Circuit Breakers – Are You Protected? • Advancements over last 10 years • Safety Influences • Governing Codes and Standards Influences Confidential & Preliminary Circuit Breaker Advancements • Global Application • Modular and Flexible • Easy to Use • Drop in Accessories Confidential & Preliminary Siemens VL: Space Saving The VL 250A Frame is 40% Smaller than our traditional Sentron breakers… …and 8% smaller than our competitors newer breaker FD FG Compact frame sizes allow for reductions in equipment size and cost Siemens VL: Modular and Cost Saving Fully interchangeable trip units promote quick and easy upgrades from Thermal-Magnetic to Electronic Trip Units Siemens VL: Drop in Accessories • Pockets in cover housing isolate internal accessories from main contacts • “Click in place” components in every module Safety Ss Arc Fault One-Pole Combination AFCI Two-Pole Combination AFCI Dual Function AFCI Intelli-Arc Diagnostic Tool © Siemens AG 2007 - Änderungen vorbehalten Why focus on AFCI? It’s all about safety U.S. Fire Administration annual estimates: 67,800 fires 485 deaths 2,300 injuries $868 million in property losses It’s required NEC 2005 – requires combination arc faults on bedroom circuits NEC 2008 – requires combination arc faults on all dwelling areas NEC 2014 – requires both arc fault and ground fault protection on kitchen and laundry circuits Flow Goods / Channel Marketing LEDs If top LED lights up: arc fault If both LEDs light up: line-to-ground arcing If no LEDs light up: short circuit or overload Flow Goods / Channel Marketing CAFCI Single Pole Size Difference Flow Goods / Channel Marketing 2-Pole AFCI Why focus on 2-Pole AFCI? Exclusive product Savings opportunity for customer (less wire with “shared neutral”) Flow Goods / Channel Marketing Dual Function AFCI Combines AFCI and GF in one device Effective June 29, 2015 – UL 943 Auto-Monitoring (Self-Test) End of Life (Lockout) INCLUDED NOW! Flow Goods / Channel Marketing Intelli-ArcTM Diagnostic Tool Flow Goods / Channel Marketing BUT, doesn’t a tester already exist? Intelli-Arc is NOT a TESTER! Diagnoses the cause of an undesired AFCI trip Saves your contractors time and money! This is NOT a TESTER either May or may not make an AFCI trip Can only produce limited simulated arcs Many which “look” like household appliances to an AFCI Not endorsed by UL or any NEMA manufacturer The push to test button remains the ONLY way to test whether or not an AFCI is functioning properly Flow Goods / Channel Marketing Time Current Curves Sample Flow Goods / Channel Marketing Typical Condition 2000A Main, 800A Distribution, 200A Panel, 20A Branch WL JD A NGB 20 A WL 800 A Flow Goods / Channel Marketing Typical Condition Flow Goods / Channel Marketing Let’s fix the problem with fuses! Bussmann J Class 100A Low Peak Flow Goods / Channel Marketing Possible Solution Bussmann J Class 100A Low Peak No overlap Flow Goods / Channel Marketing Arc Flash Discussion • NEC2014 – Article 240.87 Arc Energy Reduction • 1) Zone-Selective Interlocking • 2) Differential Relaying • 3) Energy reducing maintenance switch/local indicator • 4) Energy reducing active arc flash mitigation system • 5) An approved equivalent means • • Mitigation Avoidance Arc Flash Discussion Arc Flash Discussion Arc Flash Discussion Arc Flash Discussion Arc Flash Discussion Competitive ARMS feature Arc Flash Discussion Arc Flash Discussion Arc Flash Discussion Q&A? Arc Flash Discussion Arc Flash Discussion http://www.missioncriticalmagazine.com/articles/86855-not-all-low-voltage-switchgear-is-created-equal Arc Flash Discussion
© Copyright 2024