13.3” LOW VOLTAGE BedMate II DTV Operations Manual

TM
13.3” LOW VOLTAGE
BedMate II DTV
Operations Manual
MODEL# BM13II
5320
REVISION 3.0
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
Setup
TABLE OF CONTENTS
3
SAFETY INSTRUCTIONS
4-6
PACKAGE CONTENTS
6
PRODUCT INTRODUCTION
IR Remote Control
I/O Panels
Keypad
7-8
7
8
8
INSTALLATION
BASIC CONNECTIONS
PC
Pillow Speaker/Sip & Puff
USB Port
RJ-12 Serial Port
HDMI
Cable
Earphone/Headphone
9-11
12
12
12
12
12
12
12
12
SETUP AND OPERATION
Remote Batteries
Function Codes
Auto Scan
Cloning
13
13
13
13
13
ADVANCED SETUP
Video
Picture Settings
Screen Mode
Brightness
Contrast
Saturation
Hue
Sharpness
Screen Mode
Auto
Normal
Letterbox
Zoom
Dot by Dot
VGA Settings
Auto Adjust
Horz/Vert Position
Width
Clock
Color Temperature
Video Noise Reduction
DNR
MPEG Noise Reduction
DI File Mode
Audio
Sound Settings
Balance
Base
Treble
Surround Sound
Equalizer
Other Settings
Auto Volume Control
SPDIF
Keypad Buzzer
Wireless Audio
TV
Tuner Mode
Channel Scan
Manual Scan
Range Scan
Single Channel Scan
Source Roll
Power Roll
MTS
Audio Language
Channel Number Display
Real Channel Number
Virtual Channel Number
OSD Language
Bank Setup
Current Bank
Edit Channel Banks
Edit Source Banks
Power On Settings
OSD Time
Time Setup
Clock Settings
Set Time Zone
DST
Set Time
Set Date
Sleep Timer
Operation Time
Channel Time
Turn On Time
Turn Off Time
Power On Setup
Input Source
Turn On Channel
Volume Control
Turn On Volume
IR Band
Power Mode
LED Control
Keypad Lock
Pillow Speaker Type
TV Maximum Volume
PS Maximum Volume
Speaker Mode
Input Auto Detect
Serial Control
Clean Button
Change OSD Password
Bank Switch Password
Alarm Setup
Closed Caption Setup
IR/PS Caption Control
Panel Caption Control
Analog Closed Caption
Digital Closed Caption
Digital Caption Style
Version Information
Others
No Signal Power Off
Keypad Setup
USB Cloning
Service Reset
Parental Control
Program Block
Enable Parental Control
US TV Ratings
US Movie Ratings
Canadian English Ratings
Canadian French Ratings
Change Parental Control Password
Clean All
Parental Control Ratings Explanation
14-21
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
15
15
15
15
15
15
15
15
15
15
15
15
16
16
16
16
16
16
16
16
16
16
16
16
16
17-20
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
18, 19
18
18
18
18
18
18
18
18
19
19
19
19
19
19
19
19
19
19, 23
19, 20
19
19
20
20
20
20
20
20
20
20
20
21
21
21
21
21
21
21
21
21
21
MENUE TREE
22
PILLOW SPEAKER SETUP
23
KEY DEFINE
24
BANKS
24
VIRTUAL CHANNELS
25
EDU
25
SPECIFICATIONS
26, 27
WARRANTY
28
HealthCare Information, LLC
3
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
WARNING
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and this apparatus shall not be exposed to dripping or splashing and
no objects filled with liquids, such as vases, shall be placed on the apparatus.
Do not use this LCD TV Monitor near water. For example: avoid placing it near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a
swimming pool, etc.
This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
The mains plug of this apparatus must remain readily operable.
Advertisement:
Pour réduire le risque du feu ou de décharge électrique, n’exposez pas cet appareil à la pluie ou à l’humidité. L’appareil ne sera pas exposé à l’égoutture ou
l’éclaboussement et aucun objet remplis de liquides, tels que des vases, ne seront placés sur l’appareil.
NOTE TO CABLE TV INSTALLER
This reminder is provided to call the cable TV installer’s attention to Article 820-40 of the National Electric Code (U.S.A.). This code provides guidelines for
proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building as close to the point of the cable
entry as practical.
REGULATORY INFORMATION
This equipment generates, uses and can radiate radio frequency energy, and if not installed in accordance with this instruction manual, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the follow measures:
1. Increase the separation between the equipment and receiver.
2. Consult the dealer or an experienced radio/TV technician for help.
CAUTION
Do not attempt to modify this product in any way without written authorization from HealthCare Information, LLC. Unauthorized modification will void the
warranty of the product.
CAUTION
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type.
CAUTION
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type.
CAUTION
Use only the following UL Listed arms with the BedMate II Model numbers BM13II.
Model Arm X
CAUTION
Use only the following UL Listed power supplies with the BedMate II Model number BM13II.
PS10, PSI, WM-PSI-LB-ER, WM-PSI-LB, WM-PSI-SB, PSI 120/24, WM-PS-LB120/24E, WM-PS-LB120/24E, WM-PS-SB120/24E, WM-PS-SB120/24I
COMPLIANCE
The party responsible for this product’s compliance is:
HealthCare Information, LLC, 113 Commerce Blvd., Loveland, OH 45140, USA. Phone 513-271-8100
HealthCare Information, LLC
4
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
IMPORTANT SAFETY INSTRUCTIONS
1)
Read these instructions.
2)
Keep these instructions.
3)
Heed all warnings.
4)
Follow all instructions.
5)
Do not use this apparatus near water.
6)
Clean only with dry cloth.
7)
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8)
Do not install near any heat source such as radiators, heat registers, stoves, or other apparatus (including amplifiers)
that produces heat.
9)
Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third
prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10)
Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
11)
Only use attachments/accessories specified by the manufacturer.
12)
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold
with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
13)
Unplug this apparatus during lightning storms or when unused for long periods of time.
14)
Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
--------------------------------------------------------------------------------------------------------------------------------IMPORTANT SAFEGUARDS FOR YOU AND YOUR NEW PRODUCT
YOUR NEW PRODUCT HAS BEEN MANUFACTURED AND TESTED WITH YOUR SAFETY IN MIND. HOWEVER,
IMPROPER USE CAN RESULT IN POTENTIAL ELECTRICAL SHOCK OR FIRE HAZARDS. TO AVOID DEFEATING
THE SAFEGUARDS THAT HAVE BEEN BUILT INTO YOUR NEW PRODUCT, PLEASE READ AND OBSERVE THE
FOLLOWING SAFETY POINTS WHEN INSTALLING AND USING YOUR NEW PRODUCT, AND SAVE THEM FOR
FUTURE REFERENCE. OBSERVING THE SIMPLE PRECAUTIONS DISCUSSED IN THE MANUAL CAN HELP YOU
GET MANY YEARS OF ENJOYMENT AND SAFE OPERATION THAT ARE BUILT INTO YOUR NEW PRODUCT.
HealthCare Information, LLC
5
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
PACKAGE CONTENTS
After opening, carefully check the package contents:
 13.3” BedMate II Low Voltage LCD-TV
 IR Remotes are shipped per order.
 Manuals are shipped per order*
*The latest version of this manual can be downloaded from www.hci-tv.com
HealthCare Information, LLC
6
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
PRODUCT INTRODUCTION
HealthCare Information, LLC
7
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
PRODUCT INTRODUCTION
FRONT PANEL
RIGHT SIDE PANEL
REAR I/O PANEL
HealthCare Information, LLC
8
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
INSTALLATION
Before installing, carefully read the “Important Safeguards” section on pages 4 and 5. These mounting
instructions cover all HCI BedMate TVs. The number of cables may vary between models. RM13II sets
will typically have only a coax cable and optional RG-6 cable.
Install this TV only on an arm that has been properly mounted according to the arm and mount
manufacturer’s instructions. Make sure the arm is locked into its retracted position. If the arm cannot be
locked into its retracted position, raise the outer arm to its highest position to install the TV. Failure to
follow these steps could result in the arm raising quickly, possibly causing bodily injury.
1.
Unpack the TV from its shipping box.
2.
Remove the safety retainer nut and safety retainer from the stem at the top of the TV. NOTE:
You can not pass the safety retainer and nut over the cable connectors.
3.
Remove the side panels from the nose of the arm. There are two screws holding each side panel
in place.
HealthCare Information, LLC
9
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
Slide the stem onto the nose of the arm. Make sure the notch on the stem just below the threads fits over
the rotational stop of the arm.
4.
Place the retainer over the stem. Make sure the pin in the nose is in the small hole in the
retainer.
5.
Thread the retainer nut onto the stem and tighten.
RETAINER PROPERLY INSTALLED
6.
STEM PROPERLY INSTALLED ON
BOTTOM OF NOSE
Connect the coax cable from the TV to the coax cable from the arm using the supplies coupler.
Slightly wrench tighten both coax connectors to the coupler just enough that you can not undo
the connection by hand. DO NOT OVER TIGHTEN. 1/16 TO 1/8 TURN PAST FINGER
TIGHT IS ENOUGH. The power cable and Cat5e cables are not used with the BedMate II
and do not need to be connected.
HealthCare Information, LLC
10
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
7.
If present connect the CAT5 and power cables. (BedMate III only)
8.
Arrange the cable(s) into the nose.
9.
Reinstall the Nose covers.
10.
Plug in the power supply and proceed to setup.
HealthCare Information, LLC
11
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
BASIC CONNECTIONS
VGA
Use a male to male VGA cable to connect a computer VGA output to the PC VGA input on the back of the set. Make sure the computer
resolution is set equal to or lower than 1280 x 800. A 1/8” (3.5MM) jack is located next to the VGA input for PC AUDIO input.
Pillow Speakers/Sip-puff device
A ¼” jack is provided on rear jack panel of the set to connect a pillow speaker or sip and puff device. Only one button analog or digital
pillow speakers set for Zenith or Philips codes may be used. See pages 8, 19 and 23.
USB Port
Two USB ports are provided for playing digital media. The port on the rear I/O panel is also used for cloning settings.
RJ-12 Serial Port
An RJ-12 port is provided to allow third party devices to control the set. This port is also used for some software updates.
HDMI
An HDMI port is provided to connect to a video player. (Blue-Ray, DVD, PC)
CABLE
A standard F connector is located on the rear jack panel of the set to connect a signal coax cable to. The set is also powered from the
coax. 24VDC or 28VAC must be provided on the coax to operate the set.
Earphone/Headphone
A 1/8” (3.5MM) stereo earphone jack is located on the front lower right side of the set.
24V DC
A 24VDC jack is provided to power the television by using a 24 volt power supply.
IR Remote Special Features
EDU
Displays list of educational channels.
STATUS
Displays current channel information.
OK
Make OSD selections and displays channel list. When channel list is displayed use the up/down arrow buttons to
select a channel. Press “ENTER” to tune to the selected channel. After channel is tuned press “ENTER” again to
display information about the channel if available.
FUNCTION
Display TV status and enter function codes.
ESC
Exit OSD displays.
RED
Bank editing reset.
GREEN
Bank editing clear.
YELLOW
Bank editing copy.
BLUE
Bank editing paste.
HealthCare Information, LLC
12
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
SETUP AND OPERATION
Installing the IR Remote Control Batteries
1. Turn the IR Remote over. Press down on the arrow and slide the battery cover off the bottom.
2. Install the two included AAA batteries. The polarity is indicated on the bottom of the battery compartment. Make sure the
batteries are installed correctly.
3. Slide the battery cover back onto the remote and snap into place.
Function Codes
Setup features are accessed using function codes. You will need an IR remote control to enter function codes. To enter a function code
using an IR remote control, press the “FUNCTION” button followed by the “0” button. Set will display “ENTER PASSWORD” then
enter the function code. The following codes are available.
Note:
CODE
FUNCTION
CODE
FUNCTION
9999
10086
11111
13218
14568
15311
ACCESS TV OR DVD SETUP MENU
TURN TV ON DURING OFF HOURS
DISPLAY SOFTWARE VERSION
SHOW/HIDE DATE
TEST MODE
SET IR BAND TO BED ONE
15322
15709
15719
15729
15428
SET IR BAND TO BED 2
RESET
SERVICE RESET
CLEAR STORAGE
SERVICE MODE
See page 18 if information on changing the IR band. Press and hold the power button on an HCI IR remote for ten seconds to
change the IR remote from Band 1to Band 2 and back.
Press the setup button on the IR remote after entering the “9999” code to access the TV setup menu.
Enter function code “15428” to keep the setup menu active until the TV is turned off. You can also set the OSD Time to always to keep
the menu active. See page 17. Once this code is entered you will not have to enter the “9999” code until the set is turned off.
NOTE: Use the up/down arrow buttons to change menu section. Use the left/right arrow buttons to change selected menu item and to
access sub menus. Use the “BACK” button to go back one menu screen.
Auto Scan
Access the setup menu. Select the “TV” menu. Select “Signal Type”. Set to “Air” if signal source is from an off air antenna. Set to
“Cable” if signal source is from a cable system. Select “Channel Scan”. Press the “OK” button. Set will scan all for all analog/digital
channels and add active channels to the channel list. This will take several minutes.
Setting Date and Time
Certain features such as the “ALARM” require the proper date and time to function properly. To set the date and time:
Access the “Setup Menu”. Select “Setup”, “Power On Setting”, “Time Setup” then “Clock Setting”
Select “Time Zone” and use the left/right arrow buttons to set the time zone you are in.
Select “Daylight Saving Time”. Set to “On” if your area uses daylight savings time. Set to “Off” if your area does not use
daylight savings time.
Select “Set Time”. Use the left/right buttons to select the digit. Use the number buttons to set time. NOTE: Time is set in 24
hour format and displayed in 12 hour format.
Select “Set Date”. Use the left/right arrow buttons to select the digit. Use the number buttons to set the date. The last digit is
the day of the week. Monday is day one.
1.
2.
3.
4.
5.
Cloning
Creating Clone File
Reading Clone File
1. Insert a USB flash drive in to the side USB port.
2. Enter OSD menu. Go to Setup – Others – USB Cloning.
3. Select Save Clone File to USB. Press the “OK” button.
4. When finished (about 2 minutes) remove the USB flash drive.
1.
2.
3.
4.
Insert a USB flash drive in to the side USB port.
Enter OSD menu. Go to Setup – Others – USB Cloning.
Select Read Clone File From USB. Press the “OK” button.
When finished (about 2 minutes) remove the USB flash drive.
NOTE: USB flash drive must be formatted FAT. The clone files can be copied to multiple flash drives using a PC or laptop computer.
HealthCare Information, LLC
13
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
ADVANCED SETUP
Enter function code “9999” and press the “SETUP” button on the IR remote to enter the main setup menu. See page 22 for a full menu tree.
Use the navigation buttons to select and change menu items. Press the "BACK" button to go back one menu level, press "ENTER" or "►"
button to access the next menu level.
Video
Picture
Settings
Adjusts standard television video settings.
Picture Mode
Selects the picture mode. Each mode except user is a pre-defined setting for contrast, brightness, color
saturation, hue, and sharpness. Selections are:
User - Cinema – Sport – Vivid – Hi-Bright
If Picture Mode is set to User you can manually adjust the picture parameters.
Screen
Mode
Brightness
Adjusts brightness
Contrast
Adjusts contrast
Saturation
Adjusts level of color
Hue
Adjusts tint of color
Sharpness
Adjusts sharpness
Adjusts how the picture fills the screen. Selections are:
Auto – Normal – Letterbox – Panorama – Zoom – Dot by Dot
VGA
Settings
Auto
Picture is adjusted automatically.
Normal
Picture is displayed full screen.
Letterbox
Picture is displayed in letter box format.
Panorama
Picture is stretched at the edges to fill the screen. The middle of the picture is not stretched.
This allows the middle of the screen to look normal. Text displayed across the screen will
have a fisheye effect.
Zoom
Enlarges the picture. Edges will be lost.
Dot by Dot
Displays picture as it is received. Picture may not fill the screen or edges
may be lost.
Adjusts screen settings for using set as a computer monitor. Input must be set to VGA to adjust these
settings.
Auto Adjust
Automatically adjust screen size to match VGA input.
Horizontal
Adjusts the horizontal position of the picture.
Vertical
Adjusts the vertical position of the picture.
Clock
Adjusts sync timing. Should be left at factory default.
Phase
Adjusts VGA phase. Should be left a factory default.
Reset
Resets PC SETTINGS to factory default
Color
Sets how colors are displayed. Set for best color reproduction. Selections are:
Temperature
Standard - Warm - User - Cool
Video Noise
Reduction
Video noise reduction settings.
DNR
Sets level of video noise reduction. Selections are:
OFF - Low - Medium – Strong - Auto
MPEG Noise
Reduction
Improves the quality of pictures Settings are:
Off - Low - Med – Strong
Note: Use lowest setting possible for all noise reduction settings. Setting to a level higher than needed may cause a
reduction in picture quality.
HealthCare Information, LLC
14
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
Audio
Balance
Sets left/right balance. Only adjust with head phones.
Bass
Set the bass level.
Treble
Set the treble level.
Surround
Sound
Turn on or off surround mode. Only works with head phones.
Equalizer
Adjust audio frequency levels. Settings are:
Off – Rock – Pop – Live – Dance – Techno – Classic – Soft
Others
Miscellaneous sound settings.
Auto Volume
Control
Automatic Volume Level – Helps maintain a constant volume level when the program
volume level changes.
SPDIF
Type
Selects digital audio output format. Selections Are:
Off – PCM – Dolby Digital(AC3)
Off - No digital audio output.
PCM - Pulse Code Modulation
Dolby Digital - Dolby Surround Sound
Buzzer
Mode
Turns keypad beep on or off. When on a beep is heard when a button is pressed. Use
left/right arrow keys to turn on/off.
Pair Wireless
Audio
Pairs the TV to a Blue Tooth audio device. Select and press the “ENTER” button to pair.
HealthCare Information, LLC
15
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
TV
Tuner Mode
Switch between Cable and Antenna. Set to Cable for channels coming from a cable company and most in
house systems. Set to Air to receive off air broadcast channels.
Channel Scan
Automatically scan and add available channels to the line up.
Manual Scan
Manually Add channels.
Range Scan
Set a range of channels and type to scan.
Scan Mode
Sets type of channel to scan for. Selections are:
Analog/Digital – Analog – Digital
From Channel
Channel to start scanning at.
To Channel
Channel to stop scanning at.
Single RF Scan
Scan for a specific RF channel. Digital channels only.
RF Channel
RF channel to scan. Contact your cable company to find out what channels have Clear QAM channels
available.
Frequency Plan
Cable frequency plan. Most cable companies use STD. Contact your cable company for more
information. Selections are:
STD – IRC – HRC
Modulation
Select type of modulation used. Most cable companies use QAM 256. Selections are:
QAM 64 – QAM 256
Signal Level
Displays signal level of selected RF channel.
NOTE: To scan for a single digital channel you must know the RF channel it is broadcast on. The RF channel may not be the same
as the channel number displayed on the screen.
Channel Label
Allows a label to be assigned to all channel including analog channels. The label will be briefly displayed
when changing channels. Most digital channels will broadcast their own label that will appear when changing
digital channels. The digital channel label can be replace with a new label. To edit labels,
1. Select Channel Label from the TV OSD menu and press the “ENTER” button. A list of all channels found
during the Auto Scan will be shown and their current label.
2. Use the Up/Down arrow buttons to select the channel you wish to edit.
3. Press the “ENTER” or “OK” button twice. A virtual keypad will appear.
4. Use the arrow buttons to select characters and spaces. <= is the back space key. Press the “ENTER” or
“OK” button to select the highlighted character.
5. Select OK when finished. Press the “ENTER” or “OK” button. Press the “BACK” button to return to the
channel selection OSD.
Continue until all channel labels are entered.
NOTE: Most digital channels will have a channel label already entered. This is broadcast form the station.
You can replace the broadcast channel label with your own custom label. If a custom label is entered
it will be displayed in place of the broadcast label.
Source Roll
Turns source roll on or off. When turned on, television will loop through channels and sources.
Power Roll
Turns power roll on or off. When turned on, television will power off after changing the highest or lowest
channel number in the lineup.
HealthCare Information, LLC
16
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
MTS
Selects sound source. Selections are:
Stereo – SAP – Mono
Audio
Language
Stereo
2 Channel sound. Use with headphones
Mono
Single channel sound. Use with television speaker
SAP
Second Audio Program. Use for an alternative audio broadcast, such as a second language.
Sets the audio language to be heard. Selections are.
English – Espanola – Francis
NOTE: Most stations only broadcast one language.
Channel Number Sets channel number display parameters and turns virtual channels on and off.
Display
Real Channel
Number
Displays the real channel number determined by the RF channel for analog channels
and transmitted virtual channel number for digital channels.
Virtual Channel
Number
Turns on virtual channel numbers as entered into the TV in the Bank Edit screen.
When turned on TV channels are tuned using the virtual channels entered in the Bank Edit Screen. Order of
channels is determined by the Virtual Channel Number.
NOTE:
Virtual channel numbers allow digital channels to be assigned a whole number which can be used with
pillow speakers that do not have a “.” Or “-“ button for digital channel tuning.
HealthCare Information, LLC
17
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
SETUP
OSD Language
Sets TV menu language. Selections are:
English – Espanola – Francis
Bank Setup
Select and edit channel banks.
Current Bank
Sets current channel and source bank.
Edit Channel Banks
Select which channels are allowed for each bank.
Assign virtual channel numbers.
Edit Source Banks
Select which sources are allowed for each bank. Not all selectable sources are
available.
Note: See pages 24 and 25 for bank editing instructions and entering virtual channels.
Power On Settings
OSD TIME
Sets how long the OSD menu is displayed in seconds. Selections are:
10 s – 20 s – 30 s – 40 s – 50 s – 60 s – Always
NOTE: When Always is selected OSD will not time out. The Always settings will remain in effect
until changed or the set is turn off. When the set is turned off the OSD time will automatically be
reset to 30 seconds.
Time Setup
Set date/time, Sleep Timer and hours of operation.
Clock Settings
Set Time Zone
Set for the local time zone. Press the “ENTER” button to change. Use the left/right arrow
buttons to change. Press the “BACK” button when finished.
Daylight Savings Turns DST on or off. Use left/right arrow buttons to change.
Time
Set Time
Sets time in 24 hour format. Time is displayed in 12 hour format. Press the right arrow button
to change. Use the left/right arrow buttons to select digit to set and the number buttons to
change. Press the up or down arrow button when finished
Set Date
Press the right arrow button to change. Use the left/right arrow buttons to select digit to set.
Use the number buttons to make changes. Press the up or down arrow button when done.
Note: The forth digit is the day of the week with day 1 being Monday.
Sleep Timer
Sets the amount of time in minutes the TV will turn off in. Selections are:
Off – 5min – 10min – 15min – 30min – 45min – 60min – 90min – 120min – 180min – 240min
Operation Time Enables/disables hours of operation time. Set can only be operated between turn on and turn off
time.
Channel Time
Enables/disables time display in channel info when changing channels.
Turn On Time
Time set can be turned on. Time is displayed in 12 hour format. Press
the right arrow button to change. Use the left/right arrow buttons to select digit to set and the
number buttons to change. Press the up or down arrow button when finished
Turn Off Time
Time set will turn off. Time is displayed in 12 hour format. Press
the right arrow button to change. Use the left/right arrow buttons to select digit to set and the
number buttons to change. Press the up or down arrow button when finished.
NOTE: The set will give a warning and count down starting 2 minutes before Turn Off Time is
reached. During off time, the set can be turned on for two minutes. During this two
minutes enter Function Code 10086 to disable timer.
HealthCare Information, LLC
18
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
Power On Setup
These settings determine what the set will do when it is turned on.
Input Source
Set the source TV will use every time it is turn on. Selections are:
None – TV – FM – AV – S-Video – SD/USB – YpbPr – VGA – HDMI 1 – HDMI 2 – IPTV – USB
Note: Not all sources are available on all models. If Input Source is set to None set will turn on to same
source it was on when turned off.
Channel No.
Mode
Sets channel set will turn on to if Input Source is set to TV.
Select Turn Off Channel to have the set turn on to the same channel it was set to when turned
off.
Select User Select to set the channel the TV will turn onto every time it is turned on.
When User Select is selected a list of all available channels will appear. Use the
up/down/left/right arrow buttons to select the turn on channel. Left/right arrow buttons jump
to the next page. When you have selected the turn on channel press the “ENTER” button.
NOTE: To edit this item Input Source must be set to TV.
Volume Control
Set to on to have the set turn on to the same volume level every time. Set to off to have the set
turn on to the volume setting set when turned off.
Turn On Volume
Volume set will turn on to if Volume Control is set to On.
IR Band
Sets the IR Band set will use. Selections are:
Band 1 – Band 2 – Band 3 – Band 4
Band 1 and Band 2 are for HCI remotes. HCI remotes can be switched between Band 1 and
Band 2 by pressing and holding the power button on the remote for 10 seconds.
Band 3 and Band 4 are for universal remotes. Band 3 is for Magnavox codes and band 4 is for
Apex codes. Do not select Band 3 or Band 4 unless you have a proper universal remote. Once
Band 3 or Band 4 is selected the HCI IR remote will no longer work with the set.
NOTE: You can change the IR band using the front panel buttons by pressing the CH+ and CHbuttons at the same time.
Power Mode
Determines what the set does when power is applied. Selections are:
Off – Mode 1 – Mode 2
Off
Mode 1
Mode 2
LED Control
Normal operation
TV turns on when power is applied. Can not be turned off.
TV turns on when power is applied. Can be turned on and off.
Sets operation of front panel power LED. Selections are:
Normal – Reverse – Off_All – Off_Blk
Normal
Reverse
Off_All
Off_Blk
Keypad Lock
On when TV is on, off when TV is off.
Off when TV is on, on when TV is off.
Always off.
Always off, blinks with control input.
Limits use of front panel buttons. Selections are:
Off – Lock 1 – Lock 2
Off
Lock 1
Lock 2
All buttons function.
Only power button functions.
Only power, Vol +/- and CH +/- function.
NOTE: Keypad Lock does not affect IR remotes or pillow speakers.
HealthCare Information, LLC
19
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
Pillow Speaker Type
Sets type of pillow speaker being used. Supported pillow speakers are:
Zenith – Sip and Puff – Visitor Station – Gen4-R5 – Gen4 Interactive – Philips
Zenith
Sip and Puff
Visitor Station
Gen4-R5
Gen4 Interactive
Philips
Pillow speakers sending Zenith code.
Breath control units.
HCI Visitor Stations.
HCI custom pillow speaker.
HCI custom pillow speaker.
Pillow speakers sending Philips code
TV Maximum
Volume
Sets maximum volume allowed from the TV Speakers. This setting is used when
Speaker Mode is set to “TV Only” or “Both”.
PS Maximum
Volume
Sets maximum volume allowed from the pillow speaker. This setting is used when
Speaker Mode is set to “Pillow Speaker”.
Speaker Mode
Sets TV sound source. Selections are:
Off – TV – Pillow Speaker – Both
Off
TV
Pillow Speaker
Both
All external sound if off. Headphones will still have sound.
Sound form TV speaker only.
Sound from pillow speaker only.
Sound from both TV and pillow speaker.
Input Auto Detect
When set to “On” TV will return to previous source if the current source has no signal.
Serial Control
Turns serial control on/off. Serial control is via the RJ-12 port on the rear I/O panel.
Clean Button
Enables/Disables the CLEAN button on the front panel. When the CLEAN button is pressed the front
panel buttons are disabled for 30 seconds to allow the screen to be cleaned.
Change OSD Password
Bank Switch
Password
Change setup password. Default is 9999.
When off the current bank can be changed by pressing the B button on the IR. When set
to on requires Function Code 9999 to be entered before the current channel bank can be changed.
Note: If the Setup Password has been changed then the new password must be used in place of “9999”
Alarm Setup
Up to 7 alarms can be set to turn the set on or off at a specific time. See page 23 for instructions on setting the
alarms.
Closed Caption Setup Closed Caption (CC) setup.
IR/PS Caption
Control
Set to match the CC/Mute button setup of the IR control or pillow speaker. Setting tells the set if the IR
Control or Pillow Speaker has a CC button only, Mute button only or Both a CC button and a Mute
button. Set to match the device patient will be using to control the set. Selections are:
Mute Only – CC Only – CC and Mute
Mute Only
IR control or Pillow Speaker has only a Mute button. Mute button will select:
CC On-Mute On, CC On Mute Off, CC Off-Mute On, CC Off- Mute Off
CC Only
IR control or Pillow Speaker has only a CC button. Mute button will select:
CC On-Mute On, CC On Mute Off, CC Off-Mute On, CC Off- Mute Off
CC and Mute
Panel Caption
Control
IR control has both CC and Mute button. CC button will turn CC on and off. Mute button
will turn Mute on and off.
Determines How the CC button on the front panel functions. Selections are:
Mute Only – CC Only – CC and Mute
Mute Only
CC button turn mute on and off. No CC control.
CC Only
CC only, no mute control. Selections are
CC Off – CC On – CC On Mute
NOTE: Mute command can only come from IR Remote or pillow speaker control.
CC and Mute
CC button controls both CC and Mute. Each press cycles to the next selection. Selections
are:
CC On-Mute On, CC On-Mute Off, CC Off-Mute On, CC Off- Mute Off, CC On Mute
HealthCare Information, LLC
20
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
Analog Closed
Captions
Settings for viewing Closed Captions on analog channels. This setting determines which CC or Text
service is viewed when CC is on. Settings are:
Off – CC 1 – CC 2 – CC 3 – CC 4 – Text 1 – Text 2 – Text 3 – Text 4
Off
CC 1-4
Text 1-4
No Closed Captions are displayed on analog channels.
Standard Closed Captions. CC 1 is used most often.
Standard text services. Most stations do no broadcast text services.
Note: If a Text service is selected and CC is turned on a black box will appear on the screen even if no text
is available.
Digital Closed
Caption
Sets which Closed Caption service will be displayed.
Selections are
Off - Service1 – Service2 – Service3 – Service4 – Service5 – Service6
NOTE: As with analog channels not all stations or shows will contain closed captioning.
Not all caption services may be available.
Digital Caption
Style
Sets digital CC font style. You can have the captions shown “As Broadcast” or select your own
“Custom” font styles.
As Broadcast
Custom
Uses font attributes as broadcast.
Allows user to set font attributes.
When Digital Caption Style is set to custom the following font styles can be selected.
Font Size
Sets digital CC font size to Small, Standard or Large
Font Color
Sets font color. Available colors are:
Black – White – Green – Blue – Red – Cyan - Yellow – Magenta
Font Opacity
Sets font transparency to Solid, Translucent or Transparent.
CC Background
Opacity
Sets digital CC background transparency. Selections are:
Default – Solid – Flashing – Translucent – Transparent
CC Background
Color
Sets digital CC background color. Available colors are:
Default - Black – White – Red – Green – Blue – Yellow – Magenta – Cyan
NOTE: Make sure CC Color and CC Background Color are different. If they are the same you will not be
able to see the closed captioning.
Version Info.
Displays hardware and software versions. Version information can also be displayed by entering function
code 1111 without entering the OSD menu.
Others
No Signal
Power Off
If set to on and signal is lost the set will automatically turn off after
Keypad
Changes what the front panel buttons do. See page 24 for information on redefining front
Redefinition panel button functions.
USB Cloning Copy channel line up and OSD menu setting from one TV to other TVs using a USB flash drive. USB
flash drive must be formatted FAT.
Save Clone File
To USB
Writes clone files to USB flash drive.
Load Clone File
From USB.
Reads clone files from USB flash drive
NOTE: See page 13for full cloning procedure.
Service Reset Intended for factory use only. Resets all OSD menu items to factory default values. Clears all channel
information and sets all analog channels as active.
HealthCare Information, LLC
21
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
PARENTAL
Parental control parameters to restrict viewing based on shows rating. Default password is 9999.
Selecting ratings to block is the same for all four rating screens. Use the left/right/up/down arrow buttons
to select the highest rating you wish to allow. Press the “ENTER” button to select the rating. All higher
ratings will be automatically selected. To deselect a rating, select it and press the “ENTER” button.
Higher rating will not automatically be deselected. Some ratings have sub-ratings. You can block or allow
individual sub-ratings. Select the box under the “A” column to select/deselect all ratings in that row.
Program Block
Enable Parental Control
Set to on to enable parental control on. Set to off to disable parental control.
US TV Ratings
Use this screen to restrict rating for TV shows broadcast in the United Stated.
US Movie Rating
Use this screen to restrict rating for movies in the United Stated.
Canadian English Ratings
Use this screen to restrict rating for TV shows broadcast in English speaking areas of Canada.
Canadian French Ratings
Use this screen to restrict rating for TV shows broadcast in French speaking areas of Canada.
Open V-Chip
Factory access only.
Block Unrated
When set to “On” any shows that do not have a rating will be blocked.
Change Password
Change the password used to enter the parental control setup.
Clean All
Reset TV back to default settings and clear all channels.
TV SHOW RATINGS
US TV Shows
US Movies
TV-Y
Content appropriate for all ages.
G
General Audiences
TV-Y7
Content may not be suitable for children under 7 years of age.
PG
Parental Guidance Suggested
TV-G
Content may not be suitable for children under 7 years of age.
PG-13
Parents Strongly Cautioned
FV
R
Restricted
Content may not be suitable for young children.
NC-17
No one under 17
D
L
S
V
FV
X
Strong sexual situations
TV-PG
TV-14
Suggestive Dialogue or Drama
Mild Coarse Language
Mild Sexual Situations
Moderate Violence
Fantasy Violence
Content may not be suitable for children under 14 years of age.
D
L
S
V
FV
TV-MA
Contains Fantasy Violence
Highly Suggestive Dialogue or Drama
Coarse Language
Moderate Sexual Situations
Intense Violence
Fantasy Violence
Contend intended for mature audiences only.
L
Coarse Language
S
V
Moderate Sexual Situations
Intense Violence
Canadian English Ratings
Canadian French Ratings
C
Children
G
General
C8+
Children Over 8 years of age
8 ans+
General – Not suitable for young children
G
General
13 asn+
13 years of age and older
PG
Parental Guidance
16 ans+
16 years of age and older
14+
Over 14 years of age.
18 ans+
18 years of age and older
18+
Adults over 18 years of age.
HealthCare Information, LLC
22
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
MENU TREE
HealthCare Information, LLC
23
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
PILLOW SPEAKER OPERATION
See page 19 for information on pillow speaker type selection.
See pages 19 to disable the TV’s internal speakers or turn on pillow speaker sound.
The BM13II has a ¼” jack for pillow speaker connection. A one button analog pillow speaker, digital pillow speaker set for Zenith or
Philips code, HCI Visitor station or a Sip and Puff device can be used.
Pin Out
SIP and Puff Connections
Tip
Volume/Mute
Ring
Channel/Power
Sleeve Common
Sip and Puff control is via mechanical switch closure between Tip or Ring and Common. There is no audio available from the pillow
speaker jack when sip and puff is selected.
Starting with the set off and switch closure between Ring and Common will turn the set on. Once set is on a momentary closure will
change the channel one channel. Maintaining the switch closure for about 3 seconds will change direction of the change. For instance
if channel change was up to the next higher channel the direction will change to down and change to the next lower channel. The
change is indicated on the screen. Holding the closure for about 5 seconds will turn the set off. A single button pillow speaker will also
function this way.
A switch closure between Tip and common will cause the volume to change. Maintaining the switch closure for about 3 seconds will
change direction of the change. For instance if volume change was up the direction will change to down. The change is indicated on
the screen. Holding the closure for about 5 seconds will mute the sound. The next closure will un-mute the sound. A sip and puff
device must be a two function device to control volume. Single function devices can only control channel change and power.
NOTE: When the set is set for Sip and Puff operation audio is not available from the pillow speaker jack.
ALARMS
There are seven alarms that can be programmed. Select Alarm Setup under the Setup menu and press the “ENTER” button. Use the
up/down arrow buttons to select the alarm number you wish to edit. Press the right arrow button to edit the selected alarm. Alarm
settings override turn on settings. Alarm settings are:
Alarm Mode
Determines what the alarm does. Selections are:
None – Daily On – Daily Off – Power On – Power Off
None
Alarm off.
Daily On
Turn on at set time every day.
Daily Off
Turn Off at set time every day.
Power On
Turn on at set time once.
Power Off
Turn off at set time once.
Time
Sets time alarm will occur. “Alarm Mode” can not be set to “None”.
Date
Sets date alarm will occur. “Alarm Mode” must be set to “Power On” or “Power Off”.
Input Source
Source set will use when turned on by alarm. Selections are:
TV – FM – AV – S-Video - SD/USB - YPbPr – VGA – HDMI 1 – HDMI 2 – IPTV - USB
Channel No.
Selects alarm turn on channel. “Input Source” must be set to TV to edit this selection.
Volume
Alarm turn on volume. Set to “0” to volume setting when set was turned off.
NOTE: Date and Time must be properly set for the alarms to function at correct time. See pages 13 and 17 to set date and time.
HealthCare Information, LLC
24
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
KEY DEFINE
The functions of some front panel buttons can be redefined. To change the functions:
1.
Enter the setup menu.
2.
Select “Keypad definition” in the “Others” menu and press the right
arrow button.
3.
Use the up/down arrow buttons to select the button you wish to change.
Not all buttons can be changed. There are 9 buttons that can be changed.
See diagram for button locations.
4.
Use the right and left arrow button to change the function.
5.
Repeat steps 2 and 3 for all buttons you wish to change.
6.
Press the "BACK" button when finished.
BANKS
Banks, also known as tiers, allows the set to have up to 4 different channel lineups that can be easily switched to without
reprogramming the set. The banks are useful in rental applications where one bank can be only free channels and the three remaining
banks can include various premium channels. Another use would be for TV in different areas. All TVs could be programmed the same
with Bank 1 setup for patient rooms, Bank 2 setup for staff locations, bank 3 for waiting areas and bank 4 for pediatrics.
Sample Bank setup.
Bank Editing Special Keys
Red
Reset Turn all channels on in selected bank.
Green Clear Turn all channels off in selected bank.
Yellow Copy Copy current bank.
Blue
Paste
Paste copied content into selected
bank.
In the above example if the TV was set for:
Bank 1 the channel lineup would be 8, 9-1 and 11.
Bank 2 the channel lineup would be 9-2, 10 and 12-1
Bank 3 the channel line up would be 8, 9-2, 11, 12 and 12.1
Bank 4 the channel lineup would be 8, 9-1, 9-3, 10 and 11
Channel 3, Bank 3 is selected for editing.
NOTE:
The current bank can be selected with the “B” button on the IR remote control. If Bank Switch Password is set to on you
must first enter Function Code 9999 to change the current bank setting.
SOURCE BANK
Source Bank lets you select which input sources are available based on the current Bank setting. Source Bank setup works the same as
Bank setup. Available sources for the 13.3 inch set are TV, SD/USB, FM and VGA. If a source is not in the lineup for the current
Bank (box unchecked) that input source will not be available when the Input or Source buttons are pressed.
HealthCare Information, LLC
25
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
VIRTUAL CHANNELS
Using the virtual channel mapping feature of your HCI television will allow you to make a custom channel lineup. You can assign both
analog and digital channels a virtual channel number different from the actual channel number. Virtual channel numbers must be whole
numbers.
Virtual channels allow each channel to be assigned a whole digit number even if it is a digital channel. When Virtual Channels are
turned on the TV channel line up will be based on the assigned Virtual Channels. The TV will tune channels using the virtual number.
The virtual number will be displayed as the channel number but the TV will actually tune to the channel the virtual number was
assigned to. See page 25 for instructions on setting the virtual channel number.
Another use for virtual channels is when you have digital channels but no period or dash button on the pillow speaker. If you have a
digital channel such as 12.1 you can assign a virtual channel number such as 6. (Any unused number can be used.) Now to tune to
channel 12.1 you enter 6 on the pillow speaker. The TV channel number display reads 6 but the set tunes to channel 12.1.
The example shown below shows how channels are tuned based on the 6 channels shown and if Virtual Channel is on or off.
NOTES:
To aid setting up virtual channels you can turn Real Channel Display on in the Advance Setting menu. This will show both
the Virtual Channel and real channel number on the OSD channel display. See page 16.
If Virtual CH No. is set to On only channels that have a virtual channel number assigned will be available regardless of the
bank setting. In this example real channels 9-2 and 9-3 will not be available if Virtual Channels are turned on.
EDU (Education Channels)
Pressing the EDU button will bring up a list of channels assigned as education channels. Once the EDU channel list is displayed,
use the up/down arrow buttons to select one of the channels and press the enter button to tune to the selected channel. To add a
channel to the EDU list:
1.
2.
3.
4.
Tune to the channel you wish to add.
Press the EDU button
Press the down arrow button until the selection box is below the last channel showing.
Skip this step if this is the first channel being added.
Press the “OK” button.
HealthCare Information, LLC
26
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
SPECIFICATIONS
DIMENSIONS
HealthCare Information, LLC
27
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
GENERAL SPECIFICATIONS
Cabinet Color
Standard color USA– Cool Grey,
Standard color Canada – Tan with maple leaf symbol.
Custom colors available.
Dimensions
Weight (Lbs)
Shipping Weight (Lbs)
Shipping Dimensions (mm)
L15.35 x W2.58 x H10.04 Inches
8.5 Lbs
12.8 Lbs
(L) 23.78 x (W) 10.04 x (H) 20.35 Inches
Power Source
Consumption
28V AC 60Hz / 24 V DC
20W MAX
Video Screen Size (mm)
Display Type
Resolution
Color Depth
Aspect Ratio
Luminance (brightness)
Contrast Ratio
Viewing Angle (vert & horz)
Response Time
Digital Progressive Scan
Black Level Expansion
White Level Expansion
Display Modes
Quick Video Setup
10.55 (H) x 7.04 (V) Inches
LCD with LED backlight
1280 x 800 pixels
262144 colors
16:10
275cd/m 2
600:1
90 (H), 15 Up (V), 35 Down (V) Degrees
8 ms
Yes
Yes
Yes
ATSC, NTSC, PC, HDTV
Standard, Movie, User, Dynamic
Audio On-Screen Equalizer
MST
Audio Power to Speaker
Quick Audio Setup
Level
Audio Control
Yes
Mono, Stereo, SAP
5W
Standard, Soft, User, Dynamic
Programmable Maximum Levels
TV Speaker, Pillow Speaker, Both, Off
Inputs
Input RF Signals
Physical Inputs
ATSC, Clear QAM64, Clear QAM256, NTSC (VHF/UHF/CATV/FM)
USB, USB, VGA, Serial, HDMI, Pillow Speaker 1/4" Jack, 24VDC Jack
Outputs
Stereo headphone and pillow speaker audio.
Pillow Speaker Type
Digital Media
Zenith, Sip & Puff, Visitor Station, Gen4 R5, Gen4 Inter, Philips and 1 Button Analog.
Video Formats Supported
Photo Formats Supported
Music Formats Supported
MPEG - 1, MPEG - 2, MPEG - 4, WMV, WMV - HD, AVI
JPEG, BMP, GIF, PNG
MP2, MP3, WMA, WMA - Pro
Special Features
Education
Power supply
Power on Settings
Menu Languages
Parental Control
Sleep Timer
Alarm
Clock
Closed Captions
Closed caption Formats
Bed Selection
IR Remote
Support for Universal Remote
Setup Menus
Keypad Disable
Cloning
Power on /off time
10 Channels
Built In
Input, Channel, Volume
English, Spanish, French
V - Chip
Yes
7 Programmable On / Off Times
Real Time Clock with Battery Backup
On, Off, On with Mute
CC1 - 4, Text1 - 4, Digital Service 1-6
1, 2 Plus support for Universal Remotes
User Programmable for Bed 1 or 2
Yes
Password protected (remote required)
Off, Power Only, Power Channel and Volume
Copy All Settings from one TV to Another via USB Flash Drive
Yes
Approvals
FCC (B), C-UL
Warranty
Two Years Parts & Labor
HealthCare Information, LLC
28
----------------------------------------------------------------------------------BedMate II OPERATIONS MANUAL
WARRANTY
HCI Television product Limited Warranty
HCI warrants, to the original purchaser only that all new HCI televisions (excluding any equipment
manufactured by others and included in HCI shipment) are free from defects in material for a period of two
years from the date of shipment.
The dealer your product was purchased through must receive notice of a defect or malfunction occurring
during the warranty period, HCI will repair or replace goods returned to its Loveland, Ohio office, at its
discretion, free of charge to the original purchaser, the whole or any component part of any product
manufactured by HCI found to be defective.
As a condition to obtaining warranty service, notification must be given to the dealer the product was
purchased through within at least 10 days after defect is first observed. Repair of product requires it to be
shipped to HCI in Loveland, Ohio. All shipping and freight charges to HCI shall be paid for by the
customer and will not be accepted without a Return Authorization Number (RA#). The dealer can provide
you information on how to obtain the RA#.
This warranty does not apply to any HCI products subjected to improper use, negligence or accident; nor to
tampering, alterations, or repairs by others, without HCI’s written prior notice. For more information
pertaining to this warranty, please contact the dealer you purchased your product from.
HCI’s liability under this warranty is limited to repair or replacement of defective products and parts as
provided above. HCI shall not be liable for incidental or consequential damage
HealthCare Information, LLC
29
HCI ALSO OFFERS 22”, 26”, 32, & 42” SIZES
TM
©Copyright 2011, HealthCare Information,