GC2/GH2/GM2/GS2 Series Instruction Manual WARNING

GC2/GH2/GM2/GS2 Series
Dimensions
Address:
Contact :
E-mail :
Web
:
37-7 Chuo-cho, 2-Chome
Meguro-ku, Tokyo 152-0001 Japan
Tel: +81-3-37165151
Fax: +81-3-37104552
[email protected]
http://www.lineseiki.com
2
0: Terminal Block
Input
0: Switch/Open Collector Input
1: Wide Range Voltage Input
Reset
0: Remote
1: Remote & Front
INPUT
GC2 TOTALIZER
GH2 HOURMETER
6/8 Digits, 7-Segment LCD
10.6mm (H)
0 - 999999 / 0 - 99999999
Switch / Open Collector
Wide Range Voltage
GM2 MINUTEMETER
WEIGHT
WIRING
COMPLIANCE
10.6
24.8
29
Terminal No.
1 2 3 4 5
Input
1
2
3
4
5
Wide Range Voltage Input Type
Reset
Input
Vcc
2
3
4
5
Reset
GND
GND
GND
1
GND
Vcc
GS2 SECONDMETER
6 Digits, 7-Segment LCD 10.6mm (H)
1. Please install the device in the correct panel cut-out size.
2. A gasket is included with the device.
Insert the gasket in the device before inserting it in the panel.
3. Insert the mounting clip to the back of the device.
4. Push the mounting clip until it locks the device tightly against the panel.
0.0 - 99999.9
L: < 0.8V H: < 2 - 30V
Sink Current:
8 A
L:DC / AC 0 - 5V
Input Impedance: 300kW
H:DC / AC 20 - 250V
Gasket
Battery Replacement
1 count per 1/10 hour
Front Reset
Remote Reset
Mounting Clip
Panel
20Hz
(Wide Range Voltage Input Only)
1 count per 1/10 minute
1 count per 1/10 second
L: < 0.8V H: < 2 - 30V Sink Current:
8 A
L:DC/AC 0 - 5V
Input Impedance: 300kW
H:DC/AC 20 - 250V
6ms minimum
RESET PULSEWIDTH
3.6V 1/2AA Lithium Battery (replaceable), 7 years min. with continuous input at 25°C *The battery life is not a guaranteed value.
POWER
Electrostatic Discharge:
IEC-61000-4-2 8kV
NOISE IMMUNITY
Electromagnetic Field:
IEC-61000-4-3 10V/m
EFT/BI/O Leads:
IEC-61000-4-4 1.0kV
EMI: EN50081-2
EMS: EN50082-2
EMC STANDARD
-10 - +55°C (Should not be Frozen)
AMBIENT TEMP. : OPERATING
)-20 - 65°C (Should not be Frozen)
AMBIENT TEMP. : STORAGE
-- 85% RH (Non-Condensing)
25
AMBIENT HUMID. : OPERATING
Operation
:
Single
Amplitude
0.35mm,
Frequency: 10 - 55Hz, X, Y, Z Axis (3 Axis) / 100m/s2
VIBRATION /
SHOCK RESISTANCE
Storage : Single Amplitude 0.75mm, Frequency: 10 - 55Hz, X, Y, Z Axis (3 Axis) / 300m/s2
ALTITUDE
INSTALLATION ENVIRONMENT
PROTECTION
49.8
11
Mounting
RESOLUTION
RESET
38.3
Panel Cut Dimension
30 Hz
COUNT SPEED
3.5
6: 6 Digits
Display
8: 8 Digits (GC2 only)
Specifications
DISPLAY DIGIT
Terminal No.
Wide Range Voltage Input Type
50 +0.7
+0
3.8
Switch/Open Collector Input
Wiring
C: Totalizer
H: Hourmeter
M: Minutemeter
S: Secondmeter
DISPLAY
49.8
6.5
Wiring
G
TYPE
6 Digit
8 Digit
Models
Type
10.2 12.6
LINE SEIKI CO., LTD.
38.3
24.8
Panel mount(50.0 x 25.0mm)
6 / 8 digits LCD display
Lithium battery included
Battery life 7 years
IP54 Front Panel protection level
In conformance to CE (EMC),
RoHS and UL 863
3.5
1 2 3 4 5
25 +0.7
+0
Customer Service
Main Features
4.8
10.6
WARNING
Thank you for purchasing this Line Seiki product.
Please read this instruction manual carefully before using to ensure correct
usage of this product.
Please keep this instruction manual for future reference.
Please note that misuse of this device
may lead to injury to the user or
damage to the device.
Switch/Open Collector Input Type
54
43.2
Digit Dimension
Instruction Manual
ATTENTION!!!
Precautions when replacing the battery:
- Disconnect the wiring before changing the battery. Do not touch areas
subject to high voltages, this could result to an electric shock.
- Make sure that your body is free from static electricity before changing
the battery.
- Make sure to follow carefully the procedures described below.
Switch/Open Collector
Wide Range Voltage
1) Remove the terminal block from the main device. (except wide range
voltage input type)
2) Use a flat screwdriver or any appropriate tool to lift the groove in order
to disconnect the 'front and back' case hooks.
3) Pull out the back case from the main body.
4) Replace with a new battery making sure that the positive and negative
terminals of the battery are positioned correctly.
5) Replace the back case to the main body.
Make sure that the case hooks click properly in place.
*Please use 3.6V 1/2AA Lithium Battery only for this device.
WARNING!
2,000m max.
Over-voltage category II , Pollution degree 2 (IEC61010-1)
IP54
60g (Battery included)
14-22 AWG Leadwires by Terminal Screw
RoHS, UL863, CE
EXPLOSIVE!
This device uses Lithium battery, it must be disposed properly after use.
Do not short the positive and negative terminals, recharge, disassemble, deform by the application of
excessive pressure, or dispose the battery to fire as this may seriously damage it or may cause explosion.
Do not attempt to disassemble or modify this device.
Mount to the front panel when using this device. (Indoor use)
Do not use organic solvents such as thinners etc. to clean the front panel.
Internal circuit may be destroyed if a voltage outside the rated voltage is applied.
This manual was last revised May. 23, 2014. 4GX2001E
*Subject to change without prior notice.
All Rights Reserved,Copyright © 2014,LINE SEIKI CO.,LTD.