Installation and Operation Manual TANDOOR OVENS Commerical European Models Round, Square, Octagonal and Barrel Models wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa TANDOOR 31" AND 35" WS-GFT-31 WS-GFT-35 WS-GFT-CUS woodstone-corp.com t.+1.360.650.1111 f.+1.360.650.1166 Revised January 2014 Doc no: M0054.00 TABLE OF CONTENTS Tandoor Installation and Operation Manual TABLE OF CONTENTS TANDOOR���������������������������������������������������3 CAUTIONS AND WARNINGS �������������������������4 GFT-31 SPECIFICATIONS �����������������������������5 GFT-35 SPECIFICATIONS �����������������������������6 CLEARANCES & VENTING�����������������������������7 GAS SPECIFICATIONS�����������������������������������8 OPERATION�������������������������������������������������9 LIMITED WARRANTY ���������������������������������11 An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 2 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com TANDOOR TANDOOR Tandoor Installation and Operation Manual INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE TANDOOR GAS-FIRED TANDOOR OVEN WS-GFT-31 (ROUND, SQUARE AND OCTAGONAL), WS-GFT-35 (ROUND, SQUARE, OCTAGONAL) CE MODELS ADDITIONAL COPIES AVAILABLE UPON REQUEST Square model (shown with optional utensil rails, pan rail w/ pans and shelf) Octagonal model An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 Barrel model Round model wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com 3 CAUTIONS AND WARNINGS Tandoor Installation and Operation Manual INSTALLATION AND OPERATING INSTRUCTIONS FOR THE WOOD STONE GFT-31-(RND, SQR, OCT)-(NG, LP), GFT-35-(RND, SQR, OCT)-(NG, LP) TANDOOR OVENS RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone-corp.com. For prompt responses to service/maintenance questions, call your local distributor. READ ALL INSTRUCTIONS BEFORE INSTALLING AND USING THIS APPLIANCE Please read this entire manual before you install the oven. Failure to follow instructions may result in property damage, bodily injury or even death. Contact your local building or fire officials about restrictions and installation inspection in your area. It is recommended that this oven be installed, maintained and serviced by authorized professionals. IMPORTANT: Consult your local gas supplier for a statement outlining a procedure to be followed in the event you smell gas. Post the statement in a prominent location. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Also, always keep the area under and around this appliance free and clear of any and all combustible materials. WARNING: Improper installation, adjustment, alteration, service or maintenance can result in property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. DO NOT THROW THIS MANUAL AWAY Wood Stone's gas-fired Tandoor was tested and approved by Intertek Testing Services, to the requirements of BS-EN 203-1:2005 and BS EN 203-2-1:2005 for Safety of Catering Equipment. An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 4 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com G G G GFT-31 SPECIFICATIONS Tandoor Installation and Operation Manual O 12" 300mm O 12" 300mm O 12" 300mm Opening Opening Opening WS-GFT-31 (ROUND, OCTAGONAL AND SQUARE MODELS) Plan view (Round) 30 3/4" Front view (Round) 30 3/4" 780mm 780mm G G G G G Air intake: Do not facade or cover over 30 3/4" 780mm 30 3/4" 780mm 30 3/4" 780mm 21" 530mm 30 3/4" 780mm Shipping weight: 431 Kg (750 lbs.) G 37 3/4" 960mm 21 1/2" 550mm 31" 790mm O 12" 300mm Opening 12" O 300mm Opening Side view (Round) 21" 530mm 30 3/4" 780mm 30 3/4" 780mm 21" 530mm G G Note: Side and front G PART #: WS-GFT-31-RND view dimensions DATE: 10/14/2013 are the same for 37 3/4" 960mm 21 1/2" 550mm Bellingham, WA 360/650-1111 www.woodstone-corp.com 37 3/4" 960mm DIMENSIONS ARE IN INCHES TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2° UNLESS NOTED OTHERWISE 31" 790mm 31" 790mm 12 3/4" AN ONGOING PROGRAM OF PRODUCT 320mm IMPROVEMENT 6MAY 1/4"12" REQUIRE US TO CHANGE SPECIFICATIONS O 300mm 160mm Opening WITHOUT NOTICE. 6 1/4" O 12" 300mm Opening 21 1/2" 550mm SHEET: 1 of 1 the DWN BY: bena Round, Square and 31" Tandoor. All Shape Octagonal models. General Arrangement LEGEND: 160mm Plan view (Octagonal) 30 3/4" 780mm /4" mm 12 3/4" 320mm Opening 12" O 300mm Opening Plan view (Square) 0 3/4" 80mm 12 3/4" 320mm 6 1/4" 160mm O 12" 300mm O 12" 300mm Opening 12" O 300mm Opening THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION ANY REPRODUCTION OR USE IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS UTILITY SPECIFICATIONS PROHIBITED GAS INLET: 1/2" NPT G 40,000 BTU, NG 40,000 BTU, LP Gas: 19mm (3/4") BPT gas inlet (female threaded) See gas ratings in the GAS SPECIFICATIONS section of this manual. Gas type must be specified when ordering. Gas connection should SHEET: be made an approvedREV: flexible connector 1 of using 1 PART #: WS-GFT-31-RND and the unit must be restrained in accordance with all relevant REV: local and 1 of 1 DATE: PART #: WS-GFT-31-RND 10/14/2013 DWNSHEET: BY: bena 21 1/2" national 550mm codes. Gas connection is made beneath unit at rear. DATE: 10/14/2013 DWN BY: bena Venting 31" Tandoor. All Shapes This appliance be installed an exhaust hood, in accordance 31" must Tandoor. Allunder Shapes General Arrangement with all relevant local and national codes, and in a manner acceptable to Arrangement the authorityGeneral having jurisdiction. 21" 530mm \\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft G G Bellingham, WA 360/650-1111 www.woodstone-corp.com Bellingham,DIMENSIONS WA 360/650-1111 www.woodstone-corp.com ARE IN INCHES 1 TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2° DIMENSIONS ARE IN INCHES 12 3/4" UNLESS NOTED OTHERWISE 320mm ±2° TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR O 12" 300mm AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT UNLESS 6 1/4"NOTED OTHERWISE Opening MAY REQUIRE US TO CHANGE SPECIFICATIONS 160mm AN ONGOINGWITHOUT PROGRAMNOTICE. OF PRODUCT IMPROVEMENT LEGEND: MAY REQUIRE US TO CHANGE SPECIFICATIONS LEGEND: THE INFORMATION CONTAINED IN NOTICE. THIS DRAWING IS THE WITHOUT SOLE PROPERTY OF WOOD STONE CORPORATION THE INFORMATION CONTAINED IN THIS DRAWING IS THE ANY REPRODUCTION OR USE IN PART OR AS A WHOLE SOLE OF WOOD STONE CORPORATION WITHOUT THEPROPERTY WRITTEN PERMISSION OF WOOD STONE IS ANY REPRODUCTION OR USE IN PART OR AS A WHOLE 21" PROHIBITED 530mm WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS PROHIBITED GAS INLET: 1/2" NPT G 40,000 BTU, NG GAS INLET: 1/2" NPT 40,000 BTU, LP G 40,000 BTU, NGwood stone corporation An ongoing of product improvement may require us to change \\woodstone.net\dfs\CAD\0 Pn\WS program Top Level\WS-GFT-31_General_Arrangement-1.dft oodstone-corp.com 1801 w. bakerview rd. bellingham, wa 98226 usa 40,000 BTU, LP \\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-31_General_Arrangement-1.dft t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com specifications without notice. WS-GFT-CE, Revised January 2014 PART #: WS-GFT-31-RND 21 1/2" 550mm DATE: 10/14/2013 1 SHEET: 1 of 1 DWN BY: bena REV: 1 5 G G G GFT-35 SPECIFICATIONS Tandoor Installation and Operation Manual O 13" 330mm O 13" 330mm Opening Opening O 13" 330mm Opening WS-GFT-35 (ROUND, OCTAGONAL AND SQUARE MODELS) 34 3/4" Plan view (Round) 880mm Front view (Round) 34 3/4" 880mm 34 3/4" 880mm 34 3/4" 880mm 24 3/4" 630mm 34 3/4" 880mm Air intake: Do not facade or cover over 34 3/4" 880mm G G G G G Shipping weight: 431 kg (950 lbs.) G 40 3/4" 1040mm 24 1 620m 33 3/4" 860mm Opening O 13" 330mm Opening Opening O 13" 330mm Opening O 13" 330mm Opening O 13" 330mm Opening Plan view (Square) 34 3/4" 880mm 34 3/4" 880mm 24 3/4" 630mm 24 3/4" 630mm G 40 3/4" 1040mm 40 3/4" 1040mm 33 3/4" 860mm 33 3/4" 860mm Bellingham, WA 360/650-1111 www.woodstone-corp.com 24 1/2" 620mm AN ONGOING PROGRAM OF PRODUCT IMPROVEMENT MAY REQUIRE US TO CHANGE SPECIFICATIONS 6 1/4" 160mm WITHOUT NOTICE. LEGEND: THE CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION ANY REPRODUCTION OR USE IN PART OR AS A WHOLE 24 3/4" THE WRITTEN PERMISSION OF WOOD STONE IS WITHOUT UTILITY SPECIFICATIONS 630mm PROHIBITED 34 3/4" 880mm GAS INLET: 1/2" NPT G 40,000 BTU, NG 40,000 BTU, LP Gas: 19mm (3/4") BPT gas inlet (female threaded) See gas ratings in the GAS SPECIFICATIONS section of this manual. Gas type must be specified when ordering. REV:connector Gas connection should be made using 1 of 1an approved flexible PART #: WS-GFT-35-RND SHEET: REV: local and 24 1/2" 1 of 1 PART #: WS-GFT-35-RND SHEET: and the unit must be restrained in accordance with all relevant DATE: 10/14/2013 620mm DWN BY: bena DATE: 10/14/2013 national codes. Gas connection made benabeneath unit at rear. DWNisBY: Venting 35" Tandoor. All Shapes 35" must Tandoor. Allunder Shapes This appliance be installed an exhaust hood, in accordance General Arrangement with all relevant local andArrangement national codes, and in a manner acceptable to General the authority having jurisdiction. LEGEND: \\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-35_General_Arrangement-1.dft G Bellingham, WA 360/650-1111 www.woodstone-corp.com Bellingham, WA 360/650-1111 www.woodstone-corp.com 11 DIMENSIONS ARE IN INCHES TOLERANCES: LINEAR ARE ±1/2 IN [±10mm], ±2° DIMENSIONS INCHESANGULAR 14 1/4" UNLESS NOTED OTHERWISE 360mm ±2° TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR O 13" 330mm UNLESS NOTED OTHERWISE Opening AN ONGOING PROGRAM PRODUCT IMPROVEMENT 6 1/4" OF 160mm MAY REQUIRE US TOOF CHANGE SPECIFICATIONS AN ONGOING PROGRAM PRODUCT IMPROVEMENT WITHOUT NOTICE. MAY REQUIRE US TO CHANGE SPECIFICATIONS LEGEND: NOTICE. THE INFORMATIONWITHOUT CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION THE INFORMATION CONTAINED IN THIS DRAWING IS THE ANY REPRODUCTION OR USESTONE IN PART OR AS A WHOLE SOLE PROPERTY OF WOOD CORPORATION WITHOUT THE WRITTEN STONE IS 24 3/4" ORPERMISSION ANY REPRODUCTION USE IN PART OF ORWOOD AS A WHOLE 630mm PROHIBITED WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS PROHIBITED GAS INLET: 1/2" NPT GGAS40,000 INLET:BTU, 1/2" NG NPT 40,000 BTU, G 40,000 BTU, NG LP wood stone corporation 40,000 BTU, LP \\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-35_General_Arrangement-1.dft \\woodstone.net\dfs\CAD\0 Pn\WS Top Level\WS-GFT-35_General_Arrangement-1.dft An ongoing program of product improvement may require us to change specifications without WS-GFT-35-RND notice. WS-GFT-CE, Revised January 2014 PART #: DATE: 10/14/2013 SHEET: 1 of 1 DWN BY: bena 24 1/2" 620mm 35" Tandoor. All Shapes 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com REV: 1 DWN BY: bena 35" Tandoor. All Shape 6 1/4" 160mm INFORMATION Plan view (Octagonal) SHEET: 1 of 1 General Arrangement Opening Opening CHES Note: Side and front view dimensions are the same for the PART #: WS-GFT-35-RND Round, Square and DATE: 10/14/2013 24 1/2" 620mm Octagonal models. DIMENSIONS ARE IN INCHES TOLERANCES: LINEAR ±1/214[±10mm], ANGULAR ±2° 1/4" 13" O 330mm UNLESS NOTED 360mm OTHERWISE O 13" 330mm 6 ne-corp.com 6 1/4" 160mm 14 1/4" 360mm Side view (Round) G G G 14 1/4" 360mm O 13" 330mm O 13" 330mm INSTALLATION CLEARANCES & VENTING Tandoor Installation and Operation Manual ! WARNING: Do not pack required air space (clearance) with insulation or other materials. When non-combustible building materials contact the body of the oven, the clearances to combustibles are transferred to those non-combustibles. INSTALLATION CLEARANCES The Wood Stone gas-fired Tandoor must be installed with at least 25mm (1") side clearance to combustible construction. Install the unit on a non-combustible floor, or one provided with a non-combustible covering that extends at least 92mm (36") in all directions. Any combustible construction above (overhanging) the appliance should be protected in a manner acceptable to the authority having jurisdiction. Combustible construction overhanging the appliance should be protected in a manner acceptable to the authority having jurisdiction. ENCLOSURES If the appliance is enclosed, provisions should be made so that it can easily be removed from the enclosure. 25mm (1") side clearance to combustible construction Shaded area must be left unobstructed for critical combustion air and easily accessible for removal of the drip pan and operation of the pilot safety valve. If this area must be covered, the cover should be easily removable and heavily perforated. Install on a noncombustible floor, or one protected in a manner acceptable to the authority having jurisdiction, extending 92mm (36") in all directions. VENTING The Wood Stone gas-fired Tandoor must be installed under an appropriate grease rated exhaust hood. Refer to local and/ or national codes for hood specification requirements. The hood must be designed for the removal of the combustion products of gas, as well as the cooking vapors related to the intended use of the oven. Make up air must be provided as necessary for the proper operation of the ventilation system. Some jurisdictions may require that the Tandoor be interlocked to the hood ventilation system to prevent operation of the appliance when the ventilation system is not turned on. If an interlock is required, use an approved gas solenoid (supplied and installed by others), wired so that the gas supply to the appliance is turned off whenever the ventilation system is turned off. An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com 7 GAS SPECIFICATIONS Tandoor Installation and Operation Manual GAS CONNECTION The gas connection is made at the lower rear of the appliance. See next page for details. This appliance is equipped with casters; it must be installed using the casters supplied with an approved gas connector/ quick disconnect device in accordance with all pertinent national and local regulations. It must also be installed with restraining means to guard against transmission of strain to the connector. IMPORTANT: The gas supply to this appliance should be equipped with an individual appliance shutoff valve that is capable of completely isolating the appliance from the main gas supply. This valve should be installed in such a manner as to be readily accessible to the operator of the appliance. The Wood Stone gas-fired Tandoor is equipped with a 19mm (3/4") BPT female gas connection, located on the underside of the rear of the unit. Anchor points for the restraining means are provided on the underside of the Tandoor; these are holes punched in the rear portion of the drip/debris pan rails. GAS RATINGS Model Input (kW) Gas Group Inlet Pressure (mbar) Gas Pressure at Valve Outlet (mbar) WS-GFT-31 and WS-GFT-35 11.7 I2H 20 11.7 I2L 25 11.7 I2E 20 14.2 I3+ 28-30/37 11.7 I3P 30/37/50 14.2 I3B/P 28-30/37 14.2 I3B/P 50 10 10 10 25 25 25 25 THIS APPLIANCE IS NOT FOR USE WITH SOLID FUEL GAS CODE LIMITATIONS The installation of this appliance must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, the Natural Gas installation Code CAN/CGA-B149.1 or the Propane Installation Code, CAN/ CGA-B149.2, as applicable. The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied by others) during any pressure testing of the gas supply piping system at test pressure, equal to or less than 1/2 psi (3.45 kPa). An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 8 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com OPERATION OPERATION Tandoor Installation and Operation Manual PILOT LIGHTING PROCEDURE Turn the Temperature Control Knob on the top of the unit to the OFF posiiton before attempting to light the pilot. 1. Turn the Gas Control Knob on the safety valve to the PILOT position. 2. Push down on the Gas Control Knob and light the pilot immediately by pressing the red button of the spark igniter. Press the igniter every 2 seconds until a pilot flame is established. Hold the Gas Control Knob down for one full minute after lighting the pilot. 3. Release the Gas Control Knob – the pilot flame should continue to burn. If the pilot flame does not remain lit, turn the gas control valve to the OFF position, wait 5 minutes, and then repeat the steps above. 4. Once pilot is established, turn the Gas Control Knob on the safety valve (counterclockwise) from the PILOT to the ON position. NOTE: failing to turn the gas control knob to the full ON position will reduce the flow of gas and could result in poor ignition of the main burner. 5. Use the Temperature Control Knob on top of the Tandoor to control the height of the cooking flame. For Barrel models, temperature control is located on the control box at the front end of the oven. Lid Plan view Front view Temperature Control Knob Drip/ debris pan Gas Control Knob FIRST FIRING The first time the Tandoor is fired, the heat-up should be slow and steady. Hold the burner at a very low flame (Temperature Control Knob set at “1” on models that are marked) for at least 8 hours with the lid on. Following this procedure will safely saturate the chamber with heat. You may notice some small "crazing" cracks in the ceramic chamber after a few heat-ups and cool-downs. Don't be alarmed as this is normal and will not affect the longevity or performance of the Tandoor. Spark Igniter Button (Red) Temperature Control Knob First firing setting An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com 9 OPERATION Tandoor Installation and Operation Manual DAILY OPERATION At the start of the day, the Tandoor will need to be heated for approximately 60–90 minutes at full flame height (5) with the lid on. Temperature Control Knob Once the chamber is at the desired temperature, typically 620 °F–650 °F, remove the lid completely for the cooking day. (The Tandoor will overheat if the lid is left on after heat-up.) Temperature can be determined using the optional Fluke Hand Held IR Thermometer (see the Tools and Accessories section of the Wood Stone website). Set the Temperature Control Knob to “1.3–1.5”. This should maintain a good cooking temperature for breads and proteins. The Temperature Control Knob will be used to adjust the heat, depending on cooking style. Note that settings may vary slightly depending on gas type (NG or LP). The use of ceramic briquettes, or seasoning the chamber, is unnecessary and will void the warranty. To avoid damage to the top of the Tandoor, do not operate the unit with the lid on except during heat-up. Heat damage caused by operating the Tandoor with the lid on will not be covered by the warranty. Heat-up setting Typical cooking flame setting CLEANING Debris that falls in the Tandoor will accumulate in the bottom of the chamber. Push the debris towards the center and under the circular flame deflector, using the supplied Tandoor Naan Hook, where it will fall into the drip pan under the unit. This pan should be checked daily and emptied as necessary. To remove debris from the chamber walls, first brush the walls with the optional In-Line Floor Brush (see the Tools and Accessories section of the Wood Stone website). Use a moist towel (water only) to swirl around the chamber. Any debris which falls to the bottom of the chamber can be removed as described above. The stainless cabinet and granite top of the unit should be cleaned as necessary, using a mild detergent and a nonabrasive scouring pad. TIP: Watch Wood Stone’s Tandoor-related videos for additional helpful information. Visit the Resource Center/Videos section of the Wood Stone website. NOTE: TO PREVENT DAMAGE TO THE TOP OF THE TANDOOR, DO NOT OPERATE THE TANDOOR WITH THE LID ON EXCEPT DURING HEAT-UP. SOME DISCOLORATION OF THE STONE MAY OCCUR IF THE LID IS OFF WHILE THE UNIT IS RUNNING. THIS NORMAL DISCOLORATION IS ONLY COSMETIC AND DOES NOT HARM THE UNIT. An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 10 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com LIMITED WARRANTY LIMITED WARRANTY Tandoor Installation and Operation Manual CONTACT YOUR LOCAL DISTRIBUTOR FOR WARRANTY SERVICE Wood Stone warrants its equipment to the original purchaser against defects in material or manufacture for a period of one year from the original date of purchase, subject to the following exclusions and limitations. EXCLUSIONS The warranties provided by Wood Stone do not apply in the following instances: 1. In the event that the equipment is improperly installed. Proper installation is the responsibility of the installer; proper installation procedures are prescribed by the Wood Stone Installation and Operation Manual. 2. In the event the equipment is improperly or inadequately maintained. Proper maintenance is the responsibility of the user; proper maintenance procedures are prescribed in the Wood Stone Installation and Operation Manual. Burner problems resulting from debris or ash in the burner well will not be covered by the warranty. Call with questions regarding maintenance frequency. 3. In the event that the failure or malfunction of the appliance or any part thereof is caused by abnormal or improper use or is otherwise not attributable to defect in material or manufacture. 4. In the event that the appliance, by whatever cause, has been materially altered from the condition in which it left the factory. 5. In the event that the rating plate has been removed, altered or obliterated. 6. On parts that would be normally worn or replaced under normal conditions. 7. Normal cracking due to expansion and contraction stress relief in the ceramic firebox. 8. In wood-fired equipment configurations, in the event that pressed log products of any type have been burned in the equipment. 9. In coal-fired oven configurations, in the event any type of coal other than anthracite coal fuel has been used. 10.Damage resulting from the use of chemical cleaning products in the oven, as well as any damage from liquids or chemicals, including water, being poured or sprayed into the oven. If any oral statements have been made regarding this appliance, such statements do not constitute warranties and are not part of the contract of sale. This Limited Warranty constitutes the complete, final and exclusive statement with regard to warranties. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN, ORAL OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS. LIMITATIONS OF LIABILITY In the event of warranty claim or otherwise, the sole obligation of Wood Stone shall be the repair and/or replacement, at the option of Wood Stone, of the appliance or component or part thereof. Such repair or replacement shall be at the expense of Wood Stone with the exception of travel over 100 miles or two hours, overtime, and holiday charges which shall be at the expense of the purchaser. Any repair or replacement under this warranty does not constitute an extension of the original warranty for any period of the appliance or for any component or part thereof. Parts to be replaced under this warranty will be repaired or replaced at the option of Wood Stone with new or functionally operative parts. The liability of Wood Stone on any claim of any kind, including claims based on warranty, expressed or implied, contract, negligence, strict liability or any other theories shall be solely and exclusively the repair or replacement of the product as stated herein, and such liability shall not include, and purchaser specifically renounces any rights to recover, special, incidental, consequential or other damages of any kind whatsoever, including, but not limited to, injuries to persons or damage to property, loss of profits or anticipated profits, or loss of use of the product. TO SECURE WARRANTY SERVICE If you claim a defect covered by this Limited Warranty, contact your local distributor: An ongoing program of product improvement may require us to change specifications without notice. WS-GFT-CE, Revised January 2014 wood stone corporation 1801 w. bakerview rd. bellingham, wa 98226 usa t.+1.360.650.1111 f.+1.360.650.1166 [email protected] or visit woodstone-corp.com 11
© Copyright 2024