RA12-100AD (12V100Ah) RA12-100AD is AGM Deep cycle battery with 10 years floating design life, specially designed for frequent cyclic discharge usage. By using strong grid and specific paste plate, it makes battery have 30% more cyclic life time than standby series. It is applicable for solar energy system, golf cart, electric wheelchair, etc.. Specification Cells Per Unit 6 Voltage Per Unit 12 Capacity 100Ah@10hr-rate to 1.80V per cell @25 oC Weight Approx. 29.0 Kg Max. Discharge Current 1000 A (5 sec) Internal Resistance Approx. 5 mΩ Operating Temperature Range Discharge: -20 C ~60 C Charge: 0 oC~50 oC Storage: -20 oC~60 oC Normal Operating Temperature Range 25 oC±5 oC Float charging Voltage 13.6 to 13.8 VDC/unit Average at 25 oC Recommended Maximum Charging Current Limit 30 A Equalization and Cycle Service 14.6 to 14.8 VDC/unit Average at 25 oC Self Discharge RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored o for more than 6 months at 25 C. Self-discharge ratio less than 3% per month at 25 oC. Please charge batteries before using. Terminal Terminal F5/F12 Container Material A.B.S. (UL94-HB) , Flammability resistance of UL94-V1 can be available upon request. o o Dimensions Unit: mm Terminal F12 Dimension: 328(L)×172(W)×222(H) Terminal F5 Constant Current Discharge Characteristics: A (25 oC) F.V/Time 9.60V 5MIN 320.7 10MIN 226.9 15MIN 18 1.4 30MIN 112 .7 1HR 65.00 2HR 38.8 9 3HR 2 6.88 4HR 22.03 5HR 18.03 8HR 12.4 2 10HR 10 .50 20HR 5.777 10.0V 311.4 215.8 17 7.7 110 .8 64.70 38.6 0 2 6.78 21.93 17.93 12.3 2 10 .40 5.672 10.2V 302.2 208.2 17 4.9 109 .8 64.10 38.3 1 2 6.57 21.83 17.82 12.2 2 10 .30 5.567 10.5V 271.3 192.1 16 6.5 107 .1 63.50 38.0 2 2 6.47 21.62 17.61 12.1 2 10 .20 5.462 10.8V 244.9 175.2 15 3.5 102 .4 62.00 37.3 3 2 5.75 21.11 17.29 11.9 2 10 .10 5.357 11.1V 209.1 156.6 13 7.7 95.91 58.90 35.6 8 2 4.62 20.09 16.55 11.4 1 9.796 5.041 Constant Power Discharge Characteristics: W (25 oC) F.V/Time 5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR 20HR 9.6 V 3317 241 6 1996 1284 751.1 458.4 3 19.9 262.6 215.1 148.3 12 5.5 69.26 10.0V 3251 234 2 1964 1269 749.3 456.0 3 20.0 262.3 214.6 147.6 12 4.7 68.06 10.2V 3214 228 0 1941 1260 743.5 453.3 3 18.6 261.7 213.9 146.6 12 3.6 66.80 10.5V 2926 212 3 1852 1230 736.8 450.0 3 17.4 259.3 211.3 145.4 12 2.4 65.54 10.8V 2665 195 7 1712 1179 723.2 444.2 3 08.7 253.4 207.5 143.0 12 1.2 64.28 11.1V 2341 177 0 1541 1108 692.3 427.7 2 95.4 241.1 198.6 136.9 11 7.6 60.50 All mentioned values are average values. RA12-100AD 12V100Ah Storage characteristic Li fe ch ar ac ter ist ics of cy cl ic us e 100 120 Su ppleme ntary ch arge required (Ca rry ou t suppleme ntary ch arge before us e if 100% ca pacity is requires) 0℃ Capacity (%) Capacity(%) 100 80 60 100% 80% D.O.D D.O.D 50% D.O.D 30% D.O.D 15% D.O.D 40 80 10℃ Su ppleme ntary ch arge required before us e. This su ppleme ntary ch arge wi ll help to recover the ca pacity an d sh ould be ma de as ea rly as po ssible. 60 20℃ 40 30℃ 40℃ Su ppleme ntary ch arge ma y of ten fail to recover the ca pacity. The ba ttery sh ould ne ver be left standing till this st ate is reached 20 20 0 300 0 600 900 1200 1500 4 2 1800 6 Number of Cycle(Times) Charge characteristic curve for cyclic use 15 7.5 Discharge characteristic curve 5.0 0.24 120 4.3 12 6.0 80 ① Discharge 100%(0.05CA×20h) 50%(0.05CA×10h) ② Charge Chcrge Voltage2.275V/C Charge Current0.1CA ③ Temperature 25℃ 4.0 11 5.5 3.7 10 5.0 3.3 60 40 0.16 0.12 0.08 T erm inal V oltage (V ) 13 6.5 13 6.5 4.3 12 6.0 4.0 11 5.5 3.7 0.20 100 Chcrge Voltage C h a rg e C u rre n t (C A ) 4.7 C h a rg e V o lu m e (% ) C h a rg e V o lta g e ( V ) Chcrge Volume 14 7.0 Su ppleme ntary ch arge an d st orage guidelines 8 10 12 14 16 18 20 22 24 Storage Time (months) 0.05C 0.16C 0.093C 10 5.0 3.3 9 4.5 3.0 0.35C 0.62C 3C 20 0.04 0 0 1C Charge Current 9 4.5 3.0 0 2 4 6 8 0.6 1.2 3 6 12 30 1 2 10 12 14 16 18 20 24 28 5 10 20 24 Hr min Discharge Time Charge Time(h) Capacity Factors With Different Temperature Battery Type -20℃ -10℃ 0℃ 5℃ 10℃ 20℃ 25℃ 30℃ 40℃ 45℃ GEL 6V&12V Battery 2V 50% 70% 83% 85% 90% 98% 100% 102% 104% 105% 60% 75% 85% 88% 92% 99% 100% 103% 105% 106% AGM 6V&12V Battery 2V 46% 66% 76% 83% 90% 98% 100% 103% 107% 109% 55% 70% 80% 85% 92% 99% 100% 104% 108% 110% Maintenance & Cautions Discharge Current VS. Discharge Voltage Final Discharge Voltage V/cell 1.75V Discharge Current (A) (A)≤0.2C 1.60V 1.70V Cycle service ※ Avoid battery over discharge, especially battery sereis connection use. 0.2C<(A)<1.0C (A)≥1.0C ※ Charged with recommend voltage, ensure battery can be full recharged. In general, recharge capacity should be 1.1-1.15 times discharge capacity. Charge the batteries at least once every six months, o if they are stored at 25 C. ※ Effect of temperature on cycle charge voltage: -4mV/℃/Cell. Charging Method: ※ There are a number of factors that will affect the length of cyclic service. Constant Voltage -0.2Cx2h+2.4~2.45V/Cellx24h,Max. Current 0.3CA Constant Current -0.2Cx2h+0.1CAx12h discharge rate, and the manner in which the battery is recharged. Fast -0.2Cx2h+0.3CAx4.0h Generally specking, the most important factors is depth of discharge. SHEN ZHEN RITAR POWER CO.,LTD. URL:www.ritarpower.com The most significant are depth of discharge, ambient temperature, Address: Rm405,Tower C, Huahan Building,Langshan Rd16, Nanshan District, ShenZhen, 518057, China Tel:+86-755-33981668 Fax:86-755-8347-5180 2011- Version 1
© Copyright 2024