Alaris TIVA syringe pump TIVA syringe pump

Alaris TIVA syringe pump
Specifications
®
Alaris TIVA
syringe pump
®
Rate Range
5ml syringe
10ml syringe
20ml syringe
30ml syringe
50ml syringe
–
–
–
–
–
0.1 to 150 ml/h
0.1 to 300ml/h
0.1 to 600ml/h
0.1 to 900ml/h
0.1 to 1200ml/h
–
–
–
–
–
max bolus rate 150ml/h
max bolus rate 300ml/h
max bolus rate 600ml/h
max bolus rate 900ml/h
max bolus rate 1200ml/h
Alaris Products
®
Volume Infused
0.0 - 9990ml
Bolus Rate
5ml syringe
10ml syringe
20ml syringe
30ml syringe
50ml syringe
Dose Rate Units Available
ml/h, ng/min, ng/kg/min μg/min, μg/kg/min, μg/h, μg/kg/h,
μg/24h,μg/kg/24h mg/min, mg/kg/min, mg/h, mg/kg/h,
mg/24h, mg/kg/24h,g/h, g/24h, U/min, U/kg/min, U/h, U/kg/h,
U/24h, U/kg/24h,kU/24h, mmol/h
Purge Rate
100 ml/h - 500 ml/h (limited to size of syringe) limit 0.5 - 5.0 ml
Accuracy
Volumetric +/- 2% (nominal)
Syringe Type
5 ml, 10 ml, 20 ml, 30 ml or 50 ml disposable syringe of type
specified on pump
Battery Type
Rechargable sealed NiMH, automatically charged when pump is
connected to AC power
Battery Life
Battery life is typically 6 hours from full charged battery
(5 ml/h @ 20°C under normal conditions) Consult operating
instructions.
Recharge Time
21/2 hours from discharge to 90% charge
Pumping Pressure Limits
Highest alarm level: 1000 mm Hg (L-10), Factory Preset: 300 mm
Hg (nominal L-3)
Occlusion levels L-0 to L-10.
Alarms
Audible alarm and display prompts with comprehensive
protection for:
• Pressure limit exceeded
• Drive disengaged
• Infusion complete
• Purge/Bolus activated
• Nurse CallBack
• Near end infusion
• Battery low
• AC power failure
• Syringe clamp
AC power requirements
115-230 VAC, 50/60 Hz. 20 VA (nominal)
CareFusion Australia 316 Pty Ltd
Unit 3/167 Prospect Highway
Seven Hills
NSW 2147
Australia
+61 2 9624 9000 tel
+61 2 9624 9034 fax
CareFusion NZ 313 Ltd
14B George Bourke Drive
Mt. Wellington
Auckland
New Zealand
+64 9 270 2420 tel
0508 422734 freephone
+64 9 270 6285 fax
CareFusion
Solbråveien 10A
1383 Asker
Norway
+47 66 98 76 00 tel
+47 66 98 76 01 fax
CareFusion International Headquarters
A-One Business Centre
Zone d’activitiés Vers-la-Pièce no 10
1180 Rolle
Switzerland
+41 21 556 30 00 tel
+41 21 556 30 99 fax
CareFusion
Unit 2 Oude Molen
Business Park
Oude Molen Road
Ndabeni
Cape Town 7405
South Africa
+27 21 510 7562 tel
+27 21 510 7567 fax
CareFusion
Hammarbacken 4B
SE-191 24 Sollentuna
Sweden
+46 8 544 43 200 tel
+46 8 544 43 225 fax
© 2009
© 2010
CareFusion
CareFusion
Corporation
Corporation
or one
or one
of its
ofsubsidiaries.
its subsidiaries.
All rights
All rights
reserved.
reserved.
Alaris
Alaris
is a registered
and Smartsite
trademark
are registered
of CareFusion
trademarks
Corporation
of CareFusion
or oneCorporation
of its subsidiaries.
or
0000CF00146
one of its Issue
subsidiaries.
1
0000CF00379 Issue 1
Dimensions
310 mm (w) x 121 mm (h) x 200 mm (d)
Weight (nominal)
2.7 kg
Standards
EN60601-1, EN60601-1-2, EN60601-2-24
CareFusion UK
The Crescent
Jays Close
Basingstoke
Hampshire RG22 4BS
United Kingdom
0800 917 8776 freephone
+44 (0)1256 330860 fax
carefusion.com
Alaris TIVA syringe pump
Safety Disposables
®
The perfect
partner for IV
anaesthesia
Portability
System Integration Capability
Alaris syringe pumps are portable independently of the
When docked to an Alaris ® Gateway Workstation,
Alaris ® Medication Safety System. With all features available
your complete infusion system has the capability to
on the move and safety and intelligence built in.
link to Patient Data Management Systems (PDMS) and
®
Refer to Disposables Catalogue for the full range of
illustrated products
TIVA sets
500-002
• Y extension 2 way • 1 Back-check valve
• 15cm • 1 Anti-siphon valve
500-003
• Y extension 3 way • 1 Back-check valve
• 2 Anti-siphon valves
• 15cm
500-012
• Y extension 2 way extension set • 220cm
• 1 Anti-siphon valve • 1 Back-check valve
500-013
• Y extension 3 way extension set • 190cm
• 1 Back-check valve • 2 Anti-siphon valve
MFX2270
• Y extension 3 way • 3 Back-check valves • 2 Antisiphon valves • 2 Roberts clamps • 5.2ml* • 210cm
MFX2271
• Extension line • 2 Back-check valves • Anti-siphon
valve • Roberts clamp • 3.0ml* • 210cm
MFX2290
• Y extension 3 way • 3 Back-check valves • 2 Antisiphon valve • Roberts clamps • 4.3ml* • 209cm
MFX2291
• Y extension line • 2 Back-check valves 2.3ml*
• 209cm
MFX2292E
• Y extension 3 way • SmartSite Valve • 3.9ml*
• 210cm • 4 Back-check valves
• 2 Anti-siphon valves
Hospital Information Systems (HIS) through our open
network architecture.
®
Y connectors
®
20038E
• Y connector 3 way • 3 SmartSite Valves
• 3 Slide clamps • 0.3ml* • 11.5c
20061E
• Y connector 2 way • 2 SmartSite Valves • 2 Slide
clamps • 1.8ml* • 18cm • 2 Back-check valves
20062E
• Y connector 3 way • 3 SmartSite Valves
• Back-check valve • 3 Slide clamps • 1.5ml* • 16cm
MFX2233E
• Y connector 3 way
®
• SmartSite Valve • 0.6ml*
• 10cm • 2 Back-check valves
®
®
Extension lines
Pre-programmable drug protocols
Pressure settings
100 pre-programmable drug protocols with on-screen
11 pressure settings - lets you select the appropriate
verification before infusion starts.
pump pressure for each infusion.
G40615
• Extension line • Low sorbing • 1.5ml* • 150cm
G40620
• Extension line • Low sorbing • 2ml* • 200cm
G40720
• Extension line • Roberts clamp • Low sorbing
• 1.5ml* • 200cm
MFX2256
• Extension • Lipid resistant • 0.9ml* • 205cm
MFX2260
• Extension line • Anti-siphon valve • 0.63ml* • 200cm
MFX2280E
• Stopcock extension • SmartSite Valve
• Lipid resistant • 1ml* • 10cm
MFX2284
• Stopcock extension • Lipid resistant • 7.2ml*
• 100cm
MFX2285
• Stopcock extension • Lipid resistant • 8.6ml*
• 120cm
®
Accessories
2000E7D
®
• SmartSite Valve • 0.1ml* • 2.5cm
(2000E in Australia/New Zealand)
2203E
2205E
The Alaris ® TIVA syringe pump helps to administer IV anaesthesia
drugs – so you can concentrate on improving patient care.
• Simple to set up
2300E
• Faster set-up of infusion parameters
• Portable
• Pre-programmable drug protocols
Bolus dose facility
Event log
A range of bolus rates can be selected. “Hands-free”
Easy access to a comprehensive event log, which allows
infusion bolus doses can be adjusted, allowing the
for a review of events recorded in real time.
anaesthetist to focus on the needs of the patient.
2309E
MFX1594E
30602N
®
• SmartSite Valve vial access device (13mm vials)
• 0.08ml* • 3.3cm
®
• SmartSite Valve vial access device (20mm vials)
• 0.08ml* • 3.7cm
®
• Bag spike • Unvented • SmartSite Valve 0.46ml*
• 8.33cm
®
• Bag spike • Unvented • SmartSite Valve
Backcheck valve • 0.86ml* • 12.5cm
®
• Dispensing pin • SmartSite Valve
• 0.2µm hydrophobic filter • 0.1ml* • 6.5cm
®
• IVAC 50 ml Syringe
* Priming volume
Illustrations are only to be used as a guide and do not necessarily depict a true representation