– IP65 Multi-Data Capture Tablet Quick Manual MetaDolce MD3600 1

MetaDolce MD3600 – IP65 Multi-Data Capture Tablet Quick Manual
1. Keys and Connectors
MetaDolce MD3600 – IP65 Multi-Data Capture Tablet Quick Manual
© MetaDolce Technologies Inc. 2014
1
2.
Technical Specifications
MetaDolce MD3600 – IP65 Multi-Data Capture Tablet Quick Manual
© MetaDolce Technologies Inc. 2014
2
3.
Product Use Recommendations
3.1 Attention: Only use the charger supplied by the manufacturer to recharge the device, other
chargers may cause damage.
Input: 100-240V ~ 50/60 Hz
Output: 5V
2000 mA
3.2
3.3
3.4
3.5
3.6
Only use the USB micro port for charging. Do not connect a charger to the USB host (Mini USB).
Do not disconnect the device from a PC when downloading, uploading or formatting.
Do not disassemble or attempt to repair the unit or components.
Do not use alcohol, thinner or benzene-chemicals to clean the surface of the device.
Please back-up your files. The manufacturer is not responsible for the deletion of files after damage or
repair of the device.
4. Dimensions & Weight
4.1 220 x 132 x 26.5(mm) (8.7" x 5.2" x 1.1")
4.2 0.5Kg (1.1lbs) with battery
5.
5.1
5.2
5.3
5.4
3G Frequencies & Rates
6.
Additional Technical Specifications
WCDMA R99: maximum data rate of 384 kbps, 2100Mhz
GSM R99: Supports CS SMS, 900/1800Mhz
GPRS : CS schemes – CS1, CS2, CS3, and CS4
EDGE : Downlink coding schemes – CS 1-4, MCS 1-9
Operating
-20°C (-4°F) to +70°C (158°F)
MIL-STD-810G
Temperature
<0.5°C / min; 24 hr cycle x 3 cycles
Methods 501.5, 502.5
-40°C (-40°F) to 70°C(158°F)
MIL-STD-810G
<0.5°C / min; 24 hr cycle x 7 cycles
Methods 501.5, 502.5
90% @ 40°C (104°F)
MIL-STD-810G
3 x 24 hr cycles
Method 507.5
Dust Protection
IP6x (dust)
IEC 60529 /AC2:2007
Water Protection
IPx5 (water)
IEC 60529 /AC2:2007
Vibration
Fig 514.6E-1 & 514.6E-2.
Storage Temperature
Relative Humidity
MIL-STD-810G-514.6, Procedure I
Cat. 24,
120CM(47”) drop, 2» plywood over concrete, MIL-STD-810G
Drop Test
each edge, face and corner;
Method 516.6
26 drops total (@ ambient temp)
Procedure IV
MetaDolce MD3600 – IP65 Multi-Data Capture Tablet Quick Manual
© MetaDolce Technologies Inc. 2014
3
7. Install and Remove SIM Card
7.1 Be sure to power off the tablet before you install or remove the SIM card.
7.2 Install SIM card: Open the battery compartment on the back of the device and lift the battery out of the
compartment. The SIM card slot is located beneath the battery; insert the SIM card in the indicated direction.
7.3 Remove SIM card: Open the battery compartment on the back of the device and lift the battery out of the
compartment. The SIM card slot is located beneath the battery; remove the SIM card in the indicated
direction.
8. Install and Remove SD Card
8.1 Install SD card: Open the SD card slot protective cover; insert the SD card in the indicated direction.
8.2 Remove SD card: Before removing the SD card, make sure the SD card is disconnected from the device.
8.3 Click
to enter the applications list>
Settings> Storage> Unmount SD card
8.4 Open the SD card slot protective cover; press the SD card slightly with a fingertip, then the SD card will be
ejected from the slot.
9. Power On and Off: After the battery is charged fully and the SIM card is inserted, you can power on the
device and begin use.
9.1 Power On and Unlock: Press and hold the power button until a vibration occurs. When the device turns on it
will be in locked mode. To unlock the device hold and slide the
icon to the
icon.
9.2 Power Off: Press and hold the power button to bring up the "Device Options" dialog box, select "Power Off",
then select “OK”.
9.3 Sleep Mode: You can tap the power button to turn off the screen and send the device into sleep mode. This
can save battery power and extend battery life. You can also set the delay time before the screen is
automatically locked. To wake up the device, press the power button again. When the device turns on it will
be in locked mode.
10. Battery management and charging
10.1 Charge the battery for 8-12 hours to make sure the battery is fully charged when first used.
10.2 Insert the micro USB end of the charging cable into the micro USB slot on the device and plug the other end
into a power socket. The battery charge indicator will show the battery is in the process of charging.
Observe the charge indicator on your device to know when it is completely charged.
10.3 Note: In order to keep the battery working in the best condition, please pay attention to the following advice:
In order to keep the battery in good condition, please make sure to charge the device once every two weeks
when not in use for extended periods of time.
MetaDolce MD3600 – IP65 Multi-Data Capture Tablet Quick Manual
© MetaDolce Technologies Inc. 2014
4
11. Definitions of Icons and their Functions
Icon
Function
Icon
Back to Main Menu
Function
Menu
Current power status
New peripheral device detected
Current time
Search
Go Back
Application Menu
USB connected
WIFI on/off
Status Bar
MetaDolce MD3600 – IP65 Multi-Data Capture Tablet Quick Manual
© MetaDolce Technologies Inc. 2014
5