ELT Sensor Corp. Ver. 2.1 (Jan. 2014) ELT Sensor Carbon Dioxide (CO₂) Transmitter (3-wired type) Operation Manual CD-300 / CD-300NL CD-300 (with LCD Display) CD-300NL (without LCD Display) Features • Non-Dispersive Infrared(NDIR) technology is used to measure CO₂ levels. • CO2 concentration can be measure as General Analog Voltage /Current value (4~20mA / 2~10V or 0~20mA / 0~10V) CD-300 and CD-300NL are Transmitter type models of CO2 Sensor, which are for 0-20mA , 4-20mA Current output module or 0-10V, 210V Voltage output module(Jumper select) These models give 3 wired input power (2 PWR lines, 1 Common GND line). • Input power 24VAC or 24VDC •.CD-300NL (without Display) is available. • Customer could select multiple functions -. Either of Factory calibration mode or automatic recalibration mode with 1 month period after 3 days. -. 10 minutes manual recalibration function is available as needed. -. CO2 measuring range change between 0~10,000ppm is available. • Simple maintenance (S-200 sensor module are separately connected to main board so that easily managed) • Size : 123 x 69 x 40 (mm) APC Hero 01480 226600 [email protected] ELT Sensor Corp. Ver. 2.1 (Jan. 2014) CD-300 Transmitter Electrical Data Specifications Input Power 24VAC, 24VDC ± 20%, 50/60Hz General Performance (3-Wired) Operating Temperature range Output Signals 0 ~ 50℃ 4 ~ 20mA or 2 ~ 10VDC Operating Humidity range 0 ~ 20mA or 0 ~ 10VDC 0 ~ 95% RH (Non-condensing) , (Jumper selectable -voltage output or current output) Storage Temperature -20℃ ~60℃ CO₂ Measurement Sensing Method NDIR (Non-dispersive Infrared) Measurement Range 0 to 2,000 / 3,000 / 5,000 / 10,000ppm ( with jumper position change) Accuracy ±30ppm ±5% Response Time(90%) 150 seconds Sampling Interval 4 sec. Operation mode selection Two operation mode are available Factory calibration mode and Automatic calibration mode Two manual recalibration methods are available with manual recalibration by change of J2 & J4 or by using TRB-100 Jig (TRB-100 Jig : additionally purchasable) APC Hero 01480 226600 [email protected] Dimensions (unit : mm) ELT Sensor Corp. Ver. 2.1 (Jan. 2014) Jumper Function Descriptions Front Inside View ■ Jumper A (J7, J3) group : Voltage, Current output and range selection. V : Voltage output I : Current output Jumper : C Jumper : A 0~20mA : 0~20mA output @ Current. 0~10V output @ Voltage 4~20mA : 4~20mA output @ Current. 2~10V output @ Voltage. Jumper : B Rear View Example setting : ð Current output and 0 0~ 20mA output ■ Jumper B(J11) group : CO2 Measurement range selection. 10K ppm : 0 ~ 10,000ppm CO2 5K ppm : 0 ~ 5,000ppm CO2 3K ppm : 0 ~ 3,000ppm CO2 2K ppm : 0 ~ 2,000ppm CO2 APC Hero 01480 226600 [email protected] ELT Sensor Corp. Ver. 2.1 (Jan. 2014) 2) 30,000ppm ppm setting and LCD (right end postion+3 postion+3rd position) Real number : 8,710ppm, 11,250ppm (Important notice : when jumper set on high range (20,000~100,000ppm ppm position position), the real ppm from LCD reading must be calculated by LCD display number x 10 ) Example setting : ■ Jumper C (J2, J4) group : Operation mode selection and 10 minute Recalibration 1) 0~2,000ppm setting and LCD function Factory calibration mode: Both jumpers set to ‘OFF’,, ’OFF’ position Automatic Recalibration calibration mode : If users want to operate this CD CD-300 as monthly automatic recalibration mode, please set to ‘ON’ position (ACDL mode) (Auto calibration acts first 3day, and every 30days after power on) Real number : 862ppm (Notice : when jumper set on from 2000ppm ~ 10,000ppm position, the LCD number is the real ppm) 10’ RECAL recalibration : Users can (correction) do 10 minutes manual function when sensor showed much fault ppm. (Pose Jumper-cap to ‘ON ON’ position and wait APC Hero 01480 226600 [email protected] ELT Sensor Corp. Ver. 2.1 (Jan. 2014) over 11 minutes. After the setting of ambient air-flowing flowing status to be 400ppm finished finished, move back the Jumper-cap cap to ‘OFF’ position again.) (For more information, please refer to detailed recalibration manual) Wire ire connector. Output signal calculation examples Example setting : Ex) 3,000ppm range 0~10V mode. Read voltage 3.234V 3,000ppm / 10V * 3.234 = 970 ppm. Ex) 3,000ppm range 2~10V mode. Read voltage 3.234V (3.234V - 2V) * (3000ppm / 8)= 462 ppm. -------------------------------------------------- ð Monthly Automatic recalibrating operation mode ELT Sensor Corp. (Chunui Technopark 101-909) 909) 36, Bucheon Bucheon-ro 198beon-gil, Wonmi-gu, Bucheon-si, Gyeonggi-do, do, 420 420-857, Korea Phone : .82-32-719-8055 Wiring Method VIN+: 24VAC P or 24VDC+, VIN-: 24VAC N or 24VDC-(GND), (GND), A-OUT: Output signal (Voltage or Curr Current). APC Hero 01480 226600 [email protected] Fax : 82-70-8677-8055 http://www.eltsensor.co.kr ELT Sensor All right reserved Subject to change without notice. Printed in KOREA
© Copyright 2024