ZS-112148 A (Feeder Terminal Unit) OPERATION MANUAL 0 Elemote FRTU 1 Elemote FRTU ﻣﻌﺮﻓﻲ ﺷﺮﻛﺖ ﺯﺭﻳﻦ ﺳﺎﻣﺎﻧﻪ ﺷﺮﻕ ﺷﺮﻛﺖ ﺯﺭﻳﻦ ﺳﺎﻣﺎﻧﻪ ﺷﺮﻕ ﺑﻪ ﻋﻨﻮﺍﻥ ﺍﻭﻟﻴﻦ ﻃﺮﺍﺡ ﻭ ﺳﺎﺯﻧﺪﻩ ﺗﺠﻬﻴﺰﺍﺕ ﺍﻧﺘﻘﺎﻝ ﺍﻃﻼﻋـﺎﺕ ﻭ ﻛﻨﺘـﺮﻝ ﺍﺯ ﺭﺍﻩ ﺩﻭﺭ ﺩﺭ ﺻـﻨﻌﺖ ﻓﻌﺎﻟﻴﺖ ﺭﺳﻤﻲ ﺧﻮﺩ ﺭﺍ ﺍﺯ ﺳﺎﻝ 1374ﺑﺎ ﻧﺎﻡ ﺷﺮﻛﺖ ﺗﻌﺎﻭﻧﻲ ﻧﻴﻚ ﺗﻜﻨﻴﻚ ﺁﻏﺎﺯ ﻧﻤﻮﺩﻩ ﻭ ﺩﺭ ﺳﺎﻝ 1386ﺑﻪ ﺩﻟﻴـﻞ ﺳﻴﺎﺳـﺖ- ﻫﺎﻱ ﻛﺎﺭﻱ ﺧﻮﺩ ،ﺑﻪ ﻧﺎﻡ ﺷﺮﻛﺖ ﺯﺭﻳﻦ ﺳﺎﻣﺎﻧﻪ ﺷﺮﻕ ﻓﻌﺎﻟﻴﺖ ﺧﻮﺩ ﺭﺍ ﺍﺩﺍﻣﻪ ﺩﺍﺩﻩ ﺍﺳﺖ .ﺩﺭ ﺣﺎﻝ ﺣﺎﺿﺮ ﺍﻳﻦ ﺷـﺮﻛﺖ ﻋـﻼﻭﻩ ﺑـﺮ ﺍﺟﺮﺍﻱ ﺑﻴﺸﺘﺮﻳﻦ ﺗﻌﺪﺍﺩ ﻧﻮﺩﻫﺎ ﺩﺭ ﺻﻨﻌﺖ ﺁﺏ ﺩﺭ ﺳﺮﺍﺳﺮ ﻛﺸﻮﺭ ،ﻓﻌﺎﻟﻴﺖﻫﺎﻱ ﺧﻮﺩ ﺭﺍ ﺩﺭ ﺻﻨﻌﺖ ﺑﺮﻕ ﻭ ﺍﺗﻮﻣﺎﺳﻴﻮﻥ ﺷﺒﻜﻪﻫﺎﻱ ﺗﻮﺯﻳﻊ ﻧﻴﺰ ﮔﺴﺘﺮﺵ ﺩﺍﺩﻩ ﺍﺳﺖ. ﺷﺮﻛﺖ ﺯﺭﻳﻦ ﺳﺎﻣﺎﻧﻪ ﺷﺮﻕ ﺩﺭ ﺭﺍﺳﺘﺎﻱ ﺑﻮﻣﻲ ﺳﺎﺯﻱ ،ﻛﻠﻴﻪ ﺗﺠﻬﻴﺰﺍﺕ ﺳﺨﺖ ﺍﻓﺰﺍﺭﻱ ﻭ ﻧﺮﻡ ﺍﻓﺰﺍﺭﻫﺎﻱ ﻣﻮﺭﺩ ﻧﻴـﺎﺯﺧﻮﺩ ﺭﺍ ﺩﺭ ﺭﺍﺳﺘﺎﻱ ﺍﺟﺮﺍﻱ ﭘﺮﻭژﻩ ﻫﺎﻱ ﺍﺗﻮﻣﺎﺳﻴﻮﻥ ﺻﻨﻌﺘﻲ ﻭ ﺍﺗﻮﻣﺎﺳﻴﻮﻥ ﺗﻮﺯﻳﻊ ﺷﺎﻣﻞ ﻃﺮﺍﺣﻲ ،ﺳـﺎﺧﺖ ،ﻣﻮﻧﺘـﺎژ ،ﺑﺮﻧﺎﻣـﻪ ﻧﻮﻳﺴـﻲ ﺑﻄـﻮﺭ ﻛﺎﻣﻞ ﺩﺍﺧﻞ ﺷﺮﻛﺖ ﻭ ﺗﻮﺳﻂ ﻣﺘﺨﺼﺼﻴﻦ ﻣﺠﺮﺏ ﺧﻮﺩ ﺍﻧﺠﺎﻡ ﻣﻲ ﺩﻫﺪ. Elemote FRTU 2 ﻗﺎﺑﻠﻴﺖ ﻫﺎ : ZS-112148Aﺑﺮﺍﻱ ﺍﺳﺘﻔﺎﺩﻩ ﺩﺭ ﺍﺗﻮﻣﺎﺳﻴﻮﻥ ﺷﺒﻜﻪ ﻫﺎﻱ ﺗﻮﺯﻳﻊ ﻭ ﻫﻤﻴﻨﻄﻮﺭ ﺑﺮﺍﻱ ﻛﺎﻫﺶ ﺯﻣﺎﻥ ﺧﺎﻣﻮﺷﻲ ﺩﺭ ﺷﺒﻜﻪ ﻫﺎﻱ ﺩﺍﺭﺍﻱ ﺧﻄﺎ ،ﻃﺮﺍﺣﻲ ﻭ ﺳﺎﺧﺘﻪ ﺷﺪﻩ ﺍﺳﺖ .ﺍﻳﻦ ﻛﻨﺘﺮﻟﺮ ﺩﺍﺭﺍﻱ ﺗﻮﺍﺑﻌﻲ ﻗﺪﺭﺗﻤﻨﺪ ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ ﻣﻮﺭﺩ ﻧﻴﺎﺯ ﺍﺗﻮﻣﺎﺳﻴﻮﻥ ﺷﺒﻜﻪ ﻫﺎﻱ ﺗﻮﺯﻳﻊ ﺍﺳﺖ .ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﺜﺎﻝ ﻣﻲ ﺗﻮﺍﻥ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺗﻤﺎﻣﻲ ﭘﺎﺭﺍﻣﺘﺮﻫﺎﻱ ﺍﻟﻜﺘﺮﻳﻜﻲ ﻭ ﺍﺭﺗﺒﺎﻃﻲ ﻭ ﻫﻤﭽﻨﻴﻦ ﻛﻠﻴﻪ ﻣﻘﺎﺩﻳﺮ ﭘﺎﺭﺍﻣﺘﺮﻫﺎﻱ ﻓﻮﻕ ﺭﺍ ﺑﻪ ﻣﻨﻈﻮﺭ ﻛﻨﺘﺮﻝ ﺳﻮﺋﻴﭻ ﻫﺎ ﺑﻪ ﺻﻮﺭﺕ ﻛﻨﺘﺮﻝ ﻣﺤﻠﻲ ﻭ ﻛﻨﺘﺮﻝ ﺍﺯ ﺭﺍﻩ ﺩﻭﺭ ﺍﻧﺠﺎﻡ ﺩﺍﺩ. ﺍﺯ ﺩﻳﮕﺮ ﻗﺎﺑﻠﻴﺖ ﻫﺎﻱ ﺍﻳﻦ ﺗﺠﻬﻴﺰ ﺍﺗﺼﺎﻝ ﺑﻪ ﺍﻧﻮﺍﻉ ﺑﺴﺘﺮﻫﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ ﻭ ﻣﺨﺎﺑﺮﺍﺗﻲ ﻣﻲ ﺑﺎﺷﺪ ZS-112148A .ﺩﺍﺭﺍﻱ ﺍﻣﻜﺎﻥ ﺛﺒﺖ ﻭﻗﺎﻳﻊ ﻭ ﺭﺧﺪﺍﺩﻫﺎ ﻧﻴﺰ ﻣﻲ ﺑﺎﺷﺪ ﻛﻪ ﺑﺮﺍﻱ ﺗﺤﻠﻴﻞ ﺷﺒﻜﻪ ﻭ ﺑﺎﺭ ﻣﻮﺭﺩ ﺍﺳﺘﻔﺎﺩﻩ ﻗﺮﺍﺭ ﻣﻲ ﮔﻴﺮﺩ .ﺗﻤﺎﻣﻲ ﺍﻃﻼﻋﺎﺕ ﻣﺮﺑﻮﻁ ﺑﻪ ﺧﻄﺎﻫﺎ ﻭ ﺭﺧﺪﺍﺩﻫﺎ ﺑﻪ ﺻﻮﺭﺕ ﻓﺮﻣﺖ Textﻣﻲ ﺗﻮﺍﻧﻨﺪ ﺑﺮ ﺭﻭﻱ ﺻﻔﺤﻪ ﻧﻤﺎﻳﺶ ﻧﺸﺎﻥ ﺩﺍﺩﻩ ﺷﻮﻧﺪ ﻭ ﻳﺎ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻧﺮﻡ ﺍﻓﺰﺍﺭﻫﺎﻱ ﺟﺎﻧﺒﻲ ﺑﻪ ﺻﻮﺭﺕ ﮔﺮﺍﻓﻴﻜﻲ ﺑﻪ ﻧﻤﺎﻳﺶ ﺩﺭ ﺁﻳﻨﺪ. ﻛﺎﺭﺑﺮ ﻣﻲ ﺗﻮﺍﻧﺪ ﻣﺘﻨﺎﺳﺐ ﺑﺎ ﺷﺮﺍﻳﻂ ﻣﺨﺘﻠﻒ ﺑﻬﺮﻩ ﺑﺮﺩﺍﺭﻱ ،ﺗﻨﻈﻴﻤﺎﺕ ZS-112148Aﺭﺍ ﺑﻪ ﺻﻮﺭﺕ ﭘﻴﺶ ﻓﺮﺽ ﺗﻨﻈﻴﻢ ﻧﻤﺎﻳﺪ .ﻫﻤﭽﻨﻴﻦ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ ﻛﻠﻴﺪﻫﺎﻱ Remote/ Localﺍﻳﻦ ﺍﻣﻜﺎﻥ ﺭﺍ ﺩﺍﺭﺩ ﻛﻪ ﺳﻴﺴﺘﻢ ﺭﺍ ﺍﺯ ﺣﺎﻟﺖ ﺭﺍﻩ ﺩﻭﺭ ﺧﺎﺭﺝ ﻛﺮﺩﻩ ﻭ ﺑﻪ ﺣﺎﻟﺖ ﻣﺤﻠﻲ ﻭ ﻳﺎ ﺑﺎﻟﻌﻜﺲ ﺑﺒﺮﺩ. Elemote FRTU 3 ) ( Phase & Ground Fault Detection ZS-112148Aﺍﺳﺎﺳﺎ ﺑﺮﺍﻱ ﺍﻳﻦ ﻃﺮﺍﺣﻲ ﺷﺪﻩ ﺍﺳﺖ ﻛﻪ ﺧﻄﺎﻱ ﻣﺮﺑﻮﻁ ﺑﻪ ﺳﻪ ﻓﺎﺯ ﻭ ﻫﻤﭽﻨﻴﻦ ﺍﺗﺼﺎﻝ ﺯﻣﻴﻦ ﺭﺍ ﺁﺷﻜﺎﺭ ﻧﻤﺎﻳﺪ .ﺟﺮﻳﺎﻥ ﻫﺎ ﻭ ﺍﺗﺼﺎﻝ ﺯﻣﻴﻦ ﺩﺍﺭﺍﻱ ﻳﻚ ﻣﻘﺪﺍﺭ ﭘﻴﺶ ﺗﻨﻈﻴﻢ ﻣﻲ ﺑﺎﺷﻨﺪ ﻭ ﭼﻨﺎﻧﭽﻪ ﻫﺮﻳﻚ ﺍﺯ ﺟﺮﻳﺎﻥ ﻫﺎ ﺍﺯ ﻣﻘﺪﺍﺭ ﺗﻨﻈﻴﻤﻲ ﺁﻥ ﺑﻴﺸﺘﺮ ﺷﻮﺩ ،ﻧﻤﺎﻳﺸﮕﺮ ﺧﻄﺎﻱ ﻣﺮﺑﻮﻃﻪ ﺭﻭﺷﻦ ﻣﻲ ﮔﺮﺩﺩ. SEF (Selective Earth Fault) Protection ﺩﺭ ﻳﻚ ﺷﺒﻜﻪ ﺑﺮﻕ ﺑﺪﻭﻥ ﺍﺗﺼﺎﻝ ﺑﻪ ﺯﻣﻴﻦ ﺑﻪ ﺩﻟﻴﻞ ﺟﺮﻳﺎﻥ ﻛﻢ ﺯﻣﻴﻦ ﺑﻪ ﺳﺨﺘﻲ ﻣﻲ ﺗﻮﺍﻥ ﺧﻄﺎﻫﺎﻱ ﺟﺮﻳﺎﻧﻲ ﺭﺍ ﻣﺸﺨﺺ ﻛﺮﺩ .ﺑﻨﺎﺑﺮﺍﻳﻦ ZS-112148Aﺑﻪ ﮔﻮﻧﻪ ﺍﻱ ﻃﺮﺍﺣﻲ ﺷﺪﻩ ﺍﺳﺖ ﻛﻪ ﺑﺘﻮﺍﻧﺪ ﺑﺎ ﺍﺳﺘﻔﺎﺩﻩ ﺍﺯ CTﻫﺎﻱ ﺧﺎﺭﺟﻲ ﺑﻪ ﺁﺷﻜﺎﺭﺳﺎﺯﻱ ﺧﻄﺎ ﺩﺭ ﻓﺎﺯﻫﺎ ﺍﻗﺪﺍﻡ ﻧﻤﺎﻳﺪ .ﺍﻳﻦ ﺗﺎﺑﻊ ﺑﻪ ﻃﻮﺭ ﺧﻼﺻﻪ SEFﻧﺎﻣﻴﺪﻩ ﻣﻲ ﺷﻮﺩ .ﺩﺭ ﻣﻮﺍﺭﺩﻱ ﻛﻪ ﺩﺭ ﻳﻚ ﺷﺒﻜﻪ ﺯﻣﻴﻦ ﺷﺪﻩ ،ﺧﻄﺎﻱ ﺍﺗﺼﺎﻝ ﺯﻣﻴﻦ ﺭﻭﻱ ﺩﻫﺪ ،ﻣﻲ ﺗﻮﺍﻧﺪ ﺧﻄﺎ ﺭﺍ ﺗﺸﺨﻴﺺ ﺩﻫﺪ) .ﺿﻤﻨﺎ ﻗﺎﺑﻠﻴﺖ ﺗﺸﺨﻴﺺ ﺟﺮﻳﺎﻥ ﻟﺤﻈﻪ ﺍﻱ ﺑﺎﻻﻱ 100ﻣﻴﻠﻲ ﺛﺎﻧﻴﻪ ﺭﺍ ﺩﺍﺭﺩ(. Cold Load pick up ﺩﺭ ﻳﻚ ﺷﺒﻜﻪ ﻫﺮﮔﺎﻩ ﺧﻂ ﻣﺠﺪﺩﺍ ﻓﻌﺎﻝ ﺷﻮﺩ ﻣﻤﻜﻦ ﺍﺳﺖ ﭘﺪﻳﺪﻩ ﺍﻱ ﺭﻭﻱ ﺩﻫﺪ ﻛﻪ ﺟﺮﻳﺎﻥ ﺑﻪ ﺻﻮﺭﺕ ﻟﺤﻈﻪ ﺍﻱ ﺍﺯ ﻣﻘﺪﺍﺭ ﺑﺎﺭﮔﻴﺮﻱ ﺷﺪﻩ ) (Pick upﺑﻴﺸﺘﺮ ﺷﺪﻩ ﻭ ﺳﭙﺲ ﺑﻪ ﻣﻘﺪﺍﺭ ﻋﺎﺩﻱ ﺧﻮﺩ ﻛﺎﻫﺶ ﻣﻲ ﻳﺎﺑﺪ ﻛﻪ ﺍﻳﻦ ﺟﺮﻳﺎﻥ ،ﺟﺮﻳﺎﻥ ﺑﺎﺭ ﺳﺮﺩ ﻧﺎﻣﻴﺪﻩ ﻣﻲ ﺷﻮﺩ .ﻣﻘﺪﺍﺭ ﺑﺎﺭﮔﻴﺮﻱ ﺑﺎﺭ ﺳﺮﺩ ) (Cold Load Pick upﺑﺮﺍﻱ ﺗﻔﻜﻴﻚ ﺍﻳﻦ ﭘﺪﻳﺪﻩ ﺍﺯ ﺟﺮﻳﺎﻥ ﻫﺎﻱ ﺧﻄﺎﺳﺖ .ﺑﻪ ﻋﻨﻮﺍﻥ ﻣﺜﺎﻝ ﺑﺪﻭﻥ ﺗﻐﻴﻴﺮ ﭘﺎﺭﺍﻣﺘﺮﻫﺎﻱ ﺗﻨﻈﻴﻤﻲ ،ﺳﻄﺢ Pickupﺩﺭ ﺯﻣﺎﻥ ﻭﻗﻮﻉ ﺟﺮﻳﺎﻥ ﺑﺎﺭ ﺳﺮﺩ ﺑﻪ ﻃﻮﺭ ﺍﺗﻮﻣﺎﺕ ﺗﻐﻴﻴﺮ ﻛﺮﺩﻩ ﻭ ﺑﻌﺪ ﺍﺯ ﮔﺬﺷﺖ ﺯﻣﺎﻥ ،ﺟﺮﻳﺎﻥ ﺳﺮﺩ ﻛﻪ ﻗﺎﺑﻞ ﺗﻨﻈﻴﻢ ﺍﺳﺖ ﺑﻪ ﺳﻄﺢ ﺑﺎﺭ ﮔﻴﺮﻱ ﺍﻭﻟﻴﻪ ﺑﺮ ﻣﻲ ﮔﺮﺩﺩ. ﺍﻳﻦ ﺗﻨﻈﻴﻤﺎﺕ ﺑﺮﺍﻱ ﻓﺎﺯﻫﺎ ﻭ ﺟﺮﻳﺎﻥ ﺯﻣﻴﻦ ﻣﻲ ﺑﺎﺷﺪ .ﻣﻘﺪﺍﺭ ﺻﻔﺮ ﺑﺮﺍﻱ Cold Load Multierﺑﺪﻳﻦ ﻣﻌﻨﺎﺳﺖ ﻛﻪ Cold Load Pickupﻏﻴﺮﻓﻌﺎﻝ ﺍﺳﺖ . Elemote FRTU 4 ﻭﻳﮋﮔﻲ ﻫﺎ : ﺗﺸﺨﻴﺺ ﺧﻄﺎﻱ ﻓﺎﺯ ،ﺧﻄﺎﻱ ﺯﻣﻴﻦ ﺗﺸﺨﻴﺺ ﺧﻄﺎ ﺗﺸﺨﻴﺺ ﺧﻄﺎﻱ ﺑﺎﺭﮔﻴﺮﻱ ﺍﻭﻟﻴﻪ ﻭ ﺟﺮﻳﺎﻥ ﻫﺎﻱ ﻫﺠﻮﻣﻲ ﺳﻮﺋﭽﻴﻨﮓ ﺗﺸﺨﻴﺺ ﻭﻟﺘﺎژ ﺳﻤﺖ ﺑﺎﺭ ﻭ ﻣﻨﺒﻊ ﺗﺸﺨﻴﺺ ﺳﻨﻜﺮﻭﻥ ﺑﻮﺩﻥ ﻭﻟﺘﺎژﻫﺎﻱ ﺑﺎﺭ ﻭ ﻣﻨﺒﻊ ﺩﺭ ﺣﺎﻟﺖ ﺭﻳﻨﮓ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﻭﻟﺘﺎژ ﻣﻨﺒﻊ ﻭ ﺑﺎﺭ ﻭ ﺟﺮﻳﺎﻥ ﻫﺮ ﺳﻪ ﻓﺎﺯ ﻓﺮﻛﺎﻧﺲ ،ﺿﺮﻳﺐ ﺗﻮﺍﻥ ﻭ ﺯﺍﻭﻳﻪ ﺑﻴﻦ Vaﻭ Vs ﻛﻨﺘﺮﻝ ﻭﺿﻌﻴﺖ )ﻣﺤﻠﻲ ،ﺭﺍﻩ ﺩﻭﺭ( ﻛﻨﺘﺮﻝ ﻛﻨﺘﺮﻝ ) LBSﺑﺎﺯ ،ﺑﺴﺘﻪ( ﻧﻤﺎﻳﺶ ﺧﻄﺎ ) ﺭﻳﺴﺖ ﺩﺳﺘﻲ ﻧﻤﺎﻳﺸﮕﺮ ﺧﻄﺎ ( ،ﺗﺴﺖ ﺑﺎﻃﺮﻱ ﻭﺿﻌﻴﺖ ﻛﻠﻴﺪ )ﺑﺎﺯ ،ﺑﺴﺘﻪ( ﻧﻤﺎﻳﺶ ﻭﺿﻌﻴﺖ ﻣﻮﻗﻌﻴﺖ ﻛﻨﺘﺮﻝ )ﻣﺤﻠﻲ ،ﺭﺍﻩ ﺩﻭﺭ( ﻧﻤﺎﻳﺶ ﺧﻄﺎ )(Ia/Ib/Ic/In ﻗﻄﻊ ﺑﻮﺩﻥ ﺑﺮﻕ ﺗﻐﺬﻳﻪ ، ACﺑﺎﺯ ﺑﻮﺩﻥ ﺩﺭﺏ ﺗﺎﺑﻠﻮ Low Battery ﺷﻤﺎﺭﻧﺪﻩ ﺩﻓﻌﺎﺕ ﺭﺍﻩ ﺍﻧﺪﺍﺯﻱ ﻣﺠﺪﺩ RTU ﺷﻤﺎﺭﻧﺪﻩ ﺷﻤﺎﺭﻧﺪﻩ ﺩﻓﻌﺎﺕ ﺑﺎﺯ ﻭ ﺑﺴﺘﻪ ﺷﺪﻥ ﻛﻠﻴﺪ ﭘﺮﻭﺗﻜﻞ ﺍﺭﺗﺒﺎﻃﻲ ﺍﺳﻜﺎﺩﺍ Modbus ،DNP3: Elemote FRTU ﺷﻤﺎﺭﻧﺪﻩ ﺗﻌﺪﺍﺩ ﺧﻄﺎ ﺗﻨﻈﻴﻤﺎﺕ Modbus : 5 : Display .1ﻧﻤﺎﻳﺸﮕﺮ .2ﻧﻤﺎﻳﺶ ﻭﺿﻌﻴﺖ ﺩﺭﺏ ﺍﻳﺴﺘﮕﺎﻩ .3ﻧﻤﺎﻳﺶ ﻭﺿﻌﻴﺖ ﺩﺭﺏ ﺗﺎﺑﻠﻮ .4ﺩﺭﻳﺎﻓﺖ ﺍﻃﻼﻋﺎﺕ ﺍﺯ ﻣﺮﻛﺰ ﺍﺳﻜﺎﺩﺍ ،ﺍﺭﺳﺎﻝ ﺍﻃﻼﻋﺎﺕ ﺑﻪ ﻣﺮﻛﺰ ﺍﺳﻜﺎﺩﺍ .5ﻣﻨﺒﻊ ﺗﻐﺬﻳﻪ .6ﭘﺎﻳﻴﻦ ﺑﻮﺩﻥ ﺩﻣﺎﻱ ﺭﻭﻏﻦ ﺗﺮﺍﻧﺲ .7ﻧﺸﺎﻥ ﺩﻫﻨﺪﻩ ﻭﺿﻌﻴﺖ ﺍﺭﺗﺒﺎﻁ ﺑﺎ RTU .8ﭘﺎﻳﻴﻦ ﺑﻮﺩﻥ ﺳﻄﺢ ﺭﻭﻏﻦ ﺗﺮﺍﻧﺲ .9ﻧﻤﺎﻳﺶ ﭘﺎﻳﻴﻦ ﺑﻮﺩﻥ ﻓﺸﺎﺭ ﮔﺎﺯ .10ﭘﺎﻳﻴﻦ ﺑﻮﺩﻥ ﻭﻟﺘﺎژ ﺑﺎﻃﺮﻱ .11ﻧﻤﺎﻳﺶ ﺧﻄﺎﻱ Different Phase .12ﻧﻤﺎﻳﺶ ﺧﻄﺎﻱ Volt Indicator .13ﻧﻤﺎﻳﺶ ﺧﻄﺎﻱ Fault Indicator Elemote FRTU 6 .14ﺷﺼﺘﻲ ﻛﻨﺘﺮﻝ ﻭﺿﻌﻴﺖ ﺗﺎﺑﻠﻮ ﺑﻪ ﺣﺎﻟﺖ ﻣﺤﻠﻲ ﻳﺎ ﺭﺍﻩ ﺩﻭﺭ .15ﻗﻄﻊ ﺑﻮﺩﻥ ﺗﻐﺬﻳﻪ AC .16ﺷﺼﺘﻲ ﻣﻴﺎﻧﺒﺮ ﺟﻬﺖ ﻧﻤﺎﻳﺶ ﻭﻟﺘﺎژ ﻭ ﺟﺮﻳﺎﻥ : Enter .17ﺷﺼﺘﻲ ﺗﺎﻳﻴﺪ : Left/Right /UP/Down .18ﺷﺼﺘﻲ ﻫﺎﻱ ﺑﺎﻻ ،ﭘﺎﻳﻴﻦ ،ﭼﭗ ﻭ ﺭﺍﺳﺖ .19ﺷﺼﺘﻲ ﺭﻳﺴﺖ ﻛﺮﺩﻥ ﺧﻄﺎﻫﺎ ﺑﻪ ﺻﻮﺭﺕ ﺩﺳﺘﻲ : Back .20ﺷﺼﺘﻲ ﺑﺎﺯﮔﺸﺖ .21ﺷﺼﺘﻲ ﺭﻳﺴﺖ ﻛﺮﺩﻥ ﺧﻄﺎﻫﺎ ﺑﻪ ﺻﻮﺭﺕ ﺩﺳﺘﻲ .22ﻧﻤﺎﻳﺶ ﻭﺿﻌﻴﺖ Earth .23ﺷﺼﺘﻲ ﻓﻌﺎﻝ ﻧﻤﻮﺩﻥ ﻓﺮﻣﺎﻥ ﺑﺎﺯ ﻛﻠﻴﺪ ﺑﻪ ﺻﻮﺭﺕ ﺩﺳﺘﻲ .24ﺷﺼﺘﻲ ﻓﻌﺎﻝ ﻧﻤﻮﺩﻥ ﻓﺮﻣﺎﻥ ﺑﺴﺘﻪ ﻛﻠﻴﺪ ﺑﻪ ﺻﻮﺭﺕ ﺩﺳﺘﻲ .25ﺷﺼﺘﻲ ﻏﻴﺮﻓﻌﺎﻝ ﻧﻤﻮﺩﻥ ﺗﻐﻴﻴﺮ ﻭﺿﻌﻴﺖ ﻛﻠﻴﺪ )ﺍﺯ ﺭﺍﻩ ﺩﻭﺭ ﻭ ﻣﺤﻠﻲ( .26ﻧﻤﺎﻳﺶ ﻭﺿﻌﻴﺖ ﺧﺮﻭﺟﻲ ﻫﺎ )(Open , Close , Earth Elemote FRTU 7 :LCD ﮔﺮﺍﻓﻴﻜﻲ 64*128ﭘﻴﻜﺴﻞ ،ﺩﺍﺭﺍﻱ Backlight ﺗﻨﻈﻴﻢ ﻭ ﭘﻴﻜﺮﻩ ﺑﻨﺪﻱ ﺳﻴﺴﺘﻢ ،ﻧﻤﺎﻳﺶ ﻣﻘﺎﺩﻳﺮ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺷﺪﻩ : OK/UP/Down/Right/Left/Esc ﻛﻠﻴﺪﻫﺎﻱ ﻓﻮﻕ ﺑﺮﺍﻱ ﻛﺎﺭ ﺑﺎ ﻧﻤﺎﻳﺸﮕﺮ ﻭ ﭘﻴﻜﺮﻩ ﺑﻨﺪﻱ ﺳﻴﺴﺘﻢ ﺍﺳﺘﻔﺎﺩﻩ ﻣﻲ ﺷﻮﺩ. : Reset ﺑﺮﺍﻱ ﺭﻳﺴﺖ ﻛﺮﺩﻥ ﻧﺸﺎﻥ ﺩﻫﻨﺪﻩ ﻫﺎﻱ ﺧﻄﺎ ﻭ ﺧﻄﺎﻱ ﺳﻴﺴﺘﻢ ﺑﻪ ﻛﺎﺭ ﻣﻲ ﺭﻭﺩ. : Battery test ﺍﻳﻦ ﻛﻠﻴﺪ ﺑﺮﺍﻱ ﺗﺴﺖ ﺑﺎﻃﺮﻱ ﻭ ﻣﺪﺍﺭ ﺷﺎﺭژ ﺁﻥ ﺑﻪ ﻛﺎﺭ ﻣﻲ ﺭﻭﺩ .ﺩﺭ ﺻﻮﺭﺕ ﻋﺎﺩﻱ ﺑﻮﺩﻥ ﻭﺿﻌﻴﺖ ﺑﺎﻃﺮﻱ LEDﻣﺮﺑﻮﻁ ﺑﻪ ﺁﻥ ﺧﺎﻣﻮﺵ ﻭ ﺩﺭ ﻏﻴﺮ ﺍﻳﻨﺼﻮﺭﺕ LEDﺁﻥ ﺭﻭﺷﻦ ﻣﻲ ﺷﻮﺩ .ﺩﺭ ﺯﻣﺎﻥ ﺍﺗﺼﺎﻝ ﺑﺮﻕ ACﻭﺭﻭﺩﻱ ،ﺑﺎﻃﺮﻱ ﺑﻪ ﻃﻮﺭ ﺍﺗﻮﻣﺎﺕ ﺗﺴﺖ ﻧﻤﻲ ﮔﺮﺩﺩ ﻭ ﺑﺮﺍﻱ ﺗﺴﺖ ﻣﻲ ﺑﺎﻳﺴﺖ ﺍﺯ ﺷﺼﺘﻲ BAT_Testﺍﺳﺘﻔﺎﺩﻩ ﻧﻤﻮﺩ. : Remote control ﻭﺿﻌﻴﺖ ﻓﺮﻣﺎﻥ ﭘﺬﻳﺮﻱ ﻛﻨﺘﺮﻟﺮ ﺭﺍ ﺗﻌﻴﻴﻦ ﻣﻲ ﻛﻨﺪ .ﺍﻳﻦ ﻛﻠﻴﺪ ﻓﻘﻂ ﺑﻪ ﺻﻮﺭﺕ ﻣﺤﻠﻲ ﻓﻌﺎﻝ ﻣﻲ ﺷﻮﺩ ﺍﻣﺎ ﻣﺎﻧﻴﺘﻮﺭﻳﻨﮓ ﺁﻥ ﺍﺯ ﺭﺍﻩ ﺩﻭﺭ ﻧﻴﺰ ﺍﻣﻜﺎﻥ ﭘﺬﻳﺮ ﺍﺳﺖ .ﺍﻳﻦ ﺍﻣﺮ ﺑﺮﺍﻱ ﺣﻔﻆ ﺍﻣﻨﻴﺖ ﺑﻬﺮﻩ ﺑﺮﺩﺍﺭ ﻭ ﻳﺎ ﻛﺎﺭﺑﺮ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪﻩ ﺍﺳﺖ . ﺟﻬﺖ ﻛﺎﺭ ﺑﺎ ﻫﺮﻳﻚ ﺍﺯ ﺷﺼﺘﻲ ﻫﺎﻱ BAT_Test ، Close ، Open ، Resetﻭﺿﻌﻴﺖ ﻛﻨﺘﺮﻝ ﺑﺎﻳﺪ ﺩﺭ ﺣﺎﻟﺖ ﻣﺤﻠﻲ ﺑﺎﺷﺪ . :open/close ﺍﻳﻦ ﻛﻠﻴﺪ ﻫﺎ ﺑﻪ ﻣﻨﻈﻮﺭ ﻓﺮﻣﺎﻥ ﻣﺤﻠﻲ open/closeﻛﻠﻴﺪ ﺑﻪ ﻛﺎﺭ ﻣﻲ ﺭﻭﺩ .ﻗﺒﻞ ﺍﺯ ﺑﺎﺯ ﻭ ﻳﺎ ﺑﺴﺘﻦ ﻛﻠﻴﺪ ﺍﺑﺘﺪﺍ ﺑﻪ ﻭﺿﻌﻴﺖ ﻣﺤﻠﻲ ﺁﻥ ﺑﺎﻳﺪ ﺗﻮﺟﻪ ﻛﺮﺩ ﺳﭙﺲ ﻓﺮﻣﺎﻥ ﺑﺎﺯ ﻭ ﺑﺴﺘﻪ ﺷﺪﻥ ﻛﻠﻴﺪ ﺭﺍ ﻓﺸﺎﺭ ﺩﻫﻴﺪ .ﺑﺮﺍﻱ ﺗﻐﻴﻴﺮ ﻭﺿﻌﻴﺖ ﻣﺮﺍﺣﻞ ﻓﻮﻕ ﺗﻜﺮﺍﺭ ﻣﻲ ﺷﻮﺩ. Elemote FRTU 8 ﻣﺸﺨﺼﺎﺕ ﻓﻨﻲ ﺁﺷﻜﺎﺭﺳﺎﺯﻱ ﺧﻄﺎ ﺗﺸﺨﻴﺺ ﻗﻄﻊ ﻓﺎﺯ ﺗﺴﺖ ﻫﻤﺰﻣﺎﻧﻲ ﺳﻄﺢ ﺗﺸﺨﻴﺺ ﻭﺟﻮﺩ ﻭﻟﺘﺎژ ( 50 – 90) % :ﻭﻟﺘﺎژ ﻧﺎﻣﻲ ﺳﻄﺢ ﺗﺸﺨﻴﺺ ﻗﻄﻊ ﻭﻟﺘﺎژ ( 35 – 70) % :ﻭﻟﺘﺎژ ﻧﺎﻣﻲ ﺯﻣﺎﻥ ﺗﺎﺧﻴﺮ 0/1 – 30 :ﺛﺎﻧﻴﻪ ﺍﺧﺘﻼﻑ ﻓﺎﺯ ﺧﻄﺎﻱ ﺳﻨﻜﺮﻭﻥ 5 – 60 :ﺩﺭﺟﻪ ﺯﻣﺎﻥ ﺗﺎﺧﻴﺮ 1 – 30 :ﺛﺎﻧﻴﻪ ﭘﻴﻜﺮﻩ ﺑﻨﺪﻱ ﺳﻴﺴﺘﻢ ﻣﻘﺎﺩﻳﺮ ﻧﺎﻣﻲ ﻭﺭﻭﺩﻱ /ﺧﺮﻭﺟﻲ ﻓﺮﻛﺎﻧﺲ 50 : ﻭﻟﺘﺎژ ﻧﺎﻣﻲ 3/8 – 21 :ﻛﻴﻠﻮ ﻭﻟﺖ ﻧﺴﺒﺖ ﺗﺮﺍﻧﺲ ﺟﺮﻳﺎﻥ 100/1 – 2000/1 : ﺯﻣﺎﻥ ﺩﻳﺒﺎﻧﺲ ﻭﺭﻭﺩﻱ ﺩﻳﺠﻴﺘﺎﻝ 10 – 500 :ﺛﺎﻧﻴﻪ ﻋﺮﺽ ﭘﺎﻟﺲ ﺧﺮﻭﺟﻲ ﺩﻳﺠﻴﺘﺎﻝ 10 – 2000 :ﻣﻴﻠﻲ ﺛﺎﻧﻴﻪ ﻧﻤﺎﻳﺶ ﻭﺿﻌﻴﺖ ﻫﺎ ﻭﺿﻌﻴﺖ ﻫﺎ ﻛﻨﺘﺮﻝ ﺑﺎﺯ /ﺑﺴﺘﻪ ﻣﺤﻠﻲ /ﺭﺍﻩ ﺩﻭﺭ ﻗﻔﻞ ﺩﺳﺘﻲ ﻓﺸﺎﺭ ﭘﺎﻳﻴﻦ ﮔﺎﺯ ﺑﺎﺯ ﺑﻮﺩﻥ ﺩﺭﺏ ﺧﻄﺎﻱ ﻓﺎﺯ ﺗﺨﻠﻴﻪ ﺑﺎﻃﺮﻱ ﻗﻄﻊ ﺗﻐﺬﻳﻪ 220ﻭﻟﺖ ﺧﻄﺎﻱ ﺳﻴﺴﺘﻢ RTU ﻭﺿﻌﻴﺖ ﺍﺭﺗﺒﺎﻁ ﻣﺤﻠﻲ /ﺭﺍﻩ ﺩﻭﺭ ﺗﻌﻴﻴﻦ ﻧﻮﻉ ﻛﻨﺘﺮﻝ ﺭﻳﺴﺖ ﺭﻳﺴﺖ ﻛﻠﻴﻪ ﺧﻄﺎﻫﺎ ﺑﺎﺯ ﻭ ﺑﺴﺘﻪ ﺗﺴﺖ ﺑﺎﻃﺮﻱ Elemote FRTU ﻓﺮﻣﺎﻥ ﺑﺎﺯ ﻳﺎ ﺑﺴﺘﻦ ﻛﻠﻴﺪ ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺳﻄﺢ ﻭﻟﺘﺎژ ﺑﺎﻃﺮﻱ ﺩﺭ ﺣﺎﻟﺖ ﻗﻄﻊ ﻣﺪﺍﺭ ﺷﺎﺭژﺭ 9 ﺍﻧﺪﺍﺯﻩ ﮔﻴﺮﻱ ﺟﺮﻳﺎﻥ ﻭﻟﺘﺎژ ﺿﺮﻳﺐ ﺗﻮﺍﻥ ﻛﺎﻧﺘﺮ Elemote FRTU ﻣﻘﺪﺍﺭ ﻭﺍﻗﻌﻲ ﺟﺮﻳﺎﻥ :ﺟﺮﻳﺎﻥ ﻓﺎﺯ 1ﻭ 2ﻭ3 ﺩﻗﺖ 1 :ﺁﻣﭙﺮ ﺑﻪ ﺍﺯﺍﻱ FullScale ﻣﺤﺪﻭﺩﻩ ﺟﺮﻳﺎﻥ ﻭﺭﻭﺩﻱ 6-1000 :ﺁﻣﭙﺮ ﻣﻘﺪﺍﺭ ﻭﺍﻗﻌﻲ ﻭﻟﺘﺎژ :ﻭﻟﺘﺎژ ﻓﺎﺯﻫﺎﻱ a,b,c,r,s,t ﺩﻗﺖ ± 0/5% : ﻓﺎﺯ ، Aﻓﺎﺯ ، Bﻓﺎﺯ Cﻭ ﻣﻴﺎﻧﮕﻴﻦ ﺳﻪ ﻓﺎﺯ ﺗﻌﺪﺍﺩ ﺭﺍﻩ ﺍﻧﺪﺍﺯﻱ ﻣﺠﺪﺩ CPU ﺗﻌﺪﺍﺩ ﺑﺎﺯ ﺷﺪﻥ ﻛﻠﻴﺪ ﺗﻌﺪﺍﺩ ﺧﻄﺎﻫﺎ 10 ﻣﺸﺨﺼﺎﺕ ﻋﻤﻮﻣﻲ ﻣﻨﺒﻊ ﺗﻐﺬﻳﻪ ﻭﺭﻭﺩﻱ ﻣﻨﺒﻊ ﺗﻐﺬﻳﻪ FRTU ﺑﺎﻃﺮﻱ ﻭﺭﻭﺩﻱ ± 0/10% : ACﻭ 220 ± 0/5%ﻭﻟﺖ ﺑﺎ ﻓﺮﻛﺎﻧﺲ 50ﻫﺮﺗﺰ ﺧﺮﻭﺟﻲ ﺗﺮﺍﻧﺴﻔﻮﺭﻣﺮ 25 :ﻭﻟﺖ 200 ، ACﻭﻟﺖ ﺁﻣﭙﺮ ﻭﻟﺘﺎژ ﻭﺭﻭﺩﻱ 30 :ﻭﻟﺖ AC ﻭﻟﺘﺎژ ﺧﺮﻭﺟﻲ 24 :ﻳﺎ 48ﻭﻟﺖ DC ﻭﻟﺘﺎژ ﺷﺎﺭژ ﺑﺎﻃﺮﻱ 27 :ﻳﺎ 55ﻭﻟﺖ ﺧﺮﻭﺟﻲ 12 :ﻭﻟﺖ DC ﻇﺮﻓﻴﺖ 18 :ﺁﻣﭙﺮ ﺑﺮ ﺳﺎﻋﺖ ﺩﺭ ﺩﻣﺎﻱ 25ﺩﺭﺟﻪ ﺳﺎﻧﺘﻴﮕﺮﺍﺩ ﻋﻤﺮ ﺑﺎﻃﺮﻱ 24 :ﺳﺎﻋﺖ ﺑﺪﻭﻥ ﺗﻐﺬﻳﻪ AC ﺳﻮﺋﻴﭻ ﻛﻠﻴﺪ 100 :ﺑﺎﺭ ﺑﺪﻭﻥ ﺗﻐﺬﻳﻪ AC ﺯﻣﺎﻥ ﺷﺎﺭژ ﺷﺪﻥ 10 :ﺳﺎﻋﺖ ﻣﻨﺒﻊ ﺗﻐﺬﻳﻪ RTU 24ﻭﻟﺖ DC Plugin ﺗﻮﺍﻥ ﻣﺼﺮﻓﻲ 50 :ﻭﺍﺕ ﻣﻨﺒﻊ ﺗﻐﺬﻳﻪ ﻣﻮﺩﻡ ﻫﻴﺘﺮ ﺩﻣﺎﻱ ﻛﺎﺭ ﺭﻃﻮﺑﺖ ﺍﺑﻌﺎﺩ ﻭﺯﻥ Elemote FRTU 13/8 – 24ﻭﻟﺖ DC ﺳﻮﻛﺖ 48ﭘﻴﻦ ﺳﻮﻛﺖ 32ﭘﻴﻦ -30ﺗﺎ 60ﺩﺭﺟﻪ ﺳﺎﻧﺘﻴﮕﺮﺍﺩ ≤95%RH ﺗﺎﺑﻠﻮ ) 70*65*27 cm2 :ﺍﺭﺗﻔﺎﻉ*ﻋﺮﺽ*ﻃﻮﻝ( ) 27*16*14 cm2: PLCﺍﺭﺗﻔﺎﻉ*ﻋﺮﺽ*ﻃﻮﻝ( ﺗﺎﺑﻠﻮ 40 :ﻛﻴﻠﻮﮔﺮﻡ 2/7 : PLCﻛﻴﻠﻮﮔﺮﻡ 11 ﭘﻮﺭﺕ ﻫﺎﻱ ﺍﺭﺗﺒﺎﻃﻲ: ﭘﻮﺭﺕ)RS-232 (1 ﭘﻮﺭﺕ)RS-232 (2 ﭘﻮﺭﺕ)ETHERNET (3 ﺭﺍﺑﻂ ﺳﺮﻳﺎﻝ ﺍﺭﺗﺒﺎﻃﻲ ﺑﺎ ﻣﺮﻛﺰ ﺍﺳﻜﺎﺩﺍ ﭘﺮﻭﺗﻜﻞ DNP3 : ﺳﺮﻋﺖ ﺍﻧﺘﻘﺎﻝ ﺩﺍﺩﻩ 1200 – 19200 Bit/S: ﺁﺩﺭﺱ 0 – 65534 : Master ﺁﺩﺭﺱ 0 – 65534 : Slave ﻧﻮﻉ ﻛﺎﻧﻜﺘﻮﺭ :ﻛﺎﻧﻜﺘﻮﺭ ﻣﺎﺩﮔﻲ DB9 ﺭﺍﺑﻂ ﺳﺮﻳﺎﻝ ﺟﻬﺖ ﺗﻨﻈﻴﻤﺎﺕ ﻭ ﭘﻴﻜﺮﻩ ﺑﻨﺪﻱ ﺳﻴﺴﺘﻢ ﻭ ﺗﺨﻠﻴﻪ ﺩﻳﺘﺎ ﺫﺧﻴﺮﻩ ﺷﺪﻩ ﭘﺮﻭﺗﻜﻞ Modbus : ﺳﺮﻋﺖ ﺍﻧﺘﻘﺎﻝ ﺩﺍﺩﻩ 1200 – 19200 Bit/S: ﻧﻮﻉ ﻛﺎﻧﻜﺘﻮﺭ :ﻛﺎﻧﻜﺘﻮﺭ ﻣﺎﺩﮔﻲ DB9 ﺭﺍﺑﻂ ﺷﺒﻜﻪ ﺍﺭﺗﺒﺎﻃﻲ ﺑﺎ ﻣﺮﻛﺰ ﺍﺳﻜﺎﺩﺍ ﭘﺮﻭﺗﻜﻞ Modbus Over TCP/IP ، DNP3 Over TCP/IP : ﺳﺮﻋﺖ ﺍﻧﺘﻘﺎﻝ ﺩﺍﺩﻩ 10 – 100 Mb/S: ﻧﻮﻉ ﻛﺎﻧﻜﺘﻮﺭ :ﻛﺎﻧﻜﺘﻮﺭ RJ45 Elemote FRTU 12 13 Elemote FRTU 14 Elemote FRTU 15 Elemote FRTU 16 Elemote FRTU 17 Elemote FRTU 18 Elemote FRTU ﺁﺩﺭﺱ : ﻣﺸﻬﺪ .ﺧﻴﺎﺑﺎﻥ ﺁﺑﻜﻮﻩ .ﺑﻌﺪ ﺍﺯ ﺗﻘﺎﻃﻊ ﻛﻼﻫﺪﻭﺯ .ﺭﻭﺑﺮﻭﻱ ﺑﺎﻧﻚ ﺻﺎﺩﺭﺍﺕ .ﭘﻼﻙ .440ﺷﺮﻛﺖ ﻣﻬﻨﺪﺳﻲ ﺯﺭﻳﻦ ﺳﺎﻣﺎﻧﻪ ﺷﺮﻕ ﺗﻠﻔﻦ: 5 – (0511)8422323ﺧﻂ ﭘﺴﺖ ﺍﻟﻜﺘﺮﻭﻧﻴﻜﻲ : Elemote FRTU [email protected] 19
© Copyright 2025