Projekt konvertering Konvertering till GX Works2 Projekt konvertering GX Developer GX Works2 GX IEC Developer GX Works2 MELSEC MEDOC GX Works2 | 54 Bakåt kompatibilitet Open Other Data GX Developer Open Other Project Open Other Project GX IEC Developer Open Other Data | 55 Projekt skapade med GX IEC Developer ASCII filer (*.asc) skapade med export från GX IEC Developer kan importeras som projekt i GX Works2 genom att använda funktionen ‘Read ASC Format File’ Menyval: Project/Open Other Data/Read ASC Format File Read ASC Format File | 56 Importera MEDOC projekt via GX Developer till GX Works2 Ändra från A till Q Skapar ‘Ladder’ programkod | 57 Importera MEDOC projekt via GX IEC Developer till GX Works2 Ändra från A till Q Skapar ‘Stuctured Ladder’ programkod | 58 Project Types overview (GX Works2 ver 1.73B) Programming Description language Ladder Structured Text With labels The Mitsubishi “Classic” Ladder editor, similar to GX Developer programming tool. Note, in projects with labels, the Inline Structured Text function can be used. A text language with grammatical structure similar to C language. SFC A graphic language which defines the executing order or condition of a program. Structured Ladder/FBD The IEC 61131-3 Ladder and FBD editor, similar to GX IEC Developer programming tool. The FBD-editor included, from GXW2 1.64S. Instruction List Simple project The low level text language, the ILeditor. Combined IEC IL / Melsec IL editor included, from GXW2 1.73B. OK *1 OK Structured Without labels OK *1 _ OK OK *1 OK OK *1 OK _ _ OK *1 _ _ OK *1 *1 : Supported with the FX CPU | 59 project Demo Konvertera projekt till GX Works2 Demo - Projekt från GX Developer 8 (Q06UDEH-CPU) Demo - Programexempel från GX IEC Developer 7.04 (Q02-CPU) | 60 Common Errors Example of errors from GX Developer import 1. Invalid character in data name during import Solution: Rename before import! | 61 Check program and parameter - GX Works2 2. By menu selection Tool / Check Program / Check Parameter you are able to find other errors in the application Solution: Change to the new Program names in the parameters | 62 Example of errors from GX IEC Developer import 1. File for Library […] does not exist Consequence: Libraries are not imported to GX Works2 | 63 Import User Libraries (*.sul) in GX Works2 1. File for Library […] does not exist Consequence: Error during compilation (Rebuild All) | 64 Import User Libraries (*.sul) in GX Works2 1. File for Library […] does not exist Solution: Reconnect all Libraries after import! | 65 Invalid label name - GX Works2 2. Invalid data name/label name: ’n’ is a reserved name. C5054 Consequence: Error during compilation (Rebuild All) Solution: Rename label name in Local or Global label list | 66 Wrong label - GX Works2 3. Wrong device or label. Not declared. F1001 Consequence: Error during compilation (Rebuild All) | 67 Use Find / Replace to solve the label name error 3. Wrong device or label. Not declared. F1001 Solution: Use Find / Replace function and exchange label name | 68 Reserved characters or name - GX Works2 4. Reserved characters/Invalid characters …’end:’… C1006 Solution: Replace characters / label name Label end: | 69 Renamed instructions - GX Works2 5. Compilation error by wrong or not connected instruction Solution: Replace instruction | 70
© Copyright 2024