Hz Wireless Radio Switches and Receivers Items Reference Description Single Channel Surface Wall Mount 2005713 -Available in white -Indoor rated Slim Single Channel Hand Held 2006138 2006139 2006140 2006141 2006142 White Silver Plum Green Orange Slim Multi Channel Hand Held 2006143 2006144 2006145 2006146 2006147 White Silver Plum Green Orange 1810603 White Recessed Designer Single Channel -5 independent channels that can be programmed to operate one or more motors. -Indoor rated 1810604 Ivory 1810605 White 1810606 Ivory Recessed Designer Multi Channel -5 independent channels that can be programmed to operate one or more motors. -Indoor rated Two Channel Key Chain Style Transmitter 2005326 -Available in black -Sequence function Four Channel Key Chain Style Transmitter 2005914 -Available in black -Sequence function 43 Hz Wireless Radio Switches and Receivers Items Reference Description Hz Radio Timer 2004960 -Compatible with all Hz radio operators. This timer can operate multiple operators automatically at a set time. -Indoor use only. Hz Radio Key Pad 2006029 -Compatible with all Hz radio operators. This key can operate two independent Hz radio operators. -IP 54 Outdoor weather rated. Hz Radio Dry Contact Transmitter 2005714 -This transmitter is designed to link Hz operators into most home automation systems. Hz Radio Receiver Motor Controller 1810602 -This radio receiver can be used with the SIMU standard AC motor series T3.5, T5, T5DMI,T6, T6DMI, T8 and T8 override. This control is compatible with all the transmitter switches shown above. No job is too large or small for the Hz wireless technology which is the latest radio innovation from SIMU. It combines the function of wireless switching with the added benefit of group control directly into the operator. Everything from individual switching and sub grouping to a master control can be accomplished without the use of external controls. For more details on this product please refer to the Hz control manual which features detailed information on wiring and program scenarios. Note: This radio control system is not compatible with the RC200 sequence controlled radio. 44 Sequence Controlled Radio Radio Receiver and Transmitter Controls This radio remote control is everything you need to operate your SIMU operator. It's new designer look is stylish, compact and water resistant. Built-in reliable features include sequence controlled switching, remote location switching ability, run timer with automatic shut-off and dry contact safety control hook-up. The designer remote complies with Part 15 of the FCC Rules and can transmit over 300 feet. Reference Description 2005642 2005643 2005644 Transmitter-Two Channel Transmitter-Four Channel Transmitter-Twelve Channel 2005632 2005634 Receiver (120V-60Hz) surface wall mount Receiver (Dry contact hook-up) Note: This radio control system is not compatible with the Hz wireless control products. Wiring for one motor and one RC200 receiver RC200 Receiver PW 1 2 LD NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 CODE MEMORY CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Fuse 4.0A 2 Terminal capacity: #14 AWG to #10 AWG 3 4 6 5 7 1 Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. 12 8 9 13 10 11 45 WHITE BLACK RED GREEN Antenna JUMPER 1 - Ground (Green) 2 - Ground (Green) POWER IN 120VAC 3 - Neutral GROUND 4 - Hot 120VAC NEUTRAL 5 - Direction 1 ( Black ) HOT 6 - Direction 2 (Red) 7 - Common (White) *8 & 9 N. C. Reversing Sensor 10 & 11 Remote Override Switch (SPBS) 12 - Coax Antenna Connection ( not supplied ) 13 - Standard Antenna ( supplied with unit ) NOTE: - If you are not using a safety device a jumper wire must be connected to terminals 8 & 9. - Do not cut antenna wire supplied with this unit. - See complete instructions supplied with unit on transmitter programming. M N.O. SINGLE POLE SINGLE THROW SWITCH (REF#SPBS) Operator Electronic Control Systems Automatic Environmental Controls The Halcomaster 2200 is a control system for all types of window treatments. Whether you are controlling retractable awnings, rolling shutters or sun shades, the Halcomaster 2200 enables a window treatment to provide shading from the sun and protection from the wind automatically and conveniently. A digital display read out allows you to monitor the sensors sun intensity and wind speed levels. These settings can be adjusted easily from the control unit. SET halcomaster R 2200 Reference Unit Function 2279073 2279193 2279194 Sun and Wind Control (white - surface mount) Sun and Wind Control (ivory - 3 gang recessed mount) Sun and Wind Control (white - 3 gang recessed mount) 2279055 2279010 2279139 2279058 2279054 Replacement / Additional Sun Sensor Replacement / Additional Rain Sensor Replacement / Additional Temperature Sensor Replacement / Additional Wind Sensor Replacement / Additional Sensor Bracket The Halcomaster 2200USPRO allows for additional sensors to be attached. It also allows for additional switches to be remotely located. Wiring for one motor and one 2200PRO NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Terminal capacity: #14 AWG to #10 AWG Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. Green (Ground) Neutral Hot (120V-60Hz) 2200-LO SUN SENSOR + - R M 46 White Green Jumper Black Red 2200-RM RAIN SENSOR OPTIONAL 2200-WM WIND SENSOR Operator Electronic Control Systems Automatic Environmental Controls WINDY 120V - 60Hz The WINDY is designed to retract a motorized awning or sun shade during windy conditions, whether your home or away. The WINDY can also be used to close other window treatments such as rolling shutters during those same windy conditions. The wind sensor is adjustable and the automatic wind protection function is designed to override the manual switch during high wind gusts. Other features of the WINDY include the use of standard switches. Choose from designer switches, toggle switches or rocker switches. Reference Unit Function 2005721 2009089 Wind Control for Awnings and Shades Wind Control for Rolling Shutters * WARNING THE “SWITCH COM” IS AN INTERNALLY PROVIDED HOT (115VAC) POWER AND IS ONLY CONNECTED TO COMMON TERMINAL OF THE SWITCH. DO NOT CONNECT TO ANY EXTERNAL VOLTAGE SOURCE (LINE POWER: HOT OR NEUTRAL) AS THIS WILL CAUSE SEVERE DAMAGE TO THE CONTROL. Wiring for one motor and one Windy NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Wind Meter Terminal capacity: #14 AWG to #10 AWG Wind Speed Adjustment CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. Motor Switch 120V * N Com N L Black White Red * NOTE: Turn the wind speed adjustment down to minimum. Spin the wind sensor and confirm the windy activates in the correct direction. If the windy activates the motor in the wrong direction at a wind signal, reverse the red and black motor leads. Remember to turn the wind speed adjustment back up after testing. Individual Switch M Neutral Green (Ground) 47 Hot (120V-60Hz) Operator Electronic Control Systems Group Control Relays Sub Group Switch Master Switch Individual Switch Individual Switch Individual Switch Individua all Switch Individual Swiittch GI.2 RI.3 Individual Switch Individual Switch RI.2 Relay group controls can be linked together to control any amount of operators. SIMU can custom design a group control system that will give you complete control of your SIMU operators. Reference Unit Function 2282074 2282075 2282028 2282018 Two Motor Relay Group Control (master, individual) (RI.2) Three Motor Relay Group Control (master, individual) (RI.3) Two Motor Relay Group Control (master, sub group, individual) (GI.2) Two Motor Relay Group Control (24-Volt switching) (RG.2) 2005718 2005719 2005717 Two Motor Relay Group Control (master, individual) Metal Box (RI.2M) Three Motor Relay Group Control (master, individual) Metal Box (RI.3M) Two Motor Relay Group Control (24-Volt switching) Metal Box (RG.2M) NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. Ground (Green) CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Hot Power L1 (Black) Common N (White) Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Terminal capacity: #14 AWG to #10 AWG Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. M Motor P Power to Ind. Switch Motor Direction (Red/Black) Note: Connections are only at terminals 48 Operator Electronic Control Systems Wiring Relays RI.2 N N N N CENTRAL 115V - 60Hz N N L L POWER IN 115VAC GROUND Individual Switch Individual Switch Master Switch RI2 5AMP MAX * Two Motors * One Momentary Master Switch * Two Momentary Individual Control Switches N INDIVIDUAL SWITCH INDIVIDUAL SWITCH M M N N N CENTRAL Individual Switch Individual Switch Individual Switch N 115V - 60Hz P N N L L POWER IN 115VAC GROUND RI3 Master Switch RI.3 P 5AMP MAX * Three Motors * One Momentary Master Switch * Three Momentary Individual Control Switches 49 P P P INDIVIDUAL SWITCH INDIVIDUAL SWITCH INDIVIDUAL SWITCH M M M Operator Electronic Control Systems Wiring Relays Mp GI2 115V - 60Hz Individual Switch Individual Switch Master Switch GI.2 P 120V P P M M 115v Mp Mp * Two Motors * One Momentary Master Switch * One Momentary Sub Group Switch * Two Momentary Individual Control Switches NEUTRAL HOT GROUND M2 M1 RG.2 L L NNN 120VAC POWER 115V - 60Hz N MOTOR1 MOTOR2 24VDC 0.1AMPS PER RG2 IN GROUP Individual Switch Individual Switch Master Switch FUSE 5AT RG-2 MOTOR 1 SWITCH P Individual switches can be linked to form a subgroup * Two Motors * Low-Voltage Momentary Master Switch * Two Low-Voltage Momentary Individual Control Switches Master Control (AV or switch) 50 MASTER SWITCH BUS LINE (CENTRAL) MOTOR 2 SWITCH P Individual switches can be linked to form a subgroup Operator Electronic Control Systems Low Voltage Battery Back-up System Never be without POWER! Power On Line STOP Power Off Line Low Battery The BBU is designed to provide you with constant power to any SIMU DC operator. The BBU operates from a battery that is charging while standard AC current is available. Three LED lights on the front of the unit keep you informed on your current power conditions. The unit also has additional dry contact connections for external switching devices such as home automation systems. Reference Wiring for one DC motor and one BBS Unit Description 2005715 2005716 Battery back up system with warning lights (white) Battery back up system with warning lights (ivory) 2005586 Battery Replacement 12v 1.2 amp hour NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Terminal capacity: #14 AWG to #10 AWG CONNECT TO ALL BBU’S IN A GROUP L external switches control only this BBU JP1 TECHNICAL DATA: Input Voltage Input Current Motor Output Voltage Motor Output Current Battery Output Standby Battery Current Shut Down Battery Current Size External Switching Bus Line 120 VAC 50/60Hz 50 mA 12 Volts Nominal 5 Amps Max. Polyfused Voltage/Current Regulated Charging for 12 Volt 1.2 Ah Sealed Lead Acid Battery, 6.5 mA .9mA 3.5“ X 2.5” (Fits in deep 2 gang plastic box supplied) N.O., Momentary Dry Contacts Rated for 12 Volts 12 Volts DC Jumpers on Jumpers off external switches control all BBUs connected by bus line MASTER/LOCAL SWITCH JUMPER + RED + _ MOTOR BLACK - BATTERY 12VOLT 1.2 Ah REF#2005586 51 N BUS LINE EXTERNAL SWITCH MASTER/LOCAL MASTER LOCAL JP1 UP DOWN STOP COMMON LINE POWER 120VAC (G) GROUND (L) LINE (N) NEUTRAL JP1 U D S +12 U D S +12 U D S G SWITCH BUS EXTERNAL SWITCH G REF# BBU Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. Motor Wire 16 gage min. 20 foot max length BROWN BLUE Operator Electronic Controls Security Key Switches Items Reference Description Single Pole, Double Throw, Maintained Contact 2001547 -Surface mount * 3 keys included. 2001549 -Recessed mount Single Pole, Double Throw, Momentary Contact 2001548 -Surface mount * 3 keys included. 2001550 -Recessed mount Single Pole, Single Throw, Momentary Contact 2001551 -Surface mount * 3 keys included. 2001552 -Recessed mount Commercial Grade Single Pole, Double Throw, Momentary Contact 2005616 -Surface mount * 3 keys included. Commercial Grade Single Pole, Double Throw, Momentary Contact 2005614 -Recessed mount * 3 keys included. 2005752 Standard Key Switch Extra Keys 2005613 Commercial Grade Extra Keys 52 Operator Electronic Controls Security Key Switches Motor Black (Key Switch) Motor Black Motor Black Motor Red Motor Black Green (Ground) White (Neutral) Hot (120V-60Hz) (Key Switch) Green (Ground) White (Neutral) Black ( Hot 120V-60Hz) Motor Red Black ( Hot 120V-60Hz) Green (Ground) Jumper wire Key Switch Key Switch * One Motor * One Key Switch * One Motor * One Key Switch Reference Numbers 2001548 - Momentary key switch, surface mount 2001550 - Momentary key switch, recessed mount Reference Numbers 2001547 - Maintained key switch, surface mount 2001549 - Maintained key switch, recessed mount Wiring for one motor and one key switch switch NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Motor Black (Key Switch) Terminal capacity: #14 AWG to #10 AWG Blue Yellow Motor Black Motor Red Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. Orange Orange Green (Ground) White (Neutral) Hot (120V-60Hz) Warning * One Motor * One Key Switch DO NOT wri e more than one operator to a single pole swti ch. A second operator can be wired to the second pole of a double pole switch. Reference Numbers 2005616 Momentary key switch, surface mount 2005614 Momentary key switch, recessed mount DO NOT connect two swti ches to an operator without a relay. Key Switch 53 Operator Electronic Controls Designer Switches Designer Cover Plates Reference Description 2005553 2005558 2005526 Designer Switch - Single Pole, Double Throw (Maintained - Ivory) Designer Switch - Single Pole, Double Throw (Momentary - Ivory) Designer Switch - Double Pole, Double Throw (Maintained - Ivory) 2005554 2005559 2005527 Designer Switch - Single Pole, Double Throw (Maintained - White) Designer Switch - Single Pole, Double Throw (Momentary - White) Designer Switch - Double Pole, Double Throw (Maintained - White) 2005549 2005555 2005525 Designer Switch - Single Pole, Double Throw (Maintained - Almond) Designer Switch - Single Pole, Double Throw (Momentary - Almond) Designer Switch - Double Pole, Double Throw (Maintained - Almond) 2005550 2005556 Designer Switch - Single Pole, Double Throw (Maintained - Black) Designer Switch - Single Pole, Double Throw (Momentary - Black) 2005532 2005536 2005539 Designer Cover Plate 1 Gang, Ivory Designer Cover Plate 2 Gang, Ivory Designer Cover Plate 3 Gang, Ivory 2005533 2005537 2005540 Designer Cover Plate 1 Gang, White Designer Cover Plate 2 Gang, White Designer Cover Plate 3 Gang, White 2005528 2005534 2005538 Designer Cover Plate 1 Gang, Almond Designer Cover Plate 2 Gang, Almond Designer Cover Plate 3 Gang, Almond 2005529 2005535 Designer Cover Plate 1 Gang, Black Designer Cover Plate 2 Gang, Black Wiring for one motor and one designer switch NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Power in Hot Neutral Ground Black White Green Motor Leads Direction 1 Direction 2 Neutral Ground Red Black White Green GREEN ( gron u d) Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Terminal capacity: #14 AWG to #10 AWG BLACK ( 120v - 6h 0 z) WHITE ( neutral ) RED direction 1 B1 Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. GREEN ( ground ) Power from wall Warning BLAK C direction 2 L1 DO NOT wri e more than one operator to a single pole swti ch. A second operator can be wired to the second pole of a double pole swti ch. A1 Items WHITE ( neutral ) DO NOT connect two swti ches to an operator wti hout a relay. 54 Operator Electronic Controls Toggle Switches Items Reference Description 2005520 2005522 2005514 Toggle Switch - Single Pole, Double Throw (Maintained - Ivory) Toggle Switch - Single Pole, Double Throw (Momentary - Ivory) Toggle Switch - Double Pole, Double Throw (Maintained - Ivory) 2005521 2005523 2005515 Toggle Switch - Single Pole, Double Throw (Maintained - White) Toggle Switch - Single Pole, Double Throw (Momentary - White) Toggle Switch - Double Pole, Double Throw (Maintained - White) 2005516 2005518 Toggle Cover Plate 1 Gang, Ivory Toggle Cover Plate 2 Gang, Ivory 2005517 2005519 Toggle Cover Plate 1 Gang, White Toggle Cover Plate 2 Gang, White Toggle Cover Plates Wiring for one motor and one toggle switch NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. Power in Hot Neutral Ground Black White Green Motor Leads Direction 1 Direction 2 Neutral Ground Red Black White Green CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Terminal capacity: #14 AWG to #10 AWG Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. GREEN ( ground ) GREEN ( ground ) Warning Powerf rom wall BLACK ( 120v - 60hz ) WHITE ( neutral ) DO NOT wri e more than one operator to a single pole swti ch. A second operator can be wri ed to the second pole of a double pole swti ch. BROWN SCREW BRASS SCREWS RED ( direction 1 ) DO NOT connect two swti ches to an operator wti hout a relay. BLACK ( direction 2 ) WHITE ( neutral ) 55 Operator Electronic Controls Rocker Switches Items Reference Reference Switch Only Switch Kit 2005598 2005600 2005682 2005684 Description Rocker Switch - Single Pole, Double Throw (Maintained - White) Rocker Switch - Single Pole, Double Throw (Momentary - White) - Switch kit includes: switch, back plate, cover plate and mounting screws Rocker Cover Plates 2005657 2005662 2005668 Rocker Cover Plate Kit 1 Gang White Rocker Cover Plate Kit 2 Gang White Rocker Cover Plate Kit 3 Gang White -Includes cover plate, back plate and mounting screws. Wiring for one motor and one rocker switch NOTICE: For installation by a qualified electrician in accordance with national and local electrical codes, and the following instructions. Power in Hot Neutral Ground Black White Green Motor Leads Direction 1 Direction 2 Neutral Ground Red Black White Green CAUTION: RISK OF ELECTRICAL SHOCK. Disconnect power before installing. Never wire energized electrical components. Select conductors having 90 C or higher rated insulation having sufficient ampacity in accordance with the 60 C column of National Electrical Code R Table 310-16 or Canadian Electrical Code Table 2 Terminal capacity: #14 AWG to #10 AWG Power from wall Strip conductors using strip gage on switch body. DO NOT USE TIN CONDUCTORS. WHITE ( neutral ) RED ( direction 1 ) BLACK ( 120v - 60hz ) BLACK ( direction 2 ) GREEN ( ground ) Warning WHITE ( neutral ) DO NOT wri e more than one operator to a single pole swti ch. A second operator can be wri ed to the second pole of a double pole swti ch. GREEN ( ground ) DO NOT connect two swti ches to an operator wti hout a relay. 56 Operator Electronic Controls Transformers and Motor Cable Items Transformers Motor Cable Reference Description 2005968 2005647 2005637 HARDWIRE - 6 AMP - 12 VOLTS HARDWIRE - 8 AMP - 12 VOLTS HARDWIRE - 10 AMP - 12 VOLTS 2005604 2005605 2005639 2005641 HARDWIRE - 6 AMP - 24 VOLTS HARDWIRE - 8 AMP - 24 VOLTS HARDWIRE - 10 AMP - 24 VOLTS HARDWIRE - 12 AMP - 24 VOLTS 9128097 2005749 3 CONDUCTORS PLUS GROUND (white) 3 CONDUCTORS PLUS GROUND (gray) 57
© Copyright 2024