Operating line 5120 5124 5125 5126 Mixing valve boost Actuator running time Mixing valve Xp Mixing valve Tn 25/32 Siemens Switzerland Ltd HVAC Products User Manual OEM The settings in detail CE1U2353en01a 7 November 2007 Mixing valve boost To ensure proper mixing valve flow temperature control, the flow temperature must be higher than the demanded setpoint of the mixing valve flow temperature. The value set here is added to the request. Actuator running time Setting the running time of the actuator used with the mixing valve. Mixing valve Xp By setting the right proportional band, the control action of the mixing valve’s actuator is matched to the behavior of the plant (controlled system). Xp influences the controller’s P-action. Mixing valve Tn By setting the right integral action time, the control action of the mixing valve's actuator is matched to the behavior of the plant (controlled system). Tn influences the controller’s I-action. Transfer Line no. Operating line 5130 Transfer strategy 5131 Comparison temp transfer Always ¦ DHW release DHW sensor B3 ¦ DHW sensor B31 Transfer strategy Transfer is permitted either always or at the release times set (operating line 1620). Comparison temp transfer For the transfer, the respective DHW sensor can be selected to get a comparative temperature. RVS46.543 only 2.9 Instantaneous DHW heater Mixing valve control Mixing valve Xp Line no. Operating line 5545 5546 5547 Mixing valve Xp Mixing valve Tn Mixing valve Tv By setting the right proportional band, the control action of the mixing valve’s actuator is matched to the behavior of the plant (controlled system). Xp influences the controller’s P-action. Mixing valve Tn By setting the right integral action time, the control action of the mixing valve's actuator is matched to the behavior of the plant (controlled system). Tn influences the controller’s I-action. Mixing valve Tv By setting the right derivative action time, the control action is matched to the behavior of the plant (controlled system). Tv influences the controller’s D-action. With Tv = 0, the D-action is deactivated. 26/32 Siemens Switzerland Ltd HVAC Products User Manual The settings in detail CE1U2353en01a 7 November 2007 2.10 Configuration Building and room model Gradient room model Line no. Operating line 6112 Gradient room model The room model gradient gives the period of time in minutes room heating needs to raise the temperature by 1 °C. The settings made applies to all circuits. The setting is used to calculate the fictive room temperature of rooms that have no room temperature sensor installed (operating lines 8742, 8772, and 8802). Pressure acquisition H1, H2 H1 Line no. H2 6140 6150 6141 6151 6142 6152 Water pressure max Operating line Water pressure max Water pressure min Water pressure critical min If the pressure acquired at input H1 or H2 exceeds the limit value set here, an error message will be delivered. 117: Water pressure too high 176: Water pressure 2 too high If the pressure drops below the limit value by one switching differential, the error will be cancelled. Water pressure min If the pressure acquired at input Hx drops below the set limit value (parameter “Water pressure min“), the appropriate maintenance alarm will be delivered. 5: Water pressure too low 18: Water pressure 2 too low If the pressure exceeds the limit value by one switching differential, the error is cancelled. Water pressure critical min If the pressure acquired at input H1 or H2 falls below the limit value set here, an appropriate error message will be delivered and both burner stages immediately shut down. 118: Water pressure too low 177: Water pressure 2 too low If the pressure exceeds the limit value by one switching differential, the error is cancelled. Device hours run Line no. Operating line 6222 Device hours run This indicates the total number of hours run since the controller was first commissioned. 27/32 Siemens Switzerland Ltd HVAC Products User Manual OEM The settings in detail CE1U2353en01a 7 November 2007 2.11 LPB system Error/maintenance/alarms Line no. Operating line 6610 6612 Display system messages Alarm delay Display system messages This setting enables system messages transmitted via LPB to be suppressed at the connected operator unit. Alarm delay Delivery of the alarm to the OCI can be delayed in the basic unit by setting a delay. This ensures that unnecessary notifications of a service center resulting from short-time errors (e.g. temperature limiter cut out, communication error) can be prevented. It is to be noted, however, that errors occurring for a short period of time, and reoccurring constantly and rapidly, will also be filtered. Action changeover functions Line no. Operating line 6620 Action changeover functions Segment ¦ System The setting is only relevant for device address 1. Range of action of changeover The range of action of central changeover can be defined. This concerns: Summer changeover (when selecting ”Central“ on line 6623) Summer changeover (with ”Central“ setting on operating line 6621) Entries: Segment: Changeover takes place with all controllers in the same segment. System: Changeover takes place with all controllers in the entire system (in all segments). The controller must be located in segment 0! 2.12 Faults History 1..10 Line no. Operating line 6820 Reset history No Yes Reset history The error history with the last 10 errors will be deleted. 28/32 Siemens Switzerland Ltd HVAC Products User Manual The settings in detail CE1U2353en01a 7 November 2007 2.13 Diagnostics, consumers Heating circuit 1, heating circuit 2, heating circuit P Room temperature 1 / 2 / P model Line no. Operating line 8742 8772 8802 Room temp 1 model Room temp 2 model Room temp P model The room model calculates a fictive room temperature for rooms that have no room temperature sensor. The value calculated for each heating circuit is indicated on these operating lines. This allows boost heating, quick setback and optimum start and stop control to be implemented with no need for using a room temperature sensor. The calculation takes into account the attenuated outside temperature (operating line 8703), the room model gradient (operating line 6112) for switching to a higher setpoint and the building’s time constant (operating line 6110) for switching to a lower setpoint. 29/32 Siemens Switzerland Ltd HVAC Products User Manual OEM The settings in detail CE1U2353en01a 7 November 2007 Index A Action changeover functions .....................................28 Actuator running time ................................................22 Actuator runtime DHW ..............................................25 Actuator type primary controller / system pump ........22 Alarm delay ...............................................................28 Attenuated outside temperature ................................29 Automatic push..........................................................25 B Building’s time constant.............................................29 C Charging DHW ..........................................................23 Charging prio time push ............................................25 Charging time limitation.............................................24 Collector start function solar......................................22 Comparison temp transfer.........................................26 Copy settings.............................................................20 D Data Read ....................................................................20 Write.....................................................................20 Device hours run .......................................................27 DHH charging Hx pump ............................................21 DHW..........................................................................21 DHW charging ...........................................................23 DHW nominal setpoint, maximum .............................21 DHW push .................................................................25 DHW switching differential ........................................23 Discharging protection...............................................24 Display system messages.........................................28 E Error history...............................................................28 Error/maintenance/alarms .........................................28 F Flow setpoint limitations ............................................21 Flow setpoint, cooling min .........................................22 Flow temp setpoint max ............................................22 Flow temp setpoint min .............................................22 G Gradient room model...........................................27, 29 H Heating circuits..........................................................20 History reset ..............................................................28 Hours run device .......................................................27 Hx pumps ..................................................................21 I Instantaneous DHW heater .......................................26 L Limitation of charging time ........................................24 LPB system .............................................................. 28 M Mixing valve Integral action time.............................................. 22 P-band................................................................. 22 Mixing valve boost .................................................... 22 Mixing valve boost DHW .......................................... 25 Mixing valve cooling offset........................................ 22 Mixing valve derivative action time Tn DHW ............ 26 Mixing valve heating circuit....................................... 20 Mixing valve integral action time Tn DHW.......... 25, 26 Mixing valve integral action time Tn heating circuit .. 20 Mixing valve P-band Xp DHW ............................ 25, 26 Mixing valve P-band Xp, heating circuit.................... 20 Mixing valve precontrol DHW ................................... 25 Model room temperature 1 / 2 / P............................. 29 O Once / day ................................................................ 23 Optimum start control ............................................... 29 Optimum stop control ............................................... 29 P P-band Xp heating circuit ......................................... 20 Pressure measurement ............................................ 27 Primary controller / system pump ............................. 21 Protection against overtemperatures........................ 25 push.......................................................................... 25 Q Quick setback / boost heating .................................. 29 R Reset Error history......................................................... 28 Room model gradient ............................................... 27 Room temperature model 1 / 2 / P ........................... 29 S Setpoint DHW........................................................... 21 Several times / day ................................................... 23 Solar ......................................................................... 22 Solar start function.................................................... 22 Storage tank temp max ............................................ 25 Summer changeover ................................................ 28 Switching differential 2-pos....................................... 22 Switching differential DHW ....................................... 23 System messages .................................................... 28 T Transfer strategy DHW ............................................. 26 W Water pressure ......................................................... 27 30/32 Siemens Switzerland Ltd HVAC Products User Manual CE1U2354en01a 7 November 2007 3 Revision history All changes made to the document since the last issue (see front page) are identified with the Winword function "Highlight". To show such text, use the following key combinations: Display: Ctrl Shift (Num) + Hide: Ctrl Shift (Num) Or select the same functionality with the following Winword menu: Menu: [Tools] - [Options] Command: [Highlight] The revision history is not visible in the print file (PDF). 31/32 Siemens Switzerland Ltd HVAC Products User Manual OEM CE1U2353en01a 7 November 2007 Siemens Switzerland Ltd Building Technologies Group / HVAC Products Gubelstrasse 22 CH -6301 Zug Tel. +41 41-724 24 24 Fax +41 41-724 35 22 www.sbt.siemens.com © 2005-2007 Siemens Building Technologies Ltd. Subject to change 32/32 Siemens Switzerland Ltd HVAC Products User Manual OEM CE1U2353en01a 7 November 2007
© Copyright 2025