Biaxial Teslameter
Features
Range : 0 to 100 mT
Accuracy : +/- 2 % of the measurement
+/- 3 UR
Analog output compatible with all
data logging systems
Dimensions : 160x75x45 mm
(6’’1/4 x 3’’ x 1’’3/4)
Item 343 002
Measurement of magnetic field in 2 directions Bx and Bz
Supplied with a graduated probe
LED Colorimeter
Features
5 wavelengths
Automatic white
Item 304 001
MORE THAN 2000 REFERENCES.
CONTACT US !
www.sciencethic.com
[email protected]
Transmission 0 to 100 %
Absorbance 0 to 3
Wavelength: blue, green, yellow,
red, purple
1-point calibration : 100 % (white)
Analog output on Ø 4 mm
Power supply : Li-ion battery with
adaptor supplied
Dimensions : 160 x 75 x 45 mm
(6’’1/4 x 3’’ x 1’’3/4)
measuring devices 59
Thermometer
-25°C / +125°C
pH Meter
Item 310 016
Item 301 010
Measure temperature from
-25°C to 125°C (-13°F to 257°F)
Automatic calibration in 2 points
Range of measure
Measure conductivity
Automatic calibration in 2 points
(pH 7, 4/10)
2 gauges : 0-2000µS.cm-1
and 0-20 mS. cm-1
THERMOMETER
PH METER
CONDUCTIVITY METER
pH from 0 to 14
0-2000µS.cm-1 / 0-20 mS.cm-1
0,1 °C
0,1 u.pH
1 µS.cm-1 / 0,01 mS.cm-1
Automatic calibration in
2 points (pH 7, 4/10)
Automatic calibration in 1 point
1413 µS.cm-1 / 12,880 mS.cm-1
Not supplied (BNC connexion)
2 probes Ø 12 mm (supplied)
Stainless steel Ø 6 mm (supplied)
Ø 4 mm – compatible with all computer data logging systems
Analogic output
Li-ion battery and adaptor
Power supply
160x75x45 mm (6’’1/4 x 3’’ x 1’’3/4)
Dimensions (LxHxD)
1
Measure pH from 0 to 14
Item 032 010
Optional from 0 to 100°C
Probe
Pressure Meter
Range of measure
Accuracy
Measuring probe
Analogic output
Item 302 008
-25,0 °C to +125°C
Accuracy
Calibration
Conductivity Meter
2
Pressure gauge
PRESSURE METER
PRESSURE GAUGE
0 to 2000 hPa
Absolute: 0-2000 hPa. Relative : 0-200 hPa
1 hPa
Absolute: 1 hPa. Relative : 0,1 hPa
1 probe Ø 3 mm
2 probes Ø 3 mm
1
Ø 4 mm – compatible with all computer data logging systems
Power supply
Dimensions (LxHxD)
Li-ion battery and adaptor
Item 311 007
160x75x45 mm (6’’1/4 x 3’’ x 1’’3/4)
2
MORE THAN 2000 REFERENCES.
CONTACT US !
Item 311 006
[email protected]
www.sciencethic.com
60 measuring devices
Joulemeter and CO2 converter
Item 342 001
Giant digital display
Features
Measure 3 variables: Power (W), Energy (J) and mass of C02 emitted (g)
Maximum voltage: 20 VAC/30 VDC
Maximum current:
4 Aac/6 Adc (protection per fuse
automatically resettable 30 V/40 A)
Maximum power : 180 W
Maximum energy : 30 000 J
Equivalent CO2 production in g
per day
Passband : 20 KHz
Resolution : 1/100 of the read value
Time : from 0s to 99h59min59s
Power supply : sector adaptor
230 V/12 V
Unique: automatic calculation of the mass of released C02
Students can measure the consumption’s characteristics of electrical connections
(instantaneous power in W, consumed energy in J) and calculate the mass
of carbon dioxide released in g.
Carbon dioxide emissions vary from one country to another depending on the
mode of electricity production (carbon, fuel oil, nuclear, hydraulic, wind or
photovoltaic energy…). The user can program this variable in the device and
calculate the mass of CO2.
The apparatus can display simultaneously the equivalent mass of CO2 released
and the power or the consumed energy.