Circuit Breakers Energy Management & Arc Flash Mitigating Solutions Larry Badillo Sales Executive Electric League – Oct 2014 Schneider Electric - Partners Business Unit- 2013 1 PowerPact with Micrologic Circuit Breakers Direct access to energy management L-frame 70- 600A J-frame 70- 250A H-frame 15- 150A New-generation circuit breakers with industry leading performance, measurements and protection in small distribution circuits as low as 15A Smart: A meter in every breaker Safe: Combine safety and performance Simple: Easy to select, install, and use Schneider Electric - Partners Business Unit- 2013 2 Advantages of Electronic Trip Circuit Breakers Direct Access to Energy Management ● System Flexibility ● Adjustable protection settings shapes profile of trip curve to fit each load (enable potential for Selective coordination) ● Zone selective interlocking allows coordination of short-time and ground fault ● Easily modified configurations and functionality for changing customer needs Schneider Electric - Partners Business Unit- 2013 3 PowerPact Breakers TM with Micrologic TM Circuit Direct Access to Energy Management Choose the right trip model for each application… H, J, and L Standard Ammeter Standard Ammeter Energy Frame (15 – 600A) P and R Energy(E) Power Harmonic Frame (up to 3000A) Adj. Protections True RMS Thermal Imaging Current Meter LCD Screen Power & Energy Meter kWh ZSI Adv. Relay Protections Frequency Basic Harmonics Power Factor ZSI-Zone Selective Interlocking Schneider Electric - Partners Business Unit- 2013 4 PowerPact H, J, and L Frame with Micrologic flexible and efficient ● LV circuit breaker ( 600 V) ● Fixed, I-line, draw-out or plug-in ● 3 frames, 6 ratings ● H-frame: 60/100/150 A: 3P ● J-frame: 250 A: 3P ● L-frame: 400/600 A: 3P ● 5 performance levels: ● 18, 35, 65, 100, 200 kA @ 480 V ratings ● Accessories and auxiliaries Plug-in base Fixed Available NOW in LV equipment I-line Draw-out ● Accepts same accessories as thermal magnetic PowerPact range ● Plus, new and innovative options for communications, status indication and monitoring Schneider Electric - Partners Business Unit- 2013 5 Micrologic with integrated measurement & communication ● Micrologic 5 and Micrologic 6 (available for H/J frame trips and 400/600A L-frame trips) ● incorporating measurement ● Built-in LCD display unit ● Measurement A: Ammeter ● Measurement E: Energy and Ammeter ● Micrologic 5 (LSI) includes five adjustments ●LT pickup and delay ●ST pickup and delay ●Instantaneous ● Micrologic 6 (LSIG) adds ground fault equipment protection – pickup and delay adjustments ● Capability for front display module ● Optional remote display unit for Micrologic 5/6 ● Communication with Modbus ● Optional communication module available Schneider Electric - Partners Business Unit- 2013 6 Arc Flash Mitigation Solutions Schneider Electric - Partners Business Unit- 2013 7 Who is adopting NEC 2014 right now? NFPA 70E 2014 Schneider Electric - Partners Business Unit- 2013 8 ArcBlok™ Technology Phase to Phase & Phase to Ground Isolation Cluster Shields Arc Transfer Maximum Heat Transfer Cradle Barriers Arc Ventilation Schneider Electric - Partners Business Unit- 2013 9 Without ArcBlokTM Photos (1 shot) at 65 kAIR @ 480 Vac Schneider Electric - Partners Business Unit- 2013 10 With ArcBlokTM (1 shot) at 65 kAIR @ 480 Vac Schneider Electric - Partners Business Unit- 2013 11 NW/NT Remote Racking Operator -Rack breaker in or out while bus is energized -Operator is at a safe distance Schneider Electric - Partners Business Unit- 2013 12 Remote Open/Close/Charge -Push Button Station -Operator is at a safe distance Schneider Electric - Partners Business Unit- 2013 13 Alternate Maintenance Switch -Two modes of protection -Eliminates short time delay of circuit breaker Schneider Electric - Partners Business Unit- 2013 14
© Copyright 2024